Tab 4 Specifications.pdf
PDF 1 MB Posted
- Solicitation number
- 80NSSC872228Q
About this file
This document appears to be a set of technical specifications and drawings related to the fabrication of an electrical component altitude chamber. The specifications include dimensions, fabrication requirements, and interface details for the test chamber and equipment platform. The related federal contract opportunity is a solicitation from NASA GRC for the fabrication of this altitude chamber, which is set aside for small businesses. The solicitation includes a Statement of Work, Specifications, and Request for Quote, with delivery to the NASA Armstrong Test Facility in Sandusky, Ohio. The contract will be awarded by government purchase order, and offerors must be registered in SAM.gov to be considered. Partial quotes will not be accepted.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Tab 12 RFQ 80NSSC872228Q.pdf | ||
| Tab 12 Q A.pdf | ||
| Tab 12 RFQ 80NSSC872228Q.pdf | ||
| Tab 12 RFQ 80NSSC872228Q.pdf | ||
| Tab 4 SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B B
2345678
12345678
C
D
E
F
G
H
A
B
C
D
E
F
G
H
CHG NUM DESCRIPTION
REVISIONS
PR
O
PE
R
TY
O
F U
N
IT
ED
S
TA
TE
S G
O
VE
R N
M
EN
T
- F
O R
O
FF
IC
IA
L U
SE
O
N
LY
D o no t r em ov e th is n ot ic e.
P ro pe rly d es tro y do cu m en t w he n no lo ng er n ee de d.
2311_TFA_SOW_ALT_CHAMBER_ASSY
B
E_fed_atf.frm 2021-3-30
INTERIOR WIDTH
OVERALL
HEIGHT
OVERALL
DEPTH
DIMESIONS ARE SHOWN FOR
GENERAL CONFIGURATION ONLY.
TEST CHAMBER FABRICATION
CONFIGURATION SHOWN IS GENERAL
IN LAYOUT AND NOT MEANT TO DEFINE
SPECIFIC DESIGN REQUIREMENTS.
REFER TO THE STATEMENT OF WORK
FOR ALL SPECIFICS REGARDING TEST
CHAMBER ENGINEERING REQUIREMENTS.
3.
2.
1.
DIMENSIONING AND
TOLERANCING PER
ASME Y14.5M-1994
BREAK EDGES
0.50ANGULAR
-FRACTION
0.005.XXX
0.01.XX
0.03.X
TOLERANCE ON
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
2-XX/XX/XXXXOFFICIAL DATE:1/20SCALE:
VERREVCREOSOFTWARE:ENGLISHUNITS:
DATE:RELEASE APPROVAL:APPROVAL DATEAPPROVED
XXXXCMGCMG
1 OF 1SHEETGRC-ATFAREA:DATE:RELEASE APPROVAL:CHECKEDDESIGNEDDRAWN
C01M- -00033146- 2311PECONCEPTUAL
RELEASE STATUS:TASK ORDER
TYPE SEQDISCPPROJECT IDBLDG/SYSSIZEJ. CONNELLYA. DIMSTONNNC15BA02B
ALTITUDE CHAMBER CONCEPTUAL LAYOUT
PROJ. MGR:D. ENG:CONTRACT NO.
CMGCMGTFOME
DES:DR:CONTRACTOR
D-SITE
CONFIG:FACILITY:SUB_SYS:SYSTEM:
BLDG. 2311 - D-SITE - ARMSTRONG TEST FACILITY
ARMSTRONG
TEST FACILITY
6100 COLUMBUS AVENUE
SANDUSKY, OHIO
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION
JOHN H. GLENN RESEARCH CENTER
LEWIS FIELD
CLEVELAND, OHIO
CAD DRAWING - DO NOT REVISE MANUALLYNOT DESIGNATED
NOT DESIGNATED
SECTION B-B
FRONT VIEW
BACK VIEW
FRONT VIEW
LEFT SIDE VIEW RIGHT SIDE VIEW
(2) 8" CLASS 150# FLANGES
WITH BLIND TAPPED HOLES
0N TEST CHAMBER CENTERLINE
FOR MECHANICAL INTERFACES
(4) ISO 400 K FLANGES FOR
ELECTRICAL/INSTRUMENTATION
INTERFACES
ISO 250 K FLANGE
FOR AUXILLIARY INTERFACE
SECTION C-C
TOP VIEW
ISO 160 K FLANGE
FOR TEST CHAMBER
VACUUM CONNECTION
ISOMETRIC VIEW - FRONTISOMETRIC VIEW - BACK
FULL SIZE TEST CHAMBER DOOR
2345678
12345678
C
D
E
F
G
H
A
B
C
D
E
F
G
H
B
CHG NUM DESCRIPTION
REVISIONS
PR
O
PE
R
TY
O
F U
N
IT
ED
S
TA
TE
S G
O
VE
R N
M
EN
T
- F
O R
O
FF
IC
IA
L U
SE
O
N
LY
D o no t r em ov e th is n ot ic e.
P ro pe rly d es tro y do cu m en t w he n no lo ng er n ee de d.
2311_TURBINE_FACILITY_ASSY
E_fed_atf.frm 2021-3-30
1' 8-5/8"
21' 5-1/4"
~1'
4' 9"
6'
5' 11-3/4"
22' 4-3/4"
38' 9-3/8"
6'
6'
(9' )
(4' 9")
(35' ) (9' 6")
REFER TO HENRY GURTZWEILER INC.
CONTRACTOR DRAWING R00, REV 1 FOR
DETAILS OF THE FOOTING LAYOUT,
REINFORCING STEEL AND INSTALLATION
REQUIREMENTS.
1.
DIMENSIONING AND
TOLERANCING PER
ASME Y14.5M-1994
-BREAK EDGES
0.50ANGULAR
1/16FRACTION
0.005.XXX
0.01.XX
0.03.X
TOLERANCE ON
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
1-XX/XX/XXXXOFFICIAL DATE:7/1000SCALE:
VERREVCREOSOFTWARE:ENGLISHUNITS:
DATE:RELEASE APPROVAL:APPROVAL DATEAPPROVED
XXXXCMGCMG
1 OF 1SHEETGRC-AFTAREA:DATE:RELEASE APPROVAL:CHECKEDDESIGNEDDRAWN
101S- -00200177- 2311PEPRELIMINARY 5/6/24
RELEASE STATUS:TASK ORDER
TYPE SEQDISCPPROJECT IDBLDG/SYSSIZEJ. CONNOLLYC. WEEDERNNC15BA02B
EQUIPMENT PLATFORM
FOUNDATION LOCATIONS
PROJ. MGR:D. ENG:CONTRACT NO.
CMGCMGTFOME
DES:DR:CONTRACTOR
D-SITE
CONFIG:FACILITY:SUB_SYS:SYSTEM:
BLDG. 2311 - D-SITE - ARMSTRONG TEST FACILITY
D-SITE FACILITY DEVELOPEMENT
ARMSTRONG
TEST FACILITY
6100 COLUMBUS AVENUE
SANDUSKY, OHIO
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION
JOHN H. GLENN RESEARCH CENTER
LEWIS FIELD
CLEVELAND, OHIO
CAD DRAWING - DO NOT REVISE MANUALLYNOT DESIGNATED
NOT DESIGNATED
NORTH
SECTION PLAN-PLAN
SCALE 1/40
PLAN VIEW - EQUIPMENT PLATFORM FOUNDATION LOCATIONS
EXISTING 54" DEEP
BED PLATE
(6) NEW 18" DEEP
PLATFORM FOOTINGS
| PR4200872228 Spec 1 |
| Sheet 1 |
| Views |
| new_view_1 |
| left_2 |
| left_3 |
| top_4 |
| right_5 |
| new_view_6 |
| new_view_7 |
| Zones |
| H8 |
| H7 |
| H6 |
| H5 |
| H4 |
| H3 |
| H2 |
| H1 |
| G8 |
| G7 |
| G6 |
| G5 |
| G4 |
| G3 |
| G2 |
| G1 |
| F8 |
| F7 |
| F6 |
| F5 |
| F4 |
| F3 |
| F2 |
| F1 |
| E8 |
| E7 |
| E6 |
| E5 |
| E4 |
| E3 |
| E2 |
| E1 |
| D8 |
| D7 |
| D6 |
| D5 |
| D4 |
| D3 |
| D2 |
| D1 |
| C8 |
| C7 |
| C6 |
| C5 |
| C4 |
| C3 |
| C2 |
| C1 |
| B8 |
| B7 |
| B6 |
| B5 |
| B4 |
| B3 |
| B2 |
| B1 |
| A8 |
| A7 |
| A6 |
| A5 |
| A4 |
| A3 |
| A2 |
| A1 |
| PR4200872228 Spec 2 |
| Sheet 3 |
| Views |
| new_view_5 |
| Zones |
| H8 |
| H7 |
| H6 |
| H5 |
| H4 |
| H3 |
| H2 |
| H1 |
| G8 |
| G7 |
| G6 |
| G5 |
| G4 |
| G3 |
| G2 |
| G1 |
| F8 |
| F7 |
| F6 |
| F5 |
| F4 |
| F3 |
| F2 |
| F1 |
| E8 |
| E7 |
| E6 |
| E5 |
| E4 |
| E3 |
| E2 |
| E1 |
| D8 |
| D7 |
| D6 |
| D5 |
| D4 |
| D3 |
| D2 |
| D1 |
| C8 |
| C7 |
| C6 |
| C5 |
| C4 |
| C3 |
| C2 |
| C1 |
| B8 |
| B7 |
| B6 |
| B5 |
| B4 |
| B3 |
| B2 |
| B1 |
| A8 |
| A7 |
| A6 |
| A5 |
| A4 |
| A3 |
| A2 |
| A1 |
Spec 3
File details come from the government source that posted it. Updated .