MZ-0079 Drawings.pdf
PDF 4 MB Posted
- Attached to
- Elephant Shade Canopies State and local contract opportunity
- Solicitation number
- MZ-0079
- Issued by
- Oklahoma County, Hobart City, Oklahoma
About this file
The document is a set of architectural and engineering drawings for the Elephant Shade Structures project at the Oklahoma City Zoo, with project number MZ-0079. The drawings detail the design for three shade sail structures (Sunshade A, B, and C) to be installed in the elephant paddock area, with specifications for commercial 95 shade fabric, steel pole foundations, and connection details. The project involves creating shade structures with specific dimensions, pole heights ranging from 22 to 28.5 feet, and requires the installation of feeder poles and sail fabric.
The drawings include comprehensive technical specifications for material selection, including primer and paint requirements for steel components (Macropoxy 646 Fast Cure Epoxy Primer and Hi-Solids Polyurethane Gloss by Sherwin Williams). Specific installation notes indicate that the fabric color will be selected by the owner from the manufacturer's standard color chart, and winches will be Dutton-Lainson Company B1500 Brake Winch models. The project appears to be part of the base bid and Alternate 1, with precise engineering details provided by Kirkpatrick Forest Curtis PC Structural Engineering, located in Oklahoma City.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| MZ-0079 Addendum 1.pdf | ||
| Anti Noncollusion Affidavit.pdf | ||
| Business Relationship Affidavit.pdf | ||
| MZ-0079 Project Manual.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
PROJECT No:
DRAWING No:
202410A DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
No DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
DECEMBER 2024
G1.0 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
DRAWING INDEX
G1.0 COVER
A0.1 SITE PLAN
A0.2 UTILITY PLAN
A1.1 PLAN VIEW
A2.1 ELEVATION
A3.1 DETAILS
STRUCTURAL
S1.0 GENERAL NOTES
S1.1 SPECIAL INSPECTION NOTES
S2.0 POLE LAYOUT
S6.0 SECTIONS Location Map1 SCALE: NOT TO SCALE
MEYERS PL
Oklahoma City Zoo
PROJECT
AREA
OKLAHOMA CITY ZOO
ELEPHANT SHADE STRUCTURES
12/20/2024 ISSUED FOR REVIEW
NOTES:
CLEAN AND PREP ALL STEEL PRIOR TO APPLICATION OF PRIMER.
PREP STEEL PER PRIMER MANUFACTURER'S INFORMATION.
APPLY ONE COAT OF MACROPOXY 646 FAST CURE EPOXY PRIMER,
#B58W00610 BY SHERWIN WILLIAMS, OR APPROVED EQUAL PRODUCT.
APPLY TO COATS HI-SOLIDS POLYURETHANE GLOSS #B65W00311 BY
SHERWIN WILLIAMS, OR APPROVED EQUAL PRODUCT. COLOR TO BE
SELECTED BY OWNER.
FABRIC SHALL BE COMMERCIAL 95 FABRIC. COLOR TO BE SELECTED
BY OWNER FROM MANUFACTURER'S STANDARD COLOR CHART.
WINCHES TO BE MODEL NUMBER B1500 BRAKE WINCH BY
DUTTON-LAINSON COMPANY.
ALL INFORMATION ON THIS SHEET APPLIES TO THE BASE BID AND
ALTERNATE 1.
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
Bid Items
AutoCAD SHX Text Cover Sheet
AutoCAD SHX Text 2000 Remington Place Elephant Shade Oklahoma City, Oklahoma 73111
CLOUDED
LEOPARD
1140.5
ELEPHANT
PADDOCK 2
2'
DUMP
& FILL
POND
HW HW
H W
HWHW
ELEPHANT
PADDOCK 2
2'
DUMP
& FILL
POND
HW HW
H W
HWHW
ELEPHANT
PADDOCK 2
2'
DUMP
& FILL
POND
HW HW
H W
HWHW
ELEPHANT
BARN
FFE 1122
EXISTING
HAY BARN
EXISTING
BLDG
EXISTING
BLDG
HW
HW
HW
HW
ELEPHANT
POOL
HW
HW
HW
HW
AZA
AZA
AZA
AZA
AZA
AZA
AZ
A
AZ
A
AZ
A
AZA
AZA
AZA
HW
HW
ELEPHANT
PADDOCK
HOLDING
BINS
HW
HW
HW
HW
H W
H W
H W
SERVICE
DRIVE
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
CLOUDED
LEOPARD
1140.5
ELEPHANT
PADDOCK 1
PROJECT No:
DRAWING No:
202410ANo DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
A0.1 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
Site Plan1 SCALE: 1" = 20'-0"
12/20/2024 ISSUED FOR REVIEW
DATE:
DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
DECEMBER 2024
PROPOSED ELEPHANT
SHADE BASE BID LOCATION
PROPOSED ELEPHANT
SHADE ALTERNATE #1
LOCATION
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text Site Plan
FD
FD
POOL
CLOUDED
LEOPARD
1140.5
RED
PANDA
ELEPHANT
PADDOCK 2
HW HW
H W
HWHW
C
LC
L
ELEPHANT
PADDOCK 2
HW HW
H W
HWHW
C
LC
L
ELEPHANT
PADDOCK 2
HW HW
H W
HWHW
C
LC
L
ELEPHANT
BARN
FFE 1122
EXISTING
HAY BARN
EXISTING
BLDG
EXISTING
BLDG
HW
HW
HW
ELEPHANT
POOL
HW
HW
HW
HW
AZA
AZA
AZA
AZ
A
AZ
A
AZ
A
AZA
AZA
AZA
HW
HW
HOLDING
BINS
HW
HW
H W
H W
H W
ELEPHANT
CALF
PADDOCK 1
SERVICE
DRIVE
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
E
BATHRO
O
M
E
LO
CKER RM
FD
FD
FD
FD
FD
FD
REF
FD
FD
FD
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
CLOUDED
LEOPARD
1140.5
RED
PANDA
HW
C L
+ 1135.24
2' DUMP &
FILL
POND
EXISTING
HAY BARN
EXISTING
BLDG
EX
MUSEUM
BLDG
CL
CL
CL
CL
CL
ELEPHANT
PADDOCK
8.3%
8.3%HW
HW
HW
H W
H W
H W
HW
HW
HW
HW
HW
HW
HW
HW
8' DUMP &
FILL
POND
SERVICE
DRIVE
HW HW
HW
HW
HW
+ 1137
+1125.08
HW
HW
HW
HW
HW
HW
CL CL CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
ELEPHANT
SIZE: ;11'X6'
ELEPHANT
SIZE: ;11'X6'
ELEPHANT
SIZE: ;11'X6'
1117.33
+ BELOW
(1115.58)
CL
CL
CL
CL
CL
CL
CL
CL
CL
C L
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL
CL CL CL CL CL
CL
CL
CL
CLCLCL
CL
CL
CL
CL
CL
1117.08 (DECK)
1115 (BELOW)
+ 1135.08 + 1134.50
CL
C L
C L
C L
CL
CL
CL
LP06
A
+1133.24 +1133.1
+1130.61 +1130.47
+1122.45 +1119.96
+1119.82
+1125.35
+1122.59
+1127.98 +1127.84
HW
HW
H W
ELEPHANT
BARN
FFE 1122
HB
HB
W
W W
W
HW
HW
HW
HW
HW
HW
CL
CL
PROJECT No:
DRAWING No:
202410ANo DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
A0.2 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
Utility Plan1 SCALE: 1" = 20'-0"
12/20/2024 ISSUED FOR REVIEW
DATE:
DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
DECEMBER 2024
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
PROPOSED ELEPHANT
SHADE BASE BID LOCATION
PROPOSED ELEPHANT
SHADE ALTERNATE #1
LOCATION
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E3
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E21
AutoCAD SHX Text
PUMP
AutoCAD SHX Text E11
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E14
AutoCAD SHX Text
STALL 2
AutoCAD SHX Text E13
AutoCAD SHX Text
STALL 1
AutoCAD SHX Text E17
AutoCAD SHX Text
BULL STALL 1
AutoCAD SHX Text E20
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E1
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E8
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E9
AutoCAD SHX Text
KEEPER CORRIDOR
AutoCAD SHX Text E12
AutoCAD SHX Text
COMMUNITY STALL
AutoCAD SHX Text E16
AutoCAD SHX Text
MATERNITY
AutoCAD SHX Text E15
AutoCAD SHX Text
STALL 3
AutoCAD SHX Text E18
AutoCAD SHX Text
BULL STALL 2
AutoCAD SHX Text E10
AutoCAD SHX Text
SHIFT
AutoCAD SHX Text E19
AutoCAD SHX Text
BULL STALL 3
AutoCAD SHX Text E2
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text E6
AutoCAD SHX Text
KEEPER ACCESS
AutoCAD SHX Text E7
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
TC
AutoCAD SHX Text
AC
AutoCAD SHX Text
AC
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
ASPHALT
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text ss
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
BENCHMARK: #37 CUT X ELEVATION=1139.61
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
U/G GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text
GAS
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text Utility Plan
1 2
1 2
PROJECT No:
DRAWING No:
202410ANo DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
A1.1 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
Sail Plan1 SCALE: 1/8" = 1'-0"
12/20/2024 ISSUED FOR REVIEW
DATE:
DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
DECEMBER 2024
Pole Plan2 SCALE: 1/8" = 1'-0"
SUNSHADE A
SUNSHADE B
SUNSHADE C
SHADE SAIL CONNECTION
POLE INFORMATION
A B C
1 22.0 28.5 27.0
2 28.5
3 28.5 22.0
4 28.5 22.0
5 22.0
6 28.5
7 27.0
8 22.0
NOTES:
COMMERCIAL 95 SHADE FABRIC.
COLOR TO BE SELECTED BY OWNER
PROVIDE STANDARD SAMPLES FOR
SELECTION.
ALL INFORMATION ON THIS SHEET
APPLIES TO THE BASE BID AND
ALTERNATE 1.Distance in feet from ground level to attachment point of sail.
Feeder Pole Location
Feeder Pole Location
Feeder Pole Location
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 12'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 88'-0"
AutoCAD SHX Text 70'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 12'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 30'-0"
AutoCAD SHX Text 88'-0"
AutoCAD SHX Text 70'-0"
AutoCAD SHX Text Plan Views
DRAWING No:
202410ANo DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
A2.1 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
Elevation View1 SCALE: 1/4" = 1'-0"
12/20/2024 ISSUED FOR REVIEW
DATE:
DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
DECEMBER 2024
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
NOTES:
COMMERCIAL 95 SHADE FABRIC.
COLOR TO BE SELECTED BY OWNER
PROVIDE STANDARD SAMPLES FOR
SELECTION.
ALL INFORMATION ON THIS SHEET
APPLIES TO THE BASE BID AND
ALTERNATE 1.
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 22'-0"
AutoCAD SHX Text 6'-6"
AutoCAD SHX Text 22'-0"
AutoCAD SHX Text 27'-0"
AutoCAD SHX Text Elevation
DRAWING No:
202410ANo DATE DESCRIPTION APP
REVISIONS
SCALE BAR IS ONE INCH
ON ORIGINAL DRAWINGS
0 1"
A3.1 12/20/24
SMCGARRAUGH@OKCZOO.ORG w(405)425-0680 m(214)883-7712 OKLAHOMA LICENSED ARCHITECT NO. a4440
Steven L McGarraugh, AIA
Feeder Pole Details1 SCALE: 1/4" = 1'-0"
12/20/2024 ISSUED FOR REVIEW
DATE:
DESIGNED BY: SLMc
DRAWN BY: SLMc
CHECKED BY: JD/TL/RM
APPROVED BY: TL
DECEMBER 2024
REMOVABLE
COVER
5' CABLE SHIELDS
(SEE STRUCTURAL
FOR DETAILS)
1 02/07/2025 ISSUED FOR PERMIT AND CONSTRUCTION
City of Oklahoma City Project Number MZ-0079
NOTES:
COMMERCIAL 95 SHADE FABRIC.
COLOR TO BE SELECTED BY OWNER
PROVIDE STANDARD SAMPLES FOR
SELECTION.
ALL INFORMATION ON THIS SHEET
APPLIES TO THE BASE BID AND
ALTERNATE 1.
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 15'-0"
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 22'-0"
AutoCAD SHX Text 4'-3"
AutoCAD SHX Text Plans, Elevations, and Details
1) GENERAL INFORMATION
A. GOVERNING BUILDING CODE: IBC-2018 "INTERNATIONAL BUILDING CODE" WITH CITY OF
OKLAHOMA CITY AMENDMENTS.
B. BUILDING RISK CATEGORY: THE BUILDING RISK CATEGORY ACCORDING TO IBC-2018
TABLE 1604.5 AND ASCE 7-16 TABLE 1.5-1 IS CATEGORY II.
C. ELEVATIONS: REFERENCE FINISHED FLOOR ELEVATIONS OF 100'-0" EQUALS ACTUAL
EXISTING FINISH GRADE.
D. CONTRACT DOCUMENTS:
1) THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT BETWEEN THE OWNER AND
CONTRACTOR, CONDITIONS OF THE CONTRACT, DRAWINGS, SPECIFICATIONS, ADDENDA
ISSUED PRIOR TO EXECUTION OF THE CONTRACT, OTHER DOCUMENTS LISTED IN THE
AGREEMENT AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT.
2) THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND DISSEMINATING ALL
CONTRACT DOCUMENTS AND LATEST ADDENDA TO ALL SUB-CONTRACTORS PRIOR TO
DETAILING, FABRICATION, OR INSTALLATION OF WORK.
3) CORRELATION OF THE CONTRACT DOCUMENTS: THE CONTRACT DOCUMENTS ARE
COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF
REQUIRED BY ALL. IF CONFLICTING REQUIREMENTS ARE FOUND BETWEEN THE
DRAWINGS, SPECIFICATIONS AND/OR THESE GENERAL NOTES, THE MORE STRINGENT
AND HIGHEST COST REQUIREMENT SHALL CONTROL UNLESS DIRECTED OTHERWISE IN
WRITING BY THE OWNER'S REPRESENTATIVE.
4) THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL AND STRUCTURAL
DRAWINGS FOR DISCREPANCIES BETWEEN EACH SET, AND WITHIN EACH SET OF
DRAWINGS, AND REPORT DISCREPANCIES, IF ANY, TO THE OWNER'S REPRESENTATIVE
PRIOR TO THE DETAILING, FABRICATION, AND INSTALLATION OF AFFECTED WORK.
5) GENERAL CONTRACTOR SHALL COORDINATE SIZES AND LOCATIONS OF OPENINGS
THROUGH FLOORS, ROOF, AND WALLS SHOWN ON ELECTRICAL, PLUMBING, AND FIRE
SUPPRESSION SYSTEM DESIGN DOCUMENTS WITH ASSOCIATED SUBCONTRACTORS.
6) ALTHOUGH NOT NECESSARILY SPECIFICALLY REFERENCED IN THE CONTRACT
DOCUMENTS, TYPICAL DETAILS AND GENERAL NOTES APPLY TO THE ENTIRE PROJECT
WHEREVER CONDITIONS SIMILAR TO THOSE DETAILED OR NOTED EXIST.
7) THE USE OF ELECTRONIC FILES OR REPRODUCTION OF CONTRACT DOCUMENTS BY ANY
TRADE OR MATERIAL SUPPLIER IN LIEU OF COMPLETELY INDEPENDENT PREPARATION
OF SHOP DRAWINGS SIGNIFIES THE SUPPLIER'S CERTIFICATION THAT ALL
INFORMATION SHOWN IN THE SHOP DRAWINGS IS CORRECT, AND ASSIGNS THEMSELVES
TO RESPONSIBILITY FOR ANY JOB EXPENSE ARISING DUE TO ANY ERRORS OCCURRING
THEREIN.
E. FIELD MODIFICATIONS: CONTRACTOR OR SUBCONTRACTOR FIELD MODIFICATIONS TO THE
STRUCTURE WITHOUT THE PRIOR WRITTEN CONSENT OF THE STRUCTURAL ENGINEER ARE
EXPRESSLY PROHIBITED AND MAY REQUIRE SUBSEQUENT REMEDIATION DIRECTED BY THE
STRUCTURAL ENGINEER AT CONTRACTOR'S EXPENSE.
2) DESIGN LOADS
A. GOVERNING STANDARD FOR DESIGN LOADS: ASCE 7-16 "MINIMUM DESIGN LOADS FOR
BUILDINGS AND OTHER STRUCTURES"
B. DEAD LOAD: SELF WEIGHT OF MATERIALS, UNLESS NOTED OTHERWISE
C. LIVE LOADS:
1) FABRIC ROOF:.................................................5 PSF
2) ELEPHANT:......................10 KIPS AT 7'-0" ABOVE FINISH GRADE
D. WIND LOADS:
1) RISK CATEGORY: .................................................II
2) EXPOSURE CATEGORY:...............................................C
3) ENCLOSURE CLASSIFICATION..................................ENCLOSED
4) INTERNAL PRESSURE COEFFICIENT, GCPI:....... ..............+/- 0.18
5) TOPOGRAPHIC FACTOR, KZT:.......................................1.0
6) DIRECTIONALITY FACTOR, KD:....................................0.85
7) ULTIMATE DESIGN WIND SPEED, Vult:..........................109 MPH
8) NOMINAL DESIGN WIND SPEED, Vasd:............................90 MPH
9) FABRIC DESIGN WIND PRESSURE:..............................30.0 PSF
E. SNOW LOADS:
1) SNOW IMPORTANCE FACTOR, Is:....................................1.0
2) GROUND SNOW LOAD, Pg:.......................................10 PSF
3) EXPOSURE OF ROOF: ...............................PARTIALLY EXPOSED
4) SURFACE ROUGHNESS CATEGORY:......................................C
5) EXPOSURE FACTOR, Ce:...........................................1.0
6) THERMAL FACTOR, Ct:............................................1.2
7) ROOF SLOPE FACTOR, Cs:.........................................1.0
8) CALCULATED FLAT ROOF SNOW LOAD, Pf:........................8.4 PSF
9) MINIMUM FLAT ROOF SNOW LOAD, I*Pg:........................13.4 PSF
F. ICE LOADS:
1) ICE IMPORTANCE FACTOR, Ii:.....................................1.0
2) NOMINAL ICE THICKNESS, t:..................................1.50 IN
3) DESIGN ICE THICKNESS, td:..................................1.48 IN
4) UNIFORM ICE LOAD:.........................................13.0 PSF
5) ULTIMATE DESIGN WIND ON ICE SPEED, Vult:....................40 MPH
G. RAIN LOADS:
1) 15-MINUTE RAIN INTENSITY..........................7.81 INCHES/HOUR
2) 60-MINUTE RAIN INTENSITY..........................3.94 INCHES/HOUR
H. SEISMIC DESIGN CRITERIA:
1) RISK CATEGORY: .................................................II
2) SEISMIC IMPORTANCE FACTOR, Ie:................................1.00
3) SOIL SITE CLASSIFICATION (ASSUMED):..............................D
4) 0.2 SEC. MAPPED SPECTRAL ACCELERATION, Ss:...................0.298
5) 1.0 SEC. MAPPED SPECTRAL ACCELERATION, S1:...................0.080
6) SITE COEFFICIENT, 0.2 SEC. PERIOD, Fa:.......................1.562
7) SITE COEFFICIENT, 1.0 SEC. PERIOD, Fv:.......................2.400
8) 0.2 SEC. DESIGN SPECTRAL ACCELERATION, Sds:..................0.310
9) 1.0 SEC. DESIGN SPECTRAL ACCELERATION, Sd1:..................0.128
10)SEISMIC DESIGN CATEGORY:.........................................B
11)SEISMIC PARAMETERS FOR BUILDING:
A) SEISMIC FORCE RESISTING SYSTEM: STEEL ORDINARY CANTILEVER COLUMN
SYSTEMS
B) RESPONSE MODIFICATION COEFFICIENT, R:.....................1.25
C) SYSTEM OVERSTRENGTH FACTOR, O:............................1.25
D) DEFLECTION AMPLIFICATION FACTOR, Cd:......................1.25
E) ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE METHOD.
F) SEISMIC RESPONSE COEFFICIENT, Cs:........................0.248
G) TOTAL LATERAL BASE SHEAR, V:..........................3.0 KIPS
3) MATERIAL DESIGN VALUES
A. CONCRETE (MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS, NORMAL WEIGHT
U.N.O.)
1) DRILLED PIERS AND SHAFTS.................................4,O00 PSI
2) ALL OTHER STRUCTURAL CONCRETE, U.N.O:....................4,000 PSI
B. CONCRETE REINFORCEMENT (MINIMUM YIELD STRENGTH)
1) ALL PLAIN AND DEFORMED BARS (ASTM A615, GRADE 60)......FY = 60 KSI
2) WELDED PLAIN WIRE REINFORCEMENT (ASTM A1064)...........FY = 65 KSI
3) WELDED DEFORMED WIRE REINFORCEMENT (ASTM A1064)........FY = 70 KSI
4) WELDABLE REINFORCING BARS (ASTM A706) .................FY = 60 KSI
C. STRUCTURAL STEEL (MINIMUM YIELD STRENGTH)
1) ALL WIDE FLANGE SHAPES (ASTM A992)....................FY = 50 KSI
2) SQUARE AND RECTANGULAR HSS (ASTM A500, GRADE C)........FY = 50 KSI
3) ROUND HSS (ASTM A500, GRADE C).........................FY = 46 KSI
4) PIPES (ASTM A53, GRADE B)..............................FY = 35 KSI
5) ALL OTHER SHAPES AND PLATES UNLESS NOTED (ASTM A36)....FY = 36 KSI
(FABRICATOR MAY OPTIONALLY USE ASTM A572-50 PLATE MATERIAL)
4) CONSTRUCTION LOADS AND STABILITY
A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL TEMPORARY CONSTRUCTION
LOADS CAN BE SAFELY SUPPORTED BY THE STRUCTURE DURING CONSTRUCTION.
B. THE STRUCTURAL FRAMING SYSTEM AND FOUNDATIONS HAVE BEEN DESIGNED AS A
COMPLETE STRUCTURAL SYSTEM FOR SUPPORT OF THE LOADS INDICATED IN THE
CONSTRUCTION DOCUMENTS. THE STRUCTURE HAS NOT BEEN DESIGNED OR CHECKED FOR
TEMPORARY CONSTRUCTION LOADS NOR HAS IT BEEN DESIGNED OR CHECKED FOR
ADEQUACY OR STABILITY AS A PARTIALLY ERECTED STRUCTURE.
C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING THE ABILITY OF THE
PARTIALLY COMPLETED OR FULLY COMPLETED STRUCTURE TO RESIST ALL CONSTRUCTION
LOADS INCLUDING BUT ARE NOT NECESSARILY LIMITED TO MATERIAL STAGING,
PERSONNEL, AND EQUIPMENT.
D. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORES, GUYS, BRACES, AND OTHER
SUPPORTS DURING CONSTRUCTION TO KEEP STRUCTURAL FRAMING COMPONENTS SECURE,
PLUMB, AND IN ALIGNMENT AGAINST TEMPORARY CONSTRUCTION LOADS AND LOADS EQUAL
IN INTENSITY TO DESIGN LOADS. THE TEMPORARY SUPPORTS SHALL BE SUFFICIENT TO
SECURE THE PARTIALLY ERECTED STRUCTURE OR ANY PORTION THEREOF AGAINST LOADS
THAT ARE LIKELY TO BE ENCOUNTERED DURING CONSTRUCTION, INCLUDING THOSE DUE
TO WIND AND THOSE THAT RESULT FROM CONSTRUCTION OPERATIONS.
E. THE CONTRACTOR SHALL NOT REMOVE TEMPORARY SUPPORTS UNTIL THE INSTALLATION OF
ALL STRUCTURAL ELEMENTS IS COMPLETE AND HAS BEEN ACCEPTED AS COMPLETE BY THE
ENGINEER. FOR THE PURPOSES OF THIS PARAGRAPH, "ALL STRUCTURAL ELEMENTS"
INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING STRUCTURAL
ELEMENTS:
1) FOUNDATIONS
2) STRUCTURAL STEEL POSTS.
5) DEFERRED SUBMITTALS
A. SOME STRUCTURAL AND/OR OTHER BUILDING ELEMENTS ARE DESIGNATED AS
VENDOR-DESIGNED IN THE CONSTRUCTION DOCUMENTS. THESE ELEMENTS HAVE NOT BEEN
INCLUDED IN THE BUILDING PERMIT ISSUED BY THE BUILDING OFFICIAL AND REQUIRE
THEIR DESIGN BE SUBSTANTIATED BY DEFERRED SUBMITTALS.
B. DEFERRED DESIGN SUBMITTALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE
AND SHALL INCLUDE BOTH SHOP DRAWINGS AND SIGNED AND SEALED CALCULATIONS
PERFORMED BY AN ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED
AND EXPERIENCED IN THE DESIGN OF THE SPECIFIC BUILDING ELEMENT BEING
SUBMITTED. THE FOLLOWING ITEMS ARE CONSIDERED DEFERRED SUBMITTALS::
1) SUNSHADE FABRIC DESIGN AND ASSOCIATED CONNECTIONS
C. DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE OWNER'S
REPRESENTATIVE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING
OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS
HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF
THE BUILDING.
D. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY BOTH THE OWNER'S REPRESENTATIVE
AND THE BUILDING OFFICIAL.
E. ADDITIONAL ITEMS IMPACTING STRUCTURAL DESIGN, INCLUDING BUT NOT LIMITED TO,
ELEVATORS AND MECHANICAL EQUIPMENT WEIGHTS, SHALL BE SUBMITTED TO OWNER'S
REPRESENTATIVE FOR EVALUATION
6) FOUNDATION NOTES:
A. EMBED POLE PIER FOUNDATIONS:
1) GOVERNING CODES AND STANDARDS: IN ADDITION TO THE REQUIREMENTS OF THE
GOVERNING INTERNATIONAL BUILDING CODE, ALL DRILLED PIERS SHALL BE
DETAILED AND INSTALLED IN ACCORDANCE WITH THE FOLLOWING CODES AND
STANDARDS AND AS SUPPLEMENTED BY THESE GENERAL NOTES AND THE PROJECT
DRAWINGS AND SPECIFICATIONS.
A) ACI 336.1-01 "SPECIFICATION FOR THE CONSTRUCTION OF DRILLED PIERS"
2) EMBED POLE PIER FOUNDATION DESIGN PARAMETERS: THE PROPOSED STRUCTURE
SHALL BE SUPPORTED ON EMBED POLE FOUNDATIONS BASED ON THE FOLLOWING IBC
PRESUMPTIVE DESIGN PARAMETERS:
A) SOIL TYPE: SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY
GRAVEL
B) ALLOWABLE END BEARING PRESSURE: 1500 PSF
C) ALLOWABLE LATERAL BEARING PRESSURE: 150 PSF
3) CASING REQUIREMENTS: TEMPORARY CASING MAY BE REQUIRED IN ORDER TO SEAL
OUT GROUNDWATER OR SLOUGHING SOILS, HOWEVER THE FINAL DETERMINATION SHALL
BE MADE AT THE TIME OF CONSTRUCTION.
A) THE CONTRACTOR SHALL PROVIDE UNIT PRICING TO ADD THE COST OF EACH
LINEAL FOOT OF CASING FOR EACH PIER DIAMETER IN THE EVENT CASINGS ARE
REQUIRED. UNIT LENGTHS OF CASING SHALL BE FROM DETAILED TOP OF PIER
ELEVATION TO TOP OF BEARING STRATUM ELEVATION.
B) THE CONTRACTOR SHALL PROVIDE UNIT PRICING FOR THE COST OF ABANDONED
CASINGS THAT CANNOT BE REMOVED FOR REASONS BEYOND THE CONTROL OF THE
CONTRACTOR.
4) PIER CONSTRUCTION:
A) THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING
UTILITIES, BOTH CHARTED AND UNCHARTED, PRIOR TO COMMENCING WITH
EXCAVATION OR PIER DRILLING OPERATIONS AND SHALL IMMEDIATELY NOTIFY
THE OWNER'S REPRESENTATIVE OF ANY POTENTIAL CONFLICTS BETWEEN EXISTING
CONDITIONS AND PLANNED CONSTRUCTION.
B) SOFT OR LOOSE SOIL ZONES ENCOUNTERED AT THE BEARING LEVEL SHALL BE
REMOVED FROM THE DRILLED SHAFTS. IF THE EXPOSED BEARING MATERIALS
BECOME SIGNIFICANTLY WET OR DRY, THEY SHALL BE DEEPENED UNTIL MORE
UNIFORM MOISTURE CONDITIONS ARE ACHIEVED AS DIRECTED BY THE
GEOTECHNICAL ENGINEER.
C) CONCRETE FOR PIERS SHALL BE CAST AS SOON AS PRACTICAL AFTER DRILLING.
IN GENERAL, NO PIER HOLE SHALL BE LEFT OPEN OVERNIGHT. IF THE PIERS
ARE LEFT OPEN OVERNIGHT OR LONGER, THE PIER DRILLING CONTRACTOR SHALL
DEEPEN PIERS A MINIMUM OF ONE PIER DIAMETER AT THE CONTRACTOR'S
EXPENSE.
D) THE TOP FIVE FEET OF ALL PIERS SHALL BE VIBRATED AFTER TEMPORARY
CASING HAS BEEN WITHDRAWN OR WHEN CASING IS PERMANENT AND CONCRETE
SLUMP IS LESS THAN 6 INCHES.
E) ANY CONCRETE OVERPOUR AT TOP OF PIERS (MUSHROOMS) SHALL BE REMOVED TO
PRODUCE THE SPECIFIED PIER DIAMETER.
B. FOUNDATION MISCELLANEOUS
1) GROUNDWATER CONDITIONS: IT IS POSSIBLE THAT TRANSIENT OVER-SATURATED
GROUND CONDITIONS COULD DEVELOP AT SHALLOW DEPTHS DUE TO PERIODS OF
HEAVY PRECIPITATION, LANDSCAPE WATERING, LEAKING WATER LINES, OR OTHER
UNFORESEEN CAUSES. THE CONTRACTOR SHALL DETERMINE THE ACTUAL
GROUNDWATER LEVELS AT TIME OF CONSTRUCTION. IF GROUNDWATER ISSUES ARE
ENCOUNTERED DURING CONSTRUCTION, A GEOTECHNICAL ENGINEER SHALL BE
CONTACTED AND REQUESTED TO ASSESS THE POSSIBLE NEED FOR REMEDIAL
MEASURES.
2) CONSTRUCTION MONITORING: A GEOTECHNICAL ENGINEER SHALL BE RETAINED TO
PROVIDE OBSERVATIONS AND TESTING OF SOILS EXPOSED DURING PROJECT
CONSTRUCTION IN ORDER TO VERIFY THAT SOIL CONDITIONS ARE AS ANTICIPATED.
CONSTRUCTION ACTIVITIES PERTAINING TO EARTHWORK AND OTHER RELATED
ACTIVITIES SHALL ALSO BE OBSERVED BY THE GEOTECHNICAL ENGINEER.
7) CONCRETE CONSTRUCTION NOTES
A. GOVERNING CODES AND STANDARDS: IN ADDITION TO THE REQUIREMENTS OF THE
GOVERNING INTERNATIONAL BUILDING CODE, ALL CONCRETE SHALL BE DETAILED,
FABRICATED, AND ERECTED IN ACCORDANCE WITH THE FOLLOWING CODES AND STANDARDS
AND AS SUPPLEMENTED BY THESE GENERAL NOTES AND THE PROJECT DRAWINGS AND
SPECIFICATIONS.
1) ACI 117-10 "SPECIFICATION FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND
MATERIALS"
2) ACI 301-10 "SPECIFICATIONS FOR STRUCTURAL CONCRETE"
3) ACI 318-14 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
4) ACI 347-04 "GUIDE TO FORMWORK FOR CONCRETE"
5) ACI SP-66(04) "ACI DETAILING MANUAL"
6) AWS D1.4-2011 "STRUCTURAL WELDING CODE - REINFORCING STEEL".
7) CRSI MSP-2018 "CRSI MANUAL OF STANDARD PRACTICE"
B. CONCRETE MIXTURES:
1) CEMENTITIOUS MATERIALS
A)OPTION 1 - ORDINARY PORTLAND CEMENT (OPC): ASTM C150 TYPE I OR II
UNLESS SPECIFICALLY NOTED OTHERWISE.
B) OPTION 2 - PORTLAND LIMESTONE CEMENT (PLC): ASTM C595 TYPE IL UNLESS
SPECIFICALLY NOTED OTHERWISE.
C) FLY ASH: ASTM C618 CLASS C OR F. THE MAXIMUM PERCENTAGE OF FLY ASH
SHALL NOT EXCEED 25 PERCENT OF THE TOTAL CEMENTITIOUS MATERIAL.
2)ALL CONCRETE MIXES SHALL BE COMPRISED OF NORMAL WEIGHT AGGREGATES
CONFORMING TO ASTM C33, EXCEPT WHERE SPECIFICALLY INDICATED AS
LIGHTWEIGHT, IN WHICH CASE AGGREGATES SHALL CONFORM TO ASTM C330.
3)MIXING WATER SHALL CONFORM TO ASTM C1062. MIXING WATER, INCLUDING THAT
PORTION OF MIXING WATER CONTRIBUTED IN THE FORM OF FREE MOISTURE ON
AGGREGATES, SHALL NOT CONTAIN DELETERIOUS AMOUNTS OF CHLORIDE IONS.
4)ADMIXTURES, IF USED, SHALL CONFORM TO THE FOLLOWING:
A) WATER REDUCTION AND SETTING TIME MODIFICATION: ASTM C494.
B) PRODUCING FLOWING CONCRETE: ASTM C1017.
C) AIR ENTRAINMENT: ASTM C260.
D) INHIBITING CHLORIDE INDUCED CORROSION: ASTM C1582.
5)MIX DESIGNS SHALL BE PROPORTIONED BASED ON THE FOLLOWING MIX
CHARACTERISTICS;
A) EMBED POLE FOUNDATIONS
1) FREEZING AND THAWING EXPOSURE CATEGORY (F): CLASS F0
2) SULFATE EXPOSURE CATEGORY (S): CLASS S0
3) WATER EXPOSURE CATEGORY (W): CLASS W1
4) CORROSION PROTECTION CATEGORY (C): CLASS C0
5) 28-DAY COMPRESSIVE STRENGTH: 4,000 PSI
6) MAXIMUM WATER/CEMENT RATIO: 0.50
7) MAXIMUM AGGREGATE SIZE: 1 1/2 INCHES
8) TARGET AIR CONTENT: NO AIR ENTRAINMENT REQUIRED.
9) SLUMP RANGE:
(i) DRY, UNCASED OR PERMANENT CASING: 4 TO 6 INCHES
(ii) TEMPORARY CASING: 6 TO 8 INCHES (iii)SLURRY DISPLACEMENT: 7 TO 9 INCHES
10)MAXIMUM WATER-SOLUBLE CHLORIDE ION CONTENT IN CONCRETE, PERCENT BY
WEIGHT OF CEMENTITIOUS MATERIALS: 0.30
11)WATER REDUCING AND RETARDING ADMIXTURE: AS REQUIRED TO ENSURE
MINIMUM SLUMP REQUIREMENT IS MAINTAINED DURING REMOVAL OF
TEMPORARY CASINGS.
6)CONCRETE MIX PROPORTIONS SHALL BE ESTABLISHED IN ACCORDANCE WITH ARTICLE
4.2.3 OF ACI 301 SO THAT THE CONCRETE SATISFIES THE FOLLOWING THREE
REQUIREMENTS:
A) THE CONCRETE CAN BE PLACED READILY WITHOUT SEGREGATION INTO FORMS AND
AROUND REINFORCEMENT UNDER ANTICIPATED PLACEMENT CONDITIONS. THE
CONCRETE PRODUCER SHALL DETERMINE WHETHER ADMIXTURES ARE NECESSARY
FOR WATER REDUCTION, SET TIME, OR SLUMP REQUIREMENTS.
B) THE CONCRETE SHALL MEET REQUIREMENTS FOR THE ASSIGNED EXPOSURE CLASSES
OUTLINED HEREIN.
C) THE CONCRETE SHALL CONFORM TO STRENGTH TEST REQUIREMENTS FOR
STANDARD-CURED SPECIMENS.
7) DOCUMENTATION OF CONCRETE MIXTURE CHARACTERISTICS, CURRENT WITHIN THE
PAST 24 MONTHS, SHALL BE SUBMITTED FOR REVIEW BEFORE THE MIXTURE IS USED.
EVIDENCE OF THE ABILITY OF THE PROPOSED MIXTURE TO COMPLY WITH THE
CONCRETE MIXTURE REQUIREMENTS IN THE CONSTRUCTION DOCUMENTS SHALL BE
INCLUDED IN THE SUBMITTAL. THE EVIDENCE SHALL BE BASED ON FIELD TEST
RECORDS OR LABORATORY TRIAL BATCHES.
8) STEEL CONSTRUCTION NOTES
A. GOVERNING CODES AND STANDARDS: IN ADDITION TO THE REQUIREMENTS OF THE
GOVERNING INTERNATIONAL BUILDING CODE, ALL STRUCTURAL STEEL SHALL BE
DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE FOLLOWING STANDARDS
AND AS SUPPLEMENTED BY THESE GENERAL NOTES AND THE PROJECT DRAWINGS AND
SPECIFICATIONS.
1) AISC 303-16 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES"
2) AISC 341-16 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS"
3) AISC 360-16 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
4) AWS D1.1-2015 "STRUCTURAL WELDING CODE - STEEL"
5) RCSC-2014 "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS"
B. STEEL FABRICATION & FINISH:
1) SHOP DRAWINGS SHALL BE SUBMITTED TO AND REVIEWED BY THE OWNER'S
REPRESENTATIVE PRIOR TO COMMENCING FABRICATION. ANY FABRICATION INITIATED
PRIOR TO APPROVAL OF SHOP DRAWINGS WILL BE AT THE SOLE RISK OF THE
FABRICATOR.
2) ALL SHOP AND FIELD WELDS SHALL BE MADE IN ACCORDANCE WITH AWS D1.1. ALL
WELDING SHALL USE LOW HYDROGEN PROCESSES.
3) CUTS, HOLES, COPING, ETC. REQUIRED FOR WORK OF OTHER TRADES SHALL BE
SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING OF
HOLES IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.
4) SHOP PRIMER
A) ALL STEEL EXPOSED TO EXTERIOR WEATHER OR AN UNCONTROLLED ENVIRONMENT
SHALL BE BLAST CLEANED AND PRIMED WITH A SUBMITTED AND APPROVED
ZINC-RICH PRIMER.
B) SHOP PRIMER SHALL NOT BE APPLIED TO THE FOLLOWING AREAS:
i) SURFACES EMBEDDED IN CONCRETE OR MORTAR. EXTEND PRIMING OF
PARTIALLY EMBEDDED MEMBERS TO A DEPTH OF 2 INCHES.
ii) SURFACES TO BE FIELD WELDED.
iii) SURFACES TO BE HIGH-STRENGTH BOLTED WITH SLIP-CRITICAL
CONNECTIONS.
iv) SURFACES TO RECEIVE SPRAYED FIRE-RESISTIVE MATERIALS.
v) GALVANIZED SURFACES.
9) SUNSHADE NOTES
A. BASIS OF DESIGN SUNSHADE SHALL BE COMMERCIAL NINETY FIVE 340 HDPE FABRIC.
COLOR SHALL BE BY OWNER.
B. ALL SUNSHADE SUPPORT CABLES SHALL BE 5/16" 1X7 EHS GALVANIZED STEEL STRAND
WITH A MINIMUM BREAKING STRENGTH OF 11.2 KIPS.
C. SUBMIT SIGNED AND SEALED DESIGN ANALYSIS INDICATING POLE REACTIONS FOR
VERIFICATION OF POLE AND FOUNDATION DESIGN.
1. STATEMENT OF SPECIAL INSPECTIONS NOTES:
A. THIS STATEMENT OF SPECIAL INSPECTIONS IS INCLUDED AS REQUIRED BY SECTION
1704.3 OF CHAPTER 17 OF 2018 INTERNATIONAL BUILDING CODE.
B. SPECIAL INSPECTIONS SHALL CONFORM TO CHAPTER 17 OF THE 2018 INTERNATIONAL
BUILDING CODE, AISC 360, AND ACI 530 AS SUMMARIZED HEREIN. GENERAL
REQUIREMENTS ARE LISTED BELOW AND IN THE ATTACHED INSPECTION TABLES.
C. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL SPECIAL INSPECTION
REQUIREMENTS. IF CONFLICTING REQUIREMENTS ARE FOUND BETWEEN STATEMENTS OF
SPECIAL INSPECTIONS AND THE PROJECT SPECIFICATIONS, THE MORE STRINGENT
PROVISION SHALL CONTROL UNLESS DIRECTED OTHERWISE IN WRITING BY THE
STRUCTURAL ENGINEER OF RECORD.
D. THE OWNER SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS FOR THIS PROJECT. THE
SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE
COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR THE INSPECTION
OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL
INSPECTION.
E. PRIOR TO THE START OF CONSTRUCTION, EACH SPECIAL INSPECTOR SHALL PROVIDE
WRITTEN DOCUMENTATION TO THE BUILDING OFFICIAL DEMONSTRATING HIS OR HER
COMPETENCE AND RELEVANT EXPERIENCE OR TRAINING. EXPERIENCE OR TRAINING SHALL
BE CONSIDERED RELEVANT WHEN THE DOCUMENTED EXPERIENCE OR TRAINING IS RELATED
IN COMPLEXITY TO THE SAME TYPE OF SPECIAL INSPECTION ACTIVITIES FOR PROJECTS
OF SIMILAR COMPLEXITY AND MATERIAL QUALITIES.
F. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR THE SPECIAL INSPECTOR. THE
CONSTRUCTION OR WORK FOR WHICH SPECIAL INSPECTION OR TESTING IS REQUIRED
SHALL REMAIN ACCESSIBLE AND EXPOSED FOR SPECIAL INSPECTION OR TESTING
PURPOSES UNTIL COMPLETION OF THE REQUIRED SPECIAL INSPECTION OR TESTING.
G. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING REASONABLE NOTICE TO THE SPECIAL
INSPECTOR(S) REGARDING WHEN ELEMENTS OF THE PROJECT WILL BE READY FOR
EFFICIENT IMPLEMENTATION OF SPECIAL INSPECTIONS.
H. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE LATEST VERSION OF ALL APPROVED
PLANS AND SHOP DRAWINGS FOR THE SPECIAL INSPECTOR'S USE IN PERFORMING
SPECIAL INSPECTIONS.
I. CONTRACTOR SHALL GRANT ACCESS TO OWNER'S SPECIAL INSPECTOR AS IS REASONABLY
NECESSARY FOR THE PROPER PERFORMANCE OF SPECIAL INSPECTIONS.
J. SPECIAL INSPECTIONS DO NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO
COMPLY WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONSTRUCTION MEANS
AND METHODS AND JOBSITE SAFETY ARE SOLELY THE RESPONSIBILITY OF THE
CONTRACTOR.
K. APPROVED SPECIAL INSPECTORS SHALL KEEP RECORDS OF THEIR SPECIAL INSPECTIONS
AND TESTS. THE SPECIAL INSPECTOR SHALL SUBMIT REPORTS OF SPECIAL INSPECTIONS
AND TESTS TO THE BUILDING OFFICIAL AND TO THE REGISTERED DESIGN
PROFESSIONALS IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK
INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO APPROVED
CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE BUILDING OFFICIAL AND TO THE REGISTERED DESIGN PROFESSIONAL
IN RESPONSIBLE CHARGE PRIOR TO THE COMPLETION OF THAT PHASE OF THE WORK. A
FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS, AND
CORRECTION OF DISCREPANCIES SHALL BE SUBMITTED AT A POINT IN TIME AGREED
UPON PRIOR TO THE START OF WORK BY THE OWNER OR OWNER'S AUTHORIZED AGENT TO
THE BUILDING OFFICIAL.
L. SPECIAL INSPECTION OF FABRICATED ITEMS: WHERE FABRICATION OF STRUCTURAL,
LOAD-BEARING OR LATERAL LOAD-RESISTING MEMBERS OR ASSEMBLIES IS BEING
CONDUCTED ON THE PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF
FABRICATED ITEMS SHALL BE PERFORMED DURING FABRICATION. THIS REQUIREMENT MAY
BE WAIVED IF THE EXCEPTIONS OUTLINED BELOW ARE MET.
1) EXCEPTION 1: SPECIAL INSPECTIONS DURING FABRICATION ARE NOT REQUIRED
WHERE THE FABRICATOR MAINTAINS APPROVED DETAILED FABRICATION AND QUALITY
CONTROL PROCEDURES THAT PROVIDE A BASIS FOR CONTROL OF THE WORKMANSHIP
AND THE FABRICATOR'S ABILITY TO CONFORM TO APPROVED CONSTRUCTION
DOCUMENTS AND IBC 2018. APPROVAL SHALL BE BASED UPON REVIEW OF
FABRICATION AND QUALITY CONTROL PROCEDURES AND PERIODIC INSPECTION OF
FABRICATION PRACTICES BY THE BUILDING OFFICIAL.
2) EXCEPTION 2: SPECIAL INSPECTIONS ARE NOT REQUIRED WHERE THE FABRICATOR
IS REGISTERED AND APPROVED IN ACCORDANCE WITH SECTION 1704.2.5.1 OF IBC
2018.
A) FABRICATOR APPROVAL: SPECIAL INSPECTIONS DURING FABRICATION ARE NOT
REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF FABRICATOR
REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL
INSPECTION. APPROVAL SHALL BE BASED UPON REVIEW OF THE FABRICATOR'S
WRITTEN PROCEDURAL AND QUALITY CONTROL MANUALS AND PERIODIC AUDITING
OF FABRICATION PRACTICES BY AN APPROVED AGENCY. AT COMPLETION OF
FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF
COMPLIANCE TO THE OWNER OR OWNER'S AUTHORIZED AGENT FOR SUBMITTAL TO
THE BUILDING OFFICIAL AS SPECIFIED IN SECTION 1704.5 OF IBC 2018
STATING THAT THE WORK WAS APPROVED IN ACCORDANCE WITH THE APPROVED
CONSTRUCTION DOCUMENTS.
M. PER IBC SECTION 1704.3.2, THE SEISMIC FORCE RESISTING SYSTEMS FOR THIS
FACILITY ARE DEFINED IN THE "DESIGN LOADS" SECTION OF THE GENERAL NOTES.
Q. SUBMITTALS TO THE BUILDING OFFICIAL: IN ADDITION TO THE SUBMITTAL OF REPORTS
OF SPECIAL INSPECTIONS AND TESTS IN ACCORDANCE WITH IBC SECTION 1704.2.4,
REPORTS AND CERTIFICATES SHALL BE SUBMITTED BY THE OWNER OR OWNER'S
AUTHORIZED AGENT TO THE BUILDING OFFICIAL FOR EACH OF THE FOLLOWING:
1) CERTIFICATE OF COMPLIANCE FOR THE FABRICATION OF STRUCTURAL,
LOAD-BEARING OR LATERAL LOAD RESISTING MEMBERS OR ASSEMBLIES ON THE
PREMISES OF A REGISTERED AND APPROVED FABRICATOR IN ACCORDANCE WITH IBC
SECTION 1704.2.5.1.
2) CERTIFICATE OF COMPLIANCE FOR THE SEISMIC QUALIFICATION OF NONSTRUCTURAL
COMPONENTS, SUPPORTS AND ATTACHMENTS IN ACCORDANCE WITH IBC SECTION
1705.13.2.
2. REQUIRED SPECIAL INSPECTIONS AND TESTS
A. THE SPECIAL INSPECTOR SHALL PROVIDE CONTINUOUS OR PERIODIC INSPECTIONS AS
SHOWN IN THE ATTACHED INSPECTION TABLES.
1) CONTINUOUS INSPECTION: THE SPECIAL INSPECTOR SHALL BE PRESENT AT ALL
PROCEDURAL EVENTS.
2) PERIODIC INSPECTION: THE SPECIAL INSPECTOR SHALL BE PRESENT AT THE START
OF THE WORK AND PERIODIC INSPECTION IS MADE TO VERIFY PROGRESS OF WORK IS
IN COMPLIANCE.
B. STRUCTURAL STEEL
1) STEEL QUALITY CONTROL AND QUALITY ASSURANCE
A) QUALITY CONTROL (QC) AS SPECIFIED IN AISC 360 CHAPTER N AND SUMMARIZED
HEREIN SHALL BE PROVIDED BY THE FABRICATOR AND ERECTOR.
B) QUALITY ASSURANCE (QA) AS SPECIFIED IN AISC 360 CHAPTER N AND
SUMMARIZED HEREIN SHALL BE PROVIDED BY AN INDEPENDENT INSPECTOR.
C) NONDESTRUCTIVE TESTING (NDT) SHALL BE PERFORMED BY THE AGENCY OR FIRM
RESPONSIBLE FOR QUALITY ASSURANCE (QA).
D) COORDINATED INSPECTION: WHERE A TASK IS NOTED TO BE PERFORMED BY BOTH
QC AND QA, IT IS PERMITTED TO COORDINATE THE INSPECTION FUNCTION
BETWEEN THE QUALITY CONTROL INSPECTOR (QCI) AND QUALITY ASSURANCE
INSPECTOR (QAI) SO THAT THE INSPECTION FUNCTIONS ARE PERFORMED BY ONE
PARTY. THE QAI SHALL PERFORM COORDINATED INSPECTION UNLESS OTHERWISE
AUTHORIZED BY THE EOR AND AHJ.
2) STEEL QUALITY INSPECTOR QUALIFICATIONS
A) QUALITY CONTROL INSPECTOR (QAC) OF ERECTOR/FABRICATOR SHALL BE
QUALIFIED TO THE SATISFACTION OF THE ERECTOR/ FABRICATOR'S QC PROGRAM
AND AISC 360 SECTION N.4.1 REQUIREMENTS.
B) QUALITY ASSURANCE INSPECTOR (QAI) SHALL BE QUALIFIED BY A QA AGENCY
AND AISC 360 SECTION N.4.2 REQUIREMENTS.
C) NON-DESTRUCTIVE TESTING PERSONNEL, OR OTHER THAN VISUAL, SHALL BE
QUALIFIED IN ACCORDANCE WITH EMPLOYER'S WRITTEN PRACTICE MEETING OR
EXCEEDING REQUIREMENTS OF AWS D1.1/D1.1M AND EITHER ANST SNT-TC-1A OR
ANST CP-189 REQUIREMENTS.
3) INSPECTION/APPROVAL OF STEEL FABRICATORS: WHERE FABRICATION OF
STRUCTURAL STEEL LOADBEARING MEMBERS AND ASSEMBLIES IS BEING PERFORMED
ON THE PREMISES OF A STEEL FABRICATOR'S SHOP, REFER TO PARAGRAPH 1.L
ABOVE.
4) REFER ATTACHED TABLES FOR SPECIAL INSPECTIONS AND TESTING FOR STEEL
CONSTRUCTION.
C. CONCRETE CONSTRUCTION
1) SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION SHALL BE
PERFORMED IN ACCORDANCE WITH ITEMS IDENTIFIED IN IBC TABLE 1705.3.
2) IBC SECTION 1705.3, EXCEPTION 1 DOES NOT REQUIRE SPECIAL INSPECTIONS FOR
ISOLATED FOOTINGS OF BUILDINGS LESS THAN THREE STORIES IN HEIGHT THAT
ARE FULLY SUPPORTED ON EARTH OR ROCK. NOTE THAT ALL EMBED POLE
FOUNDATIONS SHALL BE SPECIALLY INSPECTED AND TESTED.
3) COMPRESSIVE STRENGTH TESTS: ASTM C39/C39M
<http://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20C39/C39M>, FOR EACH TEST, MOLD AND CURE FOUR 6X12 CONCRETE TEST CYLINDERS. BREAK 2
CONCRETE TEST CYLINDERS AT 28 DAYS AND HOLD 2 CYLINDERS IN RESERVE FOR
ADDITIONAL TESTING IF INSTRUCTED BY THE DESIGN TEAM. ADDITIONAL
CYLINDERS MAY BE TAKEN FOR EARLY STRENGTH BREAKS AT THE OPTION OF THE
CONTRACTOR. OBTAIN TEST SAMPLES FOR EVERY 100 CUBIC YARDS OR LESS OF
EACH CLASS OF CONCRETE PLACED EACH DAY.
4) PERFORM ONE SLUMP TEST FOR EACH SET OF TEST CYLINDERS TAKEN, FOLLOWING
PROCEDURES OF ASTM C143/C143M
<http://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20C143/C143M>.
5) AIR CONTENT: ASTM C173/C173M
<http://global.ihs.com/doc_detail.cfm?rid=BSD&document_name=ASTM%20C173/C173M>, ONE TEST FOR EACH COMPOSITE SAMPLE, BUT NOT LESS THAN ONE TEST FOR EACH
DAY'S POUR OF EACH CONCRETE MIXTURE.
6) CONCRETE TEMPERATURE: ASTM C1064/C1064M
<https://www.astm.org/Standards/C1064>, ONE TEST HOURLY WHEN AIR
TEMPERATURE IS 40 DEG F AND BELOW OR 80 DEG F AND ABOVE, AND ONE TEST
FOR EACH COMPOSITE SAMPLE.
D. CAST-IN-PLACE DEEP FOUNDATIONS
1) REQUIRED SPECIAL INSPECTIONS AND TESTS ARE AS SHOWN IN TABLE 1705.8 OF
IBC.
Kirkpatrick Forest Curtis PC Structural Engineering
525 Central Park Drive, Suite 202 Oklahoma City, OK 73105
405.528.4596 | kfcengr.com
DATE
PROJECT #
SHEET TITLE
SHEET NUMBER
OK CA #3888, EXP.
S1.0
GENERAL NOTES
O kl ah om a C ity Z oo A nd B ot an ic al
G ar de n
O
KC
E le ph an t S un sh ad e
2/7/2025
20244040
R em in gt on P l, O kl ah om a
C ity
, O K
06/30/25
REVISIONS
No. Date DESCRIPTION
1) GENERAL INFORMATION
A. GOVERNING BUILDING CODE: IBC-2018 "INTERNATIONAL BUILDING CODE" WITH CITY OF
OKLAHOMA CITY AMENDMENTS.
B. BUILDING RISK CATEGORY: THE BUILDING RISK CATEGORY ACCORDING TO IBC-2018
TABLE 1604.5 AND ASCE 7-16 TABLE 1.5-1 IS CATEGORY II.
C. ELEVATIONS: REFERENCE FINISHED FLOOR ELEVATIONS OF 100'-0" EQUALS ACTUAL
EXISTING FINISH GRADE.
D. CONTRACT DOCUMENTS:
1) THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT BETWEEN THE OWNER AND
CONTRACTOR, CONDITIONS OF THE CONTRACT, DRAWINGS, SPECIFICATIONS, ADDENDA
ISSUED PRIOR TO EXECUTION OF THE CONTRACT, OTHER DOCUMENTS LISTED IN THE
AGREEMENT AND MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT.
2) THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND DISSEMINATING ALL
CONTRACT DOCUMENTS AND LATEST ADDENDA TO ALL SUB-CONTRACTORS PRIOR TO
DETAILING, FABRICATION, OR INSTALLATION OF WORK.
3) CORRELATION OF THE CONTRACT DOCUMENTS: THE CONTRACT DOCUMENTS ARE
COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF
REQUIRED BY ALL. IF CONFLICTING REQUIREMENTS ARE FOUND BETWEEN THE
DRAWINGS, SPECIFICATIONS AND/OR THESE GENERAL NOTES, THE MORE STRINGENT
AND HIGHEST COST REQUIREMENT SHALL CONTROL UNLESS DIRECTED OTHERWISE IN
WRITING BY THE OWNER'S REPRESENTATIVE.
4) THE GENERAL CONTRACTOR SHALL COMPARE THE ARCHITECTURAL AND STRUCTURAL
DRAWINGS FOR DISCREPANCIES BETWEEN EACH SET, AND WITHIN EACH SET OF
DRAWINGS, AND REPORT DISCREPANCIES, IF ANY, TO THE OWNER'S REPRESENTATIVE
PRIOR TO THE DETAILING, FABRICATION, AND INSTALLATION OF AFFECTED WORK.
5) GENERAL CONTRACTOR SHALL COORDINATE SIZES AND LOCATIONS OF OPENINGS
THROUGH FLOORS, ROOF, AND WALLS SHOWN ON ELECTRICAL, PLUMBING, AND FIRE
SUPPRESSION SYSTEM DESIGN DOCUMENTS WITH ASSOCIATED SUBCONTRACTORS.
6) ALTHOUGH NOT NECESSARILY SPECIFICALLY REFERENCED IN THE CONTRACT
DOCUMENTS, TYPICAL DETAILS AND GENERAL NOTES APPLY TO THE ENTIRE PROJECT
WHEREVER CONDITIONS SIMILAR TO THOSE DETAILED OR NOTED EXIST.
7) THE USE OF ELECTRONIC FILES OR REPRODUCTION OF CONTRACT DOCUMENTS BY ANY
TRADE OR MATERIAL SUPPLIER IN LIEU OF COMPLETELY INDEPENDENT PREPARATION
OF SHOP DRAWINGS SIGNIFIES THE SUPPLIER'S CERTIFICATION THAT ALL
INFORMATION SHOWN IN THE SHOP DRAWINGS IS CORRECT, AND ASSIGNS THEMSELVES
TO RESPONSIBILITY FOR ANY JOB EXPENSE ARISING DUE TO ANY ERRORS OCCURRING
THEREIN.
E. FIELD MODIFICATIONS: CONTRACTOR OR SUBCONTRACTOR FIELD MODIFICATIONS TO THE
STRUCTURE WITHOUT THE PRIOR WRITTEN CONSENT OF THE STRUCTURAL ENGINEER ARE
EXPRESSLY PROHIBITED AND MAY REQUIRE SUBSEQUENT REMEDIATION DIRECTED BY THE
STRUCTURAL ENGINEER AT CONTRACTOR'S EXPENSE.
2) DESIGN LOADS
A. GOVERNING STANDARD FOR DESIGN LOADS: ASCE 7-16 "MINIMUM DESIGN LOADS FOR
BUILDINGS AND OTHER STRUCTURES"
B. DEAD LOAD: SELF WEIGHT OF MATERIALS, UNLESS NOTED OTHERWISE
C. LIVE LOADS:
1) FABRIC ROOF:.................................................5 PSF
2) ELEPHANT:......................10 KIPS AT 7'-0" ABOVE FINISH GRADE
D. WIND LOADS:
1) RISK CATEGORY: .................................................II
2) EXPOSURE CATEGORY:...............................................C
3) ENCLOSURE CLASSIFICATION..................................ENCLOSED
4) INTERNAL PRESSURE COEFFICIENT, GCPI:....... ..............+/- 0.18
5) TOPOGRAPHIC FACTOR, KZT:.......................................1.0
6) DIRECTIONALITY FACTOR, KD:....................................0.85
7) ULTIMATE DESIGN WIND SPEED, Vult:..........................109 MPH
8) NOMINAL DESIGN WIND SPEED, Vasd:............................90 MPH
9) FABRIC DESIGN WIND PRESSURE:..............................30.0 PSF
E. SNOW LOADS:
1) SNOW IMPORTANCE FACTOR, Is:....................................1.0
2) GROUND SNOW LOAD, Pg:.......................................10 PSF
3) EXPOSURE OF ROOF: ...............................PARTIALLY EXPOSED
4) SURFACE ROUGHNESS CATEGORY:......................................C
5) EXPOSURE FACTOR, Ce:...........................................1.0
6) THERMAL FACTOR, Ct:............................................1.2
7) ROOF SLOPE FACTOR, Cs:.........................................1.0
8) CALCULATED FLAT ROOF SNOW LOAD, Pf:........................8.4 PSF
9) MINIMUM FLAT ROOF SNOW LOAD, I*Pg:........................13.4 PSF
F. ICE LOADS:
1) ICE IMPORTANCE FACTOR, Ii:.....................................1.0
2) NOMINAL ICE THICKNESS, t:..................................1.50 IN
3) DESIGN ICE THICKNESS, td:..................................1.48 IN
4) UNIFORM ICE LOAD:.........................................13.0 PSF
5) ULTIMATE DESIGN WIND ON ICE SPEED, Vult:....................40 MPH
G. RAIN LOADS:
1) 15-MINUTE RAIN INTENSITY..........................7.81 INCHES/HOUR
2) 60-MINUTE RAIN INTENSITY..........................3.94 INCHES/HOUR
H. SEISMIC DESIGN CRITERIA:
1) RISK CATEGORY: .................................................II
2) SEISMIC IMPORTANCE FACTOR, Ie:................................1.00
3) SOIL SITE CLASSIFICATION (ASSUMED):..............................D
4) 0.2 SEC. MAPPED SPECTRAL ACCELERATION, Ss:...................0.298
5) 1.0 SEC. MAPPED SPECTRAL ACCELERATION, S1:...................0.080
6) SITE COEFFICIENT, 0.2 SEC. PERIOD, Fa:.......................1.562
7) SITE COEFFICIENT, 1.0 SEC. PERIOD, Fv:.....................