MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE‐DIX‐LAKEHURST (JB MDL)
PERFORMANCE PERIOD BASE YEAR
The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and structures at JB MDL , NJ in accordance with Statement of Work for period of performance: 16 Nov 20 through 15 Nov 21.
# desc QTY UNIT COST TOTAL COST QTY UNIT COST OTAL COST
0002 WOOD DOORS ‐ INTERIOR
0002AA Replace and paint wood interior, flush solid door 3'‐0" X 6'‐8" thru 7'‐3" 10 EA 10 EA
0003 WOOD DOOR FRAMES/MOLDINGS
0003AA Replace / paint single wood door frame, including casing and stops as applicable (maximum size 4'‐0" X 8'‐0") 5 EA 5 EA 0003AB Replace / paint double wood door frame, including casing and stops as applicable (maximum size 8' ‐ 0" X 8' ‐ 0") 5 EA 5 EA 0003AC Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'‐0" x 8'‐0" 5 EA 5 EA 0003AD Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'‐0" x 8'‐0" 5 EA 5 EA 0003AE Replace and paint wood door stops complete set for single wood door maximum size 4'‐0"x 8'‐0" 5 EA 5 EA 0003AF Replace and paint wood door stops complete set for double wood door maximum size 8'‐0"x 8'‐0" 5 EA 5 EA
0004 METAL DOORS ‐ INTERIOR
0004AA Replace and paint metal interior door 3'‐0" width x up to 8'‐0" height 3 EA 3 EA
0004AB ADD ‐ B Label fire (90 min) rated door to metal door 3 EA 3 EA
0005 METAL DOORS ‐ EXTERIOR
0005AA Replace and paint metal exterior door 3'‐0" x up to 8'‐0" height 25 EA 25 EA 0005AB ADD ‐ B Label fire (90 min) rated door to metal door 15 EA 15 EA
0006 METAL DOOR FRAMES
0006AA Replace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'‐0" x 8'‐0" 2 EA 2 EA
0006AB Replace/paint double metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'‐0" x 8'‐0" 2 EA 2 EA
0007 DOOR ACCESSORIES
0007AA Aluminum Threashold Up to 36" length 2 EA 2 EA 0007AB Aluminum Threashold>36" up to 72" length 2 EA 2 EA 0007AC Replace exit or panic device stainless steel or bronze as specified ‐ Single Door complete rim exit bolt includes pull with thumb piece and cylinder lock 10 EA 10 EA 0007AD Replace surface mounted door closer as required with regular arm Interior and exterior wood or metal doors 10 EA 10 EA 0007AE Replace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete including screws steel pins 20 EA 20 EA 0007AF Remove existing hinges and install anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface) 20 EA 20 EA 0007AG replace cylindrical type latch set(passage) 20 EA 20 EA 0007AH replace cylindrical type latch set Knob SFIC 20 EA 20 EA 0007AI replace cylindrical type latch set Lever SFIC 20 EA 20 EA 0007AJ install push plate/pull handle on free swing door wood or metal 15 EA 15 EA 0008 REPLACE and PAINT GYPSUM WALL BOARD
0008AA Replace and Paint Gypsum wall board including finish taping, three coat of spackling, one coat of primer paint and two finish coats of paint ‐ minimum 16 SF 20,000 SF 20,000 SF
0009 INTERIOR WOOD WALL BASE
0009AA Wood Base Replace & paint 1" x 6" wood base minimum 5 LF 500 LF 500 LF 0009AB Shoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF 500 LF 500 LF
0010 PLYWOOD INTERIOR
0010AA Replace Plywood 1/4" 500 SF 500 SF
0011 FLOOR PREPARATION
0011AA Patch concrete floor surfaces with Portland cement max size 6" thick x 2 SF 1 EA 1 EA 0011AB Replace rubber stair tread 13" wide x 48" 5/16 (Length typical) 100 EA 100 EA 0011AC Replace Aluminum Safety Tread 100 EA 100 EA 0012 RUBBER or VINYL WALL BASE
0012AA Replace 4" high (all colors) 40,000 LF 40,000 LF 0012AB Replace 6" high (all colors) 10,000 LF 10,000 LF
Base Year Option Year 1
0013 VCT FLOORING (VINYL COMPOSITION TILE)
0013AA Remove / Replace existing VCT with New VCT size 12" x 12" x 1/8 minimum 100 SF 100,000 SF 100,000 SF 0013AB Replace aluminum edge strips 60 LF 60 LF 0013AC Replace vinyl plastic edge strips 60 LF 60 LF
0014 SHEET FLOORING
0014AA
Flooring / Replace Sheet Linoleum ‐ installation shall be done in a fashion that will minimize floor seams all seams must conform to manufacturer's specification in compliance with section 09950 of the specification
3,750 SF 3,750 SF
0014AB Linoleum Heat Weld Seaming 1,000 LF 1,000 LF 0014AC Integral Cove Base 1,000 LF 1,000 LF
0015 CARPET
0015AA Replace Carpet with Broadloom Carpet 2,000 SY 2,000 SY 0015AB Replace Carpet with Carpet Tiles (24" x 24") 20,000 SY 20,000 SY
0016 SUSPENDED CEILINGS ‐ TILES
0016AA Replace ceiling grid for acoustic lay‐in panel suspension system 10,000 SF 10,000 SF 0016Ab Replace mineral fiber acoustical lay‐in‐panels in existing suspension systems maximum 3/4" thick patterns vary 10,000 SF 10,000 SF
0017 CEILING ACCESSORIES
0017AA Replace Suspended Ceiling HVAC diffusers, 2' x 2' 15 EA 15 EA
0018 INTERIOR MISCELLANEOUS ITEMS
0018AA Plate / Wall, Plastic ‐ Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification 50 EA 50 EA
0019 ELECTRICAL RECEPTACLES/SWITCHES/BOXES
0019AA Recessed Grid 2' x 2' Troffer, Static, Lensed, full flush steel door. Number lamps ‐2 lamp type ‐ Replace with LED equivalent 40 EA 40 EA 0019AB Recessed Grid 2' x 4' Troffer, Static, Lensed, Number lamps ‐4 lamp type ‐ Replace with LED equivalent 30 EA 30 EA
0020 EMERGENCY LIGHTS/EXIT SIGNS
0020AA Replace Emergency light 6 volt battery pack unit 2/two LED floodlights 25 EA 25 EA 0020AB Replace Emergency light 2' x 2' w/ battery back up ‐ LED 25 EA 25 EA 0020AC Replace Exit Sign with LED Exit Sign ‐ red color lettering 20 EA 20 EA
0021 SURFACE PREPARATION
0021AA Surface preparation for extreme scraping, patching and cleaning of grease from surface to be painted 10,000 SF 10,000 SF
0021AB
Pressure Washing ‐ pressure wash of exterior building surfaces to remove dirt, oil, residues and other coatings using a pump capable of minimum 3000 PSI. Bleach solution shall be sprayed on from top to bottom allowed to yield and rinse to remove all bleach residue
100,000 SF 100,000 SF
0021AC Sandblast of Masonry or Metal surfaces prior to painting 5,000 SF 5,000 SF 0021AD Repair Cracks in masonry not to exceed 2" wide 500 LF 500 LF 0021AE Repair Holes in masonry surfaces not to exceed 2" diameter 20 EA 20 EA 0021AF Repair Cracks in interior surfaces prior to painting 100 LF 100 LF 0021AG Repair Holes in interior surfaces not to exceed 2" diameter 100 EA 100 EA
0022 INTERIOR PAINTING
0022AA Furnish all labor and materials necessary to prime and paint interior surfaces ‐ 2 finish coats 500,000 SF 500,000 SF 0022AB Paint 1 coat previously painted interior surface in accordance with specification 500,000 SF 500,000 SF 0022AC Each additional interior coat of paint in accordance with specification 100,000 SF 100,000 SF 0023 REFINISHING of STAINED, POLYURETHANED INTERIOR ITEMS 0023A Refinish with 1 coat in accordance with specification 200 SF 200 SF 0023AB Each additional coat in accordance with specification 200 SF 200 SF
0024 PAINT EXTERIOR SURFACES
0024AA Paint 1 coat previously painted exterior surface in accordance with specifications 200,000 SF 200,000 SF 0024AB Each additional exterior coat of paint in accordance with specifications 200,000 SF 200,000 SF
0025 MASONRY ‐ INTERIOR
0025AA Repair interior masonry surfaces (cracks, spalls, holes) up to 1/4" wide, with a maximum of 4" in depth 100 LF 100 LF
0026 MASONRY ‐ EXTERIOR
0026AA Replace/apply caulking between similar or dissimilar interior or exterior construction material to include backup material as required 250 LF 250 LF 0027 OVERHEAD ROLL UP DOORS ‐ Doors up to Nominal Height of 16 feet
0027AA Replace steel overhead roll‐up doors up to nominal width of 16' ‐ Uninsulated 1,000 SF 1,000 SF 0027AB ADD for insulated steel door 1,000 SF 1,000 SF 0027AC Replace aluminum overhead roll‐up doors up to nominal width of 16' ‐ Uninsulated 500 SF 500 SF 0027AD ADD for insulated aluminum door 500 SF 500 SF 0028 SECTIONAL DOORS ‐ Up to Nominal height of 16'
0028AA Replace steel overhead sectional doors up to nominal width of 16' ‐ Unisulated 500 SF 500 SF 0028AB ADD for insulated sectional door 500 SF 500 SF
0029 OVERHEAD DOOR ACCESSORIES
0029AA Replace door springs ‐ Sectional Doors 6 EA 6 EA 0029AB Replace door springs ‐ Roll Up Doors 6 EA 6 EA 0029AC Replace cables 6 EA 6 EA 0029AD Replace electric door operators {chain or belt) ‐ 1/2HP 6 EA 6 EA 0029AE Replace electric door operators {chain or belt) ‐ 3/4 HP 6 EA 6 EA 0029AF Replace electric door operators {chain or belt) ‐ 1 HP 6 EA 6 EA 0029AG Replace electric door operator safety bottom edge 6 EA 6 EA 0029AH Replace pneumatic door operator safety bottom edge 6 EA 6 EA 0029AI Repair/replace tracks 6 EA 6 EA 0029AJ Replace hinges and rollers. 6 EA 6 EA 0029AK Replace neoprene internal hood baffles 6 LF 6 LF 0029AL Replace neoprene astragal 6 EA 6 EA 0029AM Replace vision panels 6 EA 6 EA 0029AN Replace weather stripping 600 LF 600 LF 0029AO Replace motor on operator 6 EA 6 EA 0029AP Adjust Limits on Overhead Door 6 EA 6 EA 0029AQ Replace 3 button, push button control station and all required metal raceway components 12 EA 12 EA
0029AR 6 EA 6 EA
0030 Labor / Skilled ‐ perform minor repairs as directed by QAR to include carpentry, electrical, plumbing and metal trades
0030AA Perform miscellaneous minor carpentry work 500 HR 500 HR 0030AB Perform miscellaneous minor electrical work 200 HR 200 HR 0030AC Perform miscellaneous minor plumbing work 100 HR 100 HR 0030AD Perform miscellaneous labor work 400 HR 400 HR 0030AE Perform miscellaneous sheet metal work 100 HR 100 HR 0030AF Perform miscellaneous welding work 50 HR 50 HR
0030AG
Move Furniture and Partition ‐ Disassemble, Move, and Re‐assemble to facilitate replacement of flooring. Not to be used for lifting in place, movement of chairs, or furniture items not requiring assembly.
1,000 SF 1,000 SF
0031 VINYL WALL COVERINGS
0031AA Remove wall covering , adhesives and apply skim coat and 1 coat of prime 10,000 SF 10,000 SF
0032 EXTERIOR WINDOW REPLACEMENT
0032AA Remove/Replace impact resistant window in accordance with UFC 4‐010‐01 450 SF 450 SF 0033 ASBESTOS ABATEMENT ‐ Complete Removal, all tests , monitoring, setups, notifications, material, labor and disposal of asbestos floor tile and insulation
0033AA Asbestos floor tile and mastic Removal 5,000 SF 5,000 SF 0034 BONDING FOR PROJECTS EXCEEDING $250k .0317%
Grand Total ‐$ Grand Total ‐$