Attachment G - Drawing CG2-M-20-U-0018-R00 and Subdrawings.pdf

PDF 5 MB Posted

Attached to
ORNL High Flux Isotope Reactor GP-SANS Polarizer
Solicitation number
PR449089
Issued by

About this file

This document is a technical drawing set for the HFIR Instrument CG-2 GP-SANS V-Cavity Magnetic Casing Assembly, a component for Oak Ridge National Laboratory's High Flux Isotope Reactor.

The assembly consists of multiple detailed engineering drawings (CG2-M-20-U-0018 through CG2-M-20-U-0030) that specify fabrication requirements for the complete casing system. Key components include: V-cavity aluminum walls (6061 aluminum), steel walls (A36 steel), magnetic casing magnet assemblies incorporating neodymium block magnets, borated aluminum shielding panels (31% boron-10 composition), steel lifting blocks, temporary aluminum plates for assembly, and various fasteners including stainless steel hex head cap screws and American Drill and Bushing swivel hoist rings. The assembly weighs approximately 71 pounds and uses electroless nickel coating per ASTM B733 specifications with 0.001-inch thickness classification SC3 (moderate service), Type 1, post-heat treatment Class 1. Critical fabrication notes specify handling precautions for neodymium magnets, material cleanliness requirements using water-soluble non-sulfurous cutting oils, deionized water rinsing, and specific packaging in polyethylene bags to prevent vacuum volume contamination. All drawings reference drawing number CG2-M-20-U-0018 as the parent assembly with revision 0 dated October 22, 2025, and prohibit vendor substitution without prior engineering approval. Tolerances follow ASME Y14.100 drafting standards and Y14.5 geometric dimensioning specifications.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7 6 5 4 3 2 18

A

C

D

A

B

C

D

B

( )6.43

( )59.06

( )3.49

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

THIS DRAWING IS THE PROPERTY OF OAK RIDGE NATIONAL LABORATORY.

APPROVAL BLOCK

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/22/2025

NEXT USED ASSEMBLY

UNITS: INCHES

DEFAULT TOLERANCES

X.XX �#�.01

X.XXX �#�.005

ANGULAR �#�.5

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

V-CAVITY MAGNETIC CASING ASSEMBLY

DRAWING NUMBER REV

CG2-M-20-U-0018 0

SIZE SCALE WEIGHT SHEET

D 1:4 71 LB 1 of 1VENDOR

MATERIAL

SPECIFICATION

DESCRIPTION PART NUMBER QTY

FIND

NO.

V-CAVITY MAGNETIC CASING MAGNET ASSEMBLY CG2-M-20-U-0023 2 1

V-CAVITY CASING STEEL WALL & LIFTING BLOCK ASSEMBLY CG2-M-20-U-0026 1 2

STEEL

A36 (K02600)

STEEL WALL FOR MAGNETIC CASING CG2-M-20-U-0024 1 3

McMASTER-CARR

WWW.MCMASTER.COM

18-8 STAINLESS STEEL

ASME B18.3, ASTM F879

FHSCS, 1/4- 20 UNC-3A X 0.75" LG 92210A540 8 4

MCMASTER-CARR

WWW.MCMASTER.COM

316 SS

FHSHC SS #8-32 UNC X 3/4 LG 92210A197 16 5

AMERICAN DRILL AND BUSHING

https://americandrillbushing.com/

ALLOY STEEL

AMERICAN DRILL AND BUSHING SWIVEL HOIST RING 23053 23053 2 6

AL EN6061 31% BORON-10

BORATED ALUMINUM FOR V-CAVITY SHIELDING STEEL WALL SIDE CG2-M-20-U-0029 2 7

AL EN6061 31% BORON-10

BORATED ALUMINUM FOR V-CAVITY SHIELDING ALUMINUM WALL SIDE CG2-M-20-U-0030 2 8

NOTES:

1. VENDORS AND VENDOR SPECIFIC ITEMS MAY NOT BE SUBSTITUTED WITHOUT PRIOR ENGINEERING APPROVAL.

2. CAUTION: HANDLING OF NEODYMIUM MAGNETS CAN CAUSE INJURY, REVIEW SAFETY DATA SHEET

AND ENSURE APPROPRIATE CONTROL OF HAZARDS ARE IN PLACE PRIOR TO HANDLING.

SCALE 1:2

6s9 Initials

A

C

D

A

B

C

D

B

98X 0.31

99X 0.28

99X 0.06

99X 0.15

0.75

59.06

0.65

99X 0.53

6X 0.38

2X 12.81

2X

396X R0.0156

6x 0.38

2X 0.25

11.64

23.37

35.1

46.83

12.22

23.95

35.69

47.42

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/22/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0023

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

V-CAVITY ALUMINUM WALL FOR MAGNETIC CASING

DRAWING NUMBER REV

CG2-M-20-U-0019 0

SIZE SCALE WEIGHT SHEET

D 1:4 6 LB 1 of 1

SPECIFICATIONMATERIAL

6061ALUMINUM

FRONT VIEW

BACK VIEW

NOTES:

1 METAL STAMP OR ETCH " CG2-M-20-U-0019 " IN 1/4 INCH MINIMUM HIGH LETTERS ON BOTTOM SURFACE.

2. REMOVE ALL CONTAMINATION E.G. SCALE, DIRT, GREASE AND OIL PRIOR TO FABRICATION BY WIPING

MATERIAL DOWN WITH A CLEAN CLOTH OR PAPER TOWEL.

3. USE ONLY WATER SOLUBLE, NON-SULFUROUS BEARING CUTTING OILS FOR MACHINING.

4. WASH ALL PARTS WITH DETERGENT TO REMOVE CUTTING OILS AND RINSE WITH DE-IONIZED WATER.

5. PART SHALL BE PACKAGED IN A WAY TO PROTECT ALL SURFACES AND TO STOP CONTAMINATION FROM

ENTERING VACUUM VOLUME. SEALING ITEMS IN A POLYETHYLENE BAG IS PREFERRED.

SEE DETAIL A 2X

1/4-20 UNC - 2B TAP ↧ 0.48

#7 DRILL ( 0.201 ) ↧ 0.603

4X

8-32 UNC - 2B TAP ↧ 0.6

#29 DRILL ( 0.136 ) ↧ 0.7 -( 4 ) HOLES

2X

1/4-20 UNC - 2B TAP ↧ 0.482

#7 DRILL ( 0.201 ) ↧ 1

DETAIL A

SCALE 3:1

2X

1/4-20 UNC - 2B TAP ↧ 0.482

#7 DRILL ( 0.201 ) ↧ 0.603

4X

8-32 UNC - 2B TAP ↧ 0.6

#29 DRILL ( 0.136 ) ↧ 0.7 -( 4 ) HOLES

2X

1/4-20 UNC - 2B TAP ↧ 0.48

#7 DRILL ( 0.201 ) ↧ 0.603

4 3 2 1

A

C

D

4 3 2 1

A

B

C

D

B

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/29/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0026

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

V-CAVITY & MAGNETIC HOUSING LIFTING BLOCK

DRAWING NUMBER REV

CG2-M-20-U-0022 0

SIZE SCALE WEIGHT SHEET

C 2/1 1 LB 1 of 1

SPECIFICATIONMATERIAL

A36STEEL

TAP DRILL THRU

3/8-16 UNC-2B THRU

A

C

D

A

B

C

D

B

( )0.8

( )2.62

( )59.3

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/22/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0018

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

V-CAVITY MAGNETIC CASING MAGNET ASSEMBLY

DRAWING NUMBER REV

CG2-M-20-U-0023 0

SIZE SCALE WEIGHT SHEET

D 3:10 12 LB 1 of 1VENDOR

MATERIAL

SPECIFICATION

DESCRIPTION PART NUMBER QTY

FIND

NO.

ALUMINUM

V-CAVITY ALUMINUM WALL FOR MAGNETIC CASING CG2-M-20-U-0019 1 1

K&J MAGNETICS INC.

https://www.kjmagnetics.com/

NEODYMIUM

NEODYMIUM BLOCK MAGNET - 1/2" LEN X 1/4" WID X 1/2" THI B84Y0 99 2

AL 6061 (A96061)

Temporary Plates for Magnetic Casing Steel Wall CG2-M-20-U-0025 2 3

MCMASTER-CARR

https://www.mcmaster.com/

Thumb Screw, SS, 1/4"-20, 1/2" Long 91746A421 4 4

NOTES:

1. VENDORS AND VENDOR SPECIFIC ITEMS MAY NOT BE SUBSTITUTED WITHOUT PRIOR ENGINEERING APPROVAL.

2. CAUTION: HANDLING OF NEODYMIUM MAGNETS CAN CAUSE INJURY, REVIEW SAFETY DATA SHEET

AND ENSURE APPROPRIATE CONTROL OF HAZARDS ARE IN PLACE PRIOR TO HANDLING.

A

C

D

A

B

C

D

B

0.25

2.66

7.28

11.64

12.22

23.37

23.95

29.53

35.1

35.69

46.83

47.42

51.77

56.4

58.81

59.06

2X 0.75

0.38

3.49

0.03

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/27/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0026

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

STEEL WALL FOR MAGNETIC CASING

DRAWING NUMBER REV

CG2-M-20-U-0024 0

SIZE SCALE WEIGHT SHEET

D 1/4 21 LB 1 of 1

SPECIFICATIONMATERIAL

A36 (K02600)STEEL

NOTES:

1. METAL STAMP OR ETCH " CG2-M-20-U-0024 " IN 1/4 INCH MINIMUM HIGH LETTERS IN AREA SHOWN.

2. REMOVE ALL CONTAMINATION E.G. SCALE, DIRT, GREASE AND OIL PRIOR TO FABRICATION BY WIPING

MATERIAL DOWN WITH A CLEAN CLOTH OR PAPER TOWEL.

3. USE ONLY WATER SOLUBLE, NON-SULFUROUS BEARING CUTTING OILS FOR MACHINING.

4. WASH ALL PARTS WITH DETERGENT TO REMOVE CUTTING OILS AND RINSE WITH DE-IONIZED WATER.

5. THIS ASSEMBLY SHALL BE ELECTROLESS NICKEL COATED IN ACCORDANCE WITH ASTM B733. THE COATING THICKNESS SHALL BE .001 INCHES CLASSIFICATION: SC3 (MODERATE SERVICE), TYPE1, POST HEAT TREATMENT CLASS 1. THE COATING SHALL COVER ALL EXPOSED AREAS. ALL THREADED AND MACHINED HOLES SHALL BE MASKED TO PREVENT COATING MATERIAL FROM IMPINGING UPON MACHINED AREAS.

SEE DETAIL B

DETAIL B

SCALE 1/2

SCALE 1/1

C

D

4 3 2 1

A

B

C

D

B

.13

.75

59.06

2X .352X

.25

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/22/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0023

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

Temporary Plates for Magnetic Casing Steel Wall

DRAWING NUMBER REV

CG2-M-20-U-0025 0

SIZE SCALE WEIGHT SHEET

C 3/16 1 LB 1 of 1

SPECIFICATIONMATERIAL

---AL 6061 (A96061)

2X

1/4-20 UNC - 2B CLEAR

F DRILL ( .257 ) THRU

A

C

D

A

B

C

D

B

( )15.38

( )41.68

( )59.06

( ).79

( )3.49( )1.37

8.0.19

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/22/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0018

ANGULAR �#�.5

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: .06 MAX

SURFACE

ROUGHNESS: 125 RMS U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

V-CAVITY CASING STEEL WALL & LIFTING BLOCK ASSEMBLY

DRAWING NUMBER REV

CG2-M-20-U-0026 0

SIZE SCALE WEIGHT SHEET

D 1:4 23 LB 1 of 1VENDOR

MATERIAL

SPECIFICATION

DESCRIPTION PART NUMBER QTY

FIND

NO.

STEEL

A36 (K02600)

STEEL WALL FOR MAGNETIC CASING CG2-M-20-U-0024 1 1

STEEL

A36

V-CAVITY & MAGNETIC HOUSING LIFTING BLOCK CG2-M-20-U-0022 2 2

NOTES:

1 VENDORS AND VENDOR SPECIFIC ITEMS MAY NOT BE SUBSTITUTED WITHOUT PRIOR ENGINEERING

APPROVAL.

2. THIS ASSEMBLY SHALL BE ELECTROLESS NICKEL COATED IN ACCORDANCE WITH ASTM B733. THE COATING THICKNESS SHALL BE .001 INCHES CLASSIFICATION: SC3 (MODERATE SERVICE), TYPE 1, POST HEAT TREATMENT CLASS 1. THE COATING SHALL COVER ALL EXPOSED AREAS. ALL THREADED AND MACHINED HOLES SHALL BE MASKED TO PREVENT COATING MATERIAL FROM IMPINGING UPON MACHINED

AREAS.

3 WELD ITEM 2 TO 1 PRIOR TO COATING IN NICKEL.

4. PRIOR TO WELDING AND ELECTROLESS NICKEL COATING CLEAN THE PARTS WITH A MILD DETERGENT AND RINSE WITH DEIONIZED WATER. WIPE SURFACES WITH ISOPROPYL ALCOHOL AND ALLOW TO AIR DRY.

5. ASSEMBLY SHALL BE PACKAGED IN A WAY TO PROTECT ALL SURFACES AND TO STOP CONTAMINATION

FROM ENTERING VACUUM VOLUME. SEALING ITEMS IN A POLYETHYLENE BAG IS PREFERRED.

C

D

4 3 2 1

A

B

C

D

B

10 2

7.28

29.53

51.77

59.06

0.06

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/27/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0018

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: 1.5 MAX

SURFACE

ROUGHNESS: 3.2 Ra U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

BORATED ALUMINUM FOR V-CAVITY SHIELDING STEEL WALL SIDE

DRAWING NUMBER REV

CG2-M-20-U-0029 0

SIZE SCALE WEIGHT SHEET

C 1:5 0 LB 1 of 1

SPECIFICATIONMATERIAL

---AL EN6061 31% BORON-10

NOTES:

1. MATERIAL MUST BE BORAL FROM ALUMECO WITH 31% BORON AND A MINIMUM OF 1 MM THICKNESS

3X

TAP DRILL THRU

5/8-11 UNC-2B

C

D

4 3 2 1

A

B

C

D

B

12.81

46.25

59.06

0 1

0.06

NO REPRESENTATION OR WARRANTY, EXPRESSED OR IMPLIED, IS MADE AS TO THE ACCURACY, COMPLETENESS OR USEFULNESS OF THE INFORMATION OR STATEMENTS CONTAINED IN THESE DRAWINGS, OR THAT THE DISCLOSURE OF ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS MAY NOT INFRINGE PRIVATE RIGHTS OF OTHERS. NO LIABILITY IS ASSUMED

WITH RESPECT TO THE USE OF, OR FOR DAMAGES RESULTING FROM THE USE OF, ANY INFORMATION, APPARATUS, METHOD OR PROCESS DISCLOSED IN THESE DRAWINGS. DRAWINGS MADE AVAILABLE FOR INFORMATION TO BIDDER ARE NOT TO BE USED FOR OTHER PURPOSES AND ARE TO BE RETURNED UPON REQUEST OF THE FORWARDING CONTRACTOR.

REV DESCRIPTION OF CHANGE DES CHK ENG AP1 AP2 AP3 DATE

0 ORIGINAL ISSUE PER DCN CG2-DCN-00-0006 10/27/2025

NEXT USED ASSEMBLY

CG2-M-20-U-0018

ANGULAR �#�.5�$�

BREAK ALL SHARP EDGES

EXCEPT AS NOTED: 1.5 MAX

SURFACE

ROUGHNESS: 3.2 Ra U.N.O.

DRAFTING STD: ASME Y14.100

GDT: ASME Y14.5

WELD SYMBOLS: AWS A2.4

THIRD

ANGLE

PROJECTION

HFIR INSTRUMENT CG-2 GP-SANS

20 - OPTICAL

BORATED ALUMINUM FOR V-CAVITY SHIELDING ALUMINUM WALL SIDE

DRAWING NUMBER REV

CG2-M-20-U-0030 0

SIZE SCALE WEIGHT SHEET

C 3/16 0 LB 1 of 1

SPECIFICATIONMATERIAL

---AL EN6061 31% BORON-10

NOTES:

1. MATERIAL MUST BE BORAL FROM ALUMECO WITH 31% BORON AND A MINIMUM OF 1 MM THICKNESS

Sheet 1
Views
FRONT
TOP
DWG_ISO
Zones
D8
D7
D6
D5
D4
D3
D2
D1
C8
C7
C6
C5
C4
C3
C2
C1
B8
B7
B6
B5
B4
B3
B2
B1
A8
A7
A6
A5
A4
A3
A2
A1
CG2-M-20-U-0030-R00.pdf
Sheet 1
Views
FRONT
TOP
DWG_ISO
Zones
D4
D3
D2
D1
C4
C3
C2
C1
B4
B3
B2
B1
A4
A3
A2
A1
CG2-M-20-U-0029-R00.pdf
Sheet 1
Views
FRONT
TOP
DWG_ISO
Zones
D4
D3
D2
D1
C4
C3
C2
C1
B4
B3
B2
B1
A4
A3
A2
A1
CG2-M-20-U-0026-R00.pdf
Sheet 1
Views
FRONT
RIGHT
DWG_ISO
Zones
D8
D7
D6
D5
D4
D3
D2
D1
C8
C7
C6
C5
C4
C3
C2
C1
B8
B7
B6
B5
B4
B3
B2
B1
A8
A7
A6
A5
A4
A3
A2
A1
CG2-M-20-U-0025-R00.pdf
Sheet 1
Views
FRONT
TOP
DWG_ISO
Zones
D4
D3
D2
D1
C4
C3
C2
C1
B4
B3
B2
B1
A4
A3
A2
A1
CG2-M-20-U-0024-R00.pdf
Sheet 1
Views
new_view_4
new_view_5
B
new_view_13
Zones
D8
D7
D6
D5
D4
D3
D2
D1
C8
C7
C6
C5
C4
C3
C2
C1
B8
B7
B6
B5
B4
B3
B2
B1
A8
A7
A6
A5
A4
A3
A2
A1
CG2-M-20-U-0023-R00.pdf
Sheet 1
Views
FRONT
TOP
Explode
Zones
D8
D7
D6
D5
D4
D3
D2
D1
C8
C7
C6
C5
C4
C3
C2
C1
B8
B7
B6
B5
B4
B3
B2
B1
A8
A7
A6
A5
A4
A3
A2
A1
CG2-M-20-U-0022-R00.pdf
Sheet 1
Views
FRONT
TOP
new_view_4
Zones
D4
D3
D2
D1
C4
C3
C2
C1
B4
B3
B2
B1
A4
A3
A2
A1
CG2-M-20-U-0019-R00.pdf
Sheet 1
Views
FRONT
BOTTOM
new_view_5
A
BACK
Zones
D8
D7
D6
D5
D4
D3
D2
D1
C8
C7
C6
C5
C4
C3
C2
C1
B8
B7
B6
B5
B4
B3
B2
B1
A8
A7
A6
A5
A4
A3
A2
A1

File details come from the government source that posted it. Updated .