W912HN-16-R-0008.PDF
PDF 6 MB Posted
- Attached to
- Company Operations Facilities (COF) & Special Operations Forces (SOF) at Hunter Army Airfield, GA
- Solicitation number
- W912HN-16-R-0008
About this file
Drawings Amd 3
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP_Amd_11.pdf | ||
| 16R08.pdf | ||
| 16R08.pdf | ||
| amd10.pdf | ||
| 16R08.pdf | ||
| amd9.pdf | ||
| 16R08.pdf | ||
| amd8.pdf | ||
| 16R08.pdf | ||
| amd7.pdf | ||
| amd6_.pdf | ||
| 16R08.pdf | ||
| 16R08.pdf | ||
| amd5.pdf | ||
| 16R08.pdf | ||
| amd4.pdf | ||
| amd3.pdf | ||
| Amd_0002.pdf | ||
| Amd_1.doc | DOC document | |
| 16R08_Ph1.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TITLEDGN FILESHEET NO.PLATE NO. PLATE NO. SHEET NO. DGN FILE TITLE
US Army Corps of Engineers
Savannah District
FY-15, (PN 57442)
FORT STEWART, GEORGIA
SOF COMPANY OPERATIONS FACILITY
A-101
SECTION OR DETAIL
IDENTIFICATION NUMBER
PLATE NUMBER ON WHICH
SECTION OR DETAIL IS SHOWN
VIEW SECTION
PLATE NUMBER ON WHICH
ELEVATION IS SHOWN
ELEVATION
IDENTIFICATION NUMBER
ELEVATION SYMBOL
SYMBOL WHERE SECTION IS TAKEN
SECTION/DETAIL
TITLE WHERE SECTION IS SHOWN
A-101
SIM
A-101
SIM
SECTION SYMBOLS
HUNTER ARMY AIRFIELD
HQQC-002
ABBREVIATIONS
HQQC-003 LEGEND
HQQVF101 EXISTING CONDITIONS
HQQVF102
EXISTING CONDITIONS
HQQCS101 SITE PLAN
HQQCS102
SITE PLAN
HQPA-101
FLOOR PLAN
HQQE-001
ELECTRICAL LEGEND
C-002
C-003
CS101
A-101
VF101
VF102
E-001
C-001
G-001
HQQC-001
LOCATION MAP
HQQG-001
COVER SHEET AND INDEX OF DRAWINGS
HQQCU100CU100
CS102
HQPA-201
ELEVATIONS
A-201
ES101 HQQES101
ELECTRICAL SITE PLAN
T-001
TS001
HQQT-001
HQQTS101
COMMUNICATIONS LEGEND
COMMUNICATIONS SITE PLAN
SITE UTILITY PLAN WATER & SEWER
Solicitation Number: W912HN-16-R-0008
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
M T
B
Y
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
C
N
O
S O
L I C
I T
A T
I O
N
N
O
U S
A
R M
Y
C
O R
P
F
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
H
D
I S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
J
L L
S W
T
J L L
K N
A P
P
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
L L
S W
T
J L L
W J K
A
B
C
D
E
F
G
H
I
J
K
O
N
L
P
M
Q
R
S
T
U
W
X
G
G.C.O.
G.V.
GA
GAL
GALV
GD
GEN
GI
GL
GOVT.
GPM
GR
GRND
GRTG
GRVL
GV
GWB
GWT
GYP
GAS
GROUND CLEANOUT
GATE VALVE
GAUGE
GALLON
GALVANIZED
GARBAGE DISPOSER
GENERAL
GALVANIZED IRON
GLASS
GOVERNMENT
GALLONS PER MINUTES
GRADE
GROUND
GRATING
GRAVEL
GAS VALVE
GYPSUM WALLBOARD
GLAZED WALL TILE
GYPSUM
HPW
HR
HSB
HSGYP
HT
HTG
HTR
HW
HWH
HWR
HWRR
HWS
HYD
I OR FE
I.D.
I.P.
IAW
IBC
IC
IE
IES
IESCR
IN
INSUL.
INT
INV
IRH
IS
IRON
INSIDE DIAMETER
IRON PIPE
IN ACCORDANCE WITH
INTERNATIONAL BUILDING CODE
INTERCOM
INVERT ELEVATION
ILLUMINATING ENG. SOCIETY
INTERUPTING ELECTRICAL
SHORT CIRCUIT RATING
INCH
INSULATION
INTERIOR
INVERT
INFRA-RED HEATER
INDUSTRIAL SEWER
JB
JC
JCT
JST
JT
K
KIT
KL
KP
KSF
KSI
KV
KVA
KVAR
KW
KWH
JUNCTION BOX
JANITOR CLOSET
JUNCTION
JOIST
JOINT
KEY
KITCHEN
KEY LOCK
KICK PLATE
KIPS/SQUARE FOOT
KIPS/SQUARE INCH
KILOVOLTS
KILOVOLT AMPERES
KILOVOLT AMPERES REACTIVE
KILOWATTS
KILOWATT HOUR METER
OA
OB WG
OBGL
OBSC
OC
OD
OFF.
OH
OPNG
OPP
OPP. HD.
OPS
OSP
OVSCP
OWS
OUTSIDE AIR
OBSCURE WIRE GLASS
OBSCURE GLASS
OBSCURE
ON CENTERS
OUTSIDE DIMENSION
OFFICE
OVERHEAD
OPENING
OPPOSITE
OPPOSITE HAND
OPERATIONS
OUTSIDE PLANT CABLE
OVERFLOW SCUPPER
OIL WATER SEPARATOR
L
LAU
LAV
LBR
LBS
LD
LDG
LG
LIN
LIS
LLH
LLV
LNDG
LNTL
LONG
LP
LPS
LT
LT. WT.
LTG
LUMEN
LAUNDRY
LAVATORY
LUMBER
POUND
LOAD
LOADING
LENGTH
LINEAR
LAWN IRRIGATION SYSTEM
LONG - LEG HORIZONTAL
LONG - LEG VERTICAL
LANDING
LINTEL
LONGITUDINAL
LOW POINT
LIGHT PROOF SHADE
LIGHT
LIGHT WEIGHT
LIGHTING
POLE
PLASTIC LAMINATE
PRESTRESSED
PUBLIC ADDRESS
PANIC BOLT
PUSH BUTTON STATION
PORTLAND CEMENT CONCRETE
PAVEMENT DRAIN
PERFORATED
PHASE
POINT OF INTERSECTION
POST INDICATOR VALVE
POWER LINE
PLATE
PLASTER
PLATFORM
PLUMBING
PILING
PLYWOOD
PANEL
PANEL BOARD
POLISH
PORCELAIN
POINT OF BEGINNING
POWER POLE
PAIR
PREFABRICATED
PROJECTION
PROPOSED
PARAPET
PRESSURE REGULATING VALVE
POUNDS/SQUARE FOOT
POUNDS/SQUARE INCH
POINT
PAINTED
PARTITION
QUARTER ROUND
QUARRY TILE
QUART
QUARTERS
MANUFACTURING
MANUFACTURE
MOTOR GENERATOR
MANHOLE
MAHOGANY
MINIMUM
METAL LATH
MOULDING
MASONRY OPENING
MONUMENT
MONOLITHIC
MOTOR
MASTIC
METAL THRESHOLD
MOUNTED
MOUNTAIN
MASONRY UNIT
MONITORING WELL
NORTH
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL
MANUFACTURERS' ASSOCATION
NOT IN CONTRACT
NUMBER
NEAR SIDE
MFG
MFR
MG
MH
MHGY
MIN
ML
MLDG
MO
MON
MONO
MOT
MSTC
MT
MTD
MTN
MU
MW
N
NEC
NEMA
NIC
NO.
NS
THOUSAND
MATCHED & BEADED
MACHINE
MASONRY
MATERIAL
MAXIMUM
MEDICINE CABINET
THOUSAND CIRCULAR MILLS
MATCH EXISTING
MECHANICAL
METAL
M
M & B
MACH
MAS
MAT
MAX
MC
MCM
ME
MECH
MET.
V
U.S.
UC
UG
UGE
UH
UIP
UL
UNEX
UNFIN
UNO
UR
UT
UV
V
VB
VC
VCP
VCT
VENT
VERT
VFDU
VOL
VS
VTR
UNITED STATES
UNIT COOLER
UNDERGROUND
UNDERGROUND ELECTRIC
UNIT HEATER
USE IN PLACE
UNDERWRITERS' LABORATORIES
UNEXCAVATED
UNFINISHED
UNLESS NOTED OTHERWISE
URINAL
UTILITY
UNIT VENTILATOR
VOLT
VINYL BASE
VINYL-WALL COVERING
VITRIFIED CLAY PIPE
VINYL COMPOSITION TILE
VENTILATION or VENTILATOR
VERTICAL
VARIABLE FREQUENCY
DRIVE UNIT
VOLUME
VENT STACK
VENT THRU ROOF
Y
T
T.O.
TA
TAB
TAN.
TAP
TBD
TBR&R
TE
TEL
TEMP
TER
TERM
TGL
TH
THERMO
THK
TOC
TOIL.
TOPO
TOS
TP
TTB
TV
TYP
TREAD
TOP OF
TRAINING AREA
TOP AND BOTTOM
TANGENT
WATTAGE TAP
TACK BOARD
TO BE REMOVED AND REPLACED
THICKENED EDGE
TELEPHONE
TEMPERATURE
TERRAZZO
TERMINAL
TOGGLE
THRESHOLD
THERMOSTAT
THICK
TOP OF CONCRETE
TOILET
TOPOGRAPHY
TOP OF STEEL
TEST PIT
TELE TERMINAL BOARD
TELEVISION
TYPICAL
B & B
B.M.
BATT
BD
BDY
BIT
BL
BLDG
BLDG. DIR
BLK
BLKG
BM
BOC
BOF
BOS
BOT
BRCG
BRDG
BRG
BRKT
BT
BTU
BTUH
BALL AND BURLAP
BENCH MARK
BATTEN INSULATION
BOARD
BOUNDARY
BITUMINOUS
BUILDING LINE
BUILDING
BUILDING DIRECTORY
BLOCK
BLOCKING
BEAM
BACK OF CURB
BOTTOM OF FOOTING
BOTTOM OF STEEL
BOTTOM
BRACING
BRIDGING
BEARING
BRACKET
BENT
BRITISH THERMAL UNIT
BTU PER HOUR
P
P. LAM.
P/S
PA
PAN. B
PBS
PCC
PD
PERF
PH or 0
PI
PIV
PL
} or P
PLAS
PLATF
PLBG
PLG
PLY WD
PNL
PNL BD
POL
PORC
POB
PP
PR
PREFAB
PROJ
PROP
PRPT
PRV
PSF
PSI
PT
PTD
PTN
4 RD
Q.T.
QT
QTERS
S
S.D.
S.ST.
S/W
SA
SAF
SB
SCHD
SCP
SCR
SCUT
SD
SDMH
SECT
SECY
SEQ
SFU
SHT
SHTHG
SIM
SL
SP
SPDT
SPEC
SPF
SPH
SPKR
SPL
SQ
SQUAD
SR
SS
SSMH
SSMR
ST
STA
STD
STF
STGR
STL
STN
STOR
STR
STWY
SU
SUB FL
SUSP
SW
SWBD
SYMM
A/C
AB
ABT
AC
ACSR
ACST
ADEM
AFF
AFFF
AFG
AGG
AHU
AI
AIC
AL
ALT
AMP
AP
APPD
APPROX
ARCH
ASPH
ASWG
ATC
AUTO
AVE
AVG
AT
AMPS INTERRUPTING
CAPACITY (SYM RMS)
ANCHOR BOLT
ABOUT
ASPHALTIC CONCRETE
ALUMINUM CONDUCTOR
STEEL REINFORCED
ACOUSTIC
ALABAMA DEPARTMENT OF
ENVIRONMENTAL MANAGEMENT
ABOVE FINISH FLOOR
AQUEOUS FILM-FORMING FOAM
ABOVE FINISH GRADE
AGGREGATE
AIR HANDLING UNIT
AREA INLET
AMPS INTERRUPTING
CAPACITY (SYM RMS)
ALUMINUM
ALTERNATE
AMPERE
ACCESS PANEL
APPROVED
APPROXIMATE
ARCHITECTURAL
ASPHALT
AMERICAN WIRE GAUGE
ACOUSTICAL TILE CEILING
AUTOMATIC
AVENUE
AVERAGE
d
D
D&M
D or DBL
D.C.J.
D.I.
DA
DB
DC
DCJT
DCL
DCW
DEG
DEPR
DEPT
DF
DH
DHWR
DHWS
DIA or ~
DIAG
DIAPH
DIM
DIST
DN
DO
DOIM
DOM
DP
DPST
DR
DS
DTL
DWD
DWG
DWLS
PENNY (as in nail-10d)
DATUM OR DRYER
DRESSED & MATCHED
DOUBLE
DOWELED CONTROL JOINT
DUCTILE IRON
DOUBLE ACTING
DRY BULB
DIRECT CURRENT
DUMMY CONTROL JOINT
DOOR CLOSER
DOMESTIC COLD WATER
DEGREE
DEPRESSION
DEPARTMENT
DRINKING FOUNTAIN
DOUBLE HUNG
DOMESTIC HOT WATER
RETURN
DOMESTIC HOT WATER
SUPPLY
DIAMETER
DIAGONAL
DIAPHRAGM
DIMENSION
DISTRIBUTION
DOWN
DOOR OPENING
DIVISION OF INFORMATION
MANAGEMENT
DOOR OPERATOR MOTOR
DAMPPROOFING
DOUBLE POLE SNGL THROW
DRAIN
DOWN SPOUT
DETAIL
DRINKING WATER DISPENSER
DRAWING
DOWELS
EA
EF
EOC
E.W.C.
EACH
EXHAUST FAN
EDGE OF CURB
ELECTRIC WATER COOLER
EL
ELEC
EM
ENCL
ENG.
ENT
EOC
EP
EQ
EQUIP
ER
EST
EW
E.W.C.
EXC
EXIST
EXP
EXPN
EXT
ELEVATION (GRADE or BLDG)
ELECTRICAL OR ELECTRIC
EMERGENCY
ENCLOSURE
ENGINEERING
ENTRANCE
EDGE OF CURB
EDGE OF PAVEMENT
EQUAL
EQUIPMENT
EXHAUST REGISTER
ESTIMATE
EACH WAY
ELECTRIC WATER COOLER
EXCAVATE
EXISTING
EXPOSED
EXPANSION
EXTERIOR
FAHRENHEIT
FEET PER MINUTE
FAR SIDE OR FULL SIZE
FEDERAL AVIATION ADMINISTRATION
FAN COIL UNIT
FOOT CANDLE
FACING
FLOOR DRAIN OR FIRE DAMPER
FOUNDATION
FIRE EXTINGUISHER CABINET
FINISH FLOOR
FLUSH FLR. CLEAN OUT
FIRE HYDRANT
FIRE HOSE CABINET
FIGURE
FINISH
FIXTURE
FLOOR
FLASHING
FLOORING
FLUORESCENT
FIBER OPTIC CABLE
FIRE PROTECTION
FIRE PROOF
FRAME OR FIRE RATED
FEET OR FINNED TUBE
FOOTING
FURRING
F
F.P.M.
F.S.
FAA
FCU
FC
FCG
FD
FDN
FEC
FF
FFCO
FH
FHC
FIG
FIN.
FIX.
FL
FLASH.
FLG
FLUOR
FOC
FP
FPRF
FR
FT
FTG
FURR'G
H.PT.
H.S.
HB
HBD
HDW
HDR
HTR
HEP
HM
HOA
HP
R
R.D.
R.S.
RA
RAD or R
RB
RC
RC
RCB
RCP
RCVR
RD
RD OR ~
RECP
RECR
REF or RE:
REFR
REG
REINF
REM
REQ'D
REV
RGE
RGH
RM
RMC
ROW
RUB
RISER
ROOF DRAIN
ROOF SCUTTLE
RETURN AIR
RADIUS
RUBBER BASE
RADIATOR CONVECTOR
REMOTE CONTROL
REINFORCED CONCRETE BOX
REINFORCED CONCRETE PIPE
RECEIVER
ROAD
ROUND
RECEPTACLE
RECREATION
REFERENCE
REFRIGERATOR
REGISTER OR REGULAR
REINFORCEMENT
REMOVABLE
REQUIRED
REVISIONS
RANGE
ROUGH
ROOM
RIGID METAL CONDUIT
RIGHT OF WAY
RUBBER
SOUTH
SUPPLY DIFFUSER
STAINLESS STEEL
SIDEWALK
SUPPLY AIR
SUPPLY AIR FAN
SPLASH BLOCK
SCHEDULE
SCUPPER
SCREW
SCUTTLE
STORM DRAIN
STORM DRAIN MANHOLE
SECTION
SECRETARY
SEQUENCE
STRUCTURAL FACING UNIT
SHEET
SHEATHING
SIMILAR
SEISMIC SURVEY
SPACING
SINGLE POLE DBL THROW
SPECIFICATIONS
SOUNDPROOF
SPACE HEATER
SPEAKER
SPECIAL
SQUARE
SQUADRON
SUPPLY REGISTER
SANITARY SEWER
SANITARY SEWER MANHOLE
STRUCTURAL STANDING
SEAM METAL ROOF PANELS
STRAND
STATION
STANDARD
STIFFENER
STRINGER
STEEL
STONE
STORAGE
STRUCTURAL
STAIRWAY
SPARE UNIT
SUB FLOOR
SUSPENDED
SWITCH
SWITCHBOARD
SYMMETRICAL
W
W.E.
W.I.
W/
W/O
WB
WC
WD
WF
WH
WHM
WKS
WL
WP
WPF
WPFG
WRB
WS
WSA
WT
WV
WWF
XFMR
Y.D.
YD
WEST
WATER ELEVATION
WROUGHT IRON
WITH
WITHOUT
WET BULB
WATER CLOSET
WOOD
WIDE FLANGE
WALL HYDRANT
WATT HOUR METER
WORK SHOP
WATER LINE
WEATHER PROOF
WATER PROOF
WATER PROOFING
WARDROBE
WASTE STACK
OR WEATHER STRIPPING
WEAPON STORAGE AREA
WEIGHT
WATER VALVE
WELDED WIRE FABRIC
TRANSFORMER
YARD DRAIN
YARD
HIGH POINT
HIGH STRENGTH
HOSE BIBB
HARDBOARD
HARDWARE
HEADER
HEATER
HORIZONTAL ELLIPTICAL PIPE
HOLLOW METAL
HANDS OFF AUTO
HORSE POWER
HIGH PRESSURE WASHER
HOUR
HIGH STRENGTH BOLT
HIGH-STRENGTH GYPSUM
PLASTER
HEIGHT
HEATING
HEATER
HOT WATER
HOT WATER HEATER
HOT WATER RETURN
HOT WATER RETURN
HOT WATER SUPPLY
HYDRAULIC
CMT
CMU
CNTR
CO
COL
COM
COMB
COMB.
COMM
COMP
COMPF
CONC
CONSTR
CONT.
COR
CORR
COV
CP
CPL
CPS or
CRES
CRG
CRS
CSK
CSO
CT
CTR
CTRL
CTU
CU
CU YD
CUH
CV
CW
CWR
CWRR
CWS
CYL
CERAMIC MOSAIC TILE
CONCRETE MASONRY UNITS
COUNTER
CLEANOUT
COLUMN
COMMON
COMBINATION
COMBUSTION
COMMUNICATIONS
COMPRESSIBLE
COMPOSITION FLOORING
CONCRETE
CONSTRUCTION
CONTINUOUS
CORNER
CORRIDOR
COVERED
REINFORCED CONCRETE PIPE
CEMENT PLASTER
CYCLES PER SECOND
CORROSIVE RESISTANT STEEL
CARRIAGE
COURSE
COUNTERSUNK
COMBINATION SEWER OUTFLOW
CIRCUIT
CENTER
CONTROL
CERAMIC TILE UNGLAZED
CONDENSING UNIT
CUBIC YARDS
CABINET UNIT HEATER
CEILING VENT
COLD WATER
CHILLED WATER RETURN
CHILLED WATER REVERSE
RETURN
CHILLED WATER SUPPLY
CYLINDER
CENTER LINE
CENTER TO CENTER
CURB & GUTTER
CONDUIT (for raceway)
CAST IRON
CORPS OF ENGINEERS
CONTRACTING OFFICER
REPRESENTATIVE
CABINET
CAPACITY
CATCH BASIN
CLOSED CELL SPRAY FOAM INSUL.
COVER ELEVATION
CEMENT
CUBIC FEET PER MINUTE
CORNER GUARD
CURB INLET
CIRCULAR
CONSTRUCTION JOINT
CHECKED
CIRCUIT
CIRCUIT BREAKER
CHAIN LINK FENCE
CEILING
CAULKING
COLUMN
CLOSED
CORRUGATED METAL PIPE
{ or CL
C TO C
C&G
C. or CND
C.I.
C.O.E
C.O.R
CAB
CAP
CB
cc:SPF
CE
CEM
CFM
CG
CI
CIR
CJ
CKD
CKT
CKT BKR
CLF
CLG
CLKG
CLO
CLOS
CMP
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
W
J L L
S W
T
J L L
W J K
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
C
W
W
J L L
S W
T
J L L
W J K
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
L L
S W
T
J L L
W J K
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
C
W
C
C
C
W
J L L
S W
T
J L L
K N
A P
P
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
L L
S W
T
J L L
W J K
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
WM
WM
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
G
L
BUILDING 821
BUILDING 819
BUILDING 836
BUILDING 837
BUILDING 824
BUILDING 822
BUILDING 823
BUILDING 833
BUILDING 840
BUILDING 834
BUILDING 846
BUILDING 831
WM
BUILDING 817
FH 800-1
FH 821-1
BUILDING 827
BUILDING 820
P
I
V
PLAN NORTH
SCALE:
60' 120'60
1"=60'
NOTE:
1. CONNECT TO EXISTING 6" WATER MAIN WITH TAPPING SLEEVE AND GATE VALVE.
2. PROPOSED NEW FIRE HYDRANT LOCATION. AT LEAST ONE FIRE HYDRANT SHALL
BE LOCATED WITHIN 100 FEET OF THE FIRE DEPARTMENT CONNECTION (FDC).
FIRE HYDRANT LOCATIONS SHALL BE IN ACCORDANCE WITH UFC 3-600-01.
3. PROPOSED FIRE WATER MAIN. FIRE WATER MAIN IS TO INCLUDE A POST
INDICATOR VALVE (PIV) LOCATED AND INSTALLED IN ACCORDANCE WITH NFPA
24. THE PIV SHALL INCLUDE A TAMPER SWITCH.
4. PROPOSED WATER SERVICE LINE TO BUILDING MECHANICAL ROOM LOCATION.
CONTRACTOR IS TO PROVIDE AN APPROPRIATELY SIZED GATE VALVE AND
REMOTE READ METER.
5. GRAVITY SEWER LINE TO NEW LIFT STATION LOCATION. A MINIMUM SIZE OF 6" IS
TO BE USED FOR THE GRAVITY SEWER SERVICE LATERAL.
6. NEW LIFT STATION SHALL BE A MINIMUM OF A DUPLEX PUMPING SYSTEM
RUNNING ALTERNATELY. EACH PUMP SHALL BE CAPABLE OF PRODUCING
REQUIRED HEAD AND PEAK FLOW INDEPENDENT OF ACCOMPANYING PUMP.
7. PROPOSED NEW FORCE MAIN LINE LOCATION.
8. CONNECT NEW FORCE MAIN TO MANHOLE. CONTRACTOR IS RESPONSIBLE FOR
DETERMINING IF EXISTING MANHOLE WILL HAVE SUFFICIENT CAPACITY TO
HANDLE FLOWS GENERATED FROM THE SOF COMPANY OPERATIONS FACILITY.
8.1. FOR BIDDING PURPOSES ONLY, THE CONTRACTOR IS TO ASSUME 35 GPM
FLOW INTO THE CONNECTING MANHOLE FROM THE EXISTING 2" PVC FM.
8.2. FOR BIDDING PURPOSES ONLY, THE CONTRACTOR IS TO ASSUME THE 8"
PIPE EXITING THE MANHOLE IS LAID ON MINIMUM SLOPE.
8.3. THE CONTRACTOR SHALL FIELD VERIFY THE PUMPING RATE AT THE
UPSTREAM LIFT STATIONS THAT DISCHARGE INTO THE CONNECTING
MANHOLE FOR DESIGN PURPOSES.
8.4. IN THE EVENT THE MANHOLE DOES NOT HAVE SUFFICIENT CAPACITY TO
MEET THE CALCULATED DISCHARGE QUANTITIES FROM THE SOF COF, THE
CONTRACTOR SHALL EXTEND THE FORCE MAIN DOWNSTREAM TO THE
NEXT ADJACENT MANHOLE UNTIL ADEQUATE CAPACITY IS FOUND.
LEGEND
PROPOSED NEW WATER MAIN/SERVICE LINE ROUTE, TYP
PROPOSED NEW FORCE MAIN ROUTE, TYP
NEW FIRE HYDRANT
NEW LIFT STATION
NOTE, TYP.
POST INDICATOR VALVE
EXISTING FIRE HYDRANT
VALVE AND VALVE BOX
WATER METER
GENERAL NOTE:
THE WATER AND SEWER LAYOUT SUGGESTED AREAS AS SHOWN HEREIN
ARE FOR PLANNING AND COST ESTIMATING PURPOSES ONLY. THE
DESIGN/BUILD CONTRACTOR MAY USE THESE PROPOSED SUGGESTED
AREA ROUTES AS GUIDES IN THEIR DESIGN, BUT THE FINAL ROUTES OF
THESES UTILITIES SHALL BE BASED UPON THEIR DESIGN RESULTS.
M E
C
I I
M E
C
I I
J W
F
C W
B
PIV
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N O
8" VC
2" PVC FM
130.28 SF
BH 3
132.60 SF
BH 2
200.07 SF
BH 1
133.00 SF
BH 4
135.38 SF
BH 5
552.61 SF
WAITING
616.16 SF
ADMIN /
RECEPTION
92.50 SF
OFFICE
92.50 SF
OFFICE
1446.97 SF
MED OPS
88.13 SF
RESTRM
281.89 SF
BH WAITING
190.00 SF
EXAM 1
186.67 SF
EXAM 2
88.13 SF
SCREEN
201.74 SF
EXAM 3
140.97 SF
PHARM / STOR
140.97 SF
SCREENING
1523.83 SF
PT
140.93 SF
OFFICE
140.93 SF
OFFICE
188.23 SF
HYDRO THPY
2367.08 SF
READINESS
MODULE
614.42 SF
MECH
109.50 SF
FIRE
182.50 SF
ELEC
152.50 SF
MEN
1234.83 SF
MED STORAGE
152.50 SF
WOMEN
654.63 SF
MEN'S
RESTROOMS /
SHOWER
414.80 SF
WOMEN'S
RESTROOM /
SHOWER
44.00 SF
JANITOR
1149.71 SF
CLASSROOM
492.80 SF
SUPPLY /
STORAGE
123.85 SF
1SG
212.86 SF
COMMAND
133.77 SF
XO
740.97 SF
OP / NCO
131.04 SF
PLT SGT
131.04 SF
NCOIC
150.48 SF
OFFICE
1108.50 SF
OPEN OFFICE
110.61 SF
S6
2232.64 SF
ASD STORAGE
1531.57 SF
CBRN STORAGE
190.42 SF
CBRN
OFFICE
132.08 SF
SIPR / NIPR
COMM
0'-
0"
250'-0"
B B
B
B
E E E
B
B
B B
B
BB
A-2013 A-201
A-201
A-201
13'-11 1/2"5'-0"14'-3"20'-0"5'-0"14'-7"59'-7"20'-9 1/2"13'-11 1/2"35'-0"14'-7"12'-1"13'-11 1/2"
'-3
9'-
7"
'-4
7'- 0"
'-1
1/
2"
'-1
1/ 2"
'-7
9'-
3"
11'-11 1/2"
25'-5" 39'-1" 32'-10" 17'-0"
'-1
/2
6'-0"
6'- 0"
'-9
/2
'-2
/2
14'-5" 10'-0"
'-5
/2
33'-8" 6'-0" 10'-0"
'-3
'-6
53'-6" 31'-10"
'-4
'-0
'-7
51'-1 1/2"
'-0
9'-3" 9'-3"
26'-5"6'- 0"
6'-0"
'-5
'-7
17'-10 1/2"
12'-1"
'-4
9'-
6" 9'-
1/
2"
7'- 0"
'-1
1/
2" 9'-
8" 9'-
8"
5'-0"5'-0"22 '-0
/2
12'-2" 12'-2" 16'-3"
'-7
LEGEND:
B = BADGE READER
E = EXIT ONLY DOOR
B
PLATE
REFERENCE
NUMBER
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
D
AT
E :
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
SHEET OF
1/
/2
9:
:3
AM
SO
F
C O M
P A
NY
O
PE
RA
TI
O
NS
F
AC
IL
IT
Y
HU
N T
ER
A
RM
Y
AI
RF
I E
LD
(P
N
2)
JA
N
U
AR
Y
W
2H N
-1 6-
R -0
Mobile District
C .G
AN
T
EN
-D
A
C . A
SH
LE
Y
H Q
PA
-1
.D
W G
1-
-0
A-101
SA
VA
N N
AH
D
IS
TR
IC
T
FL
O
O R
P
LA
N
FO
R
T S T
EW
AR
T , G
E O R
G
IA
cr d a m c-
A L
- A
- 1
- X
XX
FLOOR PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
SPLIT FACE CMU (TYP.)
BRICK VENEER (TYP.)
4" PRECAST SILLS / BAND (TYP.)
TRANSLUCENT WINDOWS
(TYP. ALL WINDOWS)
STANDING SEAM MTL. ROOF (TYP.)
ROOF = +12' - 0"
FINISH FLOOR = 0' - 0"2'-
8"
SPLIT FACE CMU (TYP.)
BRICK VENEER (TYP.)4" PRECAST SILLS / BAND (TYP.)
TRANSLUCENT WINDOWS
(TYP. ALL WINDOWS)
STANDING SEAM MTL. ROOF (TYP.)
ROOF = +12' - 0"
FINISH FLOOR = 0' - 0"2'-
8"
SPLIT FACE CMU (TYP.)
BRICK VENEER (TYP.)
4" PRECAST SILLS / BAND (TYP.)
TRANSLUCENT WINDOWS
(TYP. ALL WINDOWS)
STANDING SEAM MTL. ROOF (TYP.)
ROOF = +12' - 0"
FINISH FLOOR = 0' - 0"
METAL CANOPY ROOF
2'- 8"
SPLIT FACE CMU (TYP.)
BRICK VENEER (TYP.)4" PRECAST SILLS / BAND (TYP.)
TRANSLUCENT WINDOWS
(TYP. ALL WINDOWS)
STANDING SEAM MTL. ROOF (TYP.)
2'- 8"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
D
AT
E :
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S C
KD
B
Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
SHEET OF
/3
2"
'-0
1/
/2
9:
:4
AM
FO
RT
S
TE
W
AR
T , G
EO
RG
IA
SO
F C O
M P A
NY
O
PE
RA
TI
O
NS
F
AC
IL
IT
Y
HU
N T
ER
A
RM
Y
AI
RF
I E
LD
(P N
2)
JA
N
U
AR
Y
W
2H N
-1 6-
R -0
Mobile District
C . G
AN
T
C . G
AN
T
C . A
SH
LE
Y
H Q
PA
-2
1-
-0
A-201
EL
E V
AT
IO
N S
SA
VA
N N
AH
D
IS
TR
IC
T
C he ck er
3/32" = 1'-0"A-101
4 SOUTH ELEVATION
3/32" = 1'-0"A-101
3 NORTH ELEVATION
3/32" = 1'-0"A-101
2 EAST ELEVATION
3/32" = 1'-0"A-101
1 WEST ELEVATION
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED FLUSH IN FLOOR.
"AV" DENOTES AUDIO/VISUAL OUTLET.
JUNCTION BOX; "F" INDICATES FLOOR MOUNTED, "C" INDICATES
CEILING MTD, "W" INDICATES WALL MOUNTED 48" AFF, UNLESS
NOTED OTHERWISE.
VARIABLE FREQUENCY DRIVE. SIZE AS SHOWN
FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT BASED ON
MANUFACTURERS' RECOMMENDATIONS.
SURFACE MOUNTED PANEL BOARD OR AUTOMATIC TRANSFER SWITCH
AS INDICATED
MOTOR, SIZE AS SHOWN.
250 VOLT, 1-PHASE, 30 AMP RECEPTACLE, (L6-30R)
120 VOLT, 1-PHASE, 30 AMP RECEPTACLE, (L5-30R)
EXISTING ITEMS TO BE REMOVED
EXISTING POLE MOUNTED LIGHTING FIXTURE
NEW POLE MOUNTED LIGHTING FIXTURE
EXISTING UNDERGROUND ELECTRICAL LINE.
EXISTING OVERHEAD ELECTRICAL LINE.
EXISTING UNDERGROUND COMMUNICATION LINE
EXISTING OVERHEAD COMMUNICATION LINE
NEW BOLLARD LIGHT FIXTURE.
480 VOLT, 3-PHASE, 60 AMP RECEPTACLE
250 VOLT, 1-PHASE, 20 AMP RECEPTACLE, (L6-20R)
208 VOLT, 3-PHASE, 30 AMP RECEPTACLE
CORD REEL, MOUNTED TO EXPOSED STRUCTURE OR CEILING.
ELECTRONIC BIRD REPELLER, MOUNTED TO EXPOSED STRUCTURE.
NEW UNDERGROUND PRIMARY, WITH CAP
NEW UNDERGROUND SECONDARY, WITH CAP
NEW UNDERGROUND COMMUNICATIONS
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED, WALL MOUNTING
AT 8' AFF UNLESS NOTED OTHERWISE.
WALL MOUNTED EMERGENCY FIXTURE, LETTER INDICATES
TYPE PER FIXTURE SCHEDULE
3 BUTTON LIGHT SWITCH - HALF LIGHTS, FULL LIGHTS, ALL OFF -
MOUNTED 42" AFF.
2 BUTTON LIGHT SWITCH - ENTRY, ALL OFF - MOUNTED 42" AFF.
WALL MOUNTED OCCUPANCY SENSOR/SWITCH, PASSIVE INFRARED
CEILING MOUNTED OCCUPANCY SENSOR, PASSIVE INFRARED
20 AMP, 277 VOLT TOGGLE SWITCH MOUNTED 42" AFF, "a" CONTROLS
LIGHTS WITH "a" DESIGNATION
LIGHTING CONTACTOR
HVAC VAV BOX POWER, MOUNTED TO EXPOSED STRUCTURE OR CEILING
UNFUSED DISCONNECT SWITCH. SIZE AS SHOWN. NEMA 1 ENCLOSURE
UNLESS NOTED OTHERWISE.
DRY TYPE TRANSFORMER. SIZE AS SHOWN.
NEMA 5-20 QUAD RECEPTACLE MOUNTED 18" AFF UNLESS
NOTED OTHERWISE
NEW TRANSFORMER VAULT, SIZE AS SHOWN.
1P SINGLE POLE
3P 3 POLE
AFF ABOVE FINISHED FLOOR
HP HORSEPOWER
ATS AUTOMATIC TRANSFER SWITCH
EXISTING TAXIWAY LIGHTS, TO BE REMOVED
NEW TAXIWAY SEMIFLUSH LIGHTS, BLUE HALOGEN LAMP
EXISTING TAXIWAY LIGHTS
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 90" AFF
MOTOR RATED SWITCH
5 BUTTON LIGHT SWITCH FOR HANGAR BAY ZONING - 3 ZONES,
ALL ON, ALL OFF, MOUNTED 42" AFF.
LIGHTING DIMMING CONTROL PANEL WITH RELAY CARD
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF UNLESS NOTED
OTHERWISE. (AC INDICATES MOUNTED 6" ABOVE COUNTER, WP
INDICATES WEATHERPROOF, GFI INDICATES GROUND FAULT CIRCUIT
INTERRUPTER, AV DENOTES AUDIO/VISUAL OUTLET, AND 90" INDICATES
90" AFF.)
VACANCY SENSOR/SWITCH
ELECTRICAL METER
NEW GATE CONTROLLER
EXISTING POLE
WALL MOUNTED OCCUPANCY SENSOR/SWITCH, DUAL TECHNOLOGY
HD HEAVY DUTY
A AMPERE
AC 6" ABOVE COUNTER UNLESS OTHERWISE INDICATED
NEW POLE WITH FLASHING RED LIGHTING FIXTURE
NEW ELECTRICAL PANEL
NEW UNDERGROUND EMPTY CONDUIT WITH PULLWIRE AND CAP
L
C
T
A M
B L Y
N
E N
D
E
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
E
P
E
U
P
E
U
P
E
U
P
E U
P
E
U
P
E
U
P
EXISTING
POWER POLE
EXISTING
POWER POLE
E O
P
E X
IS
T
IN
G
N
IG
H T
S T
A L K
E R
W A
Y
U
P
U
P
C
C
C
PROPOSED LOCATION
OF GATE OPERATOR
PROPOSED LOCATION
OF ACCESS CONTROL
PROPOSED LOCATION
OF GATE OPERATOR
PROPOSED LOCATION
OF ACCESS CONTROL
C
C
C
L
C
T
A M
B L Y
N
E N
D
E
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N O
PLAN NORTH
SCALE:
30' 60'30
1"=30'
KEY NOTES:
COMMUNICATION
TELEPHONE BACKBOARD - 48" X 96"
WALL MOUNTED 2 PORT - 1 DATA/ 1 TELEPHONE JACK, 48"
AFF
2 EACH - 4" EMT CONDUIT INTERCONNECTS
OVERHEAD CABLE TRAY 12"X3"D
CATV OUTLET, 90" AFF
COMMUNICATIONS RACK
UNDERFLOOR CABLE TRAY 12"X3"D
12"X3" METAL RACEWAY FROM FALSE CEILING TO RAISED
FLOOR
MODULAR TELEPHONE/DATA JACKS, MOUNTED FLUSH WITH
FLOOR. 2 DATA AND 1 TELEPHONE IN ONE QUAD OUTLET. "AV"
INDICATES AUDIO/VISUAL.
SECURITY SYSTEMS
ABBREVIATIONS
DUAL DATA OUTLET, 18"AFF, UNLESS OTHERWISE INDICATED.
SIPRNET DROP BOX SAFE
CATV BACKBOARD - 48" X 96"
MODULAR TELEPHONE/DATA JACKS IN ONE 4" BOX, 2 DATA AND 1
TELEPHONE PORTS, 18" AFF UNLESS OTHERWISE INDICATED.
"W" INDICATES WALL MOUNTED 48" AFF,
"AC" INDICATES 6" ABOVE COUNTER,
"AV" INDICATES AUDIO/VISUAL OUTLET.
COMCAST AND/OR CENTER LINK PUBLIC PHONE,
2 PORT PHONE OUTLET, MOUNTED 18" AFF UNLESS NOTED
OTHERWISE.
HANGAR STAND WITH CABLE MANAGEMENT SYSTEM.
AUDIO/VISUAL OUTLET, 18" AFF UNLESS NOTED OTHERWISE.
"F" INDICATES FLOOR FLUSH MOUNTED, 90" INDICATES
90"AFF.
EXTERIOR COMMUNICATION
M
A
L
C
T
A M
B L Y
N
E N
D
E
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N
EXISTING COMM
MANHOLE
EXISTING COMM
EQUIPMENT
U
C
U
C
U
C
UC
C
C
C
C
PROPOSED LOCATION
OF GATE OPERATOR
PROPOSED LOCATION
OF ACCESS CONTROL
PROPOSED LOCATION
OF GATE OPERATOR
PROPOSED LOCATION
OF ACCESS CONTROL
C
C
C
L
C
T
A M
B L Y
N
E N
D
E D
D C
W J K
1 2 3 4 5
D
C
B
A
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
D A
T E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
M
Y
C
O R
E
N G
I N
E E
R S
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
C K
D
B
Y
SAVANNAH
US Army Corps of
Engineers ® x
S A
V A
N N
S
T R
I C
T
C A
T E
G O
D
E
P L
A
L E
P L
T
E
N O
PLAN NORTH
SCALE:
30' 60'30
1"=30'
KEY NOTES:
| G-001 COVERSHEET AND INDEX OF DRAWINGS |
| C-001 LOCATION MAP |
| C-002 ABBREVIATIONS |
| C-003 LEGEND |
| VF101 EXISTING CONDITIONS |
| VF102 EXISTING CONDITIONS |
| CS101 SITE PLAN |
| CS102 SITE PLAN |
| CU100 SITE UTILITY PLAN WATER & SEWER |
| A-101 FLOOR PLAN |
| A-201 ELEVATIONS |
| E-001 ELECTRICAL LEGEND |
| ES101 ELECTRICAL SITE PLAN |
| T-001 COMMUNICATIONS LEGEND |
| TS101 COMMUNICATIONS SITE PLAN |
File details come from the government source that posted it. Updated .