Text version

MAINTENANCE ENGINEERING ORDER

(AMCOM Reg. 750-2)

MEO NO.

DATE PAGE 1 of

TITLE Tolerances Unless otherwise noted, dimensions are in inches and tolerances are:

Fractional ………………… ± 1/32 Decimal ………………... ± 0.010 Angular ………………… ± ½°

APPLICABILITY CSI Critical Characteristic Affected?

Impact Statement Attached?

REFERENCES FOR RDECOM USE ONLY

DOCUMENT(S) AFFECTED

PURPOSE OR PROBLEM

PROJECT ENGINEER ENGINEERING REVIEW ENGINEERING RELEASE

MED FORM 5-DEC-09 1401-R-E

E 2090 Apr 11, 2017 4

IUID Parts Marking Updates to WP 0009 00 Manifold, Hydraulic System Accessories, Primary and Utility P/Ns 266500-1003/-1005/-1007/-1009 266600-1003, 266600-1005/-1007/-1009

Technical

INTERIM USE OF THIS MEO IS AUTHORIZED

UNTIL AFFECTED DOCUMENT IS UPDATED.

MEO CHANGE TYPE

4) Normal - Can be implemented with normal priorityPRIORITY IMPLEMENTATION CATEGORY

AH64 DAA

TN 167826 11/3/2016

DMWR 1-4730-390 DATED 31 MAY 2016

DOCUMENT CHANGE IS REQUIRED Verification: Hands-On Table-Top None

Changes based on DMWR MEO IUID Review (TN 167439). Implement MEO's E2090, E2091, E2092 and E2093 concurrently.

TRAN.TRI.PHA

N.1259782909

Digitally signed by

TRAN.TRI.PHAN.1259782909

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=TRAN.TRI.PHAN.1259782909 Date: 2017.01.26 13:51:47 -06'00'

FERGUSON.WA

DE.RANDALL.13

79892597

Digitally signed by

FERGUSON.WADE.RANDALL.1379892597

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=CONTRACTOR, cn=FERGUSON.WADE.RANDALL.137989259 Date: 2016.12.12 08:01:35 -06'00'

Wade Ferguson

NOLL.GERALD.S

TEVEN.12311769

Digitally signed by

NOLL.GERALD.STEVEN.1231176922

DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USA, cn=NOLL.GERALD.STEVEN.1231176922 Date: 2017.01.26 15:11:59 -06'00'

Tri Tran G Steve Noll PUBLICATION CHANGE REQUEST: REQUEST THAT THE FOLLOWING DATA BE INCLUDED IN THE NEXT

CHANGE OR REVISION TO THE PUBLICATION IDENTIFIED ABOVE.

WP NO. PAGE

NO.

PARA-

GRAPH

FIGURE/

TABLE

NO.

CHANGES

(EXACT WORDING OF CHANGES MUST BE GIVEN)

0009 00

0009 00

00-2

00-2

Table 0.0

REPLACE: "IUID DATA PLATES and steps 1 thru 5" with new " DoD IUID REGISTRY QUERY" found on pages 2 and 3 of this MEO.

INSERT: "Table 0.0 IUID Life Cycle Event Table" Before "Table 1 Preshop Analysis Checklist for Primary Manifold P/N 266500."

Distribution Statement D:- Distribution authorized to Department of Defense and U.S. DoD contractors only to protect critical technology effective as of 26 June 2014. Other requests for this document must be referred to U.S. Army Aviation and Missile Research, Development and Engineering Center, ATTN: RDMR -AEM , Corpus Christi, TX 78419-5211

MED FORM 30 AUG 2016

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

DOD IUID REGISTRY QUERY

Inspect the Primary (WP 0018 00, Figure 1) and Utility (WP 0064 00, Figure 1) accessory system manifolds for the presence of a 2-D data matrix via an IUID data plate, OPM IUID data plates (WP 0018 00, Figure 2 and WP 0064 00, Figure 2) or other IUID label media.

NOTE

Do not remove IUID data plate(s) unless necessitated by damage, maintenance requirements or determination that the item does not meet the criteria below.

If the Primary or Utility Hydraulic System Accessories Manifolds arrive with an IUID data plate other than what is depicted in (WP 0018 00 Figure 1, Figure 2 or WP 0064 00 Figure 1, Figure 2) contact cognizant AMRDEC engineering or contracting officer representative (COR) for replacement instructions.

1. If no 2-D data matrix is present, query the DoD IUID Registry via the Wide Area Work Flow (WAWF) (WP

0144 00, WEBSITES) and/or US Army Aviation and Missile Command (AMCOM), The Army Maintenance Management System - Aviation/Maintenance Consolidated Database System (TAMMS-A/MCDS), Unique Identification (UID) database at https://tamms-a.redstone.army.mil, using legacy information (PN/SN) for a UII match to ensure there are no multiple UIIs or duplication. If there is no match, an UII shall be created using Construct 1 and Text Elements Identifiers (TEIs) SPL and UCN, IAW DoD Guide to Uniquely Identifying Items and/or MIL-STD-130, and register in the DoD IUID Registry via the WAWF or TAMMS-A/MCDS, UID database (WP 0144 00, WEBSITES). The UII can be constructed by the overhaul facility using the overhaul facility's CAGE Code (SPL) and assigned UCN; or the overhaul facility can request an UII from AMCOM (AMSAM-MMC-MA-NM); or generate an UII via the TAMMS-A/MCDS, UID database (WP 0144 00, WEBSITES).

2. If a 2-D data matrix is present, scan/read data matrix using a handheld data matrix reader (WP 0014 00, Table 1, Item 52) or an equivalent. Using the scanned data query the DoD IUID Registry via the WAWF and/or TAMMS-A/MCDS, UID database (WP 0144 00, WEBSITES). If the registry and/or UID database returns a record, record data and all pertinent information required to reconstruct the 2-D data matrix and IUID data plate (UII, HRI, PN, information on the data plate...). It is necessary that the UII and recorded data be matched to the same Primary or Utility Hydraulic System Accessories Manifolds found during in-process inspection.

WARNING

ISOPROPYL ALCOHOL, TECHNICAL

3. If a 2-D data matrix is present and cannot be read after two attempts, clean the 2-D data matrix with a clean cloth (WP 0157 00, Item 4) moistened with isopropyl alcohol (WP 0157 00, Item 24) and scan/read again. If the 2-D data matrix cannot be read, using the HRI combination of the Enterprise Identifier (MFR, 7L or SPL), Serial Number (SER or S) or Unique Component Number (UCN), as applicable, query the DoD IUID Registry via the WAWF and/or TAMMS-A/MCDS, UID database (WP 0144 00, WEBSITES). If the registry and/or UID database returns a record, record data and all pertinent information required to reconstruct the 2-D data matrices and IUID data plate (UII, HRI, PN, information on the data plate...). It is necessary that the UII and recorded data be matched to the Primary or Utility Hydraulic System Accessories Manifolds found during in-process inspection.

MED FORM 24 FEB 2016

Attac2090

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

4. If there is no recorded UII in the DoD IUID Registry and/or TAMMS-A/MCDS, UID database, create an UII in accordance with Step 1. Refer to (WP 0018 00, Primary or WP 0064 00, Utility) for IUID data plate replacement.

The verification for minimum print quality grade applies to compliant IUID data plates that have been removed and will be reapplied. For components having an compliant IUID data plate that is installed (is not being removed during the M&O event), the IUID data plate can remain on the component provided the 2-D data matrix passes a readability check per WP 0018 00, (Primary) Aluminum IUID Data Plate Application, Step 7 or WP 0064 00, (Utility) Aluminum IUID Data Plate Application, Step 7.

5. If the IUID data plate requires removal, record all data for the replacement of the 2-D data matrix. If reinstalling the same IUID data plate, using a grader (WP 0014 00, Table 1, Item 53) or an equivalent, ensure the MRI has a minimum print quality passing grade per parameters specified in MIL-STD-130. As an exception, the grading requirements for verification of laser etch black anodized aluminum plates can be per WP 0018 00, Table 1. Replace any IUID label media that doesn't meet the MRI minimum grade requirements. All data recorded shall be matched to the same Primary or Utility Hydraulic System Accessories Manifolds found during in-process inspection or registry query. Continue component through the M&O process until the Primary or Utility Hydraulic System Accessories Manifolds are ready for IUID marking. Refer to WP 0018 00 (Primary) or WP 00664 00 (Utility)for IUID data plate replacement.

IUID LIFE CYCLE EVENT (LCE)

A life cycle event specific to UID compliance is any change to the permanent status of an item i.e., lost, stolen, destroyed…, that the DOD Guide to Uniquely Identifying Items requires be reported to the DOD IUID registry.

If applicable, report to the DoD IUID Registry via the WAWF (WP 0144 00, WEBSITES) or TAMMS-A/MCDS, UID database at https://tamms-a.redstone.army.mil, the item's change of permanent status if one of the life cycle events listed in Table 0.0 occur.

IUID PARENT CHILD RELATIONSHIP

A parent item is an assembly, intermediate component or subassembly that has an embedded item with an UII or DoD recognized UII equivalent. If applicable, upon completion of the M&O event, report component parent child relationship updates to the DoD IUID Registry via the WAWF (WP 0144 00, WEBSITES) or TAMMS-A/MCDS, UID database at https://tamms-a.redstone.army.mil.

PART NUMBER CONFIGURATION CHANGE

If required, upon completion of the M&O event, the component part number configuration changes (part number roll/dash number change) that would require an addition or update to the PNR or 30P (current part number), the configuration change shall be reported to the DoD IUID Registry via the WAWF (WP 0144 00, WEBSITES) or TAMMS-A/MCDS, UID database at https://tamms-a.redstone.army.mil.

MED FORM 24 FEB 2016

Continuation Sheet

MEO NO.

PAGE of

MED FORM 15-DEC-09 1401-R-E

TABLE 0 IUID LIFE CYCLE EVENTS

IUID LIFE CYCLE EVENTS (LCE)

Event Definition

Abandoned

Property surrendered by a Federal agency after a written determination that the property has no commercial value, or the estimated cost of its continued care and handling would exceed the estimated proceeds from its sale. An item has no commercial value when it has neither utility or monetary value (either as useable property or as scrap)

Consumed Non-reversibly incorporated into another item

Destroyed – Accident Destroyed during a fire, natural disaster, or other unplanned natural or man-made incident

Destroyed – Combat Destroyed by the enemy during combat

Donated

Surplus property provided to a Service Educational Activity; a State, political subdivision, municipality, or tax-supported institution acting on behalf of a public airport; a public agency; a public body; a charitable institution; or any State or local government agency, and certain nonprofit organizations or institutions

Exchanged – Sold Provided to a supplier for credit Exchanged – Repair Provided to a supplier for an equivalent replacement part Exchanged – Warranty

Provided to a supplier for an equivalent replacement part or credit while under warranty

Expended – Normal Use

Such as in the firing of a missile during combat or consumed during a manufacturing process

Expended – Experimental/Target

Such as the firing of a missile during training exercises and for testing; items destroyed while serving as a target during training exercises and tests

Leased Property that is granted to a lessee for a period of time in exchange for rent or other consideration

Loaned Owned by a DoD component and loaned to contractors, scientific institutions or other organizations

Lost Property that cannot be located or otherwise accounted for Reintroduced When an item is returned to DoD service

Retired Withdrawn from normal service; taken out of use. Includes decommissioned, stricken, sunken, transferred to AMARC/DRMS, etc.; excludes temporary idling of the item

Scrapped Waste material that will not be reused or reprocessed Sold – Other Federal Title transferred to non-DoD Federal Agencies with compensation

Sold – State/Local Title transferred to non-Federal governmental entities with compensation

Sold – Foreign Govt. Title transferred to non-US governmental entities with compensation

Sold – Non-Govt. Title transferred to non-governmental entities such as churches, organizations, etc. with compensation

Sold – Historic Title transferred to a museum or similar entity with compensation Stolen Lost via theft

MED FORM 24 FEB 2016