LIMITED HAZARDOUS MATERIALS SURVEY
PERSHING BARRACKS
UNITED STATES MILITARY ACADEMY
WEST POINT, NEW YORK
PREPARED BY:
ATLANTIC TESTING LABORATORIES, LIMITED
251 Upper North Road Highland, New York 12528
PREPARED FOR:
ATKINS
200 Daingerfield Road
Alexandria, Virginia 22314
ATL REPORT NO. PT5236CE-01-11-14
November 7, 2014
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Purpose
1.2 Project Team and Certifications
2.0 SCOPE OF WORK
2.1 Project Description
2.2 Inaccessible Areas
2.3 Document Review
2.4 Limitations
3.0 ASBESTOS
3.1 Methodology
3.2 Regulatory Compliance
3.3 Summary of Findings
4.0 RADON
4.1 Methodology
4.2 Summary of Findings
5.0 LEAD-CONTAINING MATERIALS
6.0 CONCLUSIONS AND RECOMMENDATIONS
6.1 Asbestos-Containing Materials
6.2 Radon
6.3 Lead-Containing Materials
APPENDICES
Licenses and Certifications ........................................................................................................ A Site Location Map ...................................................................................................................... B Sample Location Plans .............................................................................................................. C Laboratory Reports and Custody Documentation ....................................................................... D
Pershing Barracks, West Point, New York November 7, 2014 ATL Report No. PT5236CE-01-11-14
1.0 INTRODUCTION
1.1 Purpose
Atlantic Testing Laboratories, Limited (ATL) was retained by ATKINS, to perform a limited hazardous materials survey of designated areas of the Pershing Barracks, located at the United States Military Academy, West Point, New York. The limited survey was performed on July 22 and 23, 2014, and September 18 and 22, 2014. The purpose of the limited hazardous materials survey was to identify asbestos-containing materials (ACM) that are present on exposed surfaces within the subject areas, and may have a significant impact on planned renovation activities, and to test for radon within the basement areas. Lead-containing materials were also identified as an item of concern however, it is our understanding that lead sampling and analysis for the project will be provided for generated waste only, prior to transfer to a regulated disposal facility. The limited hazardous materials survey procedures and report format that follow are in general compliance with applicable local, state, and federal rules and regulations.
1.2 Project Team and Certifications
Members of the ATL project team included Cheyenne J. Dashnaw, PE, Senior Engineer; R.
Daniel Faulknham, Project Manager; James J. Reber, Project Manager; and Brian J. Babcock, Senior Technician. Certifications of ATL's field survey team members and a copy of applicable company licenses maintained by ATL are included in Appendix A.
2.0 SCOPE OF WORK
2.1 Project Description
The project site is within the Pershing Barracks at the United States Military Academy, located at 600 Thayer Road, West Point, Orange County, New York. A Site Location Map, depicting the general location of the project site, is included in Appendix B.
The intent of the limited hazardous materials survey was to conduct radon testing in designated basement areas of the subject building, and to identify suspect ACM that are located within designated areas of the subject site and may be impacted during a proposed renovation project.
Pursuant to project correspondence from ATKINS, testing for lead-based paint (LBP) was not conducted. Sampling of the waste stream during the construction phase will be conducted for subsequent Toxicity Characteristic Leaching Procedure (TCLP) lead analysis.
The limited hazardous materials survey was conducted for the subject areas, as directed by Bradley Schulz, RA, representing ATKINS. The subject areas were not occupied at the time of the sampling event.
2.2 Inaccessible Areas
The extent of inaccessible areas is dependent upon the building type, construction materials, history of renovations and repairs, and project scope. Concealed materials may exist in areas that are not readily exposed to view. Although this limited hazardous materials survey was performed to identify ACM within the subject areas, potential ACM may have escaped detection that could be encountered during future building demolition and/or renovation activities. Wall, ceiling, floor, roofing, and/or other component systems may contain concealed suspect ACM. If any suspect ACM are encountered during demolition and/or renovation activities, the activities disturbing the suspect ACM must stop and the material must be sampled and laboratory analyzed in accordance with applicable regulations.
Room numbers 03, 05, 06, 09, 16A, 17, 147A, 419, 436, and 451 were not accessible at the time of the limited hazardous materials survey. Suspect ACM within these rooms would need to be assessed by a certified Asbestos Building Inspector prior to disturbance, as necessary to verify these materials are consistent with other sampled suspect ACM or to collect requisite samples.
2.3 Document Review
Documents that were provided to ATL for review during the limited hazardous materials survey included Drawing Nos. X-101, X-102, X-103, X-104, X-105, X-201, X-202, X-203, X-204, X-301, X-302, X-303, and X-304, provided by ATKINS.
2.4 Limitations
This report has been prepared in accordance with the scope of work outlined in ATL’s contract (ATL No. PT5998-10-03-14), dated March 20, 2014, and should not be used as abatement specifications or design documents. The findings, conclusions, and recommendations presented in this report are based on the field observations made by representatives of ATL and the information provided by representatives of ATKINS.
Quantities and locations of sampled materials are approximate, and should be verified by the abatement contractor(s) prior to providing actual cost quotations and/or initiating abatement activities. Variations in reported quantities and locations for sampled materials, in addition to the discovery of suspect materials not identified in this report, is possible due to the presence of inaccessible areas, as described in Section 2.2 of this report.
The findings and opinions are relevant to the dates of our site work and should not be relied on to represent conditions at substantially later dates.
3.0 ASBESTOS
3.1 Methodology
A visual examination of the subject areas was conducted by an Asbestos Building Inspector to identify suspect ACM. Functional spaces were identified to assist while locating suspect ACM.
A functional space is defined as a spatially distinct area within a building that contains identifiable populations of building occupants. A functional space may include a room, a group of rooms, or other defined area, and several functional spaces may comprise a single homogeneous sampling area. A homogeneous sampling area is defined as an area that is uniform by color, texture, construction/application, and general appearance. Each identified functional space was visually examined to determine the locations of suspect ACM. These materials were then delineated into homogeneous sampling areas.
Samples of each accessible homogeneous area were collected and placed in clean, labeled containers. The appropriate custody documentation was completed and the suspect ACM samples were submitted to AmeriSci New York (AmeriSci), located in New York, New York.
The samples were laboratory analyzed by polarized light microscopy (PLM) and transmission electron microscopy (TEM) methodologies, as applicable. AmeriSci is a New York State Department of Health (NYSDOH) certified laboratory for PLM and TEM analysis under
Environmental Laboratory Approval Program (ELAP) No. 11480. AmeriSci is also accredited by the National Institute of Standards and Technology (NIST), under the National Voluntary Laboratory Accreditation Program (NVLAP).
3.2 Regulatory Compliance
In New York State, there are multiple regulatory agencies that have jurisdiction over ACM in buildings. Asbestos survey requirements are primarily regulated or specified by the New York State Department of Labor (NYSDOL), the New York State Department of Health (NYSDOH), the Occupational Safety and Health Administration (OSHA), and the United States Environmental Protection Agency (EPA).
The NYSDOL established Part 56 of The Official Compilation of Codes, Rules, and Regulations (cited as 12 NYCRR, Part 56) to address the proper identification, handling, removal, and disposal of ACM in buildings. Asbestos survey requirements are specified in Subpart 56-5.1 “Asbestos Survey Requirements for Building/Structure Demolition, Renovation, Remodeling and Repair.” The NYSDOL also works in conjunction with the NYSDOH to establish and maintain asbestos safety training program requirements, and enforce personnel certifications and licensing protocol for asbestos contractors.
The OSHA defines requirements for asbestos surveys and identification of ACM and presumed asbestos-containing materials (PACM) in 29 CFR 1926.1101 (k) “Communication of Hazards.”
Under this regulation, OSHA makes reference to conducting inspections according to
1926.1101 (k)(5)(ii)(B) and 1926.1101 (k)(5)(iii) or pursuant to the requirements of the Asbestos Hazard Emergency Response Act (AHERA) 40 CFR Part 763, Subpart E “Asbestos-Containing Materials in Schools.” The AHERA is regulated by the EPA, and applies to primary and secondary schools only; however, the procedures mandated under AHERA are generally considered the industry standards for surveys, as these are typically the most stringent.
3.3 Summary of Findings
A total of 108 homogeneous areas of suspect ACM were identified during the visual examination, from which 254 bulk samples were collected and subsequently submitted to a NYSDOH approved laboratory for analysis. Approximate sample locations are depicted on the Sample Location Plans, contained in Appendix C. A copy of laboratory reports and sample custody documentation are contained in Appendix D. Table I below provides a summary of the identified suspect ACM and associated analytical results.
Table I Summary of Suspect ACM and Analytical Results
Material General Location
Friable
Asbestos
Condition
Sample Numbers
Estimated Quantity
3, 4
White Ceiling Plaster Skim
Coat
Throughout Entire Building, Except 2 nd and rd
Floor Side Corridors Yes NAD Fair
PT5236AI01A
PT5236AI01B
PT5236AI01C
PT5236AI01D
PT5236AI01E
PT5236AI01F
PT5236AI01G
NA
Table I (continued)
Friable
Asbestos
Condition
Sample Numbers
Estimated
Gray Ceiling Plaster Base
Coat
Throughout Entire Building, Except 2 nd and rd
Floor Side Corridors Yes NAD Fair
PT5236AI02A
PT5236AI02B
PT5236AI02C
PT5236AI02D
PT5236AI02E
PT5236AI02F
PT5236AI02G
NA
White Wall Plaster Skim
Coat
Throughout Entire Building, Except 2 nd and rd
Floor Side Corridors Yes NAD Fair
PT5236AI03A
PT5236AI03B
PT5236AI03C
PT5236AI03D
PT5236AI03E
PT5236AI03F
PT5236AI03G
NA
Gray Wall Plaster Base
Coat
Throughout Entire Building, Except 2 nd and rd
Floor Side Corridors Yes NAD Fair
PT5236AI04A
PT5236AI04B
PT5236AI04C
PT5236AI04D
PT5236AI04E
PT5236AI04F
PT5236AI04G
NA
White Sink Caulk
All Cadet Rooms No NAD Good
PT5236AI05A
PT5236AI05B
NA
Brown 6-Inch Cove Base
Room Nos. 101, 102, 103, 104, 105, 108, 110, 111, 113, 114, 120, 121, 122, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 136, 139, 141, 142, 144, 146, 201, 204, 209, 210, 211, 216, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 233, 234, 235, 237, 238, 240, 242, 243, 244, 246, 247, 250, 251, 252, 253, 301, 302, 303, 304, 305, 308, 310, 311, 312, 314, 319, 320, 321, 324, 325, 326, 327, 329, 330, 331, 332, 333, 334, 336, 337, 338, 340, 341, 343, 345, 346, 348, 351, 352, 353, 401, 402, 403, 404, 405, 408, 410, 411, 412, 413, 414, 416, 419, 420, 421, 422, 423, 424, 425, 426, 429, 430, 431, 432, 433, 434, 435, 436, 437, 438, 440, 442, 445, 446, 448, and
No NAD Good
PT5236AI06A
PT5236AI06B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Yellowish-Brown Adhesive
Associated with Brown 6-Inch Cove Base
Room Nos. 101, 102, 103, 104, 105, 108, 110, 111, 113, 114, 120, 121, 122, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 136, 139, 141, 142, 144, 146, 201, 204, 209, 210, 211, 216, 222, 223, 224, 225, 226, 227, 228, 229, 230, 231, 233, 234, 235, 237, 238, 240, 242, 243, 244, 246, 247, 250, 251, 252, 253, 301, 302, 303, 304, 305, 308, 310, 311, 312, 314, 319, 320, 321, 324, 325, 326, 327, 329, 330, 331, 332, 333, 334, 336, 337, 338, 340, 341, 343, 345, 346, 348, 351, 352, 353, 401, 402, 403, 404, 405, 408, 410, 411, 412, 413 414, 416, 419, 420, 421, 422, 423, 424, 425, 426, 429, 430, 431, 432, 433, 434, 435, 436, 437, 438, 440, 442, 445, 446, 448, and
No NAD Good
PT5236AI07A
PT5236AI07B
NA
Tan with Brown 12- by 12-Inch
Floor Tile
Room Nos. 101, 102, 103, 108, 105, 111, 112, 118, 120, 122, 123, 125, 127, 130, 131, 134, 142, 144, 202, 211, 212, 216, 220, 222, 223, 225, 229, 230, 231, 234, 238, 245, 248, 251, 253, 301, 305, 312, 314, 316, 320, 323, 325, 329, 330, 331, 334, 335, 337, 338, 342, 346, 348, 351, 352, 353, 401, 402, 408, 410, 411, 412, 414, 416, 419, 420, 422, 425, 429, 430, 431, 434, 435, 436, 437, 442, 445, 446, 448, and 451
No NAD Fair
PT5236AI08A
PT5236AI08B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Black Mastic Associated with Tan with Brown 12- by 12-Inch
Floor Tile
Room Nos. 101, 102, 103, 108, 105, 111, 112, 118, 120, 122, 123, 125, 127, 130, 131, 134, 142, 144, 202, 211, 212, 216, 220, 222, 223, 225, 229, 230, 231, 234, 238, 245, 248, 251, 253, 301, 305, 312, 314, 316, 320, 323, 325, 329, 330, 331, 334, 335, 337, 338, 342, 346, 348, 351, 352, 353, 401, 402, 408, 410, 411, 412, 414, 416, 419, 420, 422, 425, 429, 430, 431, 434, 435, 436, 437, 442, 445, 446, 448, and 451
No NAD Fair
PT5236AI09A
PT5236AI09B
NA
Light Gray with Gray 12- by 12- Inch Floor Tile
Room Nos. 101, 102, 104, 113, 121, 124, 126, 128, 129, 132, 133, 136, 139, 145, 208, 219, 221, 224, 226, 227, 228, 233, 237, 240, 242, 243, 246, 252, 303, 304, 305, 308, 310, 319, 321, 324, 326, 327, 332, 337, 340, 343, 350, 403, 404, 421, 423, 424, 426, 432, 433, 440, and 450
No NAD Fair
PT5236AI10A
PT5236AI10B
NA
Black Mastic Associated with Light Gray with Gray 12- by 12- Inch Floor Tile
Room Nos. 101, 102, 104, 113, 121, 124, 126, 128, 129, 132, 133, 136, 139, 145, 208, 219, 221, 224, 226, 227, 228, 233, 237, 240, 242, 243, 246, 252, 303, 304, 305, 308, 310, 319, 321, 324, 326, 327, 332, 337, 340, 343, 350, 403, 404, 421, 423, 424, 426, 432, 433, 440, and 450
No NAD Fair
PT5236AI11A
PT5236AI11B
NA
Gray/Tan/Beige Terrazzo Floor and Cove Base
Throughout Building Except for Basement and Stair Towers No NAD Good
PT5236AI12A
PT5236AI12B
NA
Salmon Speckled 12- by
12-Inch Floor Tile
Room Nos. 102, 338, and 442
No NAD Fair
PT5236AI13A
PT5236AI13B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Yellow/Brown Mastic
Associated with Salmon
Speckled 12- by 12-Inch Floor
Tile
Room Nos. 102, 338, and 442
No NAD Fair
PT5236AI14A
PT5236AI14B
NA
Brown Blended 12- by 12- Inch
Floor Tile
Room Nos. 102, 105, 114, 118, 123, 126, 127, 128, 131, 220, 230, 231, 238, 242, 245, 252, 304, 305, 308, 313, 319, 320, 327, 330, 337, 340, 353, 355, 404, 405, 412, 413, 414, 434, 437, 448, and 451; Stair Tower No. 5
No NAD Fair
PT5236AI15A
PT5236AI15B
NA
Yellow/Brown Mastic
Associated with Brown Blended 12- by 12- Inch
Floor Tile
Room Nos. 102, 105, 114, 118, 123, 126, 127, 128, 131, 220, 230, 231, 238, 242, 245, 252, 304, 305, 308, 313, 319, 320, 327, 330, 337, 340, 353, 355, 404, 405, 412, 413, 414, 434, 437, 448, and 451; Stair Tower No. 5
No NAD Fair
PT5236AI16A
PT5236AI16B
NA
Beige with White and Gray 12- by
12-Inch Floor Tile
Room Nos. 104, 142, 245, 252, 253, 312, 325, 335, 340, 350, and 433
No NAD Fair
PT5236AI17A
PT5236AI17B
NA
Black Mastic Associated with Beige with White and Gray 12- by
12-Inch Floor Tile
Room Nos. 104, 142, 245, 252, 253, 312, 325, 335, 340, 350, and 433
No NAD Fair
PT5236AI18A
PT5236AI18B
NA
Light Blue with Brown 12- by 12-Inch Floor
Tile
Room Nos. 104, 124, 344B, 344C, 406, 411, 412, 414, 430, and 433
No NAD Fair
PT5236AI19A
PT5236AI19B
NA
Yellow/Black Mastic
Associated with Light Blue with Brown 12- by 12-Inch Floor
Tile
Room Nos. 104, 124, 344B, 344C, 406, 411, 412, 414, 430, and 433
No NAD Fair
PT5236AI20A
PT5236AI20B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Gray Blended 12- by 12-Inch
Floor Tile
Room Nos. 110, 118, 123, 125, 131, 138, 211, 214, 229, 238, 242, 243, 244, 250, 251, 253, 301, 308, 323, 330, 331, 333, 340, 344, 357, 401, 402, 414, 421, 422, 423, and
No NAD Fair
PT5236AI21A
PT5236AI21B
NA
Yellow/Black Mastic
Associated with Gray Blended 12- by 12-Inch
Floor Tile
Room Nos. 110, 118, 123, 125, 131, 138, 211, 214, 229, 238, 242, 243, 244, 250, 251, 253, 301, 308, 323, 330, 331, 333, 340, 344, 357, 401, 402, 414, 421, 422, 423, and
No NAD Fair
PT5236AI22A
PT5236AI22B
NA
Gray with Brown 12- by 12-Inch
Floor Tile
Room Nos. 114, 119, 142, 215, 231, 234, 404 and 431 No NAD Fair
PT5236AI23A
PT5236AI23B
NA
Yellow/Black Mastic
Associated with Gray with Brown 12- by 12-Inch
Floor Tile
Room Nos. 114, 119, 142, 215, 231, 234, 404 and 431 No NAD Fair
PT5236AI24A
PT5236AI24B
NA
Tan with White Terrazzo Floor, Cove Base, and
Stair Tread
All Four Levels of Stair Towers
No NAD Fair
PT5236AI25A
PT5236AI25B
NA
Tan with Brown and White 12- by
12-Inch Floor Tile
Room Nos. 120, 146, 202, 203, 204, 214, 250, 342, 344C, 445, and 452A
No NAD Fair
PT5236AI26A
PT5236AI26B
NA
Black Mastic Associated with Tan with Brown and White 12- by 12-Inch Floor
Tile
Room Nos. 120, 146, 202, 203, 204, 214, 250, 342, 344C, 445, and 452A
No NAD Fair
PT5236AI27A
PT5236AI27B
NA
Gray Exterior Ceiling Plaster
Room No. 127A and Vestibule No. 4B
Yes NAD Fair
PT5236AI28A
PT5236AI28B
PT5236AI28C
NA
White Floor Leveler
Room No. 127 at Door Threshold
Yes NAD Fair
PT5236AI29A
PT5236AI29B
NA
Tan with Brown and White 12- by
12-Inch Floor Tile
Room Nos. 130 and 342 No NAD Fair
PT5236AI30A
PT5236AI30B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Yellow/Black
Associated with Tan with Brown and White 12- by 12-Inch Floor
Tile
Room Nos. 130 and 342 No NAD Fair
PT5236AI31A
PT5236AI31B
NA
Beige with Brown/White/Gr ay 12- by 12- Inch Floor Tile
Room Nos. 132, 303, 325, and 440
No NAD Fair
PT5236AI32A
PT5236AI32B
NA
Black Mastic Associated with
Beige with Brown/White/Gr ay 12- by 12- Inch Floor Tile
Room Nos. 132, 303, 325, and 440
No NAD Fair
PT5236AI33A
PT5236AI33B
NA
White Grout Associated with
4- by 4-Inch Ceramic Wall
Tile
Bathrooms and Shower Rooms
Yes NAD Fair
PT5236AI34A
PT5236AI34B
NA
Gray Mortar Bed Associated with
4- by 4-Inch Ceramic Wall
Tile
Bathrooms and Shower Rooms
Yes NAD Fair
PT5236AI35A
PT5236AI35B
NA
Gray Grout Associated with
Gray Mosaic Ceramic Floor
Tile
Room Nos. 07, 11B, 11C, 15, 15A, 19, 107, 107A, 117, 135, 143, 143A, 207, 207A, 217, 239, 247, 247A, 307, 307A, 307B, 307C, 318, 339, 347, 347A, 347B, 347C, 347D, 407, 407A, 417, 439, 447, 447A
Yes NAD Fair
PT5236AI36A
PT5236AI36B
NA
Gray Grout Associated with
1- by 1-Inch Ceramic Floor
Tile
Shower Rooms Yes NAD Fair
PT5236AI37A
PT5236AI37B
NA
Gray Grout Associated with Mosaic Ceramic
Floor Tile
Stair No.1 Yes NAD Fair
PT5236AI38A
PT5236AI38B
NA
Gray Grout Associated with
4- by 8-Inch Glazed Ceramic
Wall Tile
Room Nos. 08, 11, 14, 16, and 147
Yes NAD Fair
PT5236AI40A
PT5236AI40B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Black 6-Inch Cove Base
Room Nos. 203, 204, 205, 208, 210, 211, 212, and 214 No NAD Fair
PT5236AI41A
PT5236AI41B
NA
Tan/Yellow Adhesive
Associated with Black 6-Inch Cove Base
Room Nos. 203, 204, 205, 208, 210, 211, 212, and 214 No NAD Fair
PT5236AI42A
PT5236AI42B
NA
White with Gray and Blue 12- by 12-Inch Floor
Tile
Room Nos. 205 and 210 No NAD Fair
PT5236AI43A
PT5236AI43B
NA
Amber/Yellow Mastic
Associated with White with Gray and Blue 12- by 12-Inch Floor
Tile
Room Nos. 205 and 210 No NAD Fair
PT5236AI44A
PT5236AI44B
NA
White Bathroom Fixture Caulk
Bathrooms No NAD Good
PT5236AI45A
PT5236AI45B
NA
Blue and White Blended 12- by 12-Inch Floor
Tile
Room Nos. 212 and 401 No NAD Fair
PT5236AI46A
PT5236AI46B
NA
Black/Amber Mastic
Associated with Blue and White Blended 12- by 12-Inch Floor
Tile
Room Nos. 212 and 401 No NAD Fair
PT5236AI47A
PT5236AI47B
NA
Light Blue with White Blended 12- by 12-Inch
Floor Tile
Room Nos. 212 and 253 No NAD Fair
PT5236AI48A
PT5236AI48B
NA
Black/Amber Mastic
Associated with Light Blue with White Blended 12- by 12-Inch
Floor Tile
Room Nos. 212 and 253 No NAD Fair
PT5236AI49A
PT5236AI49B
NA
Red Firestop Room Nos. 4A, 9A, 11, 115, 137, 215, 241, 315, 341, 415, and 441
No NAD Good
PT5236AI50A
PT5236AI50B
NA
Light Gray with Multicolor 12- by
12-Inch Floor Tile
Room Nos. 220, 235, 350, 351, and 437
No NAD Fair
PT5236AI51A
PT5236AI51B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Black/Amber
Associated with Light Gray with
Multicolor 12- by 12-Inch Floor
Tile
Room Nos. 220, 235, 350, 351, and 437
No NAD Fair
PT5236AI52A
PT5236AI52B
NA
Tan Blended 12-by 12-Inch Floor
Tile
Room Nos. 252, 319, and 444
No NAD Fair
PT5236AI53A
PT5236AI53B
NA
Black Mastic Associated with Tan Blended 12-by 12-Inch Floor
Tile
Room Nos. 252, 319, and 444
No NAD Fair
PT5236AI54A
PT5236AI54B
NA
Dark Gray with White 12- by 12- Inch Floor Tile
Room No. 253 and Elevator
No NAD Fair
PT5236AI55A
PT5236AI55B
NA
Amber/Black Mastic
Associated with Dark Gray with
White 12- by 12- Inch Floor Tile
Room No. 253 and Elevator
No NAD Fair
PT5236AI56A
PT5236AI56B
NA
White with Dark and Light Gray 12- by 12-Inch
Floor Tile
Room Nos. 342 and 450 No NAD Fair
PT5236AI57A
PT5236AI57B
NA
Amber/Black Mastic
Associated with White with Dark and Light Gray 12- by 12-Inch
Floor Tile
Room Nos. 342 and 450 No NAD Fair
PT5236AI58A
PT5236AI58B
NA
Gray with Dark Gray and White 12- by 12-Inch
Floor Tile
Room No. 340 No NAD Fair
PT5236AI59A
PT5236AI59B
NA
Black Mastic Associated with Gray with Dark Gray and White 12- by 12-Inch
Floor Tile
Room No. 340 No NAD Fair
PT5236AI60A
PT5236AI60B
NA
Moth with White Blended 12- by 12-Inch Floor
Tile
Room No. 351 No NAD Fair
PT5236AI61A
PT5236AI61B
Friable
Asbestos
Condition
Sample Numbers
Estimated
Amber/Black
Associated with Moth with White Blended 12- by 12-Inch Floor
Tile
Room No. 351 No NAD Fair
PT5236AI62A
PT5236AI62B
NA
Gray Gypsum Board
Room Nos. 429 and 501; 2 nd and 3 rd Floor
Side Corridors Yes NAD Good
PT5236AI63A
PT5236AI63B
NA
White Joint Compound
Room Nos. 429 and 501; 2 nd and 3 rd Floor
Side Corridors Yes NAD Good
PT5236AI64A
PT5236AI64B
NA
Black Vapor Barrier
Room No. 501 (Under Carpet)
No NAD Fair
PT5236AI65A
PT5236AI65B
NA
Brown Cement- Like Floor Fill
Material
Various Areas Throughout Building
Yes NAD Poor
PT5236AI66A
PT5236AI66B
NA
Tan 6-Inch Cove Base
Room Nos. 452 and 452A
No NAD Good
PT5236AI67A
PT5236AI67B
NA
Brown/Tan/Yello w Adhesive
Associated with Tan 6-Inch Cove
Base
Room Nos. 452 and 452A
No NAD Good
PT5236AI68A
PT5236AI68B
NA
Brown Residual Chalkboard Adhesive
Room Nos. 452 and 452A
No NAD Fair
PT5236AI69A
PT5236AI69B
NA
Black Residual Chalkboard Adhesive
Room Nos. 452 and 452A
No 4.5 Fair
PT5236AI70A
PT5236AI70B
Square
Feet
Green Wardrobe Flooring
All Cadet Rooms No NAD Good
PT5236AI71A
PT5236AI71B
NA
White Fiberglass Thermal System Insulation (TSI)
Jacket
Throughout Structure No NAD Fair
PT5236AI72A
PT5236AI72B
PT5236AI72C
NA
White TSI Pipe End Sealant
Throughout Structure No NAD Fair
PT5236AI73A
PT5236AI73B
PT5236AI73C
NA
White TSI Tank Lag Cloth
Room No. 02A No NAD Fair
PT5236AI74A
PT5236AI74B
PT5236AI74C
NA
Gray Plaster Wall Patch
Room Nos. 07, 08, and 08A
Yes NAD Fair
PT5236AI75A
PT5236AI75B
PT5236AI75C
NA
White Vibration Cloth
Room No. 07 Yes NAD Fair
PT5236AI77A
PT5236AI77B
NA
White Duct Jacket
Room No. 07 Yes NAD Fair
PT5236AI78A
PT5236AI78B
PT5236AI78C
Friable
Asbestos
Condition
Sample Numbers
Estimated
Gray Duct Sealant
Above Ceiling in 4 th
Floor Corridor No NAD
PT5236AI79A
PT5236AI79B
NA
Brown with Tan and Black Small
Aggregate Terrazzo Flooring
Room Nos. 08, 08A, 11, 11A, and 14
No NAD Fair
PT5236AI80A
PT5236AI80B
NA
Black Residual Mastic
Room No. 08A No NAD Fair
PT5236AI81A
PT5236AI81B
NA
White Firestop Room No. 08A Yes NAD Good
PT5236AI82A
PT5236AI82B
NA
White Window Caulk
Room No. 11 No NAD Fair
PT5236AI83A
PT5236AI83B
NA
Black Tar on Pipe
Room Nos. 11, 12A, 14, 23A, 24, 24A, and 25A
No NAD Fair
PT5236AI84A
PT5236AI84B
NA
Black Floor Patch
Room Nos. 20, 20A, 22, 23, 24, 24A, and 25
No NAD Fair
PT5236AI85A
PT5236AI85B
NA
Beige Pipe Caulk
Room No. 25A No NAD Fair
PT5236AI86A
PT5236AI86B
NA
Black Vapor Barrier
Throughout Structure No NAD Fair
PT5236AI87A
PT5236AI87B
NA
Gray Flashing Caulk
Associated with Gray Metal Flashing
Roof Flashing No NAD Fair
PT5236AI88A
PT5236AI88B
NA
Silver Flashing Paint
Roof Flashing No Trace Fair
PT5236AI89A
PT5236AI89B
NA
White Flashing Caulk
Associated with Gray Metal Flashing
Roof Flashing No Trace Fair
PT5236AI90A
PT5236AI90B
NA
Beige Perimeter Caulk
Vents and Roof Penetrations
No NAD Fair
PT5236AI91A
PT5236AI91B
NA
White Caulk Associated with
Green Metal Roofing
Roof Flashing No Trace Fair
PT5236AI92A
PT5236AI92B
NA
Dark Gray Window Caulk
Window to Room No.
501 and Stair Tower
Windows No NAD Fair
PT5236AI93A
PT5236AI93B
NA
Gray/Black Asphalt Roof Membrane
Roof No NAD Fair
PT5236AI94A
PT5236AI94B
NA
Black Felt Paper Roof No NAD Fair
PT5236AI95A
PT5236AI95B
NA
Brown Fiberboard
Roof Yes NAD Fair
PT5236AI96A
PT5236AI96B
Friable
Asbestos
Condition
Sample Numbers
Estimated
White/Gray Flashing
Membrane Roof No NAD Fair
PT5236AI97A
PT5236AI97B
NA
White Adhesive Associated with
White/Gray Flashing
Membrane
Roof No NAD Fair
PT5236AI98A
PT5236AI98B
NA
Black/Gray Flashing Patch
Membrane Roof No NAD Fair
PT5236AI99A
PT5236AI99B
NA
Dark Gray Window Caulk
Basement and 1 st Floor
Windows No NAD Fair
PT5236AI100A
PT5236AI100B
NA
Gray Door Caulk
Room No. 147; Corridor No. 1A; Vestibule No.
04B; Stairwell 1, 2, 3, and 4
No NAD Fair
PT5236AI101A
PT5236AI101B
NA
Gray Exterior Window Caulk nd
, 3 rd
, and 4 th
Floor Windows
No NAD Fair
PT5236AI102A
PT5236AI102B
NA
Light Gray Expansion Caulk
Corridor No. 01A to Vestibule No. 4B
(Exterior) No NAD Fair
PT5236AI103A
PT5236AI103B
NA
Tan Floor Tile st and 2 nd Floor Cadet
Rooms Below Plywood
No 6.6 Fair
PT5236AI104A
PT5236AI104B
20,486 Square
Feet
Black Floor Tile Mastic/Vapor
Barrier st and 2 nd Floor Cadet
Rooms Below Plywood
No Trace Fair
PT5236AI105A
PT5236AI105B
NA
Black/Brown Vapor Barrier rd and 4 th Floor Cadet
Rooms No NAD Fair
PT5236AI106A
PT5236AI106B
NA
White Ceiling Plaster Skim
Coat at Upper Ceiling
Above Plaster Ceiling on nd , 3 rd , and 4 th Floors
Yes NAD Poor
PT5236AI107A
PT5236AI107B
PT5236AI107C
PT5236AI107D
PT5236AI107E
PT5236AI107F
PT5236AI107G
NA
Gray Ceiling Plaster Base Coat at Upper
Ceiling
Above Plaster Ceiling on nd , 3 rd , and 4 th Floors
Yes NAD Poor
PT5236AI108A
PT5236AI108B
PT5236AI108C
PT5236AI108D
PT5236AI108E
PT5236AI108F
PT5236AI108G
Friable
Asbestos
Condition
Sample Numbers
Estimated
Gray TSI Mudded Fitting
Wet Wall Associated with Bathrooms
6 Yes 50.0 Fair
PT5236AI109A
PT5236AI109B
PT5236AI109C
20 Square Feet
Brown Layer Paper TSI
Wet Wall Associated with Bathrooms
6 Yes 12.1 Fair
PT5236AI110A
PT5236AI110B
PT5236AI110C
Square
Feet
Notes:
Sample Location Plans are enclosed in Appendix C.
NAD = No Asbestos Detected
Quantities and locations are approximate and must be verified by asbestos abatement contractors prior to providing actual cost quotations and/or initiating abatement activities.
NA = Not Applicable
Tan Floor Tile and Black Floor Tile Mastic/Vapor Barrier were observed below a layer of plywood flooring in Room Nos. 105 and 220 at the time of the limited hazardous materials survey sampling event. These materials may exist in additional cadet rooms on the 1 st and 2 nd floors.
Material was accessible and/or visible in the 2 nd , 3 rd , and 4 th floor bathrooms. Material was not accessible in the wet walls on the st Floor and Basement Level and may exist in additional areas on these levels.
The EPA, NYSDOL, and other regulatory agencies define ACM as any material containing greater than 1% of asbestos. Materials listed in bold font in Table I above were determined to be ACM.
Materials containing trace asbestos (i.e., less than 1%) are not considered ACM; however, the OSHA recognizes materials that contain trace amounts of asbestos, and requires these materials be handled in accordance with their standard interpretation letter titled “Requirements for demolition operations involving material containing <1% asbestos “, dated August 13, 1999.
As shown in Table I above, 4 materials were determined to contain trace amounts of asbestos.
4.0 RADON
4.1 Methodology
A visual examination of the subject areas was conducted by an Environmental Scientist to identify areas with a higher potential for radon migration, if present, based on location relative to subsurface soil/rock and conditions of building materials for areas in contact with subsurface soil/rock. Since the conditions of building materials were observed to be relatively consistent, six sample locations were randomly selected from rooms in the basement area that are in direct contact with subsurface soil/rock. The basement area is the lowest occupied space of the subject building. Short duration (2-4 days) radon test kits were used to detect concentrations of radon in picocuries per liter (pCi/L) of air.
Test kits were placed and remained on-site for duration of 4 days. After the 4-day period, the samples were collected and submitted to Airchek, Inc., located in Mills River, North Carolina.
The samples were laboratory analyzed for radon, in accordance with applicable methods.
Airchek, Inc., is a NYSDOH approved laboratory under Environmental Laboratory Approval Program (ELAP) No. 11441.
4.2 Summary of Findings
The six radon samples, placed in the basement area of the subject building, were collected and subsequently submitted to a NYSDOH ELAP approved laboratory for analysis. Approximate sample locations are depicted on the Sample Location Plans, contained in Appendix C. A copy of laboratory reports and associated sample custody documentation are contained in Appendix D. Table II below provides a summary of the radon sample location and analytical results.
Table II Summary of Suspect LBP and Analytical Results
General Location Sample
Numbers Laboratory Results
(pCi/L)
Steam Room 01 PT5236RB01 <0.3
Trunk Room 010 PT5236RB02 1.2 +/- 0.2
Electrical Service Room 013 PT5236RB03 1.6 +/- 0.2
Mountaineering 017 PT5236RB04 0.7 +/- 0.1
Trunk Room 025 PT5236RB06 <0.3
Trunk Room 023a PT5236RB05 <0.3
The United States Environmental Protection Agency (EPA) has identified an action level for the concentration of radon in homes and commercial buildings at 4.0 pCi/L. The EPA recommends that corrective action be taken to reduce radon levels below 4.0 pCi/L. The EPA also suggests that corrective action be taken at radon levels between 2.0 pCi/L and 4.0 pCi/L. Typical outdoor background exposure to radon is 0.4 pCi/L.
None of the samples collected were determined to be at or above action level, as identified by the EPA. Radon was detected for 3 of the 6 collected samples, at concentrations ranging between 0.7 and 1.6 pCi/L.
5.0 LEAD-CONTAINING MATERIALS
Pursuant to project correspondence between ATL and ATKINS, an assessment for lead-containing materials was not conducted during the limited hazardous materials survey. It is our understanding that sampling and analysis for lead in the waste stream to be generated during renovations will be performed at the start of the construction phase. Representative samples of the waste stream will be collected and submitted for Toxicity Characteristic Leaching Procedure (TCLP) lead analysis. Based on the selected on the selected methods for management of potential lead-containing materials, any suspect lead-containing materials shall be assumed to contain lead and appropriately managed during the renovation work activities.
6.0 CONCLUSIONS AND RECOMMENDATIONS
The following conclusions and recommendations are prepared from ATL’s understanding that the subject building may be subject to renovation projects. Should the management of the building areas change, it is recommended that the findings be revisited to reflect appropriate operations and management practices for ACM and radon within buildings.
6.1 Asbestos-Containing Materials
1. Concealed regulated ACM may exist at the site that could be encountered during future building renovation activities. Wall, ceiling, floor, roofing, and/or other component systems may contain concealed suspect ACM. If any suspect ACM is encountered during demolition and/or renovation activities, the activities disturbing the suspect ACM must stop and the material must be sampled and laboratory analyzed in accordance with applicable regulations.
2. The materials listed in bold in Table I of Section 3.3 were determined to be ACM. The referenced table also shows materials that contain trace concentrations of asbestos and are regulated under OSHA.
3. Subpart 56-5(h) of 12 NYCRR Part 56 requires that no demolition, renovation, remodeling, or repair work be commenced by any owner or the owner’s agent prior to the completion of asbestos abatement. Asbestos abatement must be performed by an asbestos abatement contractor that maintains a current asbestos handling license, and employs NYSDOL certified asbestos handlers and supervisors. It is recommended that a 12 NYCRR 56 certified Project Monitor oversee abatement activities.
4. Subpart 56-5(g) of 12 NYCRR Part 56 specifies requirements for transmittal of asbestos survey information by the owner or owner’s agent. One copy of the asbestos survey report shall be sent to the local government entity charged with issuing a permit for such demolition, renovation, remodeling, or repair work under applicable State or local laws. If controlled demolition or pre-demolition activities will be performed, one copy of the asbestos survey report shall be submitted to the appropriate Asbestos Control Bureau district office.
One copy of the asbestos survey report must be kept on the construction site throughout the duration of the asbestos project and any associated demolition, renovation, remodeling, or repair project.
6.2 Radon
1. None of the 6 samples collected were determined to be at or above action levels identified by EPA. There was radon detected in 3 of the 6 samples at concentrations ranging between
0.7 and 1.6 pCi/L. Based on the detected presence of radon, it is recommended that the building be periodically tested for radon levels, especially as building materials adjacent to subsurface soil/rock start to crack or deteriorate and after any building renovations that may increase the potential for radon migration.
2. Should corrective action be chosen to reduce the detectable concentration of radon, remediation should be managed in accordance with applicable EPA guidelines and completed by experienced and qualified contractors.
6.3 Lead-Containing Materials
1. As indicated in Section 5.0, representative samples of the waste stream to be generated during renovations will be performed at the start of the construction phase. Based on the selected methods for management of potential lead-containing materials, any suspect lead-containing materials shall be assumed to contain lead and appropriately managed during the renovation work activities.
A
APPENDIX A
LICENSES AND CERTIFICATIONS
other on file
Asbestos Certificate Code Classifications
The following letter codes shown on the enclosed asbestos certificates represent the corresponding asbestos classifications:
A - Asbestos Handler F - Operations & Maintenance B - Allied Trades G - Asbestos Supervisor C - Air Sampling Technician H - Asbestos Project Monitor D - Building Inspector I - Asbestos Project Designer E - Management Planner
Ny(AP- ^."u"W""\..ffi;National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
AmeriSci New York DBA: AmeriSci New York
117 E. 30th Street NewYork,NY 10016
Mr. Paul Mucha Phone: 212-679-8600 Fax: 212-679-27 11
E-Mail : pmucha@amerisci.com URL: http://rwr,v.amerisci.com
BULK ASBESTOS FIBER ANALYSIS (PLM) NVLAPLABCODE 200546-0
Designation / Description
EPA 600/M4-82-020: Interim Method for the Determination of Asbestos in Bulk Insulation Samples
EPA 600,R-93/116: Method for the Determination of Asbestos in Bulk Building Materials
NVI.IIP Code
18/A01
18/A03
Effective dates
Page 1of 1
201 4-07 -01 through 20 I 5-06-30 tu fl ,tl,t-LQ For the National lnstitute of Standards and Technology
NVLAP-o1S (REV. 2005.05-19)
UI
v.
(J o-l z o.)
o e e o
(D a q
a) ltt
(g oa q)
,P
?s
SI
FE
N b fl FE' Y F a
^t o sa' u E { 8 , E A O N
E { S tI ; . E e r g E E G : O E 6 i E > 6 e * 5 - ) E ; ' d o ^ Q H { E t s s # i : e F s SE 5 E * J E F sR F > - E * X i E s. : i > z E H f , . s x . .
e a r u S t = b t s 5 z E S € I - R I g : ' 5 F E $ k [ t + 3 ? i ! { F i s a ; i z F e 3 : B E I E S i E H E * = 2 -i e E V T i E' ) i I . \< c )
- h -c e * t i* -i . F x 8x x ;
E i r 8 E Q" i F e
- * E
- . p l'-sd^- ""'z iFffi} z t'- 6 tn* r uono ut g) o a q) h
F-
N
ItO o oql 1() o N F
O
IIJ
o I o c o t -
{r,(E .E !t o l-o o lts o o
{d(u o t -tF.E L oo
@ - l t=l!
E:J I z t o)o ,cl 6 o - c t r o E P 9 o\., c tF Cto o t s E o c t t r E
F So-u, O u -o o o o o = g E A o
- c o -t ( s c c : . 9 z
B
APPENDIX B
SITE LOCATION MAP
Site Location Map Drawn by:
JJR
Scale:
Not to scale
Project No.:
PT5236
Date:
November 2014
West Point Military Academy Pershing Barracks 600 Thayer Road
West Point, Orange County, New York
ATLANTIC TESTING LABORATORIES, Limited Albany, NY Binghamton, NY Canton, NY Elmira, NY Plattsburgh, NY
Poughkeepsie, NY Syracuse, NY Rochester, NY Utica, NY Watertown, NY
Project Site
C
APPENDIX C
SAMPLE LOCATION PLANS
ATL Report No. PT5136CE-01-11-14
D
APPENDIX D
LABORATORY REPORTS AND CUSTODY DOCUMENTATION
U@'fFwM.u,/ AuenLScr
AmeriSci New York
1 17 EAST 3OTH ST.
NEW YORK, NY 10016
rEL: (212) 679-8600 , FM: (212) 679-3114
PLM Bulk Asbestos Report Atlantic Testing Laboratories, Limited Date Received 071291L4 AmeriSci Job # 2L4075800
Attn: James Reber Date Examined 07131114 P.O. # 5236-01 to 5236-18
P.O. Box 29 ELAP # 11480 Page 1 of 41
RE: PT5236; Pershing Barracks; West Point, NY
Canton, NY 13617
Glient No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236AI01A 214075800-01 /Vo NAD
01 Location: 43SAlWhiteSkim CoatOf PlasterCeiling (byNYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|01B 214075800-02 /Vo NAD
01 Location: Room 447 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|01C 214075800-03 No NAD
01 Location: Stair # 1 @ 3rd Level / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AI01D 214075800-04 IVo NAD
01 Location: Room 349 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|01E 214075800-05 No NAD
01 Location: Room247 /WhiteSkimCoatOf PlasterCeiling (byNYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 100 %
See Reporting notes on last page
AmeriSci Job #: 214075800
Client Name: Atlantic Testing Laboratories, Limited
PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236AI01F 214075800-06 IVo NAD
01 Location: Room 11 / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|01G 214075800-07 No NAD
01 Location: Stair # 4 @ Basement / White Skim Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O2A 214075800-08 No NAD
OZ Location: 438A tGray Base Coat Of Plaster Ceiling (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|02B 214075800-09 /Vo NAD
02 Location: Room 447 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 1 98.1 ) by Tara L. Fisher on 07 131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AI02C 214075800-10 A/o NAD
02 Location: Stair#1@3rdLevel/GrayBaseCoatOf PlasterCeiling (byNYSELAP198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AIO2D 214075800-11 /Vo NAD
02 Location: Room 349 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 1 98.1 ) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
PLM Bulk Asbestos RePort PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236A|O2E 214075800-12 No NAD
02 Location: Room 247 / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) bY Tara L. Fisher on 07 131114
Analyst Description: Grey, Homogeneous, Non-Fibrous' Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AIO2F 214075800-13 /Vo NAD
02 Location: Room 1 1 t Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) by Tara L. Fisher on 07131114
Anatyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|02G 214075800-14 No NAD
02 Location: Stair # 4 @ Basement Level / Gray Base Coat Of Plaster Ceiling (by NYS ELAP 198'1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AIO3A 214075800-15 /Vo NAD
03 Location: Room 19 / Wht. Skim coat @ walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AI03B 214075800-16 /Vo NAD
03 Location: Room 131 / Wht. Skim coat @ walls (by NYS ELAP 198.1) bY Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O3C 214075800-17 /Vo NAD
03 Location: Room '134A / WhL Skim Coat @ Walls (by NYS ELAP 198'1) bY Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
See Reporting notes on last Page
PLM Bulk Asbestos RePort PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos
PT52364l03D
214075800-18 Location: Room 296 / Wht. Skim Coat @ Walls
No NAD (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous' Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|03E 214075800-19 A/o NAD
03 Location: Room301 /Wht.Skimcoat@walls (byNYSELAP198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O3F 214075800-20 A/o NAD
03 Location: Room306/Wht.skimcoat@walls (byNYSELAP198.1) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236AIO3G 214075800-21 /Vo NAD
03 Location: Room 420 / Wht. Skim coat @ walls (by NYS ELAP 198.1) by Tara L. Fisher on 07 131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O4A 214075800-22 IVo NAD
04 Location: Room 19 / Gray Base Coat @ Walls (by NYS ELAP 198.1) bY Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O4B 214075800-23 A/o NAD
04 Location: Room 131 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236A|04C 214075800-24 IVo NAD
04 Location: Room 134A / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O4D 214075800-25 A/o NAD
04 Location: Room 296 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|04E 214075800-26 /Vo NAD
04 Location: Room 301 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|O4F 214075800-27 IVo NAD
04 Location: Room 306 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 7o
PT5236A|04G 214075800-28 No NAD
04 Location: Room 420 / Gray Base Coat @ Walls (by NYS ELAP 198.1) by Tara L. Fisher on 07131114
Analyst Description: Grey, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Typesl Other Material: Non-fibrous 100 %
PT5236A|O5A 214075800-29 Alo NAD
05 Location: Room 124 / Wht. Sink Caulk (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material
Asbestos Types:
Other Material : Non-fibrous 2.2 o/o
AmeriSci Job #: 2'1407 5800
PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos PT5236A|05B 214075800-30 No NAD 05 Location: Room 227 / wht. Sink Caulk (by NyS ELAP i 98.6) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 0.4 %
PT5236A|06A 214075800-31 No NAD 06 Location: Room 230 / 6" Brown Cove Base (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Brown, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 35.4 %
PT5236A|06B 214075800-32 No NAD 06 Location: Room 114 / 6" Brown Cove Base (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Brown, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 34 %
PT5236A|07A 214075800-33 AIo NAD 07 Location: Room 230 / Yellowish Brown Adhesive (by NYS ELAP 193.6) by Tara L. Fisher on 07131114
Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 21 .6 o/o
PT5236A|07B 214075800-34 /Vo NAD 07 Location: Room 114 / Yellowish Brown Adhesive (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 10.2 o/o
PT5236A|08A 214075800-35 IVo NAD 08 Location: Room 142 lfanWlBrown 12x12 FloorTile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 9.3 %
PageT of 41
PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY
Client No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236A|08B 214075800-36 /Vo NAD
08 Location: Room 334 lTantNl Brown 12x12 Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 13.2 o/o
PT5236AI09A 214075800-37 No NAD 09 Location: Room 142 / Black Mastic Assoc. W/ 08 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 12.1 o/o
PT5236A|09B 214075800-38 No NAD 09 Location: Room 334 / Black Mastic Assoc. W/ 08 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 1.2 o/o
PT5236A|10A 214075800-39 No NAD
10 Location: Room 130 / Lt. Gray W/ Gray Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 7 .1 o/o
PT5236A|10B 214075800-40 No NAD 10 Location: Room 332 / Lt. Gray W/ Gray Floor Tile (by NYS ELAP 198.6) byTara L. Fisher on 07131114
Analyst Description: White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 0.8 %
PT5236A|11A 214075800-41 No NAD 11 Location: Room 130 / Black Mastic Assoc. W/ 10 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 3.6 %
PLM Bulk Asbestos Report PT5236; Pershing Barracks; West Point, NY
CIient No. / HGA Lab No. Asbestos Present Total % Asbestos
PT5236Al1'tB 214075800-42 No NAD
11 Location: Room # 332 / Black Mastic Assoc. W/ 10 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Black, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 7.6 %
PT5236A|12A 214075800-43 No NAD
12 Location: 218A I Gray / Tan / Beige Terrazzo Floor (by NYS ELAP 198.1 ) by Tara L. Fisher on 07131114
Analyst Description: Brown/Grey, Homogeneous, Non-Fibrous, Cementitious, Bulk Material
Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|12B 214075800-44 IVo NAD
12 Location: 101A I Gray / Tan / Beige f enazzo Floor & Cove Base (by NYS ELAP 198.1 ) by Tara L. Fisher on 07131114
Analyst Description: Grey/Brown, Homogeneous, Non-Fibrous, Cementitious, Bulk Material Asbestos Types:
Other Material: Non-fibrous 100 %
PT5236A|13A 214075800-45 /Vo NAD
13 Location: Room 102 / Salmon Speckled l2xl2FloorTile (by NYS ELAP 198.6) by Tara L. Fisher on 07 131114
Analyst Description: Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 0.4 %
PT5236AI13B 214075800-46 No NAD
1 3 Location: Room 442 / Salmon Speckled 12x12 Floor Tile (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst Description: Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:
Other Material: Non-fibrous 1.1 %
PT5236A|14A 214075800-47 /Vo NAD
14 Location: Room 102 / Yellow / Brown Mastic W/ 13 (by NYS ELAP 198.6) by Tara L. Fisher on 07131114
Analyst…