WARNING
Restricted Area
It is unlawful to enter this area without permission of the Installation Commander.
Sec. 21, Internal Security Act of 1950; 50 U.S.C. 797
While on this Installation all personnel and the property under their control are subject to search.
Use of deadly force authorized.
HAZARDOUS AREA - STAND CLEAR DURING DOOR OPERATION
DANGER
DT2
AutoCAD SHX Text 6"
AutoCAD SHX Text
RESTRICTED AREA LINE
AutoCAD SHX Text
6" RED STRIPE W/ EMBEDDED GLASS BEADS.
AutoCAD SHX Text
ECP
AutoCAD SHX Text
RESTRICTED AREA ENTRY CONTROL POINT LOCATION DESIGNATION
AutoCAD SHX Text 12", BLACK, BLOCK LETTERS ON A WHITE BACKGROUND. BACKGROUND TO BE 18" TALL. WIDTH TO BE AS NECESSARY TO ACCOMMODATE THE LETTERS WITH A 3" BORDER OUTSIDE OF THEM.
AutoCAD SHX Text 18"
AutoCAD SHX Text
FIRE DEPT BUILDING CONNECTION CLEAR AREA
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text 45°
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
CENTER MARKINGS ON BUILDING CONNECTION PIPE
AutoCAD SHX Text
4" RED STRIPES TYPICAL
AutoCAD SHX Text
BLACK PAINT
AutoCAD SHX Text
2" LETTERING
AutoCAD SHX Text
RED PAINT
AutoCAD SHX Text
BLACK PAINT
AutoCAD SHX Text
BLACK PAINT
AutoCAD SHX Text
WHITE PAINT
AutoCAD SHX Text
1" LETTERING
AutoCAD SHX Text NOTE: 1. SIGNAGE TO BE PLACED AROUND ALL SIGNAGE TO BE PLACED AROUND ALL GROUNDING POINTS.
AutoCAD SHX Text
ONLY
AutoCAD SHX Text
STATIC GROUND
AutoCAD SHX Text 18"
AutoCAD SHX Text NOTES: 1. WARNING SIGN SIZE AND LAYOUT SHALL MATCH EXISTING. WARNING SIGN SIZE AND LAYOUT SHALL MATCH EXISTING. 2. WARNING SIGN TEMPLATE SHALL BE APPROVED BY CONTRACTING WARNING SIGN TEMPLATE SHALL BE APPROVED BY CONTRACTING OFFICER PRIOR TO ORDERING. 3. RESTRICTED AREA WARNING SIGNS SHALL BE PLACED ON THE PAVEMENT RESTRICTED AREA WARNING SIGNS SHALL BE PLACED ON THE PAVEMENT ALONGSIDE THE RED RESTRICTED AREA LINE AT A MAXIMUM SPACING OF 100' O.C. VERIFY EXISTING SPACING IN FIELD. WARNING SIGNS MUST ALSO BE PLACED AT DIRECTIONAL CHANGES (CURVES AND CORNERS) IN THE RESTRICTED AREA LINE. ALL SIGNS ARE TO BE LOCATED OUTSIDE OF THE RESTRICTED AREA WITH 6" SPACING BETWEEN EDGE OF SIGN AND RESTRICTED AREA LINE.
AutoCAD SHX Text
STATIC GROUNDING POINT
AutoCAD SHX Text
2 INCH OUTLINE (BLACK PAINT)
AutoCAD SHX Text
4" LETTERING
AutoCAD SHX Text
3/4" LETTERING
AutoCAD SHX Text
3/4" LETTERING
AutoCAD SHX Text
RESTRICTED AREA WARNING SIGN PAVEMENT MARKING DETAIL
AutoCAD SHX Text
RED PAINT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
1 INCH BLOCK LETTERS (BLACK PAINT)
AutoCAD SHX Text
STATIC GROUND POINT LOCATION DESIGNATION
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
REQUIRED WIDTH OF ENTRY CONTROL POINT (ECP)
AutoCAD SHX Text
6" WIDE NON-REFLECTIVE BLACK BORDER LINE
AutoCAD SHX Text
12" X 3'-0 YELLOW BLOCK
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AIRCRAFT PARKING SPOT NOSE WHEEL LOCATION DESIGNATION
AutoCAD SHX Text
6" STRIPE TYPICAL
AutoCAD SHX Text
6" SPACE TYPICAL
AutoCAD SHX Text
3'-0" CTR'D IN SPACE, TYPICAL
AutoCAD SHX Text
ECP SIGN, PER DETAIL THIS SHEET
AutoCAD SHX Text
RESTRICTED AREA WARNING SIGN, PER DETAIL THIS SHEET
AutoCAD SHX Text
RESTRICTED AREA ENTRY CONTROL POINT LOCATION MARKINGS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
ECP SIGN, PER DETAIL THIS SHEET
AutoCAD SHX Text
RESTRICTED AREA WARNING SIGN, PER DETAIL THIS SHEET
AutoCAD SHX Text NOTE: TAXI LINE SHALL BE INTERRUPTED AT BLACK BORDER ON EITHER SIDE OF YELLOW BLOCK
AutoCAD SHX Text 4"
AutoCAD SHX Text 1'-8"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 15'-6"
AutoCAD SHX Text 2'-4"
AutoCAD SHX Text YELLOW PAINTED HAZARD ZONE. PROVIDE NON SKID ADDITIVE TO PAINT AS RECOMMENDED BY MANUF.
AutoCAD SHX Text
CENTERLINE HANGAR DOOR, AND WARNING SIGNAGE
AutoCAD SHX Text
4" WHITE PAINTED LETTERS, HELVETICA BOLD UPPER CASE, CENTERED IN BLACK BOX
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EQ
AutoCAD SHX Text
4" RED PAINTED LETTERS, HELVETICA BOLD UPPER CASE
AutoCAD SHX Text
HANGAR DOOR HAZARDOUS ZONE MARKINGS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text WHERE SIGN IS TO BE PAINTED OVER AN AIRFIELD RESTRICTED AREA INTRUSION DETECTION SYSTEM EMBEDDED CABLE, THE SIGN WILL BE ADJUSTED SO THAT THE CABLE IS NOT UNDER SIGN TEXT.
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
VERMONT AIR NATIONAL GUARD
AutoCAD SHX Text 158th FW
AutoCAD SHX Text
BURLINGTON VERMONT
AutoCAD SHX Text
BURLINGTON INTERNATIONAL AIRPORT
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
NO
AutoCAD SHX Text
REPAINT
AutoCAD SHX Text
AIRFIELD
AutoCAD SHX Text
MARKINGS
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
RTL
AutoCAD SHX Text
RTL
AutoCAD SHX Text
MWL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
CURZ202303
AutoCAD SHX Text
MAR 2020