RFB938100-01 - ISD Elem. & Outreach Fire - Addendum 03.pdf

PDF 5 MB Posted

Attached to
ISD Elem. School & Outreach Bid. Fire Alarm Replacement
Solicitation number
RFB938100-01
Issued by
Pottawattamie County, Iowa

About this file

This document is an addendum to a Request for Bids (RFB) issued by the Iowa Department of Administrative Services for the demolition and replacement of the fire alarm systems at the Outreach Building and Elementary Building of the Iowa School for the Deaf located in Council Bluffs, Iowa. The addendum revises the bid due date to 10:00 am on March 7, 2024 and provides clarification on hazardous materials surveys and coordination requirements for the fire alarm contractor. The project also requires a 5% bid security and will be awarded through the IMPACS Electronic Procurement System.

The addendum discloses the presence of lead-containing paint and asbestos-containing materials in the buildings that may impact the fire alarm system installation. The fire alarm contractor will need to coordinate the layout of system components with the construction manager and the state's hazardous materials abatement contractor to minimize disruptions. The hazardous materials abatement will be performed by the owner, the State of Iowa.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ISD Elem. School & Outreach Bld. Fire Alarm Replacement Council Bluffs, IA

DAS 9381.00

RFB938100-01

Addendum #3

ADDENDUM #3

Project Name:

DAS# 9381.00

RFB 938100-01

Dated: March 04, 2024

This Addendum forms a part of the bidding and contract documents. This Addendum supersedes and supplements all portions of the original bidding and contract documents dated Feb. 02, 2024 with which it conflicts.

ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN THE SPACE PROVIDED ON THE

BID FORM. FAILURE TO DO SO MAY SUBJECT THE BIDDER TO

DISQUALIFICATION.

1) CLARIFICATIONS

A. BIDS DUE DATE REVISED: Bids must be received no later than 10:00 am, Thursday, March 7, 2024. Late bids will not be considered. Bids shall be submitted on IMPACS Electronic Procurement System. The Bid shall be accompanied by a Bid Security as set forth in the Instructions to Bidders in the amount of 5% of the total bid amount. Each bid shall be accompanied by a bid bond, cashier’s check or a certified check drawn upon a solvent bank chartered under the laws of the United States of America.

B. Hazardous materials reports are provided for reference and are attached to this addendum. Hazardous materials abatement is by owner (State of Iowa).

C. Lead containing paint and lead based paint have been identified in the Outreach

Building that may impact the construction of the fire alarm system components. The fire alarm contractor shall coordinate layout of devices, conduits, penetrations, pathways, and misc. fire alarm components with the construction manager and the

States abatement contractor for removal of lead containing paint and lead based paint that would affect such items.

D. Asbestos containing material has been identified in the Elementary Building that may impact the construction of the fire alarm system components. The fire alarm contractor shall coordinate layout of devices, conduits, penetrations, pathways, and misc. fire alarm components with the construction manager and the States abatement contractor for removal of asbestos containing material that would affect such items.

E. The fire alarm contractor shall coordinate layout of devices, conduits, penetrations, pathways, and misc. fire alarm components with the construction manager. The intent is to coordinate the layout of the fire alarm system to reduce the hazardous materials contractor to four site visits.

https://bids.sciquest.com/apps/Router/PublicEvent?CustomerOrg=DASIowa

Council Bluffs, IA

DAS 9381.00

RFB938100-01

2) PLANS

A. No Items

3) QUESTIONS AND CLARIFICATIONS

A. No items.

4) SUBSTITUTION REQUESTS

A. No items.

5) ATTACHMENTS

A. Revised Notice to Bidders

B. Hazardous Building. Materials Survey Report, ISD Outreach Bld. – Fire Alarm

Replacement Project, Atlas Proj. ID : 204BS06748 (27 pages)

C. Hazardous Building. Materials Survey Report, Elementary School Bld. – Fire Alarm

Replacement Project, Atlas Proj. ID : 204BS06743 (30 pages)

END OF ADDENDUM

4503 East 50th Street, Suite 800, Des Moines, Iowa 50317

515.981.4528 | oneatlas.com

HAZARDOUS BUILDING MATERIALS SURVEY

REPORT

PREPARED FOR:

Samuels Group 2929 Westown Parkway, Suite 200

Des Moines, Iowa 50266

PROJECT LOCATION:

Iowa School for the Deaf – Outreach Building Fire Alarm Replacement Project 3501 Harry Langdon Boulevard

Council Bluffs, Iowa

Project Date: January 26, 2024

Report Date: February 6, 2024

Atlas Project ID: 204BS06748

PREPARED BY:

Atlas Technical Consultants 4503 E 50th Street, Suite 800

Des Moines, IA 50317 i

February 6, 2024

Mr. Jerry Dehnke 2929 Westown Parkway, Suite 200 Des Moines, Iowa 50266

Re: Hazardous Building Materials Survey Report

Iowa School for the Deaf – Outreach Building Fire Alarm Replacement Project

Atlas Project Number: 204BS06748

Atlas is pleased to submit the attached Hazardous Building Materials Survey Report for the above-referenced site. The survey was limited to surfaces and materials that would be impacted by planned fire alarm replacement activities. This report includes procedures, methodologies and analytical laboratory results.

Atlas appreciates the opportunity to perform these services for the IDAS and the Samuels Group, and we look forward to working with you in the future. If you need any assistance with the implementation of the recommendations contained in this report, please feel free to give us a call at (402)670-3842 and we will respond promptly to your needs.

Sincerely, ATLAS TECHNICAL CONSULTANTS, LLC

Chase Bucknell Steve Hudson, MS, CIH Iowa Inspector Senior Project Manager

(402) 697-9747 (402) 670-3842

T A B L E O F C O N T E N T S

LETTER OF TRANSMITTAL ...................................................................................... i

1.0 SCOPE OF SERVICES

2.0 GENERAL SITE CONDITIONS

3.0 ASBESTOS SURVEY REPORT

3.1 Regulation Review

3.2 Homogeneous Areas

3.3 Sampling Strategy

3.4 Suspect Asbestos-Containing Materials

3.5 Laboratory Analytical Results

4.0 LEAD PAINT SURVEY

4.1 Inspection

4.2 Lead Paint Testing

5.0 HAZARDOUS MATERIALS ASSESSMENT

6.0 CONCLUSIONS

7.0 ASSUMPTIONS AND LIMITATIONS

APPENDICES

APPENDIX A ASBESTOS TEST RESULTS

APPENDIX B LEAD PAINT TEST RESULTS

APPENDIX C SAMPLE LOCATION SKETCH

APPENDIX D INSPECTOR ACCREDITATIONS

Hazardous Building Materials Survey Report outreach Building Council Bluffs, Iowa

February 6, 2024 Project No. 204BS06748

H A Z A R D O U S B U I L D I N G M A T E R I A L S

S U R V E Y R E P O R T

Iowa School for the Deaf – Outreach Building Fire Alarm Replacement Project 3501 Harry Langdon Boulevard

Atlas Project Number: 204BS06748

1.0 SCOPE OF SERVICES

The purpose of this project was to perform a survey for hazardous building materials that may be impacted by planned fire alarm replacement activities at the above-referenced property.

Atlas provided a representative hazardous materials survey in accordance with the referenced agreement and as outlined below:

1. Review any existing hazardous building material survey reports relating to the site, if available.

2. Identify suspect asbestos-containing materials (ACM), surface coatings potentially containing lead paint, and hazardous building materials within the planned work areas.

3. Collect and analyze bulk samples of suspect asbestos containing materials and collect paint chip samples from representative surface coatings potentially containing lead-based or lead-containing paint.

4. Provide laboratory analysis of collected samples.

5. Provide a report of findings with copies and interpretation of analytical results and identifying the locations of asbestos-containing materials, lead paint, and hazardous building materials.

2.0 GENERAL SITE CONDITIONS

The survey was conducted at the Outreach Building located at the Iowa School for the Deaf in Council Bluffs, Iowa. The survey area was limited to the areas to be disturbed as part of planned fire alarm replacement activities.

3.0 ASBESTOS SURVEY

On January 26, 2024, areas expected to be impacted by planned renovation activities were inspected for asbestos-containing building materials by inspector Jazhan Amill of Atlas. Mr. Amill has completed the requisite training for asbestos accreditation as inspector at a state approved training provider under TSCA Title II. Mr. Amil’s State of Iowa Inspector number is #22-8633.

The planned renovation work areas were visually inspected for the presence of suspect asbestos-containing materials (ACM). Materials that were hidden, not accessible, or when sampled would damage the integrity of the structure, were not sampled as part of this survey. Materials visibly identified as non-asbestos (fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos survey consisted of three basic steps: 1) a visual inspection of the proposed work areas; 2) a determination of homogeneous areas with suspect surfacing, thermal system insulation, and miscellaneous materials; and 3) sampling accessible, friable and non-friable, suspect materials.

3.1 Regulation Review

The U.S. EPA qualifies asbestos-containing materials (ACM) as materials with an asbestos content greater than 1%. The following definitions are taken from Section

61.141 of Subpart M, Part 61 of Title 40: Protection of Environment of the Code of Federal Regulations (CFR).

• “Category I non-friable asbestos-containing material (ACM)” is defined as asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1% asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy (PLM).

• “Category II non-friable ACM” is defined as any material, excluding Category I non-friable ACM, containing more than 1% asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

• “Friable asbestos material” is defined as any material containing more than 1% asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, PLM that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. If the asbestos content is less than 10% as determined by a method other than point counting by PLM, verify the asbestos content by point counting using

PLM.

3.2 Homogeneous Areas

Prior to sampling, homogeneous areas were identified in order to facilitate a sampling strategy. A homogeneous sampling area can be described as one or more areas with suspect material similar in appearance and texture that have the same installation date and function. The actual number of samples collected from each homogeneous sampling area may vary, dependent upon material type and the professional judgment of the inspector.

3.3 Sampling Strategy

The sampling strategy incorporated AHERA requirements, quantities of suspect material, and the inspector’s judgment to aid in the identification of suspect asbestos-containing materials. If the analytical results indicated that all the samples collected per homogeneous area did not contain asbestos, then the homogeneous area (material) was considered non-asbestos-containing. However, if the analytical results of one or more of the samples collected per homogeneous area indicated that asbestos was present in quantities greater than one percent asbestos (as defined by EPA), all of the homogeneous area (material) was treated as an asbestos-containing material regardless of any other analytical results. Materials which were visually determined to be non-asbestos (i.e. fibrous glass, foam rubber, etc.) by the accredited inspector were not required to be sampled. Actual collection of a bulk asbestos sample involves physically removing approximately one square inch (1 in2) of material and placing it in an airtight sample container. Sample containers were marked with a unique identification number, which was documented in the field notes.

3.4 Suspect Asbestos-Containing Materials

The following table contains a list of the eighteen (18) identified suspect asbestos containing materials sampled:

T A B L E 1 : S U S P E C T A S B E S T O S M A T E R I A L S

MATERIAL LOCATION SAMPLE NUMBER

2x2 White Small Fissured Ceiling Tile Floor 1 - North Entrance & Lobby 1-3

Plaster Ceilings Floor 1 - North Entrance, Restroom Hall & Storage Room 4-6

Drywall / Joint Compound on Walls

Floor 1 – North Entrance, South

Restroom Hall

Floor 2 – North Office

7-12

2x4 White Pinhole / Fissure Ceiling Tile Floor 2 – Storage Room, Room

13-15

2x4 White Pinhole / Ridges Ceiling Tile Floor 2 – North Office 16

Brown Wall Mastic Floor 2 – North Office 17

2x4 White Pinhole Ceiling Tile Floor 2 – South Office 18

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

T A B L E 2 : A S B E S T O S - C O N T A I N I N G M A T E R I A L S

MATERIAL LOCATION

SAMPLE

NUMBER

APPROX.

QUANTITY

ASBESTOS

CONTENT

No Asbestos Containing Materials were Identified

3.5 Laboratory Analytical Results

Bulk samples were analyzed by EMSL Analytical, Inc. located at 200 Route 130 North, Cinnaminson, NJ. Polarized Light Microscope analysis, utilizing dispersion staining techniques (ref.: EPA Method 600/M4-82-020), was performed to determine the asbestos content of the bulk samples collected at the site. This laboratory is currently a proficient participant in the American Industrial Hygiene Association (AIHA) Bulk Asbestos Proficiency Analytical Testing Program; a quality assurance program for polarized light microscopy analysis. Any material that contains greater than one percent asbestos is considered an ACM and must be handled according to Occupational Safety and Health Administration (OSHA), EPA, and all applicable state and local regulations.

Laboratory test results are provided in Appendix A.

4.0 LEAD PAINT SURVEY

On January 26, 2024, the Iowa School for the Deaf was inspected for lead paint by Mr. Steve Hudson and Mr. Jazhan Amill of Atlas. The purpose of the survey was to identify locations and concentrations of lead in paints and coatings on interior building components that may be disturbed as part of planned fire alarm replacement activities.

4.1 Inspection

The lead survey was performed in general accordance with the U.S. Housing and Urban Development Chapter 7 of the Guidelines for the evaluation and Control of Lead-Based Paint Hazards in Housing (1997 Revision). Survey criteria included the inspection and sampling of the representative painted surfaces on the interior of the building.

Regulatory limits from the Housing and Urban Development (HUD) and the Environmental Protection Agency (EPA) establishes that lead-based paint (LBP) by definition is paint that contains more than 0.5% of lead in paint. OSHA’s “Lead in Construction Standard” (29 CFR 1926.1101) addresses any concentration of lead in paint (“lead-containing paint”).

Prior to demolition or renovation activities, all contractors involved should be notified regarding the presence of painted components under the guidelines of the OSHA Lead in Construction standard 29 CFR 1926.62. Care should be exercised in acknowledging that the OSHA 29 CFR 1926.62 has no LBP threshold definition and is concerned with exposures generated by LBP disturbances, which may include materials containing less than 0.5% lead by weight. The OSHA regulations are based strictly on airborne lead concentrations; therefore, the measured lead concentration of the paint and the method of paint disturbance will both factor into the potential airborne hazard.

OSHA requires the contractor to inform its employees of potential lead hazards, based upon the work being performed. The purpose of OSHA’s Lead Construction Standard is to reduce the exposure to lead for all construction workers. It is for this reason that Atlas recommends contractors be informed of the presence of lead.

OSHA’s standard includes an 8-hour time weighted average (TWA) of 50 micrograms of lead per cubic meter of air (mg/m3) and an action level (regardless of respirator use) of 30 mg/m3.

Prior to disposal of debris that contains materials that have been found to contain lead, conduct a Toxicity Characteristic Leaching Procedures (TCLP) on representative solid wastes. This will determine if the debris requires a hazardous waste disposal site. A TCLP was not collected as part of this current inspection.

4.2 Lead Paint Testing

A total of eight (8) surface coatings were tested to determine the concentration of lead. The sampling generally involved the collection of the paint on the surface down to the substrate over an area of approximately 2 to 3 square inches. A summary of the tested paints is provided in the table below. In order for a surface coating to be considered a lead-based paint, the paint must contain lead in concentrations greater than 0.5% by weight. A detectable concentration of lead in the surface coating below 0.5% by weight is considered a lead-containing paint.

The full copy of the lead analytical results is included in Appendix A.

Lead Paint Sampling Summary

Sample

ID

Sample Location

Representative Material

Paint Color

Lead Content %

P-1 Basement – Ceiling Concrete White <0.015

P-2 Basement – Walls & Columns

Concrete Yellow <0.017

P-3 1st Floor – Ceiling North Entrance

Plaster White 0.054

• Lead-based paint was not identified in any of the surface coatings tested.

• Lead-containing paint was identified in 4 of the 8 surface coatings tested.

This evaluation report can help the Owner develop a plan for renovating the building by having concentrations of lead in the paint identified. It is our understanding that the information in this report will be provided to the contractors so that appropriate precautions can be made to minimize worker exposure to lead.

If surface coatings with lead containing paint are handled improperly, exposure could occur to workers and future occupants of the facility.

5.0 HAZARDOUS MATERIALS ASSESSMENT

Atlas completed a visual inspection of rooms / areas throughout the intended work areas to identify hazardous wastes or universal wastes that may be impacted by planned renovation activities. The survey included a visual inspection of: light fixtures and other equipment for the presence of Polychlorinated Biphenyls (PCBs); light bulbs, thermostats, switches, and other equipment for the presence of mercury; refrigerants, batteries, and devices with potential radioactive materials.

TABLE 3: HAZARDOUS BUILDING MATERIALS

Category Material Estimated Quantity

Poly-Chlorinated Biphenyl

(PCBs)

Transformers N/A

Transistors N/A

Light Ballasts N/A

Mercury

Thermostats N/A

Switches/Relays N/A

Fluorescent Light Tubes N/A

High Intensity Discharge lights N/A

Lead Paint Sampling Summary

Sample

ID

Sample Location

Representative Material

Paint Color

Lead Content %

P-4 1st Floor – Wall - South Restroom Hall

Plaster White 0.16

P-5 1st Floor- Wall - South Restroom Hall

Drywall Blue <0.014

P-6 2nd Floor – Wall - North Office Area

Drywall Grey 0.075

P-7 2nd Floor – Wall – North Office Area

Plaster Aqua 0.10

P-8 2nd Floor – Wall – South Office Area

Drywall Grey <0.015

Category Material Estimated Quantity

Thermometers/ Manometers N/A

Batteries

Smoke Detectors 58

Emergency Lighting Systems N/A

Exit Signs 10

Flashing Fire Alarms 12

Chlorofluorocarbons

(CFCs) or

Hydro

Chlorofluorocarbons

(HCFCs)

Refrigerators/Freezers/Chillers N/A

Low Level Radioactive

Sources (LLR) Smoke/Fire Alarms N/A

Hazardous materials or universal wastes identified in Table 1 shall be removed as part of the renovation contractor’s scope of work and disposed of according to US EPA Toxic Substances Control Act (TSCA) and the State of Iowa regulations.

6.0 CONCLUSIONS

The following conclusions are summarized as follows:

• No asbestos containing materials were identified.

• Lead-based paint was not identified in the surface coatings tested.

• Lead-containing paint was identified in 4 of the 8 surface coatings tested.

7.0 ASSUMPTIONS AND LIMITATIONS

The results, findings, conclusions, and recommendations expressed in this report are based solely on conditions noted during the January 26, 2024, Atlas hazardous building materials survey of the Outreach Building located at the Iowa School for the Deaf in Council Bluffs, Iowa.

Atlas did not perform destructive sampling -- it was not within Atlas’s scope of work to remove surface materials to investigate portions of the structure or materials that may lay beneath the surface -- thus, any materials that could not be visually identified on the surface were not inspected and would not be noted in this report.

Atlas’s selection of sample locations and frequency of sampling was based on the inspector’s assumption that like materials in the same area are homogeneous in content.

The report is designed to aid the building owner, architect, construction manager, general contractor, and potential abatement contractor in locating hazardous building materials. Under no circumstances is the report to be utilized as a bidding document or as a project specification document since it does not have all the components required to serve as a Project Design document or an Abatement Work plan.

Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated.

This report is intended for the sole use of the IDAS and Samuels Group. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user.

APPENDIX A

ASBESTOS TEST RESULTS

EMSL Analytical, Inc.

200 Route 130 North Cinnaminson, NJ 08077

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042401855EMSL Order:

Customer ID: ATC55

Customer PO:

Project ID:

Attention: Phone:Steve Hudson (402) 697-9747

Fax:Atlas Technical (402) 597-8532

Received Date:11117 Mockingbird Drive 01/29/2024 11:00 AM

Analysis Date:Omaha, NE 68137 01/31/2024

Collected Date: 01/26/2024

Project: 204BS06748 / Iowa DAS / Asbestos Testing / Outreach Building

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

042401855-0001

None DetectedNon-fibrous (Other)40%Cellulose

Min. Wool

40%

20%

Tan

Fibrous

Homogeneous

Floor 1 - North

Entrance - 2'x2' White

Small Fissured

Ceiling Tile

042401855-0002

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

50%

30%

Tan

Fibrous

Homogeneous

Floor 1 - North

Entrance Hall - 2'x2'

White Small Fissured

Ceiling Tile

042401855-0003

None DetectedNon-fibrous (Other)35%Cellulose

Min. Wool

55%

10%

Gray/White

Fibrous

Homogeneous

Floor 1 - Lobby - 2'x2'

White Small Fissured

Ceiling Tile

4-Plaster

042401855-0004

None DetectedNon-fibrous (Other)100%Gray/Tan

Non-Fibrous

Homogeneous

Floor 1 - North

Entrance - Plaster

Ceiling

4-Skim Coat

042401855-0004A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 1 - North

Entrance - Plaster

Ceiling

5-Plaster

042401855-0005

None DetectedNon-fibrous (Other)100%Gray/White

Non-Fibrous

Homogeneous

Floor 1 - North

Restroom Hall -

Plaster Ceiling

5-Skim Coat

042401855-0005A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 1 - North

Restroom Hall -

Plaster Ceiling

6-Plaster

042401855-0006

None DetectedNon-fibrous (Other)98%Cellulose2%Gray

Fibrous

Homogeneous

Floor 2 - Storage

Rom - Plaster Ceiling

6-Skim Coat

042401855-0006A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 2 - Storage

Rom - Plaster Ceiling

042401855-0007

None DetectedNon-fibrous (Other)80%Cellulose20%Brown/White

Fibrous

Homogeneous

Floor 1 - North

Entrance - Drywall

042401855-0008

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 1 - North

Entrance - Joint

Compound

042401855-0009

None DetectedNon-fibrous (Other)80%Cellulose20%Brown/White

Fibrous

Homogeneous

Floor 1 - South

Resrtoom Hall -

Drywall

042401855-0010

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 1 - South

Resrtoom Hall - Joint

Compound

042401855-0011

None DetectedNon-fibrous (Other)85%Cellulose15%Brown/White

Fibrous

Homogeneous

Floor 2 - North Office

- Drywall

12-Joint Compound

042401855-0012

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 2 - North Office

- Joint Compound

Initial report from: 02/01/2024 07:43:09

Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 2/1/2024 7:43 AM

Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com

042401855EMSL Order:

Customer ID: ATC55

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E

Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

12-Joint Compound 2

042401855-0012A

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Floor 2 - North Office

- Joint Compound

042401855-0013

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

50%

30%

Tan

Fibrous

Homogeneous

Floor 2 - Storage

Room - 2'x4' White

Pinhole/Fissure

Ceiling Tile

042401855-0014

None DetectedNon-fibrous (Other)25%Cellulose

Min. Wool

55%

20%

Tan

Non-Fibrous

Homogeneous

Floor 2 - Storage

Room - 2'x4' White

Pinhole/Fissure

Ceiling Tile

042401855-0015

None DetectedNon-fibrous (Other)25%Cellulose

Min. Wool

45%

30%

Gray/White

Fibrous

Homogeneous

Floor 2 - Rm 211 -

2'x4' White

Pinhole/Fissure

Ceiling Tile

042401855-0016

None DetectedNon-fibrous (Other)40%Cellulose

Min. Wool

40%

20%

Tan

Fibrous

Homogeneous

Floor 2 - North Office

Area - 2'x4' White

Pinhole/Ridges

Ceiling Tile

042401855-0017

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Floor 2 - North Office

Area - Brown Wall

Mastic behind Drywall

042401855-0018

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

45%

35%

Tan/White

Fibrous

Homogeneous

Floor 2 - South Office

Area - 2'x4' White

Pinhole Ceiling Tile

Analyst(s)

Alex Francois (12)

Megan Bosch (10)

Samantha Rundstrom, Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NVLAP Lab Code 101048-0, AIHA LAP, LLC-IHLAP Lab 100194, PA ID# 68-00367, LA #04127

Initial report from: 02/01/2024 07:43:09

Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 2/1/2024 7:43 AM

OrderID: 042401855

APPENDIX B

LEAD PAINT TEST RESULTS

Customer PO:

EMSL Sales Rep:

Reported:

Atlas Technical [ATC55]

11117 Mockingbird Drive

Omaha, NE 68137

EMSL Analytical, Inc.

200 Route 130, Cinnaminson, NJ, 08077

Telephone: 856-858-4800 Fax:856-786-5974

EMSL-CIN-01

Allison NicholsAttention:

(402) 697-9747

Allison.Williams@oneatlas.com Received: 01/29/2024 09:00

01/30/2024 18:16

Anthony DeRosa

EMSL Order ID: 012406654

LIMS Reference ID: AC06654

EMSL Customer ID: ATC55

204BS06748

Analytical Results

Analyte Results RL Q DF

Analysis Date

& AnalystWeight(g)

Prep Date

& Tech

Analytical

MethodPrep Method

Client Sample ID: P-1/White Concrete Basement Ceiling Throughout Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-01

1Lead 01/29/24 LP 01/30/24 pmx<0.015 % wt 0.015 % wt SW-846

3050B

SW846-7000B0.265

Sample Comments:

Client Sample ID: P-2/Yellow Concrete Basement Walls and Columns Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-02

1Lead 01/29/24 LP 01/30/24 pmx<0.017 % wt 0.017 % wt SW-846

3050B

SW846-7000B0.234

Sample Comments:

Client Sample ID: P-3/White Plaster 1st Floor Ceiling, North Entrance Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-03

1Lead 01/29/24 LP 01/30/24 pmx0.054 % wt 0.021 % wt SW-846

3050B

SW846-7000B0.1931

Sample Comments:

Client Sample ID: P-4/White Plaster 1st Floor Wall, South Restroom Hall Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-04

1Lead 01/29/24 LP 01/30/24 pmx0.16 % wt 0.016 % wt SW-846

3050B

SW846-7000B0.2501

Sample Comments:

Client Sample ID: P-5/Blue Drywall 1st Floor Wall, South Restroom Hall Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-05

1Lead 01/29/24 LP 01/30/24 pmx<0.014 % wt 0.014 % wt SW-846

3050B

SW846-7000B0.2837

Sample Comments:

Client Sample ID: P-6/Grey Drywall 2nd Floor Wall, North Office Area Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-06

1Lead 01/29/24 LP 01/30/24 pmx0.075 % wt 0.046 % wt SW-846

3050B

SW846-7000B0.0861

Sample Comments:

Client Sample ID: P-7/Aqua Plaster 2nd Floor Wall, North Office Area Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-07

1Lead 01/29/24 LP 01/30/24 pmx0.10 % wt 0.015 % wt SW-846

3050B

SW846-7000B0.2605

Sample Comments:

Client Sample ID: P-8/Grey Drywall 2nd Floor Wall, South Office Area Date Sampled: 01/26/24

Matrix: Chips LIMS Reference ID: AC06654-08

1Lead 01/29/24 LP 01/30/24 pmx<0.015 % wt 0.015 % wt SW-846

3050B

SW846-7000B0.2659

Sample Comments:

[TOC_1]Sample Results[TOC]

Page 1 of 4Page 1 of 5

EMSL Sales Rep:

Reported:

Atlas Technical [ATC55]

11117 Mockingbird Drive

Omaha, NE 68137

EMSL Analytical, Inc.

200 Route 130, Cinnaminson, NJ, 08077

Telephone: 856-858-4800 Fax:856-786-5974

EMSL-CIN-01

Allison NicholsAttention:

(402) 697-9747

Allison.Williams@oneatlas.com Received: 01/29/2024 09:00

01/30/2024 18:16

Anthony DeRosa

EMSL Order ID: 012406654

LIMS Reference ID: AC06654

EMSL Customer ID: ATC55

204BS06748

CertificationsAnalyte

Certified Analyses included in this Report

SW846-7000B in Chips

AIHA LAPLead

[TOC_1]Certified

Analyses[TOC]

List of Certifications

Code Description Number Expires

NJDEP 03036New Jersey Department of Environmental Protection 06/30/2024

AIHA LAP 100194EMSL Analytical, Inc. Cinnaminson, NJ AIHA-LAP, LLC-ELLAP Accredited 01/01/2025

NYSDOH 10872New York State Department of Health 04/01/2024

California ELAP 1877California Water Boards 06/30/2024

A2LA 2845.01A2LA Environmental Certificate 07/31/2024

PADEP 68-00367Pennsylvania Department of Environmental Protection 11/30/2023

MADEP M-NJ337Massachusetts Department of Environmental Protection 06/30/2024

CTDPH PH-0270Connecticut Department of Public Health 06/23/2024

Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.

Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.

[TOC_1]Certifications[TOC]

Page 2 of 4Page 2 of 5

EMSL Sales Rep:

Reported:

Atlas Technical [ATC55]

11117 Mockingbird Drive

Omaha, NE 68137

EMSL Analytical, Inc.

200 Route 130, Cinnaminson, NJ, 08077

Telephone: 856-858-4800 Fax:856-786-5974

EMSL-CIN-01

Allison NicholsAttention:

(402) 697-9747

Allison.Williams@oneatlas.com Received: 01/29/2024 09:00

01/30/2024 18:16

Anthony DeRosa

EMSL Order ID: 012406654

LIMS Reference ID: AC06654

EMSL Customer ID: ATC55

204BS06748

Notes and Definitions

Item Definition

(Dig) For metals analysis, sample was digested.

[2C] Reported from the second channel in dual column analysis.

DF Dilution Factor

MDL Method Detection Limit.

ND Analyte was NOT DETECTED at or above the detection limit.

Q Qualifier

RL Reporting Limit

For paint chips, the RL is 0.008% by wt. (equiv. to 80 mg/kg, or ppm) based upon a minimum sample weight of 0.25 grams.

For soils, the RL is 40 mg/kg (ppm) based upon a minimum sample weight of 0.5 grams.

For dust wipes, the RL is 10 µg/wipe; reporting units of µg/sq. ft. are not validated by the lab based upon data provided by non-lab personnel.

Measurement of uncertainty and any applicable definitions of method modifications are available upon request. Per EPA NLLAP policy, sample results are not blank corrected.

[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]

EMSL maintains liability limited to coast of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. QC sample results are within quality control criteria and met method specifications unless otherwise noted.

Owen McKenna Laboratory Manager or other approved signatory

Analysis following EMSL SOP for the Determination of Environmental Lead by FLAA. The laboratory has a reporting limit of 0.008% by wt., based upon a minimum sample weight of

0.25g submitted to the lab, and is not responsible for any result or reporting limit provided in mg/cm2 since it is dependent upon an area value provided by non-lab personnel. A "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty and definitions of modifications are available upon request. Results in this report are not blank corrected unless specified.

Page 3 of 4Page 3 of 5

APPENDIX C

ASBESTOS SAMPLE LOCATIONS

APPENDIX D

STAFF ACCREDITATIONS

4503 East 50th Street, Suite 800, Des Moines, Iowa 50317

515.981.4528 | oneatlas.com

HAZARDOUS BUILDING MATERIALS SURVEY

REPORT

PREPARED FOR:

2929 Westown Parkway, Suite 200

West Des Moines, Iowa 50309

PROJECT LOCATION:

Elementary School Building – Fire Alarm Replacement Project Iowa School for the Deaf

Project Date: February 2, 2024

Report Date: February 20, 2024

Atlas Project ID: 204BS06743

PREPARED BY:

Atlas Technical Consultants 4503 E 50th Street, Suite 800

Des Moines, IA 50317 i

February 20, 2024

Mr. Jerry Dehnke 2929 Westown Parkway, Suite 200 West Des Moines, Iowa 50309

Re: Hazardous Building Materials Survey Report

Elementary School Building – Fire Alarm Replacement Project Iowa School for the Deaf

Atlas Project Number: 204BS06743

Atlas is pleased to submit the attached Hazardous Building Materials Survey Report for the above-referenced site. This report includes procedures, methodologies and analytical laboratory results.

Atlas appreciates the opportunity to perform these services for the IDAS and the Samuels Group, and we look forward to working with you in the future. If you need any assistance with the implementation of the recommendations contained in this report, please feel free to give us a call at (402) 670-3842 and we will respond promptly to your needs.

Sincerely, ATLAS TECHNICAL CONSULTANTS, LLC

Prepared By: Reviewed By:

Trevor Parks, CSMI Steve Hudson, MS, CIH, CIEC Environmental Scientist Sr. Project Manager (402)-697-9747 (402) 670-3842

T A B L E O F C O N T E N T S

LETTER OF TRANSMITTAL ...................................................................................... i

1.0 SCOPE OF SERVICES

2.0 GENERAL SITE CONDITIONS

3.0 ASBESTOS SURVEY REPORT

3.1 Regulation Review

3.2 Homogeneous Areas

3.3 Sampling Strategy

3.4 Suspect Asbestos-Containing Materials

3.5 Laboratory Analytical Results

4.0 LEAD PAINT SURVEY

4.1 Inspection

4.2 Lead Paint Testing

5.0 HAZARDOUS MATERIALS ASSESSMENT

6.0 CONCLUSIONS

7.0 ASSUMPTIONS AND LIMITATIONS

APPENDICES

APPENDIX A ASBESTOS TEST RESULTS

APPENDIX B LEAD PAINT TEST RESULTS

APPENDIX C SAMPLE LOCATIONS

APPENDIX D INSPECTOR ACCREDITATIONS

Elementary School Building Council Bluffs, Iowa

February 20, 2024 Project No. 204BS06743

H A Z A R D O U S B U I L D I N G M A T E R I A L S

S U R V E Y R E P O R T

Elementary School Building Iowa School for the Deaf

Council Bluffs, Iowa 51503 Atlas Project Number: 204BS06743

1.0 SCOPE OF SERVICES

The purpose of this project was to perform a survey for hazardous building materials that may be impacted by planned fire alarm replacement activities at the above-referenced property.

Atlas provided a representative hazardous materials survey in accordance with the referenced agreement and as outlined below:

1. Review any existing hazardous building material survey reports relating to the site, if available.

2. Identify suspect asbestos-containing materials (ACM), surface coatings potentially containing lead paint, and hazardous building materials within the planned fire alarm replacement work areas.

3. Collect and analyze bulk samples of suspect asbestos containing materials and collect paint chip samples from representative surface coatings potentially containing lead-based or lead-containing paint.

4. Provide laboratory analysis of collected samples.

5. Provide a report of findings with copies and interpretation of analytical results and identifying the locations of asbestos-containing materials, lead paint, and hazardous building materials.

2.0 GENERAL SITE CONDITIONS

The survey was conducted at the Elementary School Building located at the Iowa School for the Deaf in Council Bluffs, Iowa. The survey area was limited to the areas to be disturbed as part of planned fire alarm replacement activities.

3.0 ASBESTOS SURVEY

On February 2, 2024, the basement, first, and second floors of the Elementary School Building were inspected for asbestos-containing building materials by inspector Chase Bucknell of Atlas. Mr. Bucknell has completed the requisite training for asbestos accreditation as inspectors at a state approved training provider under TSCA Title II. Mr. Bucknell’s State of Iowa Inspector number is 23- 9762.

The planned renovation work areas were visually inspected for the presence of suspect asbestos-containing materials (ACM). Materials that were hidden, not accessible, or when sampled would damage the integrity of the structure, were not sampled as part of this survey. Materials visibly identified as non-asbestos (fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos survey consisted of three basic steps: 1) a visual inspection of the proposed work areas; 2) a determination of homogeneous areas with suspect surfacing, thermal system insulation, and miscellaneous materials; and 3) sampling accessible, friable and non-friable, suspect materials.

3.1 Regulation Review

The U.S. EPA qualifies asbestos-containing materials (ACM) as materials with an asbestos content greater than 1%. The following definitions are taken from Section

61.141 of Subpart M, Part 61 of Title 40: Protection of Environment of the Code of Federal Regulations (CFR).

• “Category I non-friable asbestos-containing material (ACM)” is defined as asbestos-containing packings, gaskets, resilient floor covering, and asphalt roofing products containing more than 1% asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy (PLM).

• “Category II non-friable ACM” is defined as any material, excluding Category I non-friable ACM, containing more than 1% asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, PLM that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

• “Friable asbestos material” is defined as any material containing more than 1% asbestos as determined using the methods specified in appendix E, subpart E, 40 CFR part 763, section 1, PLM that when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. If the asbestos content is less than 10% as determined by a method other than point counting by PLM, verify the asbestos content by point counting using

PLM.

3.2 Homogeneous Areas

Prior to sampling, homogeneous areas were identified in order to facilitate a sampling strategy. A homogeneous sampling area can be described as one or more areas with suspect material similar in appearance and texture that have the same installation date and function. The actual number of samples collected from each homogeneous sampling area may vary, dependent upon material type and the professional judgment of the inspector.

3.3 Sampling Strategy

The sampling strategy incorporated AHERA requirements, quantities of suspect material, and the inspector’s judgment to aid in the identification of suspect asbestos-containing materials. If the analytical results indicated that all the samples collected per homogeneous area did not contain asbestos, then the homogeneous area (material) was considered non-asbestos-containing. However, if the analytical results of one or more of the samples collected per homogeneous area indicated that asbestos was present in quantities greater than one percent asbestos (as defined by EPA), all of the homogeneous area (material) was treated as an asbestos-containing material regardless of any other analytical results. Materials which were visually determined to be non-asbestos (i.e. fibrous glass, foam rubber, etc.) by the accredited inspector were not required to be sampled. Actual collection of a bulk asbestos sample involves physically removing approximately one square inch (1 in2) of material and placing it in an airtight sample container. Sample containers were marked with a unique identification number, which was documented in the field notes.

3.4 Suspect Asbestos-Containing Materials

The following table contains a list of the twenty (20) identified suspect asbestos containing materials sampled:

MATERIAL LOCATION SAMPLE NUMBER

Hockey Puck Brown Glue Hallway Outside Room 121 1

Pinhole Fissure 2’ x 4’ Ceiling Tiles Hallway Outside Room 121 2

Pinhole Fissure 2’ x 4’ Ceiling Tiles Hallway Outside Room 103 3

Pinhole Fissure 2’ x 4’ Ceiling Tiles Hallway Outside Room 203 4

12” x 12” Ceiling Tiles Hallway Outside Room 121 5

12” x 12” Ceiling Tiles Hallway Outside Room 103 6

12” x 12” Ceiling Tiles Hallway Outside Room 202 7

Plaster Hallway Outside Room 121 8

Plaster Hallway Outside Room 103 9

Plaster Bathroom By Room 114 10

Pinhole 2’ x 4’ Ceiling Tiles Hallway Outside Room 103 11

Pinhole 2’ x 4’ Ceiling Tiles Hallway Outside Room 203 12

MATERIAL LOCATION SAMPLE NUMBER

Pinhole 2’ x 4’ Ceiling Tiles Hallway Outside Room 213 13

Ceiling Texture (white) Stairway/Exit by Room 103 14

Ceiling Texture (white) Staircase by Room 202 15

Ceiling Texture (white) Staircase by Room 217 16

Drywall and Joint Compound Room 203 17

Drywall and Joint Compound Room 213 18

Drywall and Joint Compound Room 114 19

Grout Concrete Basement Stair Case 20

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

T A B L E 2 : A S B E S T O S - C O N T A I N I N G M A T E R I A L S

MATERIAL LOCATION

SAMPLE

NUMBER

APPROX.

QUANTITY

ASBESTOS

CONTENT

Brown Adhesive Pucks Under 12x12 Ceiling Tiles

1st Floor - Outside Room 121

1 1st Floor 3% Chrysotile

Joint Compound 2nd Floor - Room

18 2nd Floor 3% Chrysotile

Joint Compound 1st Floor - Room

19 1st Floor 3% Chrysotile

SF = Square Feet, LF = Linear Feet MF = Mechanical Fittings

3.5 Laboratory Analytical Results

Bulk samples were analyzed by EMSL Analytical, Inc. located at 200 Route 130 North, Cinnaminson, NJ. Polarized Light Microscope analysis, utilizing dispersion staining techniques (ref.: EPA Method 600/M4-82-020), was performed to determine the asbestos content of the bulk samples collected at the site. This laboratory is currently a proficient participant in the American Industrial Hygiene Association (AIHA) Bulk Asbestos Proficiency Analytical Testing Program; a quality assurance program for polarized light microscopy analysis. Any material that contains greater than one percent asbestos is considered an ACM and must be handled according to Occupational Safety and Health Administration (OSHA), EPA, and all applicable state and local regulations.

Laboratory test results are provided in Appendix A.

4.0 LEAD PAINT SURVEY

On February 2, 2024, the Elementary School Building was inspected for lead paint by Tim Jacobsen of Atlas. The purpose of the survey was to identify locations and concentrations of lead in paints and coatings on interior building components that may be disturbed as part of planned fire alarm replacement activities.

4.1 Inspection

The lead survey was performed in general accordance with the U.S. Housing and Urban Development Chapter 7 of the Guidelines for the evaluation and Control of Lead-Based Paint Hazards in Housing (1997 Revision). Survey criteria included the inspection and sampling of the representative painted surfaces on the interior of the building.

Regulatory limits from the Housing and Urban Development (HUD) and the Environmental Protection Agency (EPA) establishes that lead-based paint (LBP) by definition is paint that contains more than 0.5% of lead in paint. OSHA’s “Lead in Construction Standard” (29 CFR 1926.1101) addresses any concentration of lead in paint (“lead-containing paint”).

Prior to demolition or renovation activities, all contractors involved should be notified regarding the presence of painted components under the guidelines of the OSHA Lead in Construction standard 29 CFR 1926.62. Care should be exercised in acknowledging that the OSHA 29 CFR 1926.62 has no LBP threshold definition and is concerned with exposures generated by LBP disturbances, which may include materials containing less than 0.5% lead by weight. The OSHA regulations are based strictly on airborne lead concentrations; therefore, the measured lead concentration of the paint and the method of paint disturbance will both factor into the potential airborne hazard.

OSHA requires the contractor to inform its employees of potential lead hazards, based upon the work being performed. The purpose of OSHA’s Lead Construction Standard is to reduce the exposure to lead for all construction workers. It is for this reason that Atlas recommends contractors be informed of the presence of lead.

OSHA’s standard includes an 8-hour time weighted average (TWA) of 50 micrograms of lead per cubic meter of air (mg/m3) and an action level (regardless of respirator use) of 30 mg/m3.

Prior to disposal of debris that contains materials that have been found to contain lead, conduct a Toxicity Characteristic Leaching Procedures (TCLP) on representative solid wastes. This will determine if the debris requires a hazardous waste disposal site. A TCLP was not collected as part of this current inspection.

4.2 Lead Paint Testing

A total of seven (7) surface coatings were tested to determine the concentration of lead. The sampling generally involved the collection of the paint on the surface down to the substrate over an area of approximately 2 to 3 square inches. A summary of the tested paints is provided in the table below. In order for a surface coating to be considered a lead-based paint, the paint must contain lead in concentrations greater than 0.5% by weight. A detectable concentration of lead in the surface coating below 0.5% by weight is considered a lead-containing paint.

The full copy of the lead analytical results is included in Appendix B.

• Lead-based paint was not identified in any of the surface coatings tested.

This evaluation report can help the Owner develop a plan for renovating the building by having concentrations of lead in the paint identified. It is our understanding that the information in this report will be provided to the contractors so that appropriate precautions can be made to minimize worker exposure to lead.

If surface coatings with lead containing paint are handled improperly, exposure could occur to workers and future occupants of the facility.

5.0 HAZARDOUS MATERIALS ASSESSMENT

Atlas completed a visual inspection of rooms / areas throughout the intended work areas to identify hazardous wastes or universal wastes that may be impacted by planned renovation activities. The survey included a visual inspection of: light fixtures and other equipment for the presence of Polychlorinated Biphenyls (PCBs); light bulbs, thermostats, switches, and other equipment for the presence of mercury; refrigerants, batteries, and devices with potential radioactive materials.

Category Material Estimated Quantity

Poly-Chlorinated Biphenyl

(PCBs)

Transformers N/A

Transistors N/A

Light Ballasts N/A

Mercury

Thermostats N/A

Switches/Relays N/A

Fluorescent Light Tubes N/A

High Intensity Discharge lights N/A

Thermometers/ Manometers N/A

Category Material Estimated Quantity

Batteries

Smoke Detectors 76

Emergency Lighting Systems 1

Exit Signs 9

Flashing Fire Alarms 37

Chlorofluorocarbons

(CFCs) or

Hydro

Chlorofluorocarbons

(HCFCs)

Refrigerators/Freezers/Chillers N/A

Low Level Radioactive

Sources (LLR) Smoke/Fire Alarms 76

Hazardous materials or universal wastes identified in Table 3 shall be removed as part of the renovation contractor’s scope of work and disposed of according to US EPA Toxic Substances Control Act (TSCA) and the State of Iowa regulations.

6.0 CONCLUSIONS

The following conclusions are summarized as follows:

• Asbestos was identified in the adhesive pucks behind the 12x12 ceiling tiles on the 1st floor, and joint compound on the 2nd floor and 1st floor.

• Lead-based paint was not identified in the suspect surface coatings tested.

7.0 ASSUMPTIONS AND LIMITATIONS

The results, findings, conclusions, and recommendations expressed in this report are based solely on conditions noted during the February 2, 2024, Atlas hazardous building materials survey of the Elementary School Building located at the Iowa School for the Deaf in Council Bluffs, Iowa. The survey was limited to surfaces to be impacted by planned fire alarm replacement activities.

Atlas did not perform destructive sampling -- it was not within Atlas’s scope of work to remove surface materials to investigate portions of the structure or materials that may lay beneath the surface -- thus, any materials that could not be visually identified on the surface were not inspected and would not be noted in this report.

Atlas’s selection of sample locations and frequency of sampling was based on the inspector’s assumption that like materials in the same area are homogeneous in content.

The report is designed to aid the building owner, architect, construction manager, general contractor, and potential abatement…