Amendment_0002_Asbestos_Report.pdf

PDF 15 MB Posted

Attached to
Pershing Barracks Renovation/Modernization, West Point New York Federal contract opportunity
Solicitation number
W912DS-16-B-0010
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

Amendment 0002_Asbestos Report

View the file

Other files for this federal contract opportunity

Other files attached to Pershing Barracks Renovation/Modernization, West Point New York, newest first.
File Type Posted
Bid_Abstract.pdf PDF
Amendment_0006.pdf PDF
Amendment_0005.pdf PDF
Amendment_0005_Project_Table_of_Contents_IFB_final.pdf PDF
Amendment_0005_Sections_Specsrr.pdf PDF
Amendment_0005_CD101_-_Exhibit_-_Temporary_Fence.pdf PDF
Amendment_0005_Pershing_Submittal_Register_IFB.pdf PDF
Amendment_0003_Historical_Pictures.pdf PDF
Amendment_0003_Drawings.pdf PDF
Amendment_0003_Pershing_Field_Investigation_Report.pdf PDF
Amendment_0003_EXHIBIT_-_SITE_UTILITIES.pdf PDF
B-1_Pershing_751_Framing_plbg_roof.pdf PDF
Pershing_738_740_751_Repair Shower Rooms.pdf PDF
6833.tif TIF image
Amendment_0002_Site_Visit_Sign_In_Sheet.pdf PDF
Amendment_0002.pdf PDF
7687-5942.tif TIF image
B-7_Pershing_751_painting.pdf PDF
36993_00751_01.dwg DWG drawing
Amendment_0002_Geotechnical_Evaluation.pdf PDF
36993_00751_04.dwg DWG drawing
Pages from C-6_Pershing_751_fixtures_roof plan_windows.pdf PDF
1261.tif TIF image
7687-5941.tif TIF image
A-1_Pershing_751_Maint and Repairs.pdf PDF
LIFE SAFETY Pages from A-1_Pershing_751_Maint and Repairs 1.pdf PDF
36993_00751_02.dwg DWG drawing
C-7_Pershing_751_flooring_painting.pdf PDF
36993_00751_03.dwg DWG drawing
NO. 2.tif TIF image
A-8_Pershing_751_Roof Repl and insul.pdf PDF
7687-5947.tif TIF image
B-8_Pershing_conversion_arch_plbg_HVAC_elec.pdf PDF
C-6_Pershing_751_fixtures_roof plan_windows.pdf PDF
7687-5943.tif TIF image
A-6_Pershing_751_Maint Rep_conversion.pdf PDF
C-8_Pershing_751_floor plans_roof plan.pdf PDF
7687-5939.tif TIF image
7687-5945.tif TIF image
7687-5940.tif TIF image
B-6_Pershing_751_Floor_roof plans.pdf PDF
36993_00751_L1.dwg DWG drawing
Amendment_0001_Section_28_08_10.pdf PDF
Amendment_0001_Section_28_10_05.pdf PDF
Amendment_0001.pdf PDF
PLANS_Pages_51-100rd.pdf PDF
PLANS_Pages_251-320.pdf PDF
PLANS_Pages_1-50.pdf PDF
W912DS-16-B-0010.pdf PDF
2016_0608_Pershing_IFB_Specs_Volume_2.pdf PDF
Show all 50

Pershing Barracks Renovation/Modernization, West Point New York has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WBE certified company

LIMITED HAZARDOUS MATERIALS SURVEY

PERSHING BARRACKS

UNITED STATES MILITARY ACADEMY

WEST POINT, NEW YORK

PREPARED BY:

ATLANTIC TESTING LABORATORIES, LIMITED

251 Upper North Road Highland, New York 12528

PREPARED FOR:

ATKINS

200 Daingerfield Road

Alexandria, Virginia 22314

ATL REPORT NO. PT5236CE-01-11-14

November 7, 2014

TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Purpose

1.2 Project Team and Certifications

2.0 SCOPE OF WORK

2.1 Project Description

2.2 Inaccessible Areas

2.3 Document Review

2.4 Limitations

3.0 ASBESTOS

3.1 Methodology

3.2 Regulatory Compliance

3.3 Summary of Findings

4.0 RADON

4.1 Methodology

4.2 Summary of Findings

5.0 LEAD-CONTAINING MATERIALS

6.0 CONCLUSIONS AND RECOMMENDATIONS

6.1 Asbestos-Containing Materials

6.2 Radon

6.3 Lead-Containing Materials

APPENDICES

Licenses and Certifications ........................................................................................................ A Site Location Map ...................................................................................................................... B Sample Location Plans .............................................................................................................. C Laboratory Reports and Custody Documentation ....................................................................... D

Pershing Barracks, West Point, New York November 7, 2014 ATL Report No. PT5236CE-01-11-14

1.0 INTRODUCTION

1.1 Purpose

Atlantic Testing Laboratories, Limited (ATL) was retained by ATKINS, to perform a limited hazardous materials survey of designated areas of the Pershing Barracks, located at the United States Military Academy, West Point, New York. The limited survey was performed on July 22 and 23, 2014, and September 18 and 22, 2014. The purpose of the limited hazardous materials survey was to identify asbestos-containing materials (ACM) that are present on exposed surfaces within the subject areas, and may have a significant impact on planned renovation activities, and to test for radon within the basement areas. Lead-containing materials were also identified as an item of concern however, it is our understanding that lead sampling and analysis for the project will be provided for generated waste only, prior to transfer to a regulated disposal facility. The limited hazardous materials survey procedures and report format that follow are in general compliance with applicable local, state, and federal rules and regulations.

1.2 Project Team and Certifications

Members of the ATL project team included Cheyenne J. Dashnaw, PE, Senior Engineer; R.

Daniel Faulknham, Project Manager; James J. Reber, Project Manager; and Brian J. Babcock, Senior Technician. Certifications of ATL's field survey team members and a copy of applicable company licenses maintained by ATL are included in Appendix A.

2.0 SCOPE OF WORK

2.1 Project Description

The project site is within the Pershing Barracks at the United States Military Academy, located at 600 Thayer Road, West Point, Orange County, New York. A Site Location Map, depicting the general location of the project site, is included in Appendix B.

The intent of the limited hazardous materials survey was to conduct radon testing in designated basement areas of the subject building, and to identify suspect ACM that are located within designated areas of the subject site and may be impacted during a proposed renovation project.

Pursuant to project correspondence from ATKINS, testing for lead-based paint (LBP) was not conducted. Sampling of the waste stream during the construction phase will be conducted for subsequent Toxicity Characteristic Leaching Procedure (TCLP) lead analysis.

The limited hazardous materials survey was conducted for the subject areas, as directed by Bradley Schulz, RA, representing ATKINS. The subject areas were not occupied at the time of the sampling event.

2.2 Inaccessible Areas

The extent of inaccessible areas is dependent upon the building type, construction materials, history of renovations and repairs, and project scope. Concealed materials may exist in areas that are not readily exposed to view. Although this limited hazardous materials survey was performed to identify ACM within the subject areas, potential ACM may have escaped detection that could be encountered during future building demolition and/or renovation activities. Wall, ceiling, floor, roofing, and/or other component systems may contain concealed suspect ACM. If any suspect ACM are encountered during demolition and/or renovation activities, the activities disturbing the suspect ACM must stop and the material must be sampled and laboratory analyzed in accordance with applicable regulations.

Room numbers 03, 05, 06, 09, 16A, 17, 147A, 419, 436, and 451 were not accessible at the time of the limited hazardous materials survey. Suspect ACM within these rooms would need to be assessed by a certified Asbestos Building Inspector prior to disturbance, as necessary to verify these materials are consistent with other sampled suspect ACM or to collect requisite samples.

2.3 Document Review

Documents that were provided to ATL for review during the limited hazardous materials survey included Drawing Nos. X-101, X-102, X-103, X-104, X-105, X-201, X-202, X-203, X-204, X-301, X-302, X-303, and X-304, provided by ATKINS.

2.4 Limitations

This report has been prepared in accordance with the scope of work outlined in ATL’s contract (ATL No. PT5998-10-03-14), dated March 20, 2014, and should not be used as abatement specifications or design documents. The findings, conclusions, and recommendations presented in this report are based on the field observations made by representatives of ATL and the information provided by representatives of ATKINS.

Quantities and locations of sampled materials are approximate, and should be verified by the abatement contractor(s) prior to providing actual cost quotations and/or initiating abatement activities. Variations in reported quantities and locations for sampled materials, in addition to the discovery of suspect materials not identified in this report, is possible due to the presence of inaccessible areas, as described in Section 2.2 of this report.

The findings and opinions are relevant to the dates of our site work and should not be relied on to represent conditions at substantially later dates.

3.0 ASBESTOS

3.1 Methodology

A visual examination of the subject areas was conducted by an Asbestos Building Inspector to identify suspect ACM. Functional spaces were identified to assist while locating suspect ACM.

A functional space is defined as a spatially distinct area within a building that contains identifiable populations of building occupants. A functional space may include a room, a group of rooms, or other defined area, and several functional spaces may comprise a single homogeneous sampling area. A homogeneous sampling area is defined as an area that is uniform by color, texture, construction/application, and general appearance. Each identified functional space was visually examined to determine the locations of suspect ACM. These materials were then delineated into homogeneous sampling areas.

Samples of each accessible homogeneous area were collected and placed in clean, labeled containers. The appropriate custody documentation was completed and the suspect ACM samples were submitted to AmeriSci New York (AmeriSci), located in New York, New York.

The samples were laboratory analyzed by polarized light microscopy (PLM) and transmission electron microscopy (TEM) methodologies, as applicable. AmeriSci is a New York State Department of Health (NYSDOH) certified laboratory for PLM and TEM analysis under

Environmental Laboratory Approval Program (ELAP) No. 11480. AmeriSci is also accredited by the National Institute of Standards and Technology (NIST), under the National Voluntary Laboratory Accreditation Program (NVLAP).

3.2 Regulatory Compliance

In New York State, there are multiple regulatory agencies that have jurisdiction over ACM in buildings. Asbestos survey requirements are primarily regulated or specified by the New York State Department of Labor (NYSDOL), the New York State Department of Health (NYSDOH), the Occupational Safety and Health Administration (OSHA), and the United States Environmental Protection Agency (EPA).

The NYSDOL established Part 56 of The Official Compilation of Codes, Rules, and Regulations (cited as 12 NYCRR, Part 56) to address the proper identification, handling, removal, and disposal of ACM in buildings. Asbestos survey requirements are specified in Subpart 56-5.1 “Asbestos Survey Requirements for Building/Structure Demolition, Renovation, Remodeling and Repair.” The NYSDOL also works in conjunction with the NYSDOH to establish and maintain asbestos safety training program requirements, and enforce personnel certifications and licensing protocol for asbestos contractors.

The OSHA defines requirements for asbestos surveys and identification of ACM and presumed asbestos-containing materials (PACM) in 29 CFR 1926.1101 (k) “Communication of Hazards.”

Under this regulation, OSHA makes reference to conducting inspections according to

1926.1101 (k)(5)(ii)(B) and 1926.1101 (k)(5)(iii) or pursuant to the requirements of the Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763, Subpart E “Asbestos-Containing Materials in Schools.” The AHERA is regulated by the EPA, and applies to primary and secondary schools only; however, the procedures mandated under AHERA are generally considered the industry standards for surveys, as these are typically the most stringent.

3.3 Summary of Findings

A total of 108 homogeneous areas of suspect ACM were identified during the visual examination, from which 254 bulk samples were collected and subsequently submitted to a NYSDOH approved laboratory for analysis. Approximate sample locations are depicted on the Sample Location Plans, contained in Appendix C. A copy of laboratory reports and sample custody documentation are contained in Appendix D. Table I below provides a summary of the identified suspect ACM and associated analytical results.

Table I Summary of Suspect ACM and Analytical Results

Material General Location

Friable

Asbestos

Condition

Sample Numbers

Estimated Quantity

3, 4

White Ceiling Plaster Skim

Coat

Throughout Entire Building, Except 2 nd and rd

Floor Side Corridors Yes NAD Fair

PT5236AI01A

PT5236AI01B

PT5236AI01C

PT5236AI01D

PT5236AI01E

PT5236AI01F

PT5236AI01G

NA

Table I (continued)

Friable

Asbestos

Condition

Sample Numbers

Estimated

Gray Ceiling Plaster Base

Coat

Throughout Entire Building, Except 2 nd and rd

Floor Side Corridors Yes NAD Fair

PT5236AI02A

PT5236AI02B

PT5236AI02C

PT5236AI02D

PT5236AI02E

PT5236AI02F

PT5236AI02G

NA

White Wall Plaster Skim

Coat

Throughout Entire Building, Except 2 nd and rd

Floor Side Corridors Yes NAD Fair

PT5236AI03A

PT5236AI03B

PT5236AI03C

PT5236AI03D

PT5236AI03E

PT5236AI03F

PT5236AI03G

NA

Gray Wall Plaster Base

Coat

Throughout Entire Building, Except 2 nd and rd

Floor Side Corridors Yes NAD Fair

PT5236AI04A

PT5236AI04B

PT5236AI04C

PT5236AI04D

PT5236AI04E

PT5236AI04F

PT5236AI04G

NA

White Sink Caulk

All Cadet Rooms No NAD Good

PT5236AI05A

PT5236AI05B

NA

Brown 6-Inch Cove Base

Room Nos. 101, 102, 103, 104, 105, 108, 110, 111, 113, 114, 120, 121, 122, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 136, 139, 141, 142, 144, 146, 201, 204, 209, 210, 211, 216, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 233, 234, 235, 237, 238, 240, 242, 243, 244, 246, 247, 250, 251, 252, 253, 301, 302, 303, 304, 305, 308, 310, 311, 312, 314, 319, 320, 321, 324, 325, 326, 327, 329, 330, 331, 332, 333, 334, 336, 337, 338, 340, 341, 343, 345, 346, 348, 351, 352, 353, 401, 402, 403, 404, 405, 408, 410, 411, 412, 413, 414, 416, 419, 420, 421, 422, 423, 424, 425, 426, 429, 430, 431, 432, 433, 434, 435, 436, 437, 438, 440, 442, 445, 446, 448, and

No NAD Good

PT5236AI06A

PT5236AI06B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Yellowish-Brown Adhesive

Associated with Brown 6-Inch Cove Base

Room Nos. 101, 102, 103, 104, 105, 108, 110, 111, 113, 114, 120, 121, 122, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 136, 139, 141, 142, 144, 146, 201, 204, 209, 210, 211, 216, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 233, 234, 235, 237, 238, 240, 242, 243, 244, 246, 247, 250, 251, 252, 253, 301, 302, 303, 304, 305, 308, 310, 311, 312, 314, 319, 320, 321, 324, 325, 326, 327, 329, 330, 331, 332, 333, 334, 336, 337, 338, 340, 341, 343, 345, 346, 348, 351, 352, 353, 401, 402, 403, 404, 405, 408, 410, 411, 412, 413 414, 416, 419, 420, 421, 422, 423, 424, 425, 426, 429, 430, 431, 432, 433, 434, 435, 436, 437, 438, 440, 442, 445, 446, 448, and

No NAD Good

PT5236AI07A

PT5236AI07B

NA

Tan with Brown 12- by 12-Inch

Floor Tile

Room Nos. 101, 102, 103, 108, 105, 111, 112, 118, 120, 122, 123, 125, 127, 130, 131, 134, 142, 144, 202, 211, 212, 216, 220, 222, 223, 225, 229, 230, 231, 234, 238, 245, 248, 251, 253, 301, 305, 312, 314, 316, 320, 323, 325, 329, 330, 331, 334, 335, 337, 338, 342, 346, 348, 351, 352, 353, 401, 402, 408, 410, 411, 412, 414, 416, 419, 420, 422, 425, 429, 430, 431, 434, 435, 436, 437, 442, 445, 446, 448, and 451

No NAD Fair

PT5236AI08A

PT5236AI08B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Black Mastic Associated with Tan with Brown 12- by 12-Inch

Floor Tile

Room Nos. 101, 102, 103, 108, 105, 111, 112, 118, 120, 122, 123, 125, 127, 130, 131, 134, 142, 144, 202, 211, 212, 216, 220, 222, 223, 225, 229, 230, 231, 234, 238, 245, 248, 251, 253, 301, 305, 312, 314, 316, 320, 323, 325, 329, 330, 331, 334, 335, 337, 338, 342, 346, 348, 351, 352, 353, 401, 402, 408, 410, 411, 412, 414, 416, 419, 420, 422, 425, 429, 430, 431, 434, 435, 436, 437, 442, 445, 446, 448, and 451

No NAD Fair

PT5236AI09A

PT5236AI09B

NA

Light Gray with Gray 12- by 12- Inch Floor Tile

Room Nos. 101, 102, 104, 113, 121, 124, 126, 128, 129, 132, 133, 136, 139, 145, 208, 219, 221, 224, 226, 227, 228, 233, 237, 240, 242, 243, 246, 252, 303, 304, 305, 308, 310, 319, 321, 324, 326, 327, 332, 337, 340, 343, 350, 403, 404, 421, 423, 424, 426, 432, 433, 440, and 450

No NAD Fair

PT5236AI10A

PT5236AI10B

NA

Black Mastic Associated with Light Gray with Gray 12- by 12- Inch Floor Tile

Room Nos. 101, 102, 104, 113, 121, 124, 126, 128, 129, 132, 133, 136, 139, 145, 208, 219, 221, 224, 226, 227, 228, 233, 237, 240, 242, 243, 246, 252, 303, 304, 305, 308, 310, 319, 321, 324, 326, 327, 332, 337, 340, 343, 350, 403, 404, 421, 423, 424, 426, 432, 433, 440, and 450

No NAD Fair

PT5236AI11A

PT5236AI11B

NA

Gray/Tan/Beige Terrazzo Floor and Cove Base

Throughout Building Except for Basement and Stair Towers No NAD Good

PT5236AI12A

PT5236AI12B

NA

Salmon Speckled 12- by

12-Inch Floor Tile

Room Nos. 102, 338, and 442

No NAD Fair

PT5236AI13A

PT5236AI13B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Yellow/Brown Mastic

Associated with Salmon

Speckled 12- by 12-Inch Floor

Tile

Room Nos. 102, 338, and 442

No NAD Fair

PT5236AI14A

PT5236AI14B

NA

Brown Blended 12- by 12- Inch

Floor Tile

Room Nos. 102, 105, 114, 118, 123, 126, 127, 128, 131, 220, 230, 231, 238, 242, 245, 252, 304, 305, 308, 313, 319, 320, 327, 330, 337, 340, 353, 355, 404, 405, 412, 413, 414, 434, 437, 448, and 451; Stair Tower No. 5

No NAD Fair

PT5236AI15A

PT5236AI15B

NA

Yellow/Brown Mastic

Associated with Brown Blended 12- by 12- Inch

Floor Tile

Room Nos. 102, 105, 114, 118, 123, 126, 127, 128, 131, 220, 230, 231, 238, 242, 245, 252, 304, 305, 308, 313, 319, 320, 327, 330, 337, 340, 353, 355, 404, 405, 412, 413, 414, 434, 437, 448, and 451; Stair Tower No. 5

No NAD Fair

PT5236AI16A

PT5236AI16B

NA

Beige with White and Gray 12- by

12-Inch Floor Tile

Room Nos. 104, 142, 245, 252, 253, 312, 325, 335, 340, 350, and 433

No NAD Fair

PT5236AI17A

PT5236AI17B

NA

Black Mastic Associated with Beige with White and Gray 12- by

12-Inch Floor Tile

Room Nos. 104, 142, 245, 252, 253, 312, 325, 335, 340, 350, and 433

No NAD Fair

PT5236AI18A

PT5236AI18B

NA

Light Blue with Brown 12- by 12-Inch Floor

Tile

Room Nos. 104, 124, 344B, 344C, 406, 411, 412, 414, 430, and 433

No NAD Fair

PT5236AI19A

PT5236AI19B

NA

Yellow/Black Mastic

Associated with Light Blue with Brown 12- by 12-Inch Floor

Tile

Room Nos. 104, 124, 344B, 344C, 406, 411, 412, 414, 430, and 433

No NAD Fair

PT5236AI20A

PT5236AI20B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Gray Blended 12- by 12-Inch

Floor Tile

Room Nos. 110, 118, 123, 125, 131, 138, 211, 214, 229, 238, 242, 243, 244, 250, 251, 253, 301, 308, 323, 330, 331, 333, 340, 344, 357, 401, 402, 414, 421, 422, 423, and

No NAD Fair

PT5236AI21A

PT5236AI21B

NA

Yellow/Black Mastic

Associated with Gray Blended 12- by 12-Inch

Floor Tile

Room Nos. 110, 118, 123, 125, 131, 138, 211, 214, 229, 238, 242, 243, 244, 250, 251, 253, 301, 308, 323, 330, 331, 333, 340, 344, 357, 401, 402, 414, 421, 422, 423, and

No NAD Fair

PT5236AI22A

PT5236AI22B

NA

Gray with Brown 12- by 12-Inch

Floor Tile

Room Nos. 114, 119, 142, 215, 231, 234, 404 and 431 No NAD Fair

PT5236AI23A

PT5236AI23B

NA

Yellow/Black Mastic

Associated with Gray with Brown 12- by 12-Inch

Floor Tile

Room Nos. 114, 119, 142, 215, 231, 234, 404 and 431 No NAD Fair

PT5236AI24A

PT5236AI24B

NA

Tan with White Terrazzo Floor, Cove Base, and

Stair Tread

All Four Levels of Stair Towers

No NAD Fair

PT5236AI25A

PT5236AI25B

NA

Tan with Brown and White 12- by

12-Inch Floor Tile

Room Nos. 120, 146, 202, 203, 204, 214, 250, 342, 344C, 445, and 452A

No NAD Fair

PT5236AI26A

PT5236AI26B

NA

Black Mastic Associated with Tan with Brown and White 12- by 12-Inch Floor

Tile

Room Nos. 120, 146, 202, 203, 204, 214, 250, 342, 344C, 445, and 452A

No NAD Fair

PT5236AI27A

PT5236AI27B

NA

Gray Exterior Ceiling Plaster

Room No. 127A and Vestibule No. 4B

Yes NAD Fair

PT5236AI28A

PT5236AI28B

PT5236AI28C

NA

White Floor Leveler

Room No. 127 at Door Threshold

Yes NAD Fair

PT5236AI29A

PT5236AI29B

NA

Tan with Brown and White 12- by

12-Inch Floor Tile

Room Nos. 130 and 342 No NAD Fair

PT5236AI30A

PT5236AI30B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Yellow/Black

Associated with Tan with Brown and White 12- by 12-Inch Floor

Tile

Room Nos. 130 and 342 No NAD Fair

PT5236AI31A

PT5236AI31B

NA

Beige with Brown/White/Gr ay 12- by 12- Inch Floor Tile

Room Nos. 132, 303, 325, and 440

No NAD Fair

PT5236AI32A

PT5236AI32B

NA

Black Mastic Associated with

Beige with Brown/White/Gr ay 12- by 12- Inch Floor Tile

Room Nos. 132, 303, 325, and 440

No NAD Fair

PT5236AI33A

PT5236AI33B

NA

White Grout Associated with

4- by 4-Inch Ceramic Wall

Tile

Bathrooms and Shower Rooms

Yes NAD Fair

PT5236AI34A

PT5236AI34B

NA

Gray Mortar Bed Associated with

4- by 4-Inch Ceramic Wall

Tile

Bathrooms and Shower Rooms

Yes NAD Fair

PT5236AI35A

PT5236AI35B

NA

Gray Grout Associated with

Gray Mosaic Ceramic Floor

Tile

Room Nos. 07, 11B, 11C, 15, 15A, 19, 107, 107A, 117, 135, 143, 143A, 207, 207A, 217, 239, 247, 247A, 307, 307A, 307B, 307C, 318, 339, 347, 347A, 347B, 347C, 347D, 407, 407A, 417, 439, 447, 447A

Yes NAD Fair

PT5236AI36A

PT5236AI36B

NA

Gray Grout Associated with

1- by 1-Inch Ceramic Floor

Tile

Shower Rooms Yes NAD Fair

PT5236AI37A

PT5236AI37B

NA

Gray Grout Associated with Mosaic Ceramic

Floor Tile

Stair No.1 Yes NAD Fair

PT5236AI38A

PT5236AI38B

NA

Gray Grout Associated with

4- by 8-Inch Glazed Ceramic

Wall Tile

Room Nos. 08, 11, 14, 16, and 147

Yes NAD Fair

PT5236AI40A

PT5236AI40B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Black 6-Inch Cove Base

Room Nos. 203, 204, 205, 208, 210, 211, 212, and 214 No NAD Fair

PT5236AI41A

PT5236AI41B

NA

Tan/Yellow Adhesive

Associated with Black 6-Inch Cove Base

Room Nos. 203, 204, 205, 208, 210, 211, 212, and 214 No NAD Fair

PT5236AI42A

PT5236AI42B

NA

White with Gray and Blue 12- by 12-Inch Floor

Tile

Room Nos. 205 and 210 No NAD Fair

PT5236AI43A

PT5236AI43B

NA

Amber/Yellow Mastic

Associated with White with Gray and Blue 12- by 12-Inch Floor

Tile

Room Nos. 205 and 210 No NAD Fair

PT5236AI44A

PT5236AI44B

NA

White Bathroom Fixture Caulk

Bathrooms No NAD Good

PT5236AI45A

PT5236AI45B

NA

Blue and White Blended 12- by 12-Inch Floor

Tile

Room Nos. 212 and 401 No NAD Fair

PT5236AI46A

PT5236AI46B

NA

Black/Amber Mastic

Associated with Blue and White Blended 12- by 12-Inch Floor

Tile

Room Nos. 212 and 401 No NAD Fair

PT5236AI47A

PT5236AI47B

NA

Light Blue with White Blended 12- by 12-Inch

Floor Tile

Room Nos. 212 and 253 No NAD Fair

PT5236AI48A

PT5236AI48B

NA

Black/Amber Mastic

Associated with Light Blue with White Blended 12- by 12-Inch

Floor Tile

Room Nos. 212 and 253 No NAD Fair

PT5236AI49A

PT5236AI49B

NA

Red Firestop Room Nos. 4A, 9A, 11, 115, 137, 215, 241, 315, 341, 415, and 441

No NAD Good

PT5236AI50A

PT5236AI50B

NA

Light Gray with Multicolor 12- by

12-Inch Floor Tile

Room Nos. 220, 235, 350, 351, and 437

No NAD Fair

PT5236AI51A

PT5236AI51B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Black/Amber

Associated with Light Gray with

Multicolor 12- by 12-Inch Floor

Tile

Room Nos. 220, 235, 350, 351, and 437

No NAD Fair

PT5236AI52A

PT5236AI52B

NA

Tan Blended 12-by 12-Inch Floor

Tile

Room Nos. 252, 319, and 444

No NAD Fair

PT5236AI53A

PT5236AI53B

NA

Black Mastic Associated with Tan Blended 12-by 12-Inch Floor

Tile

Room Nos. 252, 319, and 444

No NAD Fair

PT5236AI54A

PT5236AI54B

NA

Dark Gray with White 12- by 12- Inch Floor Tile

Room No. 253 and Elevator

No NAD Fair

PT5236AI55A

PT5236AI55B

NA

Amber/Black Mastic

Associated with Dark Gray with

White 12- by 12- Inch Floor Tile

Room No. 253 and Elevator

No NAD Fair

PT5236AI56A

PT5236AI56B

NA

White with Dark and Light Gray 12- by 12-Inch

Floor Tile

Room Nos. 342 and 450 No NAD Fair

PT5236AI57A

PT5236AI57B

NA

Amber/Black Mastic

Associated with White with Dark and Light Gray 12- by 12-Inch

Floor Tile

Room Nos. 342 and 450 No NAD Fair

PT5236AI58A

PT5236AI58B

NA

Gray with Dark Gray and White 12- by 12-Inch

Floor Tile

Room No. 340 No NAD Fair

PT5236AI59A

PT5236AI59B

NA

Black Mastic Associated with Gray with Dark Gray and White 12- by 12-Inch

Floor Tile

Room No. 340 No NAD Fair

PT5236AI60A

PT5236AI60B

NA

Moth with White Blended 12- by 12-Inch Floor

Tile

Room No. 351 No NAD Fair

PT5236AI61A

PT5236AI61B

Friable

Asbestos

Condition

Sample Numbers

Estimated

Amber/Black

Associated with Moth with White Blended 12- by 12-Inch Floor

Tile

Room No. 351 No NAD Fair

PT5236AI62A

PT5236AI62B

NA

Gray Gypsum Board

Room Nos. 429 and 501; 2 nd and 3 rd Floor

Side Corridors Yes NAD Good

PT5236AI63A

PT5236AI63B

NA

White Joint Compound

Room Nos. 429 and 501; 2 nd and 3 rd Floor

Side Corridors Yes NAD Good

PT5236AI64A

PT5236AI64B

NA

Black Vapor Barrier

Room No. 501 (Under Carpet)

No NAD Fair

PT5236AI65A

PT5236AI65B

NA

Brown Cement- Like Floor Fill

Material

Various Areas Throughout Building

Yes NAD Poor

PT5236AI66A

PT5236AI66B

NA

Tan 6-Inch Cove Base

Room Nos. 452 and 452A

No NAD Good

PT5236AI67A

PT5236AI67B

NA

Brown/Tan/Yello w Adhesive

Associated with Tan 6-Inch Cove

Base

Room Nos. 452 and 452A

No NAD Good

PT5236AI68A

PT5236AI68B

NA

Brown Residual Chalkboard Adhesive

Room Nos. 452 and 452A

No NAD Fair

PT5236AI69A

PT5236AI69B

NA

Black Residual Chalkboard Adhesive

Room Nos. 452 and 452A

No 4.5 Fair

PT5236AI70A

PT5236AI70B

Square

Feet

Green Wardrobe Flooring

All Cadet Rooms No NAD Good

PT5236AI71A

PT5236AI71B

NA

White Fiberglass Thermal System Insulation (TSI)

Jacket

Throughout Structure No NAD Fair

PT5236AI72A

PT5236AI72B

PT5236AI72C

NA

White TSI Pipe End Sealant

Throughout Structure No NAD Fair

PT5236AI73A

PT5236AI73B

PT5236AI73C

NA

White TSI Tank Lag Cloth

Room No. 02A No NAD Fair

PT5236AI74A

PT5236AI74B

PT5236AI74C

NA

Gray Plaster Wall Patch

Room Nos. 07, 08, and 08A

Yes NAD Fair

PT5236AI75A

PT5236AI75B

PT5236AI75C

NA

White Vibration Cloth

Room No. 07 Yes NAD Fair

PT5236AI77A

PT5236AI77B

NA

White Duct Jacket

Room No. 07 Yes NAD Fair

PT5236AI78A

PT5236AI78B

PT5236AI78C

Friable

Asbestos

Condition

Sample Numbers

Estimated

Gray Duct Sealant

Above Ceiling in 4 th

Floor Corridor No NAD

PT5236AI79A

PT5236AI79B

NA

Brown with Tan and Black Small

Aggregate Terrazzo Flooring

Room Nos. 08, 08A, 11, 11A, and 14

No NAD Fair

PT5236AI80A

PT5236AI80B

NA

Black Residual Mastic

Room No. 08A No NAD Fair

PT5236AI81A

PT5236AI81B

NA

White Firestop Room No. 08A Yes NAD Good

PT5236AI82A

PT5236AI82B

NA

White Window Caulk

Room No. 11 No NAD Fair

PT5236AI83A

PT5236AI83B

NA

Black Tar on Pipe

Room Nos. 11, 12A, 14, 23A, 24, 24A, and 25A

No NAD Fair

PT5236AI84A

PT5236AI84B

NA

Black Floor Patch

Room Nos. 20, 20A, 22, 23, 24, 24A, and 25

No NAD Fair

PT5236AI85A

PT5236AI85B

NA

Beige Pipe Caulk

Room No. 25A No NAD Fair

PT5236AI86A

PT5236AI86B

NA

Black Vapor Barrier

Throughout Structure No NAD Fair

PT5236AI87A

PT5236AI87B

NA

Gray Flashing Caulk

Associated with Gray Metal Flashing

Roof Flashing No NAD Fair

PT5236AI88A

PT5236AI88B

NA

Silver Flashing Paint

Roof Flashing No Trace Fair

PT5236AI89A

PT5236AI89B

NA

White Flashing Caulk

Associated with Gray Metal Flashing

Roof Flashing No Trace Fair

PT5236AI90A

PT5236AI90B

NA

Beige Perimeter Caulk

Vents and Roof Penetrations

No NAD Fair

PT5236AI91A

PT5236AI91B

NA

White Caulk Associated with

Green Metal Roofing

Roof Flashing No Trace Fair

PT5236AI92A

PT5236AI92B

NA

Dark Gray Window Caulk

Window to Room No.

501 and Stair Tower

Windows No NAD Fair

PT5236AI93A

PT5236AI93B

NA

Gray/Black Asphalt Roof Membrane

Roof No NAD Fair

PT5236AI94A

PT5236AI94B

NA

Black Felt Paper Roof No NAD Fair

PT5236AI95A

PT5236AI95B

NA

Brown Fiberboard

Roof Yes NAD Fair

PT5236AI96A

PT5236AI96B

Friable

Asbestos

Condition

Sample Numbers

Estimated

White/Gray Flashing

Membrane Roof No NAD Fair

PT5236AI97A

PT5236AI97B

NA

White Adhesive Associated with

White/Gray Flashing

Membrane

Roof No NAD Fair

PT5236AI98A

PT5236AI98B

NA

Black/Gray Flashing Patch

Membrane Roof No NAD Fair

PT5236AI99A

PT5236AI99B

NA

Dark Gray Window Caulk

Basement and 1 st Floor

Windows No NAD Fair

PT5236AI100A

PT5236AI100B

NA

Gray Door Caulk

Room No. 147; Corridor No. 1A; Vestibule No.

04B; Stairwell 1, 2, 3, and 4

No NAD Fair

PT5236AI101A

PT5236AI101B

NA

Gray Exterior Window Caulk nd

, 3 rd

, and 4 th

Floor Windows

No NAD Fair

PT5236AI102A

PT5236AI102B

NA

Light Gray Expansion Caulk

Corridor No. 01A to Vestibule No. 4B

(Exterior) No NAD Fair

PT5236AI103A

PT5236AI103B

NA

Tan Floor Tile st and 2 nd Floor Cadet

Rooms Below Plywood

No 6.6 Fair

PT5236AI104A

PT5236AI104B

20,486 Square

Feet

Black Floor Tile Mastic/Vapor

Barrier st and 2 nd Floor Cadet

Rooms Below Plywood

No Trace Fair

PT5236AI105A

PT5236AI105B

NA

Black/Brown Vapor Barrier rd and 4 th Floor Cadet

Rooms No NAD Fair

PT5236AI106A

PT5236AI106B

NA

White Ceiling Plaster Skim

Coat at Upper Ceiling

Above Plaster Ceiling on nd , 3 rd , and 4 th Floors

Yes NAD Poor

PT5236AI107A

PT5236AI107B

PT5236AI107C

PT5236AI107D

PT5236AI107E

PT5236AI107F

PT5236AI107G

NA

Gray Ceiling Plaster Base Coat at Upper

Ceiling

Above Plaster Ceiling on nd , 3 rd , and 4 th Floors

Yes NAD Poor

PT5236AI108A

PT5236AI108B

PT5236AI108C

PT5236AI108D

PT5236AI108E

PT5236AI108F

PT5236AI108G

Friable

Asbestos

Condition

Sample Numbers

Estimated

Gray TSI Mudded Fitting

Wet Wall Associated with Bathrooms

6 Yes 50.0 Fair

PT5236AI109A

PT5236AI109B

PT5236AI109C

20 Square Feet

Brown Layer Paper TSI

Wet Wall Associated with Bathrooms

6 Yes 12.1 Fair

PT5236AI110A

PT5236AI110B

PT5236AI110C

Square

Feet

Notes:

Sample Location Plans are enclosed in Appendix C.

NAD = No Asbestos Detected

Quantities and locations are approximate and must be verified by asbestos abatement contractors prior to providing actual cost quotations and/or initiating abatement activities.

NA = Not Applicable

Tan Floor Tile and Black Floor Tile Mastic/Vapor Barrier were observed below a layer of plywood flooring in Room Nos. 105 and 220 at the time of the limited hazardous materials survey sampling event. These materials may exist in additional cadet rooms on the 1 st and 2 nd floors.

Material was accessible and/or visible in the 2 nd , 3 rd , and 4 th floor bathrooms. Material was not accessible in the wet walls on the st Floor and Basement Level and may exist in additional areas on these levels.

The EPA, NYSDOL, and other regulatory agencies define ACM as any material containing greater than 1% of asbestos. Materials listed in bold font in Table I above were determined to be ACM.

Materials containing trace asbestos (i.e., less than 1%) are not considered ACM; however, the OSHA recognizes materials that contain trace amounts of asbestos, and requires these materials be handled in accordance with their standard interpretation letter titled “Requirements for demolition operations involving material containing <1% asbestos “, dated August 13, 1999.

As shown in Table I above, 4 materials were determined to contain trace amounts of asbestos.

4.0 RADON

4.1 Methodology

A visual examination of the subject areas was conducted by an Environmental Scientist to identify areas with a higher potential for radon migration, if present, based on location relative to subsurface soil/rock and conditions of building materials for areas in contact with subsurface soil/rock. Since the conditions of building materials were observed to be relatively consistent, six sample locations were randomly selected from rooms in the basement area that are in direct contact with subsurface soil/rock. The basement area is the lowest occupied space of the subject building. Short duration (2-4 days) radon test kits were used to detect concentrations of radon in picocuries per liter (pCi/L) of air.

Test kits were placed and remained on-site for duration of 4 days. After the 4-day period, the samples were collected and submitted to Airchek, Inc., located in Mills River, North Carolina.

The samples were laboratory analyzed for radon, in accordance with applicable methods.

Airchek, Inc., is a NYSDOH approved laboratory under Environmental Laboratory Approval Program (ELAP) No. 11441.

4.2 Summary of Findings

The six radon samples, placed in the basement area of the subject building, were collected and subsequently submitted to a NYSDOH ELAP approved laboratory for analysis. Approximate sample locations are depicted on the Sample Location Plans, contained in Appendix C. A copy of laboratory reports and associated sample custody documentation are contained in Appendix D. Table II below provides a summary of the radon sample location and analytical results.

Table II Summary of Suspect LBP and Analytical Results

General Location Sample

Numbers Laboratory Results

(pCi/L)

Steam Room 01 PT5236RB01 <0.3

Trunk Room 010 PT5236RB02 1.2 +/- 0.2

Electrical Service Room 013 PT5236RB03 1.6 +/- 0.2

Mountaineering 017 PT5236RB04 0.7 +/- 0.1

Trunk Room 025 PT5236RB06 <0.3

Trunk Room 023a PT5236RB05 <0.3

The United States Environmental Protection Agency (EPA) has identified an action level for the concentration of radon in homes and commercial buildings at 4.0 pCi/L. The EPA recommends that corrective action be taken to reduce radon levels below 4.0 pCi/L. The EPA also suggests that corrective action be taken at radon levels between 2.0 pCi/L and 4.0 pCi/L. Typical outdoor background exposure to radon is 0.4 pCi/L.

None of the samples collected were determined to be at or above action level, as identified by the EPA. Radon was detected for 3 of the 6 collected samples, at concentrations ranging between 0.7 and 1.6 pCi/L.

5.0 LEAD-CONTAINING MATERIALS

Pursuant to project correspondence between ATL and ATKINS, an assessment for lead-containing materials was not conducted during the limited hazardous materials survey. It is our understanding that sampling and analysis for lead in the waste stream to be generated during renovations will be performed at the start of the construction phase. Representative samples of the waste stream will be collected and submitted for Toxicity Characteristic Leaching Procedure (TCLP) lead analysis. Based on the selected on the selected methods for management of potential lead-containing materials, any suspect lead-containing materials shall be assumed to contain lead and appropriately managed during the renovation work activities.

6.0 CONCLUSIONS AND RECOMMENDATIONS

The following conclusions and recommendations are prepared from ATL’s understanding that the subject building may be subject to renovation projects. Should the management of the building areas change, it is recommended that the findings be revisited to reflect appropriate operations and management practices for ACM and radon within buildings.

6.1 Asbestos-Containing Materials

1. Concealed regulated ACM may exist at the site that could be encountered during future building renovation activities. Wall, ceiling, floor, roofing, and/or other component systems may contain concealed suspect ACM. If any suspect ACM is encountered during demolition and/or renovation activities, the activities disturbing the suspect ACM must stop and the material must be sampled and laboratory analyzed in accordance with applicable regulations.

2. The materials listed in bold in Table I of Section 3.3 were determined to be ACM. The referenced table also shows materials that contain trace concentrations of asbestos and are regulated under OSHA.

3. Subpart 56-5(h) of 12 NYCRR Part 56 requires that no demolition, renovation, remodeling, or repair work be commenced by any owner or the owner’s agent prior to the completion of asbestos abatement. Asbestos abatement must be performed by an asbestos abatement contractor that maintains a current asbestos handling license, and employs NYSDOL certified asbestos handlers and supervisors. It is recommended that a 12 NYCRR 56 certified Project Monitor oversee abatement activities.

4. Subpart 56-5(g) of 12 NYCRR Part 56 specifies requirements for transmittal of asbestos survey information by the owner or owner’s agent. One copy of the asbestos survey report shall be sent to the local government entity charged with issuing a permit for such demolition, renovation, remodeling, or repair work under applicable State or local laws. If controlled demolition or pre-demolition activities will be performed, one copy of the asbestos survey report shall be submitted to the appropriate Asbestos Control Bureau district office.

One copy of the asbestos survey report must be kept on the construction site throughout the duration of the asbestos project and any associated demolition, renovation, remodeling, or repair project.

6.2 Radon

1. None of the 6 samples collected were determined to be at or above action levels identified by EPA. There was radon detected in 3 of the 6 samples at concentrations ranging between

0.7 and 1.6 pCi/L. Based on the detected presence of radon, it is recommended that the building be periodically tested for radon levels, especially as building materials adjacent to subsurface soil/rock start to crack or deteriorate and after any building renovations that may increase the potential for radon migration.

2. Should corrective action be chosen to reduce the detectable concentration of radon, remediation should be managed in accordance with applicable EPA guidelines and completed by experienced and qualified contractors.

6.3 Lead-Containing Materials

1. As indicated in Section 5.0, representative samples of the waste stream to be generated during renovations will be performed at the start of the construction phase. Based on the selected methods for management of potential lead-containing materials, any suspect lead-containing materials shall be assumed to contain lead and appropriately managed during the renovation work activities.

A

APPENDIX A

LICENSES AND CERTIFICATIONS

other on file

Asbestos Certificate Code Classifications

The following letter codes shown on the enclosed asbestos certificates represent the corresponding asbestos classifications:

A - Asbestos Handler F - Operations & Maintenance B - Allied Trades G - Asbestos Supervisor C - Air Sampling Technician H - Asbestos Project Monitor D - Building Inspector I - Asbestos Project Designer E - Management Planner

Ny(AP- ^."u"W""\..ffi;National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

AmeriSci New York DBA: AmeriSci New York

117 E. 30th Street NewYork,NY 10016

Mr. Paul Mucha Phone: 212-679-8600 Fax: 212-679-27 11

E-Mail : pmucha@amerisci.com URL: http://rwr,v.amerisci.com

BULK ASBESTOS FIBER ANALYSIS (PLM) NVLAPLABCODE 200546-0

Designation / Description

EPA 600/M4-82-020: Interim Method for the Determination of Asbestos in Bulk Insulation Samples

EPA 600,R-93/116: Method for the Determination of Asbestos in Bulk Building Materials

NVI.IIP Code

18/A01

18/A03

Effective dates

Page 1of 1

201 4-07 -01 through 20 I 5-06-30 tu fl ,tl,t-LQ For the National lnstitute of Standards and Technology

NVLAP-o1S (REV. 2005.05-19)

UI

v.

(J o-l z o.)

o e e o

(D a q

a) ltt

(g oa q)

,P

?s

SI

FE

N b fl FE' Y F a

^t o sa' u E { 8 , E A O N

E { S tI ; . E e r g E E G : O E 6 i E > 6 e * 5 - ) E ; ' d o ^ Q H { E t s s # i : e F s SE 5 E * J E F sR F > - E * X i E s. : i > z E H f , . s x . .

e a r u S t = b t s 5 z E S € I - R I g : ' 5 F E $ k [ t + 3 ? i ! { F i s a ; i z F e 3 : B E I E S i E H E * = 2 -i e E V T i E' ) i I . \< c )

- h -c e * t i* -i . F x 8x x ;

E i r 8 E Q" i F e

- * E

- . p l'-sd^- ""'z iFffi} z t'- 6 tn* r uono ut g) o a q) h

F-

N

ItO o oql 1() o N F

O

IIJ

o I o c o t -

{r,(E .E !t o l-o o lts o o

{d(u o t -tF.E L oo

@ - l t=l!

E:J I z t o)o ,cl 6 o - c t r o E P 9 o\., c tF Cto o t s E o c t t r E

F So-u, O u -o o o o o = g E A o

- c o -t ( s c c : . 9 z

B

APPENDIX B

SITE LOCATION MAP

Site Location Map Drawn by:

JJR

Scale:

Not to scale

Project No.:

PT5236

Date:

November 2014

West Point Military Academy Pershing Barracks 600 Thayer Road

West Point, Orange County, New York

ATLANTIC TESTING LABORATORIES, Limited Albany, NY Binghamton, NY Canton, NY Elmira, NY Plattsburgh, NY

Poughkeepsie, NY Syracuse, NY Rochester, NY Utica, NY Watertown, NY

Project Site

C

APPENDIX C

SAMPLE LOCATION PLANS

ATL Report No. PT5136CE-01-11-14

D

APPENDIX D

LABORATORY REPORTS AND CUSTODY DOCUMENTATION

U@'fFwM.u,/ AuenLScr

AmeriSci New York

1 17 EAST 3OTH ST.

NEW YORK, NY 10016

rEL: (212) 679-8600 , FM: (212) 679-3114

PLM Bulk Asbestos Report Atlantic Testing Laboratories, Limited Date Received 071291L4 AmeriSci Job # 2L4075800

Attn: James Reber Date Examined 07131114 P.O. # 5236-01 to 5236-18

P.O. Box 29 ELAP # 11480 Page 1 of 41

RE: PT5236; Pershing Barracks; West Point, NY

Canton, NY 13617

Glient No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236AI01A 214075800-01 /Vo NAD

01 Location: 43SAlWhiteSkim CoatOf PlasterCeiling (byNYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|01B 214075800-02 /Vo NAD

01 Location: Room 447 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|01C 214075800-03 No NAD

01 Location: Stair # 1 @ 3rd Level / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AI01D 214075800-04 IVo NAD

01 Location: Room 349 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|01E 214075800-05 No NAD

01 Location: Room247 /WhiteSkimCoatOf PlasterCeiling (byNYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 100 %

See Reporting notes on last page

AmeriSci Job #: 214075800

Client Name: Atlantic Testing Laboratories, Limited

PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236AI01F 214075800-06 IVo NAD

01 Location: Room 11 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|01G 214075800-07 No NAD

01 Location: Stair # 4 @ Basement / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O2A 214075800-08 No NAD

OZ Location: 438A tGray Base Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|02B 214075800-09 /Vo NAD

02 Location: Room 447 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 1 98.1 ) by Tara L. Fisher on 07 131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AI02C 214075800-10 A/o NAD

02 Location: Stair#1@3rdLevel/GrayBaseCoatOf PlasterCeiling (byNYSELAP198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AIO2D 214075800-11 /Vo NAD

02 Location: Room 349 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 1 98.1 ) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

PLM Bulk Asbestos RePort PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236A|O2E 214075800-12 No NAD

02 Location: Room 247 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) bY Tara L. Fisher on 07 131114

Analyst Description: Grey, Homogeneous, Non-Fibrous' Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AIO2F 214075800-13 /Vo NAD

02 Location: Room 1 1 t Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) by Tara L. Fisher on 07131114

Anatyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|02G 214075800-14 No NAD

02 Location: Stair # 4 @ Basement Level / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AIO3A 214075800-15 /Vo NAD

03 Location: Room 19 / Wht. Skim coat @ walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AI03B 214075800-16 /Vo NAD

03 Location: Room 131 / Wht. Skim coat @ walls (by NYS ELAP 198.1) bY Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O3C 214075800-17 /Vo NAD

03 Location: Room '134A / WhL Skim Coat @ Walls (by NYS ELAP 198'1) bY Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

See Reporting notes on last Page

PLM Bulk Asbestos RePort PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos

PT52364l03D

214075800-18 Location: Room 296 / Wht. Skim Coat @ Walls

No NAD (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous' Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|03E 214075800-19 A/o NAD

03 Location: Room301 /Wht.Skimcoat@walls (byNYSELAP198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O3F 214075800-20 A/o NAD

03 Location: Room306/Wht.skimcoat@walls (byNYSELAP198.1) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236AIO3G 214075800-21 /Vo NAD

03 Location: Room 420 / Wht. Skim coat @ walls (by NYS ELAP 198.1) by Tara L. Fisher on 07 131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O4A 214075800-22 IVo NAD

04 Location: Room 19 / Gray Base Coat @ Walls (by NYS ELAP 198.1) bY Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O4B 214075800-23 A/o NAD

04 Location: Room 131 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236A|04C 214075800-24 IVo NAD

04 Location: Room 134A / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O4D 214075800-25 A/o NAD

04 Location: Room 296 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|04E 214075800-26 /Vo NAD

04 Location: Room 301 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|O4F 214075800-27 IVo NAD

04 Location: Room 306 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 7o

PT5236A|04G 214075800-28 No NAD

04 Location: Room 420 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114

Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Typesl Other Material: Non-fibrous 100 %

PT5236A|O5A 214075800-29 Alo NAD

05 Location: Room 124 / Wht. Sink Caulk (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material

Asbestos Types:

Other Material : Non-fibrous 2.2 o/o

AmeriSci Job #: 2'1407 5800

PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos PT5236A|05B 214075800-30 No NAD 05 Location: Room 227 / wht. Sink Caulk (by NyS ELAP i 98.6) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 0.4 %

PT5236A|06A 214075800-31 No NAD 06 Location: Room 230 / 6" Brown Cove Base (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Brown, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 35.4 %

PT5236A|06B 214075800-32 No NAD 06 Location: Room 114 / 6" Brown Cove Base (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Brown, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 34 %

PT5236A|07A 214075800-33 AIo NAD 07 Location: Room 230 / Yellowish Brown Adhesive (by NYS ELAP 193.6) by Tara L. Fisher on 07131114

Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 21 .6 o/o

PT5236A|07B 214075800-34 /Vo NAD 07 Location: Room 114 / Yellowish Brown Adhesive (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 10.2 o/o

PT5236A|08A 214075800-35 IVo NAD 08 Location: Room 142 lfanWlBrown 12x12 FloorTile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 9.3 %

PageT of 41

PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY

Client No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236A|08B 214075800-36 /Vo NAD

08 Location: Room 334 lTantNl Brown 12x12 Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 13.2 o/o

PT5236AI09A 214075800-37 No NAD 09 Location: Room 142 / Black Mastic Assoc. W/ 08 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 12.1 o/o

PT5236A|09B 214075800-38 No NAD 09 Location: Room 334 / Black Mastic Assoc. W/ 08 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 1.2 o/o

PT5236A|10A 214075800-39 No NAD

10 Location: Room 130 / Lt. Gray W/ Gray Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 7 .1 o/o

PT5236A|10B 214075800-40 No NAD 10 Location: Room 332 / Lt. Gray W/ Gray Floor Tile (by NYS ELAP 198.6) byTara L. Fisher on 07131114

Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 0.8 %

PT5236A|11A 214075800-41 No NAD 11 Location: Room 130 / Black Mastic Assoc. W/ 10 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 3.6 %

PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY

CIient No. / HGA Lab No. Asbestos Present Total % Asbestos

PT5236Al1'tB 214075800-42 No NAD

11 Location: Room # 332 / Black Mastic Assoc. W/ 10 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 7.6 %

PT5236A|12A 214075800-43 No NAD

12 Location: 218A I Gray / Tan / Beige Terrazzo Floor (by NYS ELAP 198.1 ) by Tara L. Fisher on 07131114

Analyst Description: Brown/Grey, Homogeneous, Non-Fibrous, Cementitious, Bulk Material

Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|12B 214075800-44 IVo NAD

12 Location: 101A I Gray / Tan / Beige f enazzo Floor & Cove Base (by NYS ELAP 198.1 ) by Tara L. Fisher on 07131114

Analyst Description: Grey/Brown, Homogeneous, Non-Fibrous, Cementitious, Bulk Material Asbestos Types:

Other Material: Non-fibrous 100 %

PT5236A|13A 214075800-45 /Vo NAD

13 Location: Room 102 / Salmon Speckled l2xl2FloorTile (by NYS ELAP 198.6) by Tara L. Fisher on 07 131114

Analyst Description: Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 0.4 %

PT5236AI13B 214075800-46 No NAD

1 3 Location: Room 442 / Salmon Speckled 12x12 Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst Description: Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:

Other Material: Non-fibrous 1.1 %

PT5236A|14A 214075800-47 /Vo NAD

14 Location: Room 102 / Yellow / Brown Mastic W/ 13 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114

Analyst…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .