HOMESTEAD-_653_SW_4_ST-_WOOD_BUCK_.pdf
PDF 107 KB Posted
- Solicitation number
- 166008
- Issued by
- Miami-Dade County, Florida
About this file
This is a window and door buck installation layout document for the City of Homestead's Code Compliance and Parks, Recreation and Open Spaces Administration Building wind retrofit project, funded through the State of Florida Division of Emergency Management Hurricane Loss Mitigation Program. The project involves the installation of new impact windows and doors at 653 SW 4 Street in Homestead, Florida, with buck framing to be constructed from 1" x 4" blue pressure-treated borate material without window wrap. The scope includes 20 single-hung window openings with varying dimensions: items 1-4 measure 53" x 62" in masonry opening width and height, items 5-20 measure 52" x 62", and items 18-20 measure 53" x 37". All specifications were prepared by Florida Keys Windows (contact: willy@floridakeyswindows.com, 305-451-9796) and dated January 2, 2025.
The estimated cost for the buck installation totals $2,746.02, comprising material and labor costs. The calculation is based on 4,514 linear inches of perimeter framing around each opening at a cost per item of $22.57 per linear foot, with 1" x 4" borate material costing $1,805.60 and installation labor totaling $940.42 for an estimated 80 man hours. The project must comply with all Florida Division of Emergency Management requirements, the Florida Building Code, Miami-Dade County product approval standards, and applicable federal, state, and local regulations. Award will be made to the responsive and responsible vendor whose quote is most advantageous to the City, with evaluation criteria including price, contractor qualifications and licensing, experience with similar projects, ability to meet the project schedule, mobilization time, and demonstrated completion capability.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
101405 Overseas Highway, Key Largo, FL 33037
PHONE: 305-451-9796
EMAIL: willy@floridakeyswindows.com
LAYOUT FOR WINDOWS AND DOORS USING 1" X 4" BLUE PT BUCK MATERIAL WITHOUT WINDOW WRAP
Masonry Opening Height For All Doors Is Calculated From Exterior Finish Floor Height
JOB NAME: CITY OF HOMESTEAD
ADDRESS: 653 SW 4 ST
DATE: 1/2/2025
Buck Installation Costs Based On Linear Inches Of Windows/Doors Listed Below
OPENING UNIT UNIT ITEM DESCRIPTION GRID M.O. M.O.
NUMBER WIDTH HEIGHT CONFIGURATION PATTERN WIDTH HEIGHT
1 1 53 62 S/H Windows 54 1/8 63 1/8
2 2 53 62 S/H Windows 54 1/8 63 1/8
4 3 53 62 S/H Windows 54 1/8 63 1/8
5 4 53 62 S/H Windows 54 1/8 63 1/8
7 5 52 62 S/H Windows 53 1/8 63 1/8
8 6 52 62 S/H Windows 53 1/8 63 1/8
9 7 52 62 S/H Windows 53 1/8 63 1/8
11 8 52 62 S/H Windows 53 1/8 63 1/8
12 9 52 62 S/H Windows 53 1/8 63 1/8
13 10 52 62 S/H Windows 53 1/8 63 1/8
Mark
Page 1 of 2 1/2/2025
OPENING UNIT UNIT ITEM DESCRIPTION GRID M.O. M.O.
NUMBER WIDTH HEIGHT CONFIGURATION PATTERN WIDTH HEIGHT
Mark
14 11 52 62 S/H Windows 53 1/8 63 1/8
15 12 52 62 S/H Windows 53 1/8 63 1/8
16 13 52 62 S/H Windows 53 1/8 63 1/8
17 14 52 62 S/H Windows 53 1/8 63 1/8
18 15 52 62 S/H Windows 53 1/8 63 1/8
19 16 52 62 S/H Windows 53 1/8 63 1/8
20 17 52 62 S/H Windows 53 1/8 63 1/8
21 18 53 37 S/H Windows 54 1/8 38 1/8
22 19 53 37 S/H Windows 54 1/8 38 1/8
23 20 53 37 S/H Windows 54 1/8 38 1/8
1069.50 1187.50
Buck calculation for 1" x 4" borate around perimeter of every opening Cost per item Total cost
4514.00 Total linear inches around opening
22.57 Total man hours 80 1805.60
376.17 LF 1 x 4 borate 2.5 940.42
Total bid material and installation $2,746.02
Page 2 of 2 1/2/2025
File details come from the government source that posted it. Updated .