N3319122R4010 Construct Fire and Rescue Station Attach 3 - Price Schedule.pdf
PDF 13 KB Posted
- Solicitation number
- ACQR5900578
About this file
This document contains a price schedule and related solicitation for a design-build construction project. The Naval Facilities Engineering Command is soliciting proposals to design and construct a new operational and certified Fire and Rescue Station located in Ocnita, Moldova.
The price schedule includes two contract line item numbers. CLIN 0001 is for the base requirement to design and construct a fire station with a minimum footprint of 620 square meters, including four truck bays and 600 square meters of heavy-duty pavement. CLIN 0002 is an optional line item to expand the project scope to include additional site development work such as a pad-mounted generator, more pavement, sidewalks, and a perimeter fence. Offerors are instructed to provide unit prices for each CLIN and a total proposed contract price in the table provided. Proposals must be submitted prior to an unspecified deadline.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 3
PRICE SCHEDULE
SOLICITATION N3319122R4010 D-B Construct Fire and Rescue Station, Ocnita, Moldova
INSTRUCTIONS:
In the table below provide the price for each CLIN and the total contract price.
Indicate name of the firm, sign and date the price schedule.
Submit this document with your price proposal.
CLIN Description
CLIN
Price
CLIN 0001 Base The contractor shall provide all labor, supervision, materials, equipment and applicable safety precautions necessary to design and construct a new operational and certified Fire and Rescue Station, connected with road infrastructure and provided with four (4) truck bays (one for cleaning) within a footprint of 620 m2.
The contractor shall provide a minimum of 600 m² of pavement, rated for heavy traffic in accordance with the Performance Technical Specifications
CLIN 0002 Option The contractor shall provide all labor, supervision, materials, equipment and applicable safety precautions necessary to design and construct the Fire and Rescue Station facility to include a Pad-mounted generator, additional 600 m² of heavy load pavement, new sidewalks along the roads adjacent to the plot of land (200 liner meters), perimeter fence (410 linear meters), and additional site development as necessary in accordance with the Performance Technical Specifications
TOTAL PRICE $
Firm: _______________________________________________
Name: _______________________________________________
Signature: _______________________________________________Date: _____________________