MAUR_E-101XXX.pdf
PDF 2 MB Posted
- Attached to
- Mauriceville Temporary Classroom Project
- Solicitation number
- W9126G18Q0006
About this file
Plan Sheet E-101
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MAUR_E-101XXX.pdf | ||
| 18Q00060004.pdf | ||
| Price_Schedule__LCM.xlsx | XLSX spreadsheet | |
| MAUR_E-502XXX.pdf | ||
| 18Q00060002.pdf | ||
| MAUR_C-101XXX.pdf | ||
| MAUR_CD101XXX.pdf | ||
| MAUR_E-501XXX.pdf | ||
| MAUR_E-101XXX.pdf | ||
| 18Q00060001.pdf | ||
| MAUR_FullSize_4Nov2017-FINAL.pdf | ||
| MAUR_HalfSize_4Nov2017-FINAL.pdf | ||
| W9126G18Q0006.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
SERVICE
OVERHEAD ELECTRICAL
CONNECT TO EXISTING
(TYP.)
CLASSROOM UNITS
TAP BOX - 1 PER 3
ELECTRICAL
POWER POLE
EXISTING
CLASSROOM UNITS (TYP.)
TAP BOX - 1 PER 2 OR 3
ELECTRICAL
ACCESS
MAINTAIN VEHICLE
HEIGHT TO
TO SUFFICIENT
TO BE INSSTALLED
OVERHEAD LINE
SERVICE
OVERHEAD ELECTRICAL
CONNECT TO EXISTING
POWER POLE
PROPOSED
TRANSFORMER AS SHOWN
CONDUIT TO
EXTEND PRIMARY
CROSSING DRIVE
ELECTRICAL CONDUITS
PROTECTION SYSTEM FOR
PROVIDE TRAFFIC-RATED
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
ID
Sheet
/9 /2
A N
S I
D
P R
F
D B
S
E-101
M A
U R
E -1
X X
X .d g n
SHEET KEYNOTES
80'0 40'
N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
M A
U R
C R
IT
IC
A L P
U B
L
IC
F
A C
IL
IT
Y
L
IT
T L E C
Y P
R E
S S
M A
U R
IC
E V
IL
L E T
X
F E
M A D
R -4
-T
X G
A L
V E
S T
O N D
IS
T R
IC
T
G A
L V
E S
T O
N T
X
E L E
C T
R
IC
U
T
IL
IT
Y P
L A
N
LEGEND
ELECTRICAL CONDUIT
PRIMARY ELEC. CONDUIT
RELOCATED (BURIED) ELEC. LINE
OVERHEAD ELECTRIC (EXISTING)
OVERHEAD ELECTRIC (PROPOSED)
ELECTRICAL NOTES
TB 8
TB 6 TB 7
TB 5
TB 3
TB 4
TB 2
TB 1
TB 9
TB 10
TB 11
SP 1
SP 2
SP 4
TRANSFORMER AND SERVICE PANEL
TAP BOX
SP 3
TO CONSTRUCTION FOR UTILITY LOCATES.
CONSTRUCTION. CONTRACTOR SHALL CALL TEXAS811 PRIOR
FOR VERIFYING ALL UTILITIES PRIOR TO BEGINNING
UTILITIES WITHIN THE PROJECT AREA AND IS RESPONSIBLE
3. THE CONTRACTOR SHALL BE AWARE OF THE EXISTING
SPECIFIC LOCATIONS.
ENTERGY, (409-679-6225) AND CONTRACTING OFFICER ON
SHOWN IN APPROXIMATE LOCATIONS. COORDINATE WITH
2. THE POLES AND ASSOCIATED 400 AMP SERVICES ARE
COORDINATED.
WILL CONTINUE TO BE REQUIRED. OUTAGES WILL NEED TO BE
1. THE EXISTING SCHOOL ELECTRICAL SERVICE IS IN USE. AND
PRIMARY LINES.
ENTERGY WILL PROVIDE AND INSTALL OVERHEAD
EXISTING U.G. PRIMARY CABLES AND DUCT BANK.
File details come from the government source that posted it. Updated .