This document represents a comprehensive state and local contract indefinite delivery vehicle (IDV) for roofing services and materials, specifically Contract 190-25, awarded to Garland/DBS Inc. The contract appears to be a statewide roofing contract that provides detailed pricing and service options for various roofing systems, repairs, installations, and related professional services.
The contract encompasses an extensive range of roofing solutions, including built-up modified roof systems, single-ply roof systems, metal roofing, wall coatings, flashings, and restoration services. Pricing is provided on a per-square-foot basis for numerous configurations, such as different deck types (metal, wood, concrete), insulation options, membrane materials, and installation methods. The contract includes detailed pricing for tear-off and disposal, deck replacement, insulation recovery, professional services, and specialized restoration techniques. Notable features include options for different warranty periods (15-30 years), wind uplift coverage, and multiple material choices like EPDM, TPO, PVC, and KEE membranes. The contract also provides unit pricing for ancillary services like caulking, masonry repairs, drainage solutions, and job-specific multipliers that adjust costs based on project complexity, access, and size.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 190-25_Bid_Document.pdf | ||
| Affirmation_and_Disclosure_Signed__1_.pdf | ||
| Line_Item_Pricing_-Garland_DBS_190-25__1_.xlsx | XLSX spreadsheet | |
| Signature.pdf | ||
| Garland_DBS_Material_Price_File_190-25.xlsx | XLSX spreadsheet | |
| ODOT_Co-Op_Program_Information.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Manufacturers Contacts
| 190-25 STATEWIDE ROOFING CONTRACT | ||||
| Manufacturers Contacts | ||||
| Vendor Name: | Garland/DBS Inc. | |||
| Position/Function | Name | Email Address | Telephone Number | Alternate/Other Telephone Number |
| Director of Strategic Operations | Jordan Trimble | jtrimble@garlandco.com | 216-430-3534 | |
| Contract Administrator | Steve Rojek | srojek@garlandco.com | 216-430-3634 | |
| Contract Administrator | Stephen Rosenthal | srosenthal@garlandco.com | 216-430-3552 |
Administrative Fee
| 190-25 STATEWIDE ROOFING CONTRACT | ||||
| Vendor Name: | Garland/DBS Inc. | |||
| Manufacturer specified percentage (%) administrative fee for management of identified projects. | ITEM 1 | Administrative Fee | 0.00% |
Systems
| 190-25 Roofing | |||||
| Line Item | Unit | $ per Unit | |||
| 1.00 | Roof Management, Design Assistant and/or Professional Services | ||||
| 1.01 | Full-time Quality Assurance monitoring | DAY | 882.00 | ||
| 1.02 | Asbestos core testing and analysis (testing only, excludes labor for sampling and repair) | EA | 110.25 | ||
| 1.03 | Analysis and evaluation (14” x 14” roof core) (Lab testing only, repairs charged at roof repair rates for appropriate system type) | EA | NSP | ||
| 1.04 | Aerial Roof Survey - Roof Pictures & Drawings Including Geometries, Slope, Calculated Area and Perimeter Measurements | EA | NSP | ||
| 1.05 | Aerial Wall Survey - Wall Pictures & Drawings Including Geometries, Calculated Area and Perimeter Measurements | EA | NSP | ||
| 1.06 | Manufacturer Standing Seam Material Quantity Estimating | EA | NSP | ||
| 1.07 | Nuclear Moisture Survey, Non destructive roof scan | ||||
| 1.07.01 | Non destructive roof scan, up to 20 000 SF | EA | 3,150.00 | ||
| 1.07.02 | Non destructive roof scan, over 20,000 SF | SF | 0.14 | ||
| 1.08 | Infrared Moisture Scanning | ||||
| 1.08.01 | Non destructive infrared roof scan, up to 20 000 SF | EA | 2,047.50 | ||
| 1.08.02 | Non destructive infrared roof scan, over 20,000 SF | SF | 0.09 | ||
| 1.08.03 | Aerial infrared roof scan at night | TRIP | 2,388.75 | ||
| 1.09 | Infrared scanning equipment rental | DAY | NSP | ||
| 1.10 | Roof investigation (visual roof survey) | ||||
| 1.10.01 | Roof Investigation (Roof by Roof), per hour | HOUR | NSP | ||
| 1.10.02 | Visual Roof Survey (Roof by Roof) up to 20,000 SF | EA | NSP | ||
| 1.10.03 | Visual Roof Survey (Roof by Roof) over 20,000 SF | SF | NSP | ||
| 1.10.04 | Visual Roof Survey (Single Campus - All Roof Sections) | SF | 0.08 | ||
| 1.10.05 | Visual Roof Survey (Multiple Campuses City-/County-wide - All Roof Sections) | SF | 0.14 | ||
| 1.10.06 | Visual Roof Survey (Multiple Campuses State-wide - All Roof Sections) | SF | 0.14 | ||
| 1.10.07 | Roof core cut (roof by roof) | EA | NSP | ||
| 1.10.08 | Roof core cut per roof section (all roof sections on campus(s)) | EA | 204.75 | ||
| 1.11 | Comprehensive reporting | ||||
| 1.11.01 | Comprehensive report for visual survey (Roof by Roof) | EA | NSP | ||
| 1.11.02 | Comprehensive report for visual survey(All Roof Sections on Campus(es) | EA | 136.50 | ||
| 1.11.03 | Comprehensive report for each roof section(s) surveyed (Item 1.07) or scanned (Item 1.08) | EA | 341.25 | ||
| 1.11.04 | Comprehensive report enertered into on-line data base for dynamic reporting and tracking all roofing sections on Campus(s) | EA | NSP | ||
| 1.12 | Manufacturer's Technical Representative Contractor Training Session at Job Start-Up | DAILY | NSP | ||
| 1.13 | Wind Uplift Testing – Mobilize and provide wind uplift testing per Factory Mutual System Roof Design Manual FM 1-52 | EA | NSP | ||
| 1.14 | Roof drawings to scale with all rooftop equipment and penetrations | ||||
| 1.14.01 | Roof drawings (Roof by Roof) | EA | NSP | ||
| 1.14.02 | Roof drawings (All Roof Sections on Campus(es) | EA | 118.13 | ||
| 1.15 | Project Building Code Review | EA | NSP | ||
| 1.16 | Additional and Occasional Services | ||||
| 1.16.01 | Project Architect for Design Professional Services | HOUR | 170.63 | ||
| 1.16.02 | Principle Architect for Design Professional Services | HOUR | 238.88 | ||
| 1.16.03 | Project Engineer for Engineering Reviews | HOUR | 170.63 | ||
| 1.16.04 | Principle Architect for Engineering Reviews | HOUR | 238.88 | ||
| 1.16.06 | Roof Consultant | HOUR | 170.63 | ||
| 1.16.07 | Full-Time Job Site Superintendent | DAY | 819.00 | ||
| 1.16.08 | CAD Draftsman | HOUR | 102.38 | ||
| 1.17 | Laboratory Analysis | ||||
| 1.17.01 | Laboratory Fungal Analysis: Cultured Fungi Identification & Enumeration (Not including engineering time for sampling) | EA | 443.63 | ||
| 1.17.02 | Laboratory Fungal Analysis: Total Fungi Spore Count (Not including engineering time for sampling) | EA | 443.63 | ||
| 1.17.03 | Laboratory Mold Analysis: Viable Airborne Mold Analysis (Not including engineering time for sampling) | EA | 443.63 | ||
| 1.17.04 | Laboratory Analysis: Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling) | EA | 443.63 | ||
| 1.17.05 | Laboratory Analysis: Non-Viable Surface Swab or Bulk Substrate Analysis (Not including engineering time for sampling) | EA | 443.63 | ||
| 1.17.06 | Destructive Roof Sample Analysis: | ||||
| Comprehensive laboratory testing of a core sample from an existing roof to include tensile/tear strength, scrim type, interply bitumen weight and roof composition; Repair the roof core area with similar materials. | EA | NSP | |||
| 1.18 | Travel Expenses | ||||
| 1.18.01 | Per Diem – Meals and Incidentals | DAY | NSP | ||
| 1.18.02 | Lodging | DAY | NSP | ||
| 1.18.03 | Mileage on Company / Personal Vehicle | MILE | NSP | ||
| 1.18.04 | Airfare (Economy) | JOB | NSP | ||
| 1.18.05 | Vehicle Rental | DAY | NSP | ||
| 1.19 | Seamer Rental Charges | DAY | NSP | ||
| 1.20 | Set-up Charges for Metal In-Shop Fabrication | EA | NSP | ||
| 1.21 | Set-up On-Site Roll Forming | EA | NSP | ||
| 1.22 | Roof Fastener Pull Tests (As Many as Required per Roof Section) | EA | NSP | ||
| 1.23 | Wind Uplift Design Calculations | EA | NSP | ||
| 1.24 | Roof Drainage Capacity Calculations | EA | NSP | ||
| 1.25 | Roof Edge Metal Calculations - ANSI/SPRI ES-1 Standards | EA | NSP | ||
| 1.26 | Dew Point Calculations | EA | NSP | ||
| 1.27 | Energy Payback Calculations | EA | NSP | ||
| 1.28 | Project Life-Cycle Cost Calculation | EA | NSP | ||
| 1.29 | Substantial Completion Walkthrough with Report and Punchlist | EA | NSP | ||
| 1.30 | Final Walkthrough with Report | EA | NSP | ||
| 1.31 | On-Site Quality Control Inspections with Report from Manufacturer's Rep - 3 Days per Week | WEEK | NSP | ||
| 1.32 | "As-Built" Drawings Upon Project Completion | EA | NSP | ||
| 1.33 | R.A. or P.E. Reviewed and Stamped Shop Drawings | EA | NSP | ||
| 1.34 | R.A. or P.E. Reviewed and Stamped Specifications | EA | NSP | ||
| 1.35 | Non-R.A./P.E. Reviewed Shop Drawings | EA | NSP | ||
| 1.36 | Project Design Assistance - Hourly Rate for Consultations with Architect of Record | EA | NSP | ||
| 1.37 | Project Design Assistance - Development of a recommended specification for a roofing or waterproofing project | EA | NSP | ||
| 1.38 | Roof Asset Management Report with recommended options for future course of actions and associated budgets for capital expense and maintenance planning. | EA | NSP | ||
| 1.39 | Five year capital expense and maintenance plan ( All roof section on for campus(es)) | EA | NSP | ||
| 1.40 | Additional Professional Services | ||||
| 1.40.01 | Option 1: Professional Services (Third party architectural design, engineering or consulting services quote on corporate letterhead) | ||||
| Cost plus added to quote | % | 14% | |||
| 1.40.02 | Option 2: R.S. Means or Gordian Group Catalog (Used when professional services line item pricing is not available) | ||||
| Cost plus added to catalog pricing | % | 14% | |||
| 2.00 | Tear-off & Dispose of Debris | ||||
| 2.01 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Gravel Surfacing - Metal Deck | SF | 3.96 | |||
| 2.02 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Gravel Surfacing - Wood / Tectum Deck | SF | 3.96 | |||
| 2.03 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp Deck | SF | 3.96 | |||
| 2.04 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Gravel Surfacing - Concrete Deck | SF | 3.96 | |||
| 2.05 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Mineral Surfacing - Metal Deck | SF | 3.70 | |||
| 2.06 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Mineral Surfacing - Wood / Tectum Deck | SF | 3.70 | |||
| 2.07 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp Deck | SF | 3.70 | |||
| 2.08 | SYSTEM TYPE | ||||
| BUR W/ Insulation and Mineral Surfacing - Concrete Deck | SF | 3.70 | |||
| 2.09 | SYSTEM TYPE | ||||
| Single-Ply W/ Insulation - Metal Deck | SF | 2.99 | |||
| 2.10 | SYSTEM TYPE | ||||
| Single-Ply W/ Insulation - Wood / Tectum Deck | SF | 2.99 | |||
| 2.11 | SYSTEM TYPE | ||||
| Single-Ply W/ Insulation - Lightweight / Gyp Deck | SF | 2.99 | |||
| 2.12 | SYSTEM TYPE | ||||
| Single-Ply W/ Insulation - Concrete Deck | SF | 2.99 | |||
| 2.13 | SYSTEM TYPE | ||||
| Ballasted Single-Ply W/ Insulation - Metal Deck | SF | 4.29 | |||
| 2.14 | SYSTEM TYPE | ||||
| Ballasted Single-Ply W/ Insulation - Wood / Tectum Deck | SF | 4.29 | |||
| 2.15 | SYSTEM TYPE | ||||
| Ballasted Single-Ply W/ Insulation - Lightweight / Gyp Deck | SF | 4.29 | |||
| 2.16 | SYSTEM TYPE | ||||
| Ballasted Single-Ply W/ Insulation - Concrete Deck | SF | 4.29 | |||
| 2.17 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Gravel Surfacing - Metal Deck | SF | 4.43 | |||
| 2.18 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Gravel Surfacing - Wood / Tectum Deck | SF | 4.43 | |||
| 2.19 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Gravel Surfacing - Lightweight / Gyp Deck | SF | 4.43 | |||
| 2.20 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Gravel Surfacing - Concrete Deck | SF | 4.43 | |||
| 2.21 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Mineral Surfacing - Metal Deck | SF | 4.17 | |||
| 2.22 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Mineral Surfacing - Wood / Tectum Deck | SF | 4.17 | |||
| 2.23 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Mineral Surfacing - Lightweight / Gyp Deck | SF | 4.17 | |||
| 2.24 | SYSTEM TYPE | ||||
| Coal Tar BUR W/ Insulation and Mineral Surfacing - Concrete Deck | SF | 4.17 | |||
| 2.25 | SYSTEM TYPE | ||||
| Metal Roofing or Metal Wall Panel System - Metal Deck | SF | 4.00 | |||
| 2.26 | SYSTEM TYPE | ||||
| Metal Roofing or Metal Wall Panel System - Metal Deck - Wood / Tectum Deck | SF | 4.00 | |||
| 2.27 | SYSTEM TYPE | ||||
| Metal Roofing or Metal Wall Panel System - Metal Deck - Lightweight / Gypsum Deck | SF | 4.00 | |||
| 2.28 | SYSTEM TYPE | ||||
| Metal Roofing or Metal Wall Panel System - Metal Deck - Concrete Deck | SF | 4.00 | |||
| 2.29 | SYSTEM TYPE | ||||
| Dimensional/Architectural Shingle Roof - Wood Deck | SF | 1.62 | |||
| 2.30 | SYSTEM TYPE | ||||
| 3-Tab Shingle Roof - Wood Deck | SF | 1.62 | |||
| 2.31 | SYSTEM TYPE | ||||
| Clay Tile Shingle Roof - Wood Deck | SF | 4.32 | |||
| 2.32 | SYSTEM TYPE | ||||
| Concrete Tile Shingle Roof - Wood Deck | SF | 4.32 | |||
| 2.33 | SYSTEM TYPE | ||||
| Slate Tile Shingle Roof - Wood Deck | SF | 4.90 | |||
| 2.34 | SYSTEM TYPE | ||||
| Cedar / Wood Shake Shingle Roof - Wood Deck | SF | 4.32 | |||
| 2.35 | SYSTEM TYPE | ||||
| Add to save good Clay Tile Shingles for reuse | SF | 1.26 | |||
| 2.36 | SYSTEM TYPE | ||||
| Add to save good Concrete Tile Shingles for reuse | SF | 1.26 | |||
| 2.37 | SYSTEM TYPE | ||||
| Add to save good Slate Tile Shingles for reuse | SF | 1.26 | |||
| 2.38 | SYSTEM TYPE | ||||
| Add to save good Cedar / Wood Shake Shingles for reuse | SF | 2.59 | |||
| 2.39 | SYSTEM TYPE | ||||
| Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Metal Deck | SF | 4.20 | |||
| 2.40 | SYSTEM TYPE | ||||
| Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Wood / Tectum Deck | SF | 4.20 | |||
| 2.41 | SYSTEM TYPE | ||||
| Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Lightweight / Gyp Deck | SF | 4.20 | |||
| 2.42 | SYSTEM TYPE | ||||
| Polyurethane Foam (PUF) Roof (Average of 2" thick) W/ Underlying Insulation and UV-Resistant Coating - Concrete Deck | SF | 4.20 | |||
| 2.43 | SYSTEM TYPE | ||||
| Add of Each Additional Average Depth 1" of Polyurethane Foam (PUF) Roofing | SF | 1.60 | |||
| 2.44 | SYSTEM TYPE | ||||
| BUR w/ Gravel Surfacing to the Existing Insulation (Insulation to be Re-Used) | SF | 4.00 | |||
| 2.45 | SYSTEM TYPE | ||||
| BUR w/ Mineral Surfacing to the Existing Insulation (Insulation to be Re-Used) | SF | 3.96 | |||
| 2.46 | SYSTEM TYPE | ||||
| Single-Ply to the Existing Insulation (Insulation to be Re-Used | SF | 3.21 | |||
| 2.47 | SYSTEM TYPE | ||||
| Ballasted Single-Ply to the Existing Insulation (Insulation to be Re-Used | SF | 2.50 | |||
| 2.48 | SYSTEM TYPE | ||||
| Coal Tar BUR with Gravel Surfacing to the Existing Insulation (Insulation to be Re-Used) | SF | 4.64 | |||
| 2.49 | SYSTEM TYPE | ||||
| Coal Tar BUR with Mineral Surfacing to the Existing Insulation (Insulation to be Re-Used) | SF | 4.64 | |||
| 2.99 | MULTIPLIER - TEAR-OFF & DISPOSE OF DEBRIS | ||||
| Each Additional Roof System | % | 44% | |||
| 3.00 | Removal & Replacement of Roof Deck | ||||
| 3.01 | DECK TYPE | ||||
| Spot Metal Deck Replacement (Multiple areas under 1 square) | SF | 23.16 | |||
| 3.02 | DECK TYPE | ||||
| Spot Wood Deck Replacement (Multiple areas under 1 square) | SF | 21.19 | |||
| 3.03 | DECK TYPE | ||||
| Spot Gypsum Deck Replacement (Multiple areas under 1 square) | SF | 67.57 | |||
| 3.04 | DECK TYPE | ||||
| Spot Concrete Deck Replacement (Multiple areas under 1 square) | SF | 51.79 | |||
| 3.05 | DECK TYPE | ||||
| Spot Lightweight Deck Replacement (Multiple areas under 1 square) | SF | 30.01 | |||
| 3.06 | DECK TYPE | ||||
| Spot Tectum Deck Replacement (Multiple areas under 1 square) | SF | 28.75 | |||
| 3.07 | DECK TYPE | ||||
| Large Areas of Metal Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 14.39 | |||
| 3.08 | DECK TYPE | ||||
| Large Areas of Wood Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 15.25 | |||
| 3.09 | DECK TYPE | ||||
| Large Areas of Gypsum Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 55.39 | |||
| 3.10 | DECK TYPE | ||||
| Large Areas of Concrete Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 42.44 | |||
| 3.11 | DECK TYPE | ||||
| Large Areas of Lightweight Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 22.56 | |||
| 3.12 | DECK TYPE | ||||
| Large Areas of Tectum Deck Replacement (Replacement areas averaging greater than 1 square) | SF | 23.00 | |||
| 4.00 | Insulation Recovery Board & Insulations Options | ||||
| 4.01 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; Mopped | SF | 1.52 | |||
| 4.02 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Adhered with Insulation Adhesive | SF | 2.91 | |||
| 4.03 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Metal Deck | SF | 1.54 | |||
| 4.04 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Wood / Tectum Deck | SF | 1.66 | |||
| 4.05 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Lightweight / Gypsum Deck | SF | 1.70 | |||
| 4.06 | RECOVERY BOARD TYPE | ||||
| 1/2" Wood Fiber or Perlite Board Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Concrete Deck | SF | 1.74 | |||
| 4.07 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Adhered in Hot ASTM D 312 Type III or IV Asphalt; Mopped | SF | 2.65 | |||
| 4.08 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Adhered with Insulation Adhesive | SF | 3.89 | |||
| 4.09 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Metal Deck | SF | 2.69 | |||
| 4.10 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Wood / Tectum Deck | SF | 2.93 | |||
| 4.11 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Lightweight / Gypsum Deck | SF | 2.99 | |||
| 4.12 | RECOVERY BOARD TYPE | ||||
| 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) Installed Over an Existing Roof Mechanically Fastened to Roof Deck - Concrete Deck | SF | 3.09 | |||
| 4.13 | ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) | ||||
| Install 1.0" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of Insulation | SF | 2.74 | |||
| 4.14 | ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) | ||||
| Install 1.5" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of Insulation | SF | 2.95 | |||
| 4.15 | ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) | ||||
| Install 2.0" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of Insulation | SF | 3.45 | |||
| 4.16 | ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) | ||||
| Install 2.5" of Polyisocyanurate Insulation Over an Existing Roof. All Wet Insulation Must be Replaced Prior to Installation of New Course of Insulation | SF | 3.97 | |||
| 4.17 | ADDITIONAL INSULATION OPTION (OVER AN EXISTING ROOF) | ||||
| Add for Cutting New Insulation to Match the Profile of an Existing Metal Roof. | SF | 1.97 | |||
| 4.18 | INSULATION SUBSTITUTION OPTION | ||||
| Deduct for Providing an R-Value of greater than or equal to 10, but less than 15; instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems | SF | -0.83 | |||
| 4.19 | INSULATION SUBSTITUTION OPTION | ||||
| Deduct for Providing an R-Value of greater than or equal to 15, but less than 18; instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems | SF | -0.49 | |||
| 4.20 | INSULATION SUBSTITUTION OPTION: | ||||
| Deduct for Providing an R-Value of greater than or equal to 18, but less than 20 instead of the Standard R-Value of 20 (Should be Negatively Priced) - All Applications Other Than Metal Roof Systems | SF | -0.23 | |||
| 4.21 | INSULATION SUBSTITUTION OPTION: | ||||
| Add for Providing an R-Value of 25 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof Systems | SF | 0.89 | |||
| 4.22 | INSULATION SUBSTITUTION OPTION: | ||||
| Add for Providing an R-Value of 30 Instead of the Standard R-Value of 20 - All Applications Other Than Metal Roof Systems | SF | 1.81 | |||
| 4.23 | INSULATION SUBSTITUTION OPTION | ||||
| Substitute 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Place of the Wood Fiber or Perlite - Adhered in Hot ASTM D 312 Type III or IV Asphalt; Mopped | SF | 1.11 | |||
| 4.24 | INSULATION SUBSTITUTION OPTION | ||||
| Substitute 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Place of the Wood Fiber or Perlite - Adhered with Insulation Adhesive | SF | 1.11 | |||
| 4.25 | INSULATION SLOPE OPTION | ||||
| Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered Crickets; Adhered in ASTM D 312 Type III or IV Hot Asphalt; Mopped | SF | 10.11 | |||
| 4.26 | INSULATION SLOPE OPTION | ||||
| Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered in ASTM D 312 Type III or IV Hot Asphalt; Mopped | SF | 7.22 | |||
| 4.27 | INSULATION SLOPE OPTION | ||||
| Provide a 1/4" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value Including Tapered Crickets; Adhered with Insulation Adhesive | SF | 16.38 | |||
| 4.28 | INSULATION SLOPE OPTION | ||||
| Provide a 1/8" Tapered Polyisocyanurate Insulation System while Maintaining the Average R-Value; Adhered with Insulation Adhesive | SF | 11.51 | |||
| 4.29 | INSULATION SUBSTITUTION OPTION | ||||
| Provide a 1/4" Tapered Insulating Lightweight Concrete System while Maintaining Average R-Value | SF | 12.58 | |||
| 4.30 | INSULATION SUBSTITUTION OPTION | ||||
| Provide a 1/8" Tapered Insulating Lightweight Concrete System while Maintaining Average R-Value | SF | 11.67 | |||
| 4.31 | INSULATION ATTACHMENT OPTION: | ||||
| Provide Attachment Pattern in Compliance with FM 1-60 Wind Uplift Instead of FM 1-90 | SF | -0.04 | |||
| 4.32 | INSULATION ATTACHMENT OPTION: | ||||
| Provide Attachment Pattern in Compliance with FM 1-120 Wind Uplift Instead of FM 1-90 | SF | 0.24 | |||
| 5.00 | Coat New Roofing With Elastomeric Coating | ||||
| 5.01 | ROOF SYSTEM TYPE | ||||
| Apply an Acrylic Coating per Specifications (1.5 Gallons per Square per Coat - 2 Coats Required) - Mineral-Surfaced Modified Roof | SF | 6.04 | |||
| 5.02 | ROOF SYSTEM TYPE | ||||
| Apply an Acrylic Coating per Specifications (1.0 Gallon per Square per Coat - 2 Coats Required) - Smooth-Surfaced Modified Roof | SF | 4.69 | |||
| 5.03 | ROOF SYSTEM TYPE | ||||
| Apply a bright white, water-based, acrylic-urethane hybrid roof coating per Specifications (1.5 Gallons per Square per Coat - 2 Coats Required) - Mineral-Surfaced Modified Roof | SF | 8.04 | |||
| 5.04 | ROOF SYSTEM TYPE | ||||
| Apply a bright white, water-based, acrylic-urethane hybrid roof coating per Specifications (1.0 Gallon per Square per Coat - 2 Coats Required) - Smooth-Surfaced Modified Roof | SF | 5.97 | |||
| 5.05 | ROOF SYSTEM TYPE | ||||
| Apply an Acrylic base coat and a PVDF top coat per Specifications (1.5 Gallons per Square Base Coat - 1/2 Gallon per Square Top Coat) - Mineral-Surfaced Modified Roof | SF | 7.47 | |||
| 5.06 | ROOF SYSTEM TYPE | ||||
| Apply an Acrylic base coat and a PVDF top coat per Specifications (1 Gallon per Square Base Coat - 1/2 Gallon per Square Top Coat) -Smooth-Surfaced Modified Roof | SF | 6.55 | |||
| 5.07 | ROOF SYSTEM TYPE | ||||
| Apply an Urethane Coating per Specifications (1 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral Surfaced Modified; With Reinforced Seams (Base Coat Seam with 1.5 Gallons per Square & Reinforcement) | SF | 13.94 | |||
| 5.08 | ROOF SYSTEM TYPE | ||||
| Apply a single-component, aliphatic, polyurea liquid adhesive per Specifications (Apply 1.0 gallon per Square on Seams & wait 24 Hours / Apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 200 lbs. per Square / wait 24 hours and apply top coat at 1.0 gallon per Square - Mineral-Surfaced Modified | SF | 12.02 | |||
| 5.09 | ROOF SYSTEM TYPE | ||||
| Apply a single-component, aliphatic, polyurea liquid adhesive per Specifications (apply base coat at 1.0 gallon per Square / broadcast mineral at 35 lbs. per Square or white gravel at 200 lbs. per Square / wait 24 hours and apply top coat at 1.0 gallon per Square - Smooth-Surfaced Modified | SF | 12.02 | |||
| 5.10 | ROOF SYSTEM TYPE | ||||
| Apply an Aluminum Coating per Specifications (3/4 Gallon per Square per Coat - 2 Coats Required) - Smooth or Mineral Surfaced Modified | SF | 3.27 | |||
| 5.11 | ROOF SYSTEM TYPE | ||||
| Apply a Fibered Aluminum Coating per Specifications (2 Gallons per Square per Coat - 1 Coat Required) - Smooth or Mineral Surfaced Modified | SF | 3.97 | |||
| 6.00 | Roof Deck and Insulation Option | ||||
| 6.01 | METAL ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 6.01.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 | |||
| In Compliance with FM 1-90 Requirements | SF | 5.62 | |||
| 6.02 | WOOD ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 6.02.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 | SF | 5.30 | |
| 6.02.02 | INSULATION OPTION: | Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base Sheet | SF | 1.75 | |
| 6.03 | TECTUM ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 6.03.01 | INSULATION OPTION: | Mechanically Attach Base Sheet Utilizing FM 1-90 Attachment Patterns & Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 | SF | 9.19 | |
| 6.03.02 | INSULATION OPTION: | Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base Sheet | SF | 2.54 | |
| 6.04 | LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 6.04.01 | INSULATION OPTION: | Must Mechanically Attach a Base Sheet; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 9.19 | INSULATION OPTION: Must Mechanically Attach a Base Sheet; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 |
In Compliance FM 1-90 Requirements
| 6.04.02 | INSULATION OPTION: | Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation | |||
| Installed with FM 1-90 Attachment Patterns | SF | 2.54 | |||
| 6.05 | CONCRETE ROOF DECK - HOT APPLICATION - ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 6.05.01 | INSULATION OPTION: | Prime Roof Deck; Hot Mop Polyisocyanurate / Hot Mop Wood Fiber or Perlite to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 6.15 | |||
| 6.05.02 | INSULATION OPTION: | Without Insulation - Prime Roof Deck; Must at Least 1/2" Wood Fiber or Perlite Hot Mopped to Deck | |||
| In Compliance FM 1-90 Requirements | SF | 1.52 | |||
| 6.06 | METAL ROOF DECK - COLD PROCESS APPLICATION | ||||
| 6.06.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 6.27 | |||
| 6.07 | WOOD ROOF DECK - COLD PROCESS APPLICATION | ||||
| 6.07.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 | SF | 6.27 | |
| 6.07.02 | INSULATION OPTION: | Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base Sheet | SF | 1.75 | |
| 6.08 | TECTUM ROOF DECK - COLD PROCESS APPLICATION | ||||
| 6.08.01 | INSULATION OPTION: | Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 | SF | 12.54 | |
| 6.08.02 | INSULATION OPTION: | Without Insulation - Must Include Rosin & Mechanically Fasten Glass Base Sheet | SF | 2.56 | |
| 6.09 | LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - COLD PROCESS APPLICATION | ||||
| 6.09.01 | INSULATION OPTION: | Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 12.54 | |||
| 6.09.02 | INSULATION OPTION: | Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck | |||
| Installed with FM 1-90 Attachment Patterns | SF | 2.56 | |||
| 6.10 | CONCRETE ROOF DECK - COLD PROCESS APPLICATION | ||||
| 6.10.01 | INSULATION OPTION: | Adhere Polyisocyanurate in Insulation Adhesive / Adhere High Density Asphalt Coated Wood Fiber with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 9.27 | |||
| 6.10.02 | INSULATION OPTION: | Without Insulation - Must at Least 1/2" High Density Asphalt Coated Wood Fiber Adhered with Insulation Adhesive to Deck | |||
| In Compliance FM 1-90 Requirements | SF | 2.23 | |||
| 6.11 | METAL ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION | ||||
| 6.11.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 7.08 | |||
| 6.12 | WOOD ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION | ||||
| 6.12.01 | INSULATION OPTION: | Mechanically Fasten Polyisocyanurate / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 | SF | 7.08 | |
| 6.12.02 | INSULATION OPTION: | Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) | SF | 1.76 | |
| 6.13 | TECTUM ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION | ||||
| 6.13.01 | INSULATION OPTION: | Mechanically Attach Base Sheet & Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 | SF | 13.15 | |
| 6.13.02 | INSULATION OPTION: | Without Insulation - Must Mechanically Attach 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) | SF | 2.60 | |
| 6.14 | LIGHTWEIGHT CONCRETE / GYPSUM ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION | ||||
| 6.14.01 | INSULATION OPTION: | Must Mechanically Attach a Base Sheet; Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 13.15 | |||
| 6.14.02 | INSULATION OPTION: | Without Insulation - Must at Least Mechanically Fasten a Base Sheet to the Roof Deck Prior to Installation | |||
| Installed with FM 1-90 Attachment Patterns | SF | 2.60 | |||
| 6.15 | CONCRETE ROOF DECK - TORCH APPLIED / SELF-ADHERING APPLICATION | ||||
| 6.15.01 | INSULATION OPTION: | Adhere Polyisocyanurate in Insulation Adhesive / Adhere Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) with Insulation Adhesive to Provide an Average R-Value of 20 | |||
| In Compliance FM 1-90 Requirements | SF | 9.85 | |||
| 6.15.02 | INSULATION OPTION: | Without Insulation - Must Adhere 1/2" Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal) in Insulation Adhesive | |||
| In Compliance FM 1-90 Requirements | SF | 2.95 | |||
| 6.16 | INSTALL PRIOR TO ROOF SYSTEM INSULATION: | ||||
| 6.16.01 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK: |
Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal), Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt
| In Compliance with FM 1-90 Requirements | SF | 3.99 | |
| 6.16.02 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt | |
| In Compliance with FM 1-90 Requirements | SF | 4.13 | |
| 6.16.03 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK: | |
| Prime Deck Prior to Applying 2 Plies of Glass Felt in Hot ASTM D 312 Type III OR IV Asphalt | SF | 2.75 | |
| 6.16.04 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK: |
Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); Apply 2 Plies of Glass Base in Cold Process Modified Asphalt
| In Compliance with FM 1-90 Requirements | SF | 6.30 | |
| 6.16.05 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Apply 2 Plies of Glass Base in Cold Process Modified Asphalt | |
| In Compliance with FM 1-90 Requirements | SF | 6.30 | |
| 6.16.06 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK: | |
| Prime Deck Prior to Applying 2 Plies of Glass Base in Cold Process Modified Asphalt | SF | 4.89 | |
| 6.16.07 | VAPOR BARRIER OPTION: | TORCH-APPLIED VAPOR BARRIER ON METAL DECK: |
Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); Heat Weld with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147)
| In Compliance with FM 1-90 Requirements | SF | 6.92 | |
| 6.16.08 | VAPOR BARRIER OPTION: | TORCH-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, Heat Weld with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147) | |
| In Compliance with FM 1-90 Requirements | SF | 7.14 | |
| 6.16.09 | VAPOR BARRIER OPTION: | TORCH-APPLIED VAPOR BARRIER ON CONCRETE DECK: | |
| Prime Deck Prior to Heat Welding with Torch 1 Ply of SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147) | SF | 5.73 | |
| 6.16.10 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK: |
Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal), ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt
| In Compliance with FM 1-90 Requirements | SF | 5.30 | |
| 6.16.11 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt | |
| In Compliance with FM 1-90 Requirements | SF | 5.69 | |
| 6.16.12 | VAPOR BARRIER OPTION: | HOT ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK: | |
| Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Hot ASTM D 312 Type III OR IV Asphalt | SF | 4.18 | |
| 6.16.13 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON METAL DECK: |
Mechanically-Fasten Treated Gypsum Insulation Board with Glass-Mat (e.g. DensDeck / Securock / Equal); ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified Asphalt
| In Compliance with FM 1-90 Requirements | SF | 6.55 | |
| 6.16.14 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON WOOD, TECTUM, LIGHTWEIHT CONCRETE OR GYPSUM DECK: Mechanically Fasten Glass Base Sheet, ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified Asphalt | |
| In Compliance with FM 1-90 Requirements | SF | 6.51 | |
| 6.16.15 | VAPOR BARRIER OPTION: | COLD ASPHALT-APPLIED VAPOR BARRIER ON CONCRETE DECK: | |
| Prime Deck Prior to ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile in Cold Process Modified Asphalt | SF | 5.11 | |
| 7.00 | BUILT-UP MODIFIED ROOF WITH FLOOD COAT AND AGGREGATE IN HOT ASTM D 312 TYPE III OR IV ASPHALT | ||
| 7.01 | ROOF CONFIGURATION |
2 Plies of Glass Felt, Cap Sheet, Flood Coat and Aggregate All in Hot ASTM D 312 Type III OR IV Asphalt
| 7.01.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 8.48 | |
| 7.01.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 10.25 | |
| 7.01.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 10.12 | |
| 7.01.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile | SF | 11.67 | |
| 7.01.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensile | SF | 12.31 | |
| 7.02 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 7.00 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 7.03 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP | |
| 7.04 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 7.05 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 7.06 | DEDUCT TO SQUARE FOOT COST - Hot Applied Modified BUR | ||||
| Substitute Additional Glass Felt (Hot Applications) in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile (i.e. 3 Ply BUR) | SF | 3.17 | |||
| 7.07 | ADD TO PER SQUARE FOOT COST - Hot Applied Modified BUR | ||||
| Each Additional Glass Felt (Hot Applications) Inter-ply Installed | SF | 1.13 | |||
| 8.00 | BUILT-UP MODIFIED ROOF WITH FLOOD COAT AND AGGREGATE IN COLD PROCESS ASPHALT | ||||
| 8.01 | ROOF CONFIGURATION |
2 Plies of Glass Base, Cap Sheet, Flood Coat and Aggregate All in Cold Process Modified Asphalt
| 8.01.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 14.00 | |
| 8.01.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 15.95 | |
| 8.01.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 15.84 | |
| 8.01.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile | SF | 17.38 | |
| 8.01.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensile | SF | 18.00 | |
| 8.02 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 8.00 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 8.03 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP | |
| 8.04 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 8.05 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 8.06 | DEDUCT TO SQUARE FOOT COST - Cold Applied Modified BUR | ||||
| Substitute Additional Glass Base Sheet in Place of ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile (i.e. 3 Ply BUR) | SF | -1.74 | |||
| 8.07 | ADD TO PER SQUARE FOOT COST - Cold Applied Modified BUR | ||||
| Each Additional Glass Base (Cold Applications) Inter-ply Installed | SF | 2.60 | |||
| 9.00 | BUILT-UP MODIFIED ROOF ADHERED IN HOT ASTM D 312 TYPE III OR IV ASPHALT - FLOOD COAT & AGGREGATE IN MODIFIED COAL TAR PITCH | ||||
| 9.01 | ROOF CONFIGURATION |
2 ply of Glass Felt, Cap Sheet, Set in Hot Asphalt, Flood Coat in Modified Coal Tar Pitch and Aggregate
| 9.01.01 | ROOFING MEMBRANE & COATING OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 12.38 | |
| 9.01.02 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 14.14 | |
| 9.01.03 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 14.04 | |
| 9.01.04 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 15.56 | |
| 9.01.05 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 600 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 16.20 | |
| 9.02 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 9.00 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 9.03 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP | |
| 9.04 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 9.05 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 9.06 | COATING OPTION: | Add/Deduct for Installing Flood Coat in Cold Process Coal Tar Pitch | SF | -0.64 | |
| 10.00 | BUILT-UP MODIFIED ROOF WITH MINERAL CAP SHEET ADHERED IN HOT ASTM D 312 TYPE III OR IV ASPHALT | ||||
| 10.01 | ROOF CONFIGURATION |
2 ply of Glass Felt, Mineral Surfaced Cap Sheet, Set in Hot ASTM D 312 Type III or IV Asphalt
| 10.01.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 7.02 | |
| 10.01.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 9.20 | |
| 10.01.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 8.37 | |
| 10.01.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile | SF | 10.59 | |
| 10.01.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensile | SF | 11.61 | |
| 10.02 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 10.00 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 10.03 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-3 | |
| 10.04 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 10.05 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 11.00 | BUILT-UP MODIFIED ROOF WITH MINERAL CAP SHEET ADHERED IN COLD PROCESS ASPHALT | ||||
| 11.01 | ROOF CONFIGURATION |
2 ply Glass Base, Mineral Cap Sheet, Set in Cold Process Modified Asphalt
| 11.01.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 10.89 | |
| 11.01.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 13.05 | |
| 11.01.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 12.21 | |
| 11.01.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile | SF | 14.43 | |
| 11.01.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensile | SF | 15.48 | |
| 11.02 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 11.00 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 11.03 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-3 | |
| 11.04 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 11.05 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 12.00 | 2-PLY ROOF SYSTEMS - COMBINATIONS OF A BASE PLY & A CAP SHEET (TOP PLY) |
PLEASE NOTE: BASE PLY & CAP SHEET COMBINATIONS MUST BE APPROVED BY THE MANUFACTURER
12.01 ROOF CONFIGURATION
1 Ply Modified Base Sheet Adhered in Hot ASTM D 312 Type III or IV Asphalt
| 12.01.01 | BASE PLY OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile | SF | 3.90 | |
| 12.01.02 | BASE PLY OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 lbf/in tensile | SF | 4.96 | |
| 12.01.03 | BASE PLY OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 lbf/in tensile | SF | 5.15 | |
| 12.01.04 | ADD/DEDUCT TO PER SQUARE FOOT COST - Hot Applied Modified Multi-ply Systems | ||||
| Each Additional Modified Base Sheet (All Hot Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.01.02 + 12.01.02 + 12.01.04 = Two Plies Installed) | SF | -0.46 | |||
| 12.02 | ROOF CONFIGURATION |
1 Ply Modified Base Sheet Adhered in Cold Process Modified Asphalt
| 12.02.01 | BASE PLY OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - 70 lbf/in tensile | SF | 4.90 | |
| 12.02.02 | BASE PLY OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 220 lbf/in tensile | SF | 5.95 | |
| 12.02.03 | BASE PLY OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - 310 lbf/in tensile | SF | 6.16 | |
| 12.02.04 | ADD/DEDUCT TO PER SQUARE FOOT COST - Cold Applied Modified Multi-ply Systems | ||||
| Each Additional Modified Base Sheet (All Cold Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.02.02 + 12.02.02 + 12.02.04 = Two Plies Installed) | SF | -0.54 | |||
| 12.02.05 | INTERPLY ADHESIVE OPTION: | Add/Deduct for Cold Applied Modified Multi-ply Systems | |||
| Substitute Cold Process Adhesive with Alternative Solvent Free Adhesive | SF | 2.63 | |||
| 12.03 | ROOF CONFIGURATION |
1 Ply of Torch Base Sheet Installed with Torch Application
| 12.03.01 | BASE PLY OPTION: | SBS Modified Asphalt-Based, Fiberglass Reinforced Torch Base Sheet - Minimum of 80 lbf/in tensile Torch-Applied Base Sheet (ASTM D 5147) | SF | 4.35 | |
| 12.03.02 | BASE PLY OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - 210 lbf/in tensile | SF | 5.79 | |
| 12.03.03 | ADD/DEDUCT TO PER SQUARE FOOT COST - Torch-Applied Modified Multi-ply Systems | ||||
| Each Additional Modified Base Sheet (All Torch-Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.03.02 + 12.03.02 + 12.03.03 = Two Plies Installed) | SF | -0.29 | |||
| 12.04 | ROOF CONFIGURATION |
1 Ply of Self-Adhering Base Installed Using Self-Adhering Backing
| 12.04.01 | BASE PLY OPTION: | SBS Modified Asphalt-Based, Polyester OR Fiberglass/Polyester OR Fiberglass Reinforced Self-Adhering Base Sheet - Minimum of 50 lbf/in tensile | SF | 4.44 | |
| 12.04.02 | ADD/DEDUCT TO PER SQUARE FOOT COST - Torch-Applied Modified Multi-ply Systems | ||||
| Each Additional Modified Base Sheet (All Torch-Applied Applications) Installed. To be combined with line items above for a labor cost reduction to installed price of two plies of the same modified base sheet vs. the installation of a single base sheet (i.e. 12.04.01 + 12.04.01 + 12.04.02 = Two Plies Installed) | SF | -0.29 | |||
| 12.05 | ROOF CONFIGURATION |
1 Ply Cap Sheet, Flood Coat and Aggregate Adhered in Hot ASTM D 312 Type III OR IV Asphalt
| 12.05.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 4.90 | |
| 12.05.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 6.85 | |
| 12.05.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 6.74 | |
| 12.05.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III – Minimum of 500 lbf/in tensile | SF | 8.27 | |
| 12.05.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III – Minimum of 600 lbf/in tensile | SF | 8.91 | |
| 12.05.06 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.05 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 12.05.07 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP | |
| 12.05.08 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 12.05.09 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 12.06 | ROOF CONFIGURATION |
1 Ply Mineral Surfaced Cap Sheet Adhered in Hot ASTM D 312 Type III or IV Asphalt
| 12.06.01 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile | SF | 6.23 | |
| 12.06.02 | ROOFING MEMBRANE OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile | SF | 8.36 | |
| 12.06.03 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile | SF | 7.51 | |
| 12.06.04 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile | SF | 9.73 | |
| 12.06.05 | ROOFING MEMBRANE OPTION: | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 600 lbf/in tensile | SF | 10.78 | |
| 12.06.06 | WARRANTY CHARGE: | Cost to Provide 20 Year - Labor & Material Warranty with No Dollar Limitations as a Standard Warranty for All Applications in this Section 12.06 | |||
| Must includes coverage for roof uplift pressures up to 90 MPH | SF | NSP | |||
| 12.06.07 | WARRANTY UPCHARGE: | Add to provide coverage for a 25 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-3 | |
| 12.06.08 | WARRANTY UPCHARGE: | Add to provide coverage for a 30 Year Labor & Material Warranty with No Dollar Limitations | SF | NSP-1 | |
| 12.06.09 | WARRANTY UPCHARGE: | Add to provide coverage for roof uplift pressures up to 120 MPH | SF | NSP-2 | |
| 12.07 | ROOF CONFIGURATION |
1 Ply Cap Sheet, Set in Hot ASTM D 312 Type III or IV Asphalt, Flood Coat & Aggregate in Hot Modified Coal Tar Pitch
| 12.07.01 | ROOFING MEMBRANE & COATING OPTION: | ASTM D 6163 SBS Fiberglass Reinforced Modified Bituminous Sheet Material Type I - Minimum of 70 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 10.32 | |
| 12.07.02 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 220 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 12.14 | |
| 12.07.03 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 310 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 12.04 | |
| 12.07.04 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum of 500 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 13.56 | |
| 12.07.05 | ROOFING MEMBRANE & COATING OPTION | ASTM D 6162 SBS Fiberglass/Polyester Reinforced Modified Bituminous Sheet Material Type III - Minimum 600 lbf/in tensile, Flood Coat in Modified Hot Coal Tar Pitch With 2000% Elongation | SF | 14.19 |