Questions and Answers Version 3 Dated 12 April 2016
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ_Attach_5._FAR-DFARS_Provisions_and_Clauses_Revision_1.docx | DOCX document | |
| RFQ_Attach_1._PWS_Revision_1.pdf | ||
| Q A_HC1021-16-T-0001_-_Version_02.docx | DOCX document | |
| Q A_HC1021-16-T-0001_-_Version_01.docx | DOCX document | |
| Q A_HC1021-16-T-0001.docx | DOCX document | |
| RFQ_Attach_2_QASP.pdf | ||
| RFQ_HC1021-16-T-0001.pdf | ||
| RFQ_Attach_1._PWS.pdf | ||
| RFQ_Attach_3._Price_Quotation_Spreadsheet.xls | XLS spreadsheet | |
| RFQ_Attach_5._FAR-DFARS_Provisions_and_Clauses.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HC1021-16-T-0001
DISA Europe Furniture Questions and Answers As of 12 Apr 16
| Question # |
| Question |
| PWS Reference |
| Government Answer |
| 1 |
| Can an international company bid on this project? |
| N/A |
| Yes |
| 2 |
| How long will take to award the resulting contract for RFQ HC1021-16-T-0001 |
| N/A |
| We cannot provide a contract award date as the contract award is dependent on the receipt and approval of quotes IAW LPAT. |
| 3 |
| Are Offerors allowed to offer work stations that improve what has been specified on RFQ number HC1021-16-T-0001. |
| 6.1.3.1 thru 6.1.3.12 |
| All workstations must meet the specifications identified in the PWS. |
| 4 |
| After contract award, what is the start date for the installation? |
| 6.3 |
| The furniture installation will begin no later than 6 June 2016. The contractor has no more than five (5) business days to install delivered furniture. |
| 5 |
| On the bid you have an USA certification for the work stations (US CertificationBIFMA). Is the use of European standards allowed? |
| 6.1.3.6 |
| Yes. As long as the equivalent European standard meets the International Organization for Standardization (ISO)/TC 136 Furniture. |
| 6 |
| Who do we contact for the site visit? |
| 6.1.1 Subtask 1 |
| Please reach out to the Primary Contracting Officer’s Representative (COR) Megan Von Bokel. She can be contacted via email at Megan.a.vonbokel.civ@mail.mil. |
| 7 |
| There was a similar project /bid request for this same building in summer 2015. Is this the same project or updated. If this is a new project, are you planning to "match existing" from the 2015 project? |
| N/A |
| No, this is not the same project so we are not looking to "match existing" as this is an entirely new effort. |
| 8 |
| Can you provide more detail on dimensions and description on the items in 6.1.3.1 ( f) - that must be supported at each station: |
a. (1) clear tube
b. (2) KVM switches
c. (2) thin clients
d. (2) desktops - are these in addition to the CPUs listed under
6.1.3.1 (d) or are these the units to be stored on the CPU shelves?
| 6.1.3.1 (f) and 6.1.3.1 (d) |
| The approximate dimensions are as follows: |
a. (1) clear tube: 1.5"Hx8"Wx6"D
b. (2) KVM switches: 2"Hx11.25"Wx12"D
c. (2) thin clients: 8.2"Hx1.25"Wx9"D
d. No, desktops will be placed in CPU shelves
| 9 |
| What is the quantity of above surface punch-outs required at each station? |
| 6.1.3.4 (q) |
| Each workstation shall have two (2) punch outs located at the bottom of each workstation that can accommodate routing of data connections coming from cable system under the floor. One (1) punch out in located at the bottom of each workstation to accommodate electrical/power connections. . Four (4) punch outs located at the top of each workstation .Attachment 2 includes the conceptual design of where the cables will enter the furniture. |
| 10 |
| Is a hardwired power solution required or would horizontal or vertical power strips with locking plugs that connect to locking receptacles beneath the floor be an acceptable solution? |
| 6.1.3.4 |
| The vendor would have to provide the locking receptacles. Only junction boxes that require a hardwire power solution will be located under the floor. |
| 11 |
| Is there another drawing available of the cabling diagram? Is there an AutoCAD dwg. file available of the room? |
| N/A |
| No, there are no other diagrams available. |
| 12 |
| Can there be a dumpster on site for trash removal? |
| N/A |
| No, vendor is responsible for removing all trash. |
| 13 |
| 6.1.3.1 (f) states: “capability to support (4) 24” monitors (plus additional equipment), and 6.1.3.1 states “(4) single monitor arms for each workbench”. (4) 24” monitors (approximately 80” of monitor width), even in a parabolic configuration, will not on a 60” wide work surface. Is a dual “over/under monitor” configuration acceptable? |
| 6.1.3.1 |
| Yes, a dual over/under configuration is acceptable. If over/under means two directly on top of the other. The monitor arms must support a possible reconfiguration at a later date. The PWS states a minimum 60"W and maximum 63"W |
| 14 |
| Are we allowed to offer work stations that improve what has been specified on contract number HC1021-16-T-0001? Specifically, can we use MaxCompact phenolic compact laminate boards with a thickness of 18 mm with anti-scratch system, high shock resistance? |
| 6.1.3.12 |
| All laminate that is equal to or greater than the requirements stated in PWS paragraph 6.1.3.12 are considered acceptable. |
| 15 |
| 6.1.3.1 (a) states: the “maximum bench dimensions may not exceed 63”W x 33”D x 33”H”. The 33” overall height prohibits the inclusion of a slat wall above the work surface to mount the monitor arms/ monitors on to them. Is the intent to have the monitors on work surface based monitor arrays vs. slat wall? |
| 6.1.3.1 (a) |
| 33"H is without the monitor arms/wall. Both the surface based monitor arrays and slat wall are acceptable. |
| 16 | |
| Regarding the task chair, it calls for the chair height to be 36-48”H. Can you please confirm if this is the overall height of the chair required, or if it is the seat height? A 36”H height of a chair would be a stool requirement. | |
| 6.1.3.2(a) | |
| Per the PWS the minimum dimensions are 29”D x27”W x36”– 48”H. These dimensions are for the overall height of the chair. |
| 17 |
| Could it be possible to unify all the cabling punch outs on the working surface on a central zone? |
| 6.1.3.4 (q) |
| No, a cable separation is required; therefore we are requesting two punch outs to accommodate the routing of data connections from the cable system under the floor. |
| 18 |
| We need the attachment 2 document in a legible format in order to understand its content. |
| Attachment 2 |
| 19 |
| Console sizes. We are looking at each work space being 72” wide, whereas your maximum requirement is detailed as 63” wide. We could meet the maximum width requirement; however, this will make 4 x 24” monitors over hang each work position. |
| 6.1.3.1 |
| No the maximum requirement is 63"W. |
| 20 |
| Please clarify what Clear Cube is, along with physical dimensions. KVM switches, please confirm that you would like these put onto shelves inside the console, and please clarify what thin clients are, along with the physical dimensions and also where you would like them located inside or on top of the consoles. |
| 6.1.3.1(f) |
| The monitors, clear cube, KVM switches, thin clients, keyboards, mouse, and phones are projected to be placed on the top of the work surface/consoles. The desktops are projected to be stored on the CPU shelves. Please see published answer (#8) for clear cube, KVM switches, and thin client dimensions. |
| 21 |
| Please confirm that operators will be viewing a media wall |
| Attachment 1 |
| Yes, the operators will be viewing a media wall. The monitors are reflected in Attachment 1 - Conceptual Layout. |
| 22 |
| Delivery access – as per the attached conceptual layout drawing, would the main access be through these doors, located on the left hand side. If so, please clarify the height of the concrete base outside, as we need to look at the possibilities of unloading straight from the truck with a tailgate. |
| N/A |
| Yes, they would be through the doors located on the left hand side. The concrete base height is approximately 20". |
image2.emf
DS_ClientCube_2.pdf
ClientCube 2 Line of sight separation from the datacenter to the desk!
NSA/NIAP certified KVM Zero Client enclosure.
DATASHEET
The First All-In-One Secure Cross-Domain Level PCoIP Solution
Following in the tradition of purpose-built solutions for Federal and DoD customers, ClearCube’s ClientCube 2 is the first endpoint that consolidates multiple networks
(tactical, secret, confidential, unclassified) into one device at the desktop, while main-taining physical network separation to centralized computing resources in the datacen-ter. VMware Horizon View and PCoIP Blade PC workstations can now be isolated and secured in the datacenter without compromising the user experience or network securi-ty at the desktop. This sleek all-in-one unit integrates ClearCube’s secure stateless zero client devices with Belkin’s NIAP-approved secure KVM (keyboard-video-mouse) switch to create a multi-network workstation like no other.
Integrated Secure KVM
The integrated, Secure KVM features true data path isolation for superior security and data protection for government agencies. One of the most utilized preventive measures for thwarting attacks, KVM switching devices can be used to securely connect peripheral devices, including audio equipment and large high-resolution displays, and to switch quickly among multiple computers and networks with a single keyboard, monitor, mouse, and smart card reader. It is fully compatible with legacy and new government systems and is listed and approved to the latest KVM testing standard (EAL 2, Protection
Profile v2.1). The KVM switch is specially designed to prevent peripherals from leaking information and to remain tamper-free upon delivery. ClientCube 2 helps agencies save time, money, and resources by future-proofing their workstation security investments.
Minimized Space Consumption
Desktop real estate is at a premium, and ClientCube 2 optimizes every inch of consump-tion. Low profile zero clients (fiber, copper or both) are tightly coupled with the Secure
KVM switch to eliminate excess cable lengths, wasted power connections, and sloppi-ness that looks unprofessional.
Market Leading Innovations
The Secure KVM included with ClientCube 2 features unidirectional data flow that prevents upstream USB intrusion; high-retention force USB connectors to eliminate unexpected cable disconnections; illuminated and color-coded port indicators; and com-mon access card (CAC) port locking that maintains user login to selected host networks.
ClientCube 2 Benefits
Delivers full quality computing experience via a LAN connection to
VMware Horizon View desktop or
PCoIP Blade PC workstation
Optimized for cross-domain environments; this solution saves space, power, and is fully integrated
Extend tightly controlled security profiles from the datacenter to remote desktops
Tested and approved to NIAP EAL 2, Protection Profile v2.1
ClientCube provides line of sight isolation from datacenter to the desktop
Increases security of physical and data assets
© 2013 ClearCube Technology, Inc. | 3700 W Parmer Lane, Austin, TX 78727 | Voice: 512.652.3500 Fax: 512.652.3501 Toll Free: 866.652.3500 | www.clearcube.com sales@clearcube.com 1
DS_ClientCube_2_20130417_Rev D.pub
Configuration Flexibility
ClientCube 2 is factory integrated at ClearCube’s secured facility. Options include from 2, 3 or 4 ClearCube zero client devices
(including ClearCube’s full range of zero client products featuring fiber, copper, CAC, and other innovations) that are KVM switched including audio, to 1 or 2 high resolution displays, allowing multiple classified and unclassified routes to terminate at a single set of peripherals at the warfighter operator’s desk. For the security officers, ClientCube 2 provides line of sight isolation from the data-center to the desktop.
Sample Configurations
All highly classified SIPR/NIPR NIPR/Unclassed
4 fiber zero clients switching 2 displays, keyboard, mouse, sound
1 fiber + 1 copper zero client switching 2 displays, keyboard, mouse, sound
2 copper zero clients switching 1 display, keyboard, mouse, sound
Cross-Domain Solution
2 © 2012 ClearCube Technology, Inc. | 3700 W Parmer Lane, Austin, TX 78727 | Voice: 512.652.3500 Fax: 512.652.3501 Toll Free: 866.652.3500 | www.clearcube.com sales@clearcube.com
DS_ClientCube_2_20130417_Rev D.pub
Specifications
Dimensions Four Clients: 6 inches (w) x 14 inches (h) x 10 inches (d)
Operating System None
Video Supports up to 2 monitors at 32 bit color depth and up to 2560 x 1600 @ 75 Hz per zero client device.
Power Supply Universal 100-240 VAC, 50-60Hz, Output: 12 V DC, 12.5A
Shipping Weight Fully configured, 25 lbs.
Environment Stationary office, home office installation, 0° to 35° C
ClientCube 2 Hardware Specifications
Ordering Information
Part Number Description
G0900176 4 port kvm 4 client enclosure, two displays per client
Use the following part numbers to order your ClientCube 2:
ClientCube 2 Rear View
ClientCube Configuration provides
Total Situational Awareness
Dual monitor Zero Clients have one
DVI output connected to the SKVM and the other to a persistent monitor.
The Blade PC or VDI VM connected to the Zero Client are configured to clone the primary display to the secondary output.
Video from all networks is always visible
One network is active at a time
Physical separation intact image1.emf