Text version
Questions for
FA8125-09-R-0002
Lease & Maintenance of De-ionized Water Purification Systems
Question 1: CLIN 0001 and CLIN 0002 does cost need to be provided for each CLIN?
Response: No. CLIN 0001 and 0002 are informational CLIN’s only. Each of these CLIN’s has stated that this is for the total units 39 de-ionized water purification systems for the entire project.
Question 2: CLIN 0001AA and 0002AA does cost need to be provided?
Response: Yes, this is where the cost should be reflected. This is a breakout of the total 39 units required for the entire project. CLIN 0001AA – 29 units and CLIN 0002AA – 10 units.
Question 3: On CLIN 1001, 1002, 2001, 2002, 3001, 3002, 4001 and 4002 which number is correct the thirty-nine or (10)?
Response: On CLIN 1001, 1002, 2001, 2002, 3001, 3002, 4001 and 4002, disreguard the thirty-nine. The number in the parentheses is the correct information on each CLIN number.
CLIN 1001, 2001, 3001 and 4001 - 29 de-ionized water purification systems
CLIN 1002, 2002, 3002 and 4002 – 10 de-iionized water purification systems.
File details come from the government source that posted it. Updated .