SOW Attachments F-G.pdf

PDF 18 MB Posted

Attached to
Replacement of Overhead Doors - Solicitation
Solicitation number
W911QY-23-R-1024
Issued by

About this file

This document provides details on a federal solicitation for replacement of overhead doors. The solicitation number is W911QY-23-R-1024 and is being issued by the Department of the Army Materiel Command Army Contracting Command located at Aberdeen Proving Ground. The solicitation seeks to replace overhead doors at an unspecified location and requires bidders to provide pricing, installation details, warranties, and schedules for delivery and completion by the specified response date. Specific products or services required are not outlined, as the attached Statement of Work and additional file attachments were not provided for review.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

X

X X

X X

X X

X

X X X X X X X

X X

X X

X X

X X

X X X X X X X

X

X

U.S. ARMY NATICK

SOLDIER SYSTEM CENTER

10 General Greene Avenue, Natick, MA 01760

FOR PUBLIC DISTRIBUTION

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N11

AutoCAD SHX Text N12

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T-26

AutoCAD SHX Text T-27

AutoCAD SHX Text

AutoCAD SHX Text T-24

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TURNER STREET

AutoCAD SHX Text

TURNER STREET

AutoCAD SHX Text

RICH AVENUE

AutoCAD SHX Text

GREELY AVENUE

AutoCAD SHX Text

SAXTON STREET

AutoCAD SHX Text

EXIT RAMP

AutoCAD SHX Text

ENTRANCE RAMP

AutoCAD SHX Text

WILKIN AVENUE

AutoCAD SHX Text

DE CASTRO STREET

AutoCAD SHX Text

PRUSSMAN AVENUE

AutoCAD SHX Text

PINKHAM STREET

AutoCAD SHX Text

REGAN AVENUE

AutoCAD SHX Text

WILBUR AVENUE

AutoCAD SHX Text DeFRANZO SERVICE GATE

AutoCAD SHX Text

C LOT

AutoCAD SHX Text

M LOT

AutoCAD SHX Text

E LOT

AutoCAD SHX Text

D LOT

AutoCAD SHX Text

L LOT

AutoCAD SHX Text

I LOT

AutoCAD SHX Text

K LOT

AutoCAD SHX Text

J LOT

AutoCAD SHX Text

G LOT

AutoCAD SHX Text

H LOT

AutoCAD SHX Text

GENERAL GREENE AVENUE

AutoCAD SHX Text

KNOWLTON GATE

AutoCAD SHX Text

A LOT

AutoCAD SHX Text

AutoCAD SHX Text Lake Cochituate

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text #1

AutoCAD SHX Text

AutoCAD SHX Text

GREELY AVENUE

AutoCAD SHX Text

AutoCAD SHX Text

NO.

AutoCAD SHX Text

BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NO.

AutoCAD SHX Text

BUILDING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N12

AutoCAD SHX Text #1

AutoCAD SHX Text N11

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NO.

AutoCAD SHX Text

GRID

AutoCAD SHX Text

NO.

AutoCAD SHX Text

GRID

AutoCAD SHX Text G5

AutoCAD SHX Text G6

AutoCAD SHX Text E6

AutoCAD SHX Text E5

AutoCAD SHX Text E4

AutoCAD SHX Text F3

AutoCAD SHX Text E3

AutoCAD SHX Text E3

AutoCAD SHX Text E3

AutoCAD SHX Text C3

AutoCAD SHX Text C4

AutoCAD SHX Text C4

AutoCAD SHX Text C6

AutoCAD SHX Text C2

AutoCAD SHX Text C6

AutoCAD SHX Text E1

AutoCAD SHX Text E1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F1

AutoCAD SHX Text G7

AutoCAD SHX Text G8

AutoCAD SHX Text H8

AutoCAD SHX Text C5

AutoCAD SHX Text B3

AutoCAD SHX Text I4

AutoCAD SHX Text G9

AutoCAD SHX Text G7

AutoCAD SHX Text E2

AutoCAD SHX Text F7

AutoCAD SHX Text C2

AutoCAD SHX Text E2

AutoCAD SHX Text E5

AutoCAD SHX Text C2

AutoCAD SHX Text C3

AutoCAD SHX Text E1

AutoCAD SHX Text E2

AutoCAD SHX Text F5

AutoCAD SHX Text C1

AutoCAD SHX Text E5

AutoCAD SHX Text E2

AutoCAD SHX Text C3

AutoCAD SHX Text C2

AutoCAD SHX Text G8

AutoCAD SHX Text G7

AutoCAD SHX Text G4

AutoCAD SHX Text C2

AutoCAD SHX Text E1

AutoCAD SHX Text E5

AutoCAD SHX Text E2

AutoCAD SHX Text F2

AutoCAD SHX Text G7

AutoCAD SHX Text C6

AutoCAD SHX Text G7

AutoCAD SHX Text C6

Luis.Martin1 Text Box Attachment F

Building 16 North End Wing Overhead Door Replacement

Scope of Work Attachment #13

Front of Bldg. 16.

East elevation.

Replace 1 doors

DEVCOM

Basic Research Lab Storage

Location of Bldg. 16 – North Wing Environmental Replace 1 doors at east elevation

Existing East Door - interior

• Insulated Metal Rolling – replace in kind

Existing East Door, Electric Motor Controls

• Up / Down / Stop --- New Similar

East Door Size

Inside Dims:

10’-7” Wide

10’-1” High

Outside Opening size

9’-11” wide

10’-0” high

• New doors will be motor operated

• Tie into existing electrical service

• GC Coordinate

GC field verify all dimensions and existing conditions.

Building 16 – North

Overhead Door Motor

Electric Power

Building 77 Overhead Door Replacement 2 Doors

North & South Similar

Scope of Work Attachment #9

Building 77 - North Elevation

Bldg. 77 (north is up)

Exterior Opening Size Width: 11’-11” Height: 9’-10”

South Door Bldg. 77

Match 2 Existing Doors:

North + South Similar

• Heavy duty, rolling steel metal, insulated overhead door with interior mount roll head, color grey.

• Existing operation is chain Pull.

• New operation shall be electrical motor, GC Coordinate elect service

Roll hood at Interior

Existing door is manually operated

Using a pull chain

Coordinate with existing ceiling height

Existing Door Mfr:

Overhead Door Co

Of Southeastern MA

145 Tosca Drive

Stoughton, MA 02072

781-828-4033

Attn: Thomas Cafaro

GC Provide both:

1) Pricing for a new electrical motor, installed, off adjacent electrical panel.

• GC responsible for all associated electrical design construction coordination with existing.

2) Provide alternate pricing to replace with manual operation, similar to existing.

• Note interior door size is larger than exterior door opening. Overlapping of materials in existing conditions

Existing pull chain shown to the right

Interior Door Size

Width: 12’-6” Height: 10’-4”

• Existing Door Jamb, front view

• Electrical Panel Board located to left of door at interior

• Existing Door Jamb, side view

• Self supporting Steel frame by GC, in a metal panel siding context, coordinate structural requirements, install details and coordination

• Existing Door header , form Interior, with roll hood

• Existing electrical Panel

• GC Coordinate electrical service to new OHD Motors

Building 86

Replacement

Scope of Work Attachment #11

Navy

New door will be located at the lower level of Bldg. 86 facing the Lake

Door Lower Level

Existing over door is segmented panels. The exterior appearance is that of a rolling overhead door. New Door, similar

Existing motor; ceiling mounted. New motor, similar. Protect light fixture and ceiling during work.

• Clg. Ht.: 8’-2”.

• Coordinate above ceiling connections etc.

Existing track is ceiling and wall mounted.

New track, similar

• Overhead Door to be replaced at Bldg.

86, Navy.

• Interior Door Size Dimensions:

• 9’-2” width

• 7’-2” height

• GC field verify all dimensions and existing conditions. Provide secure closure at end of workday. Coordinate with Owner Rep to clear arear of work.

• Existing opening to remain, remove door and frame – replace with new. Protect gate and ladder during work.

Jamb & Sill Left Jamb & Sill RightDoor Header

• Overhead Door is located within and existing metal frame.

• Frame with a frame. Door frame opening size at exterior: 8’-10” wide x 6’-11” high

• Overall framed opening includes adjacent egress door.

• Match new door color to existing frame and surroundings

Building 16

Replacement

Scope of Work Attachment #7

Rear

Building 16 on right, Front View. Building 36 is on left.

An access drive is between 16 and 36. Connecting two buildings is referred to as a “breezeway”. New door will be located at the rear of breezeway, at the west side, facing the lake

Rear

Eastern overhead door at breezeway- at front of building. This front door photo is NOT the door to be replaced, BUT his might be an access point for work and materials -near by work location at rear.

Coordinate logistics and access with Owners Representative/ COR. The Breezeway is technically considered Bldg. 16

Front Door – Not in Scope

Rear view of the breezeway (west side).

New overhead door will replace existing shown.

Serves as a rear loading dock, approx. 3’-0” above grade

• Overhead Door to be replaced.

• Opening measures 10’-0” high x 10’0” wide.

• GC field verify all dimensions and existing conditions.

• Existing opening to remain, remove door and frame – replace with new. Protect gate and ladder during work.

Interior View of existing Overhead door – to be replaced.

GC coordinate power requirements with existing electrical service

Electric motor located at upper left of wall near door – to be removed and replaced with similar.

Existing Door Mfr:

Overhead Door Co

Of Southeastern MA

145 Tosca Drive

Stoughton, MA 02072

781-828-4033

Attn: Thomas Cafaro

Roll hood at Interior Coordinate with existing ceiling height

Provide controls similar to existing:

• Open

• Close

• Stop

• Mount new control at 36” above finish floor

Provide new sensing device/ electric eye, similar to existing

Existing Motor;

Vanguard Power Door Products Inc

Mamaroneck, NY UL Listed

Pedestrian Door Operator for commercial and industrial use

Model H

½ HP

115 Volts 1 Phase 60 Hz

Building 93

Replacement

Scope of Work Attachment #12

Front of Bldg. 93. South elevation.

Replace 2 doors Left (west) and Right (east)

View from interior of 93

Existing door base damaged from exterior moisture and road salt

DPW

Material Storage

Location of Bldg. 93

Replace 2 doors at south elevation East Door jamb and head - from interior, with pull chain and roll head above

Bldg. 93 Environmental Interior

• Metal siding building

• Secure, GC coordinate access with building owner rep

• Pull Chain, roll top head

• High Ceiling

Existing East Door

• Currently active

Existing West Door

• Currently active

• Blocked by stare materials. Owner will move materials prior to construction

East Door Size

Inside Dims:

10’-7” Wide

10’-1” High

Outside Opening size

9’-11” wide

10’-0” high

East Door, sill view

• Trench and grate near door base

• West door similar

East Door, elevation view

• Salt damage at base

• Replace entire door. West door similar

GC field verify all dimensions and existing conditions.

Existing opening to remain, remove door and frame – replace with new.

Protect metal siding

Existing doors

• Manually operated

• Pull Chain

• New doors will be motor operated

• Tie into existing electrical service

• GC Coordinate

Existing West Door

• Metal Siding Building

• Existing Door deteriorated at base form road salt

Building 5

Replacement -Welding Shop

Scope of Work Attachment #10

Front of Bldg. 5

Replace Door at Southwest Side of Bldg. 5

Location of Welding Shop Door at Bldg. 5 – South west side

Overhead Door serves as an egress path, includes Man Door with Panic Hardware

Current door uses an electric Motor to operate. Replace with similar new motor. GC coordinate with existing electrical service

GC field verify all dimensions and existing conditions. Exterior siding – precast concrete panels

Existing opening to remain, remove door and frame

– replace with new.

Roll Door at Interior

ODH Door Size at Interior:

Width: 10’-7” gross Height: 12’-0” to underside overhead roll case

Integral Man door Size:

Width: 3’-0” Height: 7’-0”

Exterior Opening Dimensions Width: 9’-11” clear Height 11’-7” clear

Man Door

Man Door sill/ threshold

Man door integrated into roll up door– match existing. Provide Exit Device at Interior, pull latch at Exterior and electromagnetic latch to secure.

Existing OH Door Header at Exterior-right side

Existing OH Door Jamb and Sill at Exterior-right side

Existing OH Door Jamb and Sill at Exterior – left side

Existing OH Door Header at Exterior-left side

Door frame is a steel substructure attached to exterior wall. New door frame similar., GC coordinate structural requirements.

Painted steel channel at door jamb forms outside opening – to remain, paint

Door frame sets face of door approx. 3” inboard from interior face of exterior wall, painted, black. New, similar

GC coordinate power requirements with existing electrical service

Building 44 Man Doors (2) Replacement -Futures

Scope of Work Attachment #G7

44-NE

North façade of building in East wing.

Metal Entry door with large centered vision panel. Two large side lites with tempered glazing. Metal frame, painted.

44-NW

North façade of building in West wing. Simple metal door in metal wall with large centered vision panel

Facing south Facing west

44-NW

Building 44 has two-man doors in scope. Both located on north sides of building - but in separate wings. Bldg. 44 is a metal building. Doors are framed into exterior metal walls. Doors as entry points to office space at grade near driveway. Salt from the snowplows has degrades the doors and frames at the base.

44-NE

44-NW

North façade of building in West wing.

Simple metal door in metal wall with large centered vision panel

44-NE

North façade of building in East wing. Metal Entry door with large centered vision panel. Two large side lites with tempered glazing. Metal frame, painted.

NOT

Overhead Doors

Entry Door

Width: 3’-0” Height: 6’-10 1/2” 2” metal frame at head and jamb. Aluminum threshold.

Install new Metal door with centered vision panel and hardware. Match existing.

Include closer. Coordinate keying systems with Post Locksmith via COR

44 W Interior – Sill, note rust at frame

44-NW

North façade of building in West wing.

Simple metal door in metal wall with large centered vision panel

44 W Interior - Head

Aluminum Threshold. Flush at grade

North façade of building in West wing.

Simple metal door in metal wall with large centered vision panel

Head at Exterior, metal siding with drip edge, closer, door locate under entry roof

Auto opener, Not operating. Restore function in new install

44-NW

North façade of building in West wing.

Simple metal door in metal wall with large

Repair Rust at exterior wall

North façade of building in West wing.

Simple metal door in

North façade of building in West wing.

Simple metal door in

44-NE

North façade of building in East wing. Metal Entry door with large centered vision panel. Two large side lites with tempered glazing. Metal frame, painted.

Entry Door/ Steel framed storefront assembly, tempered glazing

2” metal frame, painted, at head and jamb. Aluminum threshold.

Width: 3’-0” Height: 6’-11 1/2”

Install new Metal door with centered vision panel and hardware. Match existing.

Include closer. Coordinate keying systems with Post Locksmith via COR

East wing. Metal Entry door with large centered vision panel. Two large side lites with tempered glazing. Metal frame, painted.

44 E Interior 44 E Exterior

New paint colors to match existing.

Interior and exterior

East wing. Metal Entry door with large centered vision panel. Two large side lites with tempered glazing. Metal frame, painted.

Attach F - Map Facility
Sheets and Views
NSSC Basic Colored Map 2018-NSSC Map - Grid (For Public)
Attach G1- Bldg 16 - North OHD Photoset April 10 2023
Building 16�North End Wing�Overhead Door Replacement�
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Attach G2- Bldg 77 OHD Photoset July 5 2022
Building 77 Overhead Door Replacement� 2 Doors�North & South�Similar
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Attach G3- Bldg 86 Navy OHD Photoset July 8 2022
Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Attach G4- Bldg 16 OHD Breeze Photoset May 26 2022B
Building 16 Overhead Door Replacement
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Attach G5- Bldg 93DPW Environ OHD Photoset July 8 2022
Building 93 Overhead Door Replacement�
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Attach G6- Bldg 5 Welding OHD Photoset June 21 2022
Building 5 Overhead Door Replacement�-Welding �Shop
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Attach G7- Bldg 44 Futures Photoset May 18 2023
Building 44 Man Doors (2)�Replacement�-Futures
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10

File details come from the government source that posted it. Updated .