G.003_RCP Environmental Limited Pre-Renovation Flooring Survey.pdf
PDF 2 MB Posted
- Attached to
- WFLHD Facility 2nd Floor Remodel Federal contract opportunity
- Solicitation number
- 69056721Q000009
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Q-and-A_2021-01-25.pdf | ||
| Q-and-A_2021-01-19.pdf | ||
| 69056721Q000009_A0002.pdf | ||
| 69056721Q000009_A0001.pdf | ||
| Q-and-A_2021-01-08.pdf | ||
| Q-and-A_2021-01-06.pdf | ||
| Q-and-A_2021-01-04.pdf | ||
| 69056721Q000009.pdf | ||
| G.001_WFLHD 2nd Floor Room Dimensions Drawing.pdf | ||
| G.002_WFLHD 2nd Floor Cubicle Layout Drawing.pdf | ||
| G.004_Past Performance Reference Questionnaire.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Residential Commercial Public
August 11, 2020
TO Lynn Brundage U.S. Department of Transportation Federal Highway Administration 610 East Fifth Street Vancouver, Washington 98661
Lynn.Brundage@dot.gov Phone: 360-619-7768
FROM Dave Routtu RCP Environmental, LLC 9901 NE 7th Ave., Suite B-223E Vancouver, WA 98685 dave.routtu@rcpenvironmental.com Phone: 360-787-3682
RE Limited Pre-Renovation Flooring Survey Report Second Floor Northeast Area 610 East 5th Street, Vancouver, Washington
Introduction
RCP Environmental was retained by the U.S Department of Transportation Federal Highway Administration to provide limited asbestos sampling survey services at the Western Federal Lands Building in the Northeast Area of the Second Floor located at 610 East Fifth Street in Vancouver, Washington. The purpose of this inspection is to locate, identify and quantify asbestos-containing flooring materials in the Northeast Area of the Second Floor prior to limited renovation. This survey is intended to fulfill the U.S. Environmental Protection Agency (EPA), Southwest Clean Air Authority (SCAA) and Washington Department of Labor and Industries (L&I) requirements for identification of hazardous building materials prior to renovation or demolition
Site Description
The property subject to this investigation is an approximate 14,000 square foot two story office building constructed circa 1930. The building appears to be brick construction on a concrete slab foundation. Roofing is not included in the scope of this survey. Interior finishes appear to be gypsum wallboard walls with laid-in suspended ceiling panels. Floor coverings in Northeast Area of the Second Floor are a mix of carpet, and floor tile over a concrete floor.
The entire area is covered with glued-down carpet. Two types of floor tile were discovered underneath the carpet. Approximately 1,300 square feet of gray 12x12 floor tile with black mastic and approximately 3,900 square feet of tan 9x9 floor tile with black mastic.
Scope of Work
This survey included asbestos sampling. This inspection is limited to carpet-covered flooring materials in the Northeast Area of the Second Floor. The purpose of this survey is to provide an inventory of asbestos-containing flooring materials (ACM) prior to renovation activities
G.003 - RCP Environmental Limited Pre-Renovation Flooring Survey Report mailto:Lynn.Brundage@dot.gov tel:503.467.4153 mailto:dave.routtu@rcpenvironmental.com
U.S. Department of Transportation Federal Highway Administration
Western Federal Lands Limited Asbestos Survey Report
The visual inspection and sampling were performed by AHERA-Accredited Inspector Dave Routtu (Asbestos Building Inspector Certificate Number IMR-20-5871A) of RCP Environmental on Thursday, August 6, 2020.
This report provides the results of the survey, and sampling and assessments.
Methodology
Asbestos Survey Suspect materials identified during the onsite survey were grouped and classified as homogeneous materials based on their appearance, usage, and age of the building. Representative samples of accessible homogeneous flooring materials were sampled from the Northeast Area of the Second Floor. Materials determined by the inspector to be non-suspect, such as wood, metal, glass, and fiberglass insulation, were not sampled. Additional suspect building materials may be present in areas that were inaccessible, unsafe to inspect, or obscured from view during the inspection process.
Samples were collected in such a manner as to minimize release of the material into the surroundings. Material type, sample number, sample location and other pertinent information were recorded at the time of sampling.
Each sample was placed in a sample container labeled with a unique sample number and submitted under Chain-of-Custody documentation to QuanTem Laboratories, a National Voluntary Laboratory Accreditation Program (“NVLAP”) accredited laboratory for analysis. Samples were analyzed in accordance with EPA Method 600/R-93-116, using Polarized Light Microscopy (“PLM”) with dispersion staining and using visual area estimation to determine percent asbestos content. This method allows for the identification of the primary types of asbestos used in building materials. The lower limit of detection for this method is one percent.
Samples containing less than one percent asbestos by PLM with visual area estimation are reported as Trace.
Findings
Asbestos Asbestos was detected in all ten of the samples collected during this survey.
Summary of Analytical Results
Asbestos
SAMPLE
NUMBER
MATERIAL DESCRIPTION LOCATION ASBESTOS
CONTENT AND
TYPE
CONDITION /
FRIABILITY
APPROXIMATE
QUANTITY
039 Tan 9x9 Floor Tile and Black Mastic
NW Room 239 Under Carpet
7% Chrysotile (Tile) 10% Chrysotile (Mastic)
Good / NF 3,900 Sq. Ft.
040 Tan 9x9 Floor Tile and Black Mastic
NE Room 239 Under Carpet
7% Chrysotile (Tile) 10% Chrysotile (Mastic)
Good / NF Same as Sample
041 Tan 9x9 Floor Tile and Black Mastic
SW Room 239 Under Carpet
7% Chrysotile (Tile) 10% Chrysotile (Mastic)
Good / NF Same as Sample
042 Tan 9x9 Floor Tile and Black Mastic
SE Room 235 Under Carpet
7% Chrysotile (Tile) 10% Chrysotile (Mastic)
Good / NF Same as Sample
043 Tan 9x9 Floor Tile and Black Mastic
West Room 235 Under Carpet
7% Chrysotile (Tile) 10% Chrysotile (Mastic)
Good / NF Same as Sample
044 Gray 12x12 Floor Tile and Black Mastic
East Room 238 Under Carpet
5% Chrysotile (Tile) 3% Chrysotile (Mastic)
Good / NF 1,300 Sq. Ft.
045 Gray 12x12 Floor Tile and Black Mastic
East Room 238 Under Carpet
5% Chrysotile (Tile) 3% Chrysotile (Mastic)
Good / NF Same as Sample
046 Gray 12x12 Floor Tile and Black Mastic
SW Room 235 Under Carpet
5% Chrysotile (Tile) 3% Chrysotile (Mastic)
Good / NF Same as Sample
047 Gray 12x12 Floor Tile and Black Mastic
West Room 235 Under Carpet
5% Chrysotile (Tile) 3% Chrysotile (Mastic)
Good / NF Same as Sample
048 Tan 9x9 Floor Tile and Black Mastic
Room 234 5% Chrysotile (Tile) 7% Chrysotile (Mastic)
Good / NF Same as Sample
ND = No Asbestos Detected F = Friable NF = Nonfriable
Regulatory Information
Asbestos Regulatory Issues Washington Department of Labor and Industries (L&I), and Southwest Clean Air Authority (SWCAA) define asbestos-containing materials (ACM) as those which contain greater than 1% asbestos by weight
Recommendations
Asbestos Asbestos containing materials must be removed by a Washington L&I licensed full scale asbestos abatement contractor utilizing L&I certified asbestos workers under the direct supervision of an L&I certified asbestos supervisor prior to any renovation activities that could disturb the materials.
Limitations
This survey is intended to be a limited pre-renovation asbestos survey. This survey is not to be used as an abatement project design document. If additional suspect ACM is subsequently discovered during renovation or demolition, either stop work and have the suspect material tested, or presume it is asbestos and have it removed by a licensed asbestos abatement contractor.
The information contained in this report is based on information furnished by the client and observations and test results provided by RCP Environmental. These observations are time dependent, are subject to changing site conditions, and revisions to Federal, state, and local regulations. RCP warrants that these findings have been promulgated after being prepared in accordance with generally accepted practices in the asbestos testing and abatement industry. No other warranties are implied or expressed.
Respectfully, RCP Environmental
Dave Routtu Senior Project Manager
Attachment A: Laboratory Analysis Report and Associated Chain of Custody Documentation Attachment B: Sample Locations Diagram Attachment C: Inspector Certification
Date Received: 08/07/2020
Project: USDOT Fed Hwy Department
QuanTEM Lab No. 325496
Analyzed By: Jane McHose
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: 610 E. 5th Street, Vancouver, WA
Project Number: 20-0034
Account Number: C132
Received By: Elena LaFarge
Date Analyzed: 08/11/2020
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: RCP Environmental, LLC
13828 NW 10th Ct, Unit B
Vancouver, WA 98685
Non Fibrous
001 39 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
001a Layered Vinyl
CaCO37Chrysotile
Asbestos Present NA
Floor Tile
Tan
001b Layered Tar
CaCO310Chrysotile
Asbestos Present NA
Mastic
Black
002 40 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
002a Layered Vinyl
CaCO37Chrysotile
Asbestos Present NA
Floor Tile
Tan
002b Layered Tar
CaCO310Chrysotile
Asbestos Present NA
Mastic
Black
003 41 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM Lab No. 325496
Analyzed By: Jane McHose
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: 610 E. 5th Street, Vancouver, WA
Project Number: 20-0034
Account Number: C132
Received By: Elena LaFarge
Date Analyzed: 08/11/2020
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: RCP Environmental, LLC
13828 NW 10th Ct, Unit B
Vancouver, WA 98685
Non Fibrous
003a Layered Vinyl
CaCO37Chrysotile
Asbestos Present NA
Floor Tile
Tan
003b Layered Tar
CaCO310Chrysotile
Asbestos Present NA
Mastic
Black
004 42 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
004a Layered Vinyl
CaCO37Chrysotile
Asbestos Present NA
Floor Tile
Tan
004b Layered Tar
CaCO310Chrysotile
Asbestos Present NA
Mastic
Black
005 43 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
QuanTEM Lab No. 325496
Analyzed By: Jane McHose
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: 610 E. 5th Street, Vancouver, WA
Project Number: 20-0034
Account Number: C132
Received By: Elena LaFarge
Date Analyzed: 08/11/2020
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: RCP Environmental, LLC
13828 NW 10th Ct, Unit B
Vancouver, WA 98685
Non Fibrous
005a Layered Vinyl
CaCO37Chrysotile
Asbestos Present NA
Floor Tile
Tan
005b Layered Tar
CaCO310Chrysotile
Asbestos Present NA
Mastic
Black
006 44 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
006a Layered Vinyl
CaCO33Chrysotile
Asbestos Present NA
Floor Tile
Gray
006b Layered Tar
CaCO35Chrysotile
Asbestos Present NA
Mastic
Black
007 45 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
007a Layered Vinyl
CaCO33Chrysotile
Asbestos Present NA
Floor Tile
Gray
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
QuanTEM Lab No. 325496
Analyzed By: Jane McHose
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: 610 E. 5th Street, Vancouver, WA
Project Number: 20-0034
Account Number: C132
Received By: Elena LaFarge
Date Analyzed: 08/11/2020
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: RCP Environmental, LLC
13828 NW 10th Ct, Unit B
Vancouver, WA 98685
Non Fibrous
007b Layered Tar
CaCO35Chrysotile
Asbestos Present NA
Mastic
Black
008 46 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
008a Layered Vinyl
CaCO33Chrysotile
Asbestos Present NA
Floor Tile
Gray
008b Layered Tar
CaCO35Chrysotile
Asbestos Present NA
Mastic
Black
009 47 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
009a Layered Vinyl
CaCO33Chrysotile
Asbestos Present NA
Floor Tile
Gray
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
QuanTEM Lab No. 325496
Analyzed By: Jane McHose
Methodology: EPA/600/R-93/116
Polarized Light Microscopy Asbestos Analysis Report
Project Location: 610 E. 5th Street, Vancouver, WA
Project Number: 20-0034
Account Number: C132
Received By: Elena LaFarge
Date Analyzed: 08/11/2020
QuanTEM
Sample ID
Client
Sample ID Composition
Color /
Description Asbestos (%)
Non-Asbestos
Fiber (%)
Client: RCP Environmental, LLC
13828 NW 10th Ct, Unit B
Vancouver, WA 98685
Non Fibrous
009b Layered Tar
CaCO35Chrysotile
Asbestos Present NA
Mastic
Black
010 48 Layered Glue
CaCO3
Asbestos Not Present NA
Carpet Mastic
Yellow
010a Layered Vinyl
CaCO35Chrysotile
Asbestos Present NA
Floor Tile
Gray
010b Layered Tar
CaCO37Chrysotile
Asbestos Present NA
Mastic
Black
Date of Report
8/11/2020
Jane McHose, Laboratory Analyst
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
FIRST FLOOR PLAN
SECOND FLOOR PLAN
MECHANICAL INSULATION
SURFACING MATERIAL
MISCELLANEOUS MATERIAL
MATERIAL SYMBOL
DRAWING REFERENCE TO BULK SAMPLE FIELD CODE,
SEE INVENTORY OF SAMPLES
<1% NEGATIVE - POSITIVE +
Electrical
Room
Phone
Room
Genise
Dance
Dale
Lewis
ELEVATOR
NOTE: ALL OLD LCT TO BE REMOVED
BOILER
DEBRIS
1-18A
1-20A
1-19A
1-21A
1-26A
1-27A
GYP
1-30L
1-31A
1-29A
1-32A
1-24A1-25A 1-23A
1-22A
1-33A 1-34A
009 008
1-28A
PIPE/DUCT
1-16A
1-17A
1-4A
1-5A
1-7A
1-6A
1-8A
1-10A 1-11A
WALL PANEL
1-15A
1-14A
1-13A
2-7A
2-12A
2-11B
2-11A
2-8A
2-9A
2-10A
2-4A
2-3A 2-5A
2-1A
77053.000-001
77053.000-002
77053.000-003
77053.000-004
77053.000-005
77053.000-006
77053.000-007
77053.000-008
77053.000-009
77053.000-010
77053.000-011
77053.000-012
77053.000-013
77053.000-014
77053.000-015
77053.000-016
77053.000-017
77053.000-018
77053.000-019
77053.000-020
77053.000-021
77053.000-022
77053.000-023
77053.000-024
77053.000-025
77053.000-026
77053.000-027
77053.000-028
77053.000-029
77053.000-030
77053.000-031
77053.000-032
77053.000-033
77053.000-034
77053.000-035
LAY-IN CEILING TILE
HARD FITTINGS/PIPE INSULATION
MORTAR
GYPSUM WALLBOARD/JOINT COMPD.
COVEBASE/MASTIC
VINYL FLOOR TILE/MASTIC
LAY-IN CEILING TILE
AIR CELL PIPE INSULATION
MORTAR
MATERIAL DEBRIS
LAY-IN CEILING TILE
MATERIAL DEBRIS
AIR CELL PIPE INSULATION
SHEET FLOOR COVERING
MASTIC
GYPSUM AND PLASTER
MATERIAL DEBRIS
GYPSUM WALLBOARD/JOINT COMPD.
GLUED-ON CEILING TILES
LAY-IN CEILING TILE
WALL AND CEILING PLASTER
WALL AND CEILING PLASTER
VINYL FLOOR TILE/MASTIC
WALL AND CEILING PLASTER
GLUED-ON CEILING TILES
SPRAYED FIBROUS FIREPROOFING
HARD FITTINGS/PIPE INSULATION
HARD FITTINGS/PIPE INSULATION
HARD FITTINGS/PIPE INSULATION
CAULK (ROOF AREA)
HARD FITTINGS/PIPE INSULATION (ROOF AREA)
THERMAL INSULATION (ROOF AREA)
MORTAR (ROOF AREA)
MASTIC (ROOF AREA)
MASTIC (ROOF AREA)
DRAWING
REFERENCE
FIELD
CODE
LAB
RESULT
MATERIAL
SAMPLED
(COLLECTED BY PBS)
INVENTORY OF ASBESTOS SAMPLES
ASBESTOS SAMPLE SYMBOLS
1-4A
1-5A
1-6A
1-7A
1-8A
1-9A
1-10A
1-11A
1-13A
1-14A
1-15A
77053.000-1-4A
77053.000-1-5A
77053.000-1-6A
77053.000-1-7A
77053.000-1-8A
77053.000-1-9A
77053.000-1-10A
77053.000-1-11A
77053.000-1-13A
77053.000-1-14A
77053.000-1-15A
TSI
TSI
TSI
INSULATION
JOINT COMPOUND
TSI
CEILING TILE
CEILING TILE
CEILING TILE
PLASTER
CEILING TILE
DRAWING
REFERENCE
FIELD
CODE
LAB
RESULT
MATERIAL
SAMPLED
(COLLECTED BY OTHERS)
INVENTORY OF ASBESTOS SAMPLES
1-16A 77053.000-1-16A (+) TSI (PIPE LAGGING)
1-17A 77053.000-1-17A (+) TSI FITTING
1-18A 77053.000-1-18A (-) TSI FITTING
1-19A 77053.000-1-19A (+) TSI PIPE INSULATION
1-20A 77053.000-1-20A (-) TSI HARD FITTING
1-21A 77053.000-1-21A (-) CEILING TILE
1-22A 77053.000-1-22A (-) PLASTER
1-23A 77053.000-1-23A (+) TSI
1-24A 77053.000-1-24A (-) CEILING TILE
1-25A 77053.000-1-25A (+) TSI
1-26A 77053.000-1-26A (-) TEXTURE
1-27A 77053.000-1-27A (-) WALLBOAD
1-28A 77053.000-1-28A (+) TSI
1-29A 77053.000-1-29A (-) PLASTER
1-31A 77053.000-1-31A (-) PLASTER, LATHBOAD DUST
1-32A 77053.000-1-32A (+) TSI
1-33A 77053.000-1-33A (-) TSI CEMENT
1-34A 77053.000-1-34A (+) BOILER GASKET CASING
2-1A 77053.000-2-1A (-) CEILING
2-3A 77053.000-2-3A (-) PLASTER
2-4A 77053.000-2-4A (-) PLASTER
2-5A 77053.000-2-5A (-) CEILING TILE
2-6A
2-6A 77053.000-2-6A (-) CEILING TILE
2-7A 77053.000-2-7A (-) CEILING ADHESIVE
2-8A 77053.000-2-8A (+) CEILING TEXURE
2-9A 77053.000-2-9A (+) SHEETROCK
2-10A 77053.000-2-10A (-) PLASTER
2-11A 77053.000-2-11A (+) FLOOR TILE
2-11B 77053.000-2-11B FLOOR TILE MASTIC
GENERAL NOTES ASBESTOS NOTES
1. THIS DRAWING IS DIAGRAMMATIC. IT IS FOR GENERAL INFORMATION AND SAMPLE
LOCATIONS.
2. ACCESSIBLE SPACES WERE SURVEYED FOR SUSPECT HAZARDOUS MATERIALS. WHEN
OBSERVED, THE MATERIALS WERE NOTED ON THE DRAWING.
3. IF ADDITIONAL SUSPECT ASBESTOS-CONTAINING MATERIALS ARE UNCOVERED DURING
DEMOLITION OR ABATEMENT, STOP WORK AND CONTACT THE ENVIRONMENTAL
CONSULTANT FOR VERIFICATION AND ADDITIONAL TESTING.
1. ASBESTOS-CONTAINING MATERIALS ARE PRESUMED IN WALL, FLOOR, CEILING CAVITIES,
AND CONCEALED SPACES THROUGHOUT THIS BUILDING.
LEGEND
ASBESTOS-CONTAINING GLUED-ON CEILING TILES
ASBESTOS-CONTAINING FLOOR TILE AND MASTIC
ASBESTOS-CONTAINING DEBRIS FIELD
2-12A 77053.000-2-12A (-) CEILING
ASBESTOS-CONTAINING TEXTURED CEILING MATERIAL
ASBESTOS-CONTAINING SHEET FLOOR COVERING
037 038
036 77053.000-036 (-)
037 77053.000-037 (-/+)
038 77053.000-038 (-)
DDDDDDDDDDDDDDD
GLUED-ON CEILING TILES
CEILING TEXURE, Room 229
CEILING TEXURE, Room 230
Dave Call Out Sample 39
Dave Call Out Sample 40
Dave Call Out Sample 41
Dave Call Out Sample 42
Dave Call Out Sample 43
Dave Call Out Sample 44
Dave Call Out Sample 45
Dave Call Out Sample 46
Dave Call Out Sample 47
Dave Call Out Sample 48
04/02/2021
04/02/2020
ASBESTOS INSPECTOR / MANAGEMENT
PLANNER REFRESHER
Course Date:
Expiration Date:Certificate: IMR-20-5871A for
Portland, ORCourse Location:
For verification of the authenticity of this certificate contact:
PBS Environmental
4412 SW Corbett Avenue
Portland, OR 97239
(503) 248-1939 Andy Fridley, Instructor
In accordance with TSCA Title II, Part 763, Subpart E, Appendix C of 40 CFR
CCB #SRA0615 4-Hr Training
HAS SUCCESSFULLY COMPLETED THE TRAINING COURSE
DAVE J ROUTTU
THIS IS TO CERTIFY THAT
CCB #SRA0615 4-Hr Training
File details come from the government source that posted it. Updated .