RFQ Atch 5 SOW-Appendix C1.pdf
PDF 531 KB Posted
- Attached to
- RAN Clear Zone South Demo Federal contract opportunity
- Solicitation number
- FA3016-21-U-0095
About this file
This document contains a limited pre-demolition asbestos survey report and related federal contract opportunity solicitation. The asbestos survey report documents the inspection of interior and exterior finish materials at 10712 Lower Seguin Road in Schertz, Texas. Eighteen samples were collected from homogeneous areas and analyzed, with no asbestos detected. The related federal contract opportunity is solicitation number FA3016-21-U-0095 for hazardous material abatement, demolition and removal services of multiple properties within the clear zone of runways at Joint Base San Antonio-Randolph. The work includes one rural tract with structures, two undeveloped parcels with debris, and cleanup to return the properties to a natural vegetated state. Offerors should review the RFQ and associated appendices for property listings, surveys, environmental assessments and hazardous material surveys.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RAN Clear Zone South Demo RFQ - Amendment 0002.pdf | ||
| RFQ Atch 1 RAN Clear Zone South Demo SOW 20 May 2021.pdf | ||
| RFQ Atch 11 - Questions and Answers.pdf | ||
| RAN Clear Zone South Demo RFQ - Amendment 0001.pdf | ||
| RFQ Atch 4 SOW-Appendix B2.pdf | ||
| RFQ Atch 6 SOW-Appendix C2.pdf | ||
| RFQ Atch 9 SOW-Appendix D2.doc | DOC document | |
| RAN Clear Zone South Demo RFQ.pdf | ||
| RFQ Atch 1 RAN Clear Zone South Demo SOW.pdf | ||
| RFQ Atch 2 SOW-Appendix A.pdf | ||
| RFQ Atch 7 SOW-Appendix C3.pdf | ||
| RFQ Atch 8 SOW-Appendix D1.doc | DOC document | |
| RFQ Atch 3 SOW-Appendix B1.pdf | ||
| RFQ Atch 10 WD - 2015-5253 - Rev 12.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
August 2, 2017 Project No: 1707255ARG
Doug McGookey, P.G.
Vice President/Geologist Phone: (210) 694-4545 Medina Consulting Company, Inc.
6391 De Zavala, Ste. 106 San Antonio, Texas 78249
RE: LIMITED PRE-DEMOLITION ASBESTOS SURVEY REPORT – 10712 LOWER
SEGUIN ROAD, SCHERTZ, TEXAS
Dear Mr. McGookey:
Argus Environmental Consultants, LLC (Argus) performed a limited pre-demolition asbestos survey of the interior and exterior finish materials associated with the single-family residential property structure located at 10712 Lower Seguin Road in Schertz, Texas.
The Scope of Services included in the limited asbestos survey consisted of the following:
Visual evaluation of the interior and exterior finish materials associated with the property’s structure at the time of the survey Identification of suspect asbestos containing materials (ACM) into homogeneous areas based upon the guidelines in the United States Environmental Protection Agency’s (EPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E
Random, non-destructive collection of bulk samples from building materials that potentially contain asbestos
Laboratory analysis of building material samples by a third party laboratory licensed by the Texas Department of State Health Services (DSHS)
Analysis by Polarized Light Microscopy (PLM) using EPA Method 600
Argus’ entire liability pertaining to this report and all work associated with it is limited to the invoiced amount defined within the Scope of Services.
The asbestos survey was performed on July 26, 2017 by Elizabeth Aguilar, Texas DSHS Asbestos Inspector License #603203.
Bulk Samples:
Eighteen samples were collected from the following homogenous areas identified as potential
ACM:
Homogenous Area
Description
Sample IDs
1 Gypsum Board H1ABC 2 Ceiling Texture H2ABC 3 Off-White Rolled Flooring and Yellow Mastic H3ABC 4 Yellow Ceramic Tile Mastic H4ABC 5 White Ceramic Tile Caulk H5ABC 6 Carpet, Yellow Mastic H6ABC
Conclusions:
Within the eighteen bulk samples collected, twenty-one separate construction material layers were subjected to PLM laboratory analysis. Asbestos was not identified in any sample.
Recommendations:
Inform contractors involved with any demolition related activities that no ACM was identified.
Due to the limited nature of this survey, Argus does not verify the existence or non-existence of ACM in areas not sampled. For example, invasive destructive sampling, evaluation in any inaccessible areas, or any areas of the building outside the proposed evaluation has not been done.
Therefore, any suspect materials hidden in or behind walls, under the flooring or other inaccessible areas are not included in this report. Argus only warrants the existence or non-existence of asbestos in those materials actually sampled.
For Argus Environmental Consultants, LLC, Elizabeth Aguilar Texas DSHS Asbestos Inspector License #603203 (Exp. 12/12/2018)
Mark D. Freemyer, CIEC Texas DSHS Asbestos Consultant License #105695 (Exp. 6/12/2018)
Attachments: 1) EMSL Analytical, Inc.’s EPA 600 PLM Test Report dated 8/1/2017
2) Bulk Sample Diagram
Pre-Demolition Asbestos Survey Report
10712 Lower Seguin Road, Schertz, Texas
OrderID: 161713732
OrderID: 161713732
EMSL Analytical, Inc.
6340 CastlePlace Dr. Indianapolis, IN 46250
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
161713732EMSL Order:
Customer ID: ARGU52
Customer PO:
Project ID:
Attention: Phone:Sarah Akeroyd (210) 493-2560
Fax:Argus Environmental (210) 342-9027
Received Date:10004 Wurzbach Road 07/27/2017 10:20 AM
Analysis Date:Suite 247 08/01/2017
Collected Date:San Antonio, TX 78230-2214 07/26/2017
Project: 1707255ARG / Medina (Engelke)
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
H1A
161713732-0001
None DetectedGypsum
Non-fibrous (Other)
80%
5%
Cellulose15%Brown/White
Fibrous
Heterogeneous
Ceiling System - Hall
- Gypsum Board -
White
H1B
161713732-0002
None DetectedGypsum
Non-fibrous (Other)
90%
5%
Cellulose5%White
Non-Fibrous
Homogeneous
Ceiling System -
Kitchen - Gypsum
Board - White
H1C
161713732-0003
None DetectedGypsum
Non-fibrous (Other)
90%
5%
Cellulose5%White
Non-Fibrous
Homogeneous
Ceiling System -
Storage 1 - Gypsum
Board - White
H2A
161713732-0004
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceiling System -
Popcorn - Hall -
Texture - White
Inseparable paint / coating layer included in analysis
H2B
161713732-0005
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceiling System -
Popcorn - Kitch -
Texture - White
Inseparable paint / coating layer included in analysis
H2C
161713732-0006
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceiling System -
Popcorn - Storage 1 -
Texture - White
H3A-Flooring
161713732-0007
None DetectedNon-fibrous (Other)100%Black/Beige
Non-Fibrous
Homogeneous
Flooring - Hall -
Rolled Flooring and
Mastic - Off-White and Yellow
H3A-Mastic
161713732-0007A
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
Flooring - Hall -
Rolled Flooring and
Mastic - Off-White and Yellow
H3B-Flooring
161713732-0008
None DetectedNon-fibrous (Other)100%Black/Beige
Non-Fibrous
Homogeneous
Flooring - Living
Room - Rolled
Flooring and Mastic -
Off-White and Yellow
H3B-Mastic
161713732-0008A
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
Flooring - Living
Room - Rolled
Flooring and Mastic -
Off-White and Yellow
H3C-Flooring
161713732-0009
None DetectedNon-fibrous (Other)100%Black/Beige
Non-Fibrous
Homogeneous
Flooring - Workroom -
Rolled Flooring and
Mastic - Off-White and Yellow
H3C-Mastic
161713732-0009A
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous
Flooring - Workroom -
Rolled Flooring and
Mastic - Off-White and Yellow
H4A
161713732-0010
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 1 - Mastic -
Yellow
Initial report from: 08/01/2017 15:22:25
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 8/1/2017 3:22 PM
EMSL Analytical, Inc.
6340 CastlePlace Dr. Indianapolis, IN 46250
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
161713732EMSL Order:
Customer ID: ARGU52
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
H4B
161713732-0011
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 1 - Mastic -
Yellow
H4C
161713732-0012
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 2 - Mastic -
Yellow
H5A
161713732-0013
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 1 - Caulk -
White
H5B
161713732-0014
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 1 - Caulk -
White
H5C
161713732-0015
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Ceramic Tile -
Bathroom 2 - Caulk -
White
H6A
161713732-0016
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Carpet - Office -
Mastic - Yellow
H6B
161713732-0017
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Carpet - Storage 1 -
Mastic - Yellow
H6C
161713732-0018
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Carpet - Storage 1 -
Mastic - Yellow
Analyst(s)
Jadda Moffett (7)
Ross Matlock (14)
Richard Harding, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN NVLAP Lab Code 200188-0, AZ0939, CA 2575, CO AL-15132, TX 300262
Initial report from: 08/01/2017 15:22:25
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 8/1/2017 3:22 PM
Bedroom 1 Bedroom 2
Office
Bathroom 1 Bathroom 2
Shower
Closet Closet
C l o s e t
Washer
Entry
Storage 1
Living Room
Kitchen Workroom Storage 2
H1A H2A H3A
H1B H2B
H1C H2C
H6BC
H3B
H3C
H4AB
H5AB
H4C H5C
H6A
Hall
Pre-Demolition Asbestos Survey Bulk Sample Diagram 10712 Lower Seguin Road, Schertz, Texas
Legend
Green - Non-Asbestos Sample Locations
Date: 7/26/17
10004 Wurzbach Road, Ste. 247 San Antonio, Texas 78230
Consultants, LLCEnvironmental
| Pre-Demolition ACM Survey Report - 10712 Lower Seguin Road |
| Asbestos COC |
| Asbestos Results |
| Bulk Sample Diagram - 10712 Lower Seguin Rd |
File details come from the government source that posted it. Updated .