AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This amendment revises Section 002211, and adds attachments to Sections 087100 and 12 50 00
1. CONTRACT ID CODE PAGE OF PAGES
J 1 13
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 13-Jul-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9126G-16-R-0081
X 9B. DATED (SEE ITEM 11)
01-Jul-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
14-Jul-2016
CODE
US ARMY ENGINEER DISTRICT, FORT WORTH
ATTN: CESWF-CT
819 TAYLOR ST, ROOM 2A17
FORT WORTH TX 76102-0300
W9126G 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9126G-16-R-0081
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION 00 22 11 - PROPOSAL SUBMISSION REQUIREMENTS, EVALUATION CRITERIA, AND BASIS
OF AWARD ONE STEP - BEST VALUE, DESIGN-BUILD (SINGLE AWARD)
The following have been modified:
SECTION 002211 Proposal Submission Requirements, Evaluation Criteria, and Basis of Award
PART I – GENERAL INFORMATION
As this is a competitive negotiation acquisition, there is no public bid opening and no information will be given out as to the number of offerors or the results of the competition until all awards are made.
Oral explanations or instructions are not binding. Any information given to an offeror which impacts the solicitation and/or offer will be given in the form of a written amendment to the solicitation.
PART II -- PROPOSAL PREPARATION
1. PROPOSAL SUBMISSION REQUIREMENTS AND INSTRUCTIONS
a. REQUIREMENT FOR SEPARATE PRICE AND TECHNICAL PROPOSALS.
(1) Each offeror must submit both a Price Proposal and a Technical Proposal. The Price Proposal and the Technical Proposal must be submitted as separate files. Ensure each separate file is clearly marked to indicate its contents and the identity of the offeror.
(2) Both the Price Proposal and the Technical Proposal must be received by the closing date and time set for receipt of proposals.
(3) No dollar amounts from the Price Proposal are to be included in the Technical Proposal.
(4) All information intended to be evaluated as part of the Technical Proposal must be submitted as part of the Technical Proposal. Do not merely cross-reference similar material in the Price Proposal, or vice versa. Also, do not include links to websites in lieu of incorporating information into your proposal.
(5) Do not include exceptions to the terms and conditions of the solicitation in either the technical or price proposal. Should the offer include any standard company terms and conditions that conflict with the terms and conditions of the solicitation, the offer may be determined "unacceptable" and thus ineligible for award. Should the offeror have any questions related to specific terms and conditions, these shall be resolved prior to submission of the offer.
b. DISCUSSIONS: The Government intends to evaluate proposals and award a task order without discussions with offerors, in accordance with FAR 52.215-1, Instructions to Offerors—Competitive Acquisitions, however the Government reserves the right to conduct discussions if the Contracting Officer determines them to be necessary.
c. GENERAL INSTRUCTIONS
(1) All pages must be numbered.
(2) Submit only the information/documents specifically required. Do not submit excess information, to include audio-visual materials, electronic media, etc.
(3) Do not use a font size smaller than 10, an unusual font style such as script, or condensed print for any submission. All page margins must be at least 1 inch wide, but may include headers and footers.
(4) The proposals must be organized by the TABs indicated in this section.
(5) “Confidential” projects cannot be submitted to demonstrate capability unless all of the information required for evaluation as specified herein can be provided to the Government as part of the Offeror’s technical proposal. Offerors that include in their proposals information that they do not want disclosed to the public for any purpose, or used by the Government except for evaluation purposes, must be clearly marked in accordance with the instructions at FAR 52.215-1, “Instructions to Offerors— Competitive Acquisition”, paragraph (e), “Restriction on disclosure and use of data”.
(6) In the case of an Offeror that is part of a large, multi-segmented business concern, provide information directly pertaining to the specific segment of the business concern (i.e., the division, group, unit, etc.) that will perform work under the prospective contract.
(7) For submissions with page limitations, the pages furnished for organizational purposes only, such as a “Table of Contents” or divider tabs, are not included in the page limitation.
d. INSTRUCTIONS FOR THE PRICE PROPOSAL AND MISC DOCUMENTS
Price Proposal: The Price Proposal file shall be appropriately titled as such. It shall consist of a cover letter and the CLIN Schedule (from Section 001100), completed in its entirety
Acknowledgement Sheet. A completed Acknowledgement Sheet (Attachment 1) shall be completed by the offeror and duly executed with an original signature by an official authorized to bind the company in accordance with instructions at FAR 4.102.
Bid Guarantee/bond. Submit a scanned copy of the completed Bid Bond, Standard Form 24, with the proposal. Mail the original bond to the Contracting Officer post marked no later than the date the proposals are due.
Completed Representations and Certifications from Section 004500:
52.204-8 (if any updates to SAM apply)
52.209-7
e. INSTRUCTIONS FOR THE TECHNICAL PROPOSAL
The Technical Proposal will be appropriately labeled as follows:
Factor 1, EXPERIENCE Factor 2, TECHNICAL APPROACH Factor 3, PAST PERFORMANCE
Page Limitations. The following page limitations are established for each factor described above:
Factor 1, Experience - Limited to 5 pages Factor 2: Technical Approach – Limited to 5 pages Factor 3, Past Performance - No page limitation
FACTOR 1, EXPERIENCE: TECHNICAL NARRATIVE ON PROJECTS OF SIMILAR
SCOPE, MAGNITUDE, AND COMPLEXITY
The Offeror shall submit a completed Experience Information Form (Attachment 2) for at least two and no more than five projects of similar scope, magnitude and complexity as the RFP requirement it and/or its proposed team (i.e., predecessor companies, key personnel who have relevant experience or subcontractors that will perform major or critical aspects of the requirement) has/have successfully completed within the past five years.
The Experience Information Form must include the Offeror’s role in the project (i.e., as a prime or a subcontractor), and be fully completed to be considered for this factor.
The specific elements that must be demonstrated within the combined experience demonstrated to be considered of similar scope, magnitude and complexity as the RFP requirement are:
- Contract/TO/PO Dollar Value at least $6,000,000
- Experience with vertical construction of similar size and scope with predominance of management and responsibility for the project.
- Experience working on a DOD installation
- Experience working on a project ensuring continuity of adjacent existing operations throughout construction.
- Experience managing the transfer of operations to new facility without loss of function.
- Experience working with the USACE including Safety Manual EM385-1-1, 3 phase inspection process, Quality Control, Scheduling
The Offeror must explain why it believes the projects are similar in scope, magnitude and complexity to the RFP requirement.
If experience of predecessor companies, key personnel, or major subcontractors is submitted to qualify for this factor the offeror must include a statement indicating their role in the project being used as experience as well as the percentage of work they will be performing in the proposed project. The Government will not consider the experience provided if it is determined the role in either project is not significant.
Failure to demonstrate the required experience or provide all required information will result in an “UNACCEPTABLE” rating and possible elimination from further consideration for award.
FACTOR 2, TECHNICAL APPROACH: TECHNICAL NARRATIVE ON TECHNICAL
APPROACH, METHODS AND PROCEDURES AND SCHEDULE
The Offeror must provide a narrative that includes, at a minimum, discussion of the proposed sequence of work, mandatory phasing, testing and balancing, and interim and final acceptance.
Offers must include a Gantt chart reflecting the major construction activities with the completion period from the applicable contract Notice to Proceed (NTP). The schedule must be graphically presented, and must be on a maximum paper size of 11”x17”. The schedule must reflect the major construction milestones and the sequence of work required for this project. The schedule must indicate start/finish dates of events and durations. A detailed network analysis is not required as a proposal submittal item.
The narrative must include:
- The Offeror’s technical understanding of the work requirements
- The Offeror’s commitment to accomplish all the work in accordance with the solicitation requirements and schedule
- The Offeror’s approach, methodology and plan for customer service
- The Offeror’s Quality Control procedures
- The Offeror’s construction safety protocols and procedures
- The workability of the Offeror’s approach as well as the technical feasibility to successfully perform on schedule
Offerors are cautioned that if they do not meet the project duration shown in Section 00 73 00 Paragraph 52.211-10, Commencement, execution and Completion of Work of this Request for Proposal their response for Evaluation Factor 2 will be rated Unacceptable. Schedules showing Government submittal review durations to be shorter than are contractually mandated will be rated Unacceptable.
FACTOR 3, PAST PERFORMANCE: For each project submitted under the Experience factor that does not have an evaluation in the Past Performance Information Retrieval System (PPIRS), which includes evaluations submitted in ACASS, CCASS, and CPARS, Offerors shall forward a copy of the Past Performance Evaluation Questionnaire (PPQ) included at Attachment 3 to the points of contact responsible for monitoring performance under those contracts for completion.
Completed PPQs shall be submitted by the offeror with the proposal. If unable to obtain a completed PPQ for a project timely the Offeror shall complete and submit with the proposal the first page of the PPQ, which will provide contract and client information for the respective project(s).
If any negative past performance information is received to which the Offeror has not previously had an opportunity to respond, the Offeror will be given an opportunity to provide rebuttal.
If a PPQ is received on a project that has an evaluation in PPIRS, the PPQ will not be considered.
f. DIRECTIONS FOR SUBMITTING PROPOSALS
Securely submit your proposal at the AMRDEC SAFE website, https://safe.amrdec.army.mil/SAFE2/
1) At the AMRDEC SAFE website select the link: “I do not have a CAC or this machine is not configured to read my CAC and I would like to access SAFE as a Guest User”.
2) Complete the required information. At “Files:” upload your proposal documents.
3) In the “Recipient Information” section, enter email address “alice.m.austin@usace.army.mil” and click “Add”
4) In the “Email Setting” section, select:
“FOUO”,
“Encrypt email message when possible”
“Notify me when files are downloaded”
“Require CAC for Pick-up”
5) In the “File Submission” section, click on “Upload”
Contractors are responsible for ensuring the Contracting Office receives their proposal by the due date/time.
Part III. EVALUATION OF PROPOSALS
1. GENERAL ELIGIBILITY FOR TASK ORDER AWARD: In accordance with the FAR, no task order shall be entered into unless the contracting officer ensures that all requirements of law, executive orders, regulations, and all other applicable procedures, including clearances and approvals, have been met.
2. BASIS OF AWARD: Selection for award will be determined using the Low-Priced, Technically Acceptable Process in accordance with FAR 15.101-2(b)(3). An evaluation for technical acceptability will be performed on each proposal. The technically acceptable proposal that provides the lowest price will be selected for award. To be considered technically acceptable, the technical factors in the proposal must NOT be determined to be unacceptable.
The failure of a proposal to meet any of the acceptability standards for non-cost factors will result in a technically unacceptable rating and preclude award. Tradeoffs are not permitted.
Proposals are not ranked using the non-price factor.
3. EVALUATION OF THE PRICE PROPOSALS
a. Price will be evaluated and considered but will not be scored or combined with other aspects of the proposal evaluation. The proposed prices will be analyzed for reasonableness.
They may also be analyzed to determine whether they are realistic for the work to be performed, reflect a clear understanding of the requirements, and are consistent with the information provided by the Offeror. Additionally, all offers will be analyzed for unbalanced pricing.
b. An offeror may be required to confirm its price on either a CLIN, element, or total price basis, and/or provide additional information in support of their price prior to task order award at the Government’s request and discretion.
4. GENERAL TECHNICAL CRITERIA
a. Failure to include all required information may cause the proposal to be considered non-responsive and not considered further for award.
b. Proposals which are generic, vague, or lacking in detail may be considered unacceptable.
5. EVALUATION OF THE TECHNICAL PROPOSAL:
FACTOR 1, EXPERIENCE:
One of the Following Ratings will be Assigned:
Rating Description
Acceptable Proposal meets the requirements of the solicitation.
Unacceptable Proposal does not meet the requirements of the solicitation.
The Government will review the project experience submitted up to the limits specified.
Offerors must meet all of the PROPOSAL SUBMISSION REQUIREMENTS for Factor 1, Experience to receive a “ACCEPTABLE” rating:
Failure to demonstrate the minimally acceptability standards under this factor will result in an “UNACCEPTABLE” rating and possible elimination from further consideration for award.
FACTOR 2, TECHNICAL APPROACH
One of the Following Ratings will be Assigned:
Rating Description
Acceptable Proposal meets the requirements of the solicitation.
Unacceptable Proposal does not meet the requirements of the solicitation.
The Government will review the project experience submitted up to the limits specified.
Offerors must meet all of the PROPOSAL SUBMISSION REQUIREMENTS for Factor 2, Technical Approach to receive a “ACCEPTABLE” rating:
Failure to demonstrate the minimally acceptability standards under this factor will result in an “UNACCEPTABLE” rating and possible elimination from further consideration for award.
FACTOR 3, PAST PERFORMANCE:
One of the Following Ratings will be Assigned:
Rating Description Acceptable Based on the offeror’s performance record, the Government has a reasonable expectation that the offeror will successfully perform the required effort, or the offeror’s performance record is unknown. (See note below.)
Unacceptable Based on the offeror’s performance record, the Government has no reasonable expectation that the offeror will be able to successfully perform the required effort.
Note: In the case of an offeror without a record of relevant past performance or for whom information on past performance is not available or so sparse that no meaningful past performance rating can be reasonably assigned, the offeror shall be determined to have unknown past performance and shall be rated “acceptable.”
The Government will review the past performance information for the projects submitted for Factor 1, Experience and assign a rating of Acceptable or Unacceptable, as defined above.
The Government will also review recent and relevant evaluations in the PPIRS as well as any other source deemed appropriate by the Government.
Recent: All projects submitted must have been completed within the last 5 years with the Offeror being the the prime contractor.
Relevant: All projects submitted must be similar in size, scope, and complexity to that described in the solicitation.
If any negative past performance information is received to which the Offeror has not previously had an opportunity to respond, the Offeror will be given an opportunity to provide rebuttal.
END OF SECTION
SECTION 002211 ATTACHMENT 1
ACKNOWLEDGEMENT SHEET
Complete the following information and submit it with your offer:
1. Name and Address of Offeror:
2. DUNS, CAGE, and Tax Identification numbers:
3. Telephone Number:
4. Request for Proposal (RFP) Number:
5. Title of Project:
6. Names, titles, email addresses and telephone numbers of persons authorized to negotiate on the Offeror’s behalf:
7. Name and Title of Person Authorized to sign offer:
Signature:
Note: Proposals signed by an agent shall be accompanied by evidence of that agent’s authority, unless that evidence has been previously furnished to the issuing office.
8. Offer Date:
9. Amendments (Number and Date of Acknowledgement):
Number: Date: Number: Date:
10. The Offeror hereby agrees to perform the work at the prices specified in strict accordance with the terms and conditions of the RFP and any resulting award, if the offer is accepted in writing within ______ calendar days after the offers are due (Insert any number equal to or greater than the minimum requirement). Failure to insert any number means the Offeror accepts the minimum period stated. Offers providing less than the minimum requirement for Government acceptance after the date offers are due may be rejected..
SECTION 002211 ATTACHMENT 1
EXPERIENCE INFORMATION
(To be completed by Contractor)
1. Contractor:
Name:
Address:
2. Contract /Task Order(TO) /Purchase Order (PO) Number:
3. Contract/TO/PO Dollar Value:
4. Contract/TO /PO Status: Active Complete
Completion Date (w/ extensions):
5. Project Title:
Location:
6. Project Description-- to include the role of the contractor on the project and specific responsibilities of the contractor in performance of the effort:
7. Project Owner or Project Manager for the Client:
Name:
Address:
Telephone Number and E-mail:
2. ATTACHMENT TO SECTION 08 71 00 - DOOR HARDWARE - An attachment to Section 08 71 00 is provided with this amendment. See the attached bearing the notation "W9126G-16-R-0081, Amendment No. 0002".
3. ATTACHMENT TO SECTION 12 50 00 - FURNITURE SYSTEMS - The attachment to Section 12 50 00 is revised and replaced. See the attached bearing the notation "W9126G-16-R-0081, Amendment No. 0002".
(End of Summary of Changes)
3.6 HARDWARE SETS
Hardware Abbreviations and Manufacturers Scheduled
1. MK - McKinney
2. PE - Pemko
3. RO - Rockwood
4. SU - Securitron
5. SA - Sargent
6. MC - Medeco
7. RF - Rixson
8. NO - Norton
9. OT - By Others
10. 00 - Other
11. MS - Kaba Mas (Mas-Hamilton)
Hardware Schedule
Set: 1.0
Doors: 100A
Description: EXTERIOR, LEO, BMS: CVR (EO DT X NL, CYL DOG) X PULLS
2 Continuous Hinge (al/gl dr) DFM83SLF-HD1 PE 087100
1 Exit Device (cvr, cyl dogging) 16 MD8610 862 US10B SA 087100
Exit Device (cvr, nl control, cyl dogging)
16 MD8610 106 x 862 US10B SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US10B MC
1 Door Closer w/ Stop 351 CPS EB SA 087100
1 Low Energy Door Operator 6060 D 600 x 690 NO 087100
2 Sidewalk Stop 471 EXP US10B RO 087100
1 Saddle Threshold 171D MSES25 x OW PE 087100
1 Rain Drip Guard 346D x FW PE 087100
1 Perimeter Gaskets (al/gl dr) By Frame & Door Manufacturer
2 Door Sweep (al/gl dr) 315DN TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor
1 Low Energy Operator Switch Post 500 NO 087100
1 Door Actuator 505 NO 087100
1 Mullion Mount Door Actuator 503 NO 087100
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 12
W9126G-16-R-0081, Amendment No. 0002
SECTION 08 71 00 DOOR HARDWARE ATTACHMENT
Set: 1.1
Doors: 100B
Description: BRL3, DUAL READER, BMS: CVR (EO DT X STOREROOM, CYL DOG) X
ELECTRIC STRIKE
6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Exit Device (cvr, dummy lever, cyl dogging)
16 MD8610 ETJ US32D SA 087100
Exit Device (cyl, classroom lever, cyl dogging)
16 MD8613 ETJ US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
Double Door Electric Strike (exit device)
310 Series to suit application 627 FO 087100
2 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Sidewalk Stop 471 EXP US10B RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Set: 2.0
Doors: 102
Description: EXTERIOR, DUAL READER, BMS: RIM (NL, CYL DOG) X ELECTRIC STRIKE
1 Continuous Hinge (al/gl dr) DFM83SLF-HD1 PE 087100
Exit Device (rim, nl pull, cyl dogging)
16 8804 862 US10B SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US10B MC
1 Electric Strike (rim exit) 9400-LBSM 613 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer w/ Stop 351 CPS EB SA 087100
1 Saddle Threshold 171D MSES25 x OW PE 087100
1 Rain Drip Guard 346D x FW PE 087100
1 Perimeter Gaskets (al/gl dr) By Frame & Door Manufacturer
1 Door Sweep (al/gl dr) 315DN TKSP8 PE 087100
1 Door Position Switch (BMS) By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 13
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Set: 3.0
Doors: 105A, 127A, 129A
Description: EXTERIOR, DUAL READER, BMS: CVR (EO DT X NL, CYL DOG) X ELECTRIC
STRIKE
6 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
1 Exit Device (cvr, cyl dogging) 16 MD8610 862 US32D SA 087100
Exit Device (cvr, nl control, cyl dogging)
16 MD8610 106 x 862 US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
Double Door Electric Strike (exit device)
310 Series to suit application 627 FO 087100
2 Door Closer w/ Stop 351 CPS EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
2 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Set: 3.1
Doors: 130B, 133A
Description: EXTERIOR, DUAL READER, BMS: KEYED SFB X MORTISE EXIT (NL, CYL DOG)
X MAG LOCK
6 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
2 Keyed Surface Bolt 582-12 w/ padlock bracket US32D RO 087100
1 Dust Proof Strike 570 US26D RO 087100
1 Magnetic Lock (bond sensor) M62B SU 087100
Fire Exit Device (mortise, classroom lever)
12 8913 ETJ US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 14
1 Surface Overhead Stop 9-X36 652 RF 087100
1 Door Closer w/ Stop 351 CPS EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
2 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
1 Flat Bar Astragal By Door Manufacturer 00
2 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Padlock, Permanent Core, Clevis & Chain
Match Facility Standard US4 MC
Set: 3.2
Doors: 111A, 123A
Description: EXTERIOR, BMS: CVR (EO, DELAYED EGRESS)
6 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
Fire Exit Device (cvr, exit only, delayed egress)
12 59 MD8610 US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
2 Door Closer w/ Stop 351 CPS EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
2 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor
2 Electric Power Transfer EL-CEPT SU 087100
1 Power Supply By Security Contractor
Set: 3.3
Doors: 137A, 137B, 139B
Description: DUAL READER, DCS, SUPRESSION SEAL: KEYED SFB X CLASSROOM X MAG
LOCK
6 Hinge TA2714 4-1/2" x 4-1/2" (NRP) US26D MK 087100
2 Keyed Surface Bolt 582-12 w/ padlock bracket US32D RO 087100
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 15
1 Dust Proof Strike 570 US26D RO 087100
1 Magnetic Lock (bond sensor) M62B SU 087100
Mortise Lock - Classroom (ANSI F05)
8237 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Air Infiltration Gasketing 379CPK TKSP8 x H&J PE 087100
2 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
2 Door Sweep 307APK TKSP8 x DW PE 087100
1 Flat Bar Astragal By Door Manufacturer 00
1 Smoke Astragal S771C PE 087100
2 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Padlock, Permanent Core, Clevis & Chain
Match Facility Standard US4 MC
Set: 3.4
Doors: 111C
Description: DCS: CVR (CLASSROOM, LBR) X CLOSER
6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Fire Exit Device (cvr, lbr, classroom lever)
12 NB MD8613 ETJ US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
2 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor 281300
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 16
Set: 3.5
Doors: 134C
Description: ARMOR PLATE: SVR (2 CLASSROOM, LBR) X HO CLOSER X PROTECTION
6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Fire Exit Device (svr, lbr, classroom lever)
12 NB8713 ETJ US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
2 Door Closer w/ Friction Hold 351 H/ PH10 to suit application EN SA 087100
2 Armor Plate K1050 34" x DW-2" 4BE CSK US32D RO
2 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
2 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
4 Edge Guard w/ Returns 306 42" (non-mortise, cut out for hardware items)
US32D RO 087100
Set: 3.6
Doors: 110, 123B
Description: DUAL CARD READER, DCS: CVR (EO DT X STOREROOM, CYL DOG) X ELECTRIC
STRIKE
6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Exit Device (cvr, dummy lever, cyl dogging)
16 MD8610 ETJ US32D SA 087100
Exit Device (cyl, classroom lever, cyl dogging)
16 MD8613 ETJ US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
Double Door Electric Strike (exit device)
310 Series to suit application 627 FO 087100
2 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
2 Split Astragal 29324CNB TKSP8 PE 087100
2 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 17
Set: 3.7
Doors: 105B, 127B, 129B
Description: DUMMY EXIT X PULLS
6 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
2 Dummy Exit Device 8893 (fixed bar) US32D SA 087100
2 Exit Device Offset Pull Trim 862 US32D SA 087100
2 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Silencer - Metal Frame 608 RO 087100
Set: 3.8
Doors: 114
Description: MFB X STOREROOM X HO CLOSER
6 Hinge TA2714 4-1/2" x 4-1/2" (NRP) US26D MK 087100
1 Dust Proof Strike 570 US26D RO 087100
1 Manual Flush Bolt 555 x length to suit application US26D RO 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
Door Closer w/ Stop & Friction Hold
351 CPSH EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Flat Bar Astragal By Door Manufacturer 00
2 Silencer - Metal Frame 608 RO 087100
Set: 3.9
Doors: 137C, 139C
Description: RATED: STOREROOM
3 Hinge TA2714 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer w/ Stop 351 CPS EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 18
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
Set: 4.0
Doors: 111B
Description: EXTERIOR, BMS: RIM (EO, DELAYED EGRESS)
3 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
Fire Exit Device (night latch, delayed egress)
12 59 8804 862 US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer w/ Stop 351 CPS EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
1 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor
1 Electric Power Transfer EL-CEPT SU 087100
1 Power Supply By Security Contractor
Set: 4.1
Doors: 134B
Description: EXTERIOR, DUAL READER, BMS: STOREROOM X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer w/ Stop 351 CPS EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
1 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 19
Set: 4.2
Doors: 139A
Description: EXTERIOR, BMS, SUPRESSION SYSTEM: EXIT ONLY
3 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
1 Fire Exit Device (exit only) 12 8810 US32D SA 087100
1 Door Closer w/ Stop 351 CPS EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Rain Drip Guard 346C x FW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Perimeter Air Infiltration Gasketing 379CPK TKSP8 x H&J PE 087100
1 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
1 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
Set: 4.3
Doors: 132
Description: EXTERIOR, DUAL READER, BMS: STOREROOM X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3386 4-1/2" x 4-1/2" (NRP) US32D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer w/ Stop 351 CPS EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Perimeter Gasketing (hm dr) 332CS TKSP8 x H&J PE 087100
1 Rain Drip Guard 346C x FW PE 087100
1 Door Sweep w/ Drip 345APK TKSP8 x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 20
Set: 4.4
Doors: 112, 116, 138A
Description: DUAL READER, BMS: STOREROOM X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Set: 4.5
Doors: 130A, 123C
Description: DUAL READER, DCS: RIM (STOREROOM) X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Fire Exit Device (rim, storeroom lever)
12 8804 ETJ LC US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (rim exit) 9400-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 21
Set: 4.6
Doors: 136B, 138B
Description: DUAL CARD READER, DCS, SUPRESSION SEAL: STOREROOM X ELECTRIC
STRIKE
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Perimeter Air Infiltration Gasketing 379CPK TKSP8 x H&J PE 087100
1 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
1 Door Sweep 307APK TKSP8 x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
Set: 4.7
Doors: 131
Description: DCS: STOREROOM X HO CLOSER
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer w/ Friction Hold 351 H/ PH10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 22
Set: 4.8
Doors: 124, 125, 126
Description: DCS: STOREROOM X HO CLOSER X SOUND GASKETS
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer w/ Friction Hold 351 H/ PH10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold (smooth) 154A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
Set: 4.9
Doors: 107, 108, 140
Description: PASSAGE X HO CLOSER
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise :Latch - Passage (ANSI F01)
8215 LNJ US26D SA 087100
1 Door Closer w/ Friction Hold 351 H/ PH10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
3 Silencer - Metal Frame 608 RO 087100
Set: 5.0
Doors: 134A
Description: EXTERIOR, DUAL CARD READER, BMS: OH DOOR
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Overhead Coiling Door All hardware by door manufacturer (non-keyed locking system)
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 23
Set: 5.1
Doors: GATE (MAN DOOR)
Description: GATE, DUAL CARD READER, BMS: SINGLE
1 Fire Exit Device (exit only) 12 8810 US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (rim exit) 9400 LBSM 630 HS
1 SMART Pac Bridge Rectifier 2005M3 HS
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
1 Gate Assembly By Assembly Manufacturer (locking system accepts cylinder)
Set: 5.2
Doors: GATE (RECEIVING YARD)
Description: GATE, DUAL CARD READER, BMS, REMOTE RELEASE: SINGLE
1 Fire Exit Device (exit only) 12 8810 US32D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (rim exit) 9400 LBSM 630 HS
1 SMART Pac Bridge Rectifier 2005M3 HS
1 Door Position Switch (BMS) By Security Contractor
2 Credential Reader By Security Contractor
2 Power Supply By Security Contractor
1 Gate Assembly By Assembly Manufacturer (locking system accepts cylinder)
1 Remote Door Release System By Security Contractor
Set: 5.3
Doors: GATE (TURN STILE)
Description: TURNSTILE, DUAL CARD READER, BMS:
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Position Switch (BMS) By Security Contractor
1 Gate Assembly By Assembly Manufacturer (locking system accepts cylinder)
2 Credential Reader By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 24
Set: 5.4
Doors: 141
Description: DCS, 2 CR, CDX, SUPRESSION SEAL: STOREROOM X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold (smooth) 154A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Perimeter Air Infiltration Gasketing 379CPK TKSP8 x H&J PE 087100
1 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
1 Door Sweep 307APK TKSP8 x DW PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
1 Electronic Combination Lock CDX-10 GRAY MS
1 Power Supply By Security Contractor
Set: 5.5
Doors: 101
Description: BRL3, DUAL READER, BMS: STOREROOM X ELECTRIC STRIKE
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Door Position Switch (BMS) By Security Contractor
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 25
1 Credential Reader By Security Contractor
Set: 5.6
Description: GATE, BMS, REMOTE RELEASE: PAIR X EXIT DEVICE
2 Fire Exit Device (svr, nb, eo) 12 NB8710 US32D SA 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
Double Door Electric Strike (exit device)
310 Series to suit application 627 FO 087100
2 Door Position Switch (BMS) By Security Contractor
1 Power Supply By Security Contractor
2 Gate Assembly By Assembly Manufacturer (locking system accepts cylinder)
1 Remote Door Release System By Security Contractor
1 Credential Reader (egress only) By Security Contractor
Set: 3.10
Doors: 133B
Description: SUPRESSION SEAL: MFB X STOREROOM
6 Hinge TA2714 4-1/2" x 4-1/2" (NRP) US26D MK 087100
1 Dust Proof Strike 570 US26D RO 087100
2 Manual Flush Bolt 555 x length to suit application US26D RO 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer 351 O/P10 to suit application EN SA 087100
2 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
2 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold (smooth) 154A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Perimeter Air Infiltration Gasketing 379CPK TKSP8 x H&J PE 087100
2 Automatic Door Bottom (concealed) 434ARL x DW PE 087100
2 Door Sweep 307APK TKSP8 x DW PE 087100
1 Flat Bar Astragal By Door Manufacturer 00
2 Smoke Astragal S771C PE 087100
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 26
Set: 4.10
Doors: 115, 119
Description: STOREROOM X CLOSER
3 Hinge TA2714 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer w/ Friction Hold 351 H/ PH10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
Set: 4.11
Doors: 117, 118, 120, 121
Description: PUSH/PULLS
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
1 Pull Plate - 4" x 16" 107x70C US32D RO 087100
1 Push Plate - 4" x 16" 70C US32D RO 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Mop Plate K1050 5" x DW-1" 4BE CSK US32D RO
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
3 Silencer - Metal Frame 608 RO 087100
Set: 4.12
Doors: 135
Description: CLASSROOM X CLOSER
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Classroom (ANSI F05)
8237 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 27
Set: 4.13
Doors: 136A
Description: DUAL READER, DCS: STOREROOM X ELECTRIC STRIKE X THRESHOLD
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" (NRP) US26D MK 087100
Mortise Lock - Storeroom (ANSI F07)
8204 LNJ LC US26D SA 087100
Rim/Mortise Cylinder & Permanent Core
Match Facility Standard US26D MC
1 Electric Strike (lockset) 1006-LBSM 630 HS 087100
1 SMART Pac Bridge Rectifier 2005M3 HS 087100
1 Door Closer 351 O/P10 to suit application EN SA 087100
1 Kick Plate K1050 10" x DW-2" BE CSK US32D RO 087100
1 Wall Stop 406 (convex) US32D RO 087100
1 Saddle Threshold 171A MSES25 x OW PE 087100
1 Gasketing (smoke/odor/light/sound) S88BL x H&J PE 087100
1 Door Position Switch (BMS) By Security Contractor 281300
2 Credential Reader By Security Contractor
1 Power Supply By Security Contractor
END OF SECTION 08 71 00
MARCH ARB
AIR AND MARINE OPERATIONS CENTER (AMOC)
******SAFETY PAYS****** W9126G-16-R-0081
SECTION 08 71 00 - Page 28
FORT WORTH DISTRICT
ITEM CODE: B-1
EXTERIOR BENCH
QTY: 2
FINISH
MANUFACTURER: Forms & Surfaces http://www.forms-surfaces.com
MODEL NUMBER: SBKNI-072N
MODEL NAME: Knight Bench
WIDTH: 19.8"
LENGTH: 72"
HEIGHT: 18"
FINISH: Legs: Polished Aluminum Slats: Ipe
GSA
Contract Number:
Expiration Date:
LOCATION OF ITEM
Room Level Quantity Exterior Lobby Area B 2
AIR AND MARINE OPERATIONS CENTER - AMOC
MARCH AIR RESERVE BASE, CALIFORNIA
FURNITURE ILLUSTRATION | ORDER DATA SHEET
FEDERAL SUPPLY
CATEGORY:
IMAGE
DESCRIPTION:
Backless bench of solid aluminum frame with polished legs and wood slats. The wood slats are FSC 100% Ipe.
The bench is anchored to the finished floor. Maintenance of the wood slats shall be done every 6 months to preserve the natural color.
FURNITURE, FIXTURES EQUIPMENT PACKAGE
DESIGN SUBMITTAL July 8, 2016
W9126G-16-R-0081, W9126-16-R-0081, Amendment No. 0002
SECTION 12 50 00 FURNITURE SYSTEMS ATTACHMENT
http://www.forms-surfaces.com/
FURNITURE, FIXTURES EQUIPMENT PACKAGE
DESIGN SUBMITTAL July 8, 2016
FORT WORTH DISTRICT
ITEM CODE: C-1
QTY: 78
FINISH
MANUFACTURER: Herman Miller web:http://www.hermanmiller.com
MODEL NUMBER: AE113AWBPJG1BBBK3D01
MODEL NAME: Aeron Work Chair B
OVERALL WIDTH: 27"
HEIGHT: 42" Max.
SEAT HEIGHT: 15-20 7/8"
WEIGHT CAPACITY: 300 lbs.
COM/COL: Pellicle Classic Carbon 01 FINISH: Base/Frame is G1 Graphite
GSA- Herman Miller Contract Number: GS-03F-036DA Expiration Date: 12/20/2020
LOCATION OF ITEM
Room Level Quantity Security 101 Area B 3 Sys. Work Area 123 Area A 36 Info. Sys. Dir. Off. 124 Area A 1 Contract. Site Sup. 125 Area A 1 Dir. Of Info. Area A 1 Training Bull Pen 131 Area B 3 Training Room 135 Area B 13 STB 138 Area A 8 Sys. Mgmt. Conf. Area A 12
TASK CHAIR
PHOTO
DESCRIPTION:
The chair's back support offers the PostureFit support with adjustable lumbar support. The seat and back is upholstered in a Pellicle material (70% elastomeric, 30% polyester), lightweight and breathable. It features a standard pneumatic height adjustment and Kinemat tilt. The tilt limiter mechanism allows for a 5 degree forward seat angle. The chair shall have fully adjustable arms with non upholstered pads. The base is a 5 star base with 2-1/2" hard black casters. The chair is constructed of 53% recycled content. 12 year warranty, 3 shift.
FEDERAL SUPPLY
CATEGORY:
IMAGE
AIR AND MARINE OPERATIONS CENTER - AMOC
MARCH AIR RESERVE BASE, CALIFORNIA
FURNITURE ILLUSTRATION | ORDER DATA SHEET
FORT WORTH DISTRICT
ITEM CODE: C-2
QTY: 124
FINISH
MANUFACTURER: Herman Miller web: http://www.hermanmiller.com
MODEL NUMBER: AE500P-AJ-G1-SB
MODEL NAME: Aeron Side Chair B
OVERALL WIDTH: 20"
HEIGHT: 36 3/8"
SEAT HEIGHT: 17 5/8"
WEIGHT CAPACITY: 300 lbs.
COM/COL: Pellicle Classic Carbon 01 FINISH: Base/Frame is G1 Graphite
GSA- Herman Miller Contract Number: GS-03F-036DA Expiration Date: 12/20/2020
LOCATION OF ITEM
Room Level Quantity System Management Conference Room 140
Area A 6
Dir. Of Info.