Attachment_One_Task_1_Inspection_Services.docx
DOCX document 12 KB Posted
- Solicitation number
- M00264-18-T-4321
- Issued by
-
United States Marine Corps
About this file
Attachment One_Task 1 Inspection Services
View the file
Other files
| File | Type | Posted |
|---|---|---|
| M00264-18-T-4321_Amendment_00001.pdf | ||
| FERV_PO_Price_Template.xlsx | XLSX spreadsheet | |
| M00264-18-T-4321_final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment One: Task 1: Inspection Services The Apparatus listed below will require the following annual inspections and/or testing required by NFPA 1911 Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Emergency Vehicles. Inspections and/or testing needs to be completed by persons who meet the requirements set forth by NFPA 1071 Standard for Emergency Vehicle Technician Professional Qualifications.
1994 Pierce Arrow Pumper (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 1992/2007 105’ Pierce Arrow XT Aerial (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 22 Performance Testing of Aerial Devices, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 1994 Pierce Arrow Pumper (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2000 Pierce Sabre Pumper (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2005 Kenworth/Pierce Encore HazMat (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2001 International/Pierce Fire Hawk (NFPA 1911, Chapter 18 Inspection and Maintenance of Winch Systems, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2001 EONE Cyclone II HP 75’ Aerial (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 22 Performance Testing of Aerial Devices, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2009 Pierce Impel Pumper (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2013 Pierce Velocity 75’ Aerial (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 22 Performance Testing of Aerial Devices, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems) 2014 Pierce Saber Pumper (NFPA 1911, Chapter 19 Road Tests and Annual Weight Verification, Chapter 20 Performance Testing of Low-Voltage Electrical Systems, Chapter 21 Performance Testing of Fire Pumps, Chapter 23 Performance Testing of Foam Proportioning Systems, Chapter 25 Performance Testing of Line Voltage Electrical Systems)
File details come from the government source that posted it.