Asbestos_Inspection_Report.pdf
PDF 131 KB Posted
- Attached to
- Repair Fire Alarms in Bldg 238 Federal contract opportunity
- Solicitation number
- FA8201-16-B-0008
About this file
Asbestos Survey
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_to_Solicitation_0002.pdf | ||
| SOW_238_mod_(002).pdf | ||
| Amendment_to_Solicitation_2.pdf | ||
| FIRE_ALARM_128_129.pdf | ||
| FIRE_PROTECTION_128_129.pdf | ||
| ANSWERS_TO_CONTRACTOR_QUESTIONS.pdf | ||
| FA8201-16-B-0008_-_Bldg_238_-_Fire_Alarms_-_Attendance_Records.pdf | ||
| Index_of_Specifications.pdf | ||
| LBP_Inspection_Report.pdf | ||
| 2016_05_05_BASE_FACILITY_DESIGN_STANDARD.pdf | ||
| B238_Solicitation.pdf | ||
| KRSM238_152063_Fire Protection Drawings IFC 12-07-2015.pdf | ||
| Schedule_of_Drawings.pdf | ||
| SOW_238.pdf | ||
| KRSM238_152063_Electrical_Drawings_IFC_12-07-2015.pdf | ||
| Pricing_Schedule.pdf | ||
| Davis_Bacon.pdf | ||
| SPECS.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS
N/A
RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations.
This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering laboratory at Hill Air Force Base, Utah.
Entire Facility Remove entirefire alarm system.
Replace with new, up-to-date fire alarm system.
Affected Area:
March 2014 William Blackham
309 MXSG
Date Requested:
Requester:
Organization:
Location & Building:
Inspector:
57334
Statement of Work:
DEPARTMENT OF THE AIR FORCE
75 CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
REPLACE & UPDATE FIRE ALARM SYSTEM
HILL AFB BUILDING, 238
Inspection Date:
Work Order:
LIMITED ASBESTOS INSPECTION REPORT, HILL AFB BUILDING, 238
*Per UDAQ definition.
QUANTITY
N/AN/AN/A
24 April 2016 Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397)
*RACM
*Category I *Category II
FRIABILITY
(During
Removal)*
N/A N/A
SUMMARY OF ASBESTOS CONTAINING MATERIALS FOUND
Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing building materials (ACM) that could potentially be encountered in this area. The information gathered from all current and previous inspections is shown below by homogenous area.
MATERIAL TYPE *LOCATIONS FOUND
Building: 238 Replace fire alarm system
WO#: 57334
11 July 2016 1415 Hours
A total of 40 8
Drywall/Joint Compound Wall System, 20,000 Square Feet
GM141358 Northeast, B-2 Area None-Detected
GM141359
North Center, Southeast
Mezzanine None-Detected
GM141360
South Center, Plating
Room None-Detected
GM141361 North Center, Room 150 None-Detected
Drywall/Joint Compound Ceiling System, 100 Square Feet
ASBESTOS
N/A
MATERIAL TYPE
N/A
Drywall/Joint Compound Wall System Sound Deadening Wall Panel Ceiling Tile 2'x2' Pockmarks/Pinholes, White
GM141354 Southwest, Room 166 None-Detected GM141355 North Center, Room 208 None-Detected GM141356 South Center, Sink Area None-Detected GM141357 Southwest, B-2 Area None-Detected
The following table summarizes the sampling data.
Homogenous Building Material, Description, Location, Quantity.
Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project.
Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than 1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
Ceiling Tile, 2'x2' Textured, White Ceiling Tile, 2'x4' Similated Pockmarks/Pinholes, White suspect materials assesses as part of the inspection.
Sample #
Drywall/Joint Compound Ceiling System
Summary of materials containing ≤1% was identified via "Point Counting". ≤1% is not considered to be an asbestos containing material, but special handling/packaging requirements are necessary per OSHA 29CFR 1926.1101 and
29CFR 1910.1001
Ceiling Tile 2'x4' Pockmarks/Pinholes, White Ceiling Tile 2'x4' Wormygrooves/Pinholes, White
QUANTITY *LOCATIONS FOUND
N/A N/A
Sample Location
Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM).
Results
The following is a list of the "Suspect Materials" that were sampled as part of this inspection:
samples reference the
WO#: 57334
11 July 2016 1415 Hours
Sound Deadening Wall Panel, Off-White, 1,000 Square Feet
Ceiling Tile 2'x2' Pockmarks/Pinholes Pattern, White, 1,200 Square Feet
Ceiling Tile, Pockmarks/Pinholes Pattern, White, 900 Square Feet
GM141364 Northeast, 2-EP None-Detected GM141365 Southeast, B-2 Area None-Detected GM141366 Northwest, B-2 Area None-Detected
GM141367
Southwest, Eagle Ave.
Hallway None-Detected
GM141368 Northwest, B-2 Area None-Detected GM141369 East Center, Room 171 None-Detected
GM141362
Exterior Northeast, Room
13040 None-Detected
GM141363 Southwest, Room 121 None-Detected
GM141381
Exterior , Confernece
Room None-Detected
GM141382
None-Detected northeast, Room 162 None-Detected
GM141379
Southeast, 530th Break
Room None-Detected
GM141380 Center, 530th Break Room None-Detected Ceiling This 2'x4' Wormygrooves/Pinholes
Pattern, White, 1,200 Square Feet
GM141370 Southwest, DLA Room 121 None-Detected
GM141371 Center, "Old Grind Room" None-Detected
GM141378 None-Detected
None-Detected
GM141384 Southeast, Room 202 None-Detected
Southeast, 2nd Floor NW Engineer Mezzanine
GM141375 South Center, Room 150 None-Detected
GM141376
GM141383
Southeast, APIS Inspector
Office
Hallway, Exterior Rooms 151 & 154
Southeast, Room 174 None-Detected
None-Detected
None-Detected
GM141377
Southwest, Entry Room
GM141372
GM141373
Southeast, Facility Engineer's Office
None-Detected
GM141374 Northwest, Room 168
None-DetectedNortheast, Room, Exterior Room 208
GM141385
Ceiling Tile 2'x2' Textured Pattern, White, 100
Square Feet GM141386 Northwest, Room 202 None-Detected
WO#: 57334
11 July 2016 1415 Hours
POTENTIAL FOR ADDITIONAL MATERIALS:
Per EPA requirements, all materials analyzed as containing ≤10% asbestos are point counted utilizing EPA method 600/R-93/116.
Asbestos/LBP Shop (801)777-8006
This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building.
Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance.
This report was inspected by:
Traver Andreasen (Utah Certified Asbestos Inspector ASB#-4397) of the 75 CES/CEOHA Asbestos/LBP Shop.
Cell: (801)430-4785 Supervisor: Nickolas King: DSN: (801)586-7094
Asbetsos/LBP Shop 75 CES(CEOHA)
GM141393
Southeast, 2nd Floor
MXDVAAA Office None-Detected
2'x4' Similated Ceiling Tile, Pockmarks/Pinholes Pattern, White, 500
Square Feet
GM141391
Southwest, Painter Loading Dock Room
None-Detected
GM141392 Northwest, Room 112E
GM141387
Northwest, Entry Room
None-Detected
CONTACT INFORMATION
None-Detected
GM141388 Southeast, Room 164 None-Detected
GM141389
Nothwest, Mezzanine
Office Area None-Detected
GM141390
Northwest, 530th CMMXS
Office in SE Mezzanine Area
None-Detected