SP_Tennis_Rehab_2025_Rev3.pdf

PDF 2 MB Posted

Attached to
Schenley Park Tennis Courts Upgrades
Solicitation number
2025-IFB-236
Issued by
Allegheny County, Philadelphia City, Pennsylvania

About this file

The document is a Scope of Work for the North Schenley Park Tennis Courts project by the City of Pittsburgh Department of Public Works, located at 1 Overlook Drive, Pittsburgh, PA. The project involves comprehensive renovation of tennis courts 8-13, including base bid work such as removing existing asphalt, repaving, installing tennis posts, and resurfacing courts in light green and light blue. Multiple add-alternate options are provided, including subbase repair, installing player and city standard benches, converting one tennis court to four pickleball courts, replacing the drinking fountain, and installing trash receptacles.

The base bid and alternate work specifications are detailed with precise requirements for materials, installation, and post-construction restoration. Specific requirements include using SportMaster Sport Surfaces products, Douglas Premier RD-36 Pickleball/QuickStart Tennis Posts, and ensuring all trees on site are protected. The contractor will be responsible for hauling and disposing of stripped materials, repairing any damages to existing courts or park features, and reseeding and maintaining disturbed areas until grass is fully established. The project is scheduled for completion by 7/31/2025, with a project number of 2025-88506.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Department of Public Works

NORTH

SC

H

EN

LE

Y

PA

R K

TE

N

N

IS

C O

U R

TS

O ve rlo ok D riv e, P itt sb ur gh , P

A

2025-88506

City of Pittsburgh

NTS

7/31/2025

SCOPE OF

WORK

L-1 1 4

BASE BID SCOPE OF WORK

COURTS 8-13:

1. Remove and store fencing as needed to allow machinery access to courts, and reinstall after completion.

2. Demolish existing asphalt.

3. Repave asphalt per detail.

4. Furnish and install set of tennis posts (6) per attachment.

Edwards 3"

5. Resurface (2 colors) and stripe tennis courts per existing layout.

ADD ALTERNATES

COURTS 8-13:

Add-alt 1: Repair / replace subbase as needed, per detail.

Add-alt 2: Furnish and install city player benches (6) per detail.

Add-alt 3: Furnish and install city standard benches (2) per detail.

COURT 8:

Add-alt 4: Convert one existing tennis court into 4 pickleball courts, including resurfacing, stripping, posts, nets, and fencing. Bench and gate layout may need to be modified if chosen. Furnish and install tennis posts. Use Douglas Premier RD-36 Pickleball / QuickStart Tennis Posts and Douglas nets or approved equals.

DRINKING FOUNTAIN:

Add-alt 5: Furnish and install city standard drinking fountain to replace existing fountain, per detail.

Add-alt 6: Furnish and install SD-42 pair of trash receptacles (Black & Blue). Include the Dom Top Lid for recycle receptacle per attachment. Location TBD per Project Manager

NOTES:

Repave and resurface color coating on all tennis courts per existing layout.

Use SportMaster Sport Surfaces products in light green and light blue. See Washington's Landing tennis / pickleball courts for example.

All trees on site MUST BE PROTECTED. Contractor will be liable for any damages to trees.

Contractor to haul and dispose of all stripped and unusable materials.

Contractor to repair any damages to existing courts, walkways, or other park features that may occur during construction.

Contractor shall reseed all disturbed areas and provide maintenance until the grass is fully established

AutoCAD SHX Text Revisions

AutoCAD SHX Text Project Address

AutoCAD SHX Text Project Title

AutoCAD SHX Text Project No.

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Date

AutoCAD SHX Text Scale

AutoCAD SHX Text Sheet No.

AutoCAD SHX Text of

10'

5'

5'

8'

8'

8'

8'

300'

36' 36' 36' 36' 36' 36' 12'12' 12'12' 12' 12' 12'

120'78'

Department of Public Works

SC

H

EN

LE

Y

PA

R K

TE

N

N

IS

C O

U R

TS

O ve rlo ok D riv e, P itt sb ur gh , P

A

2025-88506

City of Pittsburgh

NTS

7/31/2025

COURT

DETAILS

L-2 2 4

COURTS 8-13 BENCH PAD LOCATIONS:

6 player bench pads within the courts to be located as shown, in between courts 1&2, 3&4, 5&6 on both sides, and at the middle of the courts on both ends 8" x 2.5"

COURT 8:

Add-alt 4: Convert one existing tennis court into 4 pickleball courts, including resurfacing, stripping, posts, nets, and fencing.

Bench and gate layout may need to be modified if chosen.

Furnish and install tennis posts. Use Douglas Premier RD-36 Pickleball / QuickStart Tennis Posts and Douglas nets or approved equals.

Pickleball Standard 30' x 60'

INSTALL NEW FENCE

TO DIVIDE PICKLEBALL

FROM TENNIS. APPROX.

106' LENGTH. 6' HEIGHT.

A 7' SPACE IN EACH

CORNER

INSTALL NEW FENCE

TO DIVIDE PICKLEBALL

COURTS. APPROX.

50' LENGHT. 6' HEIGHT

AutoCAD SHX Text Revisions

AutoCAD SHX Text Project Address

AutoCAD SHX Text Project Title

AutoCAD SHX Text Project No.

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Date

AutoCAD SHX Text Scale

AutoCAD SHX Text Sheet No.

STRIP EXISTING

LAYER(S) OF

BITUMINOUS PAVING

EXISTING SUBBASE

TO REMAIN (WHERE

APPLICABLE)

EXISTING SUBGRADE

EXISTING SURFACE

LIQUID APPLIED ACRYLIC SURFACE SYSTEM

(CUSHIONED OR NON-CUSHIONED)

1-1/2" MIN. WEARING COURSE, PENNDOT

SUPERPAVE 9.5mm OR APPROVED EQUAL

1-1/2" - 2" MIN. LEVELING / BINDER COURSE,

PENNDOT SUPERPAVE 19mm OR APPROVED EQUAL

6" MIN. COMPACTED PENNDOT 2A BASE COURSE -

RESTORATION DEPTH SHALL VARY. FURNISH AND

INSTALL SUBBASE AGGREGATE AS FIELD REQUIRED

FOR GRADING AND COMPACTION PURPOSES, TO

ACHIEVE PROPER ELEVATIONS, AND/OR REPLACE

EXISTING SUBBASE MATERIAL INADVERTENTLY

REMOVED DUE TO ADHERENCE TO BINDER. ROLL

AND COMPACT SUBBASE THOROUGHLY.

PROPOSED SURFACE

UNDISTURBED

SUBGRADE

CD-1

STRIPPING AND RESURFACING BITUMINOUS TENNIS COURT

N.T.S.

TACK

COATS

4" DEPTH CONCRETE

WITH BROOM FINISH

WELDED WIRE MESH

4" AGGREGATE

SUBBASE

COMPACTACTED

SUBGRADE

CONCRETE PAVING - 4"

N.T.S.

EXPANSION &

SCORING JOINT

5' SPACING

ATTACH BENCH TO

CONCRETE WITH 12" DIA. X

4" LONG ANCHOR BOLTS,

TYP. PAINT BOLT HEAD

TO MATCH BENCH

ADJACENT

SURFACE

CONCRETE PAVING,

BROOM FINISH.

COMPACTED

SUBGRADE

CONCRETE BENCH PAD

N.T.S.

6' TYP. 2.5' TYP.

CD-1

CD-1

FRONT

BACK

2'-9"

2"

1'-95 8"

Fasteners for standard assembly

Size Type 6' Bench

4-20 x 58" Button Socket Cap Screw 3

4-20 x7

8" Button Socket Cap Screw 12

4-20 12" Sex Bolts 9

4-20 x1" Sex Bolts 6

4-20 x1 12" Black Oxide Carrage Bolts 27

4-20 Acorn Nuts 27

16" Flat washers 27

4-20 x 1" Black Oxide Rnd head machine screw & nut 2

4-20 x 1" Hex Head bolt 1

214"

5'-117 8"

NOTES:

1. INCLUDED: (1) 3 34" X 1 14"X 72" AND (7) 2 12" X 1 14" X 72" WOODEN SLATS.

2. SLATS TO BE CLEAR WHITE OAK WITH BEVELED EDGES. WOOD FINISH: NONE

3. FRONT SLAT TO HAVE RADIUS AT FRONT EDGE AND BEVELED REAR EDGE.

4. SLATS TO BE CLEAR OF KNOTS AND DISFIGURATIONS AND UNSIGHTLY BLEMISHES, COMPLETELY SANDED.

6. SPACE HARDWARE HOLES FOR SEAT SLATS TO ALLOW FOR APPROPRIATE DRAINAGE.

8. METAL PRIMER: SHERWIN WILLIAMS, KEM BOND HS, RED OXIDE, B50 NZ 3, 630-4521

9. METAL FINISH: JANOVIC GLOSS ALKYD, DIAMOND-LIKEÔ HIGH PERFORMANCE ENAMEL, GLOSS BLACK 9764 (POLYURETHANE EPOXY).

10. BENCHES MANUFACTURED BY ARCHITECTURAL IRON COMPANY OR APPROVED EQUAL

11"11 2"

2"

8"

8"

2"

1"

SIDE Elevation (from Left-hand side)

1'-93 8"21

8" 1'-8"

ALT. # 3 - CITY OF PITTSBURGH 6' BENCH

N.T.S.

CD-1

27"

54"

34"

4"

5"

WATER

BOTTOM FILLER

4" SCHEDULE 40 PVC DRAIN

SLOPE TO DRAIN

NOTES:

1. FOUNTAIN SHALL BE BLUE COLOR MODEL MDF 10155 SM WITH PET FOUNTAIN AS

MANUFACTURED BY MOST DEPENDABLE FOUNTAINS, OR APPROVED EQUIVALENT.

2. INCLUDE RECESSED HOSE BIB AND LOCKED DOOR.

3. MEETS ADA REGULATIONS.

4. INSTALL ACCORDING TO MANUFACTURER'S SPECIFICATIONS.

5. VERIFY LOCATIONS AND ORIENTATION WITH OWNER'S REPRESENTATIVE.

4" PVC WASTE LINE OR TRAP,

MIN. 1% SLOPE TO EXISTING

SANITARY LINE. DEPTH OF

TRAP AS FIELD DETERMINED

FOR PROPER DRAINAGE.

#2B AGGREGATE

DRY WELL,

2'X2'X2' DEPTH

3/4" COPPER SUPPLY LINE

MIN. 3' BURY, SLOPE TO

DRAIN VALVE.

VALVE BOX WITH VALVE

AND PLUGGED TEE FOR

DRAIN DOWN THICKENED

CONCRETE

HAUNCH 14" DEEP

1/2" x 12" ZINC PLATED ROD, TYP.

PET

FOUNTAIN

C/L

2",3" OR 4"

OPEN HUB DRAIN

10" PIPE

FILTER

OPTIONAL 10"

STAINLESS

STEEL CARRIER

PF ON

OPPOSITE SIDE

ACCESS DOOR

18"

BY MDF

11 3/4"

SLOPE TO DRAIN

ALT. #5 - DRINKING FOUNTAIN WITH BOTTLE FILLER AND PET BOWL

N.T.S.

CD-1

Department of Public Works

SC

H

EN

LE

Y

PA

R K

TE

N

N

IS

C O

U R

TS

O ve rlo ok D riv e, P itt sb ur gh , P

A

2025-88506

City of Pittsburgh

NTS

7/31/2025

CONSTRUCTION

DETAILS

CD-1

3 4

AutoCAD SHX Text Revisions

AutoCAD SHX Text Project Address

AutoCAD SHX Text Project Title

AutoCAD SHX Text Project No.

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Date

AutoCAD SHX Text Scale

AutoCAD SHX Text Sheet No.

NOTES:

1. ALL FABRICATED METAL COMPONENTS ARE STEEL SHOTBLASTED, ETCHED, PHOSPHATIZED, PREHEATED, AND

ELECTROSTATICALLY POWDER-COATED WITH T.G.I.C. POLYESTER POWDER COATINGS. PRODUCTS ARE FULLY CLEANED AND PRETREATED, PREHEATED AND COATED WHILE HOT TO FILL CREVICES AND BUILD FILM COATING.

COATED PARTS ARE THEN FULLY CURED TO COATING MANUFACTURER'S SPECIFICATIONS. THE THICKNESS OF

THE RESULTING FINISH AVERAGES 8-10 MILS (200-250 MICRONS).

2. PLASTIC INNER LINERS ARE MOLDED ON TOOLING DESIGNED FOR AND OWNED BY VICTOR STANLEY, INC.

3. PRODUCT MUST BE PERMANENTLY AFFIXED TO THE GROUND.

4. ANCHOR BOLT NOT PROVIDED BY VICTOR STANLEY, INC.

LIDS: S-2A DOME LID, WITH DECALS FOR RECYCLING CAN

SECURITY: MOUNT LID WITH 3 IN-LINE ANCHOR HOLES

AND BOTTOM PLATE COVER.

LITTER RECEPTACLE: MODEL SD-42, WITH S-2A DOME LID, COLOR BLACK, AS SUPPLIED BY VICTOR STANLEY, P.O.

DRAWER 330, DUNKIRK, MD 20754 USA, 1.800.368.2573 OR APPROVED EQUIVALENT.

RECYCLING RECEPTACLE: MODEL SD-42, WITH S-2A DOME LID AND RECYCLING DECALS, COLOR BLUE, AS SUPPLIED BY VICTOR STANLEY, P.O. DRAWER 330, DUNKIRK, MD 20754 USA, 1.800.368.2573 OR APPROVED EQUIVALENT.

Ø 28"

41-3/4"

38-5/8"

19"

36-GALLON CAPACITY HIGH

DENSITY PLASTIC LINER

(WEIGHT NOT TO EXCEED 6 LBS.)

SITS ON 3/8" x 3" SUPPORT BARS

(4) LEVELING FEET WITH 3/8" DIAMETER

THREADED STEEL SHAFT

5/8" SOLID

STEEL TOP

RING(42) 3/8" X 1"

VERTICAL

STEEL BARS

1/4" X 2-1/2"

HORIZONTAL

SOLID STEEL

BAND

3/4" SQUARE ANCHOR BOLT HOLES MOUNT

TO CONCRETE WITH TAMPER-PROOF BOLTS

PER MANUFACTURER'S RECOMMENDATIONS

ALT. # 6 TRASH AND RECYCLING RECEPTACLES

N.T.S.

CD.2

ALT. # 2 - PLAYER BENCH. MODEL DMTS 7.5 x 2 N.T.S.

CD.2

Department of Public Works

SC

H

EN

LE

Y

PA

R K

TE

N

N

IS

C O

U R

TS

O ve rlo ok D riv e, P itt sb ur gh , P

A

2025-88506

City of Pittsburgh

NTS

7/31/2025

CONSTRUCTION

DETAILS

CD-2

4 4

AutoCAD SHX Text Revisions

AutoCAD SHX Text Project Address

AutoCAD SHX Text Project Title

AutoCAD SHX Text Project No.

AutoCAD SHX Text Sheet Title

AutoCAD SHX Text Date

AutoCAD SHX Text Scale

AutoCAD SHX Text Sheet No.

Sheets and Views
L-1
SP Tennis Rehab 2025 Rev3-CD-1.pdf
Sheets and Views
CD-1
SP Tennis Rehab 2025 Rev3-CD-2.pdf
Sheets and Views
CD-2
SP Tennis Rehab 2025 Rev3-L-2.pdf
Sheets and Views
L-2
SP Tennis Rehab 2025 Rev3-L-1Rev.pdf
Sheets and Views
L-1
SP Tennis Rehab 2025 Rev3-L-2Rev.pdf
Sheets and Views
L-2
SP Tennis Rehab 2025 Rev3-L-1.pdf
Sheets and Views
L-1
SP Tennis Rehab 2025 Rev3-L-2.pdf
Sheets and Views
L-2

File details come from the government source that posted it. Updated .