Solicitation # W56HZV-19-Q-0082
Attachment 0003
UNCLASSIFIED
Company ______________________ CAGE Code _____________ POC Name ____________
POC Telephone ____________________ POC E-Mail ________________________________
Medium Caliber Weapon System (MCWS) Design – Technical Information Questionnaire (TIQ)
The intention of this TIQ is to determine whether your proposed MCWS design is technically acceptable. For each requirement listed below, you must indicate whether you meet it via an “X” in the “Meets” or “Does Not Meet” columns. You must provide the required evidence, detailed in the below table, that clearly shows how you will meet each requirement.
Failure to provide an adequate response to any below requirement may result in your proposal being determined to be Unacceptable or rejected. Additionally, any response that reveals that your proposal does not meet any program requirement, not just those requirements listed below, may result your proposal being determined to be Unacceptable or rejected.
Definitions
CAD Model Images – screen captures of 3D CAD models showing overall assembly.
Interface Control Document (ICD) - provides a record of all interface information (such as drawings, diagrams, tables, and textual information) generated for a project. The underlying interface documents provide the details and describe the interface or interfaces between subsystems or to a system or subsystem.
Live Fire Test Report – document containing results from a lethality live fire event of proposed MCWS solution.
Two Dimensional Drawings – top level drawings of the system assembly including top, side and front views with dimensions in portable document format (pdf).
Solicitation # W56HZV-19-Q-0082
Attachment 0003
UNCLASSIFIED
Contractor’s Signature____________________________ Date____________________
Item
Meets
Req.
Does
Not
Meet
Req.
Requirement Required Evidence
MCWS Design shall accept and fire 30x173mm suite of ammunition (including airburst rounds).
Interface Control Document
(ICD)
MCWS Design integrated with ICVVA1 shall be transportable in a C-17 (142 inches x 204 inches).
CAD models images and 2D drawings, ICD
MCWS Design mounting solution shall not exceed
2,500 mm in diameter.
CAD models images and 2D drawings, ICD
MCWS Design shall be unmanned/remote operable. CAD models images and 2D drawings, ICD
The contractor shall have test fired the MCWS (20mm
– 40mm) on a vehicle or stand.
Live fire test report
MCWS Design shall have a dual feed ammunition handling system capable of maintaining at least two types of ammunition (MK238 Mod 1, MK258 Mod 1, MK239, and MK317).
CAD models images and 2D drawings, ICD
File details come from the government source that posted it.