Synopsis Modified Apr 15 2009 09-R-0018 McN 10 Unit Rewind.pdf

PDF 19 KB Posted

Attached to
McNary Dam Main Unit Stator Winding Replacement, Umatilla, Oregon
Solicitation number
W912EF-09-R-0018
Issued by

About this file

Synopsis is amended to add information regarding site visit access for foreign nationals and to extend the expected site visit date from approx. 2 weeks after issuance of solicitation to approx. 4 weeks after issuance of solicitation.

View the file

Other files

File Type Posted
Amendment 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003 plans.zip ZIP file
Amend 0003.pdf PDF
Amend 0002 Plans.zip ZIP file
Amend 0002.pdf PDF
Site visit attendance list.pdf PDF
Amend 0001.pdf PDF
Site Visit.pdf PDF
Plans 1 of 4.zip ZIP file
Plans 2 of 4.zip ZIP file
Downloading and viewing drawings.pdf PDF
Plans 3 of 4.zip ZIP file
Solicitation 09-R-0018.pdf PDF
Plans 4 of 4.zip ZIP file
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Synopsis, McNary Main Unit Stator Winding Replacement

Construction Project: Provide all labor, materials, incidentals, and equipment to perform the work required to rewind Main Units 1 through 4 and 7 through 12 at the McNary Lock and Dam Powerhouse. Two complete installations will be accompllshed concurrently within a 6 month period each year for 5 years.

This list is a general summary of the required work and is not all inclusive:

a. Design, manufacture, shop test, and deliver ten complete sets of stator bars and all accessories specified herein.

b. Disassemble and reassemble ten generators.

c. Remove old stator coils on ten units.

d. Install and test ten new stator windings and accessories specified herein.

e. Perform special field tests on one unit.

f. Remove the old turbine shaft sleeves and install the new Contractor-furnished shaft sleeves on ten units.

g. Furnish, install, and test new bourdon tube-style switches, temperature read-outs and automatic control of unit heaters for ten units.

h. Remove and dispose of the existing rotating exciter and commutator for ten units. Modify existing shafts or provide a new stub shafts as necessary.

i. Furnish, install, and test new bearing RTD's for ten units.

j. Furnish, install, and test new surface air coolers for ten units.

k. Remove servomotors, bore and hone cylinders, provide new piston rings and bushings, and install.

l. Inspect brake plates on nine units.

m. Remove old brake plates and install G-F brake plates on Main Unit 11.

n. Clean and inspect all bearings for ten units.

o. Replace high-pressure oil injection system components for ten units.

p. Perform all work required to comply with the site operations, environmental protection, and safety and health provisions as specified herein.

q. Furnish spare parts.

r. At the option of the Government, restack one stator core using the Government-furnished laminations and furnish one new spare core.

s. At the option of the Government, perform Phase 2 inspections on the thrust bearings.

t. At the option of the Government, prepare Government-furnished spare bearings for installation.

u. At the option of the Government, refurbish the generator and turbine bearings.

Site of the work is Umatilla County, Oregon. Period of performance is stated above. Solicitation No.

W912EF-09-R-0018 will be posted to the FBO website on or about March 9, 2009. Proposals will be due no sooner than 30 calendar days after actual solicitation issuance date. Important Note: The FedBizOpps Response Date listed elsewhere in this synopsis is for FedBizOpps archive purposes only. It has NO relation to the actual bid opening date. The proposal closing date will be contained in the solicitation and any solicitation amendments that may be issued. A site visit will be offered approximately 4 weeks after the solicitation is made available to bidders. See solicitation for details about the site visit. ACCESS FOR FOREIGN NATIONALS: Security clearance for foreign nationals to attend a site visit requires a minimum of 4 weeks. Please contact the Emergency Management Office/District Security Office at 509/527-7362 to request clearance. Foreign nationals must have received clearance prior to being granted access to the project site.

Solicitation is open to both large and small business concerns. NAICS code for this project is 237990, and the small business size standard is $33,500,000 average annual receipts. Estimated magnitude of construction is more than $10,000,000. When available, the solicitation documents for this project will be available via FedBizOpps.gov https://www.fbo.gov NO CD's OR HARD COPIES WILL BE AVAILABLE. Offerors are responsible for checking the referenced page for any update(s) to the Notice. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the document posted at the referenced website. To obtain automatic notifications of updates to this solicitation, you MUST log in to FedBizOpps.gov and add the solicitation to your Watchlist. If you would like to list your firm so others can see you are an interested vendor, you must click the Add Me To Interested Vendors button in the listing for this solicitation on FedBizOpps.gov.

File details come from the government source that posted it. Updated .