700_series.pdf

PDF 4 MB Posted

Attached to
2989 Floating Crane Barge Federal contract opportunity
Solicitation number
W912BU19B0005
Issued by
Department of the Army Corps of Engineers Engineering District Philadeplhia

About this file

Drawing Package 5 of 5

View the file

Other files for this federal contract opportunity

Other files attached to 2989 Floating Crane Barge, newest first.
File Type Posted
Sign_In_Sheet.pdf PDF
19B0005_Abstract_(Audited)(KO).pdf PDF
W912BU19B00050005.pdf PDF
W912BU19B00050004.pdf PDF
W912BU19B00050003.pdf PDF
380-427_series.pdf PDF
100_series.pdf PDF
200-330_series.pdf PDF
500-600_series.pdf PDF
W912BU19B00050002.pdf PDF
W912BU19B0005_01.pdf PDF
Q_and_A-12Aug19.pdf PDF
850-B405-01_Cathodic_Protection.pdf PDF
850-B406-01_MDC_STANDARD_FLOATING_PLANT_PAINT_SCHEDULE.pdf PDF
DRAWING_2.pdf PDF
DRAWINGS_3.pdf PDF
DRAWINGS_4.pdf PDF
DRAWINGS_1.pdf PDF
DRAWINGS_5.pdf PDF
W912BU19B0005.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABS Global Engineering 800 West Commerce Road, Suite 400 | Harahan, LA 70123 USA

Task – T1819252, 1819253 & 1819995 TAI Crane Barge – 160’ Crane Barge ABS Pre-Contact Design Review prior to

Request for Class Flag: United States of America

Attention: Mr. Krishna Karri, Technology Associates, Inc. (WCN: 426181)

The documents shown in the attached list are reviewed in accordance with the applicable requirements of the following:

• ABS Rules for Building and Classing Steel Barges 2018, as amended

• International Convention on Load Lines 1966, as amended

Please note our review is based on the following conditions:

1. We recognize that the submitted drawings are intended for basic design only. As such, the subject review has been focused on verifying compliance reflective of the detail shown in the submitted drawing and identifying noncompliance items with the applicable Rules and Code(s) listed above. Review for full compliance with the

Rules and Code(s), such as complete Bill of Materials for piping, valves and specialty items and certificates/cut sheets for system components is to be carried out during the review of the detail design.

2. Once the vessel is contracted for construction, the drawing is to be resubmitted to

ABS for detailed review for Classification.

Additionally, we have received your declaration stating that the materials used in the system indicated in the submittal are free from asbestos.

For any clarifications, contact Khue Le at 504-262-5249, (kle@eagle.org).

Very truly yours, Roy H. Bleiberg Vice President of Engineering

Electronically Signed by: Clayton S. Cooper

Electronically published by ABS New Orleans.

Reference T1819995, dated 23-JAN-2019.

800 West Commerce Road, Suite 400 | Harahan, LA 70123 USA

Documents List

Drawing No.

Rev.

No.

Title Status

850-B399-01 0 ABS Structural

Calculations

Filed by ABS for Reference Only

850-B554-01 0 Spud Handling System Arrangements

Filed by ABS for Reference Only

850-B415-02 0 Hatches and

Manholes

Filed by ABS for Reference Only

850-B730-03 0 Navigation Lighting

Arrangements

File by ABS for Reference Only

Electronic copies of the documents, appropriately stamped, are available in the ABS My

Eagle Portal through Engineering Manager.

Reference T1819995, dated 23-JAN-2019.

See A

BS N

ew O rle ans L ette r R ef T

1819620 D ate d 1 5-J

AN

-2 ew O rle ans L ette r R ef T

1819620 D ate d 1 5-J

AN

ew O rle ans L ette r R ef T 1819995 D ate d 2

3-J

AN

S ee

A B S N ew O rl ea ns L et te r R ef T

D at ed

5-

JA

N -2

TAI 1208 USACE

LOAD

FACTOR

KW

LOAD

FACTOR

KW

LOAD

KW

Diesel Tank Heater 1 480V 18.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 16.20 0.00 0.00 0.00 0.00

Air Conditioner 1 208V 3.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00 0.70 2.10 0.00 0.00

Cab Heaters 1 208V 2.25 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03 0.00 0.00 0.90 2.03

Cab Defrosters 1 208V 2.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 1.13 0.00 0.00 0.00 0.00

Camera System 1 120V 0.29 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 0.14 0.50 0.14 0.00 0.00 0.00 0.00

Cab Light 1 120V 0.03 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02 0.60 0.02

Gantry Lights 1 120V 0.31 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19 0.60 0.19

Eng. H. Lights 1 120V 0.18 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11 0.60 0.11

Cab Enclosure Light 1 120V 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01

Gps System 1 120V 0.21 0.90 0.19 0.90 0.19 0.90 0.19 0.90 0.19 0.90 0.19 0.90 0.19 0.90 0.19 0.90 0.19

24VDC Power Supply 1 208V 0.96 0.80 0.77 0.80 0.77 0.80 0.77 0.80 0.77 0.90 0.86 0.90 0.86 0.80 0.77 0.80 0.77

12VDC Power Supply 1 120V 0.29 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23 0.80 0.23

Boom Lights 1 208V 0.67 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40 0.60 0.40

Cab GFCI Receptacle 2 120V 1.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 1.92 0.50 1.92 0.00 0.00 0.00 0.00

Hydraulic Oil Heaters 1 208V 4.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00 0.00 0.00 0.50 2.00

Water Jacket Heater 1 208V 3.00 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50 0.00 0.00 0.50 1.50

Engine House Heater 2 208V 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10 0.00 0.00 0.50 3.10

Engine Oil Heater 1 208V 0.30 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08 0.00 0.00 0.25 0.08

Battery Charger 1 208V 1.70 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68 0.40 0.68

Electrical Cabinet Light 1 120V 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01 0.60 0.01

Engine House GFCI Receptacle 1 120V 1.92 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.90 1.73 0.90 1.73 0.00 0.00 0.00 0.00

Slip Ring Heater 1 120V 0.06 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05 0.00 0.00 0.90 0.05

GFD Test 1 120V 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19 1.00 0.19

Total Crane Slip Ring Load 4.89 11.54 4.89 11.54 8.77 32.75 4.89 11.54

Welder 1 240VAC, 3Phase 18.00 0.20 3.60 0.20 3.60 0.10 1.80 0.10 1.80 0.20 3.60 0.20 3.60 0.10 1.80 0.10 1.80

Plasma Cutter (Center) 1 240VAC, 3Phase 3.00 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30

Welding Invertor 1 240VAC, 3Phase 2.25 0.10 0.23 0.10 0.23 0.00 0.00 0.00 0.00 0.10 0.23 0.10 0.23 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 1 ‐ 75Amps 1 240VAC, 3Phase 13.20 0.20 2.64 0.20 2.64 0.10 1.32 0.10 1.32 0.20 2.64 0.20 2.64 0.10 1.32 0.10 1.32

240VAC Deck Receptacle # 2 ‐ 75Amps 1 240VAC, 3Phase 13.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 3 ‐ 75 Amps 1 240VAC, 3Phase 13.20 0.20 2.64 0.20 2.64 0.00 0.00 0.00 0.00 0.20 2.64 0.20 2.64 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 4 ‐ 75 Amps 1 240VAC, 3Phase 13.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 5 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.20 0.88 0.20 0.88 0.10 0.44 0.10 0.44 0.20 0.88 0.20 0.88 0.13 0.55 0.13 0.55

240VAC Deck Receptacle # 6 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 7 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.20 0.88 0.20 0.88 0.00 0.00 0.00 0.00 0.20 0.88 0.20 0.88 0.00 0.00 0.00 0.00

240VAC Deck Receptacle # 8 ‐ 25 Amps 1 240VAC, 3Phase 4.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

11.17 11.17 3.86 3.86 11.17 11.17 3.97 3.97

Crane Slip Ring Loads

OPERATING CONDITION - 04

SUMMER WINTER

ITEM NO.

MDC 2989 Floating Crane - Electrical Plant Load Analysis- Rev 0

OPERATING CONDITIONS

OPERATING CONDITION - 01 OPERATING CONDITION - 02

OPERATING CONDITION - 03

VOLTAGE

LOAD DESCRIPTION QTY

CONNECTED

PER ITEM

Loads on 480 to 240VAC Transformer

Total Load on 480 to 240 VAC Tx - This load is reflected as a load factor on the 480 to 240VAC Tx ew O rle ans L ette r R ef T

1819621 D ate d 1 5-J

AN-2

KW

LOAD

FACTOR

KW

LOAD

OPERATING CONDITION - 04

ITEM NO.

MDC 2989 Floating Crane - Electrical Plant Load Analysis- Rev 0

OPERATING CONDITIONS

OPERATING CONDITION - 01 OPERATING CONDITION - 02

OPERATING CONDITION - 03

VOLTAGE

LOAD DESCRIPTION QTY

CONNECTED

PER ITEM

Fuel Transfer Pump (2hp/1.5 KW) 1 120V, 1 Phase 1.50 0.10 0.15 0.10 0.15 0.10 0.15 0.10 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Auxiliary Bilge Pump, Portable (2 HP/1.5kw) 1 120V, 1 Phase 1.50 0.10 0.15 0.10 0.15 0.10 0.15 0.10 0.15 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Ship Receptacle circuit #1 2 120V, 1 Phase 1.80 0.10 0.36 0.10 0.36 0.30 1.08 0.30 1.08 0.10 0.36 0.10 0.36 0.30 1.08 0.30 1.08

Ship Receptacle circuit #2

Ship Receptacle circuit #3

Ship Receptacle circuit #4

Flood Lights (LED) 14 120V, 1 Phase 0.30 0.60 2.52 0.60 2.52 0.60 2.52 0.60 2.52 0.60 2.52 0.60 2.52 0.60 2.52 0.60 2.52

Module Bucket 1 120V, 1 Phase 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.75 1.50 0.75 1.50 0.00 0.00 0.00 0.00

Switchboard Heater 1 120V, 1 Phase 0.96 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86 0.00 0.00 0.90 0.86

Spud Winch Heater 4 120V, 1 Phase 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.50 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 1.00

Deck Winch Heater 2 120V, 1 Phase 0.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Genset Engine Block Heater 2 120V, 1 Phase 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 0.50 0.00 0.00 0.25 0.50 0.00 0.00 0.25 0.50

Standalone Genset Engine Block Heater 1 120V, 1 Phase 1.00 0.00 0.00 0.25 0.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

DC Battery Charger 1 120V, 1 Phase 1.44 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58 0.40 0.58

Genset Battery Charger 1 120V, 1 Phase 1.08 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43 0.40 0.43

5.3 6.4 8.1 11.5 6.5 7.8 7.8 10.2

48 Spud Winch #1 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28

49 Spud Winch #2 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.90 40.28 0.90 40.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

50 Spud Winch #3 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

51 Spud Winch #4 1 480V, 3 PHASE 44.8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

52 Deck Winch Port ‐ 40 ton 1 480V, 3 PHASE 5.6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

53 Deck Winch Stbd ‐ 40 ton 1 480V, 3 PHASE 5.6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

54 480V to 240VAC ‐ 45 KVA Transformer 1 480V, 3 PHASE 36.00 0.31 11.17 0.31 11.17 0.11 3.86 0.11 3.86 0.31 11.17 0.31 11.17 0.11 3.97 0.11 3.97

55 480V to 208/120VAC ‐ 45 KVA Transformer 1 480V, 3 PHASE 36.00 0.15 5.27 0.18 6.38 0.23 8.15 0.32 11.51 0.18 6.47 0.22 7.83 0.22 7.85 0.28 10.21

56 Crane Slip Ring Service Load per Seatrax (200A @ 480V) 1 480V, 3 PHASE 56.2 0.09 4.89 0.21 11.54 0.09 4.89 0.21 11.54 0.16 8.77 0.58 32.75 0.09 4.89 0.21 11.54

TOTAL 480VAC LOAD 21.3 29.1 97.5 107.5 26.4 51.8 57.0 66.0

ITEM NO. Power Source eKW

1 GENSET # 1 75 0 0.00 0 0.00 1 75.00 1 75.00 0 0.00 1 75.00 1 75.00 1 75.00

2 GENSET # 2 75 0 0.00 0 0.00 1 75.00 1 75.00 0 0.00 0 0.00 0 0.00 0 0.00

3 Shore Power 66.5 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00

4 Standalone Generator 35 1 35.00 1 35.00 0 0.00 0 0.00 1 35.00 0 0.00 0 0.00 0 0.00

ELECTRIC LOAD PER GENSET % 60.91% 83.11% 64.97% 71.65% 75.45% 69.00% 75.98% 88.01%

NO OF GENSET ON LOAD - 1 1 2 2 1 1 1 1

208/240/120V LOADS

480V MAIN SWITCHBOARD

Operating Condition 2: Lifting two spuds simultaneously, barge service loads and crane general service loads except crane diesel heater loads

Operating Condition 3: Crane general service, crane heating and barge service loads

Operating Condition 4: Lifting one spud, barge service loads and crane general service loads except crane diesel heater loads

Operating Condition 1: Barge service loads and crane general service loads except crane diesel heater loads

LEGEND:

TOTAL 208/240/120VAC LOAD - This load is reflected as a load factor on the 480 to 208/120VAC Tx

OPERATING CONDITION - 01 SUMMER OPERATING CONDITION - 02 SUMMER OPERATING CONDITION - 03 SUMMER OPERATING CONDITION - 04 SUMMER ew O rle ans L ette r R ef T

1819621 D ate d 1 5-J

AN-2

ew O rle ans L ette r R ef T

1819619 D ate d 2 4-J

AN

ew O rle ans L ette r R ef T

1819619 D ate d 2 4-J

AN

ew O rle ans L ette r R ef T

1819619 D ate d 2 4-J

AN

ew O rle ans L ette r R ef T

1819620 D ate d 1 5-J

AN

S ee

A B S N ew O rle an s Le tte r R ef T

D at ed

4-

JA

N -2

Load Volts Connected Circuit No. Wire AWG Amps Phase Length

Circular Mil Area of the Conductor

Voltage Drop

From Individual

Sub-Panels

Voltage Drop

From

Switchboard

Voltage Drop %

From Shore

Power

From Generators

Units [V] - I [A] L [ft] Circular Mils [V] [%] [%] [%] [%]

Generator Set 1 to Switchboard 480 Gen 1 2/0 113 3 15 133000 0.3 0.1% N/A N/A 0.1%

Generator Set 2 to Switchboard 480 Gen 2 2/0 113 3 15 133000 0.3 0.1% N/A N/A 0.1%

Stand-By Generator to Switchboard 480 Gen 3 4 53 3 10 41700 0.3 0.1% N/A N/A 0.1%

Shore Power Disconnect to Shore Power

Interlock 480 SP-1 2 100 3 100 66400 3.4 0.7% N/A 0.7% N/A

Shore Power Interlock to Shore Power Circuit

Breaker 480 SP-2 2 100 3 15 66400 0.5 0.1% N/A 0.8% N/A

Shore Power Circuit Breaker to Shore Power

Isolation Transformer 480 SP-3 2 100 3 15 66400 0.5 0.1% N/A 0.9% N/A

Shore Power Isolation Transformer to

Switchboard 480 SP-4 2 100 3 15 66400 0.5 0.1% N/A 1.0% N/A

Switchboard to Spud Winch #1 VFD 480 SB-1-1 4 67 3 100 41700 3.6 0.8% 0.8% 1.8% 0.8%

Spud Winch #1 VFD to Spud Winch #1 480 SB-1-2 4 67 3 20 41700 0.7 0.2% 0.2% 1.9% 0.2%

Switchboard to Spud Winch #2 VFD 480 SB-2-1 4 67 3 100 41700 3.6 0.8% 0.8% 1.8% 0.8%

Spud Winch #2 VFD to Spud Winch #2 480 SB-2-2 4 67 3 20 41700 0.7 0.2% 0.2% 1.9% 0.2%

Switchboard to Spud Winch #3 VFD 480 SB-3-1 4 67 3 45 41700 1.6 0.3% 0.3% 1.4% 0.4%

Spud Winch #3 VFD to Spud Winch #3 480 SB-3-2 4 67 3 20 41700 0.7 0.2% 0.2% 1.5% 0.2%

Switchboard to Spud Winch #4 VFD 480 SB-4-1 4 67 3 45 41700 1.6 0.3% 0.3% 1.4% 0.4%

Spud Winch #4 VFD to Spud Winch #4 480 SB-4-2 4 67 3 20 41700 0.7 0.2% 0.2% 1.5% 0.2%

Switchboard to Deck Winch Port 480 SB-5 14 12 3 80 4110 5.1 1.1% 1.1% 2.1% 1.1%

Switchboard to Deck Winch Stbd 480 SB-6 14 12 3 80 4110 5.1 1.1% 1.1% 2.1% 1.1%

Switchboard to Crane Slip Ring Service Load

(Heating & Lighting) 480 SB-8 2 85 3 57 66400 1.6 0.3% 0.3% 1.4% 0.4%

Switchboard to 45KVA Transformer 1 480 SB-9-1 6 54 3 20 26300 0.9 0.2% 0.2% 1.2% 0.3%

Switchboard to 45KVA Transformer 2 480 SB-10-1 6 54 3 20 26300 0.9 0.2% 0.2% 1.2% 0.3%

45KVA Transformer 1 to 45KVA Transformer

1 Disconnect 208 SB-9-2 1/0 125 3 10 106000 0.3 0.1% 0.3% 1.1% 0.2%

45KVA Transformer 2 to 45KVA Transformer

2 Disconnect 208 SB-10-2 1/0 108 3 10 106000 0.2 0.1% 0.3% 1.1% 0.2%

45KVA Transformer 1 Disconnect to

Distribution Panel P201 208 SB-9-3 1/0 125 3 20 106000 0.5 0.3% 0.6% 1.5% 0.5%

45KVA Transformer 2 Disconnect to

Distribution Panel P202 240 SB-10-3 1/0 108 3 20 106000 0.5 0.2% 0.5% 1.4% 0.4%

DP P201 to Fuel Transfer Pump 208 P201-1 14 16 3 24 4110 2.0 1.0% 1.6% 2.4% 1.4%

DP P201 to Portable Bilge Pump 120 P201-3 10 16 3 70 10400 2.3 2.0% 2.5% 3.4% 2.4%

DP P201 to Deck Winch Heater 1 & 2 120 P201-4 12 10 1 61 6530 2.5 2.1% 2.7% 3.5% 2.5%

DP P201 to Genset Battery Charger 120 P201-5 14 11 1 15 4110 1.1 0.9% 1.5% 2.3% 1.3%

DP P201 to Spud Winch Heater # 1& 2 120 P201-6 6 21 1 100 26300 2.0 1.7% 2.3% 3.1% 2.1%

DP P201 to DC Battery Charger 120 P201-7 10 15 1 57 10400 2.1 1.8% 2.3% 3.2% 2.2%

MDC 2989 FLOATING CRANE - VOLTAGE DROP CALCULATIONS - Rev 0 ew O rle ans Lette r R ef T 1819619 D ated 24-JAN-2

Load Volts Connected Circuit No. Wire AWG Amps Phase Length

Circular Mil Area of the Conductor

From Individual

Sub-Panels

Voltage Drop

From

Switchboard

From Shore

Power

From Generators

Units [V] - I [A] L [ft] Circular Mils [V] [%] [%] [%] [%]

MDC 2989 FLOATING CRANE - VOLTAGE DROP CALCULATIONS - Rev 0

DP P201 to Spud Winch Heater # 3 & 4 120 P201-8 6 21 1 100 26300 2.0 1.7% 2.3% 3.1% 2.1%

DP P201 to Ship Receptacle # 3 120 P201-10 6 19 2 150 26300 2.8 2.3% 2.9% 3.7% 2.7%

DP P201 to Flood Lighting Circuit #1 120 P201-11 8 9 1 125 16500 1.8 1.5% 2.1% 2.9% 2.0%

DP P201 to Ship Receptacle # 4 120 P201-12 6 19 2 150 26300 2.8 2.3% 2.9% 3.7% 2.7%

DP P201 to Module Bucket 120 P201-13 8 21 1 80 16500 2.6 2.2% 2.7% 3.6% 2.6%

DP P201 to Flood Lighting Circuit #2 120 P201-14 8 9 1 125 16500 1.8 1.5% 2.1% 2.9% 2.0%

DP P201 to Genset Block Heater 120 P201-15 12 21 1 15 6530 1.2 1.0% 1.6% 2.4% 1.5%

DP P201 to Ship Receptacle # 1 120 P201-16 10 19 2 50 10400 2.3 1.9% 2.5% 3.3% 2.4%

DP P201 to Standby Genset Block Heater 120 P201-17 14 10 1 15 4110 1.0 0.8% 1.4% 2.2% 1.3%

DP P201 to Switchboard Heater 120 P201-18 14 10 1 5 4110 0.3 0.3% 0.8% 1.7% 0.7%

DP P201 to Ship Receptacle # 2 120 P201-20 10 19 2 50 10400 2.3 1.9% 2.5% 3.3% 2.4%

DP P201 to Flood Lighting Circuit #3 120 P201-22 8 13 1 125 16500 2.4 2.0% 2.6% 3.4% 2.5%

DP P201 to Flood Lighting Circuit #4 120 P201-24 8 13 1 125 16500 2.4 2.0% 2.6% 3.4% 2.5%

DP P202 to Welder 240 P202-1 4 54 3 100 41700 2.9 1.2% 1.7% 2.6% 1.6%

DP P202 to Plasma Cutter 240 P202-2 10 9 3 115 10400 2.2 0.9% 1.4% 2.3% 1.4%

DP P202 to Welding Invertor 240 P202-3 10 7 3 80 10400 1.2 0.5% 1.0% 1.9% 0.9%

DP P202 to Deck Receptacles 13.2kw #1 240 P202-4 6 40 3 115 26300 3.9 1.6% 2.1% 3.0% 2.1%

DP P202 to Deck Receptacles 13.2kw #2 240 P202-5 6 40 3 115 26300 3.9 1.6% 2.1% 3.0% 2.1%

DP P202 to Deck Receptacles 13.2kw #3 240 P202-6 6 40 3 50 26300 1.7 0.7% 1.2% 2.1% 1.1%

DP P202 to Deck Receptacles 13.2kw #4 240 P202-7 6 40 3 50 26300 1.7 0.7% 1.2% 2.1% 1.1%

DP P202 to Deck Receptacles 4.4 kw #5 240 P202-8 12 13 3 65 6530 2.9 1.2% 1.7% 2.6% 1.7%

DP P202 to Deck Receptacles 4.4 kw #6 240 P202-9 12 13 3 115 6530 5.2 2.2% 2.7% 3.6% 2.6%

DP P202 to Deck Receptacles 4.4 kw #7 240 P202-10 12 13 3 65 6530 2.9 1.2% 1.7% 2.6% 1.7%

DP P202 to Deck Receptacles 4.4 kw #8 240 P202-11 12 13 3 115 6530 5.2 2.2% 2.7% 3.6% 2.6%

Single Phase: (2xKxLxI)/CM

Three Phase: (1.732xKxLxI)/CM

Note: K value (12.9 ohms-cmil/ft) is considered for copper cables

Voltage Drop Equations ew O rle ans Lette r R ef T 1819619 D ated 24-JAN-2

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Task – T1819619 TAI Crane Barge – 160’ Crane Barge ABS Pre-Contract Design Review prior to

Request for Class Flag: United States of America

Attention: Ms. Krishna Karri, Technology Associates, Inc. (WCN: 426181)

The documents shown in the attached list are reviewed in accordance with the applicable requirements of the following:

· ABS Rules for Building and Classing Steel Barges, 2018, as amended

· ABS Rules for Building and Classing Steel Vessels Under 90M (295 feet) in

Length, 2018, as amended, as applicable

Please note our review is based on the following conditions / scope:

1 . We recognize that the submitted drawings are intended for basic design only. As such, the subject review has been focused on verifying compliance reflective of the detail shown in the submitted drawing and identifying noncompliance items with the applicable Rules and Code(s) listed above. Review for full compliance with the Rules and Code(s), such as complete Bill of Materials for piping, valves and specialty items and certificates/cut sheets for system components is to be carried out during the review of the detail design.

2. Once the vessel is contracted for construction, the drawings are to be resubmitted to ABS for detailed review for Classification.

3. It should be noted that our review at this time in no way precludes any future amendments which may be deemed necessary by submission and review of detailed drawings for Classification.

4. Rule required remote emergency stops not shown to be part of vessel detailed review.

Additionally, we have received your declaration stating that the materials used in the system indicated in the submittal are free from asbestos.

For any clarifications, contact Mr. Richard Barbour at (504) 262-5229 or

(RBarbour@eagle.org)

Very truly yours, Roy H. Bleiberg Director of Engineering

Electronically Signed by: Richard H. Barbour III

Reference T1819619, dated 24-JAN-2019.

mailto:RBarbour@eagle.org

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Documents List

Drawing No.

Rev.

No.

Title Status

850-B720-01 1 AC One Line Reviewed 850-B725-01 0 AC Voltage Drop

Calculations Reviewed

Electronic copies of the documents, appropriately stamped, are available in the ABS My

Eagle Portal through Engineering Manager.

Reference T1819619, dated 24-JAN-2019.

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Task – T1819620 TAI Crane Barge – 160’ Crane Barge ABS Pre-Contract Design Review prior to

Request for Class Flag: United States of America

Attention: Ms. Krishna Karri, Technology Associates, Inc. (WCN: 426181)

The documents shown in the attached list are reviewed in accordance with the applicable requirements of the following:

1 . We recognize that the submitted drawings are intended for basic design only. As such, the subject review has been focused on verifying compliance reflective of the detail shown in the submitted drawing and identifying noncompliance items with the applicable Rules and Code(s) listed above. Review for full compliance with the Rules and Code(s), such as complete Bill of Materials for piping, valves and specialty items and certificates/cut sheets for system components is to be carried out during the review of the detail design.

2. Once the vessel is contracted for construction, the drawings are to be resubmitted to ABS for detailed review for Classification.

3. It should be noted that our review at this time in no way precludes any future amendments which may be deemed necessary by submission and review of detailed drawings for Classification.

Additionally, we have received your declaration stating that the materials used in the system indicated in the submittal are free from asbestos.

For any clarifications, contact Mr. Richard Barbour at (504) 262-5229 or

(RBarbour@eagle.org)

Very truly yours, Roy H. Bleiberg

Reference T1819620, dated 15-JAN-2019.

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Documents List

Drawing No.

Rev.

No.

Title Status

850-B730-01 0 Lighting Arrangements Reviewed 850-B730-02 0 Receptacle Plan Reviewed Electronic copies of the documents, appropriately stamped, are available in the ABS My

Eagle Portal through Engineering Manager.

Reference T1819620, dated 15-JAN-2019.

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Task – T1819621 TAI Crane Barge – 160’ Crane Barge ABS Pre-Contract Design Review prior to

Request for Class Flag: United States of America

Attention: Ms. Krishna Karri, Technology Associates, Inc. (WCN: 426181)

The documents shown in the attached list are reviewed in accordance with the applicable requirements of the following:

1 . We recognize that the submitted drawing is intended for basic design only. As such, the subject review has been focused on verifying compliance reflective of the detail shown in the submitted drawing and identifying noncompliance items with the applicable Rules and Code(s) listed above. Review for full compliance with the Rules and Code(s), such as complete Bill of Materials for piping, valves and specialty items and certificates/cut sheets for system components is to be carried out during the review of the detail design.

2. Once the vessel is contracted for construction, the drawing is to be resubmitted to

ABS for detailed review for Classification.

3. It should be noted that our review at this time in no way precludes any future amendments which may be deemed necessary by submission and review of detailed drawings for Classification.

Additionally, we have received your declaration stating that the materials used in the system indicated in the submittal are free from asbestos.

For any clarifications, contact Mr. Richard Barbour at (504) 262-5229 or (RBarbour@eagle.org)

Very truly yours, Roy H. Bleiberg

Reference T1819621, dated 15-JAN-2019.

800 West Commerce Road, Suite 400, Harahan, LA 70123 USA

Documents List

Drawing No.

Rev.

No.

Title Status

850-B710-01 0 AC Load Analysis Reviewed Electronic copies of the documents, appropriately stamped, are available in the ABS My

Eagle Portal through Engineering Manager.

Reference T1819621, dated 15-JAN-2019.

Review Letter_110799829
TAI 1208_850-B730-01_Rev 0_LIGHTING ARRANGEMENTS_12-31-18_110670325
TAI 1208_850-B730-03_REV 0_NAVIGATION LIGHTING ARRANGEMENTS_12-27-18_110799832
TAI_1208_850-B710-01_REV 0_AC LOAD ANALYSIS_12-31-18_110673967
TAI_1208_850-B720-01_REV 1_AC ONE LINE_1-21-19_110803991_110818998
TAI_1208_850-B730-02_Rev 0_RECEPTACLE PLAN_12-31-18_110672326
TAI-1208_850-B725-01_Rev 0_AC Voltage Drop Calculations_1-2-19_110823089
USACOE Crane Barge T1819619 One Line and VD calcs ltr_110819000
USACOE Crane Barge T1819620 Ltg ltr_110661660
USACOE Crane Barge T1819621 Load Anal ltr_110673968