Plans 23158.pdf
PDF 12 MB Posted
- Solicitation number
- RFQ 171 260000000476 1
- Issued by
- Michigan
About this file
This is a design and construction plan document prepared by Matrix Pettitt Mann Straub Consulting Engineers for the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division for the Carson City Correctional Facility. The project involves the replacement and upgrade of cell door locks, controls, and related hardware systems across three buildings (Buildings 200, 500, and 1200) at the facility. The work includes demolition of existing door controllers, motors, switches, hangers, tracks, lock rails, guides, and receiving rails; installation of new electro-mechanical door hardware and control systems; removal and repurposing of 43 left and 43 right sliding cell doors from Standish Correctional Facility for use at Carson City, along with installation of additional new doors for Americans with Disabilities Act-compliant cells; and construction of temporary removable wall systems to maintain security and separation during the work while cells remain occupied. The project is organized into a base bid for Buildings 500 and 1200, with Alternate No. 1 deleting work for Building 1200 and Alternate No. 2 addressing Building 200 segregation work. Door replacement will be performed in groups of four doors at a time for Buildings 500 and 1200, and groups of two doors for Building 200, with work sequenced to allow manual operation by local key during construction phases. The plans indicate a release date for bids of September 24, 2026.
The specifications require coordination with existing AIM electro-mechanical locks and hardware systems, with field verification of all existing controls and wiring mandated throughout the project. Construction work includes temporary wall system installation using either a STARC Lightbarrier demountable partition system or an alternative 3/4-inch non-compliant plywood on 2.5-inch metal studs configuration, both with fire-rated seals and smoke barriers. The project involves installation of new programmable logic controller (PLC) systems, ethernet switches, human-machine interfaces (HMI) for door control, and integration with the facility's StarNet 21 control system. Paint touch-up on walls damaged during construction and painting of new doors and frames are included in the scope. The facility has indicated that inmate cells will remain occupied throughout the construction period except for those undergoing active work, requiring careful sequencing and temporary separation measures to maintain security protocols.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Mich Spec 23158.pdf | ||
| LEIN Request 23158.pdf | ||
| Advertisement 23158.pdf | ||
| Service Disabled Veteran Owned Business Info Sheet 2025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KPM
JFS
472/23158.TYC
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
N/A consultant job no.
23545.00 sheet title
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
T1.1
TITLE PAGE
9/25/2026 BID SET
91120
190 191
187 185
184 179 180 181
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
SHOWERS
LAUNDRY
OFFICE
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
SHOWERS
OFFICE
STORAGE
OFFICE
STORAGE
STORAGE
181STAFF
MECHANICAL
ROOM
ELECTRICAL
ROOM
DAYROOM
TV ROOM
DAYROOM
STAIRWELL STAIRWELL
A2.1
DEMOUNTABLE
PARTITION
LOCATIONS,
TYP.
TYP.
VENDING
COMMAND
CENTER
176 177
VESTIBULEA2.1
OPP.
HAND
A2.1
A2.1
A2.1
OPP.
HAND
120 11
17054
79A
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
SHOWERS SHOWERS
STAIRWELL STAIRWELL
DEMOUNTABLE
PARTITION
LOCATIONS,
TYP.
A2.1
TYP.
HC
HC
HC
HC
HC
HC
HC
HC
HC
HC
A2.1
A2.1
OPP.
HAND
'-8
" F
IE
LD
V
ER
IF
Y
10"±
1'- 2"
1'-
2"
± EXISTING STEEL
SPRINKLER PIPE
HOUSING
EXISTING FLOOR
EXISTING CONCRETE SLAB
EX. REMOVABLE
STEEL PLATES
1'-6"±
DEMOUNTABLE
TEMPORARY
PANEL SYSTEM
'-0
REUSABLE FILLER
PANEL AS PART OF
THE DEMOUNTABLE
PANEL SYSTEM
INFILL TRIMMED FOR
ACOUSTIC TILE DROP.
TYPICAL HC INMATE CELL TYPICAL INMATE CELL
PLUMBING CHASE
DEMOUNTABLE TEMPORARY WALL
PANELS AND DOOR. SMOKE BARRIER.
EXISTING MASONRY WALLS
REMOVE LIGHT FIXTURE FOR
INSTALLATION OF TEMPORARY
DEMOUNTABLE PARTITION IF
NECESSARY FOR CLEARANCE.
REINSTALL AFTER REMOVAL OF
PARTITION, TYPICAL.LOCKABLE DOOR, PART OF
DEMOUNTABLE PARTITION
SYSTEM. ALT. TEMPORARY
H.M. DOOR AND FRAME.
EXISTING DOOR OPERATOR CHASE
EXISTING CONDUIT AND SPRINKLER PIPE
CHASE
TYPICAL HC INMATE CELLTYPICAL INMATE CELL
PLUMBING CHASE
EXISTING DOOR OPERATOR CHASE
EXISTING MASONRY WALLS
BUILDING 500 MAIN & UPPER LEVEL
SCALE: 1/8" = 1'-0"
4' 8'0 16'
BUILDING 500 LOWER LEVEL
A1.1
BASE BID
BASE BID
BUILDING 500 FLOOR
PLANS
1. CELLS WITHIN THE HOUSING UNIT, EXCEPT FOR THOSE BEING WORKED ON, WILL REMAIN OCCUPIED DURING THE
CONSTRUCTION TIME PERIOD .
2. DOOR OPERATOR, LOCK RAIL, GUIDE, AND RECEIVER REPLACEMENT WILL BE DONE IN GROUPS OF FOUR DOORS
(FOUR DOORS AT A TIME) .
3. A TEMPORARY WALL SHALL BE CONSTRUCTED TO SEPARATE THE DOORS FROM THE REMAINING OCCUPIED WING.
SEE DETAILS 1 AND 2 ON THIS SHEET FOR A LAYOUT OF PREMANUFACTURED REMOVABLE WALL SYSTEM .
4. SEQUENCE OF WORK:
a. ERECT TEMPORARY REMOVABLE PARTITION AT DOORS .
b. DEMOLISH EXISTING DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDE, RECEIVING
RAIL AND DOORS. EXISTING DOOR CONTROL HOUSING TO REMAIN .
c. INSTALL NEW DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDES, RECEIVING RAIL
AND REPLACEMENT DOORS. CONNECT EXISTING CONTROL CABLING TO THE NEW CONTROL BOARDS AND
SWITCHES .
d. CLEAN AND CLEAR CONSTRUCT SPACE OF TOOLS, MATERIALS ETC. REMOVE TEMPORARY WALL. REPEAT
SEQUENCE UNTIL ALL DOORS ARE COMPLETE .
5. DURING WORK ON CELL DOORS, THE BANK OF DOORS BEING WORKED ON WILL ONLY HAVE MANUAL OPERATION
INCLUDING LOCK/UNLOCK FUNCTION BY LOCAL KEY.
6. EXISTING DOOR HARDWARE: LOCKS FOR SWING DOORS ARE AIM ELECTRO-MECHANICAL LOCKS. EXISTING SLIDING
DOOR HARDWARE IS ASSUMED TO BE AIM AS WELL .
7. TOUCH UP PAINT ON WALLS DAMAGED DURING CONSTRUCTION PAINT NEW DOORS AND FRAMES.
8. REMOVE 43 LEFT SLIDING AND 43 RIGHT SLIDING CELL DOORS FROM STANDISH CORRECTIONAL . CLEAN, MODIFY
AND INSTALL NEW DOORS AT CELLS AT CARSON CITY.
9. FURNISH AND INSTALL 5 LEFT SLIDING AND 5 RIGHT SLIDING DOORS TO COVER 2'-8" WIDE OPENING AT
HANDICAP/BARRIER FREE CELLS. DOORS NOTED *, ALSO FIELD VERIFY.
NOTES:
DEMOUNTABLE PARTITION SYSTEM:
BASIS OF DESIGN - STARC LIGHTBARRIER SYSTEM;
CLASS A SMOKE AND FIRE SPREAD; COMPATIBLE
FILLER PANELS AND DOOR PANEL WITH SMOKE SEALS.
ALTERNATE TO DEMOUNTABLE PARTITION SYSTEM:
4" NON-COM PLYWOOD ON 21
2" METAL STUDS; FIRE
TAPED AND SEALED EACH SIDE; HOLLOW METAL DOOR
AND FRAME WITH SMOKE SEALS.
NOTE:
1. IN SEVERAL LOCATIONS OF EACH WING, A 3 4" IS
LOCATIED AGAINST THE CEILING. THIS CONDUIT
WILL NEED TO REMAIN. INFILL DEMOUNTABLE
PARTITION EACH SIDE OF EXISTING CONDUIT TO
MAINTAIN SEAL AGAINST THE EXISTING CEILING
TILE.
2. EXISTING CEILING TILE IS ADHERED TO THE
UNDERSIDE OF THE CONCRETE SLAB ABOVE.
APPROXIMATELY 12" OF CONCRETE SLAB IS
EXPOSED BETWEEN CEILING TILE AND SPRINKLER
CHASE.
TYPICAL TEMPORARY WALL SECTION
SCALE: 3/4" = 1'-0"A1.1
TYPICAL TEMPORARY WALL PLAN
SCALE: 1/4" = 1'-0"A1.1
M a t r ix
P L
U R
I B
U E
S U
N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
RO
AD
9/24/2026 RELEASED FOR BIDS
RM
SR
AutoCAD SHX Text
472/23158.TYC
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text sheet no.
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472DRFmaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 23545
AutoCAD SHX Text sheet title
AutoCAD SHX Text
10274 BOYER ROAD
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
544 CHERBOURG DR.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CARSON CITY CORRECTIONAL FACILITY
AutoCAD SHX Text 23545.00
AutoCAD SHX Text
CELL DOOR LOCKS & CONTROLS
AutoCAD SHX Text
AutoCAD SHX Text
CARSON CITY, MI 48811
120 91
187 185
184 179 180 181
144 170
191190
STAIRWELL STAIRWELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
LAUNDRY
OFFICE
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
SHOWERS SHOWERS
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
STORAGE
OFFICE
OFFICE
STORAGE
VESTIBULE VESTIBULE
STORAGE
181STAFF
MECHANICAL
ROOM
ELECTRICAL
ROOM
DAYROOM
TV ROOM
DAYROOM
COMMAND
CENTER
DEMOUNTABLE
PARTITION
LOCATIONS,
TYP.
VENDING
176 177
VESTIBULEA2.1
OPP.
HAND
A2.1
A2.1
A2.1
OPP.
HAND
11120
17054
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
SHOWERS SHOWERS
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
STAIRWELL STAIRWELL
DEMOUNTABLE
PARTITION
LOCATIONS,
TYP.
A2.1
A2.1
OPP.
HAND
BUILDING 1200 MAIN & UPPER LEVEL
SCALE: 1/8" = 1'-0"
4' 8'0 16'
BUILDING 1200 LOWER LEVEL
A1.2
ALTERNATE NO.1- DELETE WORK THIS SHEET
BASE BID
BUILDING 1200 FLOOR
PLANS
NOTES:
M a t r ix
P L
U R
I B
U E
S U
N U M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
R
OA
D
1. CELLS WITHIN THE HOUSING UNIT, EXCEPT FOR THOSE BEING WORKED ON, WILL REMAIN OCCUPIED DURING THE
CONSTRUCTION TIME PERIOD .
2. DOOR OPERATOR, LOCK RAIL, GUIDE, AND RECEIVER REPLACEMENT WILL BE DONE IN GROUPS OF FOUR DOORS
(FOUR DOORS AT A TIME)
3. A TEMPORARY WALL SHALL BE CONSTRUCTED TO SEPARATE THE DOORS FROM THE REMAINING OCCUPIED WING.
SEE DETAILS 1 AND 2 ON THIS SHEET FOR A LAYOUT OF PREMANUFACTURED REMOVABLE WALL SYSTEM .
4. SEQUENCE OF WORK:
a. ERECT TEMPORARY REMOVABLE PARTITION AT DOORS.
b. DEMOLISH EXISTING DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDE, RECEIVING
RAIL AND DOORS. EXISTING DOOR CONTROL HOUSING TO REMAIN .
c. INSTALL NEW DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDES, RECEIVING RAIL
AND REPLACEMENT DOORS. CONNECT EXISTING CONTROL CABLING TO THE NEW CONTROL BOARDS AND
SWITCHES .
d. CLEAN AND CLEAR CONSTRUCT SPACE OF TOOLS, MATERIALS ETC. REMOVE TEMPORARY WALL. REPEAT
SEQUENCE UNTIL ALL DOORS ARE COMPLETE .
5. DURING WORK ON CELL DOORS, THE BANK OF DOORS BEING WORKED ON WILL ONLY HAVE MANUAL OPERATION
INCLUDING LOCK/UNLOCK FUNCTION BY LOCAL KEY.
6. EXISTING DOOR HARDWARE: LOCKS FOR SWING DOORS ARE AIM ELECTRO-MECHANICAL LOCKS. EXISTING SLIDING
DOOR HARDWARE IS ASSUMED TO BE FOLGER ADAM .
7. TOUCH UP PAINT ON WALLS DAMAGED DURING CONSTRUCTION PAINT NEW DOORS AND FRAMES.
8. REMOVE 48 LEFT SLIDING AND 48 RIGHT SLIDING CELL DOORS FROM STANDISH CORRECTIONAL . CLEAN MODIFY, AND INSTALL NEW DOORS AT CELLS AT CARSON CITY.
9/24/2026 RELEASED FOR BIDS
RM
SR
AutoCAD SHX Text
472/23158.TYC
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text sheet no.
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472DRFmaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 23545
AutoCAD SHX Text sheet title
AutoCAD SHX Text
10274 BOYER ROAD
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
544 CHERBOURG DR.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CARSON CITY CORRECTIONAL FACILITY
AutoCAD SHX Text 23545.00
AutoCAD SHX Text
CELL DOOR LOCKS & CONTROLS
AutoCAD SHX Text
10" 4'-10"±
3'-6"
13'-4"±
3'-6"
6'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10"
'-0
3' -6
'-0
2' -0
2'
-0
2' -0
4' -0
'-0
3' -6
4'-10"±
7'-6"
6"
21'-0"
6"
3'-6"
6"
6'-0" 6" 12'-0"
6"
6'-0"
6"
10'-0"
6"
8'-0"
5' -0
2' -0
16'-8"
11' -4
'-0
'-6
11' -4
7'- 7"
7'- 7"
5' -2
7'- 7"
7'- 7"
11'-4"
'-0
8"
8'-8"
169'-8"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
10'-0"
2'-0"
2'-0"
2'-0"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6"
7'-7"
6'-0"
4'-8"±
4' -0
5' -2
73'-10"
5'-3"±
8"
5'-9"
4' -0
7'-7"
6"
7'-7"
8"
3'-7" 59'-10"
6"11'-4"
8"
6"
8"
4'-2"±
CELL
CELL
CELL
CELL
CELL
CELL
HC
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
HC
CELL
59*
6" 8'-0"
6"
10'-0"
6"
7'-
A2.2
1,2
SIM
BUILDING 200 SEGREGATION
SCALE: 1/8" = 1'-0"
4' 8'0 16'
A1.3
ALTERNATE NO. 2 - DELETE WORK THIS SHEET
BUILDING 200 FLOOR
PLAN
M a t r ix
P L
U R
I B
U E
S U
N U M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
R
OA
D
1. CELLS WITHIN THE HOUSING UNIT, EXCEPT FOR THOSE BEING WORKED ON, WILL REMAIN OCCUPIED DURING THE
CONSTRUCTION TIME PERIOD .
2. DOOR OPERATOR, LOCK RAIL, GUIDE, AND RECEIVER REPLACEMENT WILL BE DONE IN GROUPS OF TWO DOORS
(TWO DOORS AT A TIME) .
3. A TEMPORARY WALL SHALL BE CONSTRUCTED TO SEPARATE THE DOORS FROM THE REMAINING OCCUPIED WING.
SEE DETAILS 1 AND 2 ON A1.1 FOR A LAYOUT OF PREMANUFACTURED REMOVABLE WALL SYSTEM .
4. SEQUENCE OF WORK:
a. ERECT TEMPORARY REMOVABLE PARTITION AT DOORS .
b. DEMOLISH EXISTING DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDE, RECEIVING
RAIL AND DOORS. EXISTING DOOR CONTROL HOUSING TO REMAIN .
c. INSTALL NEW DOOR CONTROLLER, MOTOR, SWITCHES, HANGERS, TRACK, LOCK RAIL, GUIDES, RECEIVING RAIL
AND REPLACEMENT DOORS. CONNECT EXISTING CONTROL CABLING TO THE NEW CONTROL BOARDS AND
SWITCHES .
d. CLEAN AND CLEAR CONSTRUCT SPACE OF TOOLS, MATERIALS ETC. REMOVE TEMPORARY WALL. REPEAT
SEQUENCE UNTIL ALL DOORS ARE COMPLETE .
5. DURING WORK ON CELL DOORS, THE BANK OF DOORS BEING WORKED ON WILL ONLY HAVE MANUAL OPERATION
INCLUDING LOCK/UNLOCK FUNCTION BY LOCAL KEY.
6. EXISTING DOOR HARDWARE: LOCKS FOR SWING DOORS ARE AIM ELECTRO-MECHANICAL LOCKS. EXISTING SLIDING
DOOR HARDWARE IS ASSUMED TO BE AIM AS WELL .
7. TOUCH UP PAINT ON WALLS DAMAGED DURING CONSTRUCTION PAINT NEW DOORS AND FRAMES.
8. REMOVE 11 LEFT SLIDING (VERIFY IN FIELD) AND 9 RIGHT (VERIFY IN FIELD) SLIDING CELL DOORS FROM STANDISH
CORRECTIONAL . CLEAN, MODIFY AND INSTALL NEW DOORS AT CELLS AT CARSON CITY.
9. FURNISH AND INSTALL 2 RIGHT SLIDING DOORS (VERIFY IN FIELD) TO COVER 2'-8" WIDE OPENING AT
HANDICAP/BARRIER FREE CELLS. DOORS NOTED *, ALSO FIELD VERIFY.
NOTES:
9/24/2026 RELEASED FOR BIDS
RM
SR
AutoCAD SHX Text
472/23158.TYC
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text sheet no.
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472DRFmaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 23545
AutoCAD SHX Text sheet title
AutoCAD SHX Text
10274 BOYER ROAD
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
544 CHERBOURG DR.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CARSON CITY CORRECTIONAL FACILITY
AutoCAD SHX Text 23545.00
AutoCAD SHX Text
CELL DOOR LOCKS & CONTROLS
AutoCAD SHX Text
'-8
A2.1
REPLACE EXISTING MAG LOCKS
REPLACE EXISTING MAG LOCKS
CORRIDOR VESTIBULE
A2.1
1 ROTATED.
PATCH EXISTING CONCRETE
MASONRY AS NEEDED.
PATCH PAINT
PATCH EXISTING CONCRETE
MASONRY AS NEEDED.
PATCH PAINT
EXISTING DOOR AND
FRAME TO REMAIN
EXISTING DOOR AND
FRAME TO REMAIN
REMOVE & REPLACE
EXISTING DOOR FRAME,
AND HARDWARE
PAINT EXISTING DOOR
FRAME
A2.1
3'-4"
TYPICAL INMATE CELL
STAIRWELL REMOVE & REPLACE
EXISTING DOOR FRAME,
AND HARDWARE
A2.1
DUCT CHASE
PATCH EXISTING
CONCRETE
MASONRY AS
NEEDED. PATCH
PAINT
PAINT EXISTING DOOR
FRAME
'-0
" V .I.
F.
3'-0" 3'-0"
6'-8" ± V.I.F.
4" 2"2"
7'- 2"
KICKPLATE
PUSH BAR
2'-0"
3' -2
LAMINATE
POLYCARBONATE
GLAZING
BACK-TO-BACK
ELECTRO-MECH.
LOCKS
HOLLOW METAL
FRAME, GALV.
PRIMED AND PAINT
HOLLOW METAL
DOOR AND FRAME,
GALV.
PRIMED AND PAINT
EXISTING CONDUIT
IN WALL TO ABOVE
CEILING FOR DOOR
CONTROLS
A2.1
EXISTING LINTEL
TO REMAIN
'-0
" V .I.
F.
NEW ELECTRO-
MECHANICAL
LOCK
REPLACE
EXISTING
FIRE-RATED DOOR
AND FRAME3'
-3
'-8
EXISTING LINTEL TO
REMAIN
PATCH EXISTING
MASONRY AS NEEDED
PRIME AND PAINT
WALL
3'-0"
A2.1
1-1/2 HOUR FIRE-RATED
GLAZING
NEW HOLLOW METAL
DOOR AND FRAME
1-1/2 HR. RATED, GALV.
PRIMED AND PAINT
FACE OF MASONRY
WALL
3'-4"
3'-41
2"± FIELD VERIFY
F
IE
LD
V
ER
IF
Y
WALL AT FIRST FLOOR
CONTINUOUS
EPOXY SEALANT,
EACH SIDE
FRAME ANCHORS,
COUNTERSINK SCREWS,
BONDO OVER HEADS,
PAINT TO MATCH EXISTING
DOORS AND FRAMES
PAINT NEW HOLLOW METAL DOOR AND FRAME
STAINLESS STEEL PUSH BAR
ELECTRO-MECHANICAL DOOR LOCK
PULL EXISTING CABLES BACK FOR
FRAME REPLACEMENT, THEN CONNECT
TO NEW LOCK AFTER INSTALLATION.
NEW DOOR POSITION
SWITCH IN FRAME, RECONNECT
TO EXISTING CABLE.
GROUT FRAME SOLIDCYLINDER EXTENDER
GROUT FRAME
SOLID EXCEPT
AT LOCKSET
6'-81
2"± FIELD VERIFY
F
IE
LD
V
ER
IF
Y
CONTINUOUS
EPOXY SEALANT,
EACH SIDE
FRAME ANCHORS,
COUNTERSINK SCREWS,
BONDO OVER HEADS,
PAINT TO MATCH EXISTING
DOORS AND FRAMES
PAINT NEW HOLLOW METAL DOOR AND FRAME
STAINLESS STEEL PUSH BAR
NEW DOOR POSITION SWITCH
IN FRAME HEAD, RECONNECT
TO EXISTING CABLE.
ELECTRO-MECHANICAL DOOR LOCK
PULL EXISTING CABLES BACK FOR
FRAME REPLACEMENT, THEN CONNECT
TO NEW LOCK AFTER INSTALLATION.
4"
FASTEN A STEEL "U" PLATE TO
FLOOR AT MULLION LOCATION.
PLATE TO BE MINIMUM 12 GAUGE
GALVANIZED STEEL.
CYLINDER EXTENDERS AT
EACH LOCK
EXISTING MASONRY WALL
NEW DOOR POSITION SWITCH
IN FRAME HEAD, RECONNECT
TO EXISTING CABLE.
GROUT FRAME SOLIDGROUT MULLION SOLID
ABOVE AND BELOW
LOCKS
PATCH EXISTING
RESILIENT TILE AT
NEW FRAME
CORRIDOR
VESTIBULE
1-1/2 HOUR FIRE-RATED
GLAZING
LAMINATE
POLYCARBONATE
GLAZING
STAINLESS STEEL PULL
STAINLESS STEEL PULL
3'-4"
STAIRWELL
TYPICAL INMATE CELL
A2.1
A2.1
OPP. HAND
OPP. HAND
DUCT CHASE
PATCH EXISTING
CONCRETE MASONRY
AS NEEDED. PATCH
PAINT
REMOVE & REPLACE
EXISTING DOOR FRAME,
AND HARDWARE
PAINT EXISTING DOOR
FRAME
A2.2
1,2
TYPICAL HC INMATE CELL
TYPICAL INMATE CELL
PLUMBING CHASE
3' -0
2'
-1
A2.2
REMOVE AND REPLACE
EXISTING DOOR RECEIVER,
LOCKING COLUMN, DOOR
GUIDE, OPERATOR,
SWITCHES, TRACK &
ELECTRONICS
REMOVE AND REPLACE
EXISTING DOOR RECEIVER,
LOCKING COLUMN, DOOR
GUIDE, OPERATOR,
SWITCHES, TRACK &
ELECTRONICS
PAINT NEW DOOR
RECEIVERS, LOCKING
COLUMNS, DOOR GUIDES,
OPERATORS & TRACKS
A2.2
DOOR SCHEDULE
DOOR NUMBERS DOOR SIZE DOOR TYPE DOOR MAT'L FRAME TYPE FRAME MAT'L FRAME DETAILS HARDWARE SET REMARKS
2'-10" x 6'-8"
EXISTING
HOLLOW
METAL
EXISTING
TO REMAIN
BUILDING 500
42, 44, 46, 48, 50, 55, 57, 59, 61, 63 3'-0" x 6'-8"
BUILDING 500
1-24; 41, 43,45,47,49;
51-54; 56, 58, 60, 62, 64; 81-104; 131-154
SET 3
SET 3
SET 1BUILDING 500
176 & 177 3'-0" ± V.I.F x
7'-2"
REPURPOSED
NARROW
STEEL CORE
HALF LITE
STEEL CORE
HOLLOW
METAL
1/A2.1 3,4/A2.1
NARROW
STEEL CORE
1/A2.2 2/A2.2 3/A2.2 5A2.2
1/A2.2 2/A2.2 4/A2.2 6/A2.2
EXISTING DOORS INITIAL
FIELD MEASUREMENT
34 14" X 78 3 4"
EXISTING
HOLLOW
METAL
EXISTING
HOLLOW
METAL
EXISTING
HOLLOW
METAL
BUILDING 200
42-50, 57, 58, 60-68
ALTERNATE NO. 1
2'-10" x 6'-8"
EXISTING
HOLLOW
METAL
EXISTING
TO REMAIN
REPURPOSED
NARROW
STEEL CORE
1/A2.2 SIM
2/A2.2 SIM
3/A2.2 SIM
5A2.2 SIM
EXISTING
HOLLOW
METAL
ALTERNATE NO. 1
SET 3
SET 3BUILDING 200
51 & 59
3'-0" x 6'-8"
NARROW
STEEL CORE
1/A2.2 SIM
2/A2.2 SIM
4/A2.2 SIM
6/A2.2 SIM
EXISTING
HOLLOW
METAL
EXISTING
HOLLOW
METAL
BUILDING 500
39, 79, 119, 169
3'-0" x 6'-8"
SET 2 1-1/2" HR FIRE RATEDHOLLOW
METAL
2/A2.1 5,6/A2.1 7/A2.1
NARROW LITE
STEEL CORE
BUILDING 1200
1-24; 41-64; 81-104;
131-154
2'-10" x 6'-8"
EXISTING
HOLLOW
METAL
EXISTING
TO REMAIN
SET 3REPURPOSED
NARROW
STEEL CORE
1/A2.2 2/A2.2 3/A2.2 5A2.2
EXISTING DOORS INITIAL
FIELD MEASUREMENT
34 14" X 78 3 4"
BUILDING 1200
39, 79, 119, 169
3'-0" x 6'-8"
SET 2 1-1/2" HR FIRE RATEDHOLLOW
METAL
2/A2.1 5,6/A2.1 7/A2.1
NARROW LITE
STEEL CORE
SET 1BUILDING 1200
176 & 177 3'-0" ± V.I.F x
7'-2"
HALF LITE
STEEL CORE
HOLLOW
METAL
1/A2.1 3,4/A2.1
ALTERNATE NO. 2
ALTERNATE NO. 2
ALTERNATE NO. 2
A2.1
BUILDINGS 200, 500 &
1200 DOOR DETAILS,
ELEVATIONS & DOOR
SCHEDULE
STAIRWELL DOOR ELEVATION
SCALE: 1/2" = 1'-0"A2.1
UPPER FLOOR STAIRWELL DOOR PLAN
SCALE: 1/2" = 1'-0"A1.1/1.2
6LOWER FLOOR STAIRWELL DOOR PLAN
SCALE: 1/2" = 1'-0"A1.1/1.2
STAIRWELL DOOR DETAIL
SCALE: 1-1/2" = 1'-0"A2.1
FRONT ENTRANCE FLOOR PLAN
SCALE: 1/2" = 1'-0"A1.1/1.2
3 FRONT ENTRANCE FLOOR ELEVATION
SCALE: 1/2" = 1'-0"A2.1
ENTRANCE DOOR DETAIL
SCALE: 1-1/2" = 1'-0"A2.1
M a t r ix
P L
U R
I B
U E
S U
N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
RO
AD
INMATE CELL PLAN
SCALE: 1/2" = 1'-0"A1.1
9/24/2026 RELEASED FOR BIDS
RM
SR
AutoCAD SHX Text
472/23158.TYC
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text sheet no.
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472DRFmaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 23545
AutoCAD SHX Text sheet title
AutoCAD SHX Text
10274 BOYER ROAD
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
544 CHERBOURG DR.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CARSON CITY CORRECTIONAL FACILITY
AutoCAD SHX Text 23545.00
AutoCAD SHX Text
CELL DOOR LOCKS & CONTROLS
AutoCAD SHX Text
MASONRY WALL
EXISTING FRAME
LOCK COLUMN
NEW HOLLOW METAL
DOOR
'-8
NEW
SLIDING
SHUTTER
NEW GLAZING
1'- 1"
1'- 1"
10"±
EXISTING ENCLOSURE
TO REMAIN
EXISTING PLASTER
SOFFIT TO REMAIN
WHERE IT OCCURS
NEW BOTTOM
DOOR TRACK
NEW GUIDE RAIL
1" C
LE
A
R
2' -6
3'
-7
BOTTOM
FOOD SLOT
TOP FOOD
SLOT
SLAM LOCK
AND CYLINDER
SLAM LOCK
AND CYLINDER
TOP FOOD
SLOT FRAME
TOP FOOD
SLOT FRAME
2"
2' -1
3"
EXISTING FRAME
NEW BOTTOM DOOR GUIDE
REPURPOSED HOLLOW
METAL CELL DOOR
NEW LOCK COLUMN
NEW RECEIVER CHANNEL
A2.2
NEW JAMB
PAINT NEW DOOR RECEIVER,
LOCKING COLUMN, DOOR
GUIDE, OPERATOR & TRACK
NEW LOWER GUIDE RAIL
EXISTING FRAME
MASONRY
WALL
EXISTING FRAME
NEW LOCK COLUMN
REPURPOSED HOLLOW CELL
DOOR TO BE INSTALLED
'-8
1'- 1"
1'- 1"
10"±
EXISTING ENCLOSURE
TO REMAIN
REPLACE SCREWS WITH
NEW STAINLESS STEEL
SECURITY SCREWS
EXISTING PLASTER
SOFFIT TO REMAIN
2' -4
EXISTING SHUTTER TO REMAIN
CLEAN AND REPAIR AS NEEDED
REMOVE EXISTING FOOD.
INSTALL NEW FOOD SLOTS
3' -7
1" C
LE
A
R
NEW SLAM LOCK AND
CYLINDER
NEW SLAM LOCK AND
CYLINDER
'-8
3' -3
2'-4"2'-10"2'-8" 3'-0"±
'-8
NEW LOCKING COLUMN
NEW
RECEIVER
NEW
RECEIVER
EXISTING OPERATOR ENCLOSURE
EXISTING PIPE CHASE DOOR &
FRAME TO REMAIN
ADA CELL WITH NEW
DOOR
NON-ADA CELL WITH REPURPOSED
CELL DOOR
ADA CELL WITH NEW
DOOR
NON-ADA CELL WITH REPURPOSED
CELL DOOR
PAINT EXISTING CELL
DOOR FRAMESPAINT CELL DOORS
EXISTING PIPE CHASE DOOR &
FRAME TO REMAIN
REPURPOSED
CELL DOOR
REMOVE
EXISTING FOOD
SLOTS. INSTALL
NEW FOOD
SLOTS.
1'-4"
2' -6
3' -7
1'-5"
A2.2
A2.2
A2.2
2"
3'
-0
3"
NEW RECEIVER CHANNEL
NEW JAMB
EXISTING FRAME
PAINT NEW DOOR RECEIVER,
LOCKING COLUMN, DOOR
GUIDE, OPERATOR & TRACK
EXISTING FRAME
NEW BOTTOM DOOR GUIDE
REPURPOSED HOLLOW
METAL CELL DOOR
NEW LOCK COLUMN
NEW SLIDING SHUTTER
NEW GLAZING
A2.2
BUILDINGS 200, 500 &
1200 DOOR DETAILS
NEW ADA CELL DOOR SECTION
SCALE: 3" = 1'-0"A2.2
REPURPOSED CELL DOOR PLAN
SCALE: 3" = 1'-0"A2.1
REPURPOSED CELL DOOR SECTION
SCALE: 3" = 1'-0"A2.2
M a t r ix
P L
U R
I B
U E
S U
N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I
S P
E N
I N
S U
L A
M A
M
OE
N A
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
RO
AD
NEW OPERATIONAL
TRACK & ELECTRONICS
CELL DOOR ELEVATION
SCALE: 1/2" = 1'-0"A2.1
1 CELL DOOR ELEVATION WITHOUT DOORS
SCALE: 1/2" = 1'-0"A2.1
NEW ADA CELL DOOR PLAN
SCALE: 3" = 1'-0"A2.1
9/24/2026 RELEASED FOR BIDS
RM
SR
AutoCAD SHX Text
472/23158.TYC
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text sheet no.
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472DRFmaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 23545
AutoCAD SHX Text sheet title
AutoCAD SHX Text
10274 BOYER ROAD
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48917
AutoCAD SHX Text
544 CHERBOURG DR.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CARSON CITY CORRECTIONAL FACILITY
AutoCAD SHX Text 23545.00
AutoCAD SHX Text
CELL DOOR LOCKS & CONTROLS
AutoCAD SHX Text
M a t r ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
RO
AD
M a t r ix
A1 A2
C
B1 B2
1 1
DC
DC DC
DC DC
DCDC
DC
DM DM
DCDCDC
DM
DM
DM
DC
DC
DM
DM
DC
DC
KEYED NOTES
REPORTS TO CONTROL CENTER VIA STARNET21
NEW FRAME; REFER TO DOOR SCHEDULE2 LEGEND
DM
DC
DOOR WITH
STATUS
DOOR WITH
LOCK AND STATUS
NOTES
1. ALL INMATE CELLS HAVE SLIDING DOORS WHICH REQUIRE
AN OPEN AND CLOSE SIGNAL, HAVE A DOOR STATUS, HAVE AN
INMATE CALL BUTTON, AND HAVE A CONSTANT HOT
KEYSWITCH.
2. FIELD VERIFY ALL EXISTING CONTROLS AND WIRING
TE1.1
BUILDING 500
BASE BID CONTROLS
CELL1
CELL2
CELL3
CELL4
CELL5
CELL6
CELL7
CELL8
CELL9
CELL10
CELL11
CELL12
CELL13
CELL14
CELL15
CELL16
CELL17
CELL18
CELL19
CELL20
CELL21
CELL22
CELL23
CELL24
CELL81
CELL82
CELL83
CELL84
CELL85
CELL86
CELL87
CELL88
CELL89
CELL90
CELL91
CELL92
CELL93
CELL94
CELL95
CELL96
CELL97
CELL98
CELL99
CELL100
CELL101
CELL102
CELL103
CELL104
SHOWERS SHOWERS
SHOWERSSHOWERS
OFFICE OFFICE
STORAGE STORAGE
VENDINGLAUNDRY OFFICE
COMMAND
CENTER
DAYROOM DAYROOM DAYROOM ELECTRICAL MECHANICAL
STAFF
STORAGE
CE
LL
CE
LL
CE
LL
IN
MAT
E
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
175 176 187 185 184
177 178
190 191 t r ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
R
OA
D
A1 A2
C
B1 B2
1 1
2 2
DC
DC DC
DC DC
DCDC
DC
DM DM
DCDCDC
DM
DM
DM
DC
DC
DM
DC
DC
KEYED NOTES
REPORTS TO CONTROL CENTER VIA STARNET21
NEW FRAME; REFER TO DOOR SCHEDULE2 LEGEND
DM
DC
DOOR WITH
STATUS
DOOR WITH
LOCK AND STATUS
NOTES
1. ALL INMATE CELLS HAVE SLIDING DOORS WHICH REQUIRE
AN OPEN AND CLOSE SIGNAL, HAVE A DOOR STATUS, HAVE AN
INMATE CALL BUTTON, AND HAVE A CONSTANT HOT
KEYSWITCH.
2. FIELD VERIFY ALL EXISTING CONTROLS AND WIRING
TE1.2
BUILDING 1200
BASE BID CONTROLS
CELL1
CELL2
CELL3
CELL4
CELL5
CELL6
CELL7
CELL8
CELL9
CELL10
CELL11
CELL12
CELL13
CELL14
CELL15
CELL16
CELL17
CELL18
CELL19
CELL20
CELL21
CELL22
CELL23
CELL24
CELL81
CELL82
CELL83
CELL84
CELL85
CELL86
CELL87
CELL88
CELL89
CELL90
CELL91
CELL92
CELL93
CELL94
CELL95
CELL96
CELL97
CELL98
CELL99
CELL100
CELL101
CELL102
CELL103
CELL104
SHOWERS SHOWERS
SHOWERSSHOWERS
OFFICE OFFICE
STORAGE STORAGE
VENDINGLAUNDRY OFFICE
COMMAND
CENTER
DAYROOM DAYROOM DAYROOM ELECTRICAL MECHANICAL
STAFF
STORAGE
CE
LL
CE
LL
CE
LL
IN
MAT
E
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
CE
LL
175 176
187 185 184 177 178
190 191 t r ix
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
N
OR
TH
RO
OK
S
R
OA
D
DC
DC DC
DC
DC
DC
DC
DMDM
LEGEND
DM
DC
DOOR WITH
STATUS
DOOR WITH
LOCK AND STATUS
NOTES
1. ALL INMATE CELLS HAVE SLIDING DOORS WHICH REQUIRE
AN OPEN AND CLOSE SIGNAL, HAVE A DOOR STATUS, HAVE AN
INMATE CALL BUTTON, AND HAVE A CONSTANT HOT
KEYSWITCH.
2. FIELD VERIFY ALL EXISTING CONTROLS AND WIRING
3. THERE IS ANOTHER CONTROLLED DOOR OPPOSITE OF THE
SEGREGRATION CONTROL DOOR THAT IS NOT SHOWN ON THIS
MAP.
4. THERE MAY BE ANOTHER CONTRL PANEL "C" LOCATED IN
THE MEDICAL AREA WHICH MAY MONITOR ANOTHER 8 DOORS
AND CONTROL ANOTHER 5 DOORS. THIS EXISTING PANEL MAY
NEED TO BE INCORPORATED INTO THE PLC, BUT NOT INTO THE
NEW HMI WITHIN SEGREGATION.
5. THERE MAY BE ANOTHER CONTROL PANEL "D" LOCATED IN
THE DINING ROOM WHICH MAY MONITOR ANOTHER 8 DOORS.
THIS EXISTING PANEL MAY NEED TO BE INCORPORATED INTO
THE PLC, BUT NOT INTO THE NEW HMI WITHIN SEGREGATION.
6. THERE ARE TWO DOORS AT THE ENTRANCE WHICH RECEIVE
POWER FROM THE HEADEND CABINET WHICH WILL STILL NEED
TO RECEIVE POWER.
P N
L A
P N
L B
TE1.3
BUILDING 200
BASE BID CONTROLS
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CE
LL
CE
LL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
CELL
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
M a t r ix
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
TE1.4
BUILDING 500, 1200
RISER DIAGRAMS
NEW
ETHERNET
SWITCH
CAT 6 CABLE
PNL A1
DOORS
PNL A2
DOORS
PNL B1
DOORS
PNL B2
DOORS
PNL C
DOORS
POWER
PANEL
CP A1 CP A2 CP C CP B1 CP B2
PLC
I/O
AENTR
I/O
REUSE EXISTING CABLING
8COND, 14AWG TYPICALLY FOR SLIDERS
4COND, 14AWG TYPICALLY FOR SWING
TERMINATE TO NEW I/O MODULES
500 & 1200
PLC/INPUT/OUTPUT
RELAY/MODULES
A2 PANEL
LOWER UPPER
CELL 92
CELL 93
CELL 94
CELL 95
CELL 96
CELL 97
CELL 98
CELL 99
CELL 100
CELL 101
CELL 102
CELL 103
CELL 104
CELL 12
CELL 13
CELL 14
CELL 15
CELL 16
CELL 17
CELL 18
CELL 19
CELL 20
CELL 21
CELL 22
CELL 23
CELL 24
B1 PANEL
LOWER UPPER
CELL 131
CELL 132
CELL 133
CELL 134
CELL 135
CELL 136
CELL 137
CELL 138
CELL 139
CELL 140
CELL 141
CELL 142
CELL 143
CELL 41
CELL 42
CELL 43
CELL 44
CELL 45
CELL 46
CELL 47
CELL 48
CELL 49
CELL 50
CELL 51
CELL 52
CELL 53
A1 PANEL
LOWER UPPER
CELL 81
CELL 82
CELL 83
CELL 84
CELL 85
CELL 86
CELL 87
CELL 88
CELL 89
CELL 90
CELL 91
CELL 1
CELL 2
CELL 3
CELL 4
CELL 5
CELL 6
CELL 7
CELL 8
CELL 9
CELL 10
CELL 11
B2 PANEL
LOWER UPPER
CELL 144
CELL 145
CELL 146
CELL 147
CELL 148
CELL 149
CELL 150
CELL 151
CELL 152
CELL 153
CELL 154
CELL 54
CELL 55
CELL 56
CELL 57
CELL 58
CELL 59
CELL 60
CELL 61
CELL 62
CELL 63
CELL 64
UPS
110VAC FROM
EMERGENCY PANEL
C PANEL
DM
DC
DC
DC
DC
DC
DC
DM
DM
DM
DM
DC
DC
DC
DC
DC
DC
DM
DM
DM
DM
175A
175B
176A
176B
178A
178B
177A
177B
182A
182B
DM170A
BUILDING 500 ONLY
9/2/2025 PHASE 500 - 90%
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
M a t r ix
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
TE1.5
BUILDING 200
RISER DIAGRAMS
NEW
ETHERNET
SWITCH
CAT 6 CABLE
PNL A
DOORS
PNL B
DOORS
PNL C
DOORS
PNL D
DOORS
CP A CP B CP C CP D
AENTR
I/O
PLC
I/O
REUSE EXISTING CABLING
8COND, 14AWG TYPICALLY FOR SLIDERS
4COND, 14AWG TYPICALLY FOR SWING
TERMINATE TO NEW I/O MODULES
PLC/INPUT/OUTPUT
RELAY/MODULES
C PANEL
B PANELA PANEL
CELL 42
CELL 43
CELL 44
CELL 45
CELL 46
CELL 47
CELL 48
CELL 49
CELL 50
CELL 51
D PANEL
UPS
110VAC FROM
EMERGENCY PANEL
9/2/2025 PHASE 500 - 90%
AENTR
I/O
CELL 57
CELL 58
CELL 59
CELL 60
CELL 61
CELL 62
CELL 63
CELL 64
CELL 65
CELL 66
CELL 67
CELL 68
DM
DM
DC
DC
DC
DC
DC
DC
DC
DC
DM
DM
DM
DC
DC
DC122
135A
135B
DM
DM
DM
DM
DC
DC
DC
DM
DM
DM
DM
DM
DM
DM
DM 12
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
PANEL KS | NTS
GANG
RELEASE
KS
PANEL
RESET
KS
TYPICAL FILLER PLATE FOR MOUNTING NEW HMI | NTS
PL
UR
IB
U
E S
U N U
M
C I
R C
U M
S P
I C
E
S I
Q U
E R
E I S
P E
N I
N S
U L
A M
A M
OE
N
A M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
P e t t i t t
M a n n
S t r a u b
S
LA
W
SO
N, C
M
IC
HI
GA
N
UI
TE
7-
F A
X
8-
8-
8-
8-
P
H O
N
EC
NO
RT
H
RO
OK
S
RO
AD
OFFICE
LIBRARY
ELECTRICAL
ROOM
MECHANICAL
ROOM
TELEVISION
ROOM
ACTIVE
RECREATION
PASSIVE
RECREATION
STORAGE
ROOM
SERVING
VENDING
LAUNDRY
HOUSE
STORE
INMATE
SHOWERS
OFFICE
VISITING
ROOM
DINING
ROOM
VESTIBULE
WOMEN'S
TOILET
MEN'S
TOILET
VESTIBULE
VESTIBULE
OFFICE
S
TOILET
JANITOR'S
CLOSET
INMATE
TOILET
CONTROL
LEVEL
STORM
ROOM
INMATE
INMATE
56UPPER
LO
W
ER
UP
PE
R
LO
WE
R LOWER
UPPER
HMI TYPICALS
NOTES:
1) MAIN SCREEN SHOWS OVERALL STATUS OF DOOR POSITION (RED), IF A CELL IS DESIGNATED FOR MEDICAL (BLUE), AND IF A CELL HAS BEEN TOPLOCKED (ORANGE).
2) NO DOOR CONTROL HAPPENS ON MAIN SCREEN
3) EACH WING SHALL HAVE A SCREEN SHOWING DOOR STATUS, INMATE CALL, AND HAVE CONTROL OPTIONS TO OPEN AND CLOSE.
4) GROUP OPEN/CLOSE SHALL ALLOW FOR MULTIPLE CELLS TO BE SELECTED AND OPENED OR CLOSED AT ONCE.
5) GANG RELEASE SHALL OPEN ALL DOORS. THIS MUST BE A MULTI STEP PROCESS, VIA A PASSCODE OR KEYSWITCH, SO AS TO NOT ALLOW ACCIDENTAL RELEASE. GANG RELEASE SHALL OVERRIDE TOPLOCK.
6) TOPLOCK SHALL RESTRICT THE CELL FROM BEING OPENED VIA THE OPEN BUTTON OR VIA GROUP RELEASE UNTIL TOPLOCK IS TURNED OFF.
7) MEDICAL SHALL INDICATE CELLS WHICH HOUSE INMATES THAT REQUIRE ADDITIONAL MEDICAL SUPPORT.
8) SCREENS SHALL BE CUSTOMIZED TO THE BUILDING AND AREA THEY ARE CONTROLLING TO GENERALLY REFLECT THE LAYOUT OF THE AREA.
9) ALL SCREENS SHOWN ARE EXAMPLES. FINAL DESIGN TO BE APPROVED BY FACILITY BEFORE DEPLOYMENT
10) ALL FUNCTIONS OF THE EXISTING POWER AND LIGHTING PANEL SHALL BE MOVED TO THE NEW HMI
11) KS PANEL SHALL REPLACE THE PREVIOUS POWER AND LIGHTING PANEL WITH TWO KEYSWITCHES. CORES TO BE PROVIDED BY FACILITY