MTOC MODIFICATIONS 1
ADDENDUM A 2
Contents 3 General Scope of Work ................................................................................................................................................................ ...... 3 4
1. SUMMARY OF WIRING SPECIFICATIONS AND EQUIPMENT INSTALLATION ............................................ 3 5
2. LABELING ................................................................................................................................................................................ 4 6
a. Panels .................................................................................................................................................................................... 4 7
b. Cables/Wiring ................................................................................................................................................................... 4 8
Detailed Scope of Work ..................................................................................................................................................................... 4 9
1. EXTERNAL CABLING ........................................................................................................................................................... 4 10
a. Mast ....................................................................................................................................................................................... 4 11
b. Roof ........................................................................................................................................................................................ 6 12
c. Exterior I/O panels .......................................................................................................................................................... 6 13
2. CONTROL ROOM ................................................................................................................................................................... 7 14
a. Rack cable management................................................................................................................................................ 7 15
b. Remove all non-essential cabling .............................................................................................................................. 7 16
c. Replace/re-run all necessary cabling ...................................................................................................................... 7 17
d. Install and wire video monitor ................................................................................................................................... 8 18
e. Install all rack mounted equipment ......................................................................................................................... 8 19
f. Fabricate, install and wire rack mounted RF patch panel............................................................................. 11 20
g. Fabricate, install and wire rack mounted data patch panel (GFE) .......................................................... 12 21
h. AC electrical distribution for equipment racks ................................................................................................. 12 22
3. WORK AREA. Remove all non-essential cabling and replace as listed below .......................................... 13 23
a. AC electrical wiring ....................................................................................................................................................... 13 24
b. Computer/Extron Patching Station ........................................................................................................................ 14 25
d. Data. ................................................................................................................................................................ ..................... 14 26
e. Video Monitors ................................................................................................................................................................ 14 27
f. Audio System ................................................................................................................................................................ ... 15 28
4. ADDITIONAL MODIFICATIONS ..................................................................................................................................... 15 29
a. Control Room ................................................................................................................................................................ ... 15 30
b. Work Area ......................................................................................................................................................................... 15 31
c. Exterior .............................................................................................................................................................................. 16 32
5. PROJECT LOGISTICS AND ACCEPTANCE .................................................................................................................. 17 1
6. WARRANTY ........................................................................................................................................................................... 18 2
7. DOCUMENTATION ............................................................................................................................................................. 18 3
8. ATTACHMENTS ................................................................................................................................................................... 19 4
MTOC Refurbishment/Upgrade 1
General Scope of Work 2 The Federal Bureau of Investigation’s Technical Response Unit (TRU), Quantico, VA is soliciting quotes for the 3 refurbishment/upgrade of a mobile command post vehicle (MCPV). The MCPV is a 2007 Freightliner M-2/112 4 chassis with a custom 22’ command box manufactured by Gerling, Inc. The command box has two manual 5 slide-outs (rear and passenger side). The MCPV is equipped with a 30’ Wilburt pneumatic mast and 20Kw 6 Kohler generator. The scope of work includes a partial electrical re-wire and a complete re-wire of radio 7 frequency and audio/video coaxial, and data wiring, including the mast; the installation of vendor and 8 government furnished equipment; the reconfiguration of interior workspace; the construction and installation 9 of storage cabinets; the installation of an audio/video system; the installation of exterior lighting and camera 10 systems; and waterproofing the roof of the vehicle. All wiring will conform to the specifications contained 11 herein and correspond to as-built wiring diagrams furnished by the vendor. 12
1. SUMMARY OF WIRING SPECIFICATIONS AND EQUIPMENT INSTALLATION 13
a. Remove all non-essential/obsolete cable 14
i. Control room, work area, mast. 15
b. Supply (as indicated) and install cabling/wiring 16
i. Control room, work area, mast. All cables will be protected from chafing and 17 abrasion. Grommets will be used to protect cabling when passing through 18 sheet metal, bulkheads, etc. All cabling will be labeled at the source and 19 destination with durable labels. Cabling will be run in conduit, raceway or flex 20 duct in such a way to provide easy access for technicians to make future 21 modifications. Cable runs will be securely strapped alleviating stress on cables. 22 Provide detailed as-built wiring diagrams in hard and soft copy. 23
1. Radio Frequency (RF) Coaxial 24
a. LMR-240 Ultra Flex 25
b. Connectors – Exterior grade, water/weather proof, adhesive 26 lined heat shrink, center pin solder, compression type 27
2. Data Category 6 (CAT-6) (GFE) 28
a. CAT-6A F/UTP (ScTP) 29
b. Color corresponds to function 30
c. Use T568B termination standard (unless otherwise 31 specified) 32
d. Connectors 33
i. RJ-45 – Interior 34
ii. L-Com Model # ECRH3201U00 - Exterior 35
3. Audio/Video Coaxial 36
a. RG-6 shielded 37
4. AC electrical wiring 38
a. 14 Gauge, 3 conductor SJOOW, 300 volt electric cable 39
b. Outlet type specified by location 1
c. Assess mechanical functionality of mast 2
d. Install equipment in control room rack/configure rack space to accept customer 3 installed equipment 4
i. Audio/video systems 5
ii. RF systems 6
1. Fabricate, install and wire an RF patch panel in equipment rack 7
iii. Data network systems 8
1. Fabricate, install and wire a data patch panel in equipment rack 9
iv. Electrical power systems 10
e. Fabricate, install and wire an RF I/O panel on exterior of vehicle 11
f. Fabricate, install and wire a data I/O panel on exterior of vehicle 12
g. Install antenna on mast and roof of vehicle as specified 13
i. Cellular 14
ii. Over the Air television 15
iii. Satellite television 16
h. Fabricate and install cabinetry as specified 17
i. Control room storage cabinet 18
ii. Work area shelving unit 19
i. Modify/install work tables as specified 20
j. Supply and install LED flood lights on rear of vehicle 21
2. LABELING 22
a. Panels 23
i. Metal photo or etching for text/numerals 24
ii. Black background/white lettering 25
b. Cables/Wiring 26
i. Non-smear cable wrap labels 27
ii. Label both ends 28
Detailed Scope of Work 29
1. EXTERNAL CABLING 30
a. Mast 31
i. Perform evaluation of mechanical function of pneumatic mast 32
1. Provide customer with findings and solutions (written estimates) 33
ii. Remove all existing/original cable from mast 34
iii. Remove existing NYCOIL from mast 35
iv. Install new NYCOIL 36
1. NYCOIL large enough to accommodate the following cabling: 1
a. LMR-240 coaxial x 4 2
i. RF cables 3
1. X 3 4
2. “N” TYPE bulkhead jack connectors at mast 5
3. Water/weather proof 6
4. Terminated with bulkhead jack into RF patch 7 panel in equipment rack 8
a. Labeled Mast RF #1 9
b. Labeled Mast RF #2 10
c. Labeled Mast RF #3 11
ii. Cellular modem antenna wiring 12
1. X 1 13
2. Terminated at cellular antenna on mast head and 14 at cellular modem in equipment rack using an 15 SMC connector 16
3. All external cable and connectors will be 17 water/weather proof 18
b. RG-6 or equivalent 75ohm cable (video/TV) x 2 19
i. OTA antenna 20
1. terminated at Over-the-Air tuner/controller 21
ii. Down link/spare 22
1. X 1 23
2. Terminated at RF patch panel in equipment rack 24
a. Labeled ISR ANT 25
c. CAT 6A F/UTP (ScTP) x 4 26
i. UV exterior grade cabling 27
ii. Use L-Com ECRH32001U00 connectors on mast 28
iii. GRAY/BLACK 29
1. Camera Video 30
a. X 2 31
b. Terminated into Pelco Camera DVR in 32 equipment rack 33
2. Spare 34
a. X 2 35
b. terminated at data patch panel in 36 equipment rack 37
i. Patch panel labeled Mast Data #1 38
ii. Patch panel labeled Mast Data #2 39
d. 24VAC X 1 40
i. Split at mast top to be utilized for two mast cameras 41
ii. Terminated at Pelco power supply in equipment rack 1
v. Install new mast-top bracket (GFE) 2
1. Mount and wire HD Over The Air (OTA) TV antenna (GFE) 3
2. Mount and wire IP-based cameras on mast 4
a. Pelco 5
i. X 2 6
ii. Model to be determined 7
3. Mount and wire cellular modem antenna (GFE) on mast bracket 8
b. Roof 9
i. Supply, install and wire new DIRECT TV system 10
1. Roof mounted Dish antenna 11
a. WINGARD Satellite Television system 12
i. DIRECT TV SYSTEM, SK-SWM-3 13
ii. Self-acquiring, Self-locating 14
iii. Run all cabling to controller located in equipment racks 15
1. All external cable and connectors will be 16 water/weather proof 17
ii. Install secondary cellular modem antenna (GFE) 18
1. Run cabling to equipment rack 19
a. Terminated into Cellular Modem secondary antenna using 20
SMC connector 21
1. All external cable and connectors will be 22 water/weather proof 23
c. Exterior I/O panels 24
i. Use the two existing through-panels on driver’s side. Install keyed locks on 25 both doors (keyed alike) 26
ii. Design and fabricate I/O box in the forward most existing opening 27
1. RG-6 Coaxial 28
a. X 2 “F” type connectors 29
i. One terminated in RF patch panel in equipment rack 30
ii. One terminated at power splitter for A/B video 31 switches in equipment rack 32
2. LMR-240 Coaxial 33
a. X 3 BNC connectors 34
b. All three terminated at the RF patch panel in the equipment 35 rack 36
iii. Design and fabricate I/O box in the rear most existing opening 37
1. CAT-6 38
a. X 3. One each GREEN, RED, WHITE 39
b. Terminated at data patch panel in equipment rack 40
c. Use L-Com Item # ECRH3201U00 jacks 1
d. All cables will be labeled and color coded to match data 2 patch panel jacks. 3
2. Add pass-thru mouse hole 4
a. Protective edge to prevent chaffing 5
b. With attached cap/cover 6
2. CONTROL ROOM 7
a. Rack cable management 8
i. Individual cable management 9
1. Cable management system for floor and slide-out racks 10
a. Cable track or movable conduit 11
b. Cable bundles, tracks and large runs 12
i. Label cable bundles 13
1. list all individual cables in bundle on drawing 14
ii. Label cable tracks 15
1. list all individual cables in track on drawing 16
b. Remove all non-essential cabling 17
c. Replace/re-run all necessary cabling 18
i. Audio/video 19
1. RG-6 (GFE) 20
2. HDMI (GFE) 21
3. Extron Twisted Pair (GFE) 22
ii. Data 23
1. CAT 6A F/UTP (ScTP) (SHIELDED) (GFE) 24
a. Color as directed for identification of network 25
i. WHITE network 26
ii. GREEN network 27
iii. RED network 28
iv. GRAY/BLACK (Auxiliary cables) 29
v. BLUE (Extron) 30
b. RJ45 jacks color coded to match cables (GFE) 31
i. WHITE network 32
ii. GREEN network 33
iii. RED network 34
iv. GRAY/BLACK (Auxiliary cables) 35
v. BLUE (Extron) 36
vi. Connectors will be punch down type 37
c. Cable stress relief on both ends (min 1 foot each) 38
2. CAT-6 (SHIELDED) patch cables 39
i. 1 foot 1
1. WHITE network 2
a. X 20 3
2. GREEN network 4
a. X 20 5
3. RED network 6
a. X 20 7
ii. 3 feet 8
1. WHITE network 9
a. X 10 10
2. GREEN network 11
a. X 10 12
3. RED network 13
a. X 10 14
d. Install and wire video monitor (GFE) 15
i. 32” LED 16
ii. Mounted on wall above rear work bench 17
iii. HDMI directly to the Extron in equipment rack 18
iv. RG-6 directly to A/B switch (GFE) in equipment rack 19
v. Extend monitor’s rear ports to small patch panel located under video monitor 20
1. Composite 21
2. HDMI 22
3. USB 23
4. CAT-6 24
e. Install all rack mounted equipment (per provided drawing) 26
i. Install and wire Cellular Modem (GFE) 27
1. To Mast 28
a. LMR-240 coaxial 29
b. Terminated into the cellular modem primary antenna using 30 an SMC connector 31
c. All external cable and connectors will be water/weather 32 proof 33
2. To Roof 34
a. LMR-240 coaxial 35
b. Terminated into the cellular modem secondary antenna port 36 using an SMC connector 37
c. All external cable and connectors will be water/weather 38 proof 39
ii. Install and wire Over the Air (OTA) digital tuner and antenna controller 1
1. Winegard Razar RZ-8500 System 2
2. Controller mounted in equipment Rack #2 (per provided drawing) 3
(GFE) 4
3. Output wired to Over the air (OTA) power splitter output (GFE) 5
4. Audio/Video output to EXTRON CROSSPOINT 1600 switcher (GFE) 6
5. Control from Extron system 7
iii. Install and wire EXTRON XTP Crosspoint 1600 system (GFE) 8
1. Program and integrate with all associated audio/video equipment 9
2. Install and wire Extron DMP 44 LC Audio Mixer 10
3. Install and wire Extron ICPC control processor 11
4. Install and wire Extron audio amplifier 12
5. Utilize RS232 for equipment control when available 13
6. Provide soft copy of program 14
7. Provide hard copy of wiring diagram 15
iv. Supply, install and wire satellite TV antenna controller 16
1. Controller mounted in equipment rack #2 (per provided drawing) 17
2. Run all wiring/cabling between antenna and controller 18
3. All external connectors will be weather/water proof 19
4. All through points will be weather/water proof 20
v. Install and wire satellite TV receiver boxes X 2 (GFE) 21
1. Mounted in equipment rack #2 (per provided drawing) 22
2. Run all wiring/cabling between Sat TV antenna controller and receiver 23 boxes 24
3. Audio/Video output to EXTRON CROSSPOINT 1600 switcher 25
4. Control from Extron system 26
vi. Install and wire rack mounted AM/FM/CD player (GFE) 27
1. Denon DN-300Z 28
2. Audio output to EXTRON CROSSPOINT 1600 switcher 29
3. Control from Extron system 30
vii. Install and wire rack mounted Blue Ray player (GFE) 31
1. Denon DN-500DB 32
2. Audio/Video output to EXTRON CROSSPOINT 1600 switcher 33
3. Control from Extron system 34
viii. Install and wire rack mounted speakers (GFE) 1
1. Whiteridge Industries CRM-1 Confidence 2
2. Audio output from EXTRON CROSSPOINT 1600 switcher. Control from 3
Extron system 4
ix. Install and wire rack mounted network patch panels (GFE). All RJ45 connectors will 5 be punch down type. Utilize T568B (termination standard) 6
1. GREEN network 7
a. Located in Rack #1 (per supplied drawing) 8
b. CAT-6 Shielded Patch panel, 24-port, 1U 9
i. labeled 1 – 24 10
ii. GREEN RJ45 Connectors 11
iii. GREEN CAT 6A F/UTP (ScTP) 12
1. Service loop at both ends (min 1’) 13
2. Patch panel numbering to correspond with 14 workstation jack numbering. 15
2. WHITE network 16
a. Located in Rack #1 (per supplied drawing) 17
b. CAT-6 Shielded Patch panel, 24-port, 1U 18
i. labeled 1 – 24 19
ii. WHITE RJ45 connectors 20
iii. WHITE CAT 6A F/UTP (ScTP) 21
1. Service loop at both ends (min 1’) 22
2. Patch panel numbering to correspond with 23 workstation jack numbering. 24
3. Jacks 22 - 24 will be utilized for the Motorola 25 radio switch 26
3. RED network 27
a. Located in Rack #1 (per supplied drawing) 28
b. CAT-6 Shielded Patch panel, 24-port, 1U 29
i. labeled 1 – 24 30
ii. RED RJ45 connectors 31
iii. RED CAT 6A F/UTP (ScTP) 32
1. Service loop at both ends (min 1’) 33
2. Patch panel numbering to correspond with 34 workstation jack numbering. 35
x. Supply, install and wire Video Monitor A/B Switches 36
1. Install in Rack #2 (per supplied drawing) 37
2. Utilize RG-6 cabling 38
3. Quantity X 5 39
a. Control room TV 1
b. Outside TV 2
c. Driver side rear TV 3
d. Driver side middle TV 4
e. Driver side front TV 5
4. Inputs for A/B Switches 6
a. Control room TV A/B Switch to: 7
i. Over the air antenna (OTA) power splitter 8
ii. I/O panel power splitter 9
b. Outside TV A/B Switch to: 10
i. Over the air antenna (OTA) power splitter 11
ii. I/O panel power splitter 12
c. Driver side rear TV A/B Switch to: 13
i. Over the air antenna (OTA) power splitter 14
ii. I/O panel power splitter 15
d. Driver side middle TV A/B Switch to: 16
i. Over the air antenna (OTA) power splitter 17
ii. I/O panel power splitter 18
e. Driver side front TV A/B Switch to: 19
i. Over the air antenna (OTA) power splitter 20
ii. I/O panel power splitter 21
xi. Install and wire Pelco video DVR DX4700/4800 (GFE) 22
1. Wired to mast cameras 23
xii. Install and wire 24 port Cisco data switches x 3 (GFE) 24
1. GREEN, RED, WHITE networks 25
xiii. Configure rack space for the following GFE per attached rack diagram: 26
1. Two Cisco routers 27
2. Network encryptor 28
3. Motorola consolette radio and switch 29
f. Fabricate, install and wire rack mounted RF patch panel 31
i. From forward most driver’s side exterior I/O panel: 32
1. LMR-240 x 3, BNC connectors 33
a. Labeled match outside connectors 34
i. EXT RF #1 35
ii. EXT RF #2 36
iii. EXT RF #3 37
2. RG-6 Video x 1. 38
a. Labeled to match outside connectors 1
i. EXT Video #1 2
ii. From the mast: 3
1. LMR-240 x 4. 4
a. RF x 3 labeled: 5
i. Mast RF #1 6
ii. Mast RF #2 7
iii. Mast RF #3 8
2. RG-6 Video 9
a. X 1 10
i. Labeled: ISR ANT 11
g. Fabricate, install and wire rack mounted data patch panel (GFE) 12
i. Connectors labeled at patch panel 13
ii. Through connectors can be utilized 14
1. Console cable (GFE) 15
a. RED Router 16
i. Labeled RED Router Console 17
b. RED Switch 18
i. Labeled RED Switch Console 19
c. GREEN Router 20
i. Labeled GRN Router Console 21
d. GREEN Switch 22
i. Labeled GRN Switch Console 23
e. WHITE Switch 24
i. Labeled WHT Switch Console 25
2. Cellular modem data output 26
a. Labeled RAVEN 27
3. CAT-6 x 5. 28
a. From rear most driver’s side exterior I/O panel x 3 29
i. Labeled and color coded to match exterior I/O panel 30
1. EXT Data #1 31
2. EXT Data #2 32
3. EXT Data #3 33
b. From Mast x 2, labeled: MAST Data #1 and MAST Data #2 34
h. AC electrical distribution for equipment racks 35
i. AC Power boxes mounted on rear of racks 36
1. Supplied directly from breaker panel 37
a. Each box supplied by a different 20amp circuit 38
ii. Uninterruptible Power Supply (GFE) x 2 39
1. Utilized to power RAPTOR outlet strips 40
a. Not to power Motorola 1
2. Located in front of racks as per provided drawing 2
iii. RAPTOR 1U rack mounted AC outlet strips for all equipment 3
1. X 3 4
2. Power supplied from UPS 5
3. Location per provided drawing 6
3. WORK AREA. Remove all non-essential cabling and replace as listed below 7
a. AC electrical wiring 8
i. Existing AC wiring will remain. Where necessary, new AC wiring will be run 9 in Hubbell raceway 10
ii. Re-install power strips under desk 11
1. X 1 per desk 12
a. Driver side desk 13
b. Middle desk 14
c. Passenger side desk 15
iii. Replace and/or install outlets at each individual station 16
1. Driver’s side wall. 17
a. AC 15amp plugs w/dual USB 4amp plugs (GFE) 18
i. X 4 for work stations, X 1 for printer shelves. Spacing 19 to be determined pre-production. 20
ii. Mounted in/on wall 21
iii. Duplex AC outlet with dual USB plugs 22
2. Middle work table 23
a. AC 15amp plugs w/dual USB 4amp plugs (GFE) 24
i. X 5 stations. Spacing to be determined pre-25 production. 26
ii. Mounted in table top along with data jacks. 27
iii. Duplex AC outlet with dual USB plugs 28
3. Passenger’s side wall 29
a. AC 15amp plugs w/dual USB 4amp plugs (GFE) 30
i. X 4 stations. Spacing to be determined pre-31 production. 32
ii. Mounted in/on wall 33
iii. Duplex AC outlet with dual USB plugs 34
4. Rear wall (control room) 35
a. AC 15amp plugs and USB 4amp plugs (GFE) 36
i. X 2 stations 37
ii. Change existing quad AC outlets x 2 to duplex AC 38 outlet with dual USB plugs x 2 39
b. Computer/Extron Patching Station 2
i. Middle work table 3
1. Towards rear of vehicle 4
2. Utilizing an XTP T UWP 202 HDMI/VGA Extron box 5
ii. Cables will be terminated at the Extron Crosspoint 1600 6
iii. Cable stress relief at both ends (min 1 foot each) 7
c. Install audio/video cable to Video Monitors 8
i. Install RG-6 (GFE) 9
1. From rack mounted A/B switch to corresponding TV 10
ii. Install HDMI (GFE) 11
1. From Extron 1600 to corresponding TV 12
d. Data. All RJ45 jacks will be punch down type. RJ45 jacks to match cable/network wiring 13 color. 14
i. Work stations 15
1. CAT 6A F/UTP (ScTP) shielded 16
a. X 3 jacks per box/workstation 17
i. WHITE network 18
ii. RED network 19
iii. GREEN network 20
2. Driver’s side work stations x 4 21
a. WHITE, GREEN and RED networks 22
3. Driver’s side printer shelves x 1 23
a. WHITE, GREEN and RED networks 24
4. Middle work stations x 5 25
a. WHITE, GREEN and RED networks 26
b. In recessed junction boxes containing AC/USB outlets 27
c. Install one Extron XTP T UWP 202 HDMI/VGA box 28
i. Rear of table top (see 3b. above) 29
5. Passenger side work stations x 4 30
a. WHITE, GREEN and RED network 31
6. Rear control room x 2 32
a. WHITE, GREEN and RED networks 33
b. On rear wall 34
e. Video Monitors 35
i. Driver’s side 48” x 3 36
1. Install and wire 48” video monitors (GFE) 37
a. HDMI (GFE) 38
i. Terminated in the Extron system 39
b. RG-6 1
i. Wired to A/B switch mounted in equipment rack (GFE) 2
c. Extend monitor’s rear ports to small patch panel located 3 under video monitor 4
i. Composite 5
ii. HDMI 6
iii. USB 7
iv. CAT-6 8
ii. Rear wall (control room) 32” 9
2. Install and wire 32” video monitor (GFE) 10
a. HDMI (GFE) 11
i. Terminated in the Extron system 12
b. RG-6 (utilize existing RG-6) 13
i. Wired to A/B switch mounted in equipment rack (GFE) 14
c. Extend monitor’s rear ports to small patch panel located 15 under video monitor 16
i. Composite 17
ii. HDMI 18
iii. USB 19
iv. CAT-6 20
f. Audio System 21
i. House Speakers (GFE) 22
1. Kramer Galil 4-C speakers x 4 23
2. Install speakers in ceiling of work area 24
3. Install volume control on rear wall of work area (GFE) 25
a. Customer designated location 26
4. Wired to Extron Amplifier XPA 1002 (GFE) 27
4. ADDITIONAL MODIFICATIONS 28
a. Control Room 29
i. Design, fabricate and Install cabinet under Control room work bench to house 30
15 laptop computers (General Dynamics 6000) and 4 VOIP phones 31 (make/model to be provided by customer) 32
b. Work Area 33
i. Design, fabricate and install shelving system at rear most end of driver’s side 34 work table (size and final location to be approved by customer). 35
1. Install two shelves with heavy duty, locking extension slides for GFE 36 printers 37
ii. Permanently mount middle work table to floor and run AC/data wiring as described 1 herein. 2
iii. Design and permanently mount driver’s side work table flush against the driver’s side 3 wall and hard mount to the floor. 4
1. Work table will span the entire length of the wall, custom configured 5 around the wall mounted monitors. 6
c. Exterior 7
i. Video monitor 48” 8
3. Install and wire 48” video monitor (GFE) 9
d. HDMI (GFE) 10
i. Terminated in the Extron system 11
e. RG-6 (utilize existing RG-6) 12
i. Wired to A/B switch mounted in equipment rack (GFE) 13
f. Extend monitor’s rear ports to small patch panel located 14 under video monitor 15
i. Composite 16
ii. HDMI 17
iii. USB 18
iv. CAT-6 19
ii. Roof coating 20
1. Thermal/UV load resistant coating 21
iii. Replace weather stripping around work area entry doors to ensure proper seal. 22
iv. Rear flood lights 23
1. Supply and install LED Flood lights 24
2. Dual switched to turn on when: 25
a. Vehicle transmission is shifted into reverse 26
b. On/off switch in control room 27
3. Comparable to WHELEN 600 series (24 diode) 28
4. X 2 Mounted high on truck 29
a. Driver side X1 30
b. Passenger side X1 31
v. Rear view camera/dashboard monitor 33
1. Test functionality 34
2. Provide repair estimate if necessary 35
5. PROJECT LOGISTICS AND ACCEPTANCE 2
a. Vehicle will be transported to/from the Vendor by the customer (at customer’s 3 expense) 4
b. Vendor may move truck within/around their facility to facilitate work. Vendor 5 assumes responsibility for any damage when the in possession of the vehicle.. 6
c. Customer will conduct site visits to the vendor location (at customer’s expense) for 7 project kick-off meeting, periodic inspections, and final acceptance. 8
d. Customer will conduct a comprehensive, all-inclusive final inspection prior to 9 acceptance. A complete acceptance check-off sheet will be generated by the 10 customer and utilized for the acceptance testing. Testing will include but is not 11 limited to the following: 12
i. Test all data cables 13
ii. Test all data connectors 14
1. Work stations 15
2. Routers 16
3. Switches 17
4. Patch panels 18
iii. Test all video monitor connections 19
1. Satellite 20
2. Over-the-Air 21
iv. Test cellular modem connections 22
1. Mast antenna 23
2. Roof antenna 24
3. Data connections 25
v. Test and verify operation of Extron XTP system 26
1. Properly programmed 27
2. Proper naming of inputs/outputs 28
3. Proper connectivity 29
vi. Test proper operation of camera system 30
1. Mast cameras 31
a. Proper cabling 32
b. Proper connectivity 33
c. Proper operation 34
vii. Truck testing 35
1. 150 mile road test (minimum) 36
a. Combination of interstate and rural 37
2. Verify proper operations of camera system (back-up) 38
3. Verify proper driving lights operation 39
4. Verify proper mast operation 40
a. Mast platform 1
b. Nycoil 2
c. Cabling 3
d. Cameras 4
e. Antennas 5
6. WARRANTY 6
a. Vendor electrical systems 7
i. 2 years 8
b. Vendor material and workmanship 9
i. 1 year 10
c. Any vendor applied paint 11
i. 5 years 12
d. OEM parts and equipment 13
i. Original manufacturer’s warranty to begin at vehicle acceptance. 14
7. DOCUMENTATION 16
a. Vendor Provided As-Built Schematics 17
i. Documenting and labeling of all wiring and cable track/run systems 18
1. Power 19
2. Data 20
3. Audio 21
4. Video 22
5. Equipment rack elevation 23
ii. Schematics will include, but not limited to 24
1. Cable labels 25
a. Both ends match 26
i. Power 27
ii. Data 28
iii. Audio 29
iv. Video 30
2. Bundled Cable Labels 31
a. List all wires/cables inside cable track/run 32
3. Color code of cables 33
a. Power 34
b. Data 35
i. GREEN network 36
ii. RED network 37
iii. WHITE network 38
iv. BLUE Extron 39
v. GRAY/BLACK (Auxiliary) 40
c. Audio 1
d. Video 2
4. Compartments pass-thrus and junctions 3
a. Power 4
b. Data 5
c. Audio 6
d. Video 7
b. Hard and soft copy of schematics will be provided to customer 8
i. Quantity 9
1. Hard copy D size 10
a. X 2 (min) 11
2. Hard copy laminated 12
a. X 1 (min) 13
3. Soft copy 14
a. X 1 (min) 15
i. Thumb Drive 16
ii. Formatted as Visio design software 17
8. ATTACHMENTS 18
a. Equipment Rack (Rack Elevation) 19
b. A/B Switch configuration (conceptual) 20
c. RF and data patch panel configurations (conceptual) 21
d. I/O panel configurations (conceptual) 22
CONTROL ROOM RACK CONFIGURATION
RACK 3 RACK 2 RACK 1
BLANK Power Strip (RAPTOR) Power Strip (RAPTOR)
BLANK
PELCO DVR (DX4700/4800)
Cell Phone Modem (Raven)
BLANK CAMERA SWITCHE
BLANK External Antenna Patch Panel Naked Patch Panel
BLANK Naked Switch
BLANK Blue Ray/DVD player SBU Patch Panel
BLANK
Digital OTA Tuner///OTA antenna cont. SBU Switch
BLANK TV A/B switches SBU Router
BLANK Sat TV receiver #1 BLANK
BLANK Sat TV receiver #2 Accessory Patch Panel BLANK Sat TV controler BLANK BLANK Power Strip (RAPTOR) Data Encryption (TacLan)
BLANK ICPC///Volume control FBI Router
BLANK Crosspoint 1600 FBI Switch
BLANK FBI Patch Panel
BLANK BLANK
BLANK
DRAWER
BLANK
BLANK UPS
BLANK BLANK
BLANK
UPS
DRAWER
BLANK
BLANK
Motorola
BLANK
BLANK
BLANK (7 AC) BLANK
WORK DESK
STORAGE FOR COMPUTERs & VOIPs
A/B SWT
CROSSPOINT 1600
EXTRON SWITCHER
POWER SPLITTER POWER SPLITTER
A/B SWT A/B SWT
EXT
INPUT
PANEL
OVER THE AIR
WORK AREA
FRONT
TELEVISION
WORK AREA
MIDDLE
TELEVISION
WORK AREA
REAR
TELEVISION
A/B SWT
OVER THE AIR
DIGITAL
TUNER
A/B SWT
Concept of rack mounted RF patch panel
Concept of rack mounted data patch panel
Concept of exterior I/O panels
LMR
RG
FROM I/O
PANEL
LMR 240 ISR
ANT
FROM
MAST
TO
ROUTER
CONSOLES
TO
SWITCH
CONSOLE
S
RA
VE
N
FROM
I/O
PANEL
FRO
M
MAS
T
R F
R F
R F
DA
TA
#1
DA
TA
#2
PASS-
THRU
GREEN
NETWOR
K
RED
NETWOR
K
WHITE
NETWOR
K
TO RACK RF
PATCH PANEL
TO TV
ANTENNA
POWER
SPLITTER
TO RACK RF
PATCH PANEL
LMR
LMR
LMR 240
RG
-6
RG-6
EXTERIOR I/O PANELS
TO RACK DATA
PATCH PANEL
RG-6
| General Scope of Work |
| 1. SUMMARY OF WIRING SPECIFICATIONS AND EQUIPMENT INSTALLATION |
| 2. LABELING |
| a. Panels |
| b. Cables/Wiring |
| Detailed Scope of Work |
| 1. EXTERNAL CABLING |
| a. Mast |
| b. Roof |
| c. Exterior I/O panels |
| 2. CONTROL ROOM |
| a. Rack cable management |
| b. Remove all non-essential cabling |
| c. Replace/re-run all necessary cabling |
| ii. Install and wire Over the Air (OTA) digital tuner and antenna controller |
| iii. Install and wire EXTRON XTP Crosspoint 1600 system (GFE) |
| iv. Supply, install and wire satellite TV antenna controller |
| v. Install and wire satellite TV receiver boxes X 2 (GFE) |
| vi. Install and wire rack mounted AM/FM/CD player (GFE) |
| vii. Install and wire rack mounted Blue Ray player (GFE) |
| viii. Install and wire rack mounted speakers (GFE) |
| x. Supply, install and wire Video Monitor A/B Switches |
| xi. Install and wire Pelco video DVR DX4700/4800 (GFE) |
| xii. Install and wire 24 port Cisco data switches x 3 (GFE) |
| xiii. Configure rack space for the following GFE per attached rack diagram: |
| a. |
| b. |
| c. |
| d. |
| e. |
| f. |
| g. |
| h. |
| i. |
| f. Fabricate, install and wire rack mounted RF patch panel |
| 1. |
| g. Fabricate, install and wire rack mounted data patch panel (GFE) |
| h. AC electrical distribution for equipment racks |
| 3. WORK AREA. Remove all non-essential cabling and replace as listed below |
| a. AC electrical wiring |
| b. Computer/Extron Patching Station |
| e. Video Monitors |
| i. Driver’s side 48” x 3 |
| ii. Rear wall (control room) 32” |
| f. Audio System |
| i. House Speakers (GFE) |
| 1. Kramer Galil 4-C speakers x 4 |
| 4. ADDITIONAL MODIFICATIONS |
| a. Control Room |
| b. Work Area |
| i. Design, fabricate and install shelving system at rear most end of driver’s side work table (size and final location to be approved by customer). |
| c. Exterior |
| i. Video monitor 48” |
| ii. Roof coating |
| 1. Thermal/UV load resistant coating |
| iv. Rear flood lights |
| 1. Supply and install LED Flood lights |
| 2. Dual switched to turn on when: |
| a. Vehicle transmission is shifted into reverse |
| 3. Comparable to WHELEN 600 series (24 diode) |
| 4. X 2 Mounted high on truck |
| 5. PROJECT LOGISTICS AND ACCEPTANCE |
| 6. WARRANTY |
| 7. DOCUMENTATION |
| 8. ATTACHMENTS |