(Attachment 5) Scaffolding Requirememts LPD 24_ LPD 23.pptx

PPTX presentation 957 KB Posted

Attached to
Scaffolding Services Federal contract opportunity
Solicitation number
W51AA124Q0041
Issued by
Department of the Army

About this file

This document provides requirements for scaffolding services to be provided at three locations for the Department of the Army. The scaffolding must be installed between 3 to 5 feet from the base of the launchers up to a height of 7 feet, with a second level between 1 to 2 feet away at heights above 7 feet up to a total height of 15 feet. The scaffolding distances must be maintained on all sides where possible. Electrical outlets and an air compressor delivering 110 CFM of power are also required. Interested parties should review the performance work statement in solicitation number W51AA124Q0041 and submit a completed solicitation to Contract Specialist Dean Berkovics at Dean.M.Berkovics.civ@army.mil by the response date specified.

View the file

Other files for this federal contract opportunity

Other files attached to Scaffolding Services, newest first.
File Type Posted
W51AA124Q00410002.pdf PDF
W51AA124Q00410001.pdf PDF
(Attachment 1)OSRP SOW CVN 68.pdf PDF
W51AA124Q0041.pdf PDF
(Attachment 4) SCAFFOLDING FRAME LPD 24_LPD 23.pdf PDF
(Attachment 3) Scaffolding Requirements CVN 68 .pptx PPTX presentation
(Attachment 2) SCAFFOLDING FRAME CVN 68.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Scaffolding Requirements Note: Pictures and dimensions are not drawn to scale

Scaffolding Distance/Height

The scaffolding needs to be a minimum of 3 ft away from the base of the Launcher with a max of 5 ft where possible.

3 ft – 5 ft 3 ft – 5 ft Not drawn to scale

This 3’-5’ distance needs to be maintained up to a 7 ft height from the ground to give the Team enough working space.

7 ft 7 ft

At 7 ft, there needs to be another level of scaffolding made for the workers to stand on in order to work on the higher parts of the Launcher. This second level must be a minimum of 1ft – 2ft from the Launcher.

1ft-2ft 1ft-2ft

From the second level, the roof would need to be a minimum of 8 ft above this level for the team to be able to work on the second level. This would give a total height of at 15 ft from the ground to the top of the enclosure.

Min 8ft Min 8ft

3 ft – 5 ft 7 ft 1ft-2ft Min 8ft The same distances and heights need to be maintained on the sides also, where possible. It is obvious the distances will be maintained on the left side. Ideally, get as close to these distances as possible on the left side near the wall.

Air compressor - 110 CFM Power- Electrical Outlets- Standard 110

Other Requirements image1.jpeg image2.jpeg