Responses_to_Contractor_Questions.docx

DOCX document 14 KB Posted

Attached to
F108 TURBINE CLEARANCE CONTROL VALVE
Solicitation number
FA8122-14-R-0015
Issued by

View the file

Other files

File Type Posted
FA812214R0015_______0007.RTF RTF text file
FA812214R0015_______0006.RTF RTF text file
FA812214R0015_______0006_TCCVEvaluationLPTA.docx DOCX document
FA812214R0015_______0006_TCCVAdditionalITOs.docx DOCX document
Responses_to_Contractor_Questions_04_Nov_14.docx DOCX document
FA812214R0015_______0005_TCCVAdditionalITOs.docx DOCX document
FA812214R0015_______0005.RTF RTF text file
FA812214R0015_______0005_TCCVEvaluationLPTA.docx DOCX document
Responses_to_Contractor_Questions_29_Oct_14.docx DOCX document
FA812214R0015_______0004.RTF RTF text file
FA812214R0015_______0003_TCCV_PWS_02_Oct_14.docx DOCX document
FA812214R0015_______0003.RTF RTF text file
Q A.docx DOCX document
FA812214R0015_______0002.RTF RTF text file
FA812214R0015_______0002_PWS.docx DOCX document
Responses_to_Contractor_Questions2.docx DOCX document
FA812214R0015_______0001.RTF RTF text file
FA812214R0015_ExhibitACDRLs.pdf PDF
FA812214R0015_PackagingRequirementsForm158.pdf PDF
FA812214R0015_PWS.docx DOCX document
FA812214R0015.RTF RTF text file
Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RESPONSES TO QUESTIONS

QUESTION: Since this is a repair/overhaul contract (and not a remanufacture contract) I presume we may utilize serviceable components to repair/overhaul these valves? In other words, we use commercially serviceable parts to return these end item valves back to serviceable condition, correct?

RESPONSE: The Government intends to award a services contract as a result of this solicitation. The overhaul efforts described in the PWS require that any parts replaced to bring the TCCV to a serviceable condition be new and unused. The PWS will be changed to reflect this requirement and will be incorporated with an amendment to the solicitation.

QUESTION: Are you the appropriate person to provide the full documents pertaining to the incorporated clauses?

RESPONSE: If you are referring to the clauses that are part of the solicitation package, your responses should be included in your proposal and sent to Ann Redwine.

QUESTION: Is electronic submittal (i.e. e-mail) acceptable/preferable?

RESPONSE: Electronic submittal (i.e. e-mail) of your proposal is acceptable and preferred.