S02 ATTACH VA 852-042 - JBNC SS Phase 1 Drawings - Part 8.pdf
PDF 20 MB Posted
- Attached to
- Jefferson Barracks National Cemetery, Sylvan Springs, Phase 1 Development Federal contract opportunity
- Solicitation number
- 36C10F25R0006
View the file
Other files for this federal contract opportunity
Show all 50
Jefferson Barracks National Cemetery, Sylvan Springs, Phase 1 Development has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UE x
U E x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx
Gx
PL PL PL PL PL PL PL PL PL PL PL PL
UE x
U E x
Gx Gx Gx Gx Gx Gx Gx Gx Gx Gx
Gx
PL PL PL PL PL PL PL PL PL PL PL PL
FFE: 477.81
-2 .5
-2 .5
-2 .5
-2 .5
-8.0%
-2.5%
-2.5%
-2 .0
-1 .4
% -1 .4
% -1 .4
-2.5%
-2 .0
-2.5%
-1 .8
-1 .8
-5.1%
-4.2%
-25.0%
-2.5%
-2.5%
-25.0%
-1 .8
-3.0%
-3.0%
-3.0%
-2.0%
-1.0%-1.0%
-2 5.
0%
-25.0%
-2 5.
0%
-1 .8
LOD LOD
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
48.00'
34.00'
44.69'
39.65'
124.91'
161.12'
121.38'
66.02'
45.32'
29.15'
28.79'
.5
7'
18'
12.00'
11' 5'
5'
PROPOSED IRRIGATION CONTROL AND
EQUIPMENT VAULT, IRRIGATION EQUIPMENT
CONNECTION TO 8" WATER PIPE EXTENSION.
SEE IRRIGATION PLANS FOR MORE
INFORMATION.
8" WATER
LINE VALVE
6" WATER
LINE VALVE
-2 .1
-2 .1
-2 .0
-2 .1
-2 .0
-2 .0
-3.0%
-7.5%
KEYNOTES: NOT ALL KEYNOTES USED ON SHEET
1. CONSTRUCT ASPHALT ROADWAY: 1/CS501.
2. CONSTRUCT MOUNTABLE CURB AND GUTTER: 6/CS501.
3. CONSTRUCT CONCRETE SIDEWALK. 3/CS501.
4. CONSTRUCT 5 FT, VINYL COATED CHAIN LINK FENCE: SEE 1/LC532.
5. MOW STRIP: SEE 5/LC532.
6. CONSTRUCT NEW ASPHALT LANE (ROAD WIDENING): SEE 1/CS501.
7. MILL AND REPLACE SHERIDAN ROAD: SEE 1 AND 2/CS501, CP209.
8. INSTALL FIRE HYDRANT: SEE 5/CS504.
9. INSTALL CONCRETE TRANSFORMER PAD/VAULT: SEE ELEC. PLANS
10. CONSTRUCT FLOWER WATERING STATION: 1/LS503.
11. CONSTRUCT GRAVE SITE LOCATOR: SEE GC404.
12. CONSTRUCT CONCRETE MAINTENANCE YARD. 12/CS501.
13. CONSTRUCT MAINTENANCE BUILDING: SEE GC405.
14. CONSTRUCT MATERIAL STORAGE BUILDING: SEE CG405.
15. CONSTRUCT COLUMBARIUM: SEE GC 400.
16. CONSTRUCT COMMITTAL SHELTER: SEE GC403.
17. CONSTRUCT DECORATIVE WALL: SEE GC403.
18. CONSTRUCT RETAINING WALL: SEE SHEETS CI001-CI505.
19. INSTALL ADA CURB RAMP (TYP.): SEE 12/LC524.
20. CONSTRUCT SWING GATE/FENCE WITH COLUMNS: SEE 9/LC531.
21. INSTALL VINYL COATED CHAIN LINK SWING GATE: SEE 2/LC532.
22. INSTALL VINYL COATED CHAIN LINK FENCE ROLL GATE: SEE 4/LC532.
23. CONSTRUCT 8 FT SECURITY CHAIN LINK FENCE, BLACK, VINYL
COATED: SEE 3/LC532.
24. GRAVEL ACCESSES ROAD: SEE 5/CS501.
25. INSTALL BOLLARDS BETWEEN GARAGE DOORS: SEE20/AB-505.
26. INSTALL MECHANICAL PAD: SEE 13/CS501.
27. CONSTRUCT FLUSH CURB: SEE 7/CS501.
28. CONSTRUCT VALLEY GUTTER: SEE 8/CS501.
29. CONSTRUCT VERTICAL CURB AND GUTTER: SEE 9/CS501
30. CONSTRUCT CONCRETE CURB TRANSITION: SEE 10,11/CS501
31. INSTALL CONCRETE ADA TACTILE DOME PAVERS (TYP.): SEE 4/CS508
XX
GENERAL NOTES:
1. GRADE THE SITE TO DRAIN FREELY.
2. ADJUST RIMS OF EXISTING MANHOLES TO PROPOSED GRADES.
NOTIFY ST. LOUIS MSD PRIOR TO AND AT COMPLETION OF
MODIFICATION TO EXISTING ST. LOUIS MSD STRUCTURES.
MODIFICATIONS, ABANDONMENT AND REMOVAL OF EXISTING
STRUCTURES TO BE PERFORMED PER ST. LOUIS MSD STANDARDS.
3. SUBGRADE FOR CRYPT FIELD TO MIRROR FINISHED GRADES UNLESS
OTHERWISE NOTED.
4. THERE ARE NO STORAGE AREAS OUTSIDE THE CONSTRUCTION SITE
FOR EXCESS EXCAVATED SOILS OR FOR EXCAVATED SOILS TO BE
REUSED AS BACKFILL. CONTRACTOR TO LOCATE SUITABLE PLACE ON
SITE IF NEEDED.
5. CONTRACTOR SHALL PROVIDE AN APPROPRIATE AREA OFF-SITE ON
WHICH TO DISPOSE OF ALL SOILS NOT TO BE REUSED AS BACKFILL
OR TOPSOIL.
SITE LEGEND
GRAVEL
CONCRETE PAVEMENT
ASPHALT PAVEMENT
MILL AND REPLACE
PROPERTY LINE
UTILITY EASMEANT
FIRE HYDRANT
SANITARY SEWER MANHOLE
STORMWATER STRUCTURE
STORMWATER MANHOLE
WATER METER
HYDRODYNAMIC SEPARATOR
SITE FEATURES
HANDICAP PARKING
FLOWERING WATERING
STATION
PERIMETER FENCE AND WALL
GRAVE SITE MARKER
SIGN
xxxxx
PL
15" HACKBERRY
15" HACKBERRY
451451
451451
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
CIVIL SITE PLAN
SHEET 11 OF 11
JTKHJM
Scale: 1"=20'1 SITE PLAN AT MAINTENANCE YARD AND LOCATOR KIOSK
Scale: 1"=20'2 SITE PLAN AT RETAINING WALL
N
GRAPHIC SCALE
1" = 20'
20'0 40'10'
CONDENSATE
DRAIN, DAYLIGHT
ADA ACCESSIBLE
FLUSH CURB
KEY MAP
CS107
CS108
CS104 CS106
CS101
CS111
CS103
MAINTENANCE BUILDING
FFE: 477.81
22.00'
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text W
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text B.H.
AutoCAD SHX Text E
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text E
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text B.H.
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text D.S.
AutoCAD SHX Text D.S.
AutoCAD SHX Text
PP
AutoCAD SHX Text
PP
AutoCAD SHX Text W
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text
FOM
AutoCAD SHX Text B.H.
AutoCAD SHX Text E
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
GM
AutoCAD SHX Text E
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text B.H.
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text
IRR
AutoCAD SHX Text D.S.
AutoCAD SHX Text D.S.
AutoCAD SHX Text
CS111
AutoCAD SHX Text
MILL THE 12"
OUTSIDE PERIMETER AT
2" DEPTH FOR A
MOISTURE BARRIER LIP
TACK COAT (SS-1H)
@ 0.05 GAL/SY
BETWEEN LIFTS
NOTES:
1. ASPHALT BINDER SHALL BE 70-16.
2. ENSURE THAT CONSTRUCTION METHODS AND MATERIALS ARE COMPLIANT WITH
THE STANDARDS OF ST. LOUIS COUNTY DEPARTMENT OF TRANSPORTATION.
Scale: NTS
ASPHALT PAVEMENT DETAIL (TYPICAL)1
2" TYPE "C" ASPHALT SURFACE COURSE
3" ASPHALT BINDER COURSE
10" AGGREGATE BASE
COURSE, MODOT TYPE 5
AGGREGATE, COMPACTED TO
MINIMUM 98% DRY DENSITY
12" COMPACTED (IN FILL) OR SCARIFIED AND
RE-COMPACTED (IN CUT) SUBGRADE. IF HIGH
PLASTICITY SOILS ENCOUNTERED UNDER
ROADWAY, REPLACE UPPER 12 INCHES WITH
ENGINEERED/LOW PLASTICITY SOIL, COMPACT.
Scale: NTS
ASPHALT ABUTMENT DETAIL (TYPICAL)2
SAWCUT EXISTING ASPHALT FULL DEPTH
TACK COAT
(SS-1H)
CONCRETE CURB
& GUTTER
REFER TO ASPHALT
PAVEMENT DETAIL
(3) #4 REBAR CONT.
4" AGGREGATE BASE COURSE
95% COMPACTION
FINISH GRADE
NOTES:
1. DETAIL ONLY USED FOR CURB AND GUTTER AT SHERIDAN ROAD.
2. MIN. 4000 PSI CONCRETE.
3. PROVIDE EXPANSION JOINTS @ 50'-0" O.C. NON-EXPANDING EXTRUDED EXP. JOINT MATERIAL.
4. PROVIDE TOOLED CONTROL JOINTS @ 10'-0" O.C.
5. TIE BACK TO EXISTING W/ LUBRICATED EPOXY COATED #4 DOWEL BAR.
6"
6"
32" (TYP.)
MATCH EXISTING
Scale: NTS
VERTICAL CURB AND GUTTER (TYPICAL)9
1/4" 3/8"
1/4" R
JOINT SEALANT
CONTROL JOINT EXPANSION JOINT
XXXXXXXXXXX
Scale: NTS
(LIGHT DUTY) CONCRETE WALK DETAIL (TYPICAL)3
5" 6"
2" M
IN
CIP CONCRETE
MEDIUM BROOM FINISH
SWEEP PERPENDICULAR TO
DIRECTION OF TRAFFIC
6x6-W1.4xW1.4 WWF, USE CHAIRS TO SUPPORT WWF
(TYPE 5) AGGREGATE BASE
4" COMPACTED SUBGRADE 95%
Scale: NTS
CONCRETE JOINTING DETAIL (TYPICAL)4
PREMOULDED EXPANSION
JOINT FILLER
R=1"
R=2"
12"
1'-4"
10' 2'
2%
10'
2%
2'
1'1' PROFILE
LOCATION
MOUNTABLE CURB
5' SHOULDER
(SLOPE VARIES)
Scale: NTS
ROADWAY SECTION 1 (TYPICAL)14
FROM STA 00+00.00 TO 42+05.44 (ROAD A)
FROM STA 00+00.00 TO 03+14.90 (ROAD B)
FROM STA 05+05.03 TO 05+41+14 (ROAD B)
FROM STA 00+00.00 TO 05+37.76 (ROAD C)
FROM STA 00+00.00 TO 01+90.11 (ROAD D)
FROM STA 34+36.42 TO 00+67.83 (ROAD D1)
FROM STA 00+00.00 TO 13+78.00 (SHERIDAN RD)
5' SHOULDER
(SLOPE VARIES)
MOUNTABLE CURB
Scale: NTS
ROADWAY SECTION 3 (TYPICAL)16
4000 PSI CAST IN PLACE CONCRETE
REFER TO
PAVEMENT DETAIL
4" AGGREGATE BASE COURSE
95% COMPACTION
CONCRETE WALK
2% MAX CROSSSLOPE
NOTES:
1. MIN. 4000 PSI CONCRETE.
2. PROVIDE EXPANSION JOINTS @ 50'-0" O.C. NON-EXPANDING EXTRUDED EXP. JOINT MATERIAL.
3. PROVIDE TOOLED CONTROL JOINTS @ 10'-0" O.C.
4. MATCH LOCATION OF JOINTS WITH ADJACENT CONCRETE WALK.
24"
Scale: NTS
FLUSH CURB (TYPICAL)7
R=1/4" (BOTH SIDES)
12"
EXPANSION JOINT
COMPACTED SUBGRADE
95% COMPACTION
Scale: NTS
GRAVEL PATH SECTION (TYPICAL)5
6" M
IN
COMPACTED
AGGREGATE
COMPACTED SUBGRADE
TOP 12" COMPACTED TO 98%
FILL BENEATH COMPACTED TO 95%
1/2" RADIUS
3 - #4 REBAR CONT.
4" AGGREGATE BASE COURSE
95% COMPACTION
10"
24"
Scale: NTS
VALLEY GUTTER (TYPICAL)8
12"
1" BATTER
NOTES:
1. MIN. 4000 PSI CONCRETE.
2. 1/4" RADIUS EDGES.
3. PROVIDE EXPANSION JOINTS @ 50'-0" O.C. NON-EXPANDING EXTRUDED EXP. JOINT MATERIAL.
4. PROVIDE TOOLED 1-1/4" CONTROL JOINT @ DISTANCE MATCHING WIDTH OF WALK.
NOTES:
1. MIN. 4000 PSI CONCRETE.
2. PROVIDE EXPANSION JOINTS @ 50'-0" O.C. NON-EXPANDING
EXTRUDED EXP. JOINT MATERIAL.
3. PROVIDE TOOLED CONTROL JOINTS @ 10'-0" O.C.
EXISTING
ASPHALT
2%
PRIME COAT (MC-30)
@ 0.05 GAL/SY
24"
8"
1/4" R
1/4 " R
7"
2 - #4 CONTINUOUS
Scale: NTS
24" MOUNTABLE CURB (TYPICAL)6
NOTE:
1. ADJACENT ROADWAY NOT SHOWN FOR CLARITY.
2. MINIMUM LENGTH OF TRANSITION: 6'-0".
3. ADJUST DEPTH BETWEEN DEPTH OF MOUNTABLE
GUTTER AND FLUSH GUTTER.
Scale: NTS
MOUNTABLE TO FLUSH CURB TRANSITION (TYPICAL)10
4" AGGREGATE BASE COURSE
95% COMPACTION
TACK COAT CSS-IH
@ 0.05 GAL/SY
NOTES:
1. MIN. 4000 PSI CONCRETE.
2. CROSS SLOPE OF GUTTER SAME AS PAVEMENT.
3. PROVIDE EXPANSION JOINTS @ 50'-0" OC. NON-EXPANDING EXTRUDED
EXP. JOINT MATERIAL.
4. PROVIDE TOOLED CONTROL JOINTS @ 10'-0" O.C.
TACK COAT CSS-IH
@ 0.05 GAL/SY
NOTE:
1. MIN. 4000 PSI CONCRETE.
2. 1/4" RADIUS EDGES.
3. PROVIDE EXPANSION JOINTS @ 50'-0" O.C. NON-EXPANDING EXTRUDED EXP. JOINT MATERIAL.
4. PROVIDE TOOLED 1-1/4" CONTROL JOINT @ DISTANCE MATCHING WIDTH OF WALK.
AT ASPHALT ROADS,
APPLY TACK COAT
CSS-IH
@ 0.05 GAL/SY
11' 6"
2%
11' 6"
2%
PROFILE
LOCATION
FROM STA 03+14.90 TO 05+05.03 (ROAD B)
FROM STA 14+48.92 TO 21+01.37 (SHERIDAN ROAD) (TYPICAL)
11' 6" 11' 6" 2'
1'5' SHOULDER
(SLOPE VARIES)
5' SHOULDER
(SLOPE VARIES)
11' 6"
2%
11' 6"
2%
PROFILE
LOCATION
FROM STA 13+78.00 TO 14+48.92 (SHERIDAN ROAD)
FROM STA 21+01.37 TO 22+65.45 (SHERIDAN ROAD)
11' 6" 2'
1'
6" VERTICAL CURB
5' SHOULDER
(SLOPE VARIES)
5' SHOULDER
(SLOPE VARIES)
Scale: NTS
ROADWAY SECTION 2 (TYPICAL)15
NOTES
1. CONCRETE DRIVEWAY APRONS, LOADING ZONES AND
MAINTENANCE YARDS.
2. NEW CONCRETE SHALL BE SLOPED TO DRAIN, AND FINISHED
TO TIE TO ADJACENT GRADE.
3. CONCRETE TO BE PLACE 6" THICK AND FINISHED WITH TAMPS,
WOOD FLOATS AND STIFF-BRISTLED BROOMS.
4. CONCRETE WITH TRANSVERSE AND EXPANSION JOINTS TO BE
LOCATED AND BUILT TO MATCH EXISTING CONFIGURATION.
5. TOOLED 1-1/2" CONTROL JOINTS WITH 14" RADIUS EDGES.
6. TOOLED CONTROL JOINT SPACING FOR 6" SLAB IS 10 FEET.
CONFIGURE JOINTS TO CREATE RECTANGULAR,
SYMMETRICAL SECTIONS.
7. EXPANSION JOINT SPACING IS 30 FEET. CONFIGURE JOINTS
TO CREATE RECTANGULAR, SYMMETRICAL SECTIONS.
8. USE #4 EPOXY COATED DOWELS, 1"Ø BY 20" LONG, AT
CONSTRUCTION JOINTS WHERE BREAK IN POUR.
9. USE 12" EXPANSION JOINTS, 1' MIN FROM FLANGE EDGE AT
MANHOLES, CLEANOUTS, INLETS, AND OTHER STRUCTURES IN
CONCRETE.
X X X X X X X X X
SECTION VARIES
CONTROL JOINTS - 10'-0" (TYP.)
EXPANSION JOINTS - 30'-0" (TYP.)
6"
RIGID PAVEMENT
SECTION
6"
10"
3"
24" CONCRETE MOW STRIP AT YARD FENCE,
INSTALL FENCE AT CENTERLINE OF MOW
STRIP
2" FIBROUS EXPANSION
JOINT (TYP)
6" COMPACTED ABC AGGREGATE
98% MODIFIED PROCTOR
12" THICK SUBGRADE COMPACTED TO 98%
ASTM D1557 DENSITY
#4 SMOOTH EPOXY COATED DOWELS
INTO CURED CONCRETE AT 12" O.C..
PAINT END OF DOWEL. INSERT
DOWELS WITH NON-SHRINK EPOXY
GROUT. DOWELS TO BE 1"Ø BY 20"
LONG.
MIN. 6" THICK, MIN. 4000 PSI COMPRESSIVE STRENGTH
CONCRETE PAVEMENT
WELDED WIRE FABRIC REINFORCEMENT:
6X6-W2.9XW2.9 WWF
USE CHAIRS TO SUPPORT WWF
Scale: NTS
(HEAVY DUTY) CONCRETE MAINTENANCE YARD SLAB (TYPICAL)12
CLASS 2
GEOSYNTHETIC
(TYP.),
18" OVERLAP, W/
ANCHORS
ISOLATION/EXPANSION JOINT (TYP.):
CHAIN LINK FENCE MOW STRIP, BUILDING SLABS,
FOOTINGS ABUT YARD SLAB
4"
NOTES:
1. FOR WIDENING OR NARROWING OF ROADWAYS AND INTERSECTIONS, SEE CP SHEETS.
2. FOR MILL AND REPLACE VS. NEW CONSTRUCTION SEE CS SHEETS AND CP SHEETS.
Scale: NTS
MOUNTABLE TO VALLEY GUTTER TRANSITION (TYPICAL)11
NOTES:
1. FOR WIDENING OR NARROWING OF ROADWAYS AND INTERSECTIONS, SEE CP SHEETS.
2. FOR MILL AND REPLACE VS. NEW CONSTRUCTION SEE CS SHEETS AND CP SHEETS.
NOTES:
1. FOR WIDENING OR ALIGNMENT CHANGE OF ROADWAYS AND INTERSECTIONS, SEE CP SHEETS.
2. FOR MILL AND REPLACE VS. NEW CONSTRUCTION SEE CP SHEETS AND CS SHEETS.
3. SEE CS SHEETS FOR CURB AND GUTTERS TO BE INSTALLED, AND REQUIRED TRANSITIONS
FROM MOUNTIABLE CURB TO FLUSH OR VALLEY CURB.
x xxx
NOTES:
1. CONCRETE SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 4,000 PSI AT 28
DAYS AND PLACED WITH A 3-1/2" MAX. SLUMP
2. CONCRETE SHALL BE BROOM FINISHED U.N.O.
3. REFER TO PLANS FOR PLACEMENT AND
SPACING OF CONTROL JOINTS. SAWCUT
JOINTS WITHIN 8 HOURS OF FINISHING
CONCRETE.
4. ALL EXPOSED CONCRETE CORNERS SHALL
RECEIVE A 3/4" CHAMFERED EDGE
5. CONTRACTOR SHALL INSTALL CONDUIT
CONNECTION FOR UNDERGROUND HVAC OR
ELECTRICAL CONNECTION.CONCRETE SLAB
REINFORCED WITH
6X6-W2.4XW2.4 WWF.
SUBGRADE COMPACTED TO 98% MAX. DRY DENSITY ASTM
D698 (STD. PROCTOR) WITH COMPACTION WITHIN 3% OF
OPTIMUM MOISTURE CONTENT.
xxxxD = 9" D = 5"
ADJACENT SIDEWALK (TYP.)
4'-6" (TYP.)
3'-0" (TYP.)
MAINTENANCE PAD
SIZE PAD TO EQUIPMENT +
4-INCHES MIN. ON EACH SIDE
MAINTENANCE BUILDING
SIDEWALK
4" GAP BETWEEN
PAD AND BLDG. (TYP.)
Scale: NTS
ELEVATED CONCRETE MECHANICAL PAD (TYPICAL)13
NOTES:
1. ABUTMENT OF NEW ASPHALT TO EXISTING.
2. FOR INSTALL OF NEW ASPHALT AND FOR 2" DEPTH MILL AND REPLACEMENT (TYPICAL).
6" VERTICAL CURB OR
MOUNTABLE CURB AS
SHOWN ON PLANS
NEW ASPHALT
1' 1'
2 - #4 REBAR CONT.
1- 1/
4"
1/4" R
MEDIUM BROOM FINISH PERPENDICULAR TO DIRECTION
OF TRAVEL
1/4"
1/4" R
CONSTRUCTION JOINT
1- 1/
4"
XXXXXX XXXXXX
#4 EPOXY COATED DOWEL, 20",
DRILL AND EPOXY
PAINT AND OIL END OF
DOWEL
EXISTING CONCRETENEW CONCRETE
7"
TACK COAT CSS-IH
@ 0.05 GAL/SY
MOUNTABLE CURB (TYP.)
SEE 6/CS501
MIN. 6'-0" LONG TRANSITION FROM
MOUNTABLE CURB TO FLUSH CURB AND
GUTTER. SEE PLANS FOR TRANSITION
LOCATIONS.
FLUSH CURB (TYP.)
SEE 7/CS501
NOTE:
1. ADJACENT ROADWAY NOT SHOWN FOR CLARITY.
2. MINIMUM LENGTH OF TRANSITION: 6'-0".
3. ADJUST DEPTH BETWEEN DEPTH OF MOUNTABLE
GUTTER AND VALLEY GUTTER.
MOUNTABLE CURB (TYP.)
SEE 6/CS501
MIN. 6'-0" LONG TRANSITION FROM
MOUNTABLE CURB AND GUTTER TO
VALLEY GUTTER. SEE PLANS FOR
TRANSITION LOCATIONS.
VALLEY GUTTER (TYP.)
SEE 8/CS501
SIDEWALK OR LANDSCAPING
PER PLANS
SIDEWALK OR LANDSCAPING
PER PLANS
ASPHALT PAVEMENT
ASPHALT PAVEMENT
REFER TO
PAVEMENT DETAIL
COMPACTED SUBGRADE
95% COMPACTION
COMPACTED SUBGRADE
95% COMPACTION
COMPACTED SUBGRADE
95% COMPACTION
9"R
X X
NOTE:
1. INSTALL COMPACTED AGGREGATE SUITABLE FOR DRIVEWAY
THAT IS CLEAR OF DEBRIS/SOIL AND DISCOLORATION.
2. COORDINATE WITH CEMETERY ADMINISTRATION FOR PREFERRED
COLOR AND SIZE.
JTKHJM
CIVIL SITE DETAILS 1John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS501
Scale: NTS INSTALLATION - DUCTILE IRON PIPE IN SOIL (TYPICAL)3 Scale: NTS
VALVE BOX INSTALLATION DETAIL (TYPICAL)4
Scale: NTS
INSTALLATION - METER BOX DETAIL (TYPICAL)2Scale: NTS
INSTALLATION - FIRE FLOW METER BOX DETAIL (TYPICAL)1
Scale: NTS PRE-FABRICATED STEEL REINFORCEMENT (TYPICAL)5 Scale: NTS
THRUST BLOCK AT BENDS (TYPICAL)6 Scale: NTS
THRUST BLOCK DETAIL (TYPICAL)7
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 2
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS502
PIPE TRENCH TERMS (TYPICAL)1 Scale: NTS
REDUCER THRUST BLOCK (TYPICAL)2 Scale: NTS
DUCTILE IRON PIPE DETAIL (TYPICAL)3
Scale: NTS
TAP CONNECTION DETAIL (TYPICAL)4
Scale: NTS DITCH CHECK FOR SLOPES (TYPICAL)5 Scale: NTS
CROSS BLOCK SIDE VIEW (TYPICAL)6
Scale: NTS
DEAD END BLOCKING METHOD (TYPICAL)7
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 3
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS503
PATENT TAP EXCAVATION (TYPICAL)1
Scale: NTS
BLOWOFF/FLUSHING ASSEMBLY (TYPICAL)2
Scale: NTS
PIPE CURVE GEOMETRY (TYPICAL)6
Scale: NTS
TEST STATION CONNECTION (TYPICAL)3
Scale: NTS
CASING INSTALLATION DETAIL (TYPICAL)4
Scale: NTS
FIRE HYDRANT DETAIL (TYPICAL)5
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 4
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS504
NOTES:
1. DETAIL IS TYPICAL FOR CONSTRUCTION OF SPLITTER MANHOLE TO DIRECT
FLOW FIRST TO HYDRODYNAMIC SEPARATOR IN THE OFFLINE
CONFIGURATION.
2. BYPASS WEIR OVERFLOW TO BYPASS PIPE THROUGH OUTFALL STRUCTURE.
3. SIZE SPLITTER MANHOLE CASTING FOR LARGEST (DOWNSTREAM) PIPE USED.
4. WEIR LENGTH TO RUN WIDTH OF STRUCTURE.
5. SLOPE INVERTS TO DRAIN TO BOTH OUTLET PIPES.
6. OUTFLOW PIPE TO HYDRODYNAMIC SEPARATORS TO BE 12" DIAMETER,
REINFORCED CONCRETE PIPE, PER MSD REQUIREMENTS. CONSULT WITH
MANUFACTURER AND MSD FOR ANY CHANGE TO PIPE MATERIAL.
NOTES:
1. DETAIL IS TYPICAL FOR CONSTRUCTION OF SPLITTER MANHOLE TO DIRECT
FLOW FIRST TO HYDRODYNAMIC SEPARATOR IN THE OFFLINE
CONFIGURATION.
2. BYPASS WEIR OVERFLOW TO BYPASS PIPE THROUGH OUTFALL STRUCTURE.
3. SIZE SPLITTER MANHOLE CASTING FOR LARGEST (DOWNSTREAM) PIPE USED.
4. WEIR LENGTH TO RUN WIDTH OF STRUCTURE.
5. SLOPE INVERTS TO DRAIN TO BOTH OUTLET PIPES.
6. OUTFLOW PIPE TO HYDRODYNAMIC SEPARATORS TO BE 12" DIAMETER,
REINFORCED CONCRETE PIPE, PER MSD REQUIREMENTS. CONSULT WITH
MANUFACTURER AND MSD WITH ANY CHANGE TO PIPE MATERIAL.
7. COORDINATE SIZING OF MANHOLES FOR HYDRODYNAMIC SEPARATOR, WEIR
SPLITTER MANHOLE, AND OUTFLOW MANHOLE WITH MANUFACTURER AND
MSD.
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 5
Scale: NTS 4' DIAMETER HYDRODYNAMIC SEPARATOR OFFLINE CONFIGURATION (TYPICAL)1 Scale: NTS
OFFLINE CONFIGURATION FROM MANUFACTURER (TYPICAL)2
Scale: NTS SPLITTER MANHOLE W/ CONCRETE WEIR (TYPICAL)3 Scale: NTS
SPLITTER MANHOLE BYPASS WEIR, STRUCTURE LAYOUT (TYPICAL)4 Scale: NTS
OFFLINE STRUCTURE CONFIGURATION (TYPICAL)5
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS505
C
A6" 6"
E
D
6"
PLAN VIEW
DIA.
TO SUIT
12"
B
ELEVATION
1" CHAMFER
D
12"
E
NO. 4 BARS AT 12" O.C.
NO. 4 BARS AT 12" O.C.E.W.
BASE AND WALL
SECTION
DIMENSION SCHEDULE
PIPE
DIA.
WALL
OPENING A B C D E APPROX WEIGHTS
12" 20" 48" 48" 24" 12" 6" 3,990 LBS.
15" 24"
18" 28" 72" 60" 30" 12" 12" 6,575 LBS.
21" 30" 24" 34" 30" 42"
120" 72" 30" 12" 12" 12,250 LBS.
36" 48" 42" 54" 48" 64"
192" 84" 36" 12" 12" 24,450 LBS.
SPECIAL SIZES NOT LISTED CAN BE MFG. UPON REQUEST
(ON EXPOSED
EDGES)
STIRRUPS
CEMETERY FINISHED GRADE
CENTERLINE OF DRAINAGE DITCH
FROM PARKS DEPT. PROPERTY
NOTES:
1. COORDINATE SIZING AND FINAL DESIGN WITH MANUFACTURER FOR PRE-CAST HEADWALLS.
2. HEADWALL LOCATION IS AT EXISTING DITCH LINE. MAY BE REQUIRED TO ADJUST HEIGHT OF
STRUCTURE TO LINE UP PIPE INVERTS WITH DITCH LINE.
3. HEADWALL CONSTRUCTED FROM MIN. 4000 PSI CONCRETE @ 28 DAYS.
4. REBAR AND STIRRUPS SIZING ARE MINIMUM REQ.
5. TOP OF HEADWALL SHALL TIE FLUSH TO FINISHED GRADE ON THE CEMETERY PROPERTY. TAPER AND
ADJUST HEIGHT OF HEADWALL TO TIE TO FINISHED GRADE.
6. PERIMETER FENCE POSTS MOUNTED IN MOW STRIP. WHERE FENCE CROSSES TOP OF HEADWALL, ANCHORED IN TOP OF (FORMED) OR IMMEDIATELY BEHIND (MANUFACTURED) HEADWALL.
7. REGRADE DITCH TO TIE BACK TO HEADWALL.
(VARIES)
(VARIES)
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 6
Scale: NTS PRECAST CONCRETE MANHOLE (TYPICAL)1 Scale: NTS
PRECAST MANHOLE ON EX. CONT. FLOW ONLY(TYPICAL)2 Scale: NTS TYPICAL PRECAST MANHOLE TEE (TYPICAL)3 Scale: NTS
PRECAST MANHOLE STEP (TYPICAL)4
Scale: NTS CAST IRON COVER MANHOLE (TYPICAL)5 Scale: NTS
ADJUST EXISTING MANHOLE TO GRADE (TYPICAL)6 Scale: NTS SINGLE STREET INLETS PRECAST CONCRETE (TYPICAL)7 Scale: NTS
STRAIGHT HEADWALL WITH FOOTING (TYPICAL)8
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS506
22 12 "
4"
8"
6"
6"
VA
R
IE
S
D
D + 18
GUTTER FLOW LINE
CHANNEL
BENCH
BENCH
SLOPE INVERT TO OUTLET PIPE
PLAN VIEW
NOTES
1. USE TIDEFLEX TF-1 ATUNDERDRAIN OUTFALLS TO BE INSTALLED AT PRIVATE,
VA OWNED, INLET STRUCTURES ABOVE THE INVERT ELEVATION OF
STORMWATER PIPE.
2. USE CMU - CHECKMATE ULTRAFLEX IN-LINE CHECK VALVES AT UNDERDRAIN
OUTFALLS TO BE INSTALLED AT MSD MAINTAINED MANHOLE STRUCTURES,
LOCATED IN MSD EASEMENT AND/OR MSD MAINTAINED STRUCTURE.
NOTES
1. UNDERDRAIN OUTFALLS TO BE INSTALLED AT INLET STRUCTURES ABOVE THE INVERT
ELEVATION OF STORMWATER PIPE.
2. TRAFFIC RATED ROLL GRATE AT MOUNTABLE CURB, TYPICAL INSTALL.
3. WHERE INSTALLING NEW STORMWATER STRUCTURES ON EXISTING MSD OWNED PIPE
NETWORK, COORDINATE STRUCTURE SIZING WITH MSD.
4. TYPICAL MINIMUM 48"X48" SQUARE INLET STRUCTURE FOR ROLL GRATE CURB INLET
STRUCTURES.
5. ALL STORMWATER STRUCTURE SHALL BE 48" MINIMUM INSIDE DIAMETER.
NOTES
1. NEENAH FOUNDRY R-3237-1 OR APPROVED EQUAL.
TIDEFLEX TECHNOLOGIES SERIES
TF-1, OR APPROVED EQUAL
CONNECT TO PVC WITH STAINLESS
STEEL TENSION RING. SEE STORM
STRUCTURE PROFILES FOR
LOCATIONS.
7.5" 33" 7.5"
7.
5"
7.
5"
6-INCH (MIN.) THICK
REINFORCED
CONCRETE
NOTES:
1. NEENAH FOUNDRY R-2557-A OR APPROVED EQUAL.
2. CONCRETE LID SHALL BE TRAFFIC RATED AND
4000 PSI MIN.
3. COLLAR ELEVATION SHALL MATCH FINISHED
GRADE, AND SLOPED TO PROVIDE POSITIVE
DRAINAGE TO INLET, TO A MIN. 2%. SMOOTH
TRANSITION TO ADJACENT FINISHED GRADE.
4. DIMENSIONS ARE TYPICAL FOR A 4-FOOT SQUARE
STORMWATER STRUCTURE. ADJUST LID SIZE TO
MATCH STRUCTURE.
INLET
GRATE
GRASS GRASS
SLOPESLOPE
DRAINAGE PATH AT DITCH LINE
SLOPE INVERT TO OUTLET PIPE
TIDEFLEX CMU - CHECKMATE INLINE
CHECK VALVE OR APPROVED EQUAL
CONNECT TO PVC WITH STAINLESS
STEEL TENSION RING. SEE STORM
STRUCTURE PROFILES FOR
LOCATIONS.
PRIVATE
STRUCTURE
MSD
STRUCTURE
John Gallup & Associates, LLC 3225 Shallowford Road NE Suite 830 Marietta, GA 30062 770.321.4040
JG&A
Corp. License FL001428603
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseA/E OF RECORD STAMP
321 4 5 6 7 8 9 10
JEFFERSON BARRACKS NATIONAL
CEMETERY SYLVAN SPRINGS
DEVELOPMENT ON NEW LAND
2900 Sheridan Rd, St. Louis, MO, 63125 Project Director
NOVEMBER 18, 2024Revisions: Date:
CONSULTANTCONSULTANTCONSULTANTCONSULTANT
N/A
Environment & Infrastructure Solutions, Inc.
1075 Big Shanty Road, NW, Suite 100 Kennesaw, Georgia 30144
(770) 421-3400
Aqua Engineering Inc.
375 E. Horsetooth Road, Building 2-202 Fort Collins, CO 80525-3196
852-042 ofDwg.
Atriax Pllc 703 Main Avenue S.W.
Hickory, NC 28602 828-315-9962 Corp. License - 2019014628
1 0 5 3 T E N T H A V E N U E S A N D I E G O , C A 9 2 1 0 1 P H O N E 6 1 9 . 2 3 8 . 3 8 1 1 www.davyarchitecture.com
CONSULTANT
BID DOCUMENTS
MSD PROJECT NUMBER 24MSD-00322
MSD BASE MAP: 29-H
07/08/2025
JTKHJM
CIVIL SITE DETAILS 7
Scale: NTS AREA INLET PRECAST CONCRETE (TYPICAL)2 Scale: NTS
ROLL GRATE CURB INLET (TYPICAL)3
Scale: NTS UNDERDRAIN CHECK VALVE (TYPICAL)6 Scale: NTS
CONCRETE INVERT (TYPICAL)7
Scale: NTS
STORMWATER STRUCTURE SIZING W/ PIPE SIZE (TYPICAL)5
Scale: NTS REINFORCED CONCRETE PIPE INSTALLATION (TYPICAL)1 Scale: NTS
DROP GRATE AREA INLET (TYPICAL)4
Scale: NTS STEEL REQ. FOR GRATE INLET SEAT (TYPICAL)8 Scale: NTS
STEEL REQ. FOR 4 WAY AREA INLET (TYPICAL)9
Docusign Envelope ID: 1BA9151A-8F27-4B9F-B284-54CC709273A4
AutoCAD SHX Text
CS507
File details come from the government source that posted it. Updated .