WARNING

Restricted Area

It is unlawful to enter this area without permission of the Installation Commander.

Sec. 21, Internal Security Act of 1950; 50 U.S.C. 797

While on this Installation all personnel and the property under their control are subject to search.

Use of deadly force authorized.

HAZARDOUS AREA - STAND CLEAR DURING DOOR OPERATION

DANGER

DT2

AutoCAD SHX Text 6"

AutoCAD SHX Text

RESTRICTED AREA LINE

AutoCAD SHX Text

6" RED STRIPE W/ EMBEDDED GLASS BEADS.

AutoCAD SHX Text

ECP

AutoCAD SHX Text

RESTRICTED AREA ENTRY CONTROL POINT LOCATION DESIGNATION

AutoCAD SHX Text 12", BLACK, BLOCK LETTERS ON A WHITE BACKGROUND. BACKGROUND TO BE 18" TALL. WIDTH TO BE AS NECESSARY TO ACCOMMODATE THE LETTERS WITH A 3" BORDER OUTSIDE OF THEM.

AutoCAD SHX Text 18"

AutoCAD SHX Text

FIRE DEPT BUILDING CONNECTION CLEAR AREA

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text 5'-0"

AutoCAD SHX Text 5'-0"

AutoCAD SHX Text 45°

AutoCAD SHX Text

TYP.

AutoCAD SHX Text

CENTER MARKINGS ON BUILDING CONNECTION PIPE

AutoCAD SHX Text

4" RED STRIPES TYPICAL

AutoCAD SHX Text

BLACK PAINT

AutoCAD SHX Text

2" LETTERING

AutoCAD SHX Text

RED PAINT

AutoCAD SHX Text

BLACK PAINT

AutoCAD SHX Text

BLACK PAINT

AutoCAD SHX Text

WHITE PAINT

AutoCAD SHX Text

1" LETTERING

AutoCAD SHX Text NOTE: 1. SIGNAGE TO BE PLACED AROUND ALL SIGNAGE TO BE PLACED AROUND ALL GROUNDING POINTS.

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

STATIC GROUND

AutoCAD SHX Text 18"

AutoCAD SHX Text NOTES: 1. WARNING SIGN SIZE AND LAYOUT SHALL MATCH EXISTING. WARNING SIGN SIZE AND LAYOUT SHALL MATCH EXISTING. 2. WARNING SIGN TEMPLATE SHALL BE APPROVED BY CONTRACTING WARNING SIGN TEMPLATE SHALL BE APPROVED BY CONTRACTING OFFICER PRIOR TO ORDERING. 3. RESTRICTED AREA WARNING SIGNS SHALL BE PLACED ON THE PAVEMENT RESTRICTED AREA WARNING SIGNS SHALL BE PLACED ON THE PAVEMENT ALONGSIDE THE RED RESTRICTED AREA LINE AT A MAXIMUM SPACING OF 100' O.C. VERIFY EXISTING SPACING IN FIELD. WARNING SIGNS MUST ALSO BE PLACED AT DIRECTIONAL CHANGES (CURVES AND CORNERS) IN THE RESTRICTED AREA LINE. ALL SIGNS ARE TO BE LOCATED OUTSIDE OF THE RESTRICTED AREA WITH 6" SPACING BETWEEN EDGE OF SIGN AND RESTRICTED AREA LINE.

AutoCAD SHX Text

STATIC GROUNDING POINT

AutoCAD SHX Text

2 INCH OUTLINE (BLACK PAINT)

AutoCAD SHX Text

4" LETTERING

AutoCAD SHX Text

3/4" LETTERING

AutoCAD SHX Text

3/4" LETTERING

AutoCAD SHX Text

RESTRICTED AREA WARNING SIGN PAVEMENT MARKING DETAIL

AutoCAD SHX Text

RED PAINT

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

1 INCH BLOCK LETTERS (BLACK PAINT)

AutoCAD SHX Text

STATIC GROUND POINT LOCATION DESIGNATION

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

REQUIRED WIDTH OF ENTRY CONTROL POINT (ECP)

AutoCAD SHX Text

6" WIDE NON-REFLECTIVE BLACK BORDER LINE

AutoCAD SHX Text

12" X 3'-0 YELLOW BLOCK

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AIRCRAFT PARKING SPOT NOSE WHEEL LOCATION DESIGNATION

AutoCAD SHX Text

6" STRIPE TYPICAL

AutoCAD SHX Text

6" SPACE TYPICAL

AutoCAD SHX Text

3'-0" CTR'D IN SPACE, TYPICAL

AutoCAD SHX Text

ECP SIGN, PER DETAIL THIS SHEET

AutoCAD SHX Text

RESTRICTED AREA WARNING SIGN, PER DETAIL THIS SHEET

AutoCAD SHX Text

RESTRICTED AREA ENTRY CONTROL POINT LOCATION MARKINGS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

ECP SIGN, PER DETAIL THIS SHEET

AutoCAD SHX Text

RESTRICTED AREA WARNING SIGN, PER DETAIL THIS SHEET

AutoCAD SHX Text NOTE: TAXI LINE SHALL BE INTERRUPTED AT BLACK BORDER ON EITHER SIDE OF YELLOW BLOCK

AutoCAD SHX Text 4"

AutoCAD SHX Text 1'-8"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 15'-6"

AutoCAD SHX Text 2'-4"

AutoCAD SHX Text YELLOW PAINTED HAZARD ZONE. PROVIDE NON SKID ADDITIVE TO PAINT AS RECOMMENDED BY MANUF.

AutoCAD SHX Text

CENTERLINE HANGAR DOOR, AND WARNING SIGNAGE

AutoCAD SHX Text

4" WHITE PAINTED LETTERS, HELVETICA BOLD UPPER CASE, CENTERED IN BLACK BOX

AutoCAD SHX Text 5'-0"

AutoCAD SHX Text

EQ

AutoCAD SHX Text

EQ

AutoCAD SHX Text

4" RED PAINTED LETTERS, HELVETICA BOLD UPPER CASE

AutoCAD SHX Text

HANGAR DOOR HAZARDOUS ZONE MARKINGS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text WHERE SIGN IS TO BE PAINTED OVER AN AIRFIELD RESTRICTED AREA INTRUSION DETECTION SYSTEM EMBEDDED CABLE, THE SIGN WILL BE ADJUSTED SO THAT THE CABLE IS NOT UNDER SIGN TEXT.

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

VERMONT AIR NATIONAL GUARD

AutoCAD SHX Text 158th FW

AutoCAD SHX Text

BURLINGTON VERMONT

AutoCAD SHX Text

BURLINGTON INTERNATIONAL AIRPORT

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

NO

AutoCAD SHX Text

REPAINT

AutoCAD SHX Text

AIRFIELD

AutoCAD SHX Text

MARKINGS

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

RTL

AutoCAD SHX Text

RTL

AutoCAD SHX Text

MWL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

CURZ202303

AutoCAD SHX Text

MAR 2020

Sheets and Views
DT2 - Details