AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
PROJECT TITLE: THE DALLES ARC FLASH HAZARD REDUCTION
SEE CONTINUATION PAGES
1. CONTRACT ID CODE PAGE OF PAGES
1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 21-Sep-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9127N-17-R-0003
X 9B. DATED (SEE ITEM 11)
10-Aug-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
21-Sep-2017
CODE
USACE PORTLAND DISTRICT
333 SW 1ST AVE
PORTLAND OR 97204-3440
W9127N 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9127N-17-R-0003
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION 00010 - SOLICITATION CONTRACT FORM
The required response date/time has changed from 25-Sep-2017 04:00 PM to 28-Sep-2017 04:00 PM.
The following have been added by full text:
AMENDMENT 0004
1. This Amendment is issued to update the plans and specifications.
2. Technical Specification Section 27 21 10.00 26 has been added.
3. Attachment A1, Submittal Register has been updated in its entirety.
4. Drawings E-801 and E-802 have been updated.
5. The proposal due date is extended from 25 September 2017 to 28 September 2017 at 4:00 PM local time.
6. All other terms and conditions remain unchanged.
(End of Summary of Changes)
The Dalles Arc Flash Hazard Reduction Project
PROJECT TABLE OF CONTENTS
DIVISION 01 - GENERAL REQUIREMENTS
01 10 00.00 25 CONTRACT ADMINISTRATION DATA
01 10 10.00 25 CONTRACTOR'S OPERATIONS AND REQUIREMENTS
01 11 00.00 25 SUMMARY OF WORK
01 22 00.00 25 MEASUREMENT AND PAYMENT
01 32 01.00 25 PROJECT SCHEDULE
01 33 00 SUBMITTAL PROCEDURES
01 35 26.00 25 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 25 QUALITY CONTROL
01 45 00.15 25 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM)
01 57 20.00 25 ENVIRONMENTAL PROTECTION
01 78 23.00 25 OPERATION AND MAINTENANCE DATA
01 78 39.00 25 PROJECT RECORD DOCUMENTS
DIVISION 02 - EXISTING CONDITIONS
02 82 14.00 25 ASBESTOS ABATEMENT WORK
02 83 13.00 20 LEAD IN CONSTRUCTION
DIVISION 03 - CONCRETE
03 60 00.00 26 CONCRETE DEMOLITION, REPAIR OF CONCRETE SURFACES, AND
EQUIPMENT FOUNDATIONS
DIVISION 13 - SPECIAL CONSTRUCTION
13 48 00.00 26 SEISMIC RESTRAINT FOR MECHANICAL AND ELECTRICAL EQUIPMENT
DIVISION 26 - ELECTRICAL
26 05 00.00 26 ELECTRICAL EQUIPMENT AND WORK
26 05 19.00 26 INSULATED WIRE AND CABLE
26 05 26.00 26 GROUNDING
26 08 01.00 26 FIELD TESTING
26 13 13.00 26 METAL CLAD SWITCHGEAR
26 28 00.00 26 SWITCHBOARDS
DIVISION 27 - COMMUNICATIONS
27 21 10.00 26 FIBER OPTIC DATA TRANSMISSION SYSTEM
DIVISION 33 - UTILITIES
33 72 33.14 26 POWER SYSTEM RELAY PROTECTION AND METERING
33 75 10.00 26 MOTOR OPERATORS FOR HIGH VOLTAGE GROUND DISCONNECT SWITCH
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 1
SECTION TABLE OF CONTENTS
DIVISION 27 - COMMUNICATIONS
SECTION 27 21 10.00 26
FIBER OPTIC DATA TRANSMISSION SYSTEM
PART 1 GENERAL
1.1 GENERAL INFORMATION
1.1.1 General
1.2 REFERENCES
1.3 SUBMITTALS
1.4 QUALIFICATIONS
1.5 MANUFACTURER'S CATALOG DATA
1.6 MATERIAL AND EQUIPMENT LIST
1.7 DELIVERY, STORAGE, AND HANDLING
PART 2 PRODUCTS
2.1 GENERAL
2.2 FIBER OPTIC CABLE
2.2.1 General
2.2.2 Single-mode Fiber Optic Cable
2.2.3 Cable Construction
2.3 PATCH PANELS
2.3.1 General
PART 3 EXECUTION
3.1 FIBER OPTIC CABLE INSTALLATION
3.1.1 General
3.1.2 Installation Procedures
3.1.3 Cable Installation Plan
3.1.4 Service Loops
3.1.5 Splices
3.1.6 Identification and Labeling
3.2 FIBER TEST
3.2.1 General
3.2.2 Fiber Test Plan
3.2.3 Fiber Field Test
3.2.3.1 General
3.2.3.2 Optical Time Domain Reflectometer Tests
3.2.3.3 Power Attenuation Test
3.2.4 Fiber Test Report
3.3 OPERATIONS AND MAINTENANCE MANUAL
3.4 ACCEPTANCE
-- End of Section Table of Contents --
SECTION 27 21 10.00 26 Page 1
ADDED BY AMENDMENT AMD# 0004
SECTION 27 21 10.00 26
FIBER OPTIC DATA TRANSMISSION SYSTEM
PART 1 GENERAL
1.1 GENERAL INFORMATION
1.1.1 General
This Section covers fiber optic cable installation and testing requirements.
1.2 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the ASIC designation only.
ELECTRONIC INDUSTRIES ALLIANCE (EIA)
ANSI/TIA-455-80C (2003) FOTP-80 - IEC 60793-1-144 Optical fibres Part 1-44: Measurement Methods and Test Procedures - Cut-off Wavelength
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2014; AMD 1 2013; Errata 1 2013; AMD 2 2013; Errata 2 2013; AMD 3 2014; Errata 3-4 2014; AMD 4-6 2014) National Electrical Code
TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)
TIA-455-104 (2016b) Standard for FOTP-104 Fiber Optic Cable Cyclic Flexing Test
TIA-455-13 (1996a; R 2012) FOTP-13 Visual and Mechanical Inspection of Fiber Optic Components, Devices, and Assemblies
TIA-455-177 (2003b) FOTP-177 IEC-60793-1-43:
Measurement Methods and Test Procedures - Numerical Aperture
TIA-455-78-B (2002) FOTP-78 Optical Fibres - Part 1-40: Measurement Methods and Test Procedures - Attenuation
TIA-455-91 (1986; R 1996) FOTP-91 Fiber Optic Cable Twist-Bend Test
TIA-606 (2012b; Add 1 2015) Administration Standard for the Telecommunications Infrastructure
TIA/EIA-455-171 (2001a) FOTP-171 - Attenuation by Substitution Measurement for Short-Length
SECTION 27 21 10.00 26 Page 2
Multimode Graded-Index and Single-Mode Optical Fiber Cable Assemblies
TIA/EIA-455-25 (2016d) FOTP-25 Impact Testing of Optical Fiber Cables
TIA/EIA-455-41 (1993a; R 2013) FOTP-41 Compressive Loading Resistance of Fiber Optic Cables
TIA/EIA-455-88 (2001) FOTP-88 Fiber Optic Cable Bend Test
UNDERWRITERS LABORATORIES (UL)
UL 1666 (2007; Reprint Jun 2012) Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts
1.3 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following must be submitted in accordance with Section 01 33 00, SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Cable Installation Plan; G, HDC Cable Installation plan must be submitted at least 30 calendar days prior to installation.
Fiber Test Plan; G, HDC Fiber test plan must be submitted at least 14 calendar days prior to the start of testing.
SD-03 Product Data
Manufacturer's Catalog Data; G, HDC Manufacturer catalog data must be submitted at least 30 calendar days prior to installation.
Material and Equipment List; G, HDC Material and Equipment List must be submitted 30 day after the award of the Contract.
SD-06 Test Reports
Fiber Test Report; G, HDC The final performance verification test report must be delivered 15 days after completion of testing.
SD-07 Certificates
Qualifications; G
SD-08 Manufacturer's Instructions
Installation Procedures; G, HDC
SECTION 27 21 10.00 26 Page 3
SD-10 Operation and Maintenance Data
Operations and Maintenance Manual; G, HDC The Operations and Maintenance Data must be delivered 30 days after installation and testing of all fiber optic equipment.
1.4 QUALIFICATIONS
a. Cable installation and termination work must be performed by construction personnel who have had at least 3-years experience in placing cables in conduit, cable trays, and underground duct systems.
b. Fiber optic cable splices, terminations, and testing must be made by journeymen cable splicers who have had a minimum of 1-year experience in splicing and terminating fiber optic cables. Personnel working pursuant to this Section, may at the Contracting Officer's option, be required to demonstrate technical competence by performing sample work and/or by displaying their state qualifications/certificates, at no additional cost to the Government.
1.5 MANUFACTURER'S CATALOG DATA
Manufacturer's Catalog Data composed of catalog cuts, brochures, circulars, specifications, product data, and printed information in sufficient detail and scope to verify compliance with the requirements of the Contract documents must be submitted prior to construction. Standard catalog data will not be acceptable unless irrelevant parts are marked out and relevant parts are clearly identified. Manufacturer's catalog data must be included in the required Operations and Maintenance Manual.
1.6 MATERIAL AND EQUIPMENT LIST
A complete itemized listing of equipment and materials proposed for incorporation into the work. Each entry must include an item number, the quantity of items proposed, and the name of the manufacturer complete with make and model of each item. Materials and equipment must conform to the respective publications and other requirements specified below and in the material and equipment list. Materials and equipment not listed below must be as specified elsewhere in this Section.
1.7 DELIVERY, STORAGE, AND HANDLING
The fiber optic cables must be furnished one length to a reel or coil.
Each length, and the outside of each reel or coil, must be plainly marked or tagged to indicate the cable length, cable type, number of fibers, and manufacturer's lot number and reel number. Reels shall remain the property of the Contractor.
PART 2 PRODUCTS
2.1 GENERAL
All fiber optic cable and associated equipment in this section must be provided by the Contractor and must conform to the requirements specified herein. Material and equipment characteristics, must be as indicated on the drawings, or as specified under the detailed requirements of these specifications for the particular construction or use, unless otherwise stated.
SECTION 27 21 10.00 26 Page 4
2.2 FIBER OPTIC CABLE
2.2.1 General
a. Optical fibers must be coated with a suitable material to preserve the intrinsic strength of the glass. The outside diameter of the glass-cladded fiber must be nominally 125 microns, and must be concentric with the fiber core. Optical fibers must meet TIA-455-78-B, and TIA-455-177.
b. Each fiber must be protected by a protective buffer tube. Cable and fiber protective covering must be free from holes, splits, blisters, and other imperfections. The covering must be flame retardant, moisture resistant, non-nutrient to fungus, ultraviolet light resistant as specified and nontoxic. Mechanical stress present in cable must not be transmitted to the optical fibers. Strength members must be non-metallic and must be an integral part of the cable construction.
The combined strength of all the strength members must be sufficient to support the stress of installation and to protect the cable in service. The cables must have a minimum storage temperature range of minus 40 to plus 158 degrees F. All cables furnished must meet the requirement of NFPA 70. Fire resistant characteristics of cables must conform to Article 770, Sections 49, 50, and 51. Cables must be from the same manufacturer, of the same cable type, and of the same size unless otherwise noted on the drawings or in this specification. Each fiber and protective coverings must be continuous with no factory splices. The manufacturer must certify fiber optic cable assemblies, including jacketing and fibers to have a minimum life of 30 years.
Ensure cables meet UL 1666. Certify fiber optic cable to meet the following: TIA-455-13, TIA/EIA-455-25, TIA/EIA-455-41, TIA-455-177, TIA-455-78-B, TIA/EIA-455-88, TIA-455-91, TIA-455-104, and
TIA/EIA-455-171.
c. Fiber optic cable must be rated for both indoor and outdoor applications. The cable must be rated to withstand temperatures of minus 40 to plus 185 degrees F. Equipment must be rated for continuous operation under the ambient environmental temperature, pressure, humidity, and vibration conditions specified or normally encountered for the installed location.
2.2.2 Single-mode Fiber Optic Cable
Use conductors that are single-mode, solid glass waveguides with a nominal core diameter of 8.3 microns. Ensure the fiber has transmission windows centered at 1310 and 1550 nanometer wavelengths with a numerical aperture minimum of 0.10. The attenuation for indoor/outdoor cable at 1310 and 1550 nanometers is 0.5 dB/Km or less. Certify the fibers to meet ANSI/TIA-455-80C. The number of fibers in each cable must be 12.
2.2.3 Cable Construction
Fiber optic cables installed must be low-smoke zero-halogen, loose tube, indoor/outdoor rated, single-mode (fiber category OS2), and have a flame-retardant jacket. Polyvinyl chloride (PVC) is not acceptable as a jacket material. Corning part number 012EUZ-T4101D2N_NAFTA_AEN or approved equal.
SECTION 27 21 10.00 26 Page 5
2.3 PATCH PANELS
2.3.1 General
Terminate fiber optic cables to existing patch panels in the warehouse building and the SCADA Rack in the 7th floor cable spreading room, station service bay. Ensure the integrity of the housing, terminations, splice storage, routing, radius limiting, cable fastening, storage, and cross-connection is maintained as a complete system.
PART 3 EXECUTION
3.1 FIBER OPTIC CABLE INSTALLATION
3.1.1 General
a. The Contractor must obtain from the manufacturer an installation manual or set of instructions which addresses such aspects as cable construction, insulation type, cable diameter, bending radius, cable temperature, lubricants, coefficient of friction, conduit cleaning, storage procedures, moisture seals, testing for and purging moisture, etc.
b. Cable installation and applications must meet the requirements of NFPA 70, Article 770, Sections 52 and 53. Cables not installed in conduits must be properly secured and neat in appearance, and if installed in plenums or other spaces used for environmental air, must comply with NFPA 70 requirements for this type of installation. The cable must not be forced around sharp corners, or tugged during installation. The cable must not be kinked or crushed and the maximum pulling tension and minimum bend radius of the cable must not be exceeded at any time during installation. The minimum bend radius must be as specified by the cable manufacturer, or 20 times the cable's outside diameter if not specified. If a cable lubricant is required, it must be compatible with the cable sheathing material. Pulling fixtures must be attached to the cable strength members. If the cable is pulled out of a junction or pull box the cable must be protected from dirt and moisture by laying the cable on a ground covering in a figure-eight configuration such that the cable's minimum bend radius is not exceeded. In such a case, the cable must be protected from vehicular and public traffic. The completed cable installation must provide protection from abrasion and sharp edges.
c. Cable must be installed strictly in accordance with the cable manufacturer's recommendations. Each circuit must be identified by means of a fiber, laminated plastic, or non-ferrous metal tags, or approved equal, in each cable vault, handhole, junction box, and each termination. Each tag must contain the following information: cable type, circuit number and cable destination.
d. Cable Inspection. The cable reel must be inspected for correct storage positions, signs of physical damage, and broken end seals. If end seal is broken, moisture must be removed from cable in accordance with the cable manufacturer's recommendations.
3.1.2 Installation Procedures
a. Where installation procedures or part of the installation procedures are required to be in accordance with manufacturer's instructions, SECTION 27 21 10.00 26 Page 6 submit printed copies of those instructions prior to installation.
Installation of the item must not proceed until manufacturer's instructions are received. Failure to submit manufacturer's instructions shall be cause for rejection of the equipment or material.
b. System components and appurtenances must be installed in accordance with the manufacturer's instructions and as shown. Interconnections, services, and adjustments required for a complete and operable data transmission system must be provided. The installation and testing of fiber optic cable and associated components must be accomplished by an installer who has documented training and experience in the installation and testing of this equipment. See the qualifications section within this specification for installer expertise requirements. Documentation must be furnished for review and approval prior to start of fiber optic equipment installations.
3.1.3 Cable Installation Plan
Contractor must prepare and submit a cable installation plan for all fiber optic cable pulls prior to construction. The Fiber Optic Cable installation plan must include at a minimum:
a. Site layout cable installation drawing with pulls identified in numeric order of expected pulling sequence and direction of cable pull.
b. List of cable installation equipment.
c. Lubricant manufacturer's application instructions.
d. Procedure for resealing cable ends to prevent moisture from entering cable.
e. Cable pulling tension calculations of all cable pulls.
f. Cable minimum bend radius and minimum diameter of pulling wheels used.
g. Maximum allowable pulling tension on the cable.
h. Maximum allowable pulling tension on pulling device.
3.1.4 Service Loops
Each fiber optic cable over 100ft. must have 15-foot service loops at each end unless indicated otherwise on the contract drawings. In addition, a minimum of 3 feet of contingency slack must be provided in each pull or junction box.
3.1.5 Splices
No splices will be permitted. Contractor shall be responsible for furnishing and installing new cable should any be damaged during installation or fail required testing.
3.1.6 Identification and Labeling
Identification tags or labels must be provided for each cable and/or fiber. Markers, tags and labels must use indelible ink or etching which
SECTION 27 21 10.00 26 Page 7 will not fade in sunlight, or in buried or underground applications.
Markers, tags, and labels must not become brittle or deteriorate for a period of 20 years. Label all termination blocks and panels with cable number or pair identifier for cables in accordance with TIA-606 and as specified. The labeling format must be as indicated on the drawings and a complete record must be provided to the Government with the final documentation. Each cable must be identified with type of signal being carried and termination points.
3.2 FIBER TEST
3.2.1 General
Fiber testing must be performed in the presence of the Government Quality Assurance Representative in accordance with the fiber test plan. The Contractor must notify the Government Quality Assurance Representative (GQAR) seven days prior to conducting tests. The Contractor must furnish all materials, labor, and equipment necessary to conduct tests. The Contractor must perform all tests including on-site tests and inspection recommended by the manufacturer unless specifically waived by the Government Quality Assurance Representative. The Contractor must maintain a written record of all tests that includes date, test performed, personnel involved, devices tested, serial number and name of test equipment, and test results for test reports and installation test reports. All test reports will be signed and dated by the Contractor.
3.2.2 Fiber Test Plan
Contractor must prepare and submit a fiber test plan that includes, at a minimum, a schedule of when tests will be performed relative to installation milestones, specific test procedure that will be used, a list of test equipment that will be used including manufacturer, model number, range, resolution accuracy, certificate of calibration and must conform to the specified requirements. The plan must be submitted prior to installation.
3.2.3 Fiber Field Test
3.2.3.1 General
The Contractor must verify the complete operation of the data transmission system prior to formal acceptance testing and recorded in the Fiber Test Report. These tests must be performed on each link and repeated from the opposite end of each link (bi-directional). Tests must be performed at both wavelengths (1310nm and 1550nm)unless indicated otherwise.
3.2.3.2 Optical Time Domain Reflectometer Tests
Optical time domain reflectometer (OTDR) tests must be performed using the FO test procedures of TIA-455-78-B. An optical time domain reflectometer test must be performed on all fibers of the FO cable on the reel prior to installation. The optical time domain reflectometer must be calibrated to show anomalies of 0.2 dB as minimum. Photographs of the traces must be furnished to the Government. An optical time domain reflectometer test must be performed on all fibers of the FO cable after it is installed. The optical time domain reflectometer must be calibrated to show anomalies of
0.2 dB as a minimum. If the optical time domain reflectometer test results show attenuation characteristics greater than those published by the cable manufacturer, the FO cable segment is unacceptable to the Government. The
SECTION 27 21 10.00 26 Page 8 unsatisfactory segments of cable must be replaced with a new segment of cable. The new segment of cable must then be tested to demonstrate acceptability. Photographs of the traces must be furnished to the Government for each link. The Contractor must use a "100 meter fiber launch cable" to eliminate the "dead zone" for the tests.
3.2.3.3 Power Attenuation Test
Power attenuation tests must be performed at the light wavelength of the transmitter to be used on the circuit being tested. The flux must be measured at the FO receiver end and must be compared to the flux injected at the transmitter end. There must be a jumper added at each end of the circuit under test so that end connector loss shall be validated.
Rotational optimization of the connectors will not be permitted. If the circuit loss exceeds the calculated circuit loss by more than 1 dB, the circuit is unsatisfactory and must be examined to determine the problem.
The Government must be notified of the problem and what procedures the Contractor proposes to eliminate the problem. The Contractor must prepare and submit a report documenting the results of the test. If the GQAR judges the losses to be excessive, the GQAR reserves the option to instruct the Contractor to re-terminate selected connectors and splices and/or to replace the cable as necessary.
3.2.4 Fiber Test Report
The Contractor's written records of testing must be submitted in the form of a formal shop test reports. Reports must identify each cable according to designations shown on the contract drawings. If no designation is shown, one will be provided by the Government. Test report must be submitted 15 days after completion of field testing.
3.3 OPERATIONS AND MAINTENANCE MANUAL
The following information must be included in the Operations and Maintenance Manual:
a. Manufacturer's operating and maintenance manuals for each item provided.
b. Manufacturer's catalog data for each item provided.
c. Recommended spare parts stocking list.
3.4 ACCEPTANCE
Final acceptance will depend upon the successful performance of the fiber optic cable and equipment under test. The final test reports must be reviewed and approved by the Contracting Officer.
-- End of Section --
SECTION 27 21 10.00 26 Page 9
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 1 OF 11 PAGES
01 10 10.00 25 SD-01 Preconstruction Submittals
1.4 GSchedule for Construction
1.9Line Outage Request
1.14 GAccess Agreements and Work
Areas
1.15 GSecurity Procedures
1.16.1 GPersonnel Risk Assessment
1.16.3.1 GQuarterly Security Awareness
Program
1.16.3.2 GAnnual NERC Mandated Cyber
Infrastructure Protection Training Program
1.17 GAnnual Antiterrorism and
Operations Security Training
1.20.2.2 GTemporary Electrical Wiring Plan
1.21.1 GContractor's Planned Equipment
Methods
1.21.2 GPlant and Equipment List
1.21.3 GLoading Diagram
1.23.1 GLifting Diagram
1.23.3 GLoading Plan for Cranes and
Heavy Equipment
1.25.1 GGas, Vapor, Fume, Dust, and
Mist Control Program
1.28 GDisposal Plan
01 22 00.00 25 SD-01 Preconstruction Submittals
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P H
C L A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
AUTH REMARKS
(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)
REPLACED IN ITS ENTIRETY
A1-1
AMD# 0004
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 2 OF 11 PAGES
01 22 00.00 25 1.5.1 GSchedule of Mobilization and Demobilization Costs
01 32 01.00 25 SD-01 Preconstruction Submittals
1.7.1 GECCCPreliminary Schedule
1.7.2 GECCCInitial Schedule
01 33 00 SD-01 Preconstruction Submittals
1.5 GSubmittal Register
SD-07 Certificates 1.10.2Authorized Shop Drawing
Approvers 01 35 26.00 25 SD-01 Preconstruction Submittals
1.6.1.3 GCrane Operators
1.7.3 GTraining Plan
1.7.4 GHazardous Energy Control Plan
and HEC Procedures Training Certification
1.8 GAccident Prevention Plan (APP)
1.9 GActivity Hazard Analysis (AHA)
3.5.2 GArc Flash Hazard (AFH) Program
1.7.6 GArc Flash Hazard (AFH) Training
Certification
1.8.2 GFatigue Management Plan (FMP)
SD-06 Test Reports 1.4Regulatory Citations, Violations, and Corrective Action
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-2
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 3 OF 11 PAGES
01 35 26.00 25 1.5Drug and Alcohol Use Prevention Program
1.14.2Accident or Mishap Reports SD-07 Certificates
1.10Confined Space Entry Permit 1.10Hot Work Permit
01 45 00.00 25 SD-01 Preconstruction Submittals
3.2 GContractor Quality Control Plan
3.4.4Construction Quality
Management for Contractors SD-06 Test Reports
3.9Daily CQC Report 01 57 20.00 25 SD-01 Preconstruction Submittals
1.10 GECDGEnvironmental Protection Plan
01 78 23.00 25 SD-01 Preconstruction Submittals
1.2 GO&M Manual Execution Plan
SD-10 Operation and Maintenance Data
1.3 GOperation and Maintenance
Manual
01 78 39.00 25 SD-01 Preconstruction Submittals
1.4 GRecord Drawings Execution Plan
1.5Working As-Built Drawings
SD-11 Closeout Submittals
1.7 GPreliminary Record Drawings
1.7.2.2 GFinal Working As-Built Drawings
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-3
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 4 OF 11 PAGES
01 78 39.00 25 1.8 GFinal Record Drawings 02 82 14.00 25 SD-01 Preconstruction Submittals
1.7 GECDGWritten Qualifications and
Organization Report
1.8 GECDGAsbestos Hazard Abatement
Plan
SD-06 Test Reports 1.14.1Daily Narrative Log 3.6Personnel and Area Air
Monitoring SD-07 Certificates
1.13Permits and Notifications 1.13Permits and Notifications 1.11Local Exhaust System 1.12Medical Surveillance
Requirements
3.9 GECDGWaste Shipment Record (WSR)
02 83 13.00 20 SD-01 Preconstruction Submittals
1.5.2.3 GOccupational and Environmental
Assessment Data Report
1.5.2.2 G ECDGLead Compliance Plan
1.5.1.1 G ECDGCompetent Person
1.5.1.2 G ECDGTraining Certification
1.5.2.8 G ECDGlead waste management plan
1.5.2.4 G ECDGMedical Examinations
SD-06 Test Reports
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-4
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 5 OF 11 PAGES
02 83 13.00 20 1.5.2.3 G ECDGsampling results
1.5.2.3 G ECDGOccupational and Environmental
Assessment Data Report SD-07 Certificates
1.5.1.3 G ECDGTesting laboratory
1.5.1.4 G ECDGThird party consultant
qualifications
3.5.1.1 G ECDGClearance Certification
03 60 00.00 26 SD-01 Preconstruction Submittals
3.4.1 G HDCConcrete Removal and Disposal
Plan
3.4.3 G HDCSaw Cutting Procedure
3.4.4 G HDCCore Drilling Procedure
3.4.8 G HDCConcrete Imaging Report
3.4.12 G HDCRepair Procedure of Concrete
Surfaces
2.5 G HDCFirestopping Materials
13 48 00.00 26 SD-02 Shop Drawings
1.5 G HDCDetail Drawings
1.6 G HDCDetail Drawings
SD-03 Product Data
3.4 G HDCConcrete Anchors
1.4.4 G HDCSeismic Equipment Certification
SD-05 Design Data
1.5 G HDCStructural Design Calculations for
Seismic Restraints
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-5
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 6 OF 11 PAGES
13 48 00.00 26 1.6 G HDCStructural Design Calculations for Seismic Restraints
SD-06 Test Reports
3.5.2.1 G HDCConcrete Anchor Test Reports
3.5.1 G HDCContractor Qualification Testing
26 05 00.00 26 SD-01 Preconstruction Submittals
3.1 G HDCEquipment Replacement and
Cutover Plan SD-02 Shop Drawings
1.6.1 G HDCDrawing Index
1.6.2 G HDCBill of Materials
1.6.3 G HDCInterconnecting Diagrams
1.6.4 G HDCConduit and Cable Schedule
1.6.5 G HDCConduit Routing Drawings
1.6.9 G HDCWiring Schematics
2.2.2 G HDCGround Conductors
2.5 G HDCFabricated Nameplates
2.6 G HDCMolded Case Circuit Breakers
1.6.6 G HDCAs-Built Drawings
SD-03 Product Data
2.1.1 G HDCConduit and Fittings
2.1.2 G HDCJunction Boxes
2.3 G HDCTerminal Blocks
2.4 G HDCBoxes, Cabinets, and Enclosures
2.13 G HDCControl Switches
26 05 19.00 26 SD-03 Product Data
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-6
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 7 OF 11 PAGES
26 05 19.00 26 2.1 G HDCInsulated Wire and Cable
2.4 G HDCSpecial Wire And Cable
SD-06 Test Reports
3.2.1 G HDCContinuity Tests
3.2.1 G HDCContinuity Tests
3.2.1 G HDCInsulation-Resistance Test
3.2.1 G HDCPhase-Rotation Tests
26 08 01.00 26 SD-05 Design Data
1.4.2 G HDCField Testing Plan
SD-06 Test Reports
1.5.2 G HDCField Test Reports
1.5.2 G HDCCircuit Functionality Test Report
1.5.2 G HDCContinuity Tests
26 13 13.00 26 SD-01 Preconstruction Submittals
3.5 G HDCQualifications of Field
Engineering Service Personnel
3.6 G HDCContractor Furnished Training of
Government Personnel
3.4 G HDCRemoval and Installation Plan
3.4 G HDCConstruction Progress Schedule
3.4 G HDCTemporary Power Plan for the
warehouse/security building SD-02 Shop Drawings
2.2.1.1 G HDCOutline Drawings
2.2.8.1 G HDCFoundation Details
2.2.1.2 G HDCAssembly and Detail Drawings
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-7
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 8 OF 11 PAGES
26 13 13.00 26 2.2.1 G HDCSchematic Diagrams and Connection Diagrams
2.2.1.3 G HDCSchematic Diagrams and
Connection Diagrams
1.4.4 G HDCAs-Built Drawings
SD-03 Product Data
2.1.1 G HDCList of Proposed Products
2.3 G HDCCircuit Breaker
2.7 G HDCInstrument Transformers
3.3.2.3 G HDCSwitchgear cubicles
2.2.6.4 G HDCInsulation
2.7.2.3 G HDCCurrent Transformer Calculations
2.7.1 G HDCSaturation Curves for Instrument
Transformers
2.9 G HDCAccessories
2.10 G HDCSpare Parts
SD-07 Certificates 3.3.1.1Certifications of Switchgear and
Breakers 3.1Certifications of Seismic
Requirements SD-09 Manufacturer’s Field Reports
3.3.1.2 G HDCDesign Test Reports
3.3.2.2 G HDCTest Record Forms
3.3.2.1 G HDCFactory Test Reports
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-8
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 9 OF 11 PAGES
26 13 13.00 26 3.3.3.1 G HDCfield test procedure
2.7.2.4 G HDCField Test Reports
3.3.3.1 G HDCField Test Reports
SD-10 Operation and Maintenance Data
1.4.2 G HDCSwitchgear
26 28 00.00 26 SD-02 Shop Drawings
2.1.5 G HDCArrangement Drawings
SD-03 Product Data
2.1.2.2 G HDCSwitchboard
2.2 G HDCMolded Case Circuit Breakers
2.1.4 G HDCBus Insulation and Barriers
SD-05 Design Data
3.3.4 G HDCField Acceptance Testing
3.3.4 G HDCField Test Reports
SD-07 Certificates
2.4 G HDCFactory Tests
SD-10 Operation and Maintenance Data
3.5 G HDCOperation and Maintenance
Manuals
27 21 10.00 26 SD-01 Preconstruction Submittals
3.1.3 G HDCCable Installation Plan
3.2.2 G HDCFiber Test Plan
SD-03 Product Data
1.5 G HDCManufacturer's Catalog Data
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-9
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 10 OF 11 PAGES
27 21 10.00 26 1.5 G HDCManufacturer's Catalog Data
1.6 G HDCMaterial and Equipment List
1.6 G HDCMaterial and Equipment List
SD-06 Test Reports
3.2.4 G HDCFiber Test Report
SD-07 Certificates
1.4 GQualifications
3.1.2 GQualifications
SD-08 Manufacturer’s Instructions
3.1.2 G HDCInstallation Procedures
SD-10 Operation and Maintenance Data
1.5 G HDCOperations and Maintenance
Manual
3.3 G HDCOperations and Maintenance
Manual
33 72 33.14 26 SD-03 Product Data
2.1 G HDCPROTECTIVE RELAYS
SD-05 Design Data
3.2 G HDCInstallation;
SD-06 Test Reports
3.3 G HDCField Testing;
3.3.3 G HDCManufacturer's Test Reports
SD-07 Certificates
1.6 G HDCDevices and Equipment
33 75 10.00 26 SD-02 Shop Drawings
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-10
SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 11 OF 11 PAGES
33 75 10.00 26 1.5.1 G HDCBill of Materials
1.5.2 G HDCOutline Drawings
1.5.2 G HDCMounting Details
1.5.2 G HDCSchematic Diagrams
1.5.2 G HDCManufacturer's Nameplate
SD-03 Product Data
2.1 G HDCground switch motor operator
2.2.5 G HDCInterlocking
SD-06 Test Reports
3.1.1 G HDCFactory Tests
SD-10 Operation and Maintenance Data
3.3 G HDCOperation and Maintenance
Manual
3.4Contractor-Furnished Training of Government Personnel
SUBMITTAL REGISTER
CONTRACT NO.
TITLE AND LOCATION CONTRACTOR
CONTRACTOR:
SCHEDULE DATES
CONTRACTOR
ACTION
APPROVING AUTHORITY
A C T I V I T Y
N O
T R A N S M I T T A L
N O
S P E C
S E C T
DESCRIPTION
ITEM SUBMITTED
P A R A G R A P
A S S I F I C A T I O N
G O V T
O R
A E
R E V W
R SUBMIT
APPROVAL
NEEDED
BY
MATERIAL
NEEDED
BY
A C T I O N
C O D E
DATE
OF
ACTION
DATE FWD
TO APPR
AUTH/
DATE RCD
FROM
CONTR
DATE FWD
TO OTHER
REVIEWER
DATE RCD
FROM OTH
REVIEWER
A C T I O N
C O D E
DATE
OF
ACTION
MAILED
TO
CONTR/
DATE RCD
FRM APPR
A1-11
NOTES:
CONDUIT
NUMBER SIZE LENGTH NO. CONDNUMBER SIZE
CABLE
INSUL. LGTH.(FEET) OPR. VOLT FUNCTION FROM
DISCRIPTIONS
TO ROUTING
REMARKS
SUA-c1-XPSRA/CTC
SUA-c2-XPSRA/CTC
SRA-c1-XPSRA/CTC
SP3-c1-SH1/CTC
SP3-c1-SH2/CTC
SR11-c1-XPSR1/CTC
SU1-c1-XPSR1/CTC
SU1-c2-XPSR1/CTC
SU2-c1-XPSR2/CTC
SU2-c2-XPSR2/CTC
SOR3-c1-SR42
SR31-c1-XPSR3/CTC
SU3-c1-XPSR3/CTC
SU3-c2-XPSR3/CTC
SP5-c1-SH3/CTC
SR41-c1-XPSR4/CTC
SU4-c1-XPSR4/CTC
SU4-c2-XPSR4/CTC
SR11-c1-SR12
SR22-c1-SR21
SR32-c1-SR31
SR22-c1-XPSR2/CTC
SR42-c1-SR52
ROC1-c1-SB1C
ROC2-c1-ROC1
BE1-e1-SB1C
BE2-f1-SB1C
BE3-e1-SB1C
SB1C-e1-SB1E
SB1C-f1-SB2B
SB1C-e1-SB3E
SOR3-c1-DQ3/CTC
DP1-p1-DQ5
DP1-p1-DQ6
DP1-c1-DQ5
DP1-c1-DP1ROC
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
SUA-c2-XPSRA/CTC
SRA-c1-XPSRA/CTC
SRA-c2-XPSRA/CTC
SOR1-c1-XPSRA/CTC
SOR4-c1-XPSRA/CTC
SP3-c1-SH1/CTC
SP3-c1-SH2/CTC
SR11-c1-XPSR1/CTC
SR11-c2-XPSR1/CTC
SU1-c1-XPSR1/CTC
SU1-c2-XPSR1/CTC
SOR1-c1-XPSR1/CTC
SOR4-c1-XPSR1/CTC
SOR2-c1-XPSR2/CTC
SOR4-c2-XPSR2/CTC
SU2-c1-XPSR2/CTC
SU2-c2-XPSR2/CTC
SOR3-c1-SR42
SOR2-c1-XPSR3/CTC
SOR9-c1-XPSR3/CTC
SOR2-c1-XPSR4/CTC
SOR9-c1-XPSR4/CTC
SR31-c1-XPSR3/CTX
SR31-c2-XPSR3/CTX
SU3-c1-XPSR3/CTC
SU3-c2-XPSR3/CTC
SP5-c1-SH3/CTC
SR41-c1-XPSR4/CTC
SR41-c2-XPSR4/CTC
SU4-c1-XPSR4/CTC
SU4-c2-XPSR4/CTC
SR11-c1-SR12
SR11-c1-SR12
SR22-c1-SR21
SR22-c1-SR21
SR32-c1-SR31
SR32-c2-SR31
SR22-c1-XPSR2/CTC
SR22-c2-XPSR2/CTC
SR42-c1-SR52
ROC1-c1-SB1C
ROC2-c1-ROC1
BE1-e1-SB1C
BE1-e2-SB1C
BE2-f1-SB1C
BE2-f2-SB1C
BE2-f3-SB1C
BE3-e1-SB1C
BE3-e2-SB1C
SB1C-e1-SB1E
SB1C-e2-SB1E
SB1C-f1-SB2B
SB1C-f2-SB2B
SB1C-f3-SB2B
SB1C-e1-SB3E
SB1C-e2-SB3E
DP1-p1-DQ5
DP1-c1-DQ5
DP1-c1-DP1ROC
1-1/2
1-1/2
1-1/2
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-4/C
1-15/C
1-15/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
2-1/C
3-1/C
3-1/C
1-4/C
1-20/C
4/0
4/0
4/0
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
600V
5000V
5000V
5000V
600V
600V
600V
600V
600V
600V
600V
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
DC BREAKER CONTROL PANEL
DC BREAKER CONTROL PANEL
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER TO DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
POWER FROM DC SWITCHBOARD
MAITENANCE SWITCH/INDICATING LIGHT
MAITENANCE SWITCH/INDICATING LIGHT
BREAKER OPEN/CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
SUA BUS 1 CONTROL CABINET
SUA BUS 2 CONTROL CABINET
SRA BUS 1 MAIN
SRA BUS 2 MAIN
SOR1
SOR4
SP3-7
SP3-8
SR11 MAIN
SR11 MAIN
SU1 BUS 1 CONTROL CABINET
SU1 BUS 2 CONTROL CABINET
SOR1
SOR4
SOR2
SOR4
SU3 BUS 1 CONTROL CABINET
SU3 BUS 2 CONTROL CABINET
SOR2
SOR2
SOR3
SOR9
SOR9
SOR9
SOR10
SOR2
SOR9
SOR2
SOR4
SR31 MAIN
SR31 MAIN
SU2 BUS 1 CONTROL CABINET
SU2 BUS 2 CONTROL CABINET
SP5-4
SR41 MAIN
SR41 MAIN
SU4 BUS 1 CONTROL CABINET
SU4 BUS 2 CONTROL CABINET
SR11 MAIN
SR11 MAIN
SR22 MAIN
SR22 MAIN
SR32 MAIN
SR32 MAIN
SR22 MAIN
SR22 MAIN
SR42 MAIN
ROC1
ROC2
BE1
BE1
BE2
BE2
BE2
BE3
BE3
SB1C-XE1
SB1C-XE1
SB1C-XF1
SB1C-XF1
SB1C-XF1
SB1C-XE2
SB1C-XE2
SOR3
DP1
DP1
DP1-XPD22
DP1
ZWT1
XPSRA/CTC
XPSRA/CTC
XPSRA/CTC
XPSRA/CTC
XPSRA/CTC
XPSRA/CTC
SH1/CTC
SH2/CTC
XPSR1/CTC
XPSR1/CTC
XPSR1/CTC
XPSR1/CTC
XPSR1/CTC
XPSR1/CTC
XPSR2/CTC
XPSR2/CTC
XPSR2/CTC
XPSR2/CTC
SQ0/5A
SQ0/5A
SR42 MAIN
SQ1/6A
SQ1/6A
SQ2/6A
SQ2/6A
XPSR3/CTC
XPSR3/CTC
XPSR4/CTC
XPSR4/CTC
XPSR3/CTC
XPSR3/CTC
XPSR3/CTC
XPSR3/CTC
SH3/CTC
XPSR4/CTC
XPSR4/CTC
XPSR4/CTC
XPSR4/CTC
SR12 MAIN
SR12 MAIN
SR21 MAIN
SR21 MAIN
SR31 MAIN
SR31 MAIN
XPSR2/CTC
XPSR2/CTC
SR52 MAIN
SB1C
ROC1
SB1C-XE1
SB1C-XE1
SB1C-XF1
SB1C-XF1
SB1C-XF1
SB1X-XE2
SB1X-XE2
SB1E
SB1E
SB2B
SB2B
SB2B
SB3E
SB3E
DQ3/CTC
DP1
DQ5
DQ6
DQ5 MS
DP1-ROC
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT AND EXISTING CABLE TRAY
NEW CONDUIT AND EXISTING CABLE DUCT
NEW CONDUIT AND EXISTING CABLE DUCT
NEW CONDUIT AND EXISTING CABLE DUCT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
350KCMIL CABLES ROUTED IN PARALLEL
CABLE AND CONDUIT SCHEDULE
(NOTE 2)
(NOTE 2)
(NOTE 2)
(NOTE 2)
(NOTE 2)
(NOTE 2)
REFERENCE DRAWINGS:
DDP-6-5/25
DDP-6-5/24
DDP-6-5/23
DDP-6-5/22
SUA-c1-XPSRA/CTC
DP1 FEEDER
DQ5 FEEDER
DQ6 FEEDER
600V14
1-3/C
1-3/C
1-3/C
1-3/C
1-3/C
1-3/C
SOR-c1-SQ1
SOR9-c1-SQ2
SQ0/5A-c1
XPSRA/CTC-c1
XPSR1/CTC-c1
XPSR2/CTC-c1
XPSR3/CTC-c1
XPSR4/CTC-c1
SOR2-c1-SQ0
SOR4-c1-SQ0
SOR9-c1-SQ1
SOR9-c2-SQ1
SOR9-c1-SQ2
SOR10-c1-SQ2
RCS-ZWT1
RCS-ZWT2
RCS-ZMT3
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
3/4
1-1/2
1-1/2
3-1/2
3-1/2
600V
600V
600V
600V
600V
600V
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
REMOTE OPEN AND CLOSE
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
NEW CONDUIT
RCS-ZMT5
RCS-ZMT7
ZWT2
NEW CONDUIT
ZMT3
ZMT5
ZMT7
ZMT10 RCS-ZMT10
SB1C-c1-SB1E
10SB1C-c1-SB3E 3/4
3/4 10 SB1C-c1-SB1E
SB1C-c1-SB2A
SB1C-c1-SB2B
SB1C-c1-SB1E
SB1C-c1-SB2B 3/4 10
1-2/C
1-2/C
1-2/C
1-2/C
600V
600V
600V
600V
ANNUNCIATION
ANNUNCIATION
ANNUNCIATION
ANNUNCIATION
SB1E NEW CONDUIT AND EXISTING TRAY
SB2A NEW CONDUIT AND EXISTING TRAY
SB2B NEW CONDUIT AND EXISTING TRAY
SB3E NEW CONDUIT AND EXISTING TRAY
SB1CXE1
SB1CXF1
SB1CXF1
SB1CXE2
SOR3-c1-DQ3/CTC 1-8/C
PBZWT2-c2-PBZMT3
PBZMT3-c2-PBZMT4
PBZMT4-c2-PLCZ
1-1/2
2-1/2
1-9/C 14 600V 790 CONTROL PBZWT1 PLCZ NEW CONDUIT
(NOTE 3)
3.DUPLICATE NEW CONDUIT NOT BOLDED.
2.CABLE IS ROUTED THROUGH VARIOUS CONDUITS.
1.CABLE AND CONDUIT SCHEDULES
1-9/C 14 600V 610 CONTROL ZWT2 PLCZ NEW CONDUIT
2-1/2
2-1/2
1-9/C 14 600V 430 CONTROL ZMT3 PLCZ NEW CONDUIT
1-1/2
2-1/2
2-1/2
2-1/2
2-1/2
ZMT10G-c1-PLCZ 1-9/C 14 600V 1210 CONTROL ZMT10 PLCZ NEW CONDUIT
1-9/C 14 600V 510 CONTROL ZMT7 PLCZ NEW CONDUIT
1-9/C 14 600V 150 CONTROL ZMT5 PLCZ NEW CONDUIT
3/4
3/4
3/4
3/4
3/4
3/4
ZWT1-c1-ZWT1G
ZWT2-c1-ZWT2G
ZMT3-c1-ZMT3G
ZMT5-c1-ZMT5G
ZMT7-c1-ZMT7G
ZMT10-c1-ZMT10G
3/4
3/4
3/4
3/4
3/4
3/4 10
10 ZWT1-c1-ZWT1G
ZWT2-c1-ZWT2G
ZMT3-c1-ZMT3G
ZMT5-c1-ZMT5G
ZMT7-c1-ZMT7G
ZMT10-c1-ZMT10G 1-2/C
1-2/C
1-2/C
1-2/C
1-2/C
1-2/C 10
ZWT2
ZMT3
ZMT5
ZMT7
ZMT10 ZMT10G
ZWT1G
ZWT2G
ZMT3G
ZMT5G
ZMT7G
PBZMT7-c2-PBZMT6
PBZMT10-c2-PBZMT9
PBZMT9-c2-PBZMT8
ZWT1
ZWT1G-c1-Z1RCS
ZWT2G-c1-Z2RCS
ZMT3G-c1-Z3RCS
ZMT5G-c1-Z5RCS
ZMT7G-c1-Z7RCS
ZMT10G-c1-Z10RCS
ZWT1G-c1-Z1RCS
ZWT2G-c1-Z2RCS
ZMT3G-c1-Z3RCS
ZMT5G-c1-Z5RCS
ZMT7G-c1-Z7RCS
ZMT10G-c1-Z10RCS
XPWH-p1-DP1 XPWH-p1-DP1 XPWH NEW CONDUIT AND EXISTING CABLE DUCT485 2225
PBZWT2-c1-PBZMT3 180
PBZMT3-c1-PBZMT4 180
PBZMT4-c1-PLCZ 190
180PBZMT3-c1-PBZMT4
PBZMT4-c1-PLCZ 190
PBZMT6-c2-PBZMT5 180
90PBZMT5-c2-PLCZ
PBZMT5-c2-PLCZ 90
ZMT5G-c1-PBZMT5
ZWT1G-c1-PLCZ
ZWT2G-c1-PBZWT2
ZWT1G-c1-PBZWT1
DP1-p1-DQ6
ZMT3G-c1-PBZMT3
ZWT2G-c1-PLCZ
ZMT3G-c1-PLCZ
ZMT10G-c1-PBZMT10
PBZMT8-c2-PBZMT7
PBZMT7-c2-PBZMT6
PBZMT6-c2-PBZMT5
PBZMT5-c2-PLCZ
ZMT7G-c1-PBZMT7
ZMT7G-c1-PLCZ
PBZWT1-c2-PBZWT2, 3"
ZMT5G-c1-PLCZ
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
120VAC
4160VAC
4160VAC
4160VAC
4160VAC
125VDC
125VDC
125VDC
250VDC
250VDC
250VDC
125VDC
125VDC
125VDC
125VDC
250VDC
250VDC
250VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125VDC
125…