HOMESTEAD-_653_SW_4_ST-_WOOD_BUCK_.pdf

PDF 107 KB Posted

Attached to
ITQ#166008-Code Compliance and PROS Administration Building Wind Retrofit
Solicitation number
166008
Issued by
Miami-Dade County, Florida

About this file

This is a window and door buck installation layout document for the City of Homestead's Code Compliance and Parks, Recreation and Open Spaces Administration Building wind retrofit project, funded through the State of Florida Division of Emergency Management Hurricane Loss Mitigation Program. The project involves the installation of new impact windows and doors at 653 SW 4 Street in Homestead, Florida, with buck framing to be constructed from 1" x 4" blue pressure-treated borate material without window wrap. The scope includes 20 single-hung window openings with varying dimensions: items 1-4 measure 53" x 62" in masonry opening width and height, items 5-20 measure 52" x 62", and items 18-20 measure 53" x 37". All specifications were prepared by Florida Keys Windows (contact: willy@floridakeyswindows.com, 305-451-9796) and dated January 2, 2025.

The estimated cost for the buck installation totals $2,746.02, comprising material and labor costs. The calculation is based on 4,514 linear inches of perimeter framing around each opening at a cost per item of $22.57 per linear foot, with 1" x 4" borate material costing $1,805.60 and installation labor totaling $940.42 for an estimated 80 man hours. The project must comply with all Florida Division of Emergency Management requirements, the Florida Building Code, Miami-Dade County product approval standards, and applicable federal, state, and local regulations. Award will be made to the responsive and responsible vendor whose quote is most advantageous to the City, with evaluation criteria including price, contractor qualifications and licensing, experience with similar projects, ability to meet the project schedule, mobilization time, and demonstrated completion capability.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

101405 Overseas Highway, Key Largo, FL 33037

PHONE: 305-451-9796

EMAIL: willy@floridakeyswindows.com

LAYOUT FOR WINDOWS AND DOORS USING 1" X 4" BLUE PT BUCK MATERIAL WITHOUT WINDOW WRAP

Masonry Opening Height For All Doors Is Calculated From Exterior Finish Floor Height

JOB NAME: CITY OF HOMESTEAD

ADDRESS: 653 SW 4 ST

DATE: 1/2/2025

Buck Installation Costs Based On Linear Inches Of Windows/Doors Listed Below

OPENING UNIT UNIT ITEM DESCRIPTION GRID M.O. M.O.

NUMBER WIDTH HEIGHT CONFIGURATION PATTERN WIDTH HEIGHT

1 1 53 62 S/H Windows 54 1/8 63 1/8

2 2 53 62 S/H Windows 54 1/8 63 1/8

4 3 53 62 S/H Windows 54 1/8 63 1/8

5 4 53 62 S/H Windows 54 1/8 63 1/8

7 5 52 62 S/H Windows 53 1/8 63 1/8

8 6 52 62 S/H Windows 53 1/8 63 1/8

9 7 52 62 S/H Windows 53 1/8 63 1/8

11 8 52 62 S/H Windows 53 1/8 63 1/8

12 9 52 62 S/H Windows 53 1/8 63 1/8

13 10 52 62 S/H Windows 53 1/8 63 1/8

Mark

Page 1 of 2 1/2/2025

OPENING UNIT UNIT ITEM DESCRIPTION GRID M.O. M.O.

NUMBER WIDTH HEIGHT CONFIGURATION PATTERN WIDTH HEIGHT

Mark

14 11 52 62 S/H Windows 53 1/8 63 1/8

15 12 52 62 S/H Windows 53 1/8 63 1/8

16 13 52 62 S/H Windows 53 1/8 63 1/8

17 14 52 62 S/H Windows 53 1/8 63 1/8

18 15 52 62 S/H Windows 53 1/8 63 1/8

19 16 52 62 S/H Windows 53 1/8 63 1/8

20 17 52 62 S/H Windows 53 1/8 63 1/8

21 18 53 37 S/H Windows 54 1/8 38 1/8

22 19 53 37 S/H Windows 54 1/8 38 1/8

23 20 53 37 S/H Windows 54 1/8 38 1/8

1069.50 1187.50

Buck calculation for 1" x 4" borate around perimeter of every opening Cost per item Total cost

4514.00 Total linear inches around opening

22.57 Total man hours 80 1805.60

376.17 LF 1 x 4 borate 2.5 940.42

Total bid material and installation $2,746.02

Page 2 of 2 1/2/2025

File details come from the government source that posted it. Updated .