This document is a comprehensive line-item pricing schedule for Garland/DBS roofing contract 190-25, detailing an indefinite delivery vehicle for roofing, waterproofing, restoration, and related construction services. The contract appears to be a state and local government contract that provides detailed pricing for various roofing system installations, repairs, and maintenance across multiple roof types, deck substrates, and material configurations.

The pricing schedule covers an extensive range of roofing services, including tear-off and disposal, deck replacement, insulation options, roof system installations (built-up, modified, single-ply, metal, shingle), restoration techniques, wall coatings, flashings, and miscellaneous accessories. Pricing is provided per square foot or unit, with options for different materials like EPDM, TPO, PVC, aluminum, galvalume, stainless steel, and copper panels. The contract includes multiple warranty options, with coverage periods ranging from 15 to 30 years, and provisions for different wind uplift pressures. Additional multipliers are provided for job-specific conditions such as roof access difficulty, working hours, roof height, and project size, allowing for flexible pricing adaptation to specific project requirements.

View the file

Other files

File Type Posted
Signature.pdf PDF
Garland_DBS_Material_Price_File_190-25.xlsx XLSX spreadsheet
ODOT_Co-Op_Program_Information.pdf PDF
190-25_Bid_Document.pdf PDF
190-25_Garland_Pricing_2024-11-14.xlsx XLSX spreadsheet
Affirmation_and_Disclosure_Signed__1_.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Systems

190-25 Roofing
Line ItemUnit$ per Unit
1.00Roof Management, Design Assistant and/or Professional Services
1.01Full-time Quality Assurance monitoringDAY882.00
1.02Asbestos core testing and analysis (testing only, excludes labor for sampling and repair)EA110.25
1.03Analysis and evaluation (14” x 14” roof core) (Lab testing only, repairs charged at roof repair rates for appropriate system type)EANSP
1.04Aerial Roof Survey - Roof Pictures & Drawings Including Geometries, Slope, Calculated Area and Perimeter MeasurementsEANSP
1.05Aerial Wall Survey - Wall Pictures & Drawings Including Geometries, Calculated Area and Perimeter MeasurementsEANSP
1.06Manufacturer Standing Seam Material Quantity EstimatingEANSP
1.07Nuclear Moisture Survey, Non destructive roof scan
1.07.01Non destructive roof scan, up to 20 000 SFEA3,150.00
1.07.02Non destructive roof scan, over 20,000 SFSF0.14
1.08Infrared Moisture Scanning
1.08.01Non destructive infrared roof scan, up to 20 000 SFEA2,047.50
1.08.02Non destructive infrared roof scan, over 20,000 SFSF0.09
1.08.03Aerial infrared roof scan at nightTRIP2,388.75
1.09Infrared scanning equipment rentalDAYNSP
1.10Roof investigation (visual roof survey)
1.10.01Roof Investigation (Roof by Roof), per hourHOURNSP
1.10.02Visual Roof Survey (Roof by Roof) up to 20,000 SFEANSP
1.10.03Visual Roof Survey (Roof by Roof) over 20,000 SFSFNSP
1.10.04Visual Roof Survey (Single Campus - All Roof Sections)SF0.08
1.10.05Visual Roof Survey (Multiple Campuses City-/County-wide - All Roof Sections)SF0.14
1.10.06Visual Roof Survey (Multiple Campuses State-wide - All Roof Sections)SF0.14
1.10.07Roof core cut (roof by roof)EANSP
1.10.08Roof core cut per roof section (all roof sections on campus(s))EA204.75
1.11Comprehensive reporting
1.11.01Comprehensive report for visual survey (Roof by Roof)EANSP
1.11.02Comprehensive report for visual survey(All Roof Sections on Campus(es)EA136.50
1.11.03Comprehensive report for each roof section(s) surveyed (Item 1.07) or scanned (Item 1.08)EA341.25
1.11.04Comprehensive report enertered into on-line data base for dynamic reporting and tracking all roofing sections on Campus(s)EANSP
1.12Manufacturer's Technical Representative Contractor Training Session at Job Start-UpDAILYNSP
1.13Wind Uplift Testing – Mobilize and provide wind uplift testing per Factory Mutual System Roof Design Manual FM 1-52EANSP
1.14Roof drawings to scale with all rooftop equipment and penetrations
1.14.01Roof drawings (Roof by Roof)EANSP
1.14.02Roof drawings (All Roof Sections on Campus(es)EA118.13
1.15Project Building Code ReviewEANSP
1.16Additional and Occasional Services
1.16.01Project Architect for Design Professional ServicesHOUR170.63
1.16.02Principle Architect for Design Professional ServicesHOUR238.88
1.16.03Project Engineer for Engineering ReviewsHOUR170.63
1.16.04Principle Architect for Engineering ReviewsHOUR238.88
1.16.06Roof ConsultantHOUR170.63
1.16.07Full-Time Job Site SuperintendentDAY819.00
1.16.08CAD DraftsmanHOUR102.38
1.17Laboratory Analysis
1.17.01Laboratory Fungal Analysis: Cultured Fungi Identification & Enumeration (Not including engineering time for sampling)EA443.63
1.17.02Laboratory Fungal Analysis: Total Fungi Spore Count (Not including engineering time for sampling)EA443.63
1.17.03Laboratory Mold Analysis: Viable Airborne Mold Analysis (Not including engineering time for sampling)EA443.63
1.17.04Laboratory Analysis: Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling)EA443.63
1.17.05Laboratory Analysis: Non-Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling)EA443.63
1.17.06Destructive Roof Sample Analysis:
Comprehensive laboratory testing of a core sample from an existing roof to include tensile/tear strength, scrim type, interply bitumen weight and roof composition; Repair the roof core area with similar materials.EANSP
1.18Travel Expenses
1.18.01Per Diem – Meals and IncidentalsDAYNSP
1.18.02LodgingDAYNSP
1.18.03Mileage on Company / Personal VehicleMILENSP
1.18.04Airfare (Economy)JOBNSP
1.18.05Vehicle RentalDAYNSP
1.19Seamer Rental ChargesDAYNSP
1.20Set-up Charges for Metal In-Shop FabricationEANSP
1.21Set-up On-Site Roll FormingEANSP
1.22Roof Fastener Pull Tests (As Many as Required per Roof Section)EANSP
1.23Wind Uplift Design CalculationsEANSP
1.24Roof Drainage Capacity CalculationsEANSP
1.25Roof Edge Metal Calculations - ANSI/SPRI ES-1 StandardsEANSP
1.26Dew Point CalculationsEANSP
1.27Energy Payback CalculationsEANSP
1.28Project Life-Cycle Cost CalculationEANSP
1.29Substantial Completion Walkthrough with Report and PunchlistEANSP
1.30Final Walkthrough with ReportEANSP
1.31On-Site Quality Control Inspections with Report from Manufacturer's Rep - 3 Days per WeekWEEKNSP
1.32"As-Built" Drawings Upon Project CompletionEANSP
1.33R.A. or P.E. Reviewed and Stamped Shop DrawingsEANSP
1.34R.A. or P.E. Reviewed and Stamped SpecificationsEANSP
1.35Non-R.A./P.E. Reviewed Shop DrawingsEANSP
1.36Project Design Assistance - Hourly Rate for Consultations with Architect of RecordEANSP
1.37Project Design Assistance - Development of a recommended specification for a roofing or waterproofing projectEANSP
1.38Roof Asset Management Report with recommended options for future course of actions and associated budgets for capital expense and maintenance planning.EANSP
1.39Five year capital expense and maintenance plan ( All roof section on for campus(es))EANSP
1.40Additional Professional Services
1.40.01Option 1: Professional Services (Third party architectural design, engineering or consulting services quote on corporate letterhead)
Cost plus added to quote%14%
1.40.02Option 2: R.S. Means or Gordian Group Catalog (Used when professional services line item pricing is not available)
Cost plus added to catalog pricing%14%
2.00Tear-off & Dispose of Debris
2.01SYSTEM TYPE
BUR W/ Insulation and Gravel Surfacing - Metal DeckSF3.96
2.02SYSTEM TYPE
BUR W/ Insulation and Gravel Surfacing - Wood / Tectum DeckSF3.96
2.03SYSTEM TYPE
BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp DeckSF3.96
2.04SYSTEM TYPE
BUR W/ Insulation and Gravel Surfacing - Concrete DeckSF3.96
2.05SYSTEM TYPE
BUR W/ Insulation and Mineral Surfacing - Metal DeckSF3.70
2.06SYSTEM TYPE
BUR W/ Insulation and Mineral Surfacing - Wood / Tectum DeckSF3.70
2.07SYSTEM TYPE
BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp DeckSF3.70
2.08SYSTEM TYPE
BUR W/ Insulation and Mineral Surfacing - Concrete DeckSF3.70
2.09SYSTEM TYPE
Single-Ply W/ Insulation - Metal DeckSF2.99
2.10SYSTEM TYPE
Single-Ply W/ Insulation - Wood / Tectum DeckSF2.99
2.11SYSTEM TYPE
Single-Ply W/ Insulation - Lightweight / Gyp DeckSF2.99
2.12SYSTEM TYPE
Single-Ply W/ Insulation - Concrete DeckSF2.99
2.13SYSTEM TYPE
Ballasted Single-Ply W/ Insulation - Metal DeckSF4.29
2.14SYSTEM TYPE
Ballasted Single-Ply W/ Insulation - Wood / Tectum DeckSF4.29
2.15SYSTEM TYPE
Ballasted Single-Ply W/ Insulation - Lightweight / Gyp DeckSF4.29
2.16SYSTEM TYPE
Ballasted Single-Ply W/ Insulation - Concrete DeckSF4.29
2.17SYSTEM TYPE
Coal Tar BUR W/ Insulation and Gravel Surfacing - Metal DeckSF4.43
2.18SYSTEM TYPE
Coal Tar BUR W/ Insulation and Gravel Surfacing - Wood / Tectum DeckSF4.43
2.19SYSTEM TYPE
Coal Tar BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp DeckSF4.43
2.20SYSTEM TYPE
Coal Tar BUR W/ Insulation and Gravel Surfacing - Concrete DeckSF4.43
2.21SYSTEM TYPE
Coal Tar BUR W/ Insulation and Mineral Surfacing - Metal DeckSF4.17
2.22SYSTEM TYPE
Coal Tar BUR W/ Insulation and Mineral Surfacing - Wood / Tectum DeckSF4.17
2.23SYSTEM TYPE
Coal Tar BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp DeckSF4.17
2.24SYSTEM TYPE
Coal Tar BUR W/ Insulation and Mineral Surfacing - Concrete DeckSF4.17
2.25SYSTEM TYPE
Metal Roofing or Metal Wall Panel System - Metal DeckSF4.00
2.26SYSTEM TYPE
Metal Roofing or Metal Wall Panel System - Metal Deck - Wood / Tectum DeckSF4.00
2.27SYSTEM TYPE
Metal Roofing or Metal Wall Panel System - Metal Deck - Lightweight / Gypsum DeckSF4.00
2.28SYSTEM TYPE
Metal Roofing or Metal Wall Panel System - Metal Deck - Concrete DeckSF4.00
2.29SYSTEM TYPE
Dimensional/Architectural Shingle Roof - Wood DeckSF1.62
2.30SYSTEM TYPE
3-Tab Shingle Roof - Wood DeckSF1.62
2.31SYSTEM TYPE
Clay Tile Shingle Roof - Wood DeckSF4.32
2.32SYSTEM TYPE
Concrete Tile Shingle Roof - Wood DeckSF4.32
2.33SYSTEM TYPE
Slate Tile Shingle Roof - Wood DeckSF4.90
2.34SYSTEM TYPE
Cedar / Wood Shake Shingle Roof - Wood DeckSF4.32
2.35SYSTEM TYPE
Add to save good Clay Tile Shingles for reuseSF1.26
2.36SYSTEM TYPE
Add to save good Concrete Tile Shingles for reuseSF1.26
2.37SYSTEM TYPE
Add to save good Slate Tile Shingles for reuseSF1.26
2.38SYSTEM TYPE
Add to save good Cedar / Wood Shake Shingles for reuseSF2.59
2.39SYSTEM TYPE
Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Metal DeckSF4.20
2.40SYSTEM TYPE
Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Wood / Tectum DeckSF4.20
2.41SYSTEM TYPE
Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Lightweight / Gyp DeckSF4.20
2.42SYSTEM TYPE
Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Concrete DeckSF4.20
2.43SYSTEM TYPE
Add of Each Additional Average Depth 1" of Polyurethane Foam (PUF) RoofingSF1.60
2.44SYSTEM TYPE
BUR w/ Gravel Surfacing to the Existing Insulation (Insulation to be Re-Used)SF4.00
2.45SYSTEM TYPE
BUR w/ Mineral Surfacing to the Existing Insulation (Insulation to be Re-Used)SF3.96
2.46SYSTEM TYPE
Single-Ply to the Existing Insulation (Insulation to be Re-UsedSF3.21
2.47SYSTEM TYPE
Ballasted Single-Ply to the Existing Insulation (Insulation to be Re-UsedSF2.50
2.48SYSTEM TYPE
Coal Tar BUR with Gravel Surfacing to the Existing Insulation (Insulation to be Re-Used)SF4.64
2.49SYSTEM TYPE
Coal Tar BUR with Mineral Surfacing to the Existing Insulation (Insulation to be Re-Used)SF4.64
2.99MULTIPLIER - TEAR-OFF & DISPOSE OF DEBRIS
Each Additional Roof System%44%
3.00Removal & Replacement of Roof Deck
3.01DECK TYPE
Spot Metal Deck Replacement (Multiple areas under 1 square)SF23.16
3.02DECK TYPE
Spot Wood Deck Replacement (Multiple areas under 1 square)SF21.19
3.03DECK TYPE
Spot Gypsum Deck Replacement (Multiple areas under 1 square)SF67.57
3.04DECK TYPE
Spot Concrete Deck Replacement (Multiple areas under 1 square)SF51.79
3.05DECK TYPE
Spot Lightweight Deck Replacement (Multiple areas under 1 square)SF30.01
3.06DECK TYPE
Spot Tectum Deck Replacement (Multiple areas under 1 square)SF28.75
3.07DECK TYPE
Large Areas of Metal Deck Replacement (Replacement areas averaging greater than 1 square)SF14.39
3.08DECK TYPE
Large Areas of Wood Deck Replacement (Replacement areas averaging greater than 1 square)SF15.25
3.09DECK TYPE
Large Areas of Gypsum Deck Replacement (Replacement areas averaging greater than 1 square)SF55.39
3.10DECK TYPE
Large Areas of Concrete Deck Replacement (Replacement areas averaging greater than 1 square)SF42.44
3.11DECK TYPE
Large Areas of Lightweight Deck Replacement (Replacement areas averaging greater than 1 square)SF22.56
3.12DECK TYPE
Large Areas of Tectum Deck Replacement (Replacement areas averaging greater than 1 square)SF23.00
4.00Insulation Recovery Board & Insulations Options
4.01RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; MoppedSF1.52
4.02RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered with Insulation AdhesiveSF2.91
4.03RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Metal DeckSF1.54
4.04RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Wood / Tectum DeckSF1.66
4.05RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Lightweight / Gypsum DeckSF1.70
4.06RECOVERY BOARD TYPE
1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Concrete DeckSF1.74
4.07RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; MoppedSF2.65
4.08RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Adhered with Insulation AdhesiveSF3.89
4.09RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Metal DeckSF2.69
4.10RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Wood / Tectum DeckSF2.93
4.11RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Lightweight / Gypsum DeckSF2.99
4.12RECOVERY BOARD TYPE
1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Concrete DeckSF3.09
4.13ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF)
Install 1.0" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of InsulationSF2.74
4.14ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF)
Install 1.5" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of InsulationSF2.95
4.15ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF)
Install 2.0" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of InsulationSF3.45
4.16ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF)
Install 2.5" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of InsulationSF3.97
4.17ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF)
Add for Cutting New Insulation to Match the Profile of an Existing Metal Roof.SF1.97
4.18INSULATION SUBSTITUTION OPTION
Deduct for Providing an R-Value of greater than or equal to 10, but less than 15; instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof SystemsSF-0.83
4.19INSULATION SUBSTITUTION OPTION
Deduct for Providing an R-Value of greater than or equal to 15, but less than 18; instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof SystemsSF-0.49
4.20INSULATION SUBSTITUTION OPTION:
Deduct for Providing an R-Value of greater than or equal to 18, but less than 20 instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof SystemsSF-0.23
4.21INSULATION SUBSTITUTION OPTION:
Add for Providing an R-Value of 25 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof SystemsSF0.89
4.22INSULATION SUBSTITUTION OPTION:
Add for Providing an R-Value of 30 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof SystemsSF1.81
4.23INSULATION SUBSTITUTION OPTION
Substitute 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Place of the Wood Fiber or Perlite - Adhered in Hot ASTM D 312 Type III or IV Asphalt; MoppedSF1.11
4.24INSULATION SUBSTITUTION OPTION
Substitute 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Place of the Wood Fiber or Perlite - Adhered with Insulation AdhesiveSF1.11
4.25INSULATION SLOPE OPTION
Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered Crickets; Adhered in ASTM D 312 Type III or IV Hot Asphalt; MoppedSF10.11
4.26INSULATION SLOPE OPTION
Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered in ASTM D 312 Type III or IV Hot Asphalt; MoppedSF7.22
4.27INSULATION SLOPE OPTION
Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered Crickets; Adhered with Insulation AdhesiveSF16.38
4.28INSULATION SLOPE OPTION
Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered with Insulation AdhesiveSF11.51
4.29INSULATION SUBSTITUTION OPTION
Provide a 1/4" Tapered Insulating Lightweight Concrete System while Maintaining Average R-ValueSF12.58
4.30INSULATION SUBSTITUTION OPTION
Provide a 1/8" Tapered Insulating Lightweight Concrete System while Maintaining Average R-ValueSF11.67
4.31INSULATION ATTACHMENT OPTION:
Provide Attachment Pattern in Compliance with FM 1-60 Wind Uplift Instead of FM 1-90SF-0.04
4.32INSULATION ATTACHMENT OPTION:
Provide Attachment Pattern in Compliance with FM 1-120 Wind Uplift Instead of FM 1-90SF0.24
5.00Coat New Roofing With Elastomeric Coating
5.01ROOF SYSTEM TYPE
Apply an Acrylic Coating per Specifications (1.5 Gallons per Square per Coat - 2 Coats Required) - Mineral-Surfaced Modified RoofSF6.04
5.02ROOF SYSTEM TYPE
Apply an Acrylic Coating per Specifications (1.0 Gallon per Square per Coat - 2 Coats Required) - Smooth-Surfaced Modified RoofSF4.69
5.03ROOF SYSTEM TYPE
Apply a bright white, water-based, acrylic-urethane hybrid roof coating per Specifications (1.5 Gallons per Square per Coat - 2 Coats Required) - Mineral-Surfaced Modified RoofSF8.04
5.04ROOF SYSTEM TYPE
Apply a bright white, water-based, acrylic-urethane hybrid roof coating per Specifications (1.0 Gallon per Square per Coat - 2 Coats Required) - Smooth-Surfaced Modified RoofSF5.97
5.05ROOF SYSTEM TYPE
Apply an Acrylic base coat and a PVDF top coat per Specifications (1.5 Gallons per Square Base Coat - 1/2 Gallon per Square Top Coat) - Mineral-Surfaced Modified RoofSF7.47
5.06ROOF SYSTEM TYPE
Apply an Acrylic base coat and a PVDF top coat per Specifications (1 Gallon per Square Base Coat - 1/2 Gallon per Square Top Coat) -Smooth-Surfaced Modified RoofSF6.55
5.07ROOF SYSTEM TYPE
Apply an Urethane Coating per Specifications (1 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral Surfaced Modified; With Reinforced Seams (Base Coat Seam with 1.5 Gallons per Square & Reinforcement)SF13.94
5.08ROOF SYSTEM TYPE
Apply a single-component, aliphatic, polyurea liquid adhesive per Specifications (Apply 1.0 gallon per Square on Seams & wait 24 Hours / Apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 200 lbs. per Square / wait 24 hours and apply top coat at 1.0 gallon per Square - Mineral-Surfaced ModifiedSF12.02
5.09ROOF SYSTEM TYPE
Apply a single-component, aliphatic, polyurea liquid adhesive per Specifications (apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 200 lbs. per Square / wait 24 hours and apply top coat at 1.0 gallon per Square - Smooth-Surfaced ModifiedSF12.02
5.10ROOF SYSTEM TYPE
Apply an Aluminum Coating per Specifications (3/4 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral Surfaced ModifiedSF3.27
5.11ROOF SYSTEM TYPE
Apply a Fibered Aluminum Coating per Specifications (2 Gallons per Square per Coat - 1 Coat Required) - Smooth or Mineral Surfaced ModifiedSF3.97
6.00Roof Deck and Insulation Option
6.01METAL ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT
6.01.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20
In Compliance with FM 1-90 RequirementsSF5.62
6.02WOOD ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT
6.02.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20SF5.30
6.02.02INSULATION OPTION:Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base SheetSF1.75
6.03TECTUM ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT
6.03.01INSULATION OPTION:Mechanically Attach Base Sheet Utilizing FM 1-90 Attachment Patterns & Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20SF9.19
6.03.02INSULATION OPTION:Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base SheetSF2.54
6.04LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT
6.04.01INSULATION OPTION:Must Mechanically Attach a Base Sheet; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF9.19INSULATION OPTION: Must Mechanically Attach a Base Sheet; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20

In Compliance FM 1-90 Requirements

6.04.02INSULATION OPTION:Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation
Installed with FM 1-90 Attachment PatternsSF2.54
6.05CONCRETE ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT
6.05.01INSULATION OPTION:Prime Roof Deck; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF6.15
6.05.02INSULATION OPTION:Without Insulation - Prime Roof Deck; Must at Least 1/2" Wood Fiber or Perlite Hot Mopped to Deck
In Compliance FM 1-90 RequirementsSF1.52
6.06METAL ROOF DECK - COLD PROCESS APPLICATION
6.06.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF6.27
6.07WOOD ROOF DECK - COLD PROCESS APPLICATION
6.07.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20SF6.27
6.07.02INSULATION OPTION:Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base SheetSF1.75
6.08TECTUM ROOF DECK - COLD PROCESS APPLICATION
6.08.01INSULATION OPTION:Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20SF12.54
6.08.02INSULATION OPTION:Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base SheetSF2.56
6.09LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - COLD PROCESS APPLICATION
6.09.01INSULATION OPTION:Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF12.54
6.09.02INSULATION OPTION:Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck
Installed with FM 1-90 Attachment PatternsSF2.56
6.10CONCRETE ROOF DECK - COLD PROCESS APPLICATION
6.10.01INSULATION OPTION:Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF9.27
6.10.02INSULATION OPTION:Without Insulation - Must at Least 1/2" High Density Asphalt Coated Wood Fiber Adhered with Insulation Adhesive to Deck
In Compliance FM 1-90 RequirementsSF2.23
6.11METAL ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION
6.11.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF7.08
6.12WOOD ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION
6.12.01INSULATION OPTION:Mechanically Fasten Polyisocyanurate / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20SF7.08
6.12.02INSULATION OPTION:Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal)SF1.76
6.13TECTUM ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION
6.13.01INSULATION OPTION:Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20SF13.15
6.13.02INSULATION OPTION:Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal)SF2.60
6.14LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION
6.14.01INSULATION OPTION:Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF13.15
6.14.02INSULATION OPTION:Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation
Installed with FM 1-90 Attachment PatternsSF2.60
6.15CONCRETE ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION
6.15.01INSULATION OPTION:Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20
In Compliance FM 1-90 RequirementsSF9.85
6.15.02INSULATION OPTION:Without Insulation - Must Adhere 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive
In Compliance FM 1-90 RequirementsSF2.95
6.16INSTALL PRIOR TO ROOF SYSTEM INSULATION:
6.16.01VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK:

Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal), Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt

In Compliance with FM 1-90 RequirementsSF3.99
6.16.02VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt
In Compliance with FM 1-90 RequirementsSF4.13
6.16.03VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK:
Prime Deck Prior to Applying 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV AsphaltSF2.75
6.16.04VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK:

Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); Apply 2 Plies of Glass Base in Cold Process Modified Asphalt

In Compliance with FM 1-90 RequirementsSF6.30
6.16.05VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Base in Cold Process Modified Asphalt
In Compliance with FM 1-90 RequirementsSF6.30
6.16.06VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK:
Prime Deck Prior to Applying 2 Plies of Glass Base in Cold Process Modified AsphaltSF4.89
6.16.07VAPOR BARRIER OPTION:TORCH-APPLIED VAPOR BARRIER ON METAL DECK:

Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); Heat Weld with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147)

In Compliance with FM 1-90 RequirementsSF6.92
6.16.08VAPOR BARRIER OPTION:TORCH-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Heat Weld with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147)
In Compliance with FM 1-90 RequirementsSF7.14
6.16.09VAPOR BARRIER OPTION:TORCH-APPLIED VAPOR BARRIER ON CONCRETE DECK:
Prime Deck Prior to Heat Welding with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147)SF5.73
6.16.10VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK:

Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal), ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt

In Compliance with FM 1-90 RequirementsSF5.30
6.16.11VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt
In Compliance with FM 1-90 RequirementsSF5.69
6.16.12VAPOR BARRIER OPTION:HOT ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK:
Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV AsphaltSF4.18
6.16.13VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK:

Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified Asphalt

In Compliance with FM 1-90 RequirementsSF6.55
6.16.14VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified Asphalt
In Compliance with FM 1-90 RequirementsSF6.51
6.16.15VAPOR BARRIER OPTION:COLD ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK:
Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified AsphaltSF5.11
7.00BUILT-UP MODIFIED ROOF WITH FLOOD COAT AND AGGREGATE IN HOT ASTM D 312 TYPE III OR IV ASPHALT
7.01ROOF CONFIGURATION

2 Plies of Glass Felt, Cap Sheet, Flood Coat and Aggregate All in Hot ASTM D 312 Type III OR IV Asphalt

7.01.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF8.48
7.01.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF10.25
7.01.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF10.12
7.01.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensileSF11.67
7.01.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensileSF12.31
7.02WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 7.00
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
7.03WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP
7.04WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
7.05WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
7.06DEDUCT TO SQUARE FOOT COST - Hot Applied Modified BUR
Substitute Additional Glass Felt (Hot Applications) in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile (i.e. 3 Ply BUR)SF3.17
7.07ADD TO PER SQUARE FOOT COST - Hot Applied Modified BUR
Each Additional Glass Felt (Hot Applications) Inter-ply InstalledSF1.13
8.00BUILT-UP MODIFIED ROOF WITH FLOOD COAT AND AGGREGATE IN COLD PROCESS ASPHALT
8.01ROOF CONFIGURATION

2 Plies of Glass Base, Cap Sheet, Flood Coat and Aggregate All in Cold Process Modified Asphalt

8.01.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF14.00
8.01.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF15.95
8.01.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF15.84
8.01.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensileSF17.38
8.01.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensileSF18.00
8.02WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 8.00
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
8.03WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP
8.04WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
8.05WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
8.06DEDUCT TO SQUARE FOOT COST - Cold Applied Modified BUR
Substitute Additional Glass Base Sheet in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile (i.e. 3 Ply BUR)SF-1.74
8.07ADD TO PER SQUARE FOOT COST - Cold Applied Modified BUR
Each Additional Glass Base (Cold Applications) Inter-ply InstalledSF2.60
9.00BUILT-UP MODIFIED ROOF ADHERED IN HOT ASTM D 312 TYPE III OR IV ASPHALT - FLOOD COAT & AGGREGATE IN MODIFIED COAL TAR PITCH
9.01ROOF CONFIGURATION

2 ply of Glass Felt, Cap Sheet, Set in Hot Asphalt, Flood Coat in Modified Coal Tar Pitch and Aggregate

9.01.01ROOFING MEMBRANE & COATING OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF12.38
9.01.02ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF14.14
9.01.03ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF14.04
9.01.04ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF15.56
9.01.05ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF16.20
9.02WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 9.00
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
9.03WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP
9.04WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
9.05WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
9.06COATING OPTION:Add/Deduct for Installing Flood Coat in Cold Process Coal Tar PitchSF-0.64
10.00BUILT-UP MODIFIED ROOF WITH MINERAL CAP SHEET ADHERED IN HOT ASTM D 312 TYPE III OR IV ASPHALT
10.01ROOF CONFIGURATION

2 ply of Glass Felt, Mineral Surfaced Cap Sheet, Set in Hot ASTM D 312 Type III or IV Asphalt

10.01.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF7.02
10.01.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF9.20
10.01.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF8.37
10.01.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensileSF10.59
10.01.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensileSF11.61
10.02WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 10.00
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
10.03WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-3
10.04WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
10.05WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
11.00BUILT-UP MODIFIED ROOF WITH MINERAL CAP SHEET ADHERED IN COLD PROCESS ASPHALT
11.01ROOF CONFIGURATION

2 ply Glass Base, Mineral Cap Sheet, Set in Cold Process Modified Asphalt

11.01.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF10.89
11.01.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF13.05
11.01.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF12.21
11.01.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensileSF14.43
11.01.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensileSF15.48
11.02WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 11.00
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
11.03WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-3
11.04WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
11.05WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
12.002-PLY ROOF SYSTEMS - COMBINATIONS OF A BASE PLY & A CAP SHEET (TOP PLY)

PLEASE NOTE: BASE PLY & CAP SHEET COMBINATIONS MUST BE APPROVED BY THE MANUFACTURER

12.01 ROOF CONFIGURATION

1 Ply Modified Base Sheet Adhered in Hot ASTM D 312 Type III or IV Asphalt

12.01.01BASE PLY OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensileSF3.90
12.01.02BASE PLY OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 lbf/in tensileSF4.96
12.01.03BASE PLY OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 lbf/in tensileSF5.15
12.01.04ADD/DEDUCT TO PER SQUARE FOOT COST - Hot Applied Modified Multi-ply Systems
Each Additional Modified Base Sheet (All Hot Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.01.02 + 12.01.02 + 12.01.04 = Two Plies Installed)SF-0.46
12.02ROOF CONFIGURATION

1 Ply Modified Base Sheet Adhered in Cold Process Modified Asphalt

12.02.01BASE PLY OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensileSF4.90
12.02.02BASE PLY OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 lbf/in tensileSF5.95
12.02.03BASE PLY OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 lbf/in tensileSF6.16
12.02.04ADD/DEDUCT TO PER SQUARE FOOT COST - Cold Applied Modified Multi-ply Systems
Each Additional Modified Base Sheet (All Cold Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.02.02 + 12.02.02 + 12.02.04 = Two Plies Installed)SF-0.54
12.02.05INTERPLY ADHESIVE OPTION:Add/Deduct for Cold Applied Modified Multi-ply Systems
Substitute Cold Process Adhesive with Alternative Solvent Free AdhesiveSF2.63
12.03ROOF CONFIGURATION

1 Ply of Torch Base Sheet Installed with Torch Application

12.03.01BASE PLY OPTION:SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147)SF4.35
12.03.02BASE PLY OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 210 lbf/in tensileSF5.79
12.03.03ADD/DEDUCT TO PER SQUARE FOOT COST - Torch-Applied Modified Multi-ply Systems
Each Additional Modified Base Sheet (All Torch-Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.03.02 + 12.03.02 + 12.03.03 = Two Plies Installed)SF-0.29
12.04ROOF CONFIGURATION

1 Ply of Self-Adhering Base Installed Using Self-Adhering Backing

12.04.01BASE PLY OPTION:SBS Modified Asphalt-Based, Polyester OR Fiberglass/Polyester OR Fiberglass Reinforced Self-Adhering Base Sheet - Minimum of 50 lbf/in tensileSF4.44
12.04.02ADD/DEDUCT TO PER SQUARE FOOT COST - Torch-Applied Modified Multi-ply Systems
Each Additional Modified Base Sheet (All Torch-Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.04.01 + 12.04.01 + 12.04.02 = Two Plies Installed)SF-0.29
12.05ROOF CONFIGURATION

1 Ply Cap Sheet, Flood Coat and Aggregate Adhered in Hot ASTM D 312 Type III OR IV Asphalt

12.05.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF4.90
12.05.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF6.85
12.05.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF6.74
12.05.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III – Minimum of 500 lbf/in tensileSF8.27
12.05.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III – Minimum of 600 lbf/in tensileSF8.91
12.05.06WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.05
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
12.05.07WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP
12.05.08WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
12.05.09WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
12.06ROOF CONFIGURATION

1 Ply Mineral Surfaced Cap Sheet Adhered in Hot ASTM D 312 Type III or IV Asphalt

12.06.01ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensileSF6.23
12.06.02ROOFING MEMBRANE OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensileSF8.36
12.06.03ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensileSF7.51
12.06.04ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensileSF9.73
12.06.05ROOFING MEMBRANE OPTION:ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensileSF10.78
12.06.06WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.06
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
12.06.07WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-3
12.06.08WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1
12.06.09WARRANTY UPCHARGE:Add to provide coverage for roof uplift pressures up to 120 MPHSFNSP-2
12.07ROOF CONFIGURATION

1 Ply Cap Sheet, Set in Hot ASTM D 312 Type III or IV Asphalt, Flood Coat & Aggregate in Hot Modified Coal Tar Pitch

12.07.01ROOFING MEMBRANE & COATING OPTION:ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF10.32
12.07.02ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF12.14
12.07.03ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF12.04
12.07.04ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF13.56
12.07.05ROOFING MEMBRANE & COATING OPTIONASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum 600 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% ElongationSF14.19
12.07.06COATING OPTION:Add/Deduct for Installing Flood Coat in Cold Process Coal Tar PitchSF-0.95
12.07.07WARRANTY CHARGE:Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.07
Must includes coverage for roof uplift pressures up to 90 MPHSFNSP
12.07.08WARRANTY UPCHARGE:Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar LimitationsSFNSP
12.07.09WARRANTY UPCHARGE:Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar LimitationsSFNSP-1