W911RQ-18-R-0268.pdf
PDF 604 KB Posted
- Attached to
- REFUSE COLLECTION & TRANSPORTATION SERVICES
- Solicitation number
- W911RQ-18-R-0268
About this file
SOLICITATION_REFUSE COLLECTION AND TRANSPORTATION
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
W911RQ-18-R-0268 09-Feb-2017
b. TELEPHONE NUMBER
(903)334-4283
8. OFFER DUE DATE/LOCAL TIME
10:00 AM 09 Mar 2018
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
W911RQ9. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
SANDRA JEAN-LOUIS
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED OR X
SMALL BUSINESSX
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
RED RIVER ARMY DEPOT
DIRECTORATE FOR CONTRACTING
100 JAMES CARLOW DRIVE BLDG 431
TEXARKANA TX 75501-5000
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE W911RQ 16. ADMINISTERED BY
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
X SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
TEL: 903-334-4220 FAX:
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
$38,500,000
NAICS:
562111
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF102
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT
41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
W911RQ-18-R-0268
Section SF 1449 - CONTINUATION SHEET
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
BASE YEAR_REFUSE COLLECTION
FFP
Contractor will furnish all equipment, tools, supplies, labor, transportation and supervision for the accomplishment of the collection and hauling of refuse from RRAD, Texarkana, TX, in strict accordance with the Performance Work Statement
(PWS).
Refuse collection will include, but not limited to a range of collection containers from 40 cubic yard (CY) roll-off boxes to compactors; Transportation of refuse to an approved disposal site will require the contractor to comply with Department of Transportation (DOT) and the State of Texas rules and regulations for transporting solid waste. The contractor shall perform to the standards in the contract as well as all Local, State, and Federal regulations
WAGE DETERMINATIONS No: 2015-5146 REVISION 3, POSTED on www.wdol.gov dated 08/03/2017 Area: Arkansas Counties of Little River, Miller Texas County of Bowie
NET AMT
0001AA 59 Each Four (4) Cubic Yard Container
FFP
Four (4) Cubic Yard Container Each Per Month
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container and equipped with dual lids and lid handles, with lid-opening assist springs or approved alternates. Interior height shall be 48 inches plus or minus 2 in.
FOB: Destination
PSC CD: S205
0001AB 45 Each Eight (8) Cubic Yard Container without S
FFP
Eight (8) Cubic Yard Container Without Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container.
0001AC 45 Each Eight (8) Cubic Yard Container With Slid
FFP
Eight (8) Cubic Yard Container With Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container. Each container shall be equipped with 28 in x 28 in or larger sliding doors (with handles) on each end and with one sliding door with an opening of 30 in x 34 in or greater on the rear lid. Alternate dimensions may be submitted for approval.
0001AD 1 Each Eight (8) Cubic Yard Container Modified
FFP
Eight (8) Cubic Yard Container Modified for Sawdust Collection Each Per Month.
This one (1) container requires a metal lid modified to accept saw dust from a collector system. This will require a minimum of six (6) inch to eight (8) inch diameter opening in the metal lid.
0001AE 5 Each Dock load compactor 40-42 CY Co
FFP
Dock Load or Thru-wall Stationary Compactor with 40-42 Cubic Yard Container Each Per Month.
Compactor system shall conform to American National Standards Institute (ANSI) specification Z245.1-84: Safety Requirements for Refuse Collection and Compaction Equipment. The contractor shall submit written certification to the KO/COR from the equipment manufacturer(s) that the compactor systems being installed for this contract comply with ANSI Z245.1-84, NEMA standards, National Electric Code, and (NFPA 70).
0001AF 7 Each End or Side Ground Load S. Compactor
FFP
End or Side Ground Load Stationary Compactor with Roll-Off Each Per Month.
The compactor chutes shall be constructed of 10 gauge or thicker steel on top and sides and 1/4 inch steel on bottom and shall be reinforced and anchored to insure structural rigidity. Chutes shall have a 30 in x 48 in or larger inspection door at the charging chamber
0001AG 5 Each Fifteen (15) Cubic Yard Open Top Roll of
FFP
Fifteen (15) Cubic Yard Open Top Roll off Container Each Per Month.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage and Collection of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
0001AH 5 Each Forty (40) Cubic Yard Open Top Roll off
FFP
Forty (40) Cubic Yard Open Top Roll off Container Each.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
0001AJ 25 Each Relocate Red River Managed Roll Off Cont
FFP
Relocate Red River Managed Roll Off Containers ON DEPOT ONLY.
Red River Army Depot maintains a roll-off truck to switch out Red River Managed roll-offs at waste collection sites on depot when they are full. There are occasions when this vehicle is inoperable and the contractor, upon the request of the KO/COR, will be asked to supply this service.
0001AK 203 Each Transportation of Full Containers to Lan
FFP
Transportation of Full Containers to Landfill.
All containers, except those for sawdust, wood and dust collectors, shall be serviced a minimum of twice each week or frequent enough to provide service before capacity loading is approached. Compactors shall be serviced at a minimum twice each month.
0001AL 1 Lot
CONTRACTOR MANPOWER SURVEY
FFP
The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor will report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The contractor is required to completely fill in all the information in the format using the following web address: https://www.ecmra.mil/
OPTION FIRST OPTION_REFUSE COLLECTION
FFP
Contractor will furnish all equipment, tools, supplies, labor, transportation and supervision for the accomplishment of the collection and hauling of refuse from RRAD, Texarkana, TX, in strict accordance with the Performance Work Statement
(PWS).
Refuse collection will include, but not limited to a range of collection containers from 40 cubic yard (CY) roll-off boxes to compactors; Transportation of refuse to an approved disposal site will require the contractor to comply with Department of Transportation (DOT) and the State of Texas rules and regulations for transporting solid waste. The contractor shall perform to the standards in the contract as well as all Local, State, and Federal regulations
WAGE DETERMINATIONS No: 2015-5146 REVISION 3, POSTED on www.wdol.gov dated 08/03/2017
1001AA 59 Each OPTION Four (4) Cubic Yard Container
FFP
Four (4) Cubic Yard Container Each Per Month
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container and equipped with dual lids and lid handles, with lid-opening assist springs or approved alternates. Interior height shall be 48 inches plus or minus 2 in.
1001AB 45 Each OPTION Eight (8) Cubic Yard Container without S
FFP
Eight (8) Cubic Yard Container Without Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container.
1001AC 45 Each OPTION Eight (8) Cubic Yard Container With Slid
FFP
Eight (8) Cubic Yard Container With Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container. Each container shall be equipped with 28 in x 28 in or larger sliding doors (with handles) on each end and with one sliding door with an opening of 30 in x 34 in or greater on the rear lid. Alternate dimensions may be submitted for approval.
1001AD 1 Each OPTION Eight (8) Cubic Yard Container Modified
FFP
Eight (8) Cubic Yard Container Modified for Sawdust Collection Each Per Month.
This one (1) container requires a metal lid modified to accept saw dust from a collector system. This will require a minimum of six (6) inch to eight (8) inch diameter opening in the metal lid.
1001AE 5 Each OPTION Dock load compactor 40-42 CY Co
FFP
Dock Load or Thru-wall Stationary Compactor with 40-42 Cubic Yard Container Each Per Month.
Compactor system shall conform to American National Standards Institute (ANSI) specification Z245.1-84: Safety Requirements for Refuse Collection and Compaction Equipment. The contractor shall submit written certification to the KO/COR from the equipment manufacturer(s) that the compactor systems being installed for this contract comply with ANSI Z245.1-84, NEMA standards, National Electric Code, and (NFPA 70).
1001AF 7 Each OPTION End or Side Ground Load S. Compactor
FFP
End or Side Ground Load Stationary Compactor with Roll-Off Each Per Month.
The compactor chutes shall be constructed of 10 gauge or thicker steel on top and sides and 1/4 inch steel on bottom and shall be reinforced and anchored to insure structural rigidity. Chutes shall have a 30 in x 48 in or larger inspection door at the charging chamber
1001AG 5 Each OPTION Fifteen (15) Cubic Yard Open Top Roll of
FFP
Fifteen (15) Cubic Yard Open Top Roll off Container Each Per Month.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage and Collection of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
1001AH 5 Each OPTION Forty (40) Cubic Yard Open Top Roll off
FFP
Forty (40) Cubic Yard Open Top Roll off Container Each.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
1001AJ 25 Each OPTION Relocate Red River Managed Roll Off Cont
FFP
Relocate Red River Managed Roll Off Containers ON DEPOT ONLY.
Red River Army Depot maintains a roll-off truck to switch out Red River Managed roll-offs at waste collection sites on depot when they are full. There are occasions when this vehicle is inoperable and the contractor, upon the request of the KO/COR, will be asked to supply this service.
1001AK 203 Each OPTION Transportation of Full Containers to Lan
FFP
Transportation of Full Containers to Landfill.
All containers, except those for sawdust, wood and dust collectors, shall be serviced a minimum of twice each week or frequent enough to provide service before capacity loading is approached. Compactors shall be serviced at a minimum twice each month.
1001AL 1 Lot
OPTION CONTRACTOR MANPOWER SURVEY
FFP
The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor will report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The contractor is required to completely fill in all the information in the format using the following web address: https://www.ecmra.mil/
OPTION SECOND OPTION_REFUSE COLLECTION
FFP
Contractor will furnish all equipment, tools, supplies, labor, transportation and supervision for the accomplishment of the collection and hauling of refuse from RRAD, Texarkana, TX, in strict accordance with the Performance Work Statement
(PWS).
Refuse collection will include, but not limited to a range of collection containers from 40 cubic yard (CY) roll-off boxes to compactors; Transportation of refuse to an approved disposal site will require the contractor to comply with Department of Transportation (DOT) and the State of Texas rules and regulations for transporting solid waste. The contractor shall perform to the standards in the contract as well as all Local, State, and Federal regulations
WAGE DETERMINATIONS No: 2015-5146 REVISION 3, POSTED on www.wdol.gov dated 08/03/2017
2001AA 59 Each OPTION Four (4) Cubic Yard Container
FFP
Four (4) Cubic Yard Container Each Per Month
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container and equipped with dual lids and lid handles, with lid-opening assist springs or approved alternates. Interior height shall be 48 inches plus or minus 2 in.
2001AB 45 Each OPTION Eight (8) Cubic Yard Container without S
FFP
Eight (8) Cubic Yard Container Without Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container.
2001AC 45 Each OPTION Eight (8) Cubic Yard Container With Slid
FFP
Eight (8) Cubic Yard Container With Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container. Each container shall be equipped with 28 in x 28 in or larger sliding doors (with handles) on each end and with one sliding door with an opening of 30 in x 34 in or greater on the rear lid. Alternate dimensions may be submitted for approval.
2001AD 1 Each OPTION Eight (8) Cubic Yard Container Modified
FFP
Eight (8) Cubic Yard Container Modified for Sawdust Collection Each Per Month.
This one (1) container requires a metal lid modified to accept saw dust from a collector system. This will require a minimum of six (6) inch to eight (8) inch diameter opening in the metal lid.
2001AE 5 Each OPTION Dock load compactor 40-42 CY Co
FFP
Dock Load or Thru-wall Stationary Compactor with 40-42 Cubic Yard Container Each Per Month.
Compactor system shall conform to American National Standards Institute (ANSI) specification Z245.1-84: Safety Requirements for Refuse Collection and Compaction Equipment. The contractor shall submit written certification to the KO/COR from the equipment manufacturer(s) that the compactor systems being installed for this contract comply with ANSI Z245.1-84, NEMA standards, National Electric Code, and (NFPA 70).
2001AF 7 Each OPTION End or Side Ground Load S. Compactor
FFP
End or Side Ground Load Stationary Compactor with Roll-Off Each Per Month.
The compactor chutes shall be constructed of 10 gauge or thicker steel on top and sides and 1/4 inch steel on bottom and shall be reinforced and anchored to insure structural rigidity. Chutes shall have a 30 in x 48 in or larger inspection door at the charging chamber
2001AG 5 Each OPTION Fifteen (15) Cubic Yard Open Top Roll of
FFP
Fifteen (15) Cubic Yard Open Top Roll off Container Each Per Month.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage and Collection of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
2001AH 5 Each OPTION Forty (40) Cubic Yard Open Top Roll off
FFP
Forty (40) Cubic Yard Open Top Roll off Container Each.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
2001AJ 25 Each OPTION Relocate Red River Managed Roll Off Cont
FFP
Relocate Red River Managed Roll Off Containers ON DEPOT ONLY.
Red River Army Depot maintains a roll-off truck to switch out Red River Managed roll-offs at waste collection sites on depot when they are full. There are occasions when this vehicle is inoperable and the contractor, upon the request of the KO/COR, will be asked to supply this service.
2001AK 203 Each OPTION Transportation of Full Containers to Lan
FFP
Transportation of Full Containers to Landfill.
All containers, except those for sawdust, wood and dust collectors, shall be serviced a minimum of twice each week or frequent enough to provide service before capacity loading is approached. Compactors shall be serviced at a minimum twice each month.
2001AL 1 Lot
OPTION CONTRACTOR MANPOWER SURVEY
FFP
The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor will report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The contractor is required to completely fill in all the information in the format using the following web address: https://www.ecmra.mil/
OPTION THIRD OPTION_REFUSE COLLECTION
FFP
Contractor will furnish all equipment, tools, supplies, labor, transportation and supervision for the accomplishment of the collection and hauling of refuse from RRAD, Texarkana, TX, in strict accordance with the Performance Work Statement
(PWS).
Refuse collection will include, but not limited to a range of collection containers from 40 cubic yard (CY) roll-off boxes to compactors; Transportation of refuse to an approved disposal site will require the contractor to comply with Department of Transportation (DOT) and the State of Texas rules and regulations for transporting solid waste. The contractor shall perform to the standards in the contract as well as all Local, State, and Federal regulations
WAGE DETERMINATIONS No: 2015-5146 REVISION 3, POSTED on www.wdol.gov dated 08/03/2017
3001AA 59 Each OPTION Four (4) Cubic Yard Container
FFP
Four (4) Cubic Yard Container Each Per Month
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container and equipped with dual lids and lid handles, with lid-opening assist springs or approved alternates. Interior height shall be 48 inches plus or minus 2 in.
3001AB 45 Each OPTION Eight (8) Cubic Yard Container without S
FFP
Eight (8) Cubic Yard Container Without Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container.
3001AC 45 Each OPTION Eight (8) Cubic Yard Container With Slid
FFP
Eight (8) Cubic Yard Container With Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container. Each container shall be equipped with 28 in x 28 in or larger sliding doors (with handles) on each end and with one sliding door with an opening of 30 in x 34 in or greater on the rear lid. Alternate dimensions may be submitted for approval.
3001AD 1 Each OPTION Eight (8) Cubic Yard Container Modified
FFP
Eight (8) Cubic Yard Container Modified for Sawdust Collection Each Per Month.
This one (1) container requires a metal lid modified to accept saw dust from a collector system. This will require a minimum of six (6) inch to eight (8) inch diameter opening in the metal lid.
3001AE 5 Each OPTION Dock load compactor 40-42 CY Co
FFP
Dock Load or Thru-wall Stationary Compactor with 40-42 Cubic Yard Container Each Per Month.
Compactor system shall conform to American National Standards Institute (ANSI) specification Z245.1-84: Safety Requirements for Refuse Collection and Compaction Equipment. The contractor shall submit written certification to the KO/COR from the equipment manufacturer(s) that the compactor systems being installed for this contract comply with ANSI Z245.1-84, NEMA standards, National Electric Code, and (NFPA 70).
3001AF 7 Each OPTION End or Side Ground Load S. Compactor
FFP
End or Side Ground Load Stationary Compactor with Roll-Off Each Per Month.
The compactor chutes shall be constructed of 10 gauge or thicker steel on top and sides and 1/4 inch steel on bottom and shall be reinforced and anchored to insure structural rigidity. Chutes shall have a 30 in x 48 in or larger inspection door at the charging chamber
3001AG 5 Each OPTION Fifteen (15) Cubic Yard Open Top Roll of
FFP
Fifteen (15) Cubic Yard Open Top Roll off Container Each Per Month.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage and Collection of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
3001AH 5 Each OPTION Forty (40) Cubic Yard Open Top Roll off
FFP
Forty (40) Cubic Yard Open Top Roll off Container Each.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
3001AJ 25 Each OPTION Relocate Red River Managed Roll Off Cont
FFP
Relocate Red River Managed Roll Off Containers ON DEPOT ONLY.
Red River Army Depot maintains a roll-off truck to switch out Red River Managed roll-offs at waste collection sites on depot when they are full. There are occasions when this vehicle is inoperable and the contractor, upon the request of the KO/COR, will be asked to supply this service.
3001AK 203 Each OPTION Transportation of Full Containers to Lan
FFP
Transportation of Full Containers to Landfill.
All containers, except those for sawdust, wood and dust collectors, shall be serviced a minimum of twice each week or frequent enough to provide service before capacity loading is approached. Compactors shall be serviced at a minimum twice each month.
3001AL 1 Lot
OPTION CONTRACTOR MANPOWER SURVEY
FFP
The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor will report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The contractor is required to completely fill in all the information in the format using the following web address: https://www.ecmra.mil/
OPTION FOURTH OPTION_REFUSE COLLECTION
FFP
Contractor will furnish all equipment, tools, supplies, labor, transportation and supervision for the accomplishment of the collection and hauling of refuse from RRAD, Texarkana, TX, in strict accordance with the Performance Work Statement
(PWS).
Refuse collection will include, but not limited to a range of collection containers from 40 cubic yard (CY) roll-off boxes to compactors; Transportation of refuse to an approved disposal site will require the contractor to comply with Department of Transportation (DOT) and the State of Texas rules and regulations for transporting solid waste. The contractor shall perform to the standards in the contract as well as all Local, State, and Federal regulations
WAGE DETERMINATIONS No: 2015-5146 REVISION 3, POSTED on www.wdol.gov dated 08/03/2017
4001AA 59 Each OPTION Four (4) Cubic Yard Container
FFP
Four (4) Cubic Yard Container Each Per Month
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container and equipped with dual lids and lid handles, with lid-opening assist springs or approved alternates. Interior height shall be 48 inches plus or minus 2 in.
4001AB 45 Each OPTION Eight (8) Cubic Yard Container without S
FFP
Eight (8) Cubic Yard Container Without Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container.
4001AC 45 Each OPTION Eight (8) Cubic Yard Container With Slid
FFP
Eight (8) Cubic Yard Container With Sliding Lids Each Per Month.
Shall be heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1.
Containers shall be equipped with a 1-1/2 inch nominal diameter threaded drain and plug on each container. Each container shall be equipped with 28 in x 28 in or larger sliding doors (with handles) on each end and with one sliding door with an opening of 30 in x 34 in or greater on the rear lid. Alternate dimensions may be submitted for approval.
4001AD 1 Each OPTION Eight (8) Cubic Yard Container Modified
FFP
Eight (8) Cubic Yard Container Modified for Sawdust Collection Each Per Month.
This one (1) container requires a metal lid modified to accept saw dust from a collector system. This will require a minimum of six (6) inch to eight (8) inch diameter opening in the metal lid.
4001AE 5 Each OPTION Dock load compactor 40-42 CY Co
FFP
Dock Load or Thru-wall Stationary Compactor with 40-42 Cubic Yard Container Each Per Month.
Compactor system shall conform to American National Standards Institute (ANSI) specification Z245.1-84: Safety Requirements for Refuse Collection and Compaction Equipment. The contractor shall submit written certification to the KO/COR from the equipment manufacturer(s) that the compactor systems being installed for this contract comply with ANSI Z245.1-84, NEMA standards, National Electric Code, and (NFPA 70).
4001AF 7 Each OPTION End or Side Ground Load S. Compactor
FFP
End or Side Ground Load Stationary Compactor with Roll-Off Each Per Month.
The compactor chutes shall be constructed of 10 gauge or thicker steel on top and sides and 1/4 inch steel on bottom and shall be reinforced and anchored to insure structural rigidity. Chutes shall have a 30 in x 48 in or larger inspection door at the charging chamber
4001AG 5 Each OPTION Fifteen (15) Cubic Yard Open Top Roll of
FFP
Fifteen (15) Cubic Yard Open Top Roll off Container Each Per Month.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage and Collection of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
4001AH 5 Each OPTION Forty (40) Cubic Yard Open Top Roll off
FFP
Forty (40) Cubic Yard Open Top Roll off Container Each.
Roll off containers shall be of heavy-duty steel construction that meets or exceeds the standards established by the American National Standards Institute (ANSI) for waste containers as follows: Waste Containers Safety Requirements, 1994, American National Standards Institute, ANSI Z245.30-1994; and Waste Containers Compatibility Dimensions, 1996, American National Standards Institute, ANSI Z245.60-1996 as referenced in 40 Code of Federal Regulations (Guidelines For The Storage And Collection Of Residential, Commercial, And Institutional Solid Waste) 243.200-1. Containers shall be equipped with a 1-1/2 in nominal diameter threaded drain and plug on each container.
4001AJ 25 Each OPTION Relocate Red River Managed Roll Off Cont
FFP
Relocate Red River Managed Roll Off Containers ON DEPOT ONLY.
Red River Army Depot maintains a roll-off truck to switch out Red River Managed roll-offs at waste collection sites on depot when they are full. There are occasions when this vehicle is inoperable and the contractor, upon the request of the KO/COR, will be asked to supply this service.
4001AK 203 Each OPTION Transportation of Full Containers to Lan
FFP
Transportation of Full Containers to Landfill.
All containers, except those for sawdust, wood and dust collectors, shall be serviced a minimum of twice each week or frequent enough to provide service before capacity loading is approached. Compactors shall be serviced at a minimum twice each month.
4001AL 1 Lot
OPTION CONTRACTOR MANPOWER SURVEY
FFP
The Office of the Assistant Secretary of the Army (Manpower & Reserve Affairs) operates and maintains a secure Army data collection site where the contractor will report ALL contractor manpower (including subcontractor manpower) required for performance of this contract. The contractor is required to completely fill in all the information in the format using the following web address: https://www.ecmra.mil/
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 N/A N/A N/A N/A 0001AA Destination Government Destination Government 0001AB Destination Government Destination Government 0001AC Destination Government Destination Government 0001AD Destination Government Destination Government 0001AE Destination Government Destination Government 0001AF Destination Government Destination Government 0001AG Destination Government Destination Government 0001AH Destination Government Destination Government 0001AJ Destination Government Destination Government 0001AK Destination Government Destination Government 0001AL Destination Government Destination Government 1001 N/A N/A N/A N/A 1001AA Destination Government Destination Government 1001AB Destination Government Destination Government 1001AC Destination Government Destination Government 1001AD Destination Government Destination Government 1001AE Destination Government Destination Government 1001AF Destination Government Destination Government 1001AG Destination Government Destination Government 1001AH Destination Government Destination Government 1001AJ Destination Government Destination Government 1001AK Destination Government Destination Government 1001AL Destination Government Destination Government 2001 N/A N/A N/A N/A 2001AA Destination Government Destination Government 2001AB Destination Government Destination Government 2001AC Destination Government Destination Government 2001AD Destination Government Destination Government 2001AE Destination Government Destination Government 2001AF Destination Government Destination Government 2001AG Destination Government Destination Government 2001AH Destination Government Destination Government 2001AJ Destination Government Destination Government 2001AK Destination Government Destination Government 2001AL Destination Government Destination Government 3001 N/A N/A N/A N/A 3001AA Destination Government Destination Government 3001AB Destination Government Destination Government 3001AC Destination Government Destination Government 3001AD Destination Government Destination Government 3001AE Destination Government Destination Government 3001AF Destination Government Destination Government 3001AG Destination Government Destination Government 3001AH Destination Government Destination Government 3001AJ Destination Government Destination Government 3001AK Destination Government Destination Government 3001AL Destination Government Destination Government 4001 N/A N/A N/A N/A 4001AA Destination Government Destination Government 4001AB Destination Government Destination Government 4001AC Destination Government Destination Government
4001AD Destination Government Destination Government 4001AE Destination Government Destination Government 4001AF Destination Government Destination Government 4001AG Destination Government Destination Government 4001AH Destination Government Destination Government 4001AJ Destination Government Destination Government 4001AK Destination Government Destination Government 4001AL Destination Government Destination Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
0001 N/A N/A N/A N/A
0001AA POP 22-AUG-2018 TO
21-AUG-2019
N/A RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
903-334-4220
W911RQ
0001AB POP 22-AUG-2018 TO
21-AUG-2019
N/A (SAME AS PREVIOUS LOCATION)
0001AC POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AD POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AE POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AF POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AG POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AH POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AJ POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AK POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
0001AL POP 22-AUG-2018 TO
N/A (SAME AS PREVIOUS LOCATION)
1001 N/A N/A N/A N/A
1001AA POP 22-AUG-2019 TO
21-AUG-2020
N/A RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
903-334-4220
1001AB POP 22-AUG-2019 TO
21-AUG-2020
N/A (SAME AS PREVIOUS LOCATION)
1001AC POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AD POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AE POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AF POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AG POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AH POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AJ POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AK POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
1001AL POP 22-AUG-2019 TO
N/A (SAME AS PREVIOUS LOCATION)
2001 N/A N/A N/A N/A
2001AA POP 22-AUG-2020 TO
21-AUG-2021
N/A RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
903-334-4220
2001AB POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AC POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AD POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AE POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AF POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AG POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AH POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AJ POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AK POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
2001AL POP 22-AUG-2020 TO
N/A (SAME AS PREVIOUS LOCATION)
3001 N/A N/A N/A N/A
3001AA POP 22-AUG-2021 TO
21-AUG-2022
N/A RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
903-334-4220
3001AB POP 22-AUG-2021 TO
21-AUG-2022
N/A (SAME AS PREVIOUS LOCATION)
3001AC POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AD POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AE POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AF POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AG POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AH POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AJ POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AK POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
3001AL POP 22-AUG-2021 TO
N/A (SAME AS PREVIOUS LOCATION)
4001 N/A N/A N/A N/A
4001AA POP 22-AUG-2022 TO
21-AUG-2023
N/A RED RIVER ARMY DEPOT
CARMEN OAKLEY
RED RIVER ARMY DEPOT
ENVIRONMENTAL DIVISION
BLDG 303B
TEXARKANA TX 75501
903-334-4220
4001AB POP 22-AUG-2022 TO
21-AUG-2023
N/A (SAME AS PREVIOUS LOCATION)
4001AC POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AD POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AE POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AF POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AG POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AH POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AJ POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AK POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
4001AL POP 22-AUG-2022 TO
N/A (SAME AS PREVIOUS LOCATION)
CLAUSES INCORPORATED BY REFERENCE
52.203-3 Gratuities APR 1984 52.203-7 Anti-Kickback Procedures MAY 2014 52.203-12 Limitation On Payments To Influence Certain Federal
Transactions
OCT 2010
52.203-19 Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements
JAN 2017
52.204-4 Printed or Copied Double-Sided on Postconsumer Fiber Content Paper
MAY 2011
52.204-9 Personal Identity Verification of Contractor Personnel JAN 2011 52.204-10 Reporting Executive Compensation and First-Tier
Subcontract Awards
OCT 2016
52.209-10 Prohibition on Contracting With Inverted Domestic Corporations
NOV 2015
52.212-4 Contract Terms and Conditions--Commercial Items JAN 2017 52.212-5 (Dev) Contract Terms and Conditions Required to Implement
Statutes or Executive Orders--Commercial Items (Deviation 2013-O0019)
NOV 2017
52.219-14…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.