N32253-22-Q-0080
QUESTIONS AND ANSWERS
8/18/2022
QUESTION 1:
Could you please confirm if stainless steel will be acceptable.
ANSWER 1:
The manufacturer may provide a quotation for stainless steel vessels. Stainless steel vessels are not required to meet the internal epoxy-like lining of paragraph 5.1.8 of Attachment 1 and Attachment 2 Rev A. Stainless steel vessels shall still be free of grease, oil, flux and loose foreign material.
QUESTION 2:
We do not think that the outlet system will allow for adequate dewatering of the system. We would need more details from Navy on how you require this to be configured. This would need to be discussed more.
ANSWER 2:
Figure 1 in Attachment 1 and Attachment 2 Rev A are provided for guidance. The manufacturer can submit alternate outlet systems as long as the outlet system complies with Attachment 1 and Attachment 2 Rev A.
QUESTION 3:
Can you provide References 4 and 5?
ANSWER 3:
a. Reference 4 – see attachment
b. Reference 5 can be found on http://quicksearch.dla.mil/.
QUESTION 4:
How do you anticipate adding the filter media to the vessels?
ANSWER 4:
The filter media would be added through the vent pipe stubs. At this time, no removable port is required.