Technical_Exhibit_1_Bid_Schedule_W911SG19B0001_2-26-2019.xls

XLS spreadsheet 175 KB Posted

Attached to
Fort Bliss Paving
Solicitation number
W911SG-19-B-0001
Issued by

About this file

Technical Exhibit 1 Bid Schedule W911SG19B0001 2-26-2019

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Texas -Base Year

IDIQ Paving Contract || Fort Bliss, Texas
Base Year Option - Texas AreaKeyU/I
GENERAL CONDITIONSQTYEstimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateCYCubic Yard
CLINDescriptionACRAcre
0001AAHaul and dispose of debris11815CY$ - 0CYCubic Yard
0002ABClear and Grubbing115ACR$ - 0SYSquare Yard
EARTHWORK1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateSFSquare Foot
CLINDescription1LBPound
0003ACExcavation13789CY$ - 0LFLinear Foot
0004ADFill Material (Borrow Pit)12322CY$ - 0EAEach
0005AEPrepare and Roll Sub-base, up to 8" depth172513SY$ - 0CLFCurrent Limiting Fuse
0006AFBase Course Material - Crushed 3/4" stn base, compacted, 4" depth14125SY$ - 0
0007AGBase Course Material - Crushed 3/4" stn base, compacted, 6" depth111411SY$ - 0
0008AHRe-compact exist. Base (6" depth)1823SF$ - 0
0009AIFinish Grading - it will be used after cutting or filling earth112618SY$ - 0
CONCRETE1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0010AJDemo-Reinf concrete pavement1149CY$ - 0
0011AKSawcut reinforced. concrete slab up to 4" depth1149LF$ - 0
0012AL4" Conc. slab/reinf w/ 6X6-W1.4XW1.4, broomed finish, no base115642SF$ - 0
0013AMPortland Cement Concrete Pavement -8" thick (f'c=4,000 psi)14254SY$ - 0
0014ANReinforcing steel #3 to #6 bars185061LB$ - 0
0015AONew Curb & Gutter (24"X6")1994LF$ - 0
PAVING ASPHALT1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0016APDemo- Bituminous asphalt pavement < = 3" thick1223SY$ - 0
0017AQSawcut Asphalt up to 3" depth1313LF$ - 0
0018ARPrime or Tack Coat11133SY$ - 0
0019ASInstall 2" deep HMAC, Type "B", "C", or "D"123505SY$ - 0
0020ATOverlay HMAC 1" to 2" Type "B", "C", or "D"11815SY$ - 0
0021AUCOLD MILLING 1" to 1-1/2" deep Asphaltic Pavement1364SY$ - 0
0022AVHeater Scarifying of Bituminous (1-1/2" depth)1907SY$ - 0
0023AW3" Asphalt Patching (Sawcut, Base prep, and Prime)1605SY$ - 0
0024AXPavement Slurry Sealer-(one coat)12672SY$ - 0
0025AYSealcoating, 2 coat coal tar pitch emulsion11283SY$ - 0
0026AZSealant for Cracked Asphalt - 1" wide x 2" deep1886LF$ - 0
STORM DRAIN SYSTEMS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0027BA18” Corrugated Metal Pipe, Galvanized, (16 ga)1121LF$ - 0
0028BB18" RCP Pipe (Class III)1242LF$ - 0
0029BC24" RCP Pipe (Class III)1205LF$ - 0
0030BD36" RCP Pipe (Class III)1169LF$ - 0
0031BEClass C Concrete Collar118EA$ - 0
0032BFConcrete Box Culvert (5ft x 3ft)116LF$ - 0
0033BGInlet Complete Special (Type I, II, & III)16EA$ - 0
0034BHConcrete Flume (Class B)127CY$ - 0
0035BIRip-Rap 6" thickness, not grouted125SY$ - 0
0036BJRip-Rap (Concrete Class B) (4" to 6")118CY$ - 0
0037BKRemove Storm Drain Pipe (Up to 36" Diameter)1221LF$ - 0
0038BLGabion Box Systems, 12" deep145SY$ - 0
0039BMCement Stabilized Backfill1151CY$ - 0
MISCELLANEOUS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0040BNTopographic Survey, conventional14ACR$ - 0
0041BODensity Test by Nuclear Method (Sub-Grade & Base)110EA$ - 0
0042BPMoisture/Density Relationship Proctor ASTM D1557, D698 (Sub-Grade & Base)110EA$ - 0
0043BQCompressive Strength of Cylinders & Concrete Cores (ASTM C39)110EA$ - 0
0044BRSlump Test110EA$ - 0
0045BSDensity Test by Nuclear Method ASTM D6939 (Asphalt)110EA$ - 0
0046BTQuantitative Extraction / Sieve Analysis Gradation ASTM D2172110EA$ - 0
0047BUMarshall Density, Stability & Flow ASTM 2726, D6926, & D6927110EA$ - 0
0048BVTheoretical Maximum Specific Gravity & Density ASTM D2041110EA$ - 0
0049BWBulk Specific Gravity and Density of Asphalt Pavent Cores (ASTM D2726)110EA$ - 0
0050BXAsphalt Core Measurement ASTM D3549110EA$ - 0
0051BYMoisture & density test by nuclear method1205EA$ - 0
0052BZADA Ramp w/truncated dome mat19EA$ - 0
0053CA24” x 24” Traffic Reflectorized Sign w/post and break away - installed123EA$ - 0
0054CBSolar Powered Pedestrian Sign13EA$ - 0
0055CCReflectorized Thermoplastic Single Solid Traffic Striping (4" Wide)129267LF$ - 0
0056CDReflectorized Thermoplastic Symbol: Arrow11360SF$ - 0
0057CEConcrete Wheel Stops130EA$ - 0
0058CFRemove Chain Link Fence17264LF$ - 0
0059CGChain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel,14137LF$ - 0
0060CHPrivacy slats, vertical, vinyl11034SF$ - 0
0061CIPrivacy slats, diagonal, aluminum11034SF$ - 0
0062CJRockwall 1ft width1302SF$ - 0
0063CKVehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C.166LF$ - 0
0064CLVehicle Guide Rails, End Sections, galvanized, flared139EA$ - 0
0065CMVehicle Guide Rails, Wrap around end142EA$ - 0
0066CN1-1/4" Pea Gravel1289CY$ - 0
0067CO1 ¼" Franklin Red Rock w/6 mil plastic - 2" deep11210SF$ - 0
0068CP3/4" Desert Tan Rock w/6 mil plastic - 2" deep11210SF$ - 0
0069CQTraffic Control Plan Design15EA$ - 0
0070CR28" Min Tubular With Two Retroflective Bands150EA$ - 0
0071CSTemporary Striping1500LF$ - 0
0072CTTemporary Barrels150EA$ - 0
0073CUTemporary signs 36"x36"122EA$ - 0
0074CVTemporary Jersey Barriers150EA$ - 0
0075CWTemporary Type 3 Barricades110EA$ - 0
0076CXHay Bales125EA$ - 0
0077CYSilt Fencing11499LF$ - 0
0078CZRemove Pavement Markings (Grinding)11000SF$ - 0
0079DARemove Traffic Sign, Post, and Foundation1100EA$ - 0
0080DBRemove Guardrail1200LF$ - 0
0081DCUtility Trench 12"wide x 24" deep12269LF$ - 0
ELETRICAL1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0082DDRelocate Light Pole and Assembly (Including Concrete Base)19EA$ - 0
0083DERemove Light Pole and Assembly (Including Concrete Base)112EA$ - 0
0084DFSolar Roadway Light, 300W LED121EA$ - 0
0085DGEMT 1/2" to 1"1307LF$ - 0
0086DHSafety Switch 60A, 240V Fusible16EA$ - 0
0087DISafety Switch 100A, 240V Fusible16EA$ - 0
0088DJCircuitbreaker Panelboard 200A13EA$ - 0
0089DK#12-#2 THHN Cu.131CLF$ - 0
0090DL#1/0-#4/0 THHN Cu.112CLF$ - 0
0091DMMetal Light Pole, excl concrete base, 40 ft112EA$ - 0
0092DNWood Light Pole, 20 ft112EA$ - 0
0093DOLED equivalent (in lumens) to 400W Metal Halid Fixture115EA$ - 0
0094DPCrimp 2 way connectors #6-#2161EA$ - 0
0095DQCrimp 2 way connectors #1/0-#4/0146EA$ - 0
0096DR#12-#10 THWN-THHN111CLF$ - 0
0097DS#8-#2 THHN-THWN19CLF$ - 0
0098DT#1/0-#4/0 THWN-THHN131CLF$ - 0
0099DU3/4" Cu. Clad 10 ft. ground rod131EA$ - 0
0100DVGrnd Rod Clamp 3/4"118EA$ - 0
0101DWBare Cu. #6115CLF$ - 0
0102DXExothermic Weld (Cadweld)112EA$ - 0
0103DY1/2"-3/4" RGS1614LF$ - 0
0104DZ1"-2" RGS1461LF$ - 0
0105EA1/2"-3/4" RGS elbow143EA$ - 0
0106EB1"-2" RGS elbow131EA$ - 0
0107EC1/2"-3/4" Sch 40 PVC1154LF$ - 0
0108ED1"-2" Sch 40 PVC1871LF$ - 0
0109EE1/2"-3/4" Sch 40 PVC adapters131EA$ - 0
0110EF1"-2" Sch 40 PVC adapters161EA$ - 0
0111EG1/2"-3/4" Grounding Bushing131EA$ - 0
0112EH1"-2" Grounding Bushing125EA$ - 0
0113EI12"x12"x6" NEMA 113EA$ - 0
0114EJ12"x12"x6" NEMA 3R13EA$ - 0
0115EKHole drilling, 8-12" thick concrete wall, 1" pipe112EA$ - 0
0116ELHole drilling, 8-12" thick concrete wall, 2" pipe112EA$ - 0
0117EM480VX120/208 3 ph 30KVA13EA$ - 0
0118EN120V 1 pole bolt on to 50A112EA$ - 0
0119EO240V 2 pole bolt on to 50A112EA$ - 0
0120EP240V 3 pole bolt on to 100A16EA$ - 0
0121EQ277V 1 pole bolt 30A16EA$ - 0
0122ER480V 2 pole bolt on 60A16EA$ - 0
0123ES480V 3 pole bolt on to 100A16EA$ - 0
0124ET3 ph 4 w 120/208V 100A 24 ckt w/breakers MCB13EA$ - 0
0125EU3 ph 4 w 277/480V 100A 20 ckt w/breakers MCB13EA$ - 0
0126EV3 ph Fused Disconnect HD 240V 30A Nema 3R15EA$ - 0
0127EW3 ph Fused Disconnect HD 240V 60A Nema 3R15EA$ - 0
0128EX3 ph Fused Disconnect HD 600V 30A Nema 3R14EA$ - 0
0129EY3 ph Fused Disconnect HD 600V 60A Nema 3R14EA$ - 0
0130EZSingle pole, dial17EA$ - 0
0131FAPhotocell 2000W116EA$ - 0
0132FBEnclosed AC contactor, 600V, electrically held, 60A16EA$ - 0
0133FCEnclosed AC contactor, 600V, electrically held, 100A14EA$ - 0
0134FDHD Start/Stop111EA$ - 0
0135FELight Poles, Aluminum, not incl concrete base 20 ft113EA$ - 0
0136FFLight Poles, Aluminum, not incl concrete base 30 ft15EA$ - 0
0137FGLight Poles, Aluminum, not incl concrete base 40 ft14EA$ - 0
0138FHArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide15EA$ - 0
0139FIArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS19EA$ - 0
0140FJFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 175W Metal Halide15EA$ - 0
0141FKFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide15EA$ - 0
0142FLFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 100W HPS15EA$ - 0
0143FMFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 150W HPS16EA$ - 0
0144FNFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS16EA$ - 0
0145FO20 ft. Wood Pole Class 319EA$ - 0
0146FP30 ft. Wood Pole Class 319EA$ - 0
0147FQ40 ft. Wood Pole Class 319EA$ - 0
TOTAL$ - 0

NM -Base Year

IDIQ Paving Contract || Fort Bliss, Texas
Base Year Option - New Mexico AreaKeyU/I
GENERAL CONDITIONSQTYEstimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateCYCubic Yard
CLINDescriptionACRAcre
0001AAHaul and dispose of debris1450CY$ - 0CYCubic Yard
0002ABClear and Grubbing14ACR$ - 0SYSquare Yard
EARTHWORK1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateSFSquare Foot
CLINDescription1LBPound
0003ACExcavation11197CY$ - 0LFLinear Foot
0004ADFill Material (Borrow Pit)1576CY$ - 0EAEach
0005AEPrepare and Roll Sub-base, up to 8" depth117851SY$ - 0CLFCurrent Limiting Fuse
0006AFBase Course Material - Crushed 3/4" stn base, compacted, 4" depth11023SY$ - 0
0007AGBase Course Material - Crushed 3/4" stn base, compacted, 6" depth13198SY$ - 0
0008AHRe-compact exist. Base (6" depth)1204SF$ - 0
0009AIFinish Grading - it will be used after cutting or filling earth13129SY$ - 0
CONCRETE1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0010AJDemo-Reinf concrete pavement137CY$ - 0
0011AKSawcut reinforced. concrete slab up to 4" depth137LF$ - 0
0012AL4" Conc. slab/reinf w/ 6X6-W1.4XW1.4, broomed finish, no base13878SF$ - 0
0013AMPortland Cement Concrete Pavement -8" thick (f'c=4,000 psi)1812SY$ - 0
0014ANReinforcing steel #3 to #6 bars118495LB$ - 0
0015AONew Curb & Gutter (24"X6")1246LF$ - 0
PAVING ASPHALT1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0016APDemo- Bituminous asphalt pavement < = 3" thick155SY$ - 0
0017AQSawcut Asphalt up to 3" depth178LF$ - 0
0018ARPrime or Tack Coat1281SY$ - 0
0019ASInstall 2" deep HMAC, Type "B", "C", or "D"15579SY$ - 0
0020ATOverlay HMAC 1" to 2" Type "B", "C", or "D"1450SY$ - 0
0021AUCOLD MILLING 1" to 1-1/2" deep Asphaltic Pavement190SY$ - 0
0022AVHeater Scarifying of Bituminous (1-1/2" depth)1225SY$ - 0
0023AW3" Asphalt Patching (Sawcut, Base prep, and Prime)1150SY$ - 0
0024AXPavement Slurry Sealer-(one coat)1663SY$ - 0
0025AYSealcoating, 2 coat coal tar pitch emulsion1318SY$ - 0
0026AZSealant for Cracked Asphalt - 1" wide x 2" deep1220LF$ - 0
STORM DRAIN SYSTEMS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0027BA18” Corrugated Metal Pipe, Galvanized, (16 ga)130LF$ - 0
0028BB18" RCP Pipe (Class III)160LF$ - 0
0029BC24" RCP Pipe (Class III)151LF$ - 0
0030BD36" RCP Pipe (Class III)42LF$ - 0
0031BEClass C Concrete Collar14EA$ - 0
0032BFConcrete Box Culvert (5ft x 3ft)14LF$ - 0
0033BGInlet Complete Special (Type I, II, & III)11EA$ - 0
0034BHConcrete Flume (Class B)17CY$ - 0
0035BIRip-Rap 6" thickness, not grouted16SY$ - 0
0036BJRip-Rap (Concrete Class B) (4" to 6")14CY$ - 0
0037BKRemove Storm Drain Pipe (Up to 36" Diameter)1101LF$ - 0
0038BLGabion Box Systems, 12" deep111SY$ - 0
0039BMCement Stabilized Backfill137CY$ - 0
MISCELLANEOUS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0040BNTopographic Survey, conventional11ACR$ - 0
0041BODensity Test by Nuclear Method (Sub-Grade & Base)16EA$ - 0
0042BPMoisture/Density Relationship Proctor ASTM D1557, D698 (Sub-Grade & Base)16EA$ - 0
0043BQCompressive Strength of Cylinders & Concrete Cores (ASTM C39)16EA$ - 0
0044BRSlump Test16EA$ - 0
0045BSDensity Test by Nuclear Method ASTM D6939 (Asphalt)16EA$ - 0
0046BTQuantitative Extraction / Sieve Analysis Gradation ASTM D217216EA$ - 0
0047BUMarshall Density, Stability & Flow ASTM 2726, D6926, & D692716EA$ - 0
0048BVTheoretical Maximum Specific Gravity & Density ASTM D204116EA$ - 0
0049BWBulk Specific Gravity and Density of Asphalt Pavent Cores (ASTM D2726)16EA$ - 0
0050BXAsphalt Core Measurement ASTM D354916EA$ - 0
0051BYMoisture & density test by nuclear method151EA$ - 0
0052BZADA Ramp w/truncated dome mat12EA$ - 0
0053CA24” x 24” Traffic Reflectorized Sign w/post and break away - installed16EA$ - 0
0054CBSolar Powered Pedestrian Sign11EA$ - 0
0055CCReflectorized Thermoplastic Single Solid Traffic Striping (4" Wide)15124LF$ - 0
0056CDReflectorized Thermoplastic Symbol: Arrow1277SF$ - 0
0057CEConcrete Wheel Stops18EA$ - 0
0058CFRemove Chain Link Fence11801LF$ - 0
0059CGChain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel,1859LF$ - 0
0060CHPrivacy slats, vertical, vinyl1256SF$ - 0
0061CIPrivacy slats, diagonal, aluminum1256SF$ - 0
0062CJRockwall 1ft width175SF$ - 0
0063CKVehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C.116LF$ - 0
0064CLVehicle Guide Rails, End Sections, galvanized, flared110EA$ - 0
0065CMVehicle Guide Rails, Wrap around end110EA$ - 0
0066CN1-1/4" Pea Gravel172CY$ - 0
0067CO1 ¼" Franklin Red Rock w/6 mil plastic - 2" deep1300SF$ - 0
0068CP3/4" Desert Tan Rock w/6 mil plastic - 2" deep1300SF$ - 0
0069CQTraffic Control Plan Design15EA$ - 0
0070CR28" Min Tubular With Two Retroflective Bands133EA$ - 0
0071CSTemporary Striping1175LF$ - 0
0072CTTemporary Barrels122EA$ - 0
0073CUTemporary signs 36"x36"117EA$ - 0
0074CVTemporary Jersey Barriers132EA$ - 0
0075CWTemporary Type 3 Barricades15EA$ - 0
0076CXHay Bales110EA$ - 0
0077CYSilt Fencing1769LF$ - 0
0078CZRemove Pavement Markings (Grinding)1778SF$ - 0
0079DARemove Traffic Sign, Post, and Foundation160EA$ - 0
0080DBRemove Guardrail1120LF$ - 0
0081DCUtility Trench 12"wide x 24" deep1562LF$ - 0
ELETRICAL1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0082DDRelocate Light Pole and Assembly (Including Concrete Base)12EA$ - 0
0083DERemove Light Pole and Assembly (Including Concrete Base)13EA$ - 0
0084DFSolar Roadway Light, 300W LED15EA$ - 0
0085DGEMT 1/2" to 1"176LF$ - 0
0086DHSafety Switch 60A, 240V Fusible12EA$ - 0
0087DISafety Switch 100A, 240V Fusible12EA$ - 0
0088DJCircuitbreaker Panelboard 200A11EA$ - 0
0089DK#12-#2 THHN Cu.18CLF$ - 0
0090DL#1/0-#4/0 THHN Cu.13CLF$ - 0
0091DMMetal Light Pole, excl concrete base, 40 ft13EA$ - 0
0092DNWood Light Pole, 20 ft13EA$ - 0
0093DOLED equivalent (in lumens) to 400W Metal Halid Fixture14EA$ - 0
0094DPCrimp 2 way connectors #6-#2115EA$ - 0
0095DQCrimp 2 way connectors #1/0-#4/0111EA$ - 0
0096DR#12-#10 THWN-THHN13CLF$ - 0
0097DS#8-#2 THHN-THWN12CLF$ - 0
0098DT#1/0-#4/0 THWN-THHN18CLF$ - 0
0099DU3/4" Cu. Clad 10 ft. ground rod18EA$ - 0
0100DVGrnd Rod Clamp 3/4"15EA$ - 0
0101DWBare Cu. #614CLF$ - 0
0102DXExothermic Weld (Cadweld)13EA$ - 0
0103DY1/2"-3/4" RGS1152LF$ - 0
0104DZ1"-2" RGS1114LF$ - 0
0105EA1/2"-3/4" RGS elbow111EA$ - 0
0106EB1"-2" RGS elbow18EA$ - 0
0107EC1/2"-3/4" Sch 40 PVC138LF$ - 0
0108ED1"-2" Sch 40 PVC1216LF$ - 0
0109EE1/2"-3/4" Sch 40 PVC adapters18EA$ - 0
0110EF1"-2" Sch 40 PVC adapters115EA$ - 0
0111EG1/2"-3/4" Grounding Bushing18EA$ - 0
0112EH1"-2" Grounding Bushing16EA$ - 0
0113EI12"x12"x6" NEMA 111EA$ - 0
0114EJ12"x12"x6" NEMA 3R11EA$ - 0
0115EKHole drilling, 8-12" thick concrete wall, 1" pipe13EA$ - 0
0116ELHole drilling, 8-12" thick concrete wall, 2" pipe13EA$ - 0
0117EM480VX120/208 3 ph 30KVA11EA$ - 0
0118EN120V 1 pole bolt on to 50A13EA$ - 0
0119EO240V 2 pole bolt on to 50A13EA$ - 0
0120EP240V 3 pole bolt on to 100A12EA$ - 0
0121EQ277V 1 pole bolt 30A12EA$ - 0
0122ER480V 2 pole bolt on 60A12EA$ - 0
0123ES480V 3 pole bolt on to 100A12EA$ - 0
0124ET3 ph 4 w 120/208V 100A 24 ckt w/breakers MCB11EA$ - 0
0125EU3 ph 4 w 277/480V 100A 20 ckt w/breakers MCB11EA$ - 0
0126EV3 ph Fused Disconnect HD 240V 30A Nema 3R11EA$ - 0
0127EW3 ph Fused Disconnect HD 240V 60A Nema 3R11EA$ - 0
0128EX3 ph Fused Disconnect HD 600V 30A Nema 3R11EA$ - 0
0129EY3 ph Fused Disconnect HD 600V 60A Nema 3R11EA$ - 0
0130EZSingle pole, dial12EA$ - 0
0131FAPhotocell 2000W14EA$ - 0
0132FBEnclosed AC contactor, 600V, electrically held, 60A12EA$ - 0
0133FCEnclosed AC contactor, 600V, electrically held, 100A11EA$ - 0
0134FDHD Start/Stop13EA$ - 0
0135FELight Poles, Aluminum, not incl concrete base 20 ft13EA$ - 0
0136FFLight Poles, Aluminum, not incl concrete base 30 ft11EA$ - 0
0137FGLight Poles, Aluminum, not incl concrete base 40 ft11EA$ - 0
0138FHArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide11EA$ - 0
0139FIArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS12EA$ - 0
0140FJFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 175W Metal Halide11EA$ - 0
0141FKFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide11EA$ - 0
0142FLFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 100W HPS11EA$ - 0
0143FMFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 150W HPS12EA$ - 0
0144FNFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS12EA$ - 0
0145FO20 ft. Wood Pole Class 312EA$ - 0
0146FP30 ft. Wood Pole Class 312EA$ - 0
0147FQ40 ft. Wood Pole Class 312EA$ - 0
TOTAL$ - 0

Texas - Year Option 1

IDIQ Paving Contract || Fort Bliss, Texas
Year Option 1 - Texas AreaKeyU/I
GENERAL CONDITIONSQTYEstimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateCYCubic Yard
CLINDescriptionACRAcre
1001AAHaul and dispose of debris11762CY$ - 0CYCubic Yard
1002ABClear and Grubbing115ACR$ - 0SYSquare Yard
EARTHWORK1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateSFSquare Foot
CLINDescription1LBPound
1003ACExcavation14687CY$ - 0LFLinear Foot
1004ADFill Material (Borrow Pit)12254CY$ - 0EAEach
1005AEPrepare and Roll Sub-base, up to 8" depth176221SY$ - 0CLFCurrent Limiting Fuse
1006AFBase Course Material - Crushed 3/4" stn base, compacted, 4" depth14004SY$ - 0
1007AGBase Course Material - Crushed 3/4" stn base, compacted, 6" depth110591SY$ - 0
1008AHRe-compact exist. Base (6" depth)1799SF$ - 0
1009AIFinish Grading - it will be used after cutting or filling earth112251SY$ - 0
CONCRETE1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1010AJDemo-Reinf concrete pavement1145CY$ - 0
1011AKSawcut reinforced. concrete slab up to 4" depth1145LF$ - 0
1012AL4" Conc. slab/reinf w/ 6X6-W1.4XW1.4, broomed finish, no base115187SF$ - 0
1013AMPortland Cement Concrete Pavement -8" thick (f'c=4,000 psi)14130SY$ - 0
1014ANReinforcing steel #3 to #6 bars182584LB$ - 0
1015AONew Curb & Gutter (24"X6")1965LF$ - 0
PAVING ASPHALT1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1016APDemo- Bituminous asphalt pavement < = 3" thick1217SY$ - 0
1017AQSawcut Asphalt up to 3" depth1304LF$ - 0
1018ARPrime or Tack Coat11100SY$ - 0
1019ASInstall 2" deep HMAC, Type "B", "C", or "D"122984SY$ - 0
1020ATOverlay HMAC 1" to 2" Type "B", "C", or "D"11762SY$ - 0
1021AUCOLD MILLING 1" to 1-1/2" deep Asphaltic Pavement1353SY$ - 0
1022AVHeater Scarifying of Bituminous (1-1/2" depth)1881SY$ - 0
1023AW3" Asphalt Patching (Sawcut, Base prep, and Prime)1587SY$ - 0
1024AXPavement Slurry Sealer-(one coat)12594SY$ - 0
1025AYSealcoating, 2 coat coal tar pitch emulsion11246SY$ - 0
1026AZSealant for Cracked Asphalt - 1" wide x 2" deep1860LF$ - 0
STORM DRAIN SYSTEMS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1027BA18” Corrugated Metal Pipe, Galvanized, (16 ga)1117LF$ - 0
1028BB18" RCP Pipe (Class III)1205LF$ - 0
1029BC24" RCP Pipe (Class III)1174LF$ - 0
1030BD36" RCP Pipe (Class III)143LF$ - 0
1031BEClass C Concrete Collar118EA$ - 0
1032BFConcrete Box Culvert (5ft x 3ft)115LF$ - 0
1033BGInlet Complete Special (Type I, II, & III) Install Additional 1' Depth to Inlet16EA$ - 0
1034BHConcrete Flume (Class B)126CY$ - 0
1035BIRip-Rap 6" thickness, not grouted124SY$ - 0
1036BJRip-Rap (Concrete Class B) (4" to 6")118CY$ - 0
1037BKRemove Storm Drain Pipe (Up to 36" Diameter)1221LF$ - 0
1038BLGabion Box Systems, 12" deep144SY$ - 0
1039BMCement Stabilized Backfill1147CY$ - 0
MISCELLANEOUS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1040BNTopographic Survey, conventional14ACR$ - 0
1041BODensity Test by Nuclear Method (Sub-Grade & Base)110EA$ - 0
1042BPMoisture/Density Relationship Proctor ASTM D1557, D698 (Sub-Grade & Base)110EA$ - 0
1043BQCompressive Strength of Cylinders & Concrete Cores (ASTM C39)110EA$ - 0
1044BRSlump Test110EA$ - 0
1045BSDensity Test by Nuclear Method ASTM D6939 (Asphalt)110EA$ - 0
1046BTQuantitative Extraction / Sieve Analysis Gradation ASTM D2172110EA$ - 0
1047BUMarshall Density, Stability & Flow ASTM 2726, D6926, & D6927110EA$ - 0
1048BVTheoretical Maximum Specific Gravity & Density ASTM D2041110EA$ - 0
1049BWBulk Specific Gravity and Density of Asphalt Pavent Cores (ASTM D2726)110EA$ - 0
1050BXAsphalt Core Measurement ASTM D3549110EA$ - 0
1051BYMoisture & density test by nuclear method1199EA$ - 0
1052BZADA Ramp w/truncated dome mat18EA$ - 0
1053CA24” x 24” Traffic Reflectorized Sign w/post and break away - installed122EA$ - 0
1054CBSolar Powered Pedestrian Sign13EA$ - 0
1055CCReflectorized Thermoplastic Single Solid Traffic Striping (4" Wide)122359LF$ - 0
1056CDReflectorized Thermoplastic Symbol: Arrow11320SF$ - 0
1057CEConcrete Wheel Stops129EA$ - 0
1058CFRemove Chain Link Fence16500LF$ - 0
1059CGChain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel,13520LF$ - 0
1060CHPrivacy slats, vertical, vinyl11004SF$ - 0
1061CIPrivacy slats, diagonal, aluminum11004SF$ - 0
1062CJRockwall 1ft width1294SF$ - 0
1063CKVehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C.164LF$ - 0
1064CLVehicle Guide Rails, End Sections, galvanized, flared137EA$ - 0
1065CMVehicle Guide Rails, Wrap around end141EA$ - 0
1066CN1-1/4" Pea Gravel1281CY$ - 0
1067CO1 ¼" Franklin Red Rock w/6 mil plastic - 2" deep11175SF$ - 0
1068CP3/4" Desert Tan Rock w/6 mil plastic - 2" deep11175SF$ - 0
1069CQTraffic Control Plan Design15EA$ - 0
1070CR28" Min Tubular With Two Retroflective Bands150EA$ - 0
1071CSTemporary Striping1500LF$ - 0
1072CTTemporary Barrels150EA$ - 0
1073CUTemporary signs 36"x36"122EA$ - 0
1074CVTemporary Jersey Barriers150EA$ - 0
1075CWTemporary Type 3 Barricades110EA$ - 0
1076CXHay Bales125EA$ - 0
1077CYSilt Fencing11499LF$ - 0
1078CZRemove Pavement Markings (Grinding)11000SF$ - 0
1079DARemove Traffic Sign, Post, and Foundation1100EA$ - 0
1080DBRemove Guardrail1200LF$ - 0
1081DCUtility Trench 12"wide x 24" deep12203LF$ - 0
ELETRICAL1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1082DDRelocate Light Pole and Assembly (Including Concrete Base)19EA$ - 0
1083DERemove Light Pole and Assembly (Including Concrete Base)112EA$ - 0
1084DFSolar Roadway Light, 300W LED121EA$ - 0
1085DGEMT 1/2" to 1"1298LF$ - 0
1086DHSafety Switch 60A, 240V Fusible16EA$ - 0
1087DISafety Switch 100A, 240V Fusible16EA$ - 0
1088DJCircuitbreaker Panelboard 200A13EA$ - 0
1089DK#12-#2 THHN Cu.130CLF$ - 0
1090DL#1/0-#4/0 THHN Cu.112CLF$ - 0
1091DMMetal Light Pole, excl concrete base, 40 ft112EA$ - 0
1092DNWood Light Pole, 20 ft112EA$ - 0
1093DOLED equivalent (in lumens) to 400W Metal Halid Fixture115EA$ - 0
1094DPCrimp 2 way connectors #6-#2160EA$ - 0
1095DQCrimp 2 way connectors #1/0-#4/0145EA$ - 0
1096DR#12-#10 THWN-THHN111CLF$ - 0
1097DS#8-#2 THHN-THWN19CLF$ - 0
1098DT#1/0-#4/0 THWN-THHN130CLF$ - 0
1099DU3/4" Cu. Clad 10 ft. ground rod130EA$ - 0
1100DVGrnd Rod Clamp 3/4"118EA$ - 0
1101DWBare Cu. #6115CLF$ - 0
1102DXExothermic Weld (Cadweld)112EA$ - 0
1103DY1/2"-3/4" RGS1596LF$ - 0
1104DZ1"-2" RGS1447LF$ - 0
1105EA1/2"-3/4" RGS elbow142EA$ - 0
1106EB1"-2" RGS elbow130EA$ - 0
1107EC1/2"-3/4" Sch 40 PVC1149LF$ - 0
1108ED1"-2" Sch 40 PVC1846LF$ - 0
1109EE1/2"-3/4" Sch 40 PVC adapters130EA$ - 0
1110EF1"-2" Sch 40 PVC adapters160EA$ - 0
1111EG1/2"-3/4" Grounding Bushing130EA$ - 0
1112EH1"-2" Grounding Bushing124EA$ - 0
1113EI12"x12"x6" NEMA 113EA$ - 0
1114EJ12"x12"x6" NEMA 3R13EA$ - 0
1115EKHole drilling, 8-12" thick concrete wall, 1" pipe112EA$ - 0
1116ELHole drilling, 8-12" thick concrete wall, 2" pipe112EA$ - 0
1117EM480VX120/208 3 ph 30KVA13EA$ - 0
1118EN120V 1 pole bolt on to 50A112EA$ - 0
1119EO240V 2 pole bolt on to 50A112EA$ - 0
1120EP240V 3 pole bolt on to 100A16EA$ - 0
1121EQ277V 1 pole bolt 30A16EA$ - 0
1122ER480V 2 pole bolt on 60A16EA$ - 0
1123ES480V 3 pole bolt on to 100A16EA$ - 0
1124ET3 ph 4 w 120/208V 100A 24 ckt w/breakers MCB13EA$ - 0
1125EU3 ph 4 w 277/480V 100A 20 ckt w/breakers MCB13EA$ - 0
1126EV3 ph Fused Disconnect HD 240V 30A Nema 3R15EA$ - 0
1127EW3 ph Fused Disconnect HD 240V 60A Nema 3R15EA$ - 0
1128EX3 ph Fused Disconnect HD 600V 30A Nema 3R14EA$ - 0
1129EY3 ph Fused Disconnect HD 600V 60A Nema 3R14EA$ - 0
1130EZSingle pole, dial17EA$ - 0
1131FAPhotocell 2000W116EA$ - 0
1132FBEnclosed AC contactor, 600V, electrically held, 60A16EA$ - 0
1133FCEnclosed AC contactor, 600V, electrically held, 100A14EA$ - 0
1134FDHD Start/Stop111EA$ - 0
1135FELight Poles, Aluminum, not incl concrete base 20 ft112EA$ - 0
1136FFLight Poles, Aluminum, not incl concrete base 30 ft15EA$ - 0
1137FGLight Poles, Aluminum, not incl concrete base 40 ft14EA$ - 0
1138FHArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide15EA$ - 0
1139FIArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS19EA$ - 0
1140FJFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 175W Metal Halide15EA$ - 0
1141FKFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide15EA$ - 0
1142FLFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 100W HPS15EA$ - 0
1143FMFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 150W HPS16EA$ - 0
1144FNFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS16EA$ - 0
1145FO20 ft. Wood Pole Class 319EA$ - 0
1146FP30 ft. Wood Pole Class 319EA$ - 0
1147FQ40 ft. Wood Pole Class 319EA$ - 0
TOTAL$ - 0

NM -Year Option 1

IDIQ Paving Contract || Fort Bliss, Texas
Year Option 1 - New Mexico AreaKeyU/I
GENERAL CONDITIONSQTYEstimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateCYCubic Yard
CLINDescriptionACRAcre
1001AAHaul and dispose of debris1437CY$ - 0CYCubic Yard
1002ABClear and Grubbing14ACR$ - 0SYSquare Yard
EARTHWORK1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price EstimateSFSquare Foot
CLINDescription1LBPound
1003ACExcavation11162CY$ - 0LFLinear Foot
1004ADFill Material (Borrow Pit)1559CY$ - 0EAEach
1005AEPrepare and Roll Sub-base, up to 8" depth117331SY$ - 0CLFCurrent Limiting Fuse
1006AFBase Course Material - Crushed 3/4" stn base, compacted, 4" depth1993SY$ - 0
1007AGBase Course Material - Crushed 3/4" stn base, compacted, 6" depth13105SY$ - 0
1008AHRe-compact exist. Base (6" depth)1198SF$ - 0
1009AIFinish Grading - it will be used after cutting or filling earth13037SY$ - 0
CONCRETE1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1010AJDemo-Reinf concrete pavement136CY$ - 0
1011AKSawcut reinforced. concrete slab up to 4" depth136LF$ - 0
1012AL4" Conc. slab/reinf w/ 6X6-W1.4XW1.4, broomed finish, no base13765SF$ - 0
1013AMPortland Cement Concrete Pavement -8" thick (f'c=4,000 psi)1788SY$ - 0
1014ANReinforcing steel #3 to #6 bars117956LB$ - 0
1015AONew Curb & Gutter (24"X6")1239LF$ - 0
PAVING ASPHALT1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1016APDemo- Bituminous asphalt pavement < = 3" thick154SY$ - 0
1017AQSawcut Asphalt up to 3" depth175LF$ - 0
1018ARPrime or Tack Coat1273SY$ - 0
1019ASInstall 2" deep HMAC, Type "B", "C", or "D"15417SY$ - 0
1020ATOverlay HMAC 1" to 2" Type "B", "C", or "D"1437SY$ - 0
1021AUCOLD MILLING 1" to 1-1/2" deep Asphaltic Pavement188SY$ - 0
1022AVHeater Scarifying of Bituminous (1-1/2" depth)1218SY$ - 0
1023AW3" Asphalt Patching (Sawcut, Base prep, and Prime)1146SY$ - 0
1024AXPavement Slurry Sealer-(one coat)1643SY$ - 0
1025AYSealcoating, 2 coat coal tar pitch emulsion1309SY$ - 0
1026AZSealant for Cracked Asphalt - 1" wide x 2" deep1213LF$ - 0
STORM DRAIN SYSTEMS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1027BA18” Corrugated Metal Pipe, Galvanized, (16 ga)129LF$ - 0
1028BB18" RCP Pipe (Class III)158LF$ - 0
1029BC24" RCP Pipe (Class III)149LF$ - 0
1030BD36" RCP Pipe (Class III)41LF$ - 0
1031BEClass C Concrete Collar14EA$ - 0
1032BFConcrete Box Culvert (5ft x 3ft)14LF$ - 0
1033BGInlet Complete Special (Type I, II, & III)11EA$ - 0
1034BHConcrete Flume (Class B)16CY$ - 0
1035BIRip-Rap 6" thickness, not grouted16SY$ - 0
1036BJRip-Rap (Concrete Class B) (4" to 6")14CY$ - 0
1037BKRemove Storm Drain Pipe (Up to 36" Diameter)1101LF$ - 0
1038BLGabion Box Systems, 12" deep111SY$ - 0
1039BMCement Stabilized Backfill136CY$ - 0
MISCELLANEOUS1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1040BNTopographic Survey, conventional11ACR$ - 0
1041BODensity Test by Nuclear Method (Sub-Grade & Base)16EA$ - 0
1042BPMoisture/Density Relationship Proctor ASTM D1557, D698 (Sub-Grade & Base)16EA$ - 0
1043BQCompressive Strength of Cylinders & Concrete Cores (ASTM C39)16EA$ - 0
1044BRSlump Test16EA$ - 0
1045BSDensity Test by Nuclear Method ASTM D6939 (Asphalt)16EA$ - 0
1046BTQuantitative Extraction / Sieve Analysis Gradation ASTM D217216EA$ - 0
1047BUMarshall Density, Stability & Flow ASTM 2726, D6926, & D692716EA$ - 0
1048BVTheoretical Maximum Specific Gravity & Density ASTM D204116EA$ - 0
1049BWBulk Specific Gravity and Density of Asphalt Pavent Cores (ASTM D2726)16EA$ - 0
1050BXAsphalt Core Measurement ASTM D354916EA$ - 0
1051BYMoisture & density test by nuclear method149EA$ - 0
1052BZADA Ramp w/truncated dome mat12EA$ - 0
1053CA24” x 24” Traffic Reflectorized Sign w/post and break away - installed15EA$ - 0
1054CBSolar Powered Pedestrian Sign11EA$ - 0
1055CCReflectorized Thermoplastic Single Solid Traffic Striping (4" Wide)17045LF$ - 0
1056CDReflectorized Thermoplastic Symbol: Arrow1327SF$ - 0
1057CEConcrete Wheel Stops17EA$ - 0
1058CFRemove Chain Link Fence11448LF$ - 0
1059CGChain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel,1834LF$ - 0
1060CHPrivacy slats, vertical, vinyl1249SF$ - 0
1061CIPrivacy slats, diagonal, aluminum1249SF$ - 0
1062CJRockwall 1ft width173SF$ - 0
1063CKVehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C.116LF$ - 0
1064CLVehicle Guide Rails, End Sections, galvanized, flared19EA$ - 0
1065CMVehicle Guide Rails, Wrap around end110EA$ - 0
1066CN1-1/4" Pea Gravel170CY$ - 0
1067CO1 ¼" Franklin Red Rock w/6 mil plastic - 2" deep1291SF$ - 0
1068CP3/4" Desert Tan Rock w/6 mil plastic - 2" deep1291SF$ - 0
1069CQTraffic Control Plan Design15EA$ - 0
1070CR28" Min Tubular With Two Retroflective Bands133EA$ - 0
1071CSTemporary Striping1175LF$ - 0
1072CTTemporary Barrels122EA$ - 0
1073CUTemporary signs 36"x36"117EA$ - 0
1074CVTemporary Jersey Barriers132EA$ - 0
1075CWTemporary Type 3 Barricades15EA$ - 0
1076CXHay Bales110EA$ - 0
1077CYSilt Fencing1769LF$ - 0
1078CZRemove Pavement Markings (Grinding)1778SF$ - 0
1079DARemove Traffic Sign, Post, and Foundation160EA$ - 0
1080DBRemove Guardrail1120LF$ - 0
1081DCUtility Trench 12"wide x 24" deep1546LF$ - 0
ELETRICAL1Estimated QtyU/IUnit Price ( Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
1082DDRelocate Light Pole and Assembly (Including Concrete Base)12EA$ - 0
1083DERemove Light Pole and Assembly (Including Concrete Base)13EA$ - 0
1084DFSolar Roadway Light, 300W LED14EA$ - 0
1085DGEMT 1/2" to 1"174LF$ - 0
1086DHSafety Switch 60A, 240V Fusible11EA$ - 0
1087DISafety Switch 100A, 240V Fusible11EA$ - 0
1088DJCircuitbreaker Panelboard 200A11EA$ - 0
1089DK#12-#2 THHN Cu.17CLF$ - 0
1090DL#1/0-#4/0 THHN Cu.13CLF$ - 0
1091DMMetal Light Pole, excl concrete base, 40 ft13EA$ - 0
1092DNWood Light Pole, 20 ft13EA$ - 0
1093DOLED equivalent (in lumens) to 400W Metal Halid Fixture14EA$ - 0
1094DPCrimp 2 way connectors #6-#2115EA$ - 0
1095DQCrimp 2 way connectors #1/0-#4/0111EA$ - 0
1096DR#12-#10 THWN-THHN13CLF$ - 0
1097DS#8-#2 THHN-THWN12CLF$ - 0
1098DT#1/0-#4/0 THWN-THHN17CLF$ - 0
1099DU3/4" Cu. Clad 10 ft. ground rod17EA$ - 0
1100DVGrnd Rod Clamp 3/4"14EA$ - 0
1101DWBare Cu. #614CLF$ - 0
1102DXExothermic Weld (Cadweld)13EA$ - 0
1103DY1/2"-3/4" RGS1148LF$ - 0
1104DZ1"-2" RGS1111LF$ - 0
1105EA1/2"-3/4" RGS elbow110EA$ - 0
1106EB1"-2" RGS elbow17EA$ - 0
1107EC1/2"-3/4" Sch 40 PVC137LF$ - 0
1108ED1"-2" Sch 40 PVC1210LF$ - 0
1109EE1/2"-3/4" Sch 40 PVC adapters17EA$ - 0
1110EF1"-2" Sch 40 PVC adapters115EA$ - 0
1111EG1/2"-3/4" Grounding Bushing17EA$ - 0
1112EH1"-2" Grounding Bushing16EA$ - 0
1113EI12"x12"x6" NEMA 111EA$ - 0
1114EJ12"x12"x6" NEMA 3R11EA$ - 0
1115EKHole drilling, 8-12" thick concrete wall, 1" pipe13EA$ - 0
1116ELHole drilling, 8-12" thick concrete wall, 2" pipe13EA$ - 0
1117EM480VX120/208 3 ph 30KVA11EA$ - 0
1118EN120V 1 pole bolt on to 50A13EA$ - 0
1119EO240V 2 pole bolt on to 50A13EA$ - 0
1120EP240V 3 pole bolt on to 100A11EA$ - 0
1121EQ277V 1 pole bolt 30A11EA$ - 0
1122ER480V 2 pole bolt on 60A11EA$ - 0
1123ES480V 3 pole bolt on to 100A11EA$ - 0
1124ET3 ph 4 w 120/208V 100A 24 ckt w/breakers MCB11EA$ - 0
1125EU3 ph 4 w 277/480V 100A 20 ckt w/breakers MCB11EA$ - 0
1126EV3 ph Fused Disconnect HD 240V 30A Nema 3R11EA$ - 0
1127EW3 ph Fused Disconnect HD 240V 60A Nema 3R11EA$ - 0
1128EX3 ph Fused Disconnect HD 600V 30A Nema 3R11EA$ - 0
1129EY3 ph Fused Disconnect HD 600V 60A Nema 3R11EA$ - 0
1130EZSingle pole, dial12EA$ - 0
1131FAPhotocell 2000W14EA$ - 0
1132FBEnclosed AC contactor, 600V, electrically held, 60A12EA$ - 0
1133FCEnclosed AC contactor, 600V, electrically held, 100A11EA$ - 0
1134FDHD Start/Stop13EA$ - 0
1135FELight Poles, Aluminum, not incl concrete base 20 ft13EA$ - 0
1136FFLight Poles, Aluminum, not incl concrete base 30 ft11EA$ - 0
1137FGLight Poles, Aluminum, not incl concrete base 40 ft11EA$ - 0
1138FHArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide11EA$ - 0
1139FIArea Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS12EA$ - 0
1140FJFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 175W Metal Halide11EA$ - 0
1141FKFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W Metal Halide11EA$ - 0
1142FLFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 100W HPS11EA$ - 0
1143FMFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 150W HPS12EA$ - 0
1144FNFlood Lighting Fixture pole mtd with LED equivalent (in lumens) to 400W HPS12EA$ - 0
1145FO20 ft. Wood Pole Class 312EA$ - 0
1146FP30 ft. Wood Pole Class 312EA$ - 0
1147FQ40 ft. Wood Pole Class 312EA$ - 0
TOTAL$ - 0

File details come from the government source that posted it.