RESPONSES TO QUESTIONS
QUESTION: Since this is a repair/overhaul contract (and not a remanufacture contract) I presume we may utilize serviceable components to repair/overhaul these valves? In other words, we use commercially serviceable parts to return these end item valves back to serviceable condition, correct?
RESPONSE: The Government intends to award a services contract as a result of this solicitation. The overhaul efforts described in the PWS require that any parts replaced to bring the TCCV to a serviceable condition be new and unused. The PWS will be changed to reflect this requirement and will be incorporated with an amendment to the solicitation.
QUESTION: Are you the appropriate person to provide the full documents pertaining to the incorporated clauses?
RESPONSE: If you are referring to the clauses that are part of the solicitation package, your responses should be included in your proposal and sent to Ann Redwine.
QUESTION: Is electronic submittal (i.e. e-mail) acceptable/preferable?
RESPONSE: Electronic submittal (i.e. e-mail) of your proposal is acceptable and preferred.