G-3_C4I_Electronics_Data_Collection_ReqTemplate_-_30_Oct_15.xlsx

XLSX spreadsheet 2 MB Posted

Attached to
Cost Estimating and Modeling (CEM) Federal contract opportunity
Solicitation number
FA7014-16-R-5004
Issued by
Department of the Air Force Headquarters District Washington

About this file

Attachment G-3

View the file

Other files for this federal contract opportunity

Other files attached to Cost Estimating and Modeling (CEM), newest first.
File Type Posted
Attachment_L-AFCAA_Notional_POAM.xlsx XLSX spreadsheet
Attachment_I_Total_Proposed_Pricing_Worksheet_20160627.Rev.xlsx XLSX spreadsheet
Attachment_O-FINAL_Q AS_20160630.pdf PDF
SF_30_FA7014-16-R-5004_AMEND_0005.pdf PDF
FINAL_CEM_Solicitation_20160627.pdf PDF
Attachment_I_Total_Proposed_Pricing_Worksheet_20160627.Rev.xlsx XLSX spreadsheet
Attachment_O.1-ADDITIONAL_Q AS.pdf PDF
SF_30_FA7014-16-R-5004_AMEND_0004.pdf PDF
FINAL_CEM_Solicitation_20160623.pdf PDF
Attachment_O.1-QUESTION_AND_ANSWERS_FROM_RFP.pdf PDF
Attachment_B_CEM_Fee_Schedule_20160620.xlsx XLSX spreadsheet
Attachment_I_Total_Proposed_Pricing_Worksheet_20160622.xlsx XLSX spreadsheet
Attachment_M_Technical_Reference_Matrix_FA7014-16-R-5004.docx DOCX document
Section_L-_2_Volume_III_Past_Performance_Information_Form.docx DOCX document
FINAL_CEM_Solicitation_20160622.pdf PDF
SF_30_FA7014-16-R-5004_AMEND_0002_Q As.pdf PDF
SF_30_FA7014-16-R-5004_AMEND_0001_1.pdf PDF
Attachment_H._1_-TDN_Instructions.pdf PDF
G-4_EW_PMP_Data_Collection_Requirements_Template_-_30_Oct_15.xlsx XLSX spreadsheet
G-9_Space_Data_Collection_Requirements_Template_-_28_Oct_15.xlsx XLSX spreadsheet
Section_L-_3_Past_Performance_Questionnaire.docx DOCX document
G-2_AIS_Data_Collection_Requirements_Template_-_29_Oct_15.xlsx XLSX spreadsheet
Section_L-1_Cross_Reference_Matrix_FA7014-16-R-5004.docx DOCX document
Section_L-_2_Volume_III_Past_Performance_Information_Form.docx DOCX document
Attachment_N_Visitors_Pass.pdf PDF
G-8_Radar_Data_Collection_Requirements_Template_-_30_Oct_15.xlsx XLSX spreadsheet
Attachment_I_Total_Proposed_Pricing_Worksheet_20160603.xlsx XLSX spreadsheet
Attachment_B_CEM_Fee_Schedule_20160504.xlsx XLSX spreadsheet
Attachment_M_Technical_Reference_Matrix_FA7014-16-R-5004.docx DOCX document
Attachment_K.3_to_DD254_-_Item_10b_RD_20160210.rtf RTF text file
G-1_Aircraft_Data_Collection_Req_Template_-_30_Oct_15.xlsx XLSX spreadsheet
Section_L-5_Questionnaire_Cover_Letter.pdf PDF
G-10_UAV_Data_Collection_Requirements_Template_-_30_Oct_15.xlsx XLSX spreadsheet
Section_M_-_M0002_Pricing_Reference_Matrix_FA7014-16-R-5004.docx DOCX document
Attachment_H_-_Technical_Direction_Memo_Form_CEM.pdf PDF
G-6_Launch_Vehicle_Data_Collection_ReqTemplate_-_28_Oct_15.xlsx XLSX spreadsheet
Attachment_K.1_to_DD254-_Block_13_20160210.doc DOC document
FINAL_CEM_Solicitation_20160603.pdf PDF
Attachment_K.2_to_DD254-_Item_10a_COMSEC_20160210.rtf RTF text file
G-7_Missile_Data_Collection_Requirements_Template_-_3_Nov_15.xlsx XLSX spreadsheet
G-5_ICBM_Data_Collection_Requirements_Template_-_28_Oct_15.xlsx XLSX spreadsheet
Attachment_K.4_to_DD254_-_Item_10d_FRD_20160210.rtf RTF text file
Attachment_K_DD254_AFCAA_CEM-20160506.pdf PDF
Attachment_J_CEM_QASP_FINAL_20160525.pdf PDF
Attachment_L_AFCAA_POAM.xlsx XLSX spreadsheet
Attachment_O_Industry_Day_Draft_Pre-Sol_Q As.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PMP Hardware Technical Template

HardwareTechnicalTableUNCLASSIFIED, FOR OFFICIAL USE ONLYTagName1TagValue1
AFCAA CEM TemplatesTagName2TagValue2
PMP Hardware Technical Template, C4I ElectronicsTagName3TagValue3
ColumnHeadSecond Reference Design (e.g. Contractor A)Third Reference Design (e.g. Contractor B)Time each parameter is expected to be available
WBS/CRS NumberWBS/CRS ElementParameter NameValueLowHighMarginUnit of MeasureUnit QualifierEstimate or ActualObjectiveThresholdSourceNotesValueLowHighMarginUnit of MeasureUnit QualifierEstimate or ActualSourceNotesValueLowHighMarginUnit of MeasureUnit QualifierEstimate or ActualSourceNotesDefinitionVocabularyIDList Item 1List Item 2List Item 3List Item 4List Item 5List Item 6List Item 7List Item 8List Item 9List Item 10List Item n = _MS APDRMS BCDR
1.0Electronic System - C4I ElectronicsC4I Electronics is an object-detection system that uses radio waves to determine the range, altitude, direction, or speed of objects. This summary element includes the complex of equipment (hardware/software), data, services, and facilities required to develop and produce an electronic system capability for a specific C4I Electronics system. The WBS should include elements listed below as appropriate to the C4I Electronics design that is being designed and built. Some elements will not be necessary depending on the type of design (mechanically steered antenna, electronically scanned array, active electronically scanned array, or a hybrid approach).
Development EffortListListListChoice List: (1) New C4I Electronics Development or (2) Existing C4I Electronics System Modification or (3) OtherModifiedNew C4I Electronics SystemExisting C4I Electronics System ModificationOtherxxxx
Modification Scope - C4I ElectronicsDescriptionDescriptionDescriptionDescribe scope of C4I Electronics modification, if modification effortxxxx
Target EnvironmentListListListChoice List: Ground, Maritime, Airborne or SpaceModifiedGroundMaritimeAirborneSpaceOtherXXXX
PlatformListListListSpecify specific platform type where C4I Electronics system will be employed.ModifiedUAVSmall/Fighter/HeloLarge/BomberLarge/TransportGround/fixedGround/ transportableMan-PortableMaritime- Ship BasedMartime - Shore BasedOtherXXXX
Infrastructure AvailabilityListListListChoice List: Rate 1 - 5; (1) None available, no shelter, connectivity or power; (5) Full connectivity, environmentally controlledModified12345Otherxxxx
1.1Prime Mission ProductThe hardware and software used to accomplish the primary mission of the defense materiel item. This WBS element includes the design, development, and production of complete units (i.e., the prototype or operationally configured units, which satisfy the requirements of their applicable specifications, regardless of end use) and is comprised of the sub elements listed below
1.1.1PMP Subsystem Terminal 1…nThe hardware and software components of the specific electronic subsystem.
Terminal FunctionDescriptionDescriptionDescriptionSpecify terminal function such as a transponder, receiver, transmitter or datalink.xxxx
Frequency RangeMegahertzMegahertzMegahertzA continuous range or spectrum of frequencies that extends from one limiting frequency to another. Note 1: The frequency range for given equipment specifies the frequencies at which the equipment is operable. For example, filters pass or stop certain bands of frequencies. The frequency range for propagation indicates the frequencies at which electromagnetic wave propagation in certain modes or paths is possible over given distances. Frequency allocation, however, is made in terms of bands of frequencies.Modifiedxxxx
Frequency BandListListListA frequency band is a small section of the spectrum of radio communication frequencies, in which channels are usually used or set aside for the same purpose. Specify by designated letter.NewLSCXKuKKaOtherxxxx
WaveformListListListThe representation of a signal as a plot of amplitude versus time. Examples include: CDL, Link16, IFDL, MADL, etc.CDLLink16IFDLMADLOtherxxxx
ComplexityListListListChoice List: Simple - UHF/VHF, AM, FM; Medium - HAVE QUICK, Link-16; High - CDL, IFDL, MADL
ModifiedSimple - UHF/VHFMedium - HAVE QUICK, Link-16High - CDL, IFDL, MADLOtherxxxxxGovernment11
Anti-Jamming CapabilityListListListSpecify whether terminal contains measures to ensure that intended transmitted information can be received despite deliberate jamming attempts. Choice List: (Y) Yes or (N) No.YesNoxxxxxGovernment11
Waveform CapabilityListListListWhether the waveform is capable of Low Probability of Intercept/Low Probability of Detection (LPI/LPD). Choice List: LPI of LPD.LPILPDOtherxxxxContractor11
Modulation TypeListListListThe process, or result of the process, of varying some characteristic of a carrier, in accordance with an information-bearing signal. Choice List: A = Amplitude Modulation; F = Frequency Modulation; P = Phase Modulation.AM = Amplitude ModulationFM = Frequency ModulationPM = Phase ModulationOtherxxxxContractor11
Number of ChannelsQuantityQuantityQuantityA physical transmission medium or a logical connection over a multiplexed medium; used to convey an information signal from one or several senders or transmitters to receivers.xxxxxGovernment11
Electromagnetic Compatibility (EMC)ListListListElectromagnetic compatibility (EMC) is the ability of systems, equipment, and devices that utilize the electromagnetic spectrum to operate in their intended operational environments without suffering unacceptable degradation or causing unintentional degradation because of electromagnetic radiation or response.

Low - Minimal Internal/External cosite considerations Medium - Moderate addressing of internal cosite

High - Designed to work in close proximity with other radios receiving and transmittingLowMediumHighOtherxxxxxGovernment33
Environmental Tolerance - AltitudeListAltitudeListAltitudeListAltitudeEnvironmental tolerance refers to radar environmental constraints ro requirements such as altitude. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - FluidListFluidListFluidListFluidEnvironmental tolerance refers to radar environmental constraints ro requirements such as fluid. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - FogListFogListFogListFogEnvironmental tolerance refers to radar environmental constraints ro requirements such as fog. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - FungusListFungusListFungusListFungusEnvironmental tolerance refers to radar environmental constraints ro requirements such as fungus. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - HumidityListHumidityListHumidityListHumidityEnvironmental tolerance refers to radar environmental constraints ro requirements such as humidity. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - Radiation HardeningListRadiation HardeningListRadiation HardeningListRadiation HardeningEnvironmental tolerance refers to radar environmental constraints ro requirements such as radiation hardening. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - SaltListSaltListSaltListSaltEnvironmental tolerance refers to radar environmental constraints ro requirements such as salt. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - ShockListShockListShockListShockEnvironmental tolerance refers to radar environmental constraints ro requirements such as shock. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - TemperatureListTemperatureListTemperatureListTemperatureEnvironmental tolerance refers to radar environmental constraints ro requirements such as temperature. Identify if this environmental tolerance applies.NewYesNoxxxxxGovernment33
Environmental Tolerance - VibrationListVibrationListVibrationListVibrationEnvironmental tolerance refers to radar environmental constraints ro requirements such as vibration. Identify if this environmental tolerance applies.ModifiedYesNoXXXXXGovernment33
1.1.1.1HardwareA device capable of sending, receiving, or sending and receiving information over a communications channel.
WeightPoundsPoundsPoundsPhysical weight of the terminal.xxxxContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor22
Power - InputWattsInputWattsInputWattsInputPower required to operate the terminal.xxxxContractor13
Total Printed Circuit BoardsQuantityPCB CompoonentsQuantityPCB CompoonentsQuantityPCB CompoonentsNumber of printed circuit boards (PCBs) in the terminal. This includes all boards designed, modified, purchased or provided as customer furnished equipment that will eventually be assembled into the terminal.xxxxContractor33
ASIC DesignsQuantityASICsQuantityASICsQuantityASICsEnter the number of Application Specific Integrated Circuit (ASIC) (unspecified type) designs required - See HW Tech Table - SRU.NewxxxxContractor33
FPGA DesignsQuantityFPGAsQuantityFPGAsQuantityFPGAsEnter the number of Field Programmable Gate Array (FPGA) (unspecified type) designs required - See HW Tech Table - SRU.NewxxxxContractor33
Number of SRUs per LRUQuantityEnter the number of SRUs per LRU. See HW Tech Table - SRU.NewxxxxContractor12
Data RateMegabits per SecondMegabits per SecondMegabits per SecondThe speed at which information is transferred through a communications or computing medium; measured in bytes per second.ModifiedxxxxContractor23
Quantity of InterfacesQuantityby Unique InterfacesQuantityby Unique InterfacesQuantityby Unique InterfacesA shared boundary between two functional units, defined by specific attributes, such as functional characteristics, common physical interconnection characteristics, and signal characteristics. Examples include: 1553 bus, Ethernet, RF, ARINC-429xxxxContractor23
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.1.2Software Release 1…nThe resources associated with the PMP subsystem software that is associated with the PMP subsystem for release 1…n. A software release is an aggregate of one or more CSCIs that satisfies a specific set or subset of requirements. When incremental, spiral, or other software development methods are used, multiple releases may be necessary to meet program requirements.
1.1.1.2.1CSCI (1…n)See Software Development TemplateSee Software Development TemplateSee Software Development TemplateA release is a separately tested and delivered product. Within releases are CSCIs. When a release is complete, a portion or all of one or more CSCIs will be completed. Therefore, a CSCI may appear in one or more releases, but will be successively more functional as each release is completed
Software LanguageTextTextTextThe predominant computer language in which the development was conducted.CEMVocabXXXXContractor2
Product Size - DeliveredSLOCSLOCSLOCThe delivered size of the product developed, not including any code that was needed to assist development but was not delivered (such as temporary stubs, test scaffoldings, or debug statements). SLOC shall reflect logical size, as opposed to physical, etc.CEMVocabXXXXContractor2
Product Size - EffectiveSLOCThe equivalent size for the adjusted size of the product developed.CEMVocabXXXXContractor1
ESLOC EquationTextThe equation used to derive Equivalent Source Lines of Code (ESLOC).CEMVocabXXXXContractor2
New CodeSLOCSLOCSLOCThe delivered size of the product developed that is human generated.CEMVocabXXXXContractor1
Modified CodeSLOCSLOCSLOCModified code is defined as pre-developed code that can be incorporated in the software component with a significant amount of effort, but less effort than required for a newly developed code.CEMVocabXXXXContractor1
Reused CodeSLOCSLOCSLOCCode from external sources (government-furnished or otherwise) that is included and resused without modification. However, there may be an amount of retest required.CEMVocabXXXXContractor1
Carryover CodeSLOCSLOCXXXXContractorPre-existing code that has already been introduced into the baseline for this software product during a previous build. For example, if code from Build 1 is continued in the baseline for Build 2, it is likely to require additional effort for functional and regression testing during the delivery of Build 2. Carryover code is different from "reused" code from a separate program or source as the effort to understand and get it integrated into this program's baseline has already occured in an earlier build for this program.XXXXContractor2
Auto-generated codeSLOCSLOCXXXXContractorNew code that is automatically generated using a code generating tool. These tools will generate many lines for each selection or instruction typed by a human. It is important to keep this separate from human generated new code because effort per line of code is much less for autogenerated than human generated (i.e., if included it would over estimate effort if used in a parametric model or a productivity-based estimate; if included as the basis of a productivity metric for future use it will understate the effort required if the new system has only human generated code).XXXXContractor3
1.1.1.3Subsystem IntegrationAll of the resources in order to perform integration, assembly, test, and check out of the PMP. This is the process of combining and evaluating CSCIs and Hardware of a system or segment of a system that have undergone individual CSCI and hardware qualification testXXXX
New IntegrationListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNew DesignModified DesignComplete ReusexxxxContractor11
Number of Hardware InterfacesQuantityQuantityQuantityA hardware interface is described by the mechanical, electrical and logical signals at the interface and the protocol for sequencing them (sometimes called signaling).The quantity of hardware interfaces across the system.xxxxContractor11
Integration ComplexityQuantityQuantityQuantityUnique situation related to integration/racking/size. Choice List: 1) Low: simple, straightforward interfaces and verification testing, roll on, roll off, cargo plane; 2) Moderate: generally common interfaces with some higher complexity subsystem interfaces and verification testing, racks installed on other a/c ; 3) High: multiple, new and complex interfaces and verification testing and calibration, Pod, small UAV.
LowModerateHighxxxxContractor11
Multiple Classification LevelsListListListWhether there is a separation of classified information and unclassified information (red-black separation); Multiple classification levels operating on network. Choice List: (Y) Yes or (N) No.YesNoxxxxxGovernment22
CertificationListListListSpecify if terminal is military/air worthiness certifiedYesNoxxxxContractor22
1.1.2Antenna 1…n
Antenna TypeListDirectionListDirectionListDirectionChoice List: 1) Omnidirectional Antenna is an antenna that has a radiation pattern that is nondirectional in azimuth; 2) A Directional Antenna is any antenna that is not Omnidirectional.Omnidirectional AntennaDirectional AntennaOtherxxxxContractor11
Frequency RangeMegaHertzMegaHertzMegaHertzThe frequency range of the RF, microwave or other radio signals that the antenna is designed to efficiently collect or radiate. Frequency is the number of cycles per second or hertz that the radio signals or electromagnetic wave oscillates at. Specify the primary frequency range of the antenna.xxxxxGovernment13
Gain - AntennaDecibelsDecibelsDecibelsThe ratio of the power required at the input of a loss-free reference antenna to the power supplied to the input of the given antenna to produce, in a given direction, the same field strength at the same distance.xxxxContractor22
LengthInchesInchesInchesLength of the antenna in inches.xxxxContractor22
Antenna TypeListListListSpecify antenna type. Examples include Whip, Dipole, Slotted Waveguide, Horn, Dish/Reflector, Phased Array, etc.ModifiedWhipDipoleSlotted WaveguideHornDish/ReflectorPhased ArrayOtherxxxxContractor11
CertificationListListListDoes item meet military specifications? Choice List: 1) Yes; 2) NoNewYesNoxxxxContractor22
Installation LocationListListListChoice List: 1) Fore; 2) Aft; 3) fin; 4) Wing tip; 5) Blade; 6) OtherNewForeAftFinWing tipBladeOtherxxxxContractor33
Effective Radiated Power (ERP)WattsWattsWattsThe power supplied to the antenna multiplied by the relative gain of the antenna in a given direction.xxxxContractor13
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.3Amplifier 1…nAn electronic device that increases the power of a signal.
GainDecibelsDecibelsDecibelsThe ratio of output to input powerxxxxContractor12
BandwidthDecibelsDecibelsDecibelsThe range of frequencies for which the amplifier gives a level of performance. Can be defined as the difference between the lower and upper half power points.xxxxContractor12
EfficiencyPercentagePercentagePercentageThe measure of how much the power source is usefully applied to the amplifier's output.xxxxContractor12
WeightPoundsPoundsPoundsPhysical Weight of the item.xxxxContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor23
WidthInchesInchesInchesThe width of the item.
xxxxContractor23
DepthInchesInchesInchesThe depth of the item.
xxxxContractor23
Slew RateVolts per SecondVolts per SecondVolts per SecondThe maximum rate of change of output voltage per unit of time and is expressed as volts per second.xxxxxGovernment23
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.4Processor 1…nGeneral purpose digital computer; data processor controls and performs routine computations for all units of the Electronic Communications System.
Processor TypeListListListChoice List: 1) Data Processor; 2) Signal Processor; 3) OtherNewData ProcessorSignal ProcessorOtherxxxxContractor13
WeightPoundsPoundsPoundsPhysical weight of the item.xxxxContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor22
Performance (Throughput)Floating Point Operations Per SecondGiga Floating Point Operations Per SecondGiga Floating Point Operations Per SecondThe amount of useful work accomplished by a computer system compared to the time or resources inFloating Point Operations Per Second (FLOPS)xxxxxGovernment12
Memory CapacityGigabytesGigabytesGigabytesMemory Capacity is defined as the maximum amount of data storage in Gigabytes that a computer contains. Specify capacity in Gigabytes to store programs or data on a temporary or permanent basis.xxxxxGovernment12
Data RateMega bits per secondMega bits per secondMega bits per secondThe speed at which information is transferred through a communications or computing medium; measured in bytes per second.ModifiedxxxxContractor22
ASIC DesignsQuantityQuantityQuantityEnter the number of Application Specific Integrated Circuit (ASIC) (unspecified type) designs required - See HW Tech Table - ASIC & FPGA.NewxxxxContractor33
FPGA DesignsQuantityQuantityQuantityEnter the number of Field Programmable Gate Array (FPGA) (unspecified type) designs required - See HW Tech Table - ASIC & FPGA.NewxxxxContractor33
Clock SpeedMegahertzMegahertzMegahertzThe rate at which the processor can complete a processing cycle (CPU speed).NewxxxxContractor23
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.5Encryption Equipment 1…nThis element refers to any equipment that encrypts and/or decrypts payload data. Encryption devices used for communications security (COMSEC) such as Traffic Encryption Keys (TEK) and Crypto Ignition Keys (CIK).
WeightPoundsPoundsPoundsPhysical weight of the item.xxxxContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor22
Number of InterfacesQuantityQuantityQuantityA shared boundary between two functional units, defined by specific attributes, such as functional characteristics, common physical interconnection characteristics, and signal characteristics. Examples include: 1553 bus, Ethernet, RF, ARINC-429xxxxContractor22
Data RateMega bits per secondMega bits per secondMega bits per secondThe speed at which information is transferred through a communications or computing medium; measured in bytes per second.xxxxContractor22
Encryption TypeTextTextTextSpecify Encryption Type. Examples include Wired Equivalent Privacy (WEP), Wi-Fi Protected Access (WPA), WPA2,xxxxContractor22
Encryption StrengthBitsBitsBitsBits of the key in a cryptographic algorithmxxxxContractor33
FIPS Certification LevelListListListFour levels of security as defined by Federal Information Processing Standard (FIPS) Publication 140-2. Ranked lowest (1) - highest (4)Level 1Level 2Level 3Level 4xxxxxGovernment
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.6Avionics Interface Device 1…nThis element refers to the hardware used to interface with the aircraft, network, or communications hardware. It includes networking hardware, cables, racks, etc.
WeightPoundsPoundsPoundsSpecify item weight in poundsXXXXContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor22
Data RateMega bits per secondMega bits per secondMega bits per secondThe speed at which information is transferred through a communications or computing medium; measured in bytes per second.xxxxContractor12
Memory - RAMMegabytesMegabytesMegabytesA read/write, nonsequential-access memory used for the storage of instructions and data.xxxxContractor12
Quantity of InterfacesQuantityQuantityQuantityA shared boundary between two functional units, defined by specific attributes, such as functional characteristics, common physical interconnection characteristics, and signal characteristics. Examples include: 1553 bus, Ethernet, RF, ARINC-429xxxxContractor33
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.7Power SupplyThis element refers to the hardware that generates, converts, regulates, stores and distributes electrical energy to the payload.
1.1.7.1Power Supply Box 1…nAny power supply in the form of a box.
WeightPoundsPoundsPoundsSpecify item weight in poundsxxxxContractor11
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor22
Power TypeListListListChoice List: (1) DC (2) ACDCACOtherxxxxContractor12
Power - Delivered to SystemKilowattsKilowattsKilowattsThe power in kilowatts delivered to the systemxxxxContractor12
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.7.2Other Power Supply 1…nAny power supply other than a box, such as power distribution units, panels, circuit breakers, power converters and UPS, all at the LRU/SRU level.
Power TypeListListListChoice List: (1) DC (2) ACDCACOtherxxxxContractor11
WeightPoundsPoundsPoundsThe weight of the item.
xxxxContractor22
LengthInchesInchesInchesThe length of the item.
xxxxContractor22
WidthInchesInchesInchesThe width of the item.
xxxxContractor22
DepthInchesInchesInchesThe depth of the item.
xxxxContractor23
Power - Delivered to SystemKilowattsKilowattsKilowattsThe power in kilowatts delivered to the systemxxxxContractor12
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.8Ancillary Network Equipment
1.1.8.1Switches 1…nIn networks, the device that filters and forwards packets between LAN segments.New
Number of InterfacesQuantityQuantityQuantityA shared boundary between two functional units, defined by specific attributes, such as functional characteristics, common physical interconnection characteristics, and signal characteristics. Examples include: 1553 bus, Ethernet, RF, ARINC-429xxxxContractor11
ThroughputBits per secondBits per secondBits per secondThe number of bits, characters, or blocks passing through a data communication system, or portion of that system. Note: throughput is expressed in data units per period of time.xxxxContractor13
Design ReuseListListListChoice List: 1) New Design; 2) Modified Design; 3) Complete ReuseNewNew DesignModified DesignComplete ReuseXXXXContractor12
Technology Readiness Level (TRL)ListListListTechnology Readiness Levels (TRL)are a set of nine graded definitions/descriptions of stages of technology maturity. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: TRL level 1-9123456789XXXXContractor13
Manufacturing Readiness Level (MRL)ListListListManufacturing Readiness Levels are a set of nine graded definitions/descriptions of stages to assess the maturity of manufacturing readiness. They were originated by the National Aeronautics and Space Administration and adapted by the DOD for use in its acquisition system. Choice List: MRL level 1-9New123456789XXXXContractor13
Source TypeListListListCommercial off-the-shelf (COTS) is a Federal Acquisition Regulation (FAR) term for commercial items available in the commercial marketplace that can be bought and used under government contract. Non-Developmental Item (NDI) according to (FAR 2.101) means:

1.Any previously developed item of supply used exclusively for governmental purposes by a Federal agency, a State or local government, or a foreign government with which the United States has a mutual defense cooperation agreement;

2.Any item described in paragraph (1) of this definition that requires only minor modification or modifications of a type customarily available in the commercial marketplace in order to meet the requirements of the procuring department or agency; or

3.Any item of supply being produced that does not meet the requirements of paragraphs (1) or (2) solely because the item is not yet in use.A Build item is a component that is not commercially available and that requires design, development and test effort before suitable for operational deployment. Choice List: (1) COTS; (2) NDI; (3) BuildCOTSNDIBuildXXXXContractor11
1.1.8.2Routers 1…nIn packet-switched networks, a device that determines the next network point to which a packet should be forwarded toward its destination.New
Frequency BandListVolts per SecondVolts per SecondA frequency band is a small section of the spectrum of radio communication frequencies, in which channels are usually used or set aside for the same purpose. Specify if router is 2.4 GHz, 5 GHz, or dual band 2.4 & 5 GHz.New2.4 GHz5 GHz2.4 & 5 GHz (dual band)OtherxxxxxGovernment12
DRAMMBQuantityQuantityDynamic random-access memory (DRAM) is a type of random-access memory that stores each bit of data in a separate capacitor within an integrated circuitThe only reason a router needs lots of cpu and to a point memory is that is must do NAT on every packet. This means it must change the ip and then recalculate the header check sums for every single packet. The memory use is based on the number of NAT sessions which of course bit torrent has a lot of.NewxxxxContractor12
GbEthernet PortsQuantityGigabit Ethernet is a transmission technology based on the Ethernet fram format and protocol used in local area networks (LANs), providing a data rate of 1 billion bits per second (GB). It is defined as IEEE 802.3. Specify the quantuty of GbE ports.NewxxxxContractor13

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .