15' TYP.

EXISTING GRADE

CONCRETE ANCHORS

CAST IN PLACE

6" TYP.

CONCRETE ANCHORS

CAST IN PLACE

ON GRADE

CONDUITS LAYING

BLOCK FROM ADHERING

TO KEEP CONCRETE

MATERIAL ON GROUND

PUT PLASTIC OR OTHER

3"

PLASTIC

SET ON

(TYP.)

CLASSROOM UNITS

PVC CONDUITS TO

GROUND LUG/BOLT

BLOCKS (TYP.)

TAP TERMINAL

GRS CONDUIT

INCOMING

/9 /2

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

M A

U R

E -5

X X

X .d g n

N .T .S

A N

S I

D

E L E

C T

R

IC

A L D

E T

A

IL

S

E-502

INCHES SPACE BETWEEN.

3. CONDUIT SPACING SHALL BE TO INDUSTRY PRACTICE AND NOT CLOSER THAN 2

ON PIPING.

WATER/WASTE PIPING. BLOCK UP CONDUITS WHERE REQUIRED TO AVOID LOAD

2. GENERALLY CONDUITS WILL BE RUN ABOVE GROUND AND INSTALLED ABOVE

FACILITATE WATER AND WASTER WATER PIPING.

1. CONDUITS CAN BE INSTALLED UNDERGROUND OR ABOVE GROUND TO

NOTES:

4 TAMP CONCRETE SO THAT IT IS WELL CONSOLIDATED.

SHEETING ON THE GROUND TO PREVENT ADHERING.

THE CONCRETE CONDUIT ANCHOR SHALL BE PLACED OVER PLASTIC OR OTHER

CONDUITS BY 2" AND BE 6" THICK.

CONCRETE CONDUIT ANCHOR TO EXTEND 3" PAST CONDUIT SIDE AND COVER

CONCRETE CONDUIT ANCHORS SHALL GENERALL BE PLACED EVERY 15 FT.

KEYNOTES:

N.T.S.

DETAIL

CONDUIT ANCHOR INSTALLATION

SCALE:

N.T.S.

DETAIL

SWITCHGEAR SETTING

SCALE:

N

L1

L2

UL LISTED CONNECTOR.

GROUND LUG SHALL BOND ENCLOSURE AND CONDUCTOR GROUND WIRES.

TWO 1/16" HOLES IN BOTTOM TO DRAIN.

SET TAP BOX ABOVE GROUND AND LEVEL GRAVEL SO THAT IT CAN DRAIN. DRILL

CONDUCTORS. UL LISTED 90° DC WITH INSULATING COVERS.

TAP TERMINAL BLOCKS SHALL BE CONFIGURED FOR INCOMING AND OUTGOING

FOR ALL CONDUIT ENTRANCES AND WIRE BENDING SPACE. UL LISTED.

TAP BOX ENCLOSURE SHALL BE TYPE 4 16 GA. CRS MINIMUM. SIZE PER CODE

KEYNOTES:

APPROX. 24" X 24"

S H

E E

T O

F

M A

U R

P R

F

D B

S C

R

IT

IC

A L P

U B

L

IC

F

A C

IL

IT

Y

L

IT

T L E C

Y P

R E

S S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

ID

Sheet

File details come from the government source that posted it. Updated .