AE601.pdf

PDF 156 KB Posted

Attached to
KC-46A Body Tanks Storage Federal contract opportunity
Solicitation number
W912DS18B0020
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

Drawing: AE601

View the file

Other files for this federal contract opportunity

Other files attached to KC-46A Body Tanks Storage, newest first.
File Type Posted
Bid_Abstract.pdf PDF
Amendment_0006.pdf PDF
Amendment__0005.pdf PDF
Amendment_0004.pdf PDF
Appendix_A_-_B1837_As-Builds.pdf PDF
Appendix_C_-_JB_MDL_Soil_Contamination.pdf PDF
Appendix_A_-_B1837_As-Builds.pdf PDF
Amendment_3_-_KC46_Body_Tank_Storage_-_Plans.pdf PDF
Amendment_3_-_KC46_Body_Tank_Storage_-_Specs.pdf PDF
Appendix_B_-_Burlington_Co_Exemption_Notice_Bldg_1837.pdf PDF
Amendment_0003_SF-30.pdf_Final.pdf PDF
Amendment_0002.pdf PDF
Site_Visit.pdf PDF
Amendment_0001_final.pdf PDF
Amendment_0001.pdf PDF
W912DS18B0020.pdf PDF
Package_2_-_JB_MDL_-_Fuel_Body_Tanks_-_Specifications.pdf PDF
Package_3_-_JB_MDL_-_Fuel_Body_Tanks_-_CID.pdf PDF
Package_1_-_JB_MDL_-_Fuel_Body_Tanks_-_Plans.pdf PDF
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D O

O R

H

EI

G H

T

DOOR WIDTH

SFX STEEL, EXTERIOR

D O

O R

H

EI

G H

T

DOOR WIDTH

RDX ROLLING DOOR, EXTERIOR

RDD ROLLING DOOR, 45 MIN FR

DOOR TYPES

SFD STEEL, 45 MIN FR

S2 STEEL

2" D

O O

R H

EI

G

H T

2" 2"DOOR WIDTH

FRAME TYPES

PRECAST CONCRETE

WALL PANEL

HOLLOW METAL

FRAME ANCHOR

DOOR AS

SCHEDULED

STEEL DOOR FRAME

SEALANT ON BOTH SIDES

2"

PRECAST

CONCRETE WALL

PANEL

HOLLOW METAL

FRAME ANCHOR

DOOR AS

SCHEDULED

STEEL DOOR FRAME

SEALANT ON BOTH

SIDES2"

EXP EXPOSED TO STRUCTURE

PT PAINT

SC SEALED CONCRETE

ABBREVIATION LEGEND

2" INSULATED

METAL WALL PANEL

(R-9.75 c.i. MIN)

METAL PANEL

TRIM

STEEL GIRT RE.

STRUCTURAL

OVERHEAD

COILING

DOOR HOOD

PREFINISHED

METAL FLASHING

BACKER ROD AND

SEALANT

VERTICAL STEEL

CHANNELS LOCATED

BETWEEN HORIZONTAL

WALL GIRTS AS

REQUIRED PER DOOR

MANUFACTURER'S

INSTRUCTIONS

OVERHEAD

COILING DOOR

JAMBS

OVERHEAD

COILING DOOR

1'-5"

1' -5

1" PREFINISHED

METAL LINER

PANEL

116'-0"

1/4" STEEL PLATE

STRUCTURAL

FRAMING

1. ALL EXPOSED CMU BLOCK, METAL WALL PANELS,

AND STRUCTURE TO BE PAINTED (PT1).

FINISH SCHEDULE NOTES

A. ALL DOOR FRAMES ARE TO BE PAINTED (PT2).

GENERAL NOTES

PRECAST

CONCRETE

PANEL

INSULATED

OVERHEAD

COILING DOOR

STEEL ANGLE

JAMB GUIDES

W/WEATHER STRIP

STEEL ANGLE

PAINTED

EXISTING PRECAST

CONCRETE PANEL

8" CMU

(1 HOUR RATED WALL)

GROUT FILL

STEEL "C" CHANNEL

OVERHEAD

COILING DOOR

FIRE RATED

STEEL ANGLE JAMBS

GUIDES W/

4" EXPANSION

JOINT

1/8" BENT STEEL

PLATE

4"

STRUCTURAL

FRAMING

7 5/8"

OVERHEAD

COILING DOOR

HOOD

FIRE STOPPING

8" CMU BOND

BEAM, TYP.

EXISTING METAL

WALL PANEL

1' -5

BREAK METAL,

PAINTED

2" EXPANSION

JOINT

STEEL FRAMING,

HSS8x6x3/8

PAINTED

STEEL ANGLE

L5x3x5/16

EXISTING

WALL GIRT

116'-0"

STEEL FRAMING,

PAINTEDINSULATED

OVERHEAD

COILING DOOR

1'-5"

STRUCTURAL

FRAMING

DOOR - SEE SCHEDULE

FOR TYPE AND SWING

SEALANT

BOTH SIDES

8" CMU

3/8" FLAT HEAD

COUNTERSUNK MACHINE

BOLTS AT 24" O.C.. VERT

HOLLOW METAL

FRAME - SEE

SCHEDULE EXISTING

CONCRETE WALL

FIRE STOPPING

2"

4" EXPANSION

JOINT

4"

BENT STEEL PLATE

2"

NOTE: FIRE STOPPING AND

BENT PLATE TO BE INSTALLED

CONTINOUS AROUND THE

PERIMETER OF THE OPENING.

1 EQ5 3/4"EQ

HOLLOW METAL

FRAME - SEE

SCHEDULE

CONT SEALANT

BOTH SIDES

HOLLOW METAL

DOOR - SEE

SCHEDULE

2"

GROUT FILL

EXISTING

CONCRETE WALL

FIRE STOPPING

BENT STEEL

PLATE

4"

8" CMU BOND BEAM

4" EXPANSION

JOINT

DOOR - SEE

SCHEDULE

FOR TYPE AND

SWING VINYL TRANSITION

MOLDING

SEALED CONCRETE

DOOR FRAME

BEYOND

DOOR LOCATION

SEALED

CONCRETE

OF DOORCL

K C

-4 6A

A D

D

TO

B

FO

R B

O D

Y

TA

N K

S S

TO

R

A G

E P

R O

JE

C

T N

U M

B E

R

P

TF

L

Jo in tB as e M cG ui re -D ix -L ak eh ur st

,N ew

Je rs ey

PO

ND

-F

SB

Jo int

Ve ntu re

Pa rkw ay

La ne

,S uit e5

Pe ac htr ee

Co rn er s, GA

Ph on e:

8.3

.77 ww w.

po nd co .co m

M

AY

N

YD

A/ E

B O

R D

ER

FI

LE

N

AM

E:

S ub m itt ed by

P lo tD at e:

FS

B

A N

S

ID

U .S

.A R

M Y

E N

G

IN

E

ER

D

IS

TR

IC

T N

E W

YO

R

K ht tp w w w .n an .u sa ce

.a rm y.

m il

FS

B

- W

4D

S O

LI

C

IT

A

TI

O

N N

O

FI

LE

N A

M E

D W

N

BY

C

KD

BY

D

ES

IG

N

ED

B

Y:

D

AT

E:

S

IZ

E

S U

B M

IT

TE

D B

Y:

P

LO

T D

AT

E:

C O

N

TR

AC

T

N O

P

LO

TT

ED

B Y:

US Army Corps of Engineers

New York District

D

ES

C R

IP

TI

O N

M

AR

K A

PP

R

D

AT

E

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A

PP

R

D

2 3

C

4 5

A

B

SHEET

REFERENCE

NUMBER

0 1"

THIS BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS

SHEET, ADJUST SCALES

ACCORDINGLY

xx xx c-xx x.

dw g

95% SUBMITTAL

C :\U se rs

\m ro

\D oc um en ts \M y R ev it\

0_ Ar ch _m ro .rv t9/

/2

1:

:1

PM

9/

/2

1:

:1

P

M

AE601

SC

H

E D U

LE

S

AN

D

D O

O R

D E T

AI

LS

G M

D

JD

B

JM

I

JD

B

DOOR SCHEDULE

MARK

DOOR

FR STC

FRAME

HARDWARE NOTES

SIZE DOOR

TYPE TYPE

DETAIL

WD HGT THK HEAD JAMB SILL

101A 3'-0" 7'-10" 1 3/4" SFX - - -- S2 7/AE601 4/AE601 715

101B 3'-0" 7'-10" 1 3/4" SFX - - -- S2 7/AE601 4/AE601 715

101C 3'-0" 7'-10" 1 3/4" SFX - - -- S2 2/AE601 4/AE601 715

101D 16'-0" 16'-0" 3/4" RDD 60 MIN -- -- 9/AE601 2/AE601 001

101E 3'-0" 7'-10" 1 3/4" SFD 45 MIN -- S2 3/AE601 6/AE601 1/AE601 715

101F 16'-0" 16'-0" 3/4" RDX - - -- -- 5/AE601 8/AE601 001

ROOM FINISH SCHEDULE

ROOM

NUMBER ROOM NAME

FLOOR

FINISH

BASE

FINISH

WALL FINISHES

CEILING FINISH NOTESNORTH SOUTH EAST WEST

101 BODY TANKS STORAGE SC1 - PT1 PT1 PT1 PT1 EXP, PT3 1

3" 9"6"0

3" = 1'-0"

SCALE 3" = 1'-0"

JAMB DETAIL4

SCALE 3" = 1'-0"

HEAD DETAIL7

SCALE 1 1/2" = 1'-0"

HEAD DETAIL5

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE 3" = 1'-0"

JAMB DETAIL8

SCALE 3" = 1'-0"

JAMB DETAIL2

SCALE 1 1/2" = 1'-0"

HEAD DETAIL9

SCALE 3" = 1'-0"

JAMB DETAIL6 SCALE 3" = 1'-0"

HEAD DETAIL3

SCALE 3" = 1'-0"

DOOR SILL DETAIL1

R

EV

IS

ED

-1 2-

File details come from the government source that posted it.