BID SCDL

MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT JOINT BASE MCGUIRE-DIX-LAKEHURST (JB MDL)
PERFORMANCE PERIOD BASE YEAR
CLIN #Description
Base Year 15 Jul 22 - 14 Jul 23Option Year 1 15 Jul 23 - 14 Jul 24
0001The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and structures at JB MDL , NJ in accordance with Statement of Work for period of performance: 15 July 2022 through 14 July 2024.QTYUNITCOSTTOTAL COSTQTYUNITCOSTTOTAL COST
0002WOOD DOORS - INTERIOR
0002AAReplace and paint wood interior, flush solid door 3'-0" X 6'-8" thru 7'-3"10EA$ - 010EA$ - 0
0003WOOD DOOR FRAMES/MOLDINGS
0003AAReplace / paint single wood door frame, including casing and stops as applicable (maximum size 4'-0" X 8'-0")5EA$ - 05EA$ - 0
0003ABReplace / paint double wood door frame, including casing and stops as applicable (maximum size 8' - 0" X 8' - 0")5EA$ - 05EA$ - 0
0003ACReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'-0" x 8'-0"5EA$ - 05EA$ - 0
0003ADReplace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'-0" x 8'-0"5EA$ - 05EA$ - 0
0003AEReplace and paint wood door stops complete set for single wood door maximum size 4'-0"x 8'-0"5EA$ - 05EA$ - 0
0003AFReplace and paint wood door stops complete set for double wood door maximum size 8'-0"x 8'-0"5EA$ - 05EA$ - 0
0004METAL DOORS - INTERIOR
0004AAReplace and paint metal interior door 3'-0" width x up to 8'-0" height3EA$ - 03EA$ - 0
0004ABADD - B Label fire (90 min) rated door to metal door3EA$ - 03EA$ - 0
0005METAL DOORS - EXTERIOR
0005AAReplace and paint metal exterior door 3'-0" x up to 8'-0" height25EA$ - 025EA$ - 0
0005ABADD - B Label fire (90 min) rated door to metal door15EA$ - 015EA$ - 0
0006METAL DOOR FRAMES
0006AAReplace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'-0" x 8'-0"2EA$ - 02EA$ - 0
0006ABReplace/paint double metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'-0" x 8'-0"2EA$ - 02EA$ - 0
0007DOOR ACCESSORIES
0007AAAluminum Threashold Up to 36" length2EA$ - 02EA$ - 0
0007ABAluminum Threashold>36" up to 72" length2EA$ - 02EA$ - 0
0007ACReplace exit or panic device stainless steel or bronze as specified - Single Door complete rim exit bolt includes pull with thumb piece and cylinder lock10EA$ - 010EA$ - 0
0007ADReplace surface mounted door closer as required with regular arm Interior and exterior wood or metal doors10EA$ - 010EA$ - 0
0007AEReplace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete including screws steel pins20EA$ - 020EA$ - 0
0007AFRemove existing hinges and install anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface)20EA$ - 020EA$ - 0
0007AGreplace cylindrical type latch set(passage)20EA$ - 020EA$ - 0
0007AHreplace cylindrical type latch set Knob SFIC20EA$ - 020EA$ - 0
0007AIreplace cylindrical type latch set Lever SFIC20EA$ - 020EA$ - 0
0007AJinstall push plate/pull handle on free swing door wood or metal15EA$ - 015EA$ - 0
0008REPLACE and PAINT GYPSUM WALL BOARD
0008AAReplace and Paint Gypsum wall board including finish taping, three coat of spackling, one coat of primer paint and two finish coats of paint - minimum 16 SF20,000SF$ - 020,000SF$ - 0
0009INTERIOR WOOD WALL BASE
0009AAWood Base Replace & paint 1" x 6" wood base minimum 5 LF500LF$ - 0500LF$ - 0
0009ABShoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF500LF$ - 0500LF$ - 0
0010PLYWOOD INTERIOR
0010AAReplace Plywood 1/4"500SF$ - 0500SF$ - 0
0011FLOOR PREPARATION
0011AAPatch concrete floor surfaces with Portland cement max size 6" thick x 2 SF1EA$ - 01EA$ - 0
0011ABReplace rubber stair tread 13" wide x 48" 5/16 (Length typical)100EA$ - 0100EA$ - 0
0011ACReplace Aluminum Safety Tread100EA$ - 0100EA$ - 0
0012RUBBER or VINYL WALL BASE
0012AAReplace 4" high (all colors)40,000LF$ - 040,000LF$ - 0
0012ABReplace 6" high (all colors)10,000LF$ - 010,000LF$ - 0
0013VCT FLOORING (VINYL COMPOSITION TILE)
0013AARemove / Replace existing VCT with New VCT size 12" x 12" x 1/8 minimum 100 SF100,000SF$ - 0100,000SF$ - 0
0013ABReplace aluminum edge strips60LF$ - 060LF$ - 0
0013ACReplace vinyl plastic edge strips60LF$ - 060LF$ - 0
0014SHEET FLOORING
0014AAFlooring / Replace Sheet Linoleum - installation shall be done in a fashion that will minimize floor seams all seams must conform to manufacturer's specification in compliance with section 09950 of the specification3,750SF$ - 03,750SF$ - 0
0014ABLinoleum Heat Weld Seaming1,000LF$ - 01,000LF$ - 0
0014ACIntegral Cove Base1,000LF$ - 01,000LF$ - 0
0015CARPET
0015AAReplace Carpet with Broadloom Carpet2,000SY$ - 02,000SY$ - 0
0015ABReplace Carpet with Carpet Tiles (24" x 24")20,000SY$ - 020,000SY$ - 0
0016SUSPENDED CEILINGS - TILES

CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA: CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA:

Hanging ceiling tiles are not addressed in the PWS.

0016AAReplace ceiling grid for acoustic lay-in panel suspension system10,000SF$ - 010,000SF$ - 0
0016AbReplace mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4" thick patterns vary10,000SF$ - 010,000SF$ - 0
0017CEILING ACCESSORIES
0017AAReplace Suspended Ceiling HVAC diffusers, 2' x 2'15EA$ - 015EA$ - 0
0018INTERIOR MISCELLANEOUS ITEMS
0018AAPlate / Wall, Plastic - Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification50EA$ - 050EA$ - 0
0019ELECTRICAL RECEPTACLES/SWITCHES/BOXES
0019AARecessed Grid 2' x 2' Troffer, Static, Lensed, full flush steel door. Number lamps -2 lamp type - Replace with LED equivalent40EA$ - 040EA$ - 0
0019ABRecessed Grid 2' x 4' Troffer, Static, Lensed, Number lamps -4 lamp type - Replace with LED equivalent30EA$ - 030EA$ - 0
0020EMERGENCY LIGHTS/EXIT SIGNS

CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA: CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA:

Not in the SOW.

CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA: CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA:

Hanging ceiling tiles are not addressed in the PWS.0020AAReplace Emergency light 6 volt battery pack unit 2/two LED floodlights25EA$ - 025EA$ - 0
0020ABReplace Emergency light 2' x 2' w/ battery back up - LED25EA$ - 025EA$ - 0
0020ACReplace Exit Sign with LED Exit Sign - red color lettering20EA$ - 020EA$ - 0
0021SURFACE PREPARATION
0021AASurface preparation for extreme scraping, patching and cleaning of grease from surface to be painted10,000SF$ - 010,000SF$ - 0
0021ABPressure Washing - pressure wash of exterior building surfaces to remove dirt, oil, residues and other coatings using a pump capable of minimum 3000 PSI. Bleach solution shall be sprayed on from top to bottom allowed to yield and rinse to remove all bleach residue100,000SF$ - 0100,000SF$ - 0
0021ACSandblast of Masonry or Metal surfaces prior to painting5,000SF$ - 05,000SF$ - 0
0021ADRepair Cracks in masonry not to exceed 2" wide500LF$ - 0500LF$ - 0
0021AERepair Holes in masonry surfaces not to exceed 2" diameter20EA$ - 020EA$ - 0
0021AFRepair Cracks in interior surfaces prior to painting100LF$ - 0100LF$ - 0
0021AGRepair Holes in interior surfaces not to exceed 2" diameter100EA$ - 0100EA$ - 0
0022INTERIOR PAINTING
0022AAFurnish all labor and materials necessary to prime and paint interior surfaces - 2 finish coats500,000SF$ - 0500,000SF$ - 0
0022ABPaint 1 coat previously painted interior surface in accordance with specification500,000SF$ - 0500,000SF$ - 0
0022ACEach additional interior coat of paint in accordance with specification100,000SF$ - 0100,000SF$ - 0
0023REFINISHING of STAINED, POLYURETHANED INTERIOR ITEMS
0023ARefinish with 1 coat in accordance with specification200SF$ - 0200SF$ - 0
0023ABEach additional coat in accordance with specification200SF$ - 0200SF$ - 0
0024PAINT EXTERIOR SURFACES
0024AAPaint 1 coat previously painted exterior surface in accordance with specifications200,000SF$ - 0200,000SF$ - 0
0024ABEach additional exterior coat of paint in accordance with specifications200,000SF$ - 0200,000SF$ - 0
0025MASONRY - INTERIOR
0025AARepair interior masonry surfaces (cracks, spalls, holes) up to 1/4" wide, with a maximum of 4" in depth

CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA: CAMACHO, JAKE A TSgt USAF AMC 87 CONS/PKA:

Not in the SOW.100LF$ - 0100LF$ - 0
0026MASONRY - EXTERIOR
0026AAReplace/apply caulking between similar or dissimilar interior or exterior construction material to include backup material as required250LF$ - 0250LF$ - 0
0027OVERHEAD ROLL UP DOORS - Doors up to Nominal Height of 16 feet
0027AAReplace steel overhead roll-up doors up to nominal width of 16' - Uninsulated1,000SF$ - 01,000SF$ - 0
0027ABADD for insulated steel door1,000SF$ - 01,000SF$ - 0
0027ACReplace aluminum overhead roll-up doors up to nominal width of 16' - Uninsulated500SF$ - 0500SF$ - 0
0027ADADD for insulated aluminum door500SF$ - 0500SF$ - 0
0028SECTIONAL DOORS - Up to Nominal height of 16'
0028AAReplace steel overhead sectional doors up to nominal width of 16' - Unisulated500SF$ - 0500SF$ - 0
0028ABADD for insulated sectional door500SF$ - 0500SF$ - 0
0029OVERHEAD DOOR ACCESSORIES
0029AAReplace door springs - Sectional Doors6EA$ - 06EA$ - 0
0029ABReplace door springs - Roll Up Doors6EA$ - 06EA$ - 0
0029ACReplace cables6EA$ - 06EA$ - 0
0029ADReplace electric door operators {chain or belt) - 1/2HP6EA$ - 06EA$ - 0
0029AEReplace electric door operators {chain or belt) - 3/4 HP6EA$ - 06EA$ - 0
0029AFReplace electric door operators {chain or belt) - 1 HP6EA$ - 06EA$ - 0
0029AGReplace electric door operator safety bottom edge6EA$ - 06EA$ - 0
0029AHReplace pneumatic door operator safety bottom edge6EA$ - 06EA$ - 0
0029AIRepair/replace tracks6EA$ - 06EA$ - 0
0029AJReplace hinges and rollers.6EA$ - 06EA$ - 0
0029AKReplace neoprene internal hood baffles6LF$ - 06LF$ - 0
0029ALReplace neoprene astragal6EA$ - 06EA$ - 0
0029AMReplace vision panels6EA$ - 06EA$ - 0
0029ANReplace weather stripping600LF$ - 0600LF$ - 0
0029AOReplace motor on operator6EA$ - 06EA$ - 0
0029APAdjust Limits on Overhead Door6EA$ - 06EA$ - 0
0029AQReplace 3 button, push button control station and all required metal raceway components12EA$ - 012EA$ - 0
0030Labor / Skilled - perform minor repairs as directed by QAR to include carpentry, electrical, plumbing and metal trades
0030AAPerform miscellaneous minor carpentry work500HR$ - 0500HR$ - 0
0030ABPerform miscellaneous minor electrical work200HR$ - 0200HR$ - 0
0030ACPerform miscellaneous minor plumbing work100HR$ - 0100HR$ - 0
0030ADPerform miscellaneous labor work400HR$ - 0400HR$ - 0
0030AEPerform miscellaneous sheet metal work100HR$ - 0100HR$ - 0
0030AFPerform miscellaneous welding work50HR$ - 050HR$ - 0
0030AGMove Furniture and Partition - Disassemble, Move, and Re-assemble to facilitate replacement of flooring. Not to be used for lifting in place, movement of chairs, or furniture items not requiring assembly.1,000SF$ - 01,000SF$ - 0
0031VINYL WALL COVERINGS
0031AARemove wall covering , adhesives and apply skim coat and 1 coat of prime10,000SF$ - 010,000SF$ - 0
0032EXTERIOR WINDOW REPLACEMENT
0032AARemove/Replace impact resistant window in accordance with UFC 4-010-01450SF$ - 0450SF$ - 0
0033ASBESTOS ABATEMENT - Complete Removal, all tests , monitoring, setups, notifications, material, labor and disposal of asbestos floor tile and insulation
0033AAAsbestos floor tile and mastic Removal5,000SF$ - 05,000SF$ - 0
0034BONDING FOR PROJECTS EXCEEDING $250k .0317%
Grand Total$ - 0Grand Total$ - 0