NOTES:

G

H D

C S

D C

P -1 .1

-6 -0 /3

SEE NOTE 8

JOINT

CONTRACTION

SEE NOTE 8

EL 202.0

HOUSING FLANGE

EL 205.0

EL 185.0

RELIEF DEVICE

FOR PRESSURE

DISCHARGE PIPING

SEE NOTE 7

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

P O

R T

L A

N D D

IS

T R

IC

T

PORTLAND DISTRICT

S T

E V

E N R

M

IL

E S P .E

G

H D

C E

V H

A P

E S

O L

A

E-101

P O

W E

R H

O U

S E

C O

L U

M B

IA

R

IV

E R O

R A

N D W

A

A N

S I

D

SYSTEM (COPS) TANK

CONSTANT OIL PRESSURE

LOCATION

GROUND

LOCATION

GROUND

VALVE

3" DRAIN

EL 185.0

(TYP)

PENETRATION

PIPING DECK

OIL SUPPLY

RELIEF DEVICE

FOR PRESSURE

PIPING

DISCHARGE

PENETRATION

PIPING DECK

OIL DRAIN

DEVICE

RELIEF

PRESSURE

U P

S T

R E

A M

EMBEDDED CONDUITS

LOCATION OF EXISTING

DDP-1-6-1E/11 FOR

DDP-1.3-6-1E5/1 AND

SEE REF. DRAWINGS

SEE NOTE 2

18'-0"

FOR CLARITY

AS PHANTOM LINE

COPS TANK SHOWN

EL 203.0

7'-2"

VARIES

6'-6" 7'-7"

8'-3"

SEE NOTE 7

SEE NOTE 4

EMBEDDED IN DECK

UNDER TRANSFORMER

GROUND LOCATION

EMBEDDED IN DECK

UNDER TRANSFORMER

GROUND LOCATION

CABINET

CONTROL

CABINET

POWER

BOX

ENTRANCE

CONDUIT

HI

H0 X2 X1

11"

21"

31'-7"31'-7"

JOINT

CONTRACTION

MAIN DRAIN VALVE

VALVE

LOWER SERVERON

GAUGES

VALVE

FILL

UPPER

VALVE

SERVERON

UPPER

EL 190.0

RESERVED

AREA

VALVE

FILL

UPPER

RESERVED

AREA

RESERVED

AREA

VALVE

LOWER FILTER

VALVE

MAIN DRAIN

VALVE

FILTER

LOWER

CABINET

CONDUIT ENTRANCE

MIN

3'

MIN

3'

13'-0"

24"

14"

FOR SERVERON WIRING

CONDUIT CAPPED

1 1/2"

SEE NOTE 9

SEE NOTE 9

THE POWERHOUSE GROUNDING SYSTEM (BY OTHERS).

THE TANK GROUNDING PADS SHALL BE BONDED TO

STRAP CONNECTION TO THE TANK GROUNDING PADS.

10. TRANSFORMER BUSHINGS SHALL HAVE A GROUND

SUPPLIED AND INSTALLED BY OTHERS.

UNISTRUT TO WHICH GAS/OIL ANALYZER WILL BE

9. SUPPORT BEAMS FOR FASTENING 1 5/8" DEEP

PARAGRAPH 2.6.9.

SEE SPECIFICATIONS SECTION 48 19 23.01

BASE. TO BE SHIPPED PRIOR TO TRANSFORMER.

8. SUPPLY SEPARABLE STRUCTURAL STEEL SUPPORTING

CONNECTION TO EXISTING BUS WORK.

7. BUSHING LOCATIONS ARE FIXED TO FACILITATE

BOTTOM OF TRANSFORMER TANK.

THE BASE OF THE TRANSFORMER AT EXTREME

THE MAIN DRAIN VALVE IS LOCATED 16" ABOVE

AND SHALL BE SIZED SUCH THAT THE CENTER OF

CLOSER THAN 8" TO THE CONTRACTION JOINT,

OVERLAP CONTRACTION JOINT, SHALL BE NO

6. TRANSFORMER STRUCTURAL STEEL BASE SHALL NOT

AND CONDITIONS.

5. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS

4. VERTICAL DRAFT LOW NOISE FANS AS REQUIRED.

AND DDP-1-6-1E/1)

POWERHOUSE. (SEE DRAWINGS E-402, E-405

CIRCUITS FROM THE CABINET INTO THE

ROUTING TRANSFORMER CONTROL AND RELAYING

CONDUIT BLOCK OUT SHOWN CAN BE USED FOR

CABINET SO THAT THE EXISTING EMBEDDED

SHALL INCLUDE CONDUIT TO A CONDUIT ENTRANCE

3. THE TRANSFORMER CONTROL CABINET LOCATION

VOLTAGE BUS.

DDP-1-6-1A5/5 FOR EXISTING TRANSFORMER LOW

2. SEE REFERENCE DRAWING DDP-56-162-16 AND

F. VAULT OPENINGS

CABINET

E. CONTROL CABINET AND CONDUIT ENTRANCE

D. OIL DRAIN VALVE

C. HIGH-VOLTAGE NEUTRAL BUSHING

B. LOW-VOLTAGE BUSHINGS

A. HIGH-VOLTAGE BUSHING

TRANSFORMER INSTALLATION.

ALLOW FOR PROPER INTERCONNECTION DURING

TRANSFORMER APPURTENANCES, AS INDICATED, TO

GIVEN TO THE DESIGN AND PLACEMENT OF THE

MAINTENANCE. PARTICULAR ATTENTION SHOULD BE

TO ASSURE ADEQUATE SPACE FOR FUTURE

AND THE VAULT STRUCTURE HAVE BEEN INDICATED

LIMITING DIMENSIONS BETWEEN THE TRANSFORMER

INTERCONNECTION TO THE EXISTING POWERPLANT.

DESIGNING THE TRANSFORMER FOR PROPER

PROVIDED FOR THE MANUFACTURER'S USE IN

INDICATED ON THIS DRAWING HAVE BEEN

1. THE TRANSFORMER LAYOUT AND DIMENSIONS AS

EMBEDDED IN DECK

UNDER TRANSFORMER

GROUND LOCATION DETAIL ON SHEET E-301)

GROUNDING COVER (SEE

CORE AND CORE FRAME

SEE NOTE 9

ITEMS

FOR FUTURE

RESERVED

SPACE

X2 H0

X1

HI

X2 H0

X1

HI

D

IM

E N

S

IO

N S

T

R A

N F

O R

M E

R B

A N

K T I

L A

Y O

U T A

N D L

IM

IT

IN

G D

D P .1

E -1

X X

X .d g n

/0

/2

G S

U T

R A

N S

F O

R M

E R S

U P

P L

Y

T H

E D

A L L E

S L

O C

K A

N D D

A M

W

N -1

-R -0

-1

-2

C H

G E -4

E -4

W

E R

E E -0

E -0

B J B

B

A

VIEW A-A TRANSFORMER BANK T1 EL 185.00

SCALE: 3/16" = 1'-0'

SCALE: 3/16" = 1'-0'

ELEVATION TRANSFORMER BANK T1 - EL 185.0

B

SCALE: 3/16" = 1'-0"

SECTION

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K

D A

T E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

D A

T E

A P

P R

D R

A W

IN

G N

U M

B E

R of Engineers

US Army Corps

P L

O T D

A T

E

54321

D

C

B

A

/1

/2 n w d \n w p \E

T D

S \C

A D

D -W o rk s p a c e s \N

W P \W o rk

S p a c e \p ro je c ts \L o c a l R e s o u rc e

D E

S

IG

N F

IL

E

BORDER VERSION UPDATE [09-2012]

E-101SHEET NAME:g2hdcjpr BY USERNAME:ANSI DDRAWING PLOT SIZE: DATE AND TIME PLOTTED: 10/16/2015 3:38:51 PM

D R

A W

N B

Y

C H

E C

K E

D B

Y

File details come from the government source that posted it. Updated .