LBP_Inspection_Report.pdf
PDF 86 KB Posted
- Attached to
- Repair Fire Alarms in Bldg 238 Federal contract opportunity
- Solicitation number
- FA8201-16-B-0008
About this file
Lead Based Paint Survey (LBP)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_to_Solicitation_0002.pdf | ||
| SOW_238_mod_(002).pdf | ||
| FIRE_PROTECTION_128_129.pdf | ||
| ANSWERS_TO_CONTRACTOR_QUESTIONS.pdf | ||
| Amendment_to_Solicitation_2.pdf | ||
| FIRE_ALARM_128_129.pdf | ||
| FA8201-16-B-0008_-_Bldg_238_-_Fire_Alarms_-_Attendance_Records.pdf | ||
| Index_of_Specifications.pdf | ||
| Asbestos_Inspection_Report.pdf | ||
| Schedule_of_Drawings.pdf | ||
| SOW_238.pdf | ||
| KRSM238_152063_Electrical_Drawings_IFC_12-07-2015.pdf | ||
| Pricing_Schedule.pdf | ||
| 2016_05_05_BASE_FACILITY_DESIGN_STANDARD.pdf | ||
| B238_Solicitation.pdf | ||
| KRSM238_152063_Fire Protection Drawings IFC 12-07-2015.pdf | ||
| Davis_Bacon.pdf | ||
| SPECS.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building: 238 Replace fire alarm system with up to date system
WO#: 57334 11 July 2016 1400 Hours
DATE:
75TH CES/CEOHA
Building
Inspector:
Building
Note:
In order to print the entire LBP report select: "File", "Print", then select "Entire Workbook", "OK".
DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
FROM:
SUBJECT:
Inspection Date:
SCOPE OF WORK: Replace existing fire alarm system with updated system.
XRF Analyzer XL3t 300 (Serial #30660)
Traver Andreasen (Utah Certified Lead Inspector #PB-2085)
It is possible that lead based paint could be encountered during any renovation project. Additional identification for lead based paint on other building components may be required. The facility manager should ensure that these components are surveyed for lead as well, to meet OSHA Standard 29 CFR 1926.62 construction requirements for lead.
Built in:
Refer to "Readings" tab for all readings.
24-April-2014
Building 238
Niton:
3-The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1mg/cm² as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000 µg/g by dry weight) by laboratory analysis, or more of lead. All other components tested were less than 1 mg/cm².
4-Any effort to disturb lead paint can create lead dust. Please ensure that appropriate abatement, cleanup, and disposal will be accomplished and that the appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Nickolas King at 586-7094.
Traver Andreasen (Utah Certified Lead Inspector #PB-2085)
Inspector:
1-Lead based paint was non-detected. Please refer to specific results of this inspection; see attachment 1.
2-Limited lead-based paint identification has been completed for, 11-July-2016
ORGANIZATION:
Niton used for this inspection: XRF Analyzer XL3t 300 (Serial #30660)
REQUESTER:
57334 Lead Based Paint (LBP) Survey, WORK ORDER:
William Blackham
309 MXSG
Report