This document provides scaffolding requirements for CVN 68. The requirements specify that scaffolding must be a minimum of 3 feet and maximum of 5 feet from the base of the Launcher. An additional level of scaffolding is required at 6.5 feet to allow workers to reach higher parts, while allowing doors to fully open. The roof needs to be a minimum of 6.5 feet above the second level, totaling approximately 13 feet in height. Distances and heights must also be maintained on sides where possible.
The related federal contract opportunity is a solicitation from the Department of the Army for scaffolding services at 3 different locations in the United States. Offerors should refer to the Performance Work Statement and attachments for complete details. Any questions should be directed to the Contract Specialist via email by the completion date.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W51AA124Q00410002.pdf | ||
| W51AA124Q00410001.pdf | ||
| (Attachment 2) SCAFFOLDING FRAME CVN 68.pdf | ||
| (Attachment 5) Scaffolding Requirememts LPD 24_ LPD 23.pptx | PPTX presentation | |
| (Attachment 1)OSRP SOW CVN 68.pdf | ||
| W51AA124Q0041.pdf | ||
| (Attachment 4) SCAFFOLDING FRAME LPD 24_LPD 23.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scaffolding Requirements Note: Pictures and dimensions are not drawn to scale
Scaffolding Distance/Height
The scaffolding needs to be a minimum of 3 ft away from the base of the Launcher with a max of 5 ft where possible.
3 ft – 5 ft 3 ft – 5 ft Not drawn to scale
This 3’-5’ distance needs to be maintained up to a 6 1/2 ft height from the ground to give the Team enough working space.
6 ½ ft
At 6 1/2 ft, there needs to be another level of scaffolding made for the workers to stand on in order to work on the higher parts of the Launcher. This second level must be far enough away so the doors can be fully opened .
3 ½ ft 3 ½ ft
From the second level, the roof would need to be a minimum of 6 1/2 ft above this level for the team to be able to work on the second level. This would give a total height of at 13 ft from the ground to the top of the enclosure.
Min 6 ½ ft Min 6 ½ ft
3 ft – 5 ft 6 ½ ft 1ft-2ft Min 6 ½ ft The same distances and heights need to be maintained on the sides also, where possible. It is obvious the distances will be maintained on the left side. Ideally, get as close to these distances as possible on the left side near the wall.
image1.jpeg image2.jpeg