This sources sought notice requests capability statements from vendors able to provide custom-made airfield lighting signs and replacement fixtures. Interested offerors should provide details of their experience manufacturing commercial, industrial, and institutional electric lighting fixtures. Capability statements are due no later than February 14, 2024 and should include the vendor's business classification, past government contract experience, and distinguishing capabilities. The Air Force will use responses to inform acquisition planning for potential future procurement of signs that match existing airfield assets and ensure pilot and aircraft safety.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sign Specs Temperature: -40 °F to +131 °F (-40 °C to +55 °C)

Humidity: 0 to 100%

Wind: Mode 2 signs required (signs withstand wind velocities up to 200 mph)

Unique LED Light Bar design maximizes energy efficiency

• Available Battery Tester provides for quick and easy testing of individual LED Light Bars

• Electrical design uses a minimal number of components which maximizes sign MTBF and greatly simplifies troubleshooting efforts.

• Virtually eliminates runway and taxiway shutdowns due to long-lasting LED light source

• Custom made for Direct replacement of existing sign

• Creates a highly uniform distribution of light, eliminating hot spots and shadows

• Operates on flo resonant or thyristor CCRs that are designed in compliance with FAA or IEC requirements

• Operates on all steps of a 3-step or 5-step CCR and on a 5.5 A CCR.

• Rugged lightning protection that complies with ANSI/IEEE C62.41-1991 Location Category C2 given in FAA Eng. Brief 67.

Category C2 is defined as a 1.2/50μS – 8/20 μS combination wave, with a peak voltage of 10,000 Volts and a peak current of 5,000

Specs for rest of items

PAR 56 STEADY BURNING LIGHT ; CLEAR ; 6.6 AMP

SHORTING DEVICE ; WITH L823 CORD SET ; SLIP FITTER

FOR 2" EMT

COUPLING ; FRANGIBLE ; 2" ; BLACK ; THRD / SMOOTH

COMPLETE FIXTURE ; QUARTZ ; 200W LAMP

CLEAR /CLEAR ; 14" O.A.H. ; 2" SWIVEL

COMPLETE FIXTURE ; QUARTZ ; 200W LAMP

CLEAR / YELLOW ; 14" O.A.H. ; 2" SWIVEL

COMPLETE SIGN ; HIGH WIND ; LED ; SIZE 4 ; 1 MOD ;

DOUBLE FACE ; 2 PANELS ; POWER THRU LEG ; WITH

ON/OFF SWITCH ;

COMPLETE SIGN ; HIGH WIND ; LED ; SIZE 1 ; 1 MOD ;

SINGLE FACE ; 2 PANELS ; POWER THRU LEG ; WITH ON/OFF

SWITCH ; 1 TETHER PER LEG

EPOXY KIT ; 1 QT. OF BOTH PART 'A' AND PART 'B'

MG 20 TOWER MAST ; 20' FT ; FIBERGLASS ; JAQUITH

CROSS BAR ; ALSF 5 ; @ 40.5"

TEE BRACE CLAMP ASSEMBLY

TEE BRACE ( 2 REQUIRED PER CROSS BAR )

PAR LAMP SUPPORT ADAPTER

MG 20 FRANGIBLE ANCHOR BOLT

MG 20 ANCHOR BOLT SET FOR FUSE BOLT APPLICATION ;

JAQUITH

ANCHOR PLATE

FLASHER BRACKET WITH J-BOX

MG 20 MOUNTING STAND