IFB_Drawings.pdf

PDF 11 MB Posted

Attached to
BUILDING M-04 RENOVATION & ADDITION
Solicitation number
C442N4260
Issued by
Iowa

About this file

This is an Invitation for Bid (IFB) drawings document prepared by the Iowa Department of Public Defense for the renovation and expansion of Building M-04. The project involves the renovation of an existing 3,530 square-foot masonry and wood-framed structure and construction of a new 737 square-foot addition. Bids are due September 24, 2026, at 2:00 p.m. CDT and must be submitted as numerical lump-sum bids and unit-price line items through the IMPACS event system. The project includes a Base Bid for the overall project scope and a Unit Price item for masonry repointing work priced per square foot. Bidders must submit all required documentation, including a Tribal Set-Aside Form, through the buyer attachments section of the solicitation portal.

The project is subject to all federal Buy American (BABA) requirements that bidders must comply with during execution. Payment terms require the State of Iowa sixty days to process invoices pursuant to Iowa Code 8A.514. Bidders must certify their bids, authorize release of bid information, acknowledge RFB definitions, accept federal terms and conditions, and provide evidence of required insurance coverage as outlined in the solicitation documents. The RFB number is C442N4260. Philip Payton serves as the issuing officer and can be contacted at 515-975-6211 or philip.payton@dpd.iowa.gov for questions regarding the opportunity.

View the file

Other files

File Type Posted
Specifications.pdf PDF
Advertisement.pdf PDF
Supplement D - Targeted Small Business Form.html HTML file
1443142-event.pdf PDF
Supplement F - Substitution Request Form (Bidding Phase).html HTML file
Form of Agreement Between the Owner and Contractor.html HTML file
Supplement G - Proposed Subcontractor Form.html HTML file
General Conditions.html HTML file
Performance and Payment Bond.html HTML file
Supplementary Conditions.html HTML file
IFB_Specifications.pdf PDF
Supplement J - 889 Representation Form.html HTML file
Form_of_Bid.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M-06

M-01 M-02

M-03

M-10

M-09

M-08

M-07

M-05

M-04

M-15 M-11

M-12M-13

M-04

ADDITION

0' 8'

0' 3"

6" 1'

0' 6"

1' 2'

0' 6"

1' 2'

0' 1'

2' 4'

0' 1'

2' 4'

8' 0'

2' 4'

8'

0'

4' 8'

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

1/ 8"

'-0

1/ 4"

'-0

1/ 2"

'-0

3/ 4"

'-0

1"

'-0

A

1/

2"

'-0

30x42 9 10

1/

'-0

3"

'-0

B

C

D

E

F

G

H

87654321

9 1087654321

9/ 9/

:1

6:

P M

C :\U se rs

\M C ol e\

D oc um en ts \2

BU

IL

D

IN

G

M -0

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

AR

C

H _m co le

K4 2B

9.

rv t

ISSUE FOR BID

BU

IL

D

IN

G M

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

JO

H

N

ST

O N

, I A

1-

COVER SHEET

C

AM

P D

O D

G E

N W

0T

H A

VE

N

U E

IO

W

A

AR

M Y

N

AT

IO

N

AL

G

U

AR

D

G-001

23067

CONTRACT: C442N4260 | PROJ: 19082943

09.09.2026

C O

N

TR

AC

T:

C

2N

PR

O

J:

IOWA ARMY NATIONAL GUARD

BUILDING M4 RENOVATION & ADDITION

PROJECT NUMBER: 19082943 | CONTRACT NUMBER: C442N4260

I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly licensed

Architect under the laws of the State of Iowa.

Signature

License number

Pages or sheets covered by this seal

Date

MATTHEW A. COLE, AIA

My license renewal date is

ALL ARCHITECTURAL SHEETS

JUNE 30, 2028

I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed

Professional Engineer under the laws of the State of Iowa.

Signature

My license renewal date is Pages or sheets covered by this seal

Date

License number

HOLLY H. ELBERT, P.E.

DECEMBER 31, 2027

17968

ALL MECHANICAL SHEETS

I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed

Professional Engineer under the laws of the State of Iowa.

Signature

My license renewal date is Pages or sheets covered by this seal

Date

License number

ROBERT A. HEDGEPETH, P.E.

DECEMBER 31, 2027

14212

ALL ELECTRICAL SHEETS

I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed

Professional Engineer under the laws of the State of Iowa.

Signature

My license renewal date is Pages or sheets covered by this seal

Date

License number

ALL STRUCTURAL SHEETS

ERIK RAKER, P.E.

DECEMBER 31, 2027

17922

I hereby certify that this engineering document was prepared by me or under my direct supervision and that I am a duly licensed

Professional Engineer under the laws of the State of Iowa.

Signature

My license renewal date is Pages or sheets covered by this seal

Date

License number

ALL CIVIL SHEETS

JUSTIN STROM

DECEMBER 31, 2027

P24140

PROFESSIONAL SEALS

VICINITY PLAN

NN

NN1" = 200'

KEY PLAN

M-12M-07

M-06

M-05

M-15

M-08

M-09

M-10

M-11

M-13M-02

M -0

M

-0

M-04

SHEET LIST

G-001 COVER SHEET

G-002 ARCHITECTURAL LEGEND

G-003 MEP LEGEND

G-100 CODE ANALYSIS

C100 TITLE SHEET

C101 PROJECT INFORMATION

MS101 MECHANICAL SITE PLAN AND DETAILS

C200 DEMOLITION PLAN

C300 DIMENSION PLAN

C400 GRADING AND EROSION CONTROL PLAN

S-001 STRUCTURAL NOTES

S-101 FOUNDATION AND ROOF FRAMING DETAILS

AD101 DEMOLITION PLAN AND REFLECTED CEILING PLAN

A-101 FLOOR PLAN AND SCHEDULES

A-102 ROOF PLAN

A-131 REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-311 WALL TYPES AND DETAILS

A-401 INTERIOR ELEVATIONS

A-501 DETAILS

PL100 UNDERFLOOR PLUMBING PLANS

PL101 ABOVE FLOOR PLUMBING PLANS

P-601 PLUMBING DETAILS AND SCHEDULES

MH101 MECHANICAL HVAC PLANS

MP101 MECHANICAL PIPING PLAN

M-401 MECHANICAL HVAC ATTIC PLAN AND ENLARGED PLANS

M-501 MECHANICAL DETAILS

M-502 SEQUENCES OF OPERATION

M-601 MECHANICAL SCHEDULES

ED101 ELECTRICAL DEMOLITION

ES100 ELECTRICAL SITE PLAN

E-101 POWER & FIRE ALARM PLAN

E-501 ELECTRICAL DETAILS & SCHEDULES

EL101 LIGHTING PLAN

ET101 TELECOM & AV PLAN

GENERAL

SITE

CIVIL DEMOLITION

CIVIL

STRUCTURAL

ARCHITECTURAL DEMOLITION

ARCHITECTURAL

PLUMBING

MECHANICAL - HVAC

MECHANICAL - PIPING

MECHANICAL

ELECTRICAL DEMOLITION

ELECTRICAL SITE

ELECTRICAL - LIGHTING

ELECTRICAL - TELECOM

ELECTRICAL

AB

AC

ACI

ACT

AD-#

ADJ

AE-#

AF-#

AFF

AFG

AGG

AHU

AHU-#

AIC

ALT

ALUM

AMP

ANCH

ANSI

APPROX

ARCH

AS REQ'D

ASD

ASHRAE

ASTM

ATS

ATTEN

ANCHOR BOLT

ALTERNATING CURRENT

AMERICAN CONCRETE INSTITUTE

ACOUSTICAL CEILING TILE

AREA DRAIN - (MECH)

ADJACENT

AIR ELIMINATION DEVICE

AIR FITTING

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AGGREGATE

AIR HANDLING UNIT - (ARCH)

AIR HANDLING UNIT - (MECH)

AMPS INTERRUPTING CAPACITY

ALTERNATE

ALUMINUM

AMPERE

ANCHOR

AMERICAN NATIONAL STANDARDS

INSTITUTE

APPROXIMATE

ARCHITECTURAL

AS REQUIRED

ALLOWABLE STRESS DESIGN

AMERICAN SOCIETY OF

HEATING, REFRIGERATING, &

AIR CONDITIONING ENGINEERS

AMERICAN SOCIETY FOR

TESTING & MATERIALS

AUTOMATIC TRANSFER SWITCH

ATTENUATION

B-#

BB

BD

BFA-#

BFU-#

BLDG

BLK

BLKG

BM

BM

BOC

BOT

BRG

BTU

BTUH

BUR

BOILER

BALLED AND BURLAPPED

BOARD

BACKFLOW ASSEMBLY

BOILER FEED UNIT

BUILDING

BLOCK

BLOCKING

BENCH MARK (ARCH, CIVIL)

BEAM (STRUC)

BOTTOM OF CURB

BOTTOM

BEARING

BRITISH THERMAL UNIT

BRITISH THERMAL UNIT PER HOUR

BUILT-UP ROOFING

STANDARD ABBREVIATIONS

A

B

C C-#

CAB

CB

CB-#

CCTV

CCW-#

CDX-#

CF-#

CFM

CFOI

CG

CH-#

CHC

CHKBD

CI

CIP

CJ

CKT

C/B

CLG

CLR

CMT

CMU

CNTR

CO

COL

COMM

CON-#

CONC

CONST

CONT

COORD

CORR

CPH-#

CPT

CPTT

CR

CR-#

CRE-#

CRH-#

CRI-#

CRP-#

CRU-#

CSK

CT

CT

CT-#

CTR

CU-#

CUH

CUH-#

CW

CONDUIT (ELEC)

CONDENSER (MECH)

CABINET

CATCH BASIN (ARCH)

CATCH BASIN (MECH)

CLOSED CIRCUIT TELEVISION

CHILLED WATER COIL

COIL, DX

CARBON DIOXIDE FITTING

CUBIC FEET PER MINUTE

CONTRACTOR FURNISHED, OWNER

INSTALLED

CORNER GUARD

CHILLER

COIL, HEATING

CHALK BOARD

CAST IRON

CAST IN PLACE

CONTROL JOINT

CIRCUIT

CIRCUIT BREAKER

CEILING

CLEAR

CERAMIC MOSAIC TILE

CONCRETE MASONRY UNITY

COUNTER

CLEAN OUT

COLUMN

COMMUNICATION

CONVECTOR

CONCRETE

CONSTRUCTION

CONTINUOUS

COORDINATE, COORDINATED

CORRIDOR

COIL, PREHEAT

CARPET

CARPET TILE

COLD ROLLED (STRUC)

CARD READER (ELEC)

COIL, EXHAUST RECLAIM

COIL, REHEAT

COIL, INTAKE RECLAIM

CONDENSATE RETURN PUMP

COMPUTER ROOM UNITY

COUNTERSINK

CERAMIC TILE (ARCH)

CURRENT TRANSFORMER (ELEC)

COOLING TOWER (MECH)

CENTER, CENTERED

CONDENSING UNIT

CABINET UNIT HEATER (ARCH)

CABINET UNIT HEATER (MECH)

COLD WATER, DOMESTIC

C

DA-#

DBL

DC

DC-#

DD-#

DDC

DEMO

DEPT

DF

DF-#

DIA

DIAG

DIM

DISP

DN

DWG

DS

DTL

DWC-#

DWH-#

DEAERATOR

DOUBLE

DIRECT CURRENT (ELEC)

DRY COOLER (MECH)

DECK DRAIN

DIRECT DIGITAL CONTROL

DEMOLITION

DEPARTMENT

DRINKING FOUNTAIN (ARCH)

DRINKING FOUNTAIN (MECH)

DIAMETER

DIAGONAL

DIMENSION

DISPENSER

DOWN

DRAWING

DOWNSPOUT

DETAIL

DRINKING WATER CHILLER (MECH)

DOMESTIC WATER CHILLER (MECH)

D

E

EA

EC-#

ECB

ED-#

EEW-#

EF

EF-#

EFC-#

EIFS

EJ

ELEV

EMERG

ENAM

ENCL

EP

EQ

EQUIP

ES-#

ET-#

EVC-#

EW

EW-#

EWC

EWC-#

EWS-#

EXH

EXIST

EXP

EXPS

EXT

ELECTRICAL

EACH

EXHAUST, CEILING MOUNTED

ENCLOSED CIRCUIT BREAKER (ELEC)

EXHAUST, DUCT MOUNTED

EMERGENCY EYE WASH

EACH FACE

EXHAUST, FLOOR MOUNTED

EVAPORATIVE FLUID COOLER

EXTERIOR INSULATION & FINISH SYSTEM

EXPANSION JOINT

ELEVATION

EMERGENCY

ENAMEL

ENCLOSURE

ELECTRICAL PANELBOARD

EQUAL

EQUIPMENT

EMERGENCY SHOWER

EXPANSION TANK

EVAPORATIVE CONDENSER

EACH WAY (STRUC)

EXHAUST, WALL MOUNTED (MECH)

ELECTRIC WATER COOLER (ARCH)

ELECTRIC WATER COOLER (ELEC)

EMERGENCY WASH STATION

EXHAUST

EXISTING

EXPANSION

EXPOSED

EXTERIOR

E

F-#

FA

FACP

FB-#

FC-#

FCU

FCU-#

FD

FD-#

FDN

FE

FE-#

FEC

FH

FH

FHC

FIN

FIXT

FL

FLASH

FLEX

FLG

FLOUR

FLR

FO

FPC-#

FPS

FPT-#

FR-#

FS-#

FSK-#

FT

FTG

FTR-#

FURR

FURNACE

FUSED AT

FIRE ALARM CONTROL PANEL

FILTER/FILTER BANK

FAN, CEILING MOUNTED

FAN COIL UNIT (ARCH)

FAN COIL UNIT (MECH)

FLOOR DRAIN (ARCH)

FLOOR DRAIN (MECH)

FOUNDATION

FIRE EXTINGUISHER

FAN, EXHAUST (MECH)

FIRE EXTINGUISHER CABINET

FIRE HYDRANT (CIVIL)

FLAT HEAD (STRUC)

FIRE HOSE CABINET

FINISH FLOOR

FIXTURE

FLOW LINE

FLASHING

FLEXIBLE

FLANGE (STRUC)

FLUORESCENT

FLOOR

FIBER OPTIC

FIRE PROTECTION CABINET

FEET PER SECOND

FAN POWERED TERMINAL

FAN, RELIEF

FAN, SUPPLY

FLOOR SINK

FEET/FOOT

FOOTING

FINNED TUBE RADIATOR

FURRING

F

G

G, GND

GA

GALV

GB

GC

GF-#

GFI

GL

GPM

GYP

GYP BD

GAS

GROUND

GAGE

GALVANIZED

GRADE BEAM

GENERAL CONTRACTOR

GAS FITTING

GROUND FAULT INTERRUPTER

GLASS

GALLONS PER MINUTE

GYPSUM

GYPSUM WALLBOARD

G

H-#

HB

HB-#

HC

HDWD

HDWR

HEX-#

HM

HOA

HORIZ

HP

HP

HP-#

HSS

HT

HTG

HTR

HW

HY

HZ

HUMIDIFIER

HOSE BIB (ARCH)

HOSE BIB (MECH)

HOLLOW CORE

HARDWOOD

HARDWARE

HEAT EXCHANGER

HOLLOW METAL

HAND OFF AUTOMATIC

HORIZONTAL

HIGH POINT (CIVIL, STRUCT)

HORSEPOWER (MECH)

HOUR

HOLLOW STRUCTURAL SHAPE

HEIGHT

HEATING

HEATER

HOT WATER, DOMESTIC

HYDRANT

HERTZ

H

IBC

ID

IG

IN

INSUL

INV

INTERNATIONAL BUILDING CODE

INSIDE DIAMETER

ISOLATED GROUND

INCH

INSULATION, INSULATED

INVERT

I

JAN

JB

JST

JT

JANITOR

JUNCTION BOX

JOIST

JOINT

J

KCMIL

KO

KVA

KW

THOUSAND CIRCULAR MILL

KNOCK OUT

KILOVOLT AMPERES

KILOWATTS

K

L-#

LAM

LAV

LCP

LDC

LGMF

LLH

LLV

LP

LP

LRFD

LT WT CON

LT-#

LVR

LVT

LAVATORY (MECH)

LAMINATE

LAVATORY (ARCH)

LIGHTING CONTROL PANEL

LOAD DISTRIBUTION CABINET

LIGHT GAGE METAL FRAMING

LONG LEG HORIZONTAL

LONG LEG VERTICAL

LOW POINT (CIVIL, STRUCT)

LIQUID PETROLEUM GAS (MECH)

LOAD & RESISTANCE FACTOR DESIGN

LIGHT WEIGHT CONCRETE

LAVATORY TRIM

LOUVER

LUXURY VINYL TILE

L

MACH

MAN

MAU-#

MAX

MB

MB-#

MCC-#

MDF

MDO

MECH

MEMB

MEZZ

MFG

MH

MH-#

MIN

MISC

MO

MPH

MS

MTC

MTD

MTL

MTR

MUL

MACHINE

MANUAL

MAKE-UP AIR UNIT

MAXIMUM

MOP BASIN (ARCH)

MOP BASIN (MECH)

MOTOR CONTROL CENTER

MEDIUM DENSITY FIBERBOARD

MEDIUM DENSITY OVERLAY

MECHANICAL

MEMBRANE

MEZZANINE

MANUFACTURER

MANHOLE (ARCH)

MANHOLE (MECH)

MINIMUM

MISCELLANEOUS

MASONRY OPENING

MILES PER HOUR

MOTOR STARTER

EMPTY CONDUIT

MOUNTED

METAL

MOTOR

MULLION

M

N, NEUT

N/A

NC

NEC

NF

NFPA

NIC

NO

NO

NOM

NTS

NEUTRAL

NOT APPLICABLE

NORMALLY CLOSED

NATIONAL ELECTRIC CODE

NON FUSED

NATIONAL FIRE PROTECTION

ASSOCIATION

NOT IN CONTRACT

NORMALLY OPEN (ELEC)

NUMBER (GENERAL)

NOMINAL

NOT TO SCALE

N

OA

OC

OD

OD-#

OFCI

OFOI

OH

OPNG

OPP

OSB

OVER ALL

ON CENTER

OUTSIDE DIAMETER

OVERFLOW DRAIN (MECH)

OWNER FURNISHED,

CONTRACTOR INSTALLED

OWNER FURNISHED,

OWNER INSTALLED

OVERHEAD

OPENING

OPPOSITE

ORIENTED STRAND BOARD

O

PCD-#

PCH-#

PCI

PCW-#

PDI-#

PDR-#

PDU-#

PF

PF-#

PFO-#

PHP-#

PHR-#

PHW-#

PIR-#

PL

PL

PLAM

PLYWD

PNL

PPB-#

PR

PRA-#

PRC-#

PRI

PRO-#

PRV-#

PSE-#

PSF

PSI

PST-#

PT

PT

PTN

PVC

PWR

PUMP, CONDENSATE DRAIN

PUMP, CHILLED WATER

PRECAST CONCRETE INSTITUTE

PUMP, CONDENSER WATER

PUMP, DEIONIZED WATER

PUMP, DRINKING WATER - DOMESTIC

POWER DISTRIBUTION UNIT

POWER FACTOR

FIRE PUMP

PUMP, FUEL OIL SYSTEM

PUMP, HEAT PUMP SYSTEM

PUMP, DOMESTIC WATER RECIRCULATING

PUMP, HEATING WATER

PUMP, IRRIGATION

PILOT LIGHT (ELEC)

PLATE (STRUC, ARCH)

PLASTIC LAMINATE

PLYWOOD

PANEL

PUMP, DOMESTIC PRESSURE BOOSTER

PAIR

PRESSURE REDUCING ASSEMBLY

PUMP, RECLAIM SYSTEM

PRIMARY

PUMP, REVERSE OSMOSIS

PRESSURE RELEASE VALVE

PUMP, SANITARY SEWAGE EJECTOR

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PUMP, STORM AND FOOTING DRAIN SUMP

POTENTIAL TRANSFORMER (ELEC)

POINT

PARTITION

POLYVINYL CHLORIDE

POWER

P

QT QUARRY TILE

Q

R R

RA

RB

RC

RC-#

RCP

RCP

RD

RD-#

RDR-#

REBAR

REF

REQ'D

RESIL

RF-#

RHW

RND

RO

RTU

RTU-#

RADIUS

RISER(S)

RETURN AIR

RESILIENT BASE

RESILIENT COVE BASE

RETURN, CEILING MOUNTED

REINFORCED CONCRETE PIPE (MECH)

REFLECTED CEILING PLAN (ARCH)

ROOF DRAIN (ARCH)

RETURN, DUCT MOUNTED

ROOF DRAIN RECEIVER

REINFORCING BAR

REFERENCE, REFER

REQUIRED

RESILIENT

RETURN, FLOOR MOUNTED

RECIRCULATING HOT WATER, DOMESTIC

ROUND

ROUGH OPENING

ROOF TOP UNIT (ARCH)

ROOF TOP UNIT (MECH)

R

S-#

SA

SA-#

SC-#

SCHED

SD-#

SECT

SF-#

SG-#

SH-#

SHT

SHT-#

SHTG

SIM

SPEC

SQ

SS

SS-#

ST-#

STD

STL

STRUC

SURF

SUSP

SW-#

SWBD

SWGR

SINK (MECH)

SUPPLY AIR

SOUND ATTENUATOR

SUPPLY, CEILING MOUNTED

SCHEDULE

SUPPLY, DUCT MOUNTED

SECTION

SUPPLY, FLOOR MOUNTED

STEAM GUN

SHOWER

SHEET (ARCH, STRUC)

SHOWER TRIM (MECH)

SHEATHING

SIMILAR

SPECIFICATION(S)

SQUARE

STAINLESS STEEL (ARCH) OR SANITARY

SEWER

SERVICE SINK (MECH)

SINK TRIM

STANDARD

STEEL

STRUCTURAL

SURFACE

SUSPENDED

SUPPLY, WALL MOUNTED

SWITCHBOARD

SWITCHGEAR

S

T T & G

TC-#

TD-#

TEL

TELECOM

TERR

TF

TF-#

THRU

TKBD

TOB

TOC

TOS

TS

T'STAT

TW-#

TYP

TREAD(S)

TONGUE AND GROOVE

TRANSFER GRILLE, CEILING MOUNTED

TRENCH DRAIN

TELEPHONE

TELECOMMUNICATIONS

TERRAZZO

TOP FLANGE (STRUC)

TRANSFER GRILLE, FLOOR MOUNTED

THROUGH

TACKBOARD

TOP OF BEAM

TOP OF CURB, TOP OF CONCRETE

TOP OF FOOTING

TOP OF STEEL

THERMOSTAT

TRANSFER GRILLE, WALL MOUNTED

TYPICAL

T

UH-#

UMC

UNO

UPC

UPS

UR-#

UNIT HEATER

UNIFORM MECHANICAL CODE

UNLESS NOTED OTHERWISE

UNIFORM PLUMBING CODE

UNINTERRUPTIBLE POWER SUPPLY

URINAL

U

V V

VA

VAE-#

VAR-#

VAS-#

VAV

VB

VCP

VCT

VDT

VER

VERT

VEST

VF-#

VFD-#

VSF

VTR

VWC

VOLT(S) (ELEC)

VENT (MECH)

VOLT AMPERE

VARIABLE AIR EXHAUST TERMINAL UNIT

VARIABLE AIR RETURN TERMINAL UNIT

VARIABLE AIR SUPPLY TERMINAL UNIT

VARIABLE AIR VOLUME

VINYL BASE

VITRIFIED CLAY PIPE

VINYL COMPOSITION TILE

VIDEO DISPLAY TERMINAL

VERIFY

VERTICAL

VESTIBULE

VACUUM FITTING

VARIABLE FREQUENCY DRIVE

VINYL SHEET FLOORING

VENT THRU ROOF

VINYL WALL COVERING

V

W W W/ W/O

WC-#

WD

WH

WH-#

WR

WT

WWF

WASTE (MECH)

WATTS (ELEC)

WITH

WITHOUT

WATER CLOSET

WOOD

WATER HEATER (ARCH)

WALL HYDRANT (MECH)

WATER RESISTANT

WEIGHT

WELDED WIRE FABRIC

W

STANDARD SYMBOLS

STANDARD MATERIALS LEGEND

12.22

12.22

12.22

12.22

1A

12.22

12.22

1A

2A

3A

4A

DETAIL

1/8" = 1'-0"

0' 2' 4' 8' 16'

SECTION MARK - SEE

SECTION 1 ON

SHEET 12.22

SECTION MARK - SEE

SECTION 1 ON

SHEET 12.22 -

DIRECTIONAL

DETAIL MARK - SEE

DETAIL 1 ON

SHEET 12.22

DETAIL MARK

WITH BUBBLE - SEE

DETAIL 1 ON

SHEET 12.22

ELEVATION MARK - SEE

ELEVATION 1 ON

SHEET 12.22

ELEVATION MARK - SEE

ELEVATION 1A, 2A, ETC. ON

SHEET 12.22

DRAWING TITLE -

NUMBER, NAME, AND

SCALE

GRAPHICAL SCALE

BREAK LINES

DATUM POINTSECOND LEVEL

12' - 5 1/2"

REVISION BUBBLE AND

REVISION TAG

SHEET NOTE MARK

WITH LEADER

A1

WOOD

INSULATION

FINISHES

PARTITION INDICATIONS

ELEVATION INDICATIONS

FINISHED WOOD

BATT OR LOOSE FILL

METAL STUD

CERAMIC TILE

CERAMIC TILE

RIGID INSULATION

STRUCTURAL GLASS

WOOD BLOCKING -

CONTINUOUS

WOOD BLOCKING -

DISCONTINUOUS

PLYWOOD -

LARGE SCALE

MEDIUM DENSITY

FIBERBOARD

THIS IS A MASTER LIST. ALL ITEMS LISTED MAY NOT BE APPLICABLE TO THIS PARTICULAR PROJECT.

1B

WINDOW TAG

DOOR TAG

OFFICE

206 ROOM TAG -

ROOM NAME AND

ROOM NUMBER

FLOOR DRAIN

BRICK

PLYWOOD -

SMALL SCALE

KEY NOTE MARK

WITH LEADER

XXXXX.X

WALL TYPE TAG

ACOUSTIC

CEILING TILE

GYPSUM BOARD

FOAMED IN PLACE

INSULATION

TROFFER LIGHT FIXTURE

RECESSED LIGHT FIXTURE

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER

EXHAUST FAN

EXIT LIGHT

OCCUPANCY SENSOR

SMOKE DETECTOR

FIRE ALARM STROBE

SPRINKLER HEAD

S

OS

SECURITY CAMERA

PAGING SPEAKERS

WIRELESS ACCESS POINT

MD MOTION DETECTOR

WAP

ARCHITECTURAL LEGEND

EARTHWORKS

CONCRETE

MASONRY

METAL

EARTH /

COMPACT FILL

CONCRETE

FACE BRICK

STEEL /

OTHER METALS

CONCRETE

MASONRY UNIT

ALUMINUM

SAND

PRECAST CONCRETE

A1

SPOT ELEVATION12' - 5 1/2"

DEMOLITION GENERAL NOTES

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

SCREENED (GRAY-TONE) LINES INDICATE EXISTING

CONSTRUCTION TO REMAIN.

BOLD DASHED LINES INDICATE EXISTING

CONSTRUCTION TO BE REMOVED.

FIELD VERIFY EXISTING BUILDING CONDITIONS,

ELEVATIONS, AND DIMENSIONS PRIOR TO START

OF WORK. NOTIFY ARCHITECT OF ANY

DISCREPANCIES FOUND IN RELATION TO THE

CONTRACT DOCUMENTS.

GENERAL CONTRACTOR SHALL COORDINATE

WORK OF ALL TRADES PRIOR TO STARTING ANY

DEMOLITION/CONSTRUCTION.

DO NOT SCALE DRAWINGS TO DETERMINE

DIMENSIONS. VERIFY ALL DIMENSIONS AND

IMMEDIATELY REPORT ANY DISCREPANCIES TO

THE ARCHITECT.

PERFORM DEMOLITION WITHOUT DAMAGE TO

ADJACENT RETAINED CONSTRUCTION. WHERE

SUCH DAMAGE OCCURS, PATCH, REPAIR, OR

OTHERWISE RESTORE TO ITS ORIGINAL

CONDITION.

PATCH AND REPAIR ALL OPENINGS AND VOIDS

LEFT BY REMOVAL OF EXISTING CONSTRUCTION,

EQUIPMENT, PIPING, DUCTS, CONDUIT, ETC. AS

REQUIRED TO MATCH ADJACENT.

PROTECT FROM DAMAGE ALL EXISTING

CONSTRUCTION TO REMAIN.

MAINTAIN THE BUILDING IN A WEATHER TIGHT

CONDITION AT ALL TIMES.

REFER TO AND COORDINATE WITH MECHANICAL,

PLUMBING, AND ELECTRICAL DRAWINGS FOR

EXTENT OF ASSOCIATED DEMOLITION AND NEW

WORK.

MAINTAIN OPERATION OF ALL EXISTING SERVICES

AND UTILITIES TO THE BUILDING. COORDINATE ANY

DISRUPTIONS OR DISCONTINUATIONS WITH THE

OWNER'S REPRESENTATIVE IN ADVANCE.

PROVIDE TEMPORARY SHORING AS REQUIRED FOR

SELECTIVE DEMOLITION.

CONSULT ARCHITECT/STRUCTURAL ENGINEER FOR

ANY AND ALL LOCATIONS WHERE UNFORESEEN OR

UNUSUAL STRUCTURAL CONDITIONS EXIST.

UNLESS SPECIFICALLY INDICATED OTHERWISE,

REMOVE ALL DEMOLISHED MATERIALS FROM THE

SITE AND FOLLOW IOWA DNR AND LANDFILL

PROCEDURES TO PROPERLY SEPARATE AND

DISPOSE OF MATERIALS REMOVED FROM THE SITE.

PROVIDE ALL DEMOLITION AND DISPOSAL AS

REQUIRED FOR INSTALLATION OF NEW WORK AS

INDICATED, OR AS REASONBLY IMPLIED BY THESE

CONSTRUCTION DOCUMENTS.

STORE AND PROTECT ALL SALVAGED ITEMS

NOTED OR REQUESTED TO BE RETURNED TO

OWNER. COORDINATE WITH OWNER FOR THE

LOCATION OF STORAGE FOR SALVAGED ITEMS.

GENERAL NOTES

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

SCREENED (GRAY-TONE) LINES INDICATE EXISTING

CONSTRUCTION TO REMAIN.

BOLD SOLID LINES INDICATE NEW CONSTRUCTION.

FIELD VERIFY EXISTING BUILDING CONDITIONS,

ELEVATIONS, AND DIMENSIONS PRIOR TO START

OF WORK. NOTIFY ARCHITECT OF ANY

DISCREPANCIES FOUND IN RELATION TO THE

CONTRACT DOCUMENTS.

GENERAL CONTRACTOR SHALL COORDINATE

WORK OF ALL TRADES PRIOR TO STARTING ANY

DEMOLITION/CONSTRUCTION.

DO NOT SCALE DRAWINGS TO DETERMINE

DIMENSIONS. VERIFY ALL DIMENSIONS AND

IMMEDIATELY REPORT ANY DISCREPANCIES TO

THE ARCHITECT.

PROTECT FROM DAMAGE ALL EXISTING

CONSTRUCTION TO REMAIN.

MAINTAIN THE BUILDING IN A WEATHER TIGHT

CONDITION AT ALL TIMES.

ALL DIMENSIONS ARE GIVEN TO THE FACE OF

FINISHED SURFACE, UNLESS NOTED OTHERWISE.

+/- DIMENSIONS ALLOW FOR VARIATION DUE TO

EXISTING CONDITIONS.

ALL DIMENSIONS TO EXISTING STRUCTURE/WALLS

ARE APPROXIMATE. CONTRACTOR SHALL FIELD

VERIFY.

REFER TO AND COORDINATE WITH MECHANICAL,

PLUMBING, AND ELECTRICAL DRAWINGS FOR

EXTENT OF ASSOCIATED DEMOLITION AND NEW

WORK.

MAINTAIN OPERATION OF ALL EXISTING SERVICES

AND UTILITIES TO THE BUILDING. COORDINATE ANY

DISRUPTIONS OR DISCONTINUATIONS WITH THE

OWNER'S REPRESENTATIVE IN ADVANCE.

PATCH AND REPAIR ALL SURFACES ADJACENT TO

DEMOLISHED ITEMS AS REQUIRED TO MATCH

EXISTING OR NEW ADJACENT CONSTRUCTION.

PATCH AND REPAIR ALL OPENINGS AND VOIDS

LEFT BY REMOVAL OF EXISTING CONSTRUCTION,

EQUIPMENT, PIPING, DUCTS, CONDUIT, ETC. AS

REQUIRED TO MATCH ADJACENT.

CONSULT ARCHITECT/STRUCTURAL ENGINEER FOR

ANY AND ALL LOCATIONS WHERE UNFORESEEN OR

UNUSUAL STRUCTURAL CONDITIONS EXIST.

PROVIDE BLOCKING AS REQUIRED IN WALLS FOR

ALL BASE AND WALL CABINETS,

TELEVISIONS/MONITORS, WALL-HUNG EQUIPMENT,

RESTROOM ACCESSORIES WALL-APPLIED DOOR

HARDWARE AND OWNER-PROVIDED EQUIPMENT.

CENTER ALL DEVICES, LIGHT FIXTURES, AND

SPRINKLER HEADS EACH WAY WITHIN LAY-IN

CEILING PANELS UNLESS NOTED OTHERWISE.

0' 8'

0' 3"

6" 1'

0' 6"

1' 2'

0' 6"

1' 2'

0' 1'

2' 4'

0' 1'

2' 4'

8' 0'

2' 4'

8'

0'

4' 8'

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

1/ 8"

'-0

1/ 4"

'-0

1/ 2"

'-0

3/ 4"

'-0

1"

'-0

A

1/

2"

'-0

30x42 9 10

1/

'-0

3"

'-0

B

C

D

E

F

G

H

87654321

9 1087654321

9/ 9/

:1

6:

P M

C :\U se rs

\M C ol e\

D oc um en ts \2

BU

IL

D

IN

G

M -0

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

AR

C

H _m co le

K4 2B

9.

rv t

ISSUE FOR BID

BU

IL

D

IN

G M

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

JO

H

N

ST

O N

, I A

1-

ARCHITECTURAL

LEGEND

C

AM

P D

O D

G E

N W

0T

H A

VE

N

U E

IO

W

A

AR

M Y

N

AT

IO

N

AL

G

U

AR

D

G-002

23067

CONTRACT: C442N4260 | PROJ: 19082943

09.09.2026

C O

N

TR

AC

T:

C

2N

PR

O

J:

MASTER KEYNOTE LEGEND

D1 REMOVE ALL EXISTING INTERIOR GYPSUM

WALLS AND FRAMING, INCLUDING EXISTING

INSULATION. PREP AREAS FOR NEW

CONSTRUCTION

D3 DEMOLISH EXISTING ROOF SOFFITS AND

FASCIA

D4 REMOVE EXISTING FLOOR FINISHES,

SUBFLOOR AND WOOD JOIST FLOOR

STRUCTURE

D5 REMOVE EXISTING WINDOW FRAMES,

GLAZING AND SOLID SURFACE WINDOW

SILLS. PREPARE OPENINGS FOR NEW

CONSTRUCTION. PATCH HOLES IN EXTERIOR

MASONRY AS REQUIRED.

D9 DEMO EXISTING CONCRETE SLAB THIS AREA

FOR INSTALLATION OF NEW

PLUMBING/MECHANICAL PIPING.

COORDINATE EXTENTS AND LOCATION WITH

UNDERFLOOR PLUMBING.

D10 CUT AND REMOVE MASONRY AS REQUIRED

TO PROVIDE OPENING FOR NEW WINDOW

D11 REMOVE EXISTING EXTERIOR BUILDING

SIGNAGE AND RETURN TO OWNER

D12 REMOVE EXISTING DOOR AND FRAME

D13 REMOVE EXISTING DOOR AND FRAME.

PREPARE OPENING FOR NEW

CONSTRUCTION

D15 REMOVE EXISTING LIGHT FIXTURE. SEE

ELECTRICAL

D16 DEMOLISH EXISTING CONCRETE AND

MASONRY LANDING, RAMP AND GUARDRAIL.

REMOVE ASSOCIATED FOOTINGS

D17 REMOVE ALL RESTROOM FIXTURES AND

ACCESSORIES. COORDINATE WITH

PLUMBING

D19 REMOVE EXISTING ACT CEILING TILE AND

GRID ENTIRE ROOM

MASTER KEYNOTE LEGEND

N8 PROVIDE 8' CORNER GUARD

N9 TILE TO CARPET TRANSITION STRIP

N10 PROVIDE NEW 24"X24" MOP SINK BASIN WITH

2'-6" STAINLESS STEEL BACK PANELS ON

EAST AND NORTH WALLS

N12 CONNECT NEW DOWNSPOUT TO NEW

UNDERGROUND DRAIN TILE. SEE DETAIL

A6/A-501

N13 INSTALL OWNER PROVIDED BUILDING

SIGNAGE. COORDINATE WITH OWNER FOR

LOCATION AND MOUNTING PROCEDURES

N14 PROVIDE NEW ALUMINUM GABLE VENT

N15 24" X 24" ACT & CEILING GRID

N17 5/8" GYPSUM BOARD CEILING ON METAL

STUDS

N18 PROVIDE NEW WALL BASE ENTIRE ROOM

N20 NEW CUPOLA

N21 EXISTING CONCRETE SILL. PAINT PNT-4 TYP

N22 NEW 8" EXTERIOR CEMENT LAP-BOARD TRIM

AND SIDING. PRE-FINISHED TRIM COLOR:

ARCTIC WHITE, SIDING COLOR: PNT-3.

N23 PRE-FINISHED METAL FASCIA AND VENTED

SOFFIT. COLOR: WHITE (TYP)

N24 EXISTING ASPHALT SHINGLES TO REMAIN

N25 PROVIDE TUCK-POINTING OF EXISTING

MASONRY AS REQUIRED IN THIS LOCATION

N26 LOUVER - SEE MECHANICAL

N27 PATCH AND REPAIR ALL EXISTING HOLES

AND FORMER UTILITY PENETRATIONS

ENTIRE ELEVATION. USE METAL PLATE WITH

WATER TIGHT ADHESIVE SEAL FOR

PENETRATIONS LARGER THAN 3". USE

GROUT FILL FOR ALL OTHER. CLEAN ENTIRE

ELEVATION

N29 NEW CONCRETE SILL. MATCH EXISTING SIZE

AND PROFILE. PAINT PNT-4 TYP

N30 COORDINATE MECHANICAL DUCT

PENETRATIONS IN NEW WALL.

MASTER KEYNOTE LEGEND

N31 PROVIDE RADIUSED (BULL-NOSE) EDGE AT

ALL EXPOSED CORNERS AND JAMBS AT

INTERIOR MASONRY

N32 PROVIDE BLOCKING FOR WALL HUNG

MECHANICAL EQUIPMENT. COORDINATE

LOCATION WITH MECHANICAL.

N34 EXISTING ROOF VENT TO REMAIN

N35 OWNER PROVIDED FURNISHING

N36 SOLID SURFACE WINDOW SILL. SEE SECTION

09 06 00 SCHEDULE OF FINISHES

N37 NEW HOUSEKEEPING PAD. COORDINATE

WITH MEP

N38 BRICK MASONRY INFILL WITH CMU BACKUP

AT EXISTING OPENING. FIELD VERIFY

EXISTING OPENING. REUSE AND TOOTH IN

SALVAGED BRICK. COORDINATE WITH NEW

MECHANICAL LOUVER.

N39 NEW CONCRETE STOOP

N41 PROVIDE SEALANT JOINT AT NEW CONCRETE

SLAB TRANSITION

N42 5 1/2" FIBER CEMENT TRIM BOARDS. PAINT

PNT-3

N43 OWNER PROVIDED TELEVISION MONITOR.

PROVIDE BLOCKING. COORDINATE WITH

OWNER AND ELECTRICAL FOR REQUIRED

BACKBOX.

N45 EQUIPMENT PAD. COORDINATE EXACT SIZE

AND LOCATION WITH MECHANICAL UNIT

CURB REQUIREMENTS.

N46 MIRROR

N47 WALL MOUNTED SOAP DISPENSER

N48 SURFACE MOUNTED PAPER TOWEL

DISPENSER

N49 COUNTERTOP MOUNTED LAVATORY

N50 TOILET PAPER DISPENSER

N51 FEMININE NAPKIN DISPOSAL

N53 ADA GRAB BAR

N54 NEW GALVANIZED HAND RAIL. EXTEND 12"

MIN AT EACH END. SEE CIVIL. PAINT PNT-3.

MASTER KEYNOTE LEGEND

D20 REMOVE ALL EXISTING GUTTERS AND

DOWNSPOUTS. PROTECT DRAINAGE TILE

INLETS FOR REUSE

D25 REMOVE EXISTING HANDRAILS. PATCH

CONCRETE STAIR AND EXTERIOR MASONRY

WALL WHERE HANDRAILS ARE REMOVED

D29 REMOVE PORTION OF EXISTING MASONRY

WALL AS REQUIRED FOR NEW ADDITION

D30 REMOVE EXISTING GAS METER AND ABOVE

GROUND PIPING. PATCH MASONRY AT PIPE

PENETRATION. REFER TO PLUMBING

D32 REMOVE CONCRETE EQUIPMENT PADS

D34 DEMOLISH PORTION OF EXISTING MASONRY

WALL FOR NEW MECHANICAL DUCTING.

COORDINATE WITH MECHANICAL

D35 REMOVE EXISTING FLOOR FINISH AND WALL

BASE IN THIS ENTIRE ROOM

D36 DEMOLISH EXISTING EXTERIOR VAULT

ACCESS DOOR AND INFILL FOUNDATION

WALL TO MATCH ADJACENT CONSTRUCTION.

D37 DEMOLISH EXISTING VAULT ACCESS WAY

FOUNDATION WALLS TO ALLOW FOR NEW

ADDITION CONSTRUCTION.

D38 REMOVE AND SALVAGE EXISTING PAPER

TOWEL DISPENSER. RETURN TO OWNER.

N1 PROVIDE NEW 4" SEALED CONCRETE

SLAB-ON-GRADE FLOOR WITH WWF6X6 -

W2.1XW2.1 - COORDINATE WITH MEP FOR

INSTALLATION OF UNDER FLOOR PLUMBING

N3 ALUMINUM DOOR THRESHOLD (ADA

COMPLIANT). SET IN SEALANT BED. REFER

TO DETAIL A3/A-501

N4 PRE-FINISHED ALUMINUM GUTTER. SMACNA

STYLE I. COLOR: WHITE (TYP)

N5 NEW CARPET ENTIRE ROOM

N6 INSTALL SEMI-RECESSED FIRE

EXTINGUISHER CABINET

N7 PRE-FINISHED ALUMINUM DOWNSPOUTS - 4

1/2" X 3 1/2". COLOR: WHITE (TYP)

MASTER KEYNOTE LEGEND

N57 NEW ASPHALT SHINGLE ROOF. MATCH

EXISTING

N59 PATCH ROOF SHEATHING, FELT UNDERLAY

AND ASPHALT SHINGLES AT DEMOLISHED

ROOF PENETRATION - SEE MECHANICAL

N60 PROVIDE ICE AND WATER SHIELD BELOW

NEW CUPOLA'S. PATCH SHINGLES AS

REQUIRED FOR CUPOLA INSTALLATION

N61 NEW CARPET REDUCER STRIP

N63 CONNECT NEW DOWNSPOUT TO EXISTING

DRAIN TILE INLET

N64 CMU INFILL AT EXISTING WINDOW. FIELD

VERIFY WINDOW OPENING. COORDINATE

WITH MECHANICAL FOR DUCT

PENETRATIONS

N67 FLOOR MOUNTED ADA WATER CLOSET

N69 NEW EXTERIOR WALL HYDRANT. REFER TO

PLUMBING

N70 NEW EXTERIOR LIGHT FIXTURE. REFER TO

ELECTRICAL

N78 REMOVE EXISTING ALUMINUM LOUVER.

INFILL WITH CMU BLOCKING. PATCH ABOVE

GRADE PENETRATIONS WITH SALVAGED

BRICK. TOOTH IN BRICK. BELOW GRADE

PENETRATIONS WILL ONLY RECEIVE CMU

INFILL

N85 FILL AND SLOPE GRADE AS REQUIRED TO

DIVERT WATER NEW FROM STOOP AND

CONCRETE RAMP

N88 UNDERCOUNTER REFRIDGERATOR - OWNER

PROVIDED

N89 NEW ACCESS LID TO ATTIC. SEE DETAIL

E2/A-501.

N90 CABINET UNIT HEATER. SEE MECHANICAL.

N91 FLOOR DRAIN. SEE MECHANICAL. SLOPE

FLOOR TO DRAIN.

N92 DUCT PENETRATION THROUGH GYP LID.

COORDINATE WITH MECHANICAL. SEE

DETAIL E3/A-501.

MASTER KEYNOTE LEGEND

N93 6' X 4' WHITE/TACK BOARD - OWNER

SUPPLIED/CONTRACTOR INSTALLED

N94 4' X 3' WHITE BOARD - OWNER

SUPPLIED/CONTRACTOR INSTALLED

N95 4' X 3' TACK BOARD - OWNER

SUPPLIED/CONTRACTOR INSTALLED

N96 6' X 4' WHITE BOARD - CONTRACTOR

SUPPLIED/CONTRACTOR INSTALLED

N97 HORIZONTAL LOUVER BLINDS-TYPICAL ALL

WINDOWS

N98 24" COAT RACK AND SHELF

N99 PLASTIC LAMINATE WALL HUNG CABINETS

N100 PLASTIC LAMINATE CASEWORK

N101 SOLID SURFACE COUNTERTOP. SEE

SECTION 09 06 00 SCHEDULE OF FINISHES.

N102 COORDINATE NEW BOILER FLUE ROOF

PENETRATION WITH MECHANICAL. BOOT

AND REPAIR ROOFING.

S1 INSTALL NEW 6' WIDE CONCRETE SIDEWALK.

5" PPC PAVEMENT, LIGHT BROOM FINISH

PERPENDICULAR TO PATH OF TRAVEL, ON

12" COMPACTED SUBGRADE (BASE BID)

S

T

P

FMS

T F

F

A

MPS

MPC

PCD

LWS

LWR

CW

HW

RHW

TW

NP

SS

STO

RO

DI

D

NG

LP

O

A

VAC

FP

SP

MEDIUM PRESSURE STEAM

MEDIUM PRESSURE CONDENSATE

PUMPED CONDENSATE DRAIN

LOOP WATER SUPPLY

LOOP WATER RETURN

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RECIRCULATION

TEMPERED WATER

NON-POTABLE WATER

SANITARY SEWER

STORM SEWER OVERFLOW DRAIN

REVERSE OSMOSIS WATER

DEIONIZED WATER

DRAIN

NATURAL GAS

LIQUIDIFIED PETROLEUM GAS

OXYGEN

COMPRESSED AIR

VACUUM

FIRE PROTECTION WATER

SPRINKLER WATER

FC

FD

CHEMICAL FIRE PROTECTION

DRY FIRE PROTECTION

V

AW

AV

GW

ST

ACID WASTE

ACID WASTE VENT

GREASE WASTE

STORM SEWER

SANITARY SEWER VENT

12"x12" XX

H

T

S

DIFFUSER, SQUARE OR RECTANGULAR CEILING

TYPE - SEE SCHEDULE. ARROW INDICATES

AIRFLOW DIRECITON.

DIFFUSER, LINEAR SLOT TYPE WITH PLENUM

SEE SCHEDULE

DIFFUSER, CIRCULAR TYPE - SEE SCHEDULE

DUCTWORK SHOWING SIZE AND SYSTEM

DUCT SECTION - SUPPLY/ OUTSIDE AIR

DUCT SECTION - RETURN AIR

DUCT SECTION - EXHAUST AIR

BACKDRAFT DAMPER

FIRE DAMPER

COMBINATION FIRE/SMOKE DAMPER

SMOKE DAMPER

MOTORIZED DAMPER

SECURITY BAR

MANUAL DAMPER

FLEXIBLE DUCT

TURNING VANES

HUMIDISTAT CEILING/WALL MOUNT

THERMOSTAT CEILING/WALL MOUNT

TEMPERATURE SENSOR CEILING/WALL MOUNT

PRESSURE SENSOR CEILING/WALL MOUNT

RS

RL

REFRIGERANT SUCTION

REFRIGERANT LIQUID

CD

CHR CHILLED WATER RETURN

CHS

HWS

HWR

CWR

CWS

LPS

LPC

CHILLED WATER SUPPLY

HEATING WATER SUPPLY

HEATING WATER RETURN

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

LOW PRESSURE STEAM

LOW PRESSURE CONDENSATE

CONDENSATE DRAIN

HPS HIGH PRESSURE STEAM

HPC HIGH PRESSURE CONDENSATE

SV STEAM VENT

N NITROGEN

WAP

WAP

PS

A

AS

GFP

NONC

M

NO

V

E N

'X'

LV

MC

OS

OS

DS

DS

PC

VFD

J

J

J

J

D

MD

ATS

W

P

S

S

S

PS

SM

VC

I

IC

M

AV

TV

CTV

AMP

SURFACE MOUNT

LIGHT FIXTURE

WALL (END) MOUNT,

DOUBLE FACE EXIT SIGN

CEILING OR PENDANT MOUNT,

SINGLE FACE EXIT SIGN

ANNOTATIONS

AN UPPER CASE LETTER 'F' FOLLOWED BY SERIES

OF NUMBERS AND/OR LETTERS INDICATES THE

FIXTURE ID, SEE LIGHT FIXTURE SCHEDULE FOR

PRODUCT INFORMATION.

AN UPPERCASE LETTER 'R' FOLLOWED BY A

NUMBER INDICATES THE CONTROL PANEL RELAY #

THE FIXTURE IS CONNECTED TO. LOCATE THE

ASSOCIATED LIGHTING CONTROL RELAY DEVICE

WITHIN THE ROOM FOR PANEL INFORMATION.

A LOWERCASE LETTER INDICATES LOCAL

CONTROL. LOCATE THE ASSOCIATE LIGHTING

CONTROL DEVICES (SWITCHES, POWER PACKS,

OCCUPANCY SENSORS, ETC.) FOR ZONE CONTROL.

RECESSED ROUND

DOWNLIGHT FIXTURE

WALL MOUNT

LIGHT FIXTURE

WALL (FLUSH) MOUNT,

SINGLE FACE EXIT SIGN.

CEILING OR PENDANT MOUNT,

DOUBLE FACE EXIT SIGN

CEILING MOUNTED DUAL HEAD EMERGENCY LIGHT

WALL MOUNTED DUAL HEAD EMERGENCY LIGHT

SINGLE POLE SWITCH

OCCUPANCY SENSOR SWITCH.

LOW VOLTAGE SWITCH

RECESSED TROFFER

LIGHT FIXTURE

SURFACE MOUNT STRIP

LIGHT FIXTURE

UNDER CABINET

LIGHT FIXTURE

SUSPENDED MOUNT

LIGHT FIXTURE

BOLLARD LIGHT

POLE MOUNTED

LIGHT FIXTURE

EXTERIOR WALL PACK

LIGHT FIXTURE

CEILING MOUNTED OCCUPANCY SENSOR

CEILING MOUNTED DAYLIGHTING SENSOR

PHOTOCELL

COMBINATION MOTOR STARTER DISCONNECT

SWITCH

NON-FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

MOTOR STARTER

VARIABLE FREQUENCY DRIVE

EMERGENCY SHUT DOWN PUSHBUTTON

SIMPLEX RECEPTACLE - WALL MOUNTED

SIMPLEX RECEPTACLE - FLOOR MOUNTED

SIMPLEX RECEPTACLE - CEILING MOUNTED

SIMPLEX RECEPTACLE - ABOVE COUNTERTOP

DUPLEX RECEPTACLE - WALL MOUNTED

DUPLEX RECEPTACLE - FLOOR MOUNTED

DUPLEX RECEPTACLE - CEILING MOUNTED

ANNOTATIONS ('X') TYP FOR ALL RECEPTACLE TYPES

• 'WP' - WEATHERPROOF

• 'NL' - RECEPTACLE WITH NIGHT LIGHT

• 'GFCI' - GROUND FAULT

• 'IG' - ISOLATED GROUND

• 'S' - SECURE

DUPLEX RECEPTACLE - ABOVE COUNTERTOP

QUADRAPLEX RECEPTACLE - WALL MOUNTED

QUADRAPLEX RECEPTACLE - FLOOR MOUNTED

QUADRAPLEX RECEPTACLE - CEILING MOUNTED

SPECIAL EQUIPMENT CONNECTION - WALL

MOUNTED

SPECIAL EQUIPMENT CONNECTION - FLOOR

MOUNTED

SPECIAL EQUIPMENT CONNECTION -

CEILING OR EQUIPMENT MOUNTED

JUNCTION BOX - WALL MOUNTED

JUNCTION BOX - FLOOR MOUNTED

JUNCTION BOX - CEILING MOUNTED

JUNCTION BOX - SURFACE OR EQUIPMENT

MOUNTED

ELECTRIC MANHOLE

HAND DRYER

MOTOR DAMPER

HIGH VOLTAGE RECEPTACLE - WALL MOUNTED

DOOR OPENER SWITCH

MULTI-OUTLET ASSEMBLY WITH POWER

RECEPTACLES

ELECTRICAL BRANCH PANELBOARD

(SURFACE/RECESSED)

UNDERFLOOR DUCT

ELECTRICAL SCHEMATIC/GENERAL SYMBOLS

AMMETER

AMMETER SWITCH

AUTOMATIC TRANSFER SWITCH

PHASE CONDUCTORS

CABLE

CIRCUIT MONITORING EQUIPMENT

CT RELAY

DISCONNECT SWITCH

CONNECTION POINT

FAULTED CIRCUIT INDICATOR

FUSE

FUSED DISCONNECT

GENERATOR

GROUND FAULT PROTECTION SYSTEM

GROUNDING ELECTRODE

HIGH VOLTAGE BREAKER

INTERLOCKED NORMALLY OPEN (NO) &

NORMALLY CLOSED (NC) DISCONNECT SWITCHES

LOW VOLTAGE CIRCUIT BREAKER

METER

MOTOR

POTENTIAL TRANSFORMER

POWER METER

POWER TRANSFORMER (DELTA WYE)

PUSHBUTTON SWITCH

SPLICE BOX

UNINTERRUPTIBLE POWER SUPPLY WITH BYPASS

UTILITY FEED

VOLTMETER

WALL MOUNTED DAYLIGHTING SENSOR

TRANSFER SWITCH (N=NORMAL FEED)

(E=EMERGENCY FEED)

QUADRAPLEX RECEPTACLE - ABOVE COUNTERTOP

TRACK LIGHT

AUTOMATIC TRANSFER SWITCH

UTILITY SWITCHBOARD

ANNOTATIONS-(X) DENOTES SWITCH ZONE.

TYPICAL FOR ALL SWITCH TYPES.

FEEDER REFERENCE TAG

LOW VOLTAGE MOMENTARY CONTROL SWITCH

ANNOTATIONS - WP DENOTES WEATHERPROOF,

FA (xA) DENOTES FUSE RATING

SB

INVERTER

RECTIFIER

CONVERTER

VOICE/DATA OUTLET-WALL MOUNTED

VOICE/DATA OUTLET-CEILING MOUNTED

VOICE/DATA OUTLET-FLOOR MOUNTED

ANNOTATIONS ('X') TYP FOR ALL OUTLET TYPES

IDENTIFIES FAR END CABLE PUNCHDOWN

ASSIGNMENT. REFERENCE TELECOM

SCHEDULE

SPEAKER HORN

SPEAKER-CEILING MOUNTED

SPEAKER-WALL MOUNTED

INTERCOM

REMOTE INTERCOM

MICROPHONE

SPEAKER VOLUME CONTROL

AUDIO/VIDEO J-BOX - 2 GANG WITH COVER

TV OUTLET

ANALOG CLOCK - DOUBLE SIDED

ANALOG CLOCK - SINGLE SIDED

DIGITAL CLOCK - SINGLE SIDED

DIGITAL CLOCK - DOUBLE SIDED

AMPLIFIER

SOUND MASKING SPEAKER

PAGING SPEAKER

CABLE TRAY

CLOSED CIRCUIT TV OUTLET

MULTI-OUTLET ASSEMBLY WITH DATA

RECEPTACLES

PUBLIC TELEPHONE

WALL TELEPHONE

J-HOOK COMMUNICATION

PATHWAY

PAGING STATION

WALL MOUNTED OCCUPANCY SENSOR.

WIRELESS ACCESS POINT - CEILING MOUNT

WIRELESS ACCESS POINT - WALL MOUNT

SURGE PROTECTION DEVICE

MOTOR OVERLOAD PROTECTION

RELAY

DISCONNECT SWITCH WITH GROUND FAULT

AUTOMATIC TRANSFER SWITCH - HIGH DETAIL

DIGITAL POWER METER

LOAD BANK

WS

R

GF

x

WP

FA

(x)A

'X' a

F1 R1

'x'

A

A

D

D

(A)

(A)

J J J

EB EMERGENCY BYPASS RELAY

IO LIGHTING DIGITAL INPUT/OUTPUT DEVICE

PP LIGHTING POWER PACK

RC LIGHTING ROOM CONTROLLER

ZC LIGHTING ZONE CONTROLLER

BC NETWORK BRIDGE CONTROLLER

PS PARTITION SENSOR

ELECTRICAL DISTRIBUTION PANELBOARD

RECESSED SQUARE

DOWNLIGHT FIXTURE

TYPICAL FOR ALL EXIT SIGNS. ARROWS

INDICATE DIRECTION OF TRAVEL. SHADED

REGION INDICATES SIGN WITHOUT ARROWS.

TYPICAL FOR ALL LIGHT FIXTURES. A SHADED

REGION INDICATES THE FIXTURE IS PART OF

THE EMERGENCY EGRESS LIGHTING SYSTEM.

R LIGHTING CONTROL RELAY

R

LP-XX

R#

ANNOTATIONS

CONTROL RELAYS ARE SHOWN SYMBOLICALLY ON

FLOOR PLANS NEAR LIGHT FIXTURES OF THE ZONE

THE RELAY CONTROLS. RELAYS WILL BE

LOCATED/INSTALLED IN THE RELAY PANEL

DESIGNATED BY THE TOP ANNOTATION (LP-XX),

WHERE XX INDICATES THE PANEL ID.

THE BOTTOM ANNOTATION (R#) INDICATES THE

CONTROL PANEL RELAY POSITION NUMBER IN THE

INDICATED PANEL. LOCATE THE ASSOCIATED

LIGHTING FIXTURES WITH THE SAME RELAY

NUMBER FOR CIRCUITING.

ELECTRICAL BOXES AND WIRING DEVICES LIGHT CONTROLS

ELECTRICAL EQUIPMENT

ELECTRICAL EQUIPMENT FOOTPRINT.

TRANSFORMER, TRANSFER SWITCH, UPS,

SWITCHBOARD, OR OTHER. SEE FOOT PRINT FOR

EQUIPMENT ID AND CROSSREFERENCE THE

EQUIPMENT DESCRIPTION IN THE ASSOCIATED

KEYED NOTE OR EQUIPMENT SCHEDULE.

ANNOTATIONS ('X') TYP FOR ALL SWITCH TYPES

• '2' - DOUBLE POLE SWITCH

• '3' - THREE WAY SWITCH

• '4' - FOUR WAY SWITCH

• 'K' - KEYED SWITCH

• 'P' - SWITCH WITH PILOT LIGHT

• '3P' - THREE WAY SWITCH WITH PILOT LIGHT

• 'T' - TIMER SWITCH

• 'F' - FUSED SWITCH

• 'CB' - CIRCUIT BREAKER SWITCH

LIGHT FIXTURES

TELECOMMUNICATIONS

B D

D F

F S

D S

D M

S B

MECHANICAL SCHEMATIC SYMBOLS

MECHANICAL PLAN SYMBOLS

PIPING SYSTEM ABBREVIATIONS

THIS IS A MASTER LIST. ALL ITEMS MAY NOT BE APPLICABLE TO THIS PARTICULAR PROJECT

ABBREVIATIONS

A

AFCI

ATS

BHP

BTU

BTUH

C

CCT

CFM

CKT

CO

CRI

CT

DISC

DP

DP

EA

EM

ER

EX

EXR

FACP

FC

FLA

GFCI

GPM

HP

LCP

LPD

LPW

MCA

MCB

MCC

MCOP

MDP

MLO

MSS

OA

PDU

PL

PT

RA

SA

SCCR

SGR

SWBD

VA

VFD

W

AMP

ARC FAULT CIRCUIT INTERRUPTER

AUTOMATIC TRANSFER SWITCH

BRAKE HORSEPOWER

BRITISH THERMAL UNITS

BRITISH THERMAL UNITS PER HOUR

CONDUIT

COLOR CORRELATED TEMPERATURE

CUBIC FOOT PER HOUR

CIRCUIT

CLEANOUT

COLOR RENDING INDEX

CURRENT TRANSFORMER

DISCONNECT

DISTRIBUTIION PANEL (ELECTRICAL)

DIFFERNTIAL PRESSURE (MECHANICAL)

EXHAUST AIR

EMERGENCY

EXISTING TO BE REMOVED

EXISTING TO REMAIN

EXISTING TO BE RELOCATED

FIRE ALARM CONTROL PANEL

FOOTCANDLE

FULL LOAD AMPS

GROUND FAULT CIRCUIT INTERRUPTER

GALLONS PER MINUTE

HORSEPOWER

LIGHTING CONTROL PANEL

LIGHTING POWER DENSITY

LUMENS PER WATT

MINIMUM CIRCUIT AMPS

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAXIMUM CIRCUIT OVERCURRENT PROTECTION

MAIN DISTRIBUTION PANEL

MAIN LUG ONLY

MOTOR STARTER SWITCH

OUSTIDE AIR

POWER DISTRIBUTION UNIT

PILOT LIGHT

POTENTIAL TRANSFORMER

RETURN AIR

SUPPLY AIR

SHORT CIRCUIT CURRENT READING

SWITCHGEAR

SWITCHBOARD

VOLT-AMPS

VARIABLE FREQUENCY DRIVE

WATTS

12"Ø XX

P

CIRCUITING

ELECTRICAL CIRCUITING IN WALL,

UNDERFLOOR OR ABOVE CEILING

EXISTING ELECTRICAL CIRCUITING IN WALL,

UNDERFLOOR OR ABOVE CEILING

ELECTRICAL CIRCUITING FOR EMERGENCY SYSTEM

IN WALL, UNDERFLOOR OR ABOVE CEILING

ELECTRICAL CIRCUITING UNDERGROUND

ELECTRICAL CIRCUITING INDICATING NUMBER

OF HOT CONDUCTORS AND GROUND WIRES

(TYPICAL FOR ALL TYPES)

ELECTRICAL CIRCUITING "HOMERUN" TO

PANELBOARD (TYPICAL FOR ALL TYPES)

ELECTRICAL CIRCUITING IN EXPOSED CONDUIT

OR MANUFACTURED WIRING SYSTEM

G

LIGHTNING AIR TERMINAL

LIGHTNING CABLE THROUGH ROOF

LIGHTNING BIMETAL CONNECTOR

LIGHTNING BONDING POINT

LIGHTNING GROUND ROD

GROUNDING AND LIGHTNING PROTECTION

MECHANICAL, ELECTRICAL, AND PLUMBING LEGEND

H

T

S

P

CR

MD

DA

DP

ES

EL

GB

IR

KS

KP

ML

PB

RX

SD

LP

CARD READER

MOTION DETECTOR

DOOR ALARM

DOOR POSITION SWITCH

ELECTRIC DOOR STRIKE

ELECTRIC LATCH

GLASS BREAKAGE DETECTOR

INFRARED DETECTOR

KEEPER SWITCH

KEY PAD

MAGNETIC LOCK

PANIC BUTTON

REQUEST TO EXIT

SOUNDER

SECURITY CAMERA

LATCH POSITION SWITCH

SECURITY

J

J

J

NA

CB

D

ND

NM

OR

NP

NS

NE

E

Z

BLANKET WARMER

DUPLEX GROUNDING MODULE

X-RAY EMERGENCY SHUTDOWN PUSHBUTTON

X-RAY RECEPTACLE AND INDICATOR MODULE

X-RAY VIEWING SCREEN

NURSE CALL ANNUNCIATOR

CODE BLUE

DOME LIGHT

DUTY STATION

MASTER CONTROL STATION

OPERATING ROOM STATION

PATIENT STATION

STAFF EMERGENCY STATION

STAFF EMERGENCY

TOILET SHOWER STATION

ZONE LIGHT

BW

DG

XS

XR

XR

NURSE CALL

FJ

F

H

S

S

H

H

H

H

H

H

S

S

S

S

S

RTS

K

F S

D

C

B

FS

TS

DH

DH

MANUAL PULL STATION

FIRE ALARM HORN

FIRE ALARM SPEAKER

COMBINATION FIRE ALARM

SPEAKER & STROBE LIGHT

COMBINATION FIRE ALARM

HORN & STROBE LIGHT

FIRE ALARM STROBE LIGHT

HEAT DETECTOR - COMBINATION

RATE OF RISE & FIXED

HEAT DETECTOR - RATE COMPENSATION

HEAT DETECTOR - RATE OF RISE ONLY

HEAT DETECTOR - THERMAL DETECTOR

HEAT DETECTOR - FIXED TEMPERATURE

SMOKE DETECTOR - PHOTOELECTRIC

SMOKE DETECTOR - AIR SAMPLING

SMOKE DETECTOR - IONIZATION

DUCT SMOKE DETECTOR

SMOKE BEAM DETECTOR

REMOTE TEST STATION

KNOX BOX

FIRE/SMOKE DAMPER

CHIME LIGHT

ELECTRIC BELL

FLOW SWITCH

TAMPER SWITCH

DOOR HOLDER-WALL MOUNTED

DOOR HOLDER-FLOOR MOUNTED

FIRE FIGHTER JACK

R/F

R/C

R

T

P

AS

I

EOL END OF LINE RESISTOR

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR

FACP FACP

FAA FAA

IAM INDIVIDUAL ADDRESSABLE RELAY MODULE

ADDRESSABLE MONITORING MODULEMM

FIRE DETECTION AND NOTIFICATION

AIR VENT - AUTOMATIC

AIR VENT - MANUAL

AQUASTAT

BUCKET TRAP

CONCENTRIC PIPE TRANSITION

ECCENTRIC PIPE TRANSITION

EXPANSION JOINT

FLEXIBLE PIPE CONNECTION

FLOAT TRAP

FLOAT AND THERMOSTATIC TRAP

VACUUM BREAKER

FLOW BALANCE VALVE

FLOW MEASURING STATION

FLOW DIRECTION ARROW

PIPE SLEEVE

PIPE GUIDE

PIPE ANCHOR

PRESSURE GAUGE

PRESSURE/TEMPERATURE PORT

STRAINER

TEMPERATURE GAUGE

UNION

ENDCAP

MANUAL VALVE - REFER TO SPECIFICATIONS

AUTOMATIC 2-WAY CONTROL VALVE

AUTOMATIC 3-WAY CONTROL VALVE

PRESSURE REDUCING VALVE

BALL DRIP VALVE

CHECK VALVE

OUTSIDE STEM AND YOKE VALVE

SOLENOID VALVE

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/9

/2

:4 :5

P

M

C

U s e rs

\D M e sa

\D o c u m e n ts

\2

B U

IL

D

IN

G

M -0

R

E N

O V

A T

IO

N

A

D D

IT

IO

N

M E

C H d m e s a G

T H

.r v t

ISSUE FOR BID

B U

IL

D

IN

G

M -0

R

E N

O V

A T

IO

N

A

D D

IT

IO

N

J O

H N

S T

O N

IA

-1

MEP LEGEND

C A

M P

D O

D G

E

N

W

T

H A

V E

N U

E

IO

W

A A

R M

Y N

A T

IO

N

A L G

U A

R D

G-003

23067

CONTRACT: PC220020 | PROJECT:

C442N4260

2024.08.30

C O

N T

R A

C T

P

C

P

R O

J E

C T

C

N

FOTS

CLASSROOM

OFFICE

OFFICE

MECHANICAL

CLASSROOM

BREAK

AREA

CORRIDOR

JANITOR

ENTRY

MALE

LATRINE

FEMALE

LATRINE

106' - 8"

EXIT PATH 1 =

FEC

CAP

OCC

CLR

68"

CAP

OCC

CLR

68"

CAP

OCC

CLR

34"

FEC

CAP

OCC

CLR

34"

90 MIN.

90 MIN.

CODE ANALYSIS

GENERAL INFORMATION:

LOCATION OF PROJECT:

IOWA ARMY NATIONAL GUARD

CAMP DODGE, JOHNSTON, IA 50131

ARCHITECT:

MATTHEW A. COLE, AIA

BBS ARCHITECTS | ENGINEERS

219 8TH STREET, SUITE 100

DES MOINES, IA 50309

STATE OF IOWA LICENSE NO. 5829

MECHANICAL / PLUMBING ENGINEER:

HOLLY H. ELBERT, P.E.

BBS ARCHITECTS | ENGINEERS

219 8TH STREET, SUITE 100

DES MOINES, IA 50309

STATE OF IOWA LICENSE NO. 17968

ELECTRICAL ENGINEER:

ROBERT A. HEDGEPETH, P.E.

BBS ARCHITECTS | ENGINEERS

219 8TH STREET, SUITE 100

DES MOINES, IA 50309

STATE OF IOWA LICENSE NO. 14212

STRUCTURAL ENGINEER:

ERIK RAKER, P.E.

RAKER RHODES ENGINEERING

4717 GRAND AVE

DES MOINES, IA 50312

STATE OF IOWA LICENSE NO. 17922

PROJECT DESCRIPTION

The existing building is a 3,530 SF, single story building. The building is constructed of load bearing masonry walls with wood trusses and asphalt shingle roof. The existing building will be renovated to provide classrooms, offices, a small break area, and new mechanical room. Work includes an addition to the south side of the building. The addition is a 737 SF, single story addition. The addition will be constructed of load bearing masonry with wood trusses and asphalt shingle roof. The addition will include restrooms, janitor closet, and new building entry vestibule.

A geothermal well field serving the building mechanical system will be located in the northeast yard area.

APPLICABLE CODES - STATE OF IOWA

2024 International Building Code (IBC) 2024 International Mechanical Code (IMC) 2024 Uniform Plumbing Code (UPC) 2024 International Existing Building Code (IEBC) 2024 National Electrical Code, NFPA 70 2024 International Fire Code (IFC) 2012 International Energy Conservation Code (IECC) 2010 Americans with Disabilities Act

OCCUPANCY CLASSIFICATION AND USE (IBC CHAPTER 3)

B – BUSINESS

TYPES OF CONSTRUCTION (IBC CHAPTER 6)

Construction Type: V-B throughout Structural Fire Ratings (Table 601) Structural frame including columns, girders & trusses 0 hr.

Bearing exterior walls 0 hr.

Bearing interior walls 0 hr.

Nonbearing exterior walls & partitions 0 hr.

Floor construction including supporting beams & joists 0 hr.

Roof construction including supporting beams & joists 0 hr.

Fire Resistance Rating - Exterior Walls (Table 705.5) >30' = 0 hr.

BUILDING HEIGHTS AND AREAS (IBC CHAPTER 5)

Type V-B Construction, B-Occupancy (Non-Sprinkled)

Allowable Height & Stories (Table 504.3 & 504.4)

Allowable Area (Table 506.2) Existing Building Addition Total Area: B: 9,000 SF 3,530 GSF 737 GSF 4,267 GSF Height: B: 40 feet, 1 story 15 feet, 1 story 15 feet, 1 story 15 feet, 1 story

MEANS OF EGRESS (IBC CHAPTER 10)

1004 DESIGN OCCUPANT LOADS – See Table, this sheet.

1005.1 EGRESS WIDTHS – Minimum Calculated Basis

Corridors: 36" Occupant Load x 0.2" Doors: 32" Occupant Load x 0.2"

1006 COMMON PATH OF EGRESS – Shall not exceed 75 feet.

1008 MEANS OF EGRESS ILLUMINATION – Required for corridors in B occupancy.

1009 ACCESSIBLE MEANS OF EGRESS – Not required in alterations to existing buildings.

1010.1.1 – Min. clear width of 32" measured from the face of the door and the stop with the door open 90 degrees.

1010.1.2 – Doors shall swing in the direction of egress travel where serving an occupant load of 50 or more.

1013 EXIT SIGNS – Exit signs are not required in rooms that require only one exit or exit access.

1016 EXIT ACCESS – Egress from a room or space shall not pass through adjoining or intervening rooms or areas, except where such adjoining rooms or areas and the area served are accessory to one or the other, are not a Group H occupancy and provide a discernible path of egress travel to an exit.

Egress shall not pass through kitchens, storage rooms, closets or spaces used for similar purposes.

1017 EXIT ACCESS TRAVEL DISTANCE – Shall not exceed 200 feet.

1028.2 EXIT DISCHARGE – Exits shall discharge directly to exterior of building

CIVIL ENGINEER:

JUSTIN STROM, P.E.

SNYDER & ASSOCIATES

2727 SW SNYDER BOULEVARD

ANKENY, IA 50023

STATE OF IOWA LICENSE NO. P24140

FIRE, SMOKE, & LIFE SAFETY FEATURES & SYSTEMS (IBC CHAPTERS 7 & 9)

FIRE PROTECTION FEATURES

Fire Alarm: Not Required/ Not Provided FACP: Not Required/ Not Provided Remote Annunciator Panel: Not Required/ Not Provided Smoke Detection: Required/Provided Heat Detection: Not Required/ Not Provided Fire Pump: Not Required/ Not Provided Backup Power: Not Required/ Not Provided Suppression - Standpipes: Not Required/ Not Provided Suppression - Automatic: Not Required/ Not Provided Fire Extinguishers: Required/Provided: Per NFPA 10 Type I Commercial Hoods: Not Required/Not Provided

EGRESS AND RATINGS

EGRESS CALCULATION

OCC: COMBINED OCCUPANT LOAD

CAP: CAPACITY

CLR: CLEAR WIDTH

EXIT ACCESS POINTS

EXIT / EXIT DISCHARGE POINTS

CAP

OCC

CLR

30"

CAP

OCC

CLR

30"

PATH OF TRAVEL (TRAVEL DISTANCE)

1 HR RATED ASSEMBLY

2 HR RATED ASSEMBLY

3 HR RATED ASSEMBLY

4 HR RATED ASSEMBLY

1 HR RATED ASSEMBLYS

0' 8'

0' 3"

6" 1'

0' 6"

1' 2'

0' 6"

1' 2'

0' 1'

2' 4'

0' 1'

2' 4'

8' 0'

2' 4'

8'

0'

4' 8'

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

1/ 8"

'-0

1/ 4"

'-0

1/ 2"

'-0

3/ 4"

'-0

1"

'-0

A

1/

2"

'-0

30x42 9 10

1/

'-0

3"

'-0

B

C

D

E

F

G

H

87654321

9 1087654321

9/ 9/

:1

6:

P M

C :\U se rs

\M C ol e\

D oc um en ts \2

BU

IL

D

IN

G

M -0

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

AR

C

H _m co le

K4 2B

9.

rv t

ISSUE FOR BID

BU

IL

D

IN

G M

R

EN

O

VA

TI

O N

A

D D

IT

IO

N

JO

H

N

ST

O N

, I A

1-

CODE ANALYSIS

C

AM

P D

O D

G E

N W

0T

H A

VE

N

U E

IO

W

A

AR

M Y

N

AT

IO

N

AL

G

U

AR

D

G-100

23067

CONTRACT: C442N4260 | PROJ: 19082943

09.09.2026

C O

N

TR

AC

T:

C

2N

PR

O

J:

1/4" = 1'-0"A1 CODE PLAN

OCCUPANCY TABULATION PER 2024 IBC - TABLE 1004.5

R O

O M

N O

R O

O M

N A

M E

FUNCTION A

R

EA

S.

F.

P

ER

P

ER

SO

N

PE

R

SO

N

S

100 ENTRY (none) 69 SF 101 BREAK AREA Assembly - w/o Fixed Seats - Unconcentrated (tables and chairs) 47 SF 15 4 102 CORRIDOR (none) 152 SF 0 103 JANITOR Accessory Storage Areas, Mechanical Equipment Room 80 SF 300 1 104 MALE LATRINE (none) 231 SF 105 FEMALE LATRINE (none) 174 SF 106 CLASSROOM Educational - Classroom area 497 SF 20 25 107 MECHANICAL Accessory Storage Areas, Mechanical Equipment Room 251 SF 300 1 108 OFFICE Business Areas 157 SF 150 2 109 OFFICE Business Areas 343 SF 150 3 110 CLASSROOM Educational - Classroom area 1354 SF 20 68 111 FOTS Accessory Storage Areas, Mechanical Equipment Room 99 SF 300 1

N

7TH ST

9TH ST

10TH ST

11H ST

12TH ST

9TH ST

M

AIN AVE

DES M

O

INES AVE

TRUCK ENTRANCE RD

NW

BEAVER DR

NW 70TH AVE

BY

DA

TE

R

EV

IS

IO

N

M

AR

K Sc al e:

Te ch ni ci an

T- R

-S

SN

YD

ER

AS

SO

CIA

TE

S, INC

C he ck ed

B y:

En gi ne er

D at e:

1"

Pr oj ec t N o:

Sh ee t

Project No:

Sheet

S .W

. S N

YD

ER

B

LV

D

AN

KE

N

Y, IO

W A

5-

4-w w w .s ny de r-a ss oc ia te s.

co m

JF

S

TL

S

EN

G

R

-0

9-

4.

.0

C

124.0256.01

C100

C A

M P

D O

D G

E B

U

IL

D

IN

G M

-0

R

EN

O

VA

TI

O

N A

N D

A D

D

IT

IO

N

TI

TL

E

SH

EE

T

JO

H

N

ST

O N

, I O

W A

TT

-R R

W -S

S

V:

\P ro je ct s\

\1

.0

6.

\C

AD

D \S

P0 1_

6_

TI

TL

.d w g

JU

ST

IN

S

TR

O M

, T

IT

LE

S

H

EE

T, 6/

/0

4, :5

PM

, A

R C

H F

U

LL

B

LE

ED

E

(3

0.

X

2.

IN

C

H

ES

SITE PLANS

FOR

BUILDING M-04 RENOVATION AND ADDITION

CAMP DODGE

CITY OF JOHNSTON, POLK COUNTY, IOWA

VICINITY MAP

SCALE: 1" = 500'

I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.

Justin F. Strom, P.E. Date

License Number P24140 My License Renewal Date is December 31, 2026

Pages or sheets covered by this seal:

JUSTIN F.

STROM

P24140

D

PROFE

L

NS

E

IC

E

IONAL ENGINEER

AIOW

SS

OWNER/APPLICANT

CAMP DODGE

7105 NW 70TH AVE

JOHNSTON, IA 50131

ENGINEER

SNYDER AND ASSOCIATES, INC

2727 SW SNYDER BLVD

ANKENY, IA 50023

PH: (515) 964-2020

PROJECT LOCATION

SHEET LIST TABLE

Sheet Number Sheet Title

C100 TITLE SHEET

C101 PROJECT INFORMATION

C200 DEMOLITION PLAN

C300 DIMENSION PLAN

C400 GRADING AND EROSION CONTROL PLAN

C O

N

TR

AC

T:

C

2N

PR

O

JE

C T:

BY

DA

TE

R

EV

IS

IO

N

M

AR

K Sc al e:

Te ch ni ci an

T- R

-S

SN

YD

ER

AS

SO

CIA

TE

S, INC

C he ck ed

B y:

En gi ne er

D at e:

1"

Pr oj ec t N o:

Sh ee t

Project No:

Sheet

S .W

. S N

YD

ER

B

LV

D

AN

KE

N

Y, IO

W A

5-

4-w w w .s ny de r-a ss oc ia te s.

co m

JF

S

TL

S

EN

G

R

-0

9-

4.

.0

C

124.0256.01

C101

C A

M P

D O

D G

E B

U

IL

D

IN

G M

-0

R

EN

O

VA

TI

O

N A

N D

A D

D

IT

IO

N

PR

O

JE

C

T

IN

FO

R

M A

TI

O

N

JO

H N

ST

O

N , I

O

-R R

W -S

S

V:

\P ro je ct s\

\1

.0

6.

\C

AD

D \S

P0 1_

6_

TI

TL

.d w g

JU

ST

IN

S

TR

O M

, P R

O

JE

C T

IN

FO

R M

AT

IO

N , 2

6/

/0

4, :5

PM

, A

R C

H F

U

LL

B

LE

ED

E

(3

0.

X

2.

IN

C

H

ES

NOTES

1. BUILDING LINES AND CORNERS ARE FOR USE IN PREPARING CIVIL SITE

PLAN DOCUMENTS. BUILDING CORNERS AND BUILDING LINES SHOULD

BE SPECIFICALLY VERIFIED, AS NECESSARY, PRIOR TO DESIGN FOR

CONSTRUCTION OF ANY PROPOSED EXPANSION OR CONNECTION OF

BUILDING COMPONENTS.

2. FOR CLARITY PURPOSES, SURVEY SPOT ELEVATIONS ARE NOT SHOWN

ON THIS SURVEY, BUT ARE CONTAINED WITHIN THE DIGITAL CADD FILES.

3. FOR THE PURPOSE OF THIS SURVEY, STORM SEWER, SANITARY SEWER

AND WATER MAIN LINES ARE ASSUMED TO FOLLOW A STRAIGHT LINE

FROM STRUCTURE TO STRUCTURE.

4. UTILITY SERVICE LINES TO BUILDINGS ARE APPROXIMATE ONLY. AN

INTERNAL BUILDING INVESTIGATION, EXCAVATION AND/OR SUBSURFACE

LOCATING/DESIGNATING WOULD NEED TO BE PERFORMED TO

DETERMINE THE LOCATION OF SERVICES ENTERING THE BUILDING.

5. UNDERGROUND PIPE MATERIALS AND SIZES ARE BASED UPON VISIBLE

EVIDENCE VIEWED FROM ACCESS MANHOLES/STRUCTURES. DUE TO

THE CONFIGURATION AND/OR CONSTRUCTION OF THE STRUCTURE, IT

MAY BE DIFFICULT TO ACCURATELY DETERMINE THE PIPE MATERIAL

AND/OR SIZE. THE SURVEYOR WILL USE THEIR JUDGMENT AND

EXPERIENCE TO ATTEMPT TO DETERMINE, BUT COMPLETE ACCURACY

CANNOT BE GUARANTEED.

6. BOUNDARY LINES SHOWN ON THE EXISTING SITE SURVEY ARE TO

FACILITATE DESIGN OR CONCEPT NEEDS AND ENABLE CREATION OF

SAID CONSTRUCTION DOCUMENTS. THESE LINES DO NOT CONSTITUTE A

CERTIFIED BOUNDARY SURVEY AND MISSING MONUMENTS WILL NOT BE

SET.

FEATURES EXISTING PROPOSED

Spot Elevation Contour Elevation Fence (Barbed, Field, Hog) Fence (Chain Link) Fence (Wood) Fence (Silt) Tree Line Tree Stump

Deciduous Tree \\ Shrub

Coniferous Tree \\ Shrub

Communication Overhead Communication Fiber Optic Underground Electric Overhead Electric Gas Main with Size High Pressure Gas Main with Size Water Main with Size Sanitary Sewer with Size Duct Bank Test Hole Location for SUE w/ID

(*) Denotes the survey quality service level for utilities

Sanitary Manhole

Storm Sewer with Size Storm Manhole Single Storm Sewer Intake Double Storm Sewer Intake Fire Hydrant Fire Hydrant on Building Water Main Valve Water Service Valve Well Utility Pole Guy Anchor Utility Pole with Light Utility Pole with Transformer Street Light Yard Light Electric Box Electric Transformer Traffic Sign Communication Pedestal Communication Manhole Communication Handhole Fiber Optic Manhole Fiber Optic Handhole Gas Valve Gas Manhole Gas Apparatus Fence Post or Guard Post Underground Storage Tank Above Ground Storage Tank Sign Satellite Dish Mailbox Sprinkler Head Irrigation Control Valve

LEGEND

X 1225.25

X1225 1225.25

FEATURES FOUND SET

Section Corner 1/2" Rebar, Cap # 11579

(Unless Otherwise Noted) ROW Marker ROW Rail Control Point Bench Mark Platted Distance P Measured Bearing & Distance M Recorded As R Deed Distance D Calculated Distance C Minimum Protection Elevation MPE Centerline Section Line 1/4 Section Line 1/4 1/4 Section Line Easement Line

POLLUTION PREVENTION NOTES

A. POLLUTION PREVENTION AND EROSION PROTECTION

1. CODE COMPLIANCE: THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL

POTENTIAL POLLUTION AND SOIL EROSION CONTROL REQUIREMENTS OF THE IOWA

CODE, THE IOWA DEPARTMENT OF NATURAL RESOURCES (IDNR) NPDES PERMIT, THE

U.S. CLEAN WATER ACT AND ANY LOCAL ORDINANCES. THE CONTRACTOR SHALL

TAKE ALL NECESSARY STEPS TO PROTECT AGAINST EROSION AND POLLUTION FROM

THIS PROJECT SITE AND ALL OFF-SITE BORROW OR DEPOSIT AREAS DURING

PERFORMANCE OR AS A RESULT OF PERFORMANCE.

2. DAMAGE CLAIMS: THE CONTRACTOR WILL HOLD THE OWNER AND ARCHITECT /

ENGINEER HARMLESS FROM ANY AND ALL CLAIMS OF ANY TYPE WHATSOEVER

RESULTING FROM DAMAGES TO ADJOINING PUBLIC OR PRIVATE PROPERTY,

INCLUDING REASONABLE ATTORNEY FEES INCURRED TO OWNER. FURTHER, IF THE

CONTRACTOR FAILS TO TAKE NECESSARY STEPS TO PROMPTLY REMOVE EARTH

SEDIMENTATION OR DEBRIS WHICH COMES ONTO ADJOINING PUBLIC OR PRIVATE

PROPERTY, THE OWNER MAY, BUT NEED NOT, REMOVE SUCH ITEMS AND DEDUCT THE

COST THEREOF FROM AMOUNTS DUE TO THE CONTRACTOR.

B. STORM WATER DISCHARGE PERMIT

1. THIS PROJECT REQUIRES COVERAGE UNDER THE NPDES GENERAL PERMIT NO. 2

FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITIES

FROM THE IDNR, AS REQUIRED BY THE ENVIRONMENTAL PROTECTION AGENCY (EPA).

THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR

COMPLIANCE WITH AND FULFILLMENT OF ALL REQUIREMENTS OF THE NPDES

GENERAL PERMIT NO. 2 AS SPECIFIED IN THE CONTRACT DOCUMENTS.

2. ALL DOCUMENTS RELATED TO THE STORM WATER DISCHARGE PERMIT, INCLUDING,

BUT NOT LIMITED TO, THE NOTICE OF INTENT, PROOF OF PUBLICATIONS, DISCHARGE

AUTHORIZATION LETTER, CURRENT SWPPP, SITE INSPECTION LOG, AND OTHER

ITEMS, SHALL BE KEPT ON SITE AT ALL TIMES AND MUST BE PRESENTED TO ANY

JURISDICTIONAL AGENCIES UPON REQUEST. FAILURE TO COMPLY WITH THE NPDES

PERMIT REQUIREMENTS IS A VIOLATION OF THE CLEAN WATER ACT AND THE CODE

OF IOWA.

3. A "NOTICE OF DISCONTINUATION" MUST BE FILED WITH THE IDNR UPON FINAL

STABILIZATION OF THE DISTURBED SITE AND REMOVAL OF ALL TEMPORARY EROSION

CONTROL MEASURES. ALL PLANS, INSPECTION REPORTS, AND OTHER DOCUMENTS

MUST BE RETAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION.

THE CONTRACTOR SHALL RETAIN A RECORD COPY AND PROVIDE THE ORIGINAL

DOCUMENTS TO THE OWNER UPON PROJECT ACCEPTANCE AND/OR SUBMITTAL OF

THE NOTICE OF DISCONTINUATION.

C. POLLUTION PREVENTION PLAN

1. THE STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS A SEPARATE

DOCUMENT IN ADDITION TO THESE PLAN DRAWINGS. THE CONTRACTOR SHOULD

REFER TO THE SWPPP FOR ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO THE

POLLUTION PREVENTION PLAN MADE DURING CONSTRUCTION.

2. THE SWPPP ILLUSTRATES GENERAL MEASURES AND BEST MANAGEMENT PRACTICES

(BMP) FOR COMPLIANCE WITH THE PROJECT'S NPDES PERMIT COVERAGE. ALL BMP'S

AND EROSION CONTROL MEASURES REQUIRED AS A RESULT…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .