Final_Ft._Bliss_B1717-Att_B-Drawings_4o4.pdf
PDF 30 MB Posted
- Attached to
- Buildings 1717 & 1735 renovation
- Solicitation number
- W9126G19B0010
About this file
RFP # W9126G19B0010 - Att B - Drawings 4 of 4
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
D1
E1
F1
G1
H
K
1 32 1 3
A
2 4 5 6 7 8 9
B
D1
E1
1 32 4 5 6 7 8 9
F1
G1
H
K
1610 11 12 13 14 15
1610 11 12 13 14 154.1 5.1
L
M
PANEL LF (DEMO)
PANEL E1 (DEMO)
PANEL E2 (DEMO)
XFMR TLF
(DEMO)
PANEL LM (DEMO)
RTU-3
(DEMO)
RTU-2
(DEMO)
RTU-1
(DEMO)
AC2
(DEMO)
MULTIZONE
(DEMO)
EXISTING CHILLERS 1 AND 2 TO BE REPLACED, CHILLER
2 TO REMAIN UNTIL THE NEW CHILLER 1 IN INSTALLED
AND CHANGEOVER IS COMPLETE, THEN CHILLER 2 TO
BE REPLACED WITH NEW CHILLER.
M
MM HEATING UNIT
(DEMO)
M HEATING UNIT
(DEMO)
M FC
(DEMO)
J (D)
JJ (D)
(D) (D)
(D)
HEATING UNIT
(DEMO)
EXISTING GENERATOR AND ASSOCIATED ATS, XFMR,
AND TRANSFORMER TO BE DEMOLISHED.
EXISTING UTILITY TRANSFORMER TO BE
REPLACED WITH NEW IN NEW LOCATION SHOWN
ON SHEET EP400. EXISTING TRANSFORMER AND
SERVICE TO BE REMOVED AFTER NEW
TRANSFORMER AND SERVICE IS INSTALLED.
COORDINATE WORK WITH UTILITY COMPANY.
EX-HWP-3
EX-CHWP-4
EX-HWP-1
EX-CHWP-1
TO REMAIN UNTIL
NEW CHILLERS
ARE INSTALLED
EXISTING FACP & CONTROLS
BOARD TO REMAIN UNTIL NEW
FACP AND CONTROLS ARE IN
PLACE AND FUNCTIONING
AHU
(DEMO)
UH
(DEMO)
FAN
(DEMO)
M
M
EXISTING FCU (9) TO REMAIN
UNTIL NEW CHILLED WATER
SYSTEM IS OPERATING REFER
TO MECHANICAL PLANS FOR
MORE INFORMATION.
UH
(DEMO)
EXISTING FCU(3) TO REMAIN
UNTIL NEW CHILLED WATER
SYSTEM IS OPERATING REFER
TO MECHANICAL PLANS FOR
MORE INFORMATION.
AC1
(DEMO)
UH (DEMO)
(TYPICAL)
M
M
EXISTING FANCOIL (FC7) TO
REMAIN IN OPERATION,
DEMO AFTER NEW WORK IN
RESTROOMS IS COMPLETE.
EXHAUST FAN TO BE
REPLACED WITH NEW FAN.
EXISTING SPLIT SYSTEM UNIT
TO REMAIN IN OPERATION
UNTIL NEW COOLING
SYSTEMS ARE OPERATIONAL.
APPROXIMATE LOCATION OF
EXISTING PHOTOCELL,
REMOVE EXISTING CONDUIT
FEEDING PHOTOCELL ON
FACE OF BUILDING.
APPROXIMATE LOCATION OF
EXISTING WALL PACK LIGHT
FIXTURES FED FROM
CONDUITS ON FACE OF
BUILDING. LIGHT FIXTURES
TO BE REPLACED. REMOVE
CONDUIT AND PATCH/FILL
WALL PENETRATIONS.
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
B U
IL
D
IN
G
- E
LE
C
TR
IC
A L
D
EM
O
LI
TI
O
N P
LA
N
S
JT
H
JR
D
JT
H
ELECTRICAL DEMOLITION NOTES
1. ALL ELECTRICAL EQUIPMENT/DEVICES ARE EXISTING TO BE REMOVED UNLESS
OTHERWISE NOTED. REFER TO EF100, EL100, EP100, AND T-100 SERIES SHEETS
FOR MORE INFORMATION. REUSE AND MAINTAIN EXISTING CIRCUITRY
SERVING EXISTING EQUIPMENT AND DEVICES THAT ARE TO REMAIN OR ARE TO
BE REPLACED IN EXISTING LOCATIONS.
2. VERIFY JOB SITE CONDITIONS WITH THE SCOPE OF ELECTRICAL WORK
INVOLVED, WORK SHALL INCLUDE MATERIALS, EQUIPMENT, APPURTENANCES,
WHICH MUST BE REROUTED, RELOCATED OR REMOVED EITHER TEMPORARILY
OR PERMANENTLY, OR WHICH MUST BE PROVIDED TO ACCOMPLISH THE
INDICATED REMODELING.
3. DO NOT REUSE EXISTING LIGHT FIXTURES, UNLESS OTHERWISE NOTED.
REMOVED FIXTURES SHALL BE DELIVERED TO THE OWNER, FIELD VERIFY
LIGHT FIXTURE COUNT AND LOCATIONS PRIOR TO COMMENCING WORK.
4. RE-ESTABLISH SERVICE TO ALL DEVICES THAT MAY BE INTERRUPTED BECAUSE
OF REMODELING WORK.
5. DISCONNECT AND REMOVE ALL ASSOCIATED BRANCH CIRCUITS BACK TO
PANEL SERVICE THEM AND ALL ASSOCIATED PANELS.
6. WHEN DEVICES ARE REMOVED, DEVICE AND WIRE SHALL BE PULLED OUT BACK
TO NEXT BOX. IF CONDUIT AND/OR BOX IS EXPOSED, IT MUST BE REMOVED.
PLACE A BLANK COVER OVER REMAINING BOXES. ON WALLS THAT ARE BEING
FURREDOUT, THE REMAINING BOXES WILL BE LEFT WITHOUT A COVER AND
THE CONDUIT CAPPED IN THE PLENIUM.
7. ALL RECEPTACLES, TELEPHONES AND DATA OUTLETS SHOWN ON THE PLANS
ARE NEW UNLESS NOTED OTHERWISE.
8. NEW SWITCHES SHALL BE INSTALLED IN ALL AREAS THAT ARE TO BE
REMODELED.
9. REMOVE ALL UNUSED AND DEMOLISHED CONDUIT AND WIRE BACK TO PANEL.
10. ALL DEVICES ARE NOT SHOWN ON PLAN. CONTRACTOR TO VISIT SITE AND
VERIFY QUANTITY AND CIRCUITS.
11. IN AREAS WHERE CEILING IS TO BE REMOVED, REMOVE ALL CEILING MOUNTED
SMOKE DETECTORS AND MAINTAIN ADEQUATE FIRE/SMOKE DETECTION
COVERAGE DURING THE INTERIM. EXISTING FIRE ALARM SYSTEM IN THE
BUILDING IS ADDRESSABLE TYPE. PROVIDE TEMPORARY WIRING AS REQUIRED
TO MAINTAIN OPERATIONAL SYSTEM IN THE DEMOLISHED AREA AND AN
OPERATIONAL SYSTEM IN THE ADJACENT "CIF" AREA THAT IS
NOT-IN-CONTRACT.
12. ALL EXISTING FLOOR RECEPTACLES AND CIRCUITS TO BE REMOVED. PROVIDE
AND INSTALL BLANK PLATES ON REMAINING FLOOR BOXES.
13. INSTALLING CONTRACTOR TO SUB-CONTRACT RGEC TO PERFORM THE
DESCRIBED DEMOLITION AND INSTALLATION OF RGEC WIRING AND EQUIPMENT.
ED101
A B C
F E D
30' 0' 30' 60'15'
SCALE: 1" = 30'-0"
Scale: 1"=30'-0"A2
BUILDING 1717 - SECOND FLOOR
ELECTRICAL DEMOLITION PLAN
Scale: 1"=30'-0"A5 BUILDING 1717 - FIRST FLOOR ELECTRICAL DEMOLITION PLAN
SYMBOL SYMBOL
FIRE ALARM SYMBOLS
FIRE ALARM CONTROL UNIT AND
FIRE ALARM REMOTE ANNUNCIATOR
FIRE ALARM STROBE (VISUAL SIGNALING
APPLIANCE) *
SMOKE DETECTOR-SUBSCRIPT INDICATES
PHOTOELECTRICAL SMOKE DETECTOR
WITH SOUNDER BASE
DESCRIPTION
INTERFACING CONTROL RELAY TO
INTERFACE WITH ELEVATOR CONTROL
PANEL FOR AUTO RECALL
TAMPER SWITCH
LINE ISOLATOR MODULE
FLOW SWITCH
END OF LINE RESISTOR
CONTROL MODULE
DESCRIPTION
EXPANSION MODULE
DOOR HOLD/DOOR HOLD OPENCLEAR STROBE WITH SPEAKER *
STROBE BOOSTER PANEL
MANUAL PULL STATION
MONITOR MODULE
MASS NOTIFICATION CONTROL UNIT
SPEAKER *
JACK FOR FIREMAN'S TELEPHONE
FIRE ALARM CONNECTION TO ANCILLARY
KITCHEN HOOD FIRE SUPPRESSIONI - IONIZATION P - PHOTOELECTRIC
HEAT DETECTOR - COMBINATION FIXED
AND RATE-OF-RISE U.N.O.
DUCT SMOKE DETECTOR - PHOTOELECTRIC
U.N.O; COORDINATE LOACATION W/ MECH
RELAY TO BE CONTROLLED BY SIGNAL
FROM FIRE ALARM SYSTEM.
FLOW SWITCH ALARM BELL. COORDINATE
EXACT LOCATIONS WITH FIRE MARSHALL.
PANEL
DB VALUE ADJACENT TO SPEAKERS INDICATES INTENDED VOLUME OF SPEAKER AT THIS LOCATION
ADJUST TAPS ON SPEAKER SO AS TO ACHIEVE INDICATED DB VALUE
* cd NUMBER STROBES AND SPEAKER OR HORN/STROBES INDICATED CANDELA VALUE.
I/E/P
E - ELEVATOR RECALL
EMERGENCY VOICE/ALARM
COMMUNICATION SYSTEM CONTROL UNIT
FIRE DEPARTMENT TWO-WAY
COMMUNICATION SYSTEM CONTROL UNIT
GENERATOR REMOTE ANNUNCIATOR
PANEL
ELEVATOR REMOTE ANNUNCIATOR
PANEL
E
E - ELEVATOR RECALL
DIGITIAL ALARM COMMUNICATING
TRANSMITTER, 2 DEDICATED PHONE LINES
SYSTEM INPUT
SYSTEM OUTPUT
MANUAL FIRE ALARM PULL STATIONS
AREA SMOKE DETECTORS
HVAC IN-DUCT SMOKE DETECTORS
AREA HEAT DETECTORS
FIRE SPRINKLER WATER FLOW SWITCH
FIRE SPRINKLER TAMPER SWITCH
LOW/HIGH LEVEL/TEMP/PRESSURE SWITCHES
FIRE ALARM SYSTEM AC POWER FAILURE
OPEN CIRCUIT
GROUND FAULT
NOTIFICATION APPLIANCE CIRCUIT SHORT
NOTE - REFER TO FIRE ALARM SPECIFICATION FOR ADDITIONAL SEQUENCE OF OPERATION INFORMATION.
FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX
LEGALLY REQUIRED GENSET SYSTEM LOW FUEL
LEGALLY REQUIRED GENERATOR NOT IN AUTOMATIC
FIRE ALARM SYSTEM LOW BATTERY
FIRE SPRINKLER POST INDICATOR VALVE SWITCH
AC
TU
AT
E
C O
M M
O N
A
LA
R M
S
IG
N
AL
AC
TU
AT
E
AU
D
IB
LE
A
LA
R M
S
IG
N
AL
AC
TU
AT
E
C O
M M
O N
S U
PE
R
VI
SO
R Y
SI
G
N
AL
IN
D
IC
AT
O R
AC
TU
AT
E
AU
D
IB
LE
S U
PE
R
VI
SO
R Y
SI
G
N
AL
AC
TU
AT
E
C O
M M
O N
T R
O U
BL
E
SI
G
N
AL
IN
D
IC
AT
O R
AC
TU
AT
E
AU
D
IB
LE
C O
M M
O N
T R
O U
BL
E
SI
G
N
AL
AC
TI
VA
TE
V
IS
U
AL
/A U
D
IO
F
IR
E
AL
AR
M
D
EV
IC
ES
D
IS
PL
AY
/P R
IN
T
C H
AN
G
E O
F
ST
AT
U
S
TR
AN
SM
IT
A U
TO
M
AT
IC
A
LA
R M
S
IG
N
AL
T O
S U
PE
R
VI
SI
N G
S
TA
TI
O
N
TR
AN
SM
IT
M
AN
U
AL
S
IG
N
AL
T O
S U
PE
R
VI
SI
N G
S
TA
TI
O
N
TR
AN
SM
IT
W
AT
ER
F
LO
W
S
IG
N
AL
T O
S U
PE
R
VI
SI
N G
S
TA
TI
O
N
TR
AN
SM
IT
S U
PE
R
VI
SO
R Y
SI
G
N
AL
T O
S U
PE
R
VI
SI
N G
S
TA
TI
O
N
TR
AN
SM
IT
G
EN
ER
AL
T R
O U
BL
E
SI
G
N
AL
T O
S U
PE
R
VI
SI
N G
S
TA
TI
O
N
R
ES
TO
R
E
EM
ER
G
EN
C
Y
LI
G H
TI
N
G
U N
LO
C
K N
EC
ES
SA
R
Y
EG
R
ES
S
EX
IT
S
SH
U
T D
O W
N A
SS
O
C
IA
TE
D
F
AN
AC
TU
AT
E
FI
R
E
AL
AR
M
B
EL
L
CONTROL UNIT ANNUNCIATION
A B C D E F G H I J K L M N O P Q R S T U V
X
NOTIFICATION REQUIRED FIRE
SAFETY
CONTROL
SUPPLEMENTARY
AC
TI
VA
TE
F
IR
E
AL
AR
M
B
AT
TE
R
Y
BA
C K-
U P
X X X X X X
X X X X X X X X
X X X X X X X X
X X X X X X X X
X X X X X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X
X
XX X X X
X X X X
X X X X
SIGNAL SILENCE ACTIVATED
D
EA
C
TI
VA
TE
A U
D
IB
LE
S
IG
N
AL
S
D
EA
C
TI
VA
TE
V
IS
IB
LE
S
IG
N
AL
S
R
ES
ET
4V
-W
IR
E D
EV
IC
ES
SY
ST
EM
N
O R
M
AL
S
TA
TU
S
RESET FACP
X X
X X X X
X
FIRE ALARM GENERAL NOTES
PAM-1 RELAY/INTERFACE RELAY
#12/2 FPLR-SH
ADDRESSABLE
FIRE ALARM
CONTROL PANEL
GAP
FAAP
#12/2 FPLP-SH & #12/2 FPLP
BUILDING 1717
NOTIFICATION
APPLIANCE
CIRCUIT
EXTENDER
MODULE
STROBE
CIRCUITS
(2)#12/2 FPLR-SH
MECH ROOM
(TYP)
(TYP) FIRE SPRINKLER
FLOW & TAMPER
SWITCH (TYP)
AHU RETURN
DUCT SMOKE
DETECTOR (TYP)
RELAY
W/ MOTOR
START/STOP
& STATUS
INDICATOR
#12/2 FPLP
#12/2 FPLP
(2) #12/2 FPLP
#12/2 FPLP-SH
#12/2 FPLP-SH
(2) #12/2 FPLP-SH
AUDIO
AMPLIFIER
CABINET
VOICE
CIRCUITS
(2)#12/2 FPLR-SH
B
P
S FS
TS
HO
ER
CM
MM
LIM
FAAP
FACP
F
KH
R
B
EOL
EVCS
FDCS
GAP
EAP
MT
DH
PAM
DIGITAL ALARM
COMMUNICATING
DEDICATED
PHONE LINE 1
DEDICATED
PHONE LINE 2 TRANSMITTER
P
TSFS
MM
RETURN
R
S
EXISTING
ADDRESSABLE
FIRE ALARM
CONTROL PANEL
(LOCATED IN CIF
LOADING DOCK)
ELEC ROOM
(TYP)
FIRE ALARM PLAN KEYNOTES
APPROXIMATE LOCATION OF MASS NOTIFICATION AND FIRE ALARM SYSTEM CONTROL
PANEL(S). PROVIDE MICROPHONE FOR ISSUING INSTRUCTIONS, REFER TO SPECIFICATION.
PROVIDE A CONNECTION FROM THE FIRE ALARM PANEL TO THE BASE MONOCO SYSTEM.
PROVIDE INTERCONNECTION WITH THE MASS NOTIFICATION SYSTEM SO AS TO ALLOW
BROADCAST OF SPECIFIC AUDIO MESSAGES. COORDINATE EXACT LOCATION OF PANEL
WITH EXISTING ITEMS THIS ROOM.
FIRE ALARM SYSTEM REMOTE ANNUNCIATOR PANEL. COORDINATE EXACT LOCATION(S) OF
REMOTE ANNUNCIATOR PANEL WITH ARCHITECTURAL DETAILS PRIOR TO ROUGH-IN.
FA
SPEAKER
(TYP)
FA
STROBE
(TYP)
FA
STROBE/
SPEAKER
(TYP)
1. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS 'FIRE ALARM CIRCUIT CONTROL'. THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE
ALARM CONTROL PANEL.
2. ANY SMOKE DETECTOR HEAD INSTALLED PRIOR TO THE BUILDING BEING CLEANED AND ACCEPTED
SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED
HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.
3. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTIONS OF THE NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER
LIMITED AND NON-POWER LIMITED WIRE.
4. FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM AND OTHER SPACES USED FOR ENVIRONMENTAL
AIR SHALL BE TYPE FFLP.
5. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR
OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FFLP.
6. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE
UL LISTED FOR WET LOCATIONS.
7. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE
INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 725, 760, 770 AND 800 WHERE APPLICABLE.
8. ALL WIRING INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. ALL
SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.
9. ONLY FIRE ALARM SYSTEM WIRING IS ALLOWED IN SINGLE CONDUIT, 120VAC CIRCUITS ARE NOT
PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE FIRE ALARM WIRING.
10. DUCT DETECTORS SHALL BE PROVIDED IN THE SUPPLY DUCT OF ALL HVAC UNITS RATED AT 2,000CFM OR GREATER, AND IN THE RETURN AND SUPPLY DUCT OF ALL HVAC UNITES RATED AT
15,000CFM OR GREATER. LOCATED DETECTORS IN ACCORDANCE WITH NFPA 72. REFER TO
MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL DUCT SMOKE DETECTORS.
11. ALL MONITOR MODULES TO BE MOUNTED BELOW THE CEILING AND VISIBLE FOR PROPER
ANNUNCIATION.
12. WALL-MOUNTED APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN
80" AFF AND NOT GREATER THAN 96" AFF. WHERE LOW CEILING HEIGHTS DO NOT PERMIT
MOUNTING AT A MINIMUM 80" AFF, VISIBLE APPLIANCES SHALL BE MOUNTED WITHIN 6" OF THE CEILING. THE ROOM SIZE COVERED BY A STROBE OF A GIVEN VALUE SHALL BE REDUCED BY TWICE THE DIFFERENCE BETWEEN THE MINIMUM MOUNTING HEIGHT OF 80" AFF AND THE ACTUAL LOWER
MOUNTING HEIGHT.
13. ALL MANUAL PULL STATIONS SHALL BE WALL MOUNTED 42" - 48" AT ACTIVATION LEVEL ABOVE
FINISHED FLOOR AND NOT GREATER THAN 5' FROM DOOR APPROXIMATELY WHERE SHOWN.
14. ALL SMOKE DETECTORS TO BE CEILING MOUNTED APPROXIMATELY WHERE SHOWN AND NOT LESS
THAN 4' FROM ANY SUPPLY OR RETURN VENTS OR WALL MOUNTED WITH THE TOP OF THE
DETECTOR LOCATED AT 8" BELOW THE CEILING.
15. SPOT-TYPE SMOKE DETECTORS SHALL BE LOCATED ON THE CEILING NOT LESS THAN 4" FROM A
SIDEWALL TO THE NEAR EDGE OR, IF ON A SIDEWALL, BETWEEN 4" AND 12" DOWN FROM THE
CEILING TO THE TOP OF THE DETECTOR.
16. PROVIDE GUARD FOR ALL FIRE ALARM SYSTEM INDICATING DEVICES WHERE SUBJECT TO
MECHANICAL DAMAGE. GUARDS SHALL BE LISTED FOR USE WITH PROTECTED DEVICE. PROVIDE
WEATHER-PROOF ENCLOSURE FOR ALL FIRE ALARM SYSTEM INDICATING DEVICES WHERE
SUBJECT TO DIRECT OR IN-DIRECT MOISTURE. WEATHER-PROOF ENCLOSURE SHALL BE LISTED
FOR WET LOCATIONS WITH PROTECTED DEVICE.
17. FIRE ALARM CONTROL PANEL AND REMOTE FIRE ALARM CONTROL PANELS SHALL HAVE INTEGRAL
BATTERY BACKUP AND BE CIRCUITED TO AN EMERGENCY LIFE SAFETY PANEL CIRCUIT.
18. VISIBLE NOTIFICATION DEVICES SHALL NOT BE LOCATED MORE THAN 15' FROM THE END OF A CORRIDOR WITH A SEPARATION OF NOT GREATER THAN 100' BETWEEN DEVICES. DEVICES SHOWN WERE SPACED ACCORDING TO NFPA 72 -ROOM SPACING FOR WALL AND CEILING MOUNTED VISIBLE
APPLIANCES.
19. DUCT DETECTORS SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR AND
WIRED BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL WIRE THROUGH THE
DETECTORS FOR FAN SHUT-DOWN. ELECTRICAL CONTRACTOR SHALL WIRE THE DETECTORS TO
THE FIRE ALARM CONTROL PANEL. A NORMALLY CLOSED CONTACT IN THE DETECTOR BASE SHALL
BE PROVIDED BY THE ELECTRICAL CONTRACTOR FOR FAN SHUT-DOWN. COORDINATE WITH
MECHANICAL CONTRACTOR.
20. FIRE ALARM CONTROL PANEL TO BE PROVIDED WITH ADDRESSABLE MONITOR MODULES FOR ATS
MONITORING, EMERGENCY GENERATOR STATUS MONITORING.
21. FOR FIRE ALARM INITIATING DEVICE CIRCUITS, THE FIRE ALARM SYSTEM WIRING SHALL BE CLASS
"A", STYLE "6" OR DEPARTMENT OF PUBLIC WORKS APPROVED STYLE. FOR SIGNALING LINE
CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS, FIRE ALARM SYSTEM WIRING SHALL BE CLASS
"A", STYLE "Z" OR DEPARTMENT OF PUBLIC WORKS APPROVED STYLE.
22. FIRE ALARM SYSTEM SHALL BE AN INTEGRATED RADIO TRANSRECEIVER AND FIRE ALARM CONTROL PANEL FOR THE NARROWBAND D-21 CAPABILITIES, FREQUENCY OF 167.5250 MHZ, SERIAL NUMBER AR 182427 WITH BTX INTERFACE. BTX INTERFACE TO INCLUDE FIRE, MASS NOTIFICATION, AND
RELAY CARDS.
23. WORK SHALL BE PERFORMED BY A LICENSED/CERTIFIED FIRE ALARM ENGINEER SYSTEM
SUB-CONTRACTOR TO INSTALL A COMPLETE AND FULLY OPERATING FAS.
* WP INDICATES DEVICE PROVIDED WITH WEATHERPROOF ENCLOSURE.
* NOT ALL SYMBOLS WILL BE USED.
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
07/24/2019
B U
IL
D
IN
G
- F
IR
E
A
LA
R M
G
EN
ER
A
L N
O
TE
S, SY
M B
O
LS
L
EG
EN
D
, A N
D F
IR
E
A
LA
R M
R
IS
ER
D
IA
G
R A
M
JT
H
JR
D
JT
H
EF001
AutoCAD SHX Text F1
AutoCAD SHX Text F2
1 3
2 4 5
B
D1
E1
FS
TS
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
75cd 76dB
30cd 79dB
30cd 79dB
15cd 79dB
30cd 79dB
30cd 79dB
15cd
75cd 76dB
75cd 76dB
30cd 79dB
30cd 76dB
30cd 79dB
75cd 79dB
P
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB 75cd
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
15cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
15cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
15cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd
S 76dB
S 76dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB 30cd
30cd
S 76dB
S 76dB
S 76dB
30cd 79dB
S 76dB
75cd S
76dB S
76dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd
30cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB 30cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S S
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB75cd
79dB 75cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB75cd
79dB 75cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S
89dB
WP S
89dB
WP
S
89dB
WP
S 89dB
WP
S 89dB
WP
RTAHU-2
75cd 79dB
WP
EF201
EF206
EF
EF
P
15cd
15cd
15cd
R
30cd
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
A F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EF101A0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION A ELECTRICAL FIRE ALARM PLAN
AutoCAD SHX Text
AutoCAD SHX Text
RISER RM
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
SECURE
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL RECORDS
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
WORK / SUPPLY
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AUDIOLOGY
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
CHECK-IN
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
VISION / OPTOMETRY
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
EXAM
D1
E1
6 7 8 9 10 11
NEW EGRESS DOOR(S)
FACP
75cd 76dB
75cd 79dB
15cd 79dB
75cd 76dB
30cd 79dB
30cd 79dB
30cd 79dB
15cd 79dB
30cd 79dB
75cd 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
75cd 83dB
75cd 83dB
30cd 79dB
P
P
P
S 76dB
S 76dB
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB 75cd
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
75cd S
76dB S
76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB
75cd
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
79dB
S 76dB 75cd
79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
S 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB75cd
76dB 75cd 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 75cd
75cd
75cd 75cd
75cd 76dB
S
89dB
WP
S89dB
WP
RTAHU-2
RTAHU-3
EF
EF
EF
EF
15cd
R
30cd
30cd
30cd
30cd
15cd
15cd
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- S
EC
TI
O N
B F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
EF101B
A B C
F E D
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION B ELECTRICAL FIRE ALARM PLAN
GENERAL NOTE:
REFER TO SHEET EF001 FOR KEYNOTE INFORMATION.
AutoCAD SHX Text
AutoCAD SHX Text
LAB
AutoCAD SHX Text
AutoCAD SHX Text
IMMUNIZATIONS
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
VITALS
AutoCAD SHX Text
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
DENTAL
AutoCAD SHX Text
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text DIST / Rx
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
SMALL POX
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
BIOHZD
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
AG RECORDS
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
NCM
F1
C
D
E
1611 12 13 14 15
75cd 76dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB75cd
S 76dB
S 76dB75cd
75cd
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
15cd
S 76dB
75cd 76dB
75cd 76dB
S 76dB 30cd
76dB
S 76dB
75cd
S 76dB 75cd75cd
76dB
S 76dB
75cd
30cd 79dB
30cd 79dB
P
P
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 76dB
S 76dB
30cd 79dB
30cd 79dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd 76dB
75cd 76dB
S
89dB WPS89dB
WP S
89dB
WP
S
89dB
WP
S
89dB
WP
EF203
EF204
EF
EF
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- S
EC
TI
O N
C F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
EF101C
A B C
F E D
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION C ELECTRICAL FIRE ALARM PLAN
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
COMPUTER LAB
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
SITE MGR
AutoCAD SHX Text
AutoCAD SHX Text
SRRC OIC
AutoCAD SHX Text
WOMEN
K
H1
G
F
1611 12 13 14 15
FS
TS
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
75cd 76dB
75cd 79dB
75cd 76dB
P
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB75cd
75cd
S 76dB
S 76dB
S 76dB
S 76dB 30cd
79dB
S 76dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB30cd
79dB
S 76dB
S 76dB
75cd 76dB
75cd
S 76dB
75cd 76dB
75cd 76dB
76dB
S 76dB
15cd
30cd 79dB
30cd 79dB
15cd
P
75cd 79dB
75cd 79dB
15cd
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 76dB
75cd 76dB
S 76dB
S
89dB
WP
S
89dB
WP
S
89dB
WP
S
89dB
WP
S
89dB
WP
75cd 79dB
WP
EF203
EF204
EF
EF
15cd
15cd
15cd
15cd 15cd 15cd 15cd 15cd 15cd
15cd 15cd 15cd 15cd 15cd 15cd 15cd 15cd
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- S
EC
TI
O N
D F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
EF101D
A B C
F E D
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION D ELECTRICAL FIRE ALARM PLAN
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SRRC OIC
AutoCAD SHX Text
AutoCAD SHX Text
SRRC XD
AutoCAD SHX Text
AutoCAD SHX Text
CMD STE
AutoCAD SHX Text
AutoCAD SHX Text
SRRC 1SGT
AutoCAD SHX Text
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
SRPC SCHED
AutoCAD SHX Text
AutoCAD SHX Text SRPC MaD
AutoCAD SHX Text
FINAL OUT
AutoCAD SHX Text
AutoCAD SHX Text
CONF
AutoCAD SHX Text
AutoCAD SHX Text
LEGAL
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SHPE
AutoCAD SHX Text
SHPE WAITING
6 7 8 9 10 115.1
P
S S
S
ANN
75cd 76dB
75cd 76dB
15cd 76dB
75cd 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
75cd 76dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
30cd 79dB
76dB
75cd
30cd 79dB
30cd 79dB
30cd 79dB
75cd 83dB
30cd 79dB
30cd 83dB
15cd 83dB
76dB75cd 79dB
75cd 79dB
75cd 76dB
76dB
30cd 79dB
30cd 79dB
15cd 79dB
P
PP
P
P
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB75cd 75cd
S 76dB
S 76dB
S 76dB 75cd
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB75cd
76dB 75cd75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
S 76dB
S 76dB75cd
79dB
S 76dB
S 76dB
S 76dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
S 76dB
S 76dB75cd
79dB
S 76dB
S 76dB
S 76dB
75cd 79dB
75cd 79dB
75cd 79dB
75cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB
75cd 79dB S
76dB
S 76dB
76dB
S 76dB
S 76dB
S 76dB30cd
79dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
76dB S
76dB75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd 76dB
75cd 75cd S
76dB
S 76dB
75cd
30cd 79dB
S 76dB
S 76dB
S 76dB
S 76dB
S
89dB
WP
S
89dB
WP
RTAHU-5 RTAHU-4
EF
EF
EF
EF
15cd
30cd
15cd
15cd
15cd 15cd
15cd
R R
15cd
15cd
15cd
15cd
15cd
EVCS FDCS
K
H1
G
F
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- S
EC
TI
O N
E F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
EF101E
A B C
F E D
0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION E ELECTRICAL FIRE ALARM PLAN
GENERAL NOTE:
REFER TO SHEET EF001 FOR KEYNOTE INFORMATION.
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
ADA-M
AutoCAD SHX Text
AutoCAD SHX Text
ADA-W
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
CONF
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
ELECRICAL
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LOD / NLC
AutoCAD SHX Text
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-A
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-B
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-C
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL FINAL OUT
AutoCAD SHX Text
AutoCAD SHX Text
VAULT
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
CS / FINANCE
AutoCAD SHX Text
AutoCAD SHX Text
AG
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
SRPC SCHED
AutoCAD SHX Text
AutoCAD SHX Text
MED OPS
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
FINAL OUT
AutoCAD SHX Text
AutoCAD SHX Text
CONF
AutoCAD SHX Text
AutoCAD SHX Text
SECUR
AutoCAD SHX Text
AutoCAD SHX Text
VEST
AutoCAD SHX Text
AutoCAD SHX Text
MAIN ENTRY
F2
E1
1 32 4 5
F1
G1
H
K
4.1
L
M
P
P
S S
S
15cd
30cd 76dB
30cd 76dB
76dB
30cd 79dB
30cd 76dB
30cd 79dB
30cd 79dB
75cd 76dB
76dB75cd 76dB
30cd 79dB
30cd 79dB
30cd 76dB
75cd 79dB
76dB
75cd
75cd 83dB
15cd 83dB
75cd 83dB
75cd 79dB
75cd 79dB
P
P PP P
PP
76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
75cd
75cd S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB S
76dB75cd S
76dB75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB 30cd
79dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 76dB
S 76dB
S 76dB
S 76dB
30cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 76dB
30cd 76dB
30cd 76dB
30cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 76dB
30cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
75cd 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
S 76dB
30cd 79dB
30cd 79dB
S 76dB
S 76dB
S 76dB75cd
79dB
75cd
S
89dB
WP
S
89dB
WP
S 89dB
WP
S89dB
WP
S89dB
WP
S 89dB
WP
S
89dB
WP
RTAHU-6
EF201
EF206
EF
EF
15cd
15cd
15cd
15cd
15cd
R
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- S
EC
TI
O N
F F
IR
E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
A B C
F E D
EF101F0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION F ELECTRICAL FIRE ALARM PLAN
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
VEST
AutoCAD SHX Text
AutoCAD SHX Text
VEST
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
ANAM WAITING
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
ANAM TESTING
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDERS
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
MED PROS CHECK-IN
AutoCAD SHX Text
AutoCAD SHX Text
MED PROS
AutoCAD SHX Text
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
BEHAVIORAL HEALTH
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
ELECRICAL
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
VITALS
D1
F1
RTAHU-4
75cd 83dB
75cd 83dB
75cd 83dB
75cd 83dB
75cd 83dB
75cd 83dB
R
1 2
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019
JT
H
JR
D
JT
H
B U
IL
D
IN
G
- M
EZ
ZA
N
IN
E
FI
R E
A
LA
R M
PL
A
N S
- E
LE
C
TR
IC
A
L
A B C
F E D
EF102A0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - MEZZANINE ELECTRICAL FIRE ALARM PLAN
D1
E1
WP WP
X3
X1
X3
M - 14'
B B
B
BE
BE
B
B
BE
BE
B2E
B2E
B2E B2E
B2E
B
OS
OS
OS OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS OS
OS OS OS OS
OS
OS OS
OS
OS
OS
OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OSOSOS
OS OSOS OSOSOS
OS
OS
OS
OS
OS
OS
OS
D
D
D
3,D
D D
3,D
D
D
4,D
D D
D
D
D
3,D
3,D
B BE
BE
B
A1E
A1E
A1E
M - 14'
A1E
A1E
F2 F2 F2 F2
L4E
L4E L4
L4L4E
F
FE
F
FE
F F
F F
F
FE
F
FE
F F
F F
JE
F1
F1
F1E
F1
F1 F1
F1E
F1
FE F FE F
F FE F
FE
J
JE
J
JE
A1E
JE
J
JE
A1E JE J JE J JE J JE J
A2 A2
A2 A2
A2 A2
A2 A2
FF
FEF
FF
FF
FE
F
FF
F
FE
F
FE
F
F
F
F
F
F
F
F
FE
FE
F
F1E F1
F1 F1
F2
F2
F2
F2
F2
F2
F2
F2
L4E
L4
L4E
L4
L4E
L4
L4 L4E
L4
L4E
L4E L4E
L4
L4E
F2 F2
F FE F
FE F FE
F1E
F1
F1
F1
F1
F1
F1E F1
F1 F1
F1
F1E
F1
F1
F1
F1
F2 F2
F2 F2
F1E
F1
J JE J JE J
L4E
L4
F2
F2
F2F2F2F2F2F2F2F2F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2F2F2F2F2F2F2F2F2 L4
L4E
L4
L4E L4
L4E
L4E L4
D
3,D
OS
F F
OS
L4
O S
O S
L4
L4
L4EL4EL4E L4L4L4
L4E L4 L4E
L4EL4E
L4L4L4
X1
X1
X1X1
X1
X3 X3
X3 X3
X1
N
N
N
SH1B-5 VIA
(RPH1B-2)
X1
X1
SH1B-5 VIA
(RPH1B-2)
SH1B-5 VIA
(RPH1B-2)
L4 L4
SH1B-5 VIA
(RPH1B-2) SH1B-8
H6-7 VIA
(RP6A-7)
H6-8 VIA
(RP6A-8)
EL101A
EL101F
D
D
D
WP
WP
WPWP
WP
WP
WP
WP
SH1B-1 VIA
(RPH1B-1)
1 32 4 5
EL
1A
EL
1B
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
A L
IG
H
TI
N
G P
LA
N
EL
EC
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EL101A0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION A ELECTRICAL LIGHTING PLAN
GENERAL NOTES:
1. REFER TO DETAIL C1 ON SHEET E505 FOR
LIGHTING CONTROL STRATEGIES, AND SHEET
E-003 FOR KEYNOTE INFORMATION.
2. FOR EXISTING LIGHT FIXTURES REMAINING,
CONTRACTOR TO REMOVE LIGHT FIXTURE
LENSES, WASH AND REPLACE THEM ALONG
WITH REPLACING EXISTING LAMPS/TUBES
WITH NEW.
3. CONDUITS FOR EXTERIOR LIGHTING TO BE
KEPT WITHIN BUILDING, NOT ROUTED ON
FACE OF BUILDING. PROVIDE WALL
PENETRATION BEHIND FIXTURE AT
LOCATIONS SHOWN.
4. RE-USE EXISTING PHOTOCELL, ROUTE NEW
CONDUIT 2'-0" BELOW ROOF LINE TO WALL
PENETRATION THEN ROUTE AS NECESSARY
TO CONTROL EXTERIOR LIGHTING. FILL WALL
PENETRATION AS NECESSARY TO MAINTAIN
FIRE RATING.
AutoCAD SHX Text
AutoCAD SHX Text
RISER RM
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
SECURE
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL RECORDS
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
WORK / SUPPLY
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
AUDIOLOGY
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
CHECK-IN
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
VISION / OPTOMETRY
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L3
AutoCAD SHX Text L4
AutoCAD SHX Text L3
AutoCAD SHX Text L4
AutoCAD SHX Text L3
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L7
AutoCAD SHX Text L8
L10
D1
E1
NEW EGRESS DOOR(S)
WP
X3 X3
X1
BE
BE
B2E
B2E
B
B
B
B B
B B
M - 14'M - 14'
OS OS OS
OS
OS
OS
OS OS OS
OS OS OS
OS
OS
OS OS
OS OS
OS
OS
OS
O S
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS OS
OS OS
OS
OS
OS
OS OS OS
OSOS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
3,D3,D
D 3,D
3,D
3,D
3,D
D
DD
3,D
D D
D
D
3,D
OS
3,D
3,D
NOT IN SCOPE
OF WORK
BE
BB
ELECTRICAL
ROOM
MECHANICAL &
ELECTRICAL
ROOM
BE
BB
BE
BE
NEW EGRESS DOOR(S)
WP WP
BE
B
BE
BE
B
BE
A1E
A1E
A1E
A1E
A1E A1E
A1E
A1E
A1E
F1
F1
F1
F1
F1
F1 F1 F1
F1 F1
F1 F1 F1
F1E F1 F1E
F1 F1
F2 F2
F2 F2
F1 F1E F1
F1
F1
F1
F1
F1E
F1
F1
F1
F1
F1
F1E
F1
F1
F1
F1
F1
F2
F2
F1EF1
F1E
F FE F
FE
FE F FE F
3,D
F
F
F
FE
F
F
F
F
F
FE F
FE
F
F
FE
F
F
F
F
F
FE
F
F
F
F
F
F
FE
FFE
F1E
F1
FE
F
FE
F
F F F
F
FE
F
FE F
F F F F
B2E B2E B2E
F1E
F1
F1
F1
F1E
F1
JE J
A1E
JE J JE
A1E A1E
J JE JE J JE J
JE
J
JE
J
JE
JE
J
JE
F
F
FE
F
F
F
FE
F
F
F
FE
F
F2F2F2F2
F2
F2
F2
F2
F2
F2
F2
F2
L4
L4E
L4E
L4 L4E L4
F2F2F2F2
F2F2F2 F2
F2F2F2F2
F2 F2
L4E
L4E
L4 L4E
L4
L4 L4E L4
L4
L4 L4 L4 L4E
L4E L4
F2
F2
F2
F2F2
F2
F2 F2
F2 F2 F2 F2
F2 F2
L4E
L4E
L4
L4E
L4E
L4E
L4E L4
L4E
L4
L4E
L4
L4E
F
F L4E
L4
L4
L4EL4
L4L4E
L4L4
L4L4E
L4L4L4EL4
L4E
L4
L4E
F2
F2F2
F2F2
F2
F2
F2
F2 F2
B
L4 F2
F2F2
F2F2
F2
F2
F2F2
L4E
4,D
OS
L4
3 3
3 3
F1 3,D
3,D
F
4,D
L4
L4E L4
OS
L4E
X3
X1 X1
X1
X1
X3
X1
X1
X1 X1
X1 X3
X1
X1
X1
X2
X2
X1X1
X2
X2 X2
SH1A-1
VIA
(RPH1A-1)
SH1A-6
N X1
X1
SH1A-4 VIA
(RPH1A-4) SH1A-5
H2-1 VIA
(RP2A-1)
H2-3 VIA
(RP2A-2)
SH1B-5 VIA
B
BE
OS
SH1A-9
SH1A-10
B
BOS
H2-5 VIA
(RP2A-3)
H2-2 VIA
(RP2A-4)H2-4 VIA
(RP2A-5)
ME - 4'
ME - 4'
ME - 4'
ME - 4'
SH1A-4 VIA
(RPH1A-4)
SH1A-4 VIA
(RPH1A-4)
6 7 8 9 10 11
EL
1A
EL
1B
EL
1B
EL
1C
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
B L
IG
H
TI
N
G P
LA
N
EL
EC
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EL101B0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION B ELECTRICAL LIGHTING PLAN
GENERAL NOTES:
1. REFER TO DETAIL C1 ON SHEET E505 FOR
LIGHTING CONTROL STRATEGIES, AND SHEET
E-003 FOR KEYNOTE INFORMATION.
2. FOR EXISTING LIGHT FIXTURES REMAINING,
CONTRACTOR TO REMOVE LIGHT FIXTURE
LENSES, WASH AND REPLACE THEM ALONG
WITH REPLACING EXISTING LAMPS/TUBES
WITH NEW.
3. CONDUITS FOR EXTERIOR LIGHTING TO BE
KEPT WITHIN BUILDING, NOT ROUTED ON
FACE OF BUILDING. PROVIDE WALL
PENETRATION BEHIND FIXTURE AT
LOCATIONS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
LAB
AutoCAD SHX Text
AutoCAD SHX Text
IMMUNIZATIONS
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
VITALS
AutoCAD SHX Text
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
DENTAL
AutoCAD SHX Text
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text DIST / Rx
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
SMALL POX
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
BIOHZD
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
AG RECORDS
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
NCM
AutoCAD SHX Text
AutoCAD SHX Text
CS / FINANCE
AutoCAD SHX Text
AG
AutoCAD SHX Text L8
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L4
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L5
AutoCAD SHX Text L5
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
L7
1611 12 13 14 15
WP
X1
B
M - 22'
M - 22'
OS
OS
OS
OS
OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OSOS
OS
OS
OS OS
OS
OS OS
D
D
D
D
NOT IN SCOPE OF WORK
A1E
ME - 4'
ME - 4'
F1E
F1
F1
F1
F1E
F1
F1
F1
F1E
F1
F1
A1
JE
J JE
JE
J
JE
JE
JE
F1 F1
F1
F2 F2 F2
F2 F2
F2
F2F2
L4
L4E
L4E
L4 L4E
F
F
F2
F2
F2
L4E
L4
A1E
X2
X1
X3
SH1A-3 VIA
(RPH1A-3)
X1
EL
1B
EL
1C
ME - 4'ME - 4'
ME - 4'ME - 4'
WP WPWP
EL101C
EL101D
A
B
C
D
E
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
C L
IG
H
TI
N
G P
LA
N
EL
EC
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EL101C0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION C ELECTRICAL LIGHTING PLAN
GENERAL NOTES:
1. REFER TO DETAIL C1 ON SHEET E505 FOR
LIGHTING CONTROL STRATEGIES, AND SHEET
E-003 FOR KEYNOTE INFORMATION.
2. FOR EXISTING LIGHT FIXTURES REMAINING,
CONTRACTOR TO REMOVE LIGHT FIXTURE
LENSES, WASH AND REPLACE THEM ALONG
WITH REPLACING EXISTING LAMPS/TUBES
WITH NEW.
3. CONDUITS FOR EXTERIOR LIGHTING TO BE
KEPT WITHIN BUILDING, NOT ROUTED ON
FACE OF BUILDING. PROVIDE WALL
PENETRATION BEHIND FIXTURE AT
LOCATIONS SHOWN.
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
COMPUTER LAB
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text S1
AutoCAD SHX Text
AutoCAD SHX Text
SITE MGR
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L5
AutoCAD SHX Text L5
AutoCAD SHX Text L7
AutoCAD SHX Text L7
1611 12 13 14 15
X1
X1
X1
X3
BE
BE
H
O S
OSOSOS OS
OS OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OS OS
OS OS
OSOS
OS
OS
OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
D
OS
D
OS
3,D 3,D
OS
OS
D
D
OS
OS
D D D D D D D D
D D D D D D 3,D
3,D
D
OS D
DD
D
D
D
D
D
D
OS
B2E B2E NOT IN SCOPE OF WORK
A1E
A1E
A1E
ME - 4'
A1E A1E
A1E
A1E
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2
A2
A2 A2
A2
A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
A2 A2
F FE
FE
F
F
FE
JE J JE J
JE
J JE
J
JE
J
JE
JE
J
JE
JE
A1E
J JE J
L6 L6E
OS
F1
F1E
F1
F1
B
F2
F2
F2
F2
F2
F2
F2
L4E
L4E
F1
F1
F1
F1E
F1
F1
F1E
F1
F1
F1
F1E
F1
F1E F1
L4
L4E
L4 L4EL4E
F2
L4L4E
L4E
F2
F2 F2
F2
F1
F2
F2
F2 F2
L4E
L4
L4
L4E
OS
L6
X1
X3
A2A2
SH1A-1
VIA
(RPH1A-1)
H3-2 VIA
(RP3A-2)
A3E
SH1A-3 VIA
(RPH1A-3)
H3-3 VIA
(RP3A-3)
SH1A-2 VIA
(RPH1A-2)
H3-1 VIA
(RP3A-1)
OS OS OS OS
OS OS OSOS OS
EL
1E
EL
1D
ME - 4'ME - 4'
JJJJ
J J J J
J J
SLTR3-13SLTR3-15
OS
SLTR3-17
TYP.
SLTR3-19SLTR3-21
EXISTING LIGHTING CIRCUITRY
AND CONTROLS TO REMAIN.
EL101C
EL101D
H3-7 VIA
(RP3A-7)
K
H1
G
F
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
D L
IG
H
TI
N
G P
LA
N
EL
EC
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EL101D0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION D ELECTRICAL LIGHTING PLAN
GENERAL NOTES:
1. REFER TO DETAIL C1 ON SHEET E505 FOR
LIGHTING CONTROL STRATEGIES, AND SHEET
E-003 FOR KEYNOTE INFORMATION.
2. FOR EXISTING LIGHT FIXTURES REMAINING,
CONTRACTOR TO REMOVE LIGHT FIXTURE
LENSES, WASH AND REPLACE THEM ALONG
WITH REPLACING EXISTING LAMPS/TUBES
WITH NEW.
3. CONDUITS FOR EXTERIOR LIGHTING TO BE
KEPT WITHIN BUILDING, NOT ROUTED ON
FACE OF BUILDING. PROVIDE WALL
PENETRATION BEHIND FIXTURE AT
LOCATIONS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SCREENING
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SRRC OIC
AutoCAD SHX Text
AutoCAD SHX Text
SRRC XD
AutoCAD SHX Text
AutoCAD SHX Text
CMD STE
AutoCAD SHX Text
AutoCAD SHX Text
SRRC 1SGT
AutoCAD SHX Text
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
BRK RM
AutoCAD SHX Text
AutoCAD SHX Text
SRPC SCHED
AutoCAD SHX Text
AutoCAD SHX Text SRPC MaD
AutoCAD SHX Text
FINAL OUT
AutoCAD SHX Text
AutoCAD SHX Text
CONF
AutoCAD SHX Text
AutoCAD SHX Text
LEGAL
AutoCAD SHX Text
AutoCAD SHX Text
EXAM
AutoCAD SHX Text
AutoCAD SHX Text
SHPE
AutoCAD SHX Text
AutoCAD SHX Text
SHPE WAITING
AutoCAD SHX Text L8
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L6
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L5
AutoCAD SHX Text L6
AutoCAD SHX Text L2
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L6
AutoCAD SHX Text L4
AutoCAD SHX Text L6
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L4
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
AutoCAD SHX Text L7
L9
6 7 8 9 10 115.1
X3 X3
X1
X1
X1
X1
X3
X3
X3
A1 A1
A1 A1E
A1E
A1A1 A1
A1 A1E A1E
A1 A1E
A1E
A1E
A1E
B
B
M - 32'M - 32'
BE BE
B2E B2E B2E
B2E
BE
BE
B2E B2E
B2E
B
OS OS OS OS OS OS
OS
OS
OS
OS
OS
OS OS OS OS OS OS OS OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS
OS
OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS OS OS
OS
OS OSOS
OS OS
OS
OS
OS OS OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OSOS
OS
OS OS
OS
D
D
OS
D
D
D
LC
LC
LC
LC
LCLC
3,D3,D
D
OS
D 3,D
3,D
3,DD
OSD
B2
F3 F3 F3 F3
F3
F3
F3
F3
F3
F3
F3
F3
F3
OS
OSOS
A1E A1E A1E
A1E A1E
A1E A1E A1E A1E
A1E
A1E
A1E
A1E
A1E
A1E A1E
A1E
A1E A1E
D DE D
A1E
JE J JE J JE J JE J JE JE
J
JE
J
JE
JE
J
JE
J
A1E
A1E
A1E
JE J JE J JE J JE J JE JE J
JE
J
F F F
F F F
L8E L12 L8E
L8 L12E L8
L8E L12 L8E
L8 L12E L8
L8E L12 L8E
L8 L12E L8
L8E L12 L8E
L8 L12E L8 L8E L8
L8 L8
L8
L8E
L8E
L8
L8 L8
L8 L8E
L8E L8
L8 L8 L8 L8E L8
L8E L8 L8E
L8 L8E L8
L8E L8 L8E
L8 L8E L8
L8E L8 L8E
L8 L8E L8
L8E L8 L8E
L6
OS
L6E
OSFE
F1
F1E
F1
F1
F1
F1E
F1
F1
B
B
F2
F2 F2
F2 F2
L4E
L4E
L4
L4E
L4E
F1
F1
F2 F2 F2
F2
F2 F2 F2
F2
F2 F2 F2 F2 F2
L4
L4E
L4
L4E
L4
L4 L4E L4
L4E L4 L4E
F2F2F2F2
F2F2F2F2
F2 F2
F2
L4EL4E
L4 L4E
L4
L4 L4E
L4L4
L4 L4 L4E
L4E L4
F1 F1
F1 F1
F
F
F
FE
F
FE
F
F
F
FE
F
FE
F
F
H
L4L4L4EL4L4E
L4
L4E
F2 F2
F2 F2
F2 F2
F2 F2 F2
F2
F2
F2 F2
F2
L4
L4 L4E
F
FE
L4E
L4
F2
F2
D
3,D 3,D3,D
3,D3,D
3,D
3,D
OS
A1E
OS
OS
OS OS
L6
X1
X1
X3
X1
X1
X1
X3
X3 X1
X1
X1
X1
X2
SH1A-3
VIA
(RPH1A-3)
B2E B2E
SH1B-9
SH1A-8H3-5 VIA
(RP3A-5)
H3-4 VIA
(RP3A-6)
H3-6 VIA
(RP3A-7)
SH1B-5 VIA
(RPH1B-2)
L8E L8E
L8L8
L8L8
L8 L8
L8E L8E
L8 L8
L8
L8E
L8E
L8E
A1
SH1A-7
EL
1F
EL
1E
EL
1E
EL
1D
ME - 4'
ME - 4'
ME - 4'
ME - 4'
ME - 4'
WPSH1A-1
VIA
(RPH1A-1)
WP
WP SH1A-1
VIA
(RPH1A-1)
ME - 4'
ME - 4'
ME - 4'
ME - 4'
ME - 4'
E1
F1
G1
H
K
L
M
A
FO
R
T
BL
IS
S, T
EX
AS
M
AR
K D
AT
E:
D
ES
C R
IP
TI
O N
D
ES
IG
N
B Y:
SHEET ID
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
SI
ZE
AN
SI
_D
IS
SU
E D
AT
E:
FI
LE
N
AM
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
R
EN
O
VA
TI
O
N O
F
BU
IL
D
IN
G
S
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
FO
R
T W
O R
TH
D
IS
TR
IC
T
TA
YL
O R
S
TR
EE
T, R O
O M
A1
FO
R T
W O
R
TH
, T X
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SU
BM
IT
TE
D B
Y:
IC
E- D
EC
J
V
W
G
-1 9-
B-
US Army Corps of Engineers
/2
4/
TB
D
AE
C
O M
KA
TY
F
R
EE
W
AY
S U
IT
E
H O
U
ST
O N
, T X
JV
0-
B1717
CORRECTED FINAL SUBMITTAL 24 JULY 2019
PLAN
NORTH
07/24/2019 B U
IL
D
IN
G
- S
EC
TI
O N
E L
IG
H
TI
N
G P
LA
N
EL
EC
TR
IC
A
L
JT
H
JR
D
JT
H
A B C
F E D
EL101E0 8' 16' 24'2' 4'
SCALE: 1/8" = 1'-0"
Scale: 1/8"=1'-0"A1 BUILDING 1717 - SECTION E ELECTRICAL LIGHTING PLAN
GENERAL NOTES:
1. REFER TO DETAIL C1 ON SHEET E505 FOR
LIGHTING CONTROL STRATEGIES, AND SHEET
E-003 FOR KEYNOTE INFORMATION.
2. FOR EXISTING LIGHT FIXTURES REMAINING,
CONTRACTOR TO REMOVE LIGHT FIXTURE
LENSES, WASH AND REPLACE THEM ALONG
WITH REPLACING EXISTING LAMPS/TUBES
WITH NEW.
3. CONDUITS FOR EXTERIOR LIGHTING TO BE
KEPT WITHIN BUILDING, NOT ROUTED ON
FACE OF BUILDING. PROVIDE WALL
PENETRATION BEHIND FIXTURE AT
LOCATIONS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
ADA-M
AutoCAD SHX Text
AutoCAD SHX Text
ADA-W
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
CONF
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
WRK RM
AutoCAD SHX Text
AutoCAD SHX Text
ELECRICAL
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LOD / NLC
AutoCAD SHX Text
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
TR
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-A
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-B
AutoCAD SHX Text
AutoCAD SHX Text
BRFG-C
AutoCAD SHX Text
AutoCAD SHX Text
MEDICAL FINAL OUT
AutoCAD SHX Text
AutoCAD SHX Text
VAULT
AutoCAD SHX Text
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
AutoCAD SHX Text
CS / FINANCE
AutoCAD SHX Text
AutoCAD SHX Text
AG
AutoCAD SHX Text
AutoCAD SHX Text
CORR
AutoCAD SHX Text
AutoCAD SHX Text
SRPC SCHED
AutoCAD SHX Text
AutoCAD SHX Text
MED OPS
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.