A15_Attachment_3_Drawings.pdf
PDF 7 MB Posted
- Attached to
- Renovate Facility for AFE, Bldg 411 Federal contract opportunity
- Solicitation number
- FA671219BA001
About this file
Attachment 3 - Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A15_Attachment_6_Bid_Opening_Entry_Authority_List_Requirements_(Bid_Opening.pdf | ||
| B411_Drawings_Revision_2_20190521_p1-12.pdf | ||
| A15_Revised_QA_Number_7.docx | DOCX document | |
| B411_Specifications_-_Rev_2_20190521.pdf | ||
| A15_Amendment_2.pdf | ||
| B411_Drawings_Revision_2_20190521_p13-End.pdf | ||
| A-16_QAs_B411.docx | DOCX document | |
| A16_Site_visit_attendees.pdf | ||
| A16_AGENDA.docx | DOCX document | |
| A15_Amendment_One__FA671219BA0010001_SF_30.pdf | ||
| A15_Attachment_3_Drawings_Rev_1_part_1_of_2.pdf | ||
| A15_Attachment_2_Specifications.pdf | ||
| WagesAttachment1_B411.docx | DOCX document | |
| A15_Solicitation_-_FA671219BA001.pdf | ||
| A15_Attachment_5_Request_for_Information.doc | DOC document | |
| A15_Attachment_4_Responsiblility_Questionair_B411.docx | DOCX document | |
| A15_Attachment_6_Entry_Authority_List_Requirements.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0' - 0"
20'-3 1/2"
LIGHT FIXTURE, SEE
ELECTRICAL DRAWINGS
PLAM BASE
CABINET, PL-1
PLAM WALL
CABINET, PL-1
SOLID SURFACE
COUNTERTOP, SS-1
SOLID SURFACE
BACKSPLASH, SS-1
ADA COMPLIANT SINK, SEE
PLUMBING DRAWING
EXISTING MASONRY
WALL TO REMAIN
EXISTING DOOR
ASSEMBLY (PAINT)
SUSPENDED CEILING
AND TRACK SYSTEM W/
2x2 CEILING TILE
13'-6" 5'-9 1/2"
A-11
TYP
A-11
TYP
3'-0" 2'-6" 3'-6" 1'-6" 3'-0"
3'-0" 2'-6" 3'-6" 1'-6" 3'-0"
/4
/4
/2
3"
2'-0"
1'-1"
1 1/2"
SHELF SUPPORTS,
5MM DIA. WITH METAL
PINS AT 1"
INCREMENTS, TYP
ADJUSTABLE PLAM SHELF
3/4" MEDIUM DENSITY
FIBERBOARD WITH PLAM
ON ALL EXPOSED
EXTERIOR SURFACES, TYP
PLAM BASE CABINET, PL-1, W/ 170
DEGREE SELF-CLOSING HINGE (MIN. 2
PER DOOR) W/ WIRE PULL HANDLE, TYP
PLAM, PL-1, SELF-CLOSING DRAWER
W/ WIRE PULL HANDLE, TYP
TOE-KICK AND 4"
HIGH RUBBER
BASE
FLOOR FINISH AS SCHEDULED
1'-11 1/4"
3/4"
3/4" SOLID SURFACE
COUNTERTOP W/ 1-1/2"
BULLNOSE, SS-1
3/4"x4" SOLID SURFACE
BACKSPLASH, SS-1
/2
PLAM WALL CABINET, PL-1, W/ 170
DEGREE SELF-CLOSING HINGE (MIN. 2
PER DOOR) W/ WIRE PULL HANDLE, TYP
SHELF SUPPORTS, 5MM
DIA. WITH METAL PINS AT
1" INCREMENTS, TYP
ADJUSTABLE PLAM SHELF
PLAM TRIM, PL-1
SUSPENDED ACOUSTICAL
CEILING TILE SYSTEM
EXISTING CMU
PARTITION
WALL PARTITION
AS SCHEDULED
/4
/4
/2
3"
2'-0"
1'-1"
3/4" MEDIUM DENSITY FIBERBOARD
WITH PLAM ON ALL EXPOSED
EXTERIOR SURFACES, TYP
PLAM BASE CABINET, PL-1, W/ 170
DEGREE SELF-CLOSING HINGE (MIN. 2
PER DOOR) W/ WIRE PULL HANDLE, TYP
PLAM, PL-1, FALSE DRAWER
PANEL, NO HANDLE
TOE-KICK AND 4"
HIGH RUBBER
BASE
FLOOR FINISH AS SCHEDULED
1'-11 1/4"
3/4" SOLID SURFACE
COUNTERTOP W/ 1-1/2"
BULLNOSE, SS-1
3/4"x4" SOLID SURFACE
BACKSPLASH, SS-1
PLAM WALL CABINET, PL-1, W/ 170
DEGREE SELF-CLOSING HINGE (MIN. 2
PER DOOR) W/ WIRE PULL HANDLE, TYP
PLAM TRIM, PL-1
2'x2' SUSPENDED
ACOUSTICAL CEILING
TILE SYSTEM
WALL PARTITION
AS SCHEDULED
EXISTING CMU
PARTITION
STAINLESS STEEL UNDER
COUNTERTOP SINK W/
MOUNTING BRACKETS
/2
WATER SHUT-OFF VALVES
FIRST FLOOR
0' - 0"
1 4
A-11
TYP
A-11
TYP
LIGHT FIXTURE, SEE
ELECTRICAL DRAWINGS
PLAM BASE
CABINET, PL-1
PLAM WALL
CABINET, PL-1
SOLID SURFACE
COUNTERTOP, SS-1
SOLID SURFACE
BACKSPLASH, SS-1
ADA COMPLIANT SINK, SEE
PLUMBING DRAWING
EXISTING MASONRY
WALL(BEYOND)
SUSPENDED CEILING
AND TRACK SYSTEM
W/ 2x2 CEILING TILE
2'-6" 3'-6" 1'-6" 2'-6"
PLUMBING CONTRACTOR TO
PROVIDE WATER SERVICE TO
EACH REFRIDGERATOR
REFRIDGERATOR NIC
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated4 /2
/2
:3 :4
P
M
RENOVATE FACILITY FOR AFE BUILDING 411Designer
Author
Checker
A-11
CASEWORK ELEVATIONS AND SECTIONS
_ 1/2" = 1'-0"
1 CASEWORK ELEVATION - OXYGEN TESTING A-107
_ 1" = 1'-0"
3 CASEWORK SECTION
_ 1" = 1'-0"
4 CASEWORK SECTION
_ 1/2" = 1'-0"
2 CASEWORK ELEVATION - BREAKROOM A-108
B
A-10
/2
19'-2" 5 5/8"
7 5/8" 8'-1" 1'-2 3/8" 9'-3"
A-123
WOMEN'S
A-102
MEN'S
A-104
F
IE
L D
V E
R
IF
Y
/4
REMOVE CMU
BULLNOSE UNITS AT
JAMBS OF OPENING,
ALIGN AND TOOTH-IN
NEW 6" CMU INFILL
A-129
NVG TESTING
A-105
JANITORS
A-103
NVG HELMET
STORAGE
A-101
VESTIBULE 'A'
A-102A VESTIBULE 'B'
A-104A
HIGH BAY
A-100
REMOVE TOILET PARTITIONS,
CLEAN AND SALVAGE
FOR REINSTALLATION
NEW PARTITION TO
MATCH EXISTING W/
NEW TOILET
ACCESSORIES
REMOVE URINAL PARTITIONS,
CLEAN AND SALVAGE
FOR REINSTALLATION
ALIGN
REMOVE TOILET
PARTITIONS, CLEAN
AND SALVAGE
FOR REINSTALLATION
EXISTING SHOWER TO
REMAIN, PROVIDE NEW
SHOWER CURTAIN AND
HOOKS
EXISTING SHOWER
TO REMAIN, PROVIDE
NEW SHOWER
CURTAIN AND HOOKS
FIRST FLOOR
0' - 0"
A-10
WOMEN'S
A-102
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING CEILING
TO REMAIN, TYP
(PAINT)
EXISTING CMU
PARTITION, TYP
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
PAINT EXISTING
DOOR AND
FRAMES, TYP
FIRST FLOOR
0' - 0"
B
WOMEN'S
A-102
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING STEEL
COLUMN (PAINT)
PAINT EXISTING
INTERIOR FACE OF
PRECAST PANEL
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
EXISTING CEILING
TO REMAIN (PAINT)
FIRST FLOOR
0' - 0"
A-10
WOMEN'S
A-102
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING STEEL
COLUMN (PAINT)
EXISTING CEILING
TO REMAIN (PAINT)
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
REMOVE TOILET
PARTITIONS, CLEAN
AND SALVAGE
FOR REINSTALLATION
EXISTING SHOWER TO
REMAIN, PROVIDE NEW
SHOWER CURTAIN
AND HOOKS
NEW PARTITION TO
MATCH EXISTING W/ NEW
TOILET ACCESSORIES
EXISTING MIRROR
TO REMAIN
FIRST FLOOR
0' - 0"
B
WOMEN'S
A-102
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
PAINT EXISTING
DOOR AND
FRAMES, TYP
NEW PARTITION TO
MATCH EXISTING
FIRST FLOOR
0' - 0"
A-10
MEN'S
A-104
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING SHOWER
TO REMAIN,
PROVIDE NEW
SHOWER CURTAIN
AND HOOKS
EXISTING CEILING
TO REMAIN (PAINT)
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
REMOVE TOILET AND
PARTITIONS, CLEAN
AND SALVAGE
FOR REINSTALLATION
REMOVE URINAL PARTITIONS, CLEAN
AND SALVAGE FOR REINSTALLATION
PAINT EXISTING
INTERIOR FACE OF
PRECAST PANEL
FIRST FLOOR
0' - 0"
MEN'S
A-104
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
PAINT EXISTING
INTERIOR FACE OF
PRECAST PANEL
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
EXISTING CEILING
TO REMAIN (PAINT)
REMOVE TOILET PARTITIONS,
CLEAN AND SALVAGE
FOR REINSTALLATION
FIRST FLOOR
0' - 0"
A-10
MEN'S
A-104
VESTIBULE 'B'
A-104A
REMOVE CMU
BULLNOSE UNITS AT
JAMBS OF OPENING,
ALIGN AND TOOTH-IN
NEW 6" CMU INFILL
(PAINT)
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING CEILING
TO REMAIN (PAINT)
EXISTING CMU
PARTITION, TYP
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
PAINT EXISTING
DOOR AND
FRAMES, TYP
NEW GWB BOARD
CEILING (PAINT)
FIRST FLOOR
0' - 0"
MEN'S
A-104
STAINLESS STEEL
WAINSCOT TO REMAIN W/A
(NO WALL BASE), TYPICAL
PT-1, 6" BASE
(AT ALL PT-1
LOCATIONS)
EXISTING CEILING
TO REMAIN (PAINT)
PAINT EXISTING
CMU PARTITIONS IN
TOILET ROOMS AND
VESTIBULES, TYP
PAINT EXISTING
DOOR AND
FRAMES, TYP
REMOVE URINAL
PARTITIONS, CLEAN
AND SALVAGE
FOR REINSTALLATION
B
A-10
12"x24" PORCELIN TILE (PT-1)
1/2 RUNNING BOND PATTERN
(SEE FINISH LEGEND AND SCHEDULES
ON DRAWING A-7 AND A-13)
WOMEN'S
A-102
MEN'S
A-104
FINISHED WALL SURFACE
6" PORCELIN TILE BASE (CUT
12"x24" TILE, EXPOSE FINISH EDGE
FOR TILE BASE ONLY, INSTALL CUT
EDGE BELOW FINISH FLOOR)
MORTAR BED
12"x24" PORCELIN TILE
(INSTALL TILE FLOOR AFTER
TILE BASE INSTALLATION)6
FINISHED EDGE OF TILE
GROUT
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated4 /2
/2
:3 :4
P
M
RENOVATE FACILITY FOR AFE BUILDING 411Designer
Author
Checker
A-12
ENLARGED TOILET ROOM PLANS AND
ELEVATIONS
_ 3/8" = 1'-0"
1 ENLARGED TOILET ROOM PLAN
_ 3/8" = 1'-0"
3 ELEVATION - WOMENS A-114
_ 3/8" = 1'-0"
4 ELEVATION - WOMENS A-114
_ 3/8" = 1'-0"
5 ELEVATION - WOMENS A-114
_ 3/8" = 1'-0"
6 ELEVATION - WOMENS A-114
_ 3/8" = 1'-0"
9 ELEVATION - MENS A-111
_ 3/8" = 1'-0"
8 ELEVATION - MENS A-111
_ 3/8" = 1'-0"
7 ELEVATION - MENS A-111
_ 3/8" = 1'-0"
10 ELEVATION - MENS A-111
N _ 3/8" = 1'-0"
2 ENLARGED FINISH FLOOR PLAN
PORCELIN TILE BASE
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
/2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-1
STRUCTURAL GENERAL NOTES AND
ABBREVIATIONS
A. DESIGN CRITERIA
1. CODES: ALL STRUCTURES HAVE BEEN DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:
a. PENNSYLVANIA BUILDING CODE (UNIFORM CONSTRUCTION CODE)
b. INTERNATIONAL BUILDING CODE 2015
2. DESIGN STANDARDS: ALL STRUCTURES HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
FOLLOWING DESIGN STANDARDS:
a. ACI 318-14 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"
b. ACI 530-13 "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES."
c. AISC STEEL CONSTRUCTION MANUAL 14TH EDITION: ALLOWABLE STRESS DESIGN.
d. ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES."
e. AWS D1.1-04 "AWS STRUCTURAL WELDING CODE."
f. SDI DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS AND ROOF DECKS - NO.31
B. DESIGN LOADS
1. LIVE LOADS
MEZZANINE STORAGE LEVEL ...................................... 125 PSF
STAIRS ............................................................................. 100 PSF
2. SEISMIC LOADS
SITE CLASS ................................................................... D
SPECTRAL RESPONSE COEFFICIENT:
Ss ....................................................................... 0.112g Si ........................................................................ 0.053g SDS .................................................................... 0.119g SDI ...................................................................... 0.085g
IMPORTANCE FACTOR Ie ............................................. 1.0
SEISMIC DESIGN CATEGORY ...................................... B
C. GENERAL CONDITIONS
1. ALL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL,
FIRE PROTECTION, ELECTRICAL, HEATING AND VENTILATING, AND PLUMBING DRAWINGS
AND SPECIFICATIONS.
2. SEE ARCHITECTURAL, FIRE PROTECTION, HEATING AND VENTILATING, ELECTRICAL AN
PLUMBING DRAWINGS FOR REGLETS, PIPE SLEEVES, CONDUITS OR OTHER ITEMS TO BE
EMBEDDED OR PASSED THROUGH CONCRETE.
3. THE CONTRACTOR SHALL REVIEW AND VERIFY DIMENSIONS SHOWN IN ALL PLANS AND
REVIEW ALL FIELD CONDITIONS THAT MAY AFFECT THE INSTALLATION OF THE
STRUCTURES. SHOULD DISCREPANCIES APPEAR, THE CONTRACTOR SHALL NOTIFY
THE ENGINEER IN WRITING TO OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING
THE WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY DURING
CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR
STABILITY UNDER THE FINAL CONFIGURATION ONLY.
5. SPECIAL INSPECTION SHALL BE CONDUCTED IN ACCORDANCE WITH THE REQUIREMENTS SET
FORTH IN CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE, (IBC).
D. FOUNDATIONS
1. ALL NEW FOOTINGS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 4 KSF.
2. SEE SPECIFICATIONS FOR FILL, BACKFILL AND COMPACTION REQUIREMENTS.
3. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF ALL TEMPORARY SHORING AND FOR THE
STABILITY OF ALL TEMPORARY EARTH CUTS AND SLOPES.
E. CAST IN PLACE CONCRETE
1. REINFORCED CONCRETE SHALL COMPLY WITH ACI 318.
2. MINIMUM CONCRETE STRENGTH AT 28 DAYS:
STRUCTURAL CONCRETE, UNO: ............................................................... f'c = 4000 PSI
3. REINFORCING STEEL SHALL BE NEW BILLET STEEL CONFORMING TO ASTM
SPECIFICATION A615 GRADE 60.
4. REINFORCING STEEL FABRICATION SHALL BE IN COMPLIANCE WITH THE CRSI MANUAL
OF STANDARD PRACTICE. PROVIDE ACI SEISMIC HOOKS FOR ALL BEAM STIRRUPS
AND COLUMN TIES.
5. REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM CLEAR CONCRETE
COVER UNO:
a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: ............... 3"
b. CONCRETE SURFACES IN CONTACT WITH SOIL, WATER OR
EXPOSED TO WEATHER ................................................................................................ 2"
c. CONCRETE SURFACES NOT IN CONTACT WITH SOIL, WATER OR
EXPOSED TO WEATHER:
BEAMS AND COLUMNS (PRINCIPAL REINFORCEMENT TIES AND
STIRRUPS): ................................................................................... 11/2"
WALLS AND TOP AND BOTTOM OF SLABS: ........................................................ 1"
6. SPLICED BARS SHALL HAVE A MINIMUM LAP OF CLASS B TENSION LAP SPLICE PER
SCHEDULE BELOW, UNO.
CLASS B TENSION LAP SPLICE LENGTHS TENSION DEVELOPMENT LENGTHS
IN WALLS AND SLABS (INCHES) IN WALLS AND SLABS (INCHES)
NOTES:
a. MINIMUM BAR SPACING = 6" OC
b. MINIMUM CONCRETE COVER = 1"
c. HORIZONTAL BAR IS CONSIDERED A TOP BAR IF MORE THAN 12" OF FRESH
CONCRETE IS CAST DIRECTLY BELOW THE BAR.
7. CONSTRUCTION JOINTS SHALL NOT BE PLACED AT LOCATIONS OTHER THAN THOSE
SHOWN ON THE DRAWINGS WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ENGINEER.
8. ALL EXPOSED CORNERS OF CONCRETE TO HAVE 3/4" MINIMUM CHAMFER, UNO.
9. SEE ARCHITECTURAL, MECHANICAL, HVAC, AND ELECTRICAL DRAWINGS FOR SIZE AND
LOCATION OF EQUIPMENT PADS. COORDINATE FINAL SIZE, LOCATION AND ANCHOR
BOLTS WITH APPROVED EQUIPMENT SUBMITTALS AND CONTRACTOR.
10. PROVIDE ADDITIONAL BARS IN WALLS AND SLABS AS SHOWN IN TYPICAL DETAILS.
11. EPOXY GROUT DOWELS INTO EXISTING CONCRETE WITH HILTI HIT HY200 ADHESIVE OR MINIMUM
EMBEDMENT SHALL BE 5" FOR #4 AND 6" FOR #5 DOWELS, UNO.
12. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
STRUCTURAL GENERAL NOTES: STRUCTURAL ABBREVIATIONS:
F. STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
AISC STEEL CONSTRUCTION MANUAL 14TH EDITION.
2. MATERIALS:
A. BEAMS, COLUMNS AND STRUCTURAL TEES (W SHAPES): ASTM A992 (FY 50 KSI)
B. S SHAPES, CHANNELS, ANGLES AND PLATES: ASTM A36
C. STRUCTURAL TUBES: ASTM A500 GRADE B
D. STRUCTURAL PIPES: ASTM A501 OR ASTM A53, TYPE E OR S, GRADE B
3. CONNECTIONS:
A. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING
CODE - STEEL". WELDING FILLER METAL SHALL BE AWS A5.1 OR A5.5 E70XX
LOW HYDROGEN ELECTRODES. WELDERS SHALL BE AWS CERTIFIED. SUBMIT
COPY OF ALL CERTIFICATIONS TO THE ENGINEER. SURFACES TO BE WELDED
SHALL BE WIRE BRUSHED CLEAN BEFORE WELDING.
B. ALL FIELD CONNECTIONS SHALL USE BOLTS, UNO. ALL SHOP CONNECTIONS SHALL BE
WELDED, UNO. ALL SHOP AND FIELD INSTALLED BOLTS SHALL BE 5/8"∅ ASTM A-325
TYPE N BOLTS IN STANDARD HOLES AND SNUG TIGHT, UNO.
C. ALL BOLTED CONNECTIONS 2 BOLTS MINIMUM, UNO.
D. FABRICATE AND ERECT ALL STRUCTURAL STEEL WITH RESIDUAL MILL CAMBER
UPWARDS.
E. MACHINE BOLTS SHALL BE ASTM A307.
4. ANCHOR RODS SHALL BE ASTM F1554 GRADE 36, UNO.
5. ALL STRUCTURAL STEEL MEMBERS SUCH AS BRICK SUPPORT ANGLES, LINTELS IN
EXTERIOR WALLS & ALL CONNECTION MATERIAL OF MEMBERS EXPOSED TO WEATHER
SHALL BE HOT DIP GALVANIZED, UNO.
6. ALL MAIN MEMBERS AND SECONDARY MEMBERS SUCH AS ANGLES, PLATES, ETC NOT
EXPOSED TO WEATHER, EXCEPT AS MENTIONED IN NOTE 6, SHALL BE PRIME PAINTED
WITH A MINIMUM DRY FILM THICKNESS OF 2.5 MILS. SURFACES IN CONTACT WITH
CONCRETE OR GROUT, SURFACES TO BE WELDED, GALVANIZED OR RECEIVE SPRAY ON
FIREPROOFING AND FAYING SURFACES OF SLIP CRITICAL CONNECTIONS SHALL NOT BE PRIME
PAINTED.
7. ENDS OF ALL HOLLOW STRUCTURAL SECTIONS (HSS) AND STRUCTURAL PIPE SHALL BE
CLOSED WITH 1/4" PLATE AND SEAL WELDED, UNO.
8. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
G. STEEL DECK NOTES
1. STEEL DECK SHALL CONFORM TO ASTM A653 AND STEEL DECK INSTITUTE.
2. THE MINIMUM YIELD STRENGTH OF METAL ROOF DECK SHALL BE 33 KSI.
THE MINIMUM YIELD STRENGTH OF COMPOSITE METAL FLOOR DECK SHALL BE 50 KSI.
3. STEEL DECK SHALL BE INSTALLED IN NOT LESS THAN THREE SPAN LENGTHS EXCEPT
WHERE STEEL LAYOUT DOES NOT PERMIT.
4. STEEL FLOOR DECK F1 SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES:
- 1 1/2"-20 GA NON-COMPOSITE FLOOR DECK
- GALVANIZED COATING
- IP = 0.222 IN4//FT
- IN = 0.186 IN4//FT
- SP = 0.231 IN3//FT
- SN = 0.224 IN3//FT
5. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING CODE -
SHEET STEEL". WELDING FILLER MATERIAL SHALL BE AWS A5.1 OR A5.5 E60XX LOW
HYDROGEN ELECTRODES. WELDERS SHALL BE AWS CERTIFIED. SUBMIT COPY OF
ALL CERTIFICATIONS TO THE ENGINEER.
6. SCREWS FOR DECK ATTACHMENT SHALL BE #10 TEK FASTENERS WHERE SPECIFIED.
7. ATTACH STEEL DECK TO ALL SUPPORTS WITH 5/8" DIA PUDDLE WELDS AND
AT PANEL SEAMS WITH #10 SCREWS. SEE NOTES BELOW FOR DECK ATTACHMENT:
9. EDGE OF DECK AT OPENING SHALL BE AT EDGE OF FRAMING ANGLE, UNO.
10. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
f'c=4000 PSI
BAR SIZE
TOP BARS
OTHER BARS
OTHER BARS
f'c=4000 PSI
BAR SIZE
TOP BARS
DECK TYPE 1 1/2" NON-COMP FLOOR DECK (F1)
AT PERPENDICULAR SUPPORTS
(5/8" DIA WELDS)
AT PARALLEL EDGE SUPPORTS
(5/8" DIA WELDS)
AT SIDE LAPS
(#10 SCREWS)
12" OC
12" OC
12" MAX OC
AB
ABV
ADDL
AFF
AFG
AGG
AL
ALT
APPROX
ARND
ASSY
ASTM
B TO B
BITUM
BF
BLDG
BLKG
BM
BOD
BOT
BRG
BS
BSMT
CHAM
CIP
CIRC
CJ
CL
CLJ
CLR
CMU
COL
COMP
CONC
CONN
CONST
CONT
CONTR
CRS
CTG
CTR
CU FT
DEG
DET
DIA
DIAG
DIM(S)
DL
DO
DWG
DWL(S)
EA
EB
EE
EF
EL
ENGR
EOD
EOS
EQ
ES
EW
EXP JT
EXIST
EXT
f'c f'm
FAB
FD
FDN
FF
FIN
FL
FRP
FS
FT
FTG
FV
GA
GALV
GR
GRT
GRTG
HAS
HCA
HOR, H
HP
HR
IAW
ID
IF
IN
INFO
INSUL
INT
INV
ISOL
JT
JT FLR
L
LAD
ABBREVIATION NOTES:
1. ABBREVIATIONS AND DESIGNATIONS FOR STEEL MEMBERS MAY BE FOUND IN THE
CURRENT MANUAL OF STEEL CONSTRUCTION BY AISC
2. ABBREVIATIONS OF TECHNICAL SOCIETIES AND TRADE ASSOCIATIONS MAY BE
FOUND IN THE SPECIFICATIONS.
3. WELDING SYMBOLS AND ABBREVIATIONS MAY BE FOUND IN AWS 2.4.
AND
AT
DEGREES
DIAMETER
NUMBER
ANCHOR BOLT
ABOVE
ADDITIONAL
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AGGREGATE
ALUMINUM
ALTERNATE(ING)
APPROXIMATELY
AROUND
ASSEMBLY
AMERICAN SOCIETY FOR
TESTING MATERIALS
BACK TO BACK
BITUMINOUS
BOTTOM FACE
BUILDING
BLOCKING
BEAM
BOTTOM OF DECKING
BOTTOM
BEARING
BOTH SIDES
BASEMENT
CHAMFER
CAST IN PLACE
CIRCUMFERENTIAL
CONSTRUCTION JOINT
CENTERLINE
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNITS
COLUMN
COMPRESSIBLE
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COURSE(S)
COATING
CENTER(ED)
CUBIC FEET
DEGREES
DETAIL
DIAMETER
DIAGONAL
DIMENSION(S)
DEAD LOAD
DITTO
DRAWING
DOWEL(S)
EACH
EXPANSION BOLT
EACH END
EACH FACE
ELEVATION
ENGINEER
EDGE OF DECK
EDGE OF SLAB
EQUAL(LY)
EACH SIDE
EACH WAY
EXPANSION JOINT
EXISTING
EXTERIOR
CONCRETE COMPRESSION STRENGTH
MASONRY COMPRESSIVE STRENGTH
FABRICATE(D)(OR)
FLOOR DRAIN
FOUNDATION
FAR FACE
FINISH(ED)
FLOOR
FIBERGLASS REINFORCED PLASTIC
FAR SIDE
FEET/FOOT
FOOTING
FIELD VERIFY
GAGE
GALVANIZED
GRADE
GROUT
GRATING
HEADED ANCHOR STUD
HEADED CONCRETE ANCHOR
HORIZONTAL
HIGH POINT
HANDRAIL
IN ACCORDANCE WITH
INSIDE DIAMETER
INSIDE FACE
INCH
INFORMATION
INSULATION
INTERIOR
INVERT
ISOLATOR, ISOLATION
JOINT
JOINT FILLER
STRUCTURAL ANGLE
LADDER
LB(S)
LF
LG
LLH
LLV
LNTL
LOC
LONG
LP
LT
LW
MAS
MATL
MAX
MB
MCJ
MECH
MEMB
MFR
MIN
MISC
MO
MTL
NF
NIC
NOM
NS
NSG
NTS
NW
OC
OD
OF
OPNG(S)
OPP
OPP HD
OPT
OVS
PCF
PJF
PL
PNL
PC
PRMLD
PROJ
PSF
PSI
PVC
PVMT
QUAN
R
RAD
RD
REF
REINF
REQD
REV
RFG
RLG
RO
RT
SECT
SHT
SIM
SLNT
SLV
SOG
SP
SPEC(S)
SQ
SST
STD
STIF
STIR
STL
STRUC
SYM
SWP
T T/ T&B
TECH
TF
THD
THK
THRU
TOC
TOF
TOJ
TOM
TOPG
TOS
TOW
TYP
UNO
UT
VB
VERT, V
VIF
W/ W/O
WEA
WP
WPG
WS
WWF
POUND(S)
LINEAL FEET
LONG
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LINTEL
LOCATION/LOCATED
LONGITUDINAL
LOW POINT
LEFT
LIGHT WEIGHT
MASONRY
MATERIAL
MAXIMUM
MACHINE BOLT
MASONRY CONTROL JOINT
MECHANICAL
MEMBRANE
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
METAL
NEAR FACE
NOT IN CONTRACT
NOMINAL
NEAR SIDE
NON-SHRINK GROUT
NOT TO SCALE
NORMAL WEIGHT
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OPENING(S)
OPPOSITE
OPPOSITE HAND
OPTIONAL
OVERSIZED
POUNDS PER CUBIC FEET
PREMOLDED JOINT FILLER
PLATE
PANEL
PRECAST
PREMOLDED
PROJECTION
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POLYVINYL CHLORIDE
PAVEMENT
QUANTITY
RISER(S)
RADIUS
ROOF DRAIN
REFERENCE/REFER
REINFORCE(D, ING)
REQUIRED
REVISION
ROOFING
RAILING
ROUGH OPENING
RIGHT
SECTION
SHEET
SIMILAR
SEALANT
SLEEVE
SLAB ON GRADE
SPACE(S)(ED)
SPECIFICATION(S)
SQUARE
STAINLESS STEEL
STANDARD
STIFFENER
STIRRUP
STEEL
STRUCTURE(S)(URAL)
SYMMETRICAL
SLAB WORK POINT
TREAD(S)
TOP OF
TOP AND BOTTOM
TECHNICAL
TOP FACE
THREADED
THICK, THICKNESS
THROUGH
TOP OF CONCRETE
TOP OF FOOTING
TOP OF JOIST
TOP OF MASONRY
TOPPING
TOP OF STEEL
TOP OF WALL
TYPICAL
UNLESS NOTED OTHERWISE
ULTRASONIC TESTING
VAPOR BARRIER
VERTICAL
VERIFY IN FIELD
WITH
WITHOUT
WEDGE TYPE EXPANSION ANCHOR
WORKING POINT
WATERPROOFING
WATERSTOP
WELDED WIRE FABRIC
A B C
D E F
19' - 7" 30' - 0" 30' - 0" 30' - 0" 21' - 4"
(TYP)
9' - 2" +/- 2' - 10" +/-
EXIST 8" CMU WALL
TO BE REMOVED
(TYP)
APPROXIMATE LIMITS
OF SLAB DEMO
(TYP)
(TYP)
9' - 2" +/-
/8
/8
/8
/8
/8
2' - 0"
(TYP)
4' - 10" +/-
EXIST WALL FOOTING
REMOVE ONLY WHERE REQD
(T Y
P
4' - 7" +/-
/2
2' - 8"
11' - 4" 3' - 3" 5' - 0" 5' - 0" 10' - 0" 10' - 0" 5' - 0" 6' - 6" 18' - 6" 5' - 0" 5' - 0" 20' - 0" 5' - 0" 5' - 3 3/8" 11' - 0 5/8" 4' - 4" 8"
5' - 1" +/- 5' - 1" +/-
5' - 11" +/-
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
3/16" = 1'-0"0 /2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-2
DEMOLITION PLAN
3/16" = 1'-0"
EXISTING FLOOR SLAB DEMOLITION PLAN
N
A B C
D E F
19' - 7" 30' - 0" 30' - 0" 30' - 0" 21' - 4"
/8
/8
/8
/8
/8
2' - 0"
5'-6" SQ x 1'-2" THICK
CONC FOOTING, REINF
W/ #4@6 EW T&B (TYP @ ALL
INTERIOR COLUMNS, UNO)
5'-6" x 2'-0" x 1'-6" THICK
CONC FOOTING, REINF
W/ #4@6 EW T&B (TYP @ ALL
EXTERIOR COLUMNS, UNO)
EXIST COL FTG
(TYP)
EXIST WALL FTG
(TYP)
EXIST 12" CMU FDN WALL
(TYP)
EXIST COL PIER
(TYP) HSS 6x6x1/2 POST
(TYP) AT 23 LOCATIONS
S-6
B
S-6
A
(TYP)
(TYP)
UNO
2' - 9"
UNO
2' - 9"
REMOVE PORTION OF EXIST FTG
FLUSH W/ INSIDE FACE OF CMU WALL
TO ACCOMODATE NEW COL FTG
(DO NOT REMOVE ANY PORTION OF
EXIST COLUMN FOOTING) (TYP)
EXIST 12" CMU FDN WALL
(TYP)
S-6
/2
2' - 8"
11' - 4" 3' - 3" 5' - 0" 5' - 0" 10' - 0" 10' - 0" 5' - 0" 6' - 6" 18' - 6" 5' - 0" 5' - 0" 20' - 0" 5' - 0" 5' - 3 3/8" 11' - 0 5/8" 4' - 4" 8"
6'-6" SQ x 1'-4" THICK
CONC FOOTING, REINF
W/ #5@6 EW T&B
6'-0" x 2'-0" x 1'-6" THICK
CONC FOOTING, REINF
W/ #4@6 EW T&B
7'-0" x 2'-0" x 3'-3" THICK
CONC FOOTING, REINF
W/ #4@6 EW T&B
7'-0" x 2'-0" x 3'-3" THICK
CONC FOOTING, REINF
W/ #4@6 EW T&B
3' - 0" 3' - 0"
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
3/16" = 1'-0"0 /2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-3
FOUNDATION PLAN
3/16" = 1'-0"
FOUNDATION PLAN
A B C
/2
D E F
19' - 7" 30' - 0" 30' - 0" 30' - 0" 21' - 4"
A B C D E F
4.9
F1
/8
/8
/8
/8
/8
11"
HSS 6x6x1/2 POST
(TYP)
NOTE: SEE ARCH DWGS FOR
NEW STAIRS UP TO
MEZZANINE.
S-6
APPROXIMATE LIMITS
OF SLAB REPLACEMENT
(TYP) SEE NOTE 1
(TYP)
9' - 2" +/-
(TYP)
4' - 10" +/-
(T Y
P
12' - 2" +/- 3' - 10" +/- 7' - 3" +/-
(TYP)
9' - 2" +/-
(T Y
P
2' - 8"
11' - 4" 3' - 3" 5' - 0" 5' - 0" 10' - 0" 10' - 0" 5' - 0" 6' - 6" 18' - 6" 5' - 0" 5' - 0" 20' - 0" 5' - 0" 5' - 3 3/8" 11' - 0 5/8" 4' - 4" 8"
5' - 11" +/-
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
3/16" = 1'-0"0 /2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-4
FIRST FLOOR PLAN
3/16" = 1'-0"
FIRST FLOOR PLAN
N
NOTES:
1. NEW CONC SLAB TO HAVE #4@12 REINFORCMENT EW.
E/W BARS TO BE LOCATED ABOVE N/S BARS (TYP,UNO)
A B C
D E F
19' - 7" 30' - 0" 30' - 0" 30' - 0" 21' - 4"
W12X50W12X50 W12X87 W12X50 W12X50
W
X
W
X
W
X
W
X
W12X50 W12X50 W12X50 W12X50 W12X50 W18X106
W
X
W10X30
W10X30
W10X30
W10X30
W10X30
W10X30
W10X30
W10X30
W10X30
W
X
W
X
C10X30
W
X
W
X
W
X
C10X30
W
X
W
X
W
X
C10X30
W
X
W
X
W
X
C10X30
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
C
X
W10X30
C
X 0W10X30
W
X
W10X30
S-6
S-6
(TYP)
1' - 6"
/8
/8
S
P
/8
S
P
/8
L4x4x3/8 (TYP)
S-6
Sim
S-6
Sim
(T Y
P
S-6
C
S-6
S-6
Sim
S-6
Sim
2' - 0" 4' - 8"
6 1/4"
GUARDRAIL
(TYP)
3 1/2" CONC SLAB W/
WWF 4x4 - W2.9xW2.9
ON 1 1/2" MTL DECK
(DECK F1) TOTAL DEPTH = 5"
/2
3' - 3"
5' - 0"
S-6
W
X
4' - 8"
3 1/2" CONC SLAB W/
WWF 4x4 - W2.9xW2.9
ON 1 1/2" MTL DECK
(DECK F1) TOTAL DEPTH = 5"
S-7
A
S-7
B
S-7
D
S-7
C
(TYP @ W10)
(TYP @ W12)
7 SP @ 5'-0" = 35' - 0" 6' - 6" 3' - 6" 10 SP @ 5'-0" = 50' - 0" 5' - 3 3/8" 16' - 0 5/8"
ADDL BARS #4 x 6'-0" LONG @ 12" OC.
CENTER ON W12 BM W/ 1" CLEAR
FROM TOP OF SLAB
S-7
D Sim
S-7
C Sim
S-7
D Sim
(NOTE 1)
NOTES:
1. PROVIDE 3/4" MAX CAMBER IN BEAM.
2. = MOMENT CONNECTION
HVAC EQUIP PAD
SEE DTL G/SD-1.
COORDINATE SIZE &
LOCATION W/ EQUIP MFR
OPNGS IN MEZZANINE
FLOOR SLAB & EQUIPMENT PAD.
SEE HVAC DWGS. COORDINATE
SIZE & LOCATION W/ EQUIPMENT MFR.
PROVIDE FORMS FOR OPNGS. DO NOT
CUT DECK BEFORE CONCRETE HARDENS
STAIRS, SEE ARCH DWGS
STAIRS, SEE ARCH DWGS
S-7
G Sim
(TYP, UNO)
S-7
D Sim
S-7
G Sim
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
3/16" = 1'-0"0 /2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-5
MEZZANINE PLAN
3/16" = 1'-0"
MEZZANINE PLAN
S-6
VARIES, SEE PLAN VARIES, SEE PLAN
CL
V A
R
IE
S S
E E
P L
A N
V A
R
IE
S S
E E
P L
A N
C L
NEW CONC FTG
VARIES, SEE PLAN VARIES, SEE PLAN
CL
C L
REMOVE PORTION OF EXIST FTG
FLUSH W/ INSIDE FACE OF CMU WALL
TO ACCOMODATE NEW COL FTG
(DO NOT REMOVE ANY PORTION OF
EXIST COLUMN FOOTINGS) CONSULT
ENGINEER IF SPACE DOES NOT
ALLOW FOR REQD FOOTING SIZE &
LOCATION SHOWN ON DWGS
EXIST 12" CMU WALL
S-6
FIRST FLOOR
0.00
HSS6x6
VARIES
S-6
6" COMPACTED FILL
1/2" PJF & SEALANT
ALL AROUND EXIST 6" CONC SLAB
(4) 5/8" DIA AB'S W/ 6" MIN EMBED
SEE NOTE 2
INTERIOR
FOUNDATION
-1.33
(REMOVE & REPLACE EXIST FLOOR SLAB)
9' - 2" +/- (TYP, UNO)
V A
R
IE
S
REINF VARIES, SEE PLAN
VARIES
N S
G
C L
DWLS #4@12, EMBED 4 1/2"
W/ EPOXY ADHESIVE (TYP)
#4@12
EW
(TYP)
LAP SPLICE
MEZZANINE
12.00
POUR STOP
L5x5x1/4 CONT
L4x4
EXIST STL COL
C10
W10
W12
POUR STOP
L5x5x1/4 @
3 SIDES OF COL
1"
PL 1/4x5x5
3/16
3/16
3/16
3/16
3/16
1" GAP
COPE FLANGES OF W12 TO SUIT
MEZZANINE
12.00
POUR STOP
L5x5x1/4 CONT
L4x4
W12
3 1/2" CONC SLAB
ON 1 1/2" STL DECK
W10
HSS6x6
1" GAP
3/16
MEZZANINE
12.00
POUR STOP
L5x5x1/4 CONT
W10W12
GUARDRAIL
6 5/8"
5/8" DIA x 1'-6" LG DEFORMED BAR ANCHOR
(INSTALL IN FIELD) PROVIDE 2 @ 6" OC
AT EACH RAIL POST
C
S-6
S-6
(TYP)
1"
C10
W
L x
W
L x
L x x /8
L x x /8
W12W12
HSS6x6
(TYP)
W
PER PLAN PER PLAN
L x x /8
L x x /8
LOCATE TO SUIT EXIST
FIRST FLOOR
0.00
EXTERIOR
FOUNDATION
-3.33
HSS6x6 W/
3/4" BASE PL
6" COMPACTED FILL
1/2" PJF ALL
AROUND
(4) 5/8" DIA AB'S W/ 6" MIN EMBED
SEE NOTE 2
EXIST WALL FTG
EXIST 12" CMU FDN WALL
EXIST CONC FILL
S-6
Sim
5' - 2"
COMPACTED FILL
V A
R
IE
S
V A
R
IE
S
ROUGHEN (TYP)
BOND BREAKER
3' - 10" 1' - 4"
REINF VARIES, SEE PLAN
8"
N S
G
DWLS #4@12, EMBED 4 1/2"
W/ EPOXY ADHESIVE
#4@12 EW
C L
LAP SPLICE
6" 6"
4 1/2"4 1/2"
/2
/2
3/16
HSS6x6
PL 1x12x1'-0" W/
(4) 15/16" DIA
HOLES FOR 5/8"
DIA AB'S (TYP)
SEE NOTE 1
NOTES:
1. PROVIDE 1 1/8" THICK PLATE AT
COLUMN E2-4.2
FIRST FLOOR
0.00
INTERIOR
FOUNDATION
-1.33
EXIST 6" CONC SLAB
6" CONC SLAB
INFILL
(REMOVE & REPLACE EXIST FLOOR SLAB)
2' - 10" +/-
EXIST 8" CMU WALL
DEMOLISH DOWN TO TOP OF FTG
EXIST FTG TO REMAIN
(DEMOLISH AT ONE LOCATION
WHERE NOTED ON PLAN)
COMPACTED
FILL
2' - 0"
ROUGHEN (TYP)
LAP SPLICE
DWLS #4@12, EMBED 4 1/2"
W/ EPOXY ADHESIVE (TYP)
#4@12
C L
MEZZANINE
12.00
POUR STOP
L5x5x1/4 CONT
W10
W18
GUARDRAIL
6 5/8"
5/8" DIA x 1'-6" LG DEFORMED BAR ANCHOR
(INSTALL IN FIELD) PROVIDE 2 @ 6" OC
AT EACH RAIL POST
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated0 /2
/2
:4
:1
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-6
SECTIONS AND DETAILS
3/4" = 1'-0"S-3
A INTERIOR FOOTING DETAIL
3/4" = 1'-0"S-3
B EXTERIOR FOOTING DETAIL
1" = 1'-0"S-6
2 SECTION
1" = 1'-0"S-5
5 SECTION
1" = 1'-0"S-5
6 SECTION
1" = 1'-0"S-5
7 SECTION
3/4" = 1'-0"S-5
C DETAIL
1" = 1'-0"S-6
3 SECTION
3" = 1'-0"S-6
4 SECTION
1" = 1'-0"S-3
1 SECTION
1" = 1'-0"S-5
8 SECTION
NOTES:
2. ANCHOR BOLTS TO BE 5/8" DIA W/ NUT & WASHER AT TOP
AND NUT & 3"x3" PLATE WASHER AT BOTTOM. PROVIDE 9"
EMBEDMENT INTO FOOTING.
/2
(TYP)
2"
1/4"
5/8" DIA BOLTS
(TYP)
PL 1/4x6 1/2x9 1/2
W10
PL 1/4x3x6
3/16
3/16
(TYP)
3/16
3/16
3/16
(TYP) 3
SIDES
HSS6x6
CL
PL 1/4x6 1/2x3 1/4
(T Y
P
/2
(T Y
P
(TYP)
2"
1/4"
5/8" DIA BOLTS
(TYP)
PL 1/4x8x9 1/2
W12
PL 1/4x3x9 W/
(3) 5/8" DIA BOLTS
3/16
3/16
(TYP)
3/16
3/16
(TYP) 3
SIDES
HSS6x6
CL
PL 1/4x8x3 1/4
5/8" DIA BOLTS
(TYP)
W12
1/4
HSS6x6
PL 1 1/8x8x11
(T Y
P
(T Y
P
3 1/4" 6 1/4"
/4
/4
PL 1/4
W10
HSS6x6 BELOW
1 1/4"CL
C L
(T Y
P
(T Y
P
3 1/4" 6 1/4"
PL 1/4
W12
HSS6x6 BELOW
1 1/4"
CL
C L
5 1/2" 5 1/2"
PL 1 1/8
W12
HSS6x6 BELOW
CL
C L
4 1/4"4 1/4"
TYPICAL BEAM-TO-BEAM SHEAR CONNECTIONS
SIZE
VERT LOAD
(ASD)
MIN # OF
BOLT ROWS
C10x30
W10x30
10K
15K
P E
R T
A B
L E
O
F R
O W
S O
F B
O L
T S
MIN 1/4" THICK
V
NOTE:
1. ALL BEAM AND GIRDER CONNECTIONS TO BE
DESIGNED BY FABRICATOR'S ENGINEER. SEE
SCHEDULE FOR CONNECTION LOADS.
W BM
TYPICAL BEAM-TO-COLUMN SHEAR CONNECTIONS
SIZE
VERT LOAD
(ASD)
MIN # OF
BOLT ROWS
W10x30
W12x50
(TYP, UNO)
W18x106
15K
24K
40K
MIN 1/4" THICK
NOTE:
1. ALL BEAM AND GIRDER CONNECTIONS TO BE
DESIGNED BY FABRICATOR'S ENGINEER. SEE
SCHEDULE FOR CONNECTION LOADS.
W BM
HSS6x6
8 1/2" 8 1/2"
/4
/4
PL 1 1/2
W12
HSS6x6 BELOW
CL
C L
W10
END PL 5/8
PL 5/8
3" 4 1/4" 4 1/4" 3"
5/8" DIA BOLTS
(TYP)
W12
1/4
HSS6x6
PL 1 1/2x8 1/2x1'-5"
W10
END PL
HSS6x6
W12
W10
PL 1 1/2
PL 5/8PL 5/8
1/4 1/4 6
1/4 6
1/4
AT T&B
FLANGES
NOTE: SEE SECT 4/-
FOR PARTS NOT NOTED
5/8" DIA BOLTS W/ NUT (TYP)
IN STD HOLES
(T Y
P
1/4
EA FLANGE
T&B
5/8" DIA BOLTS
(TYP)
W12
1/4
HSS6x6
PL 1/2x8x11"
W10 W12
HSS6x6
STIF PL 3/8 AT INNER
FACE WHERE NO
FRAMING BEAM EXISTS
5 1/2" 5 1/2"
PL 1/2
W12
HSS6x6 BELOW
CL
C L
4 1/4"4 1/4"
3/16
3/16
TYP @ WEB &
FLANGES
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
3" = 1'-0"0 /2
/2
:4
:2
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
S-7
STEEL FRAMING DETAILS
_ 3" = 1'-0"
1 SECTION - MOMENT CONNECTION
_ 3" = 1'-0"
2 SECTION - MOMENT CONNECTION
_ 3" = 1'-0"
3 SECTION - MOMENT CONNECTION
3" = 1'-0"S-5
A DETAIL - MOMENT CONNECTION
3" = 1'-0"S-5
B DETAIL - MOMENT CONNECTION
3" = 1'-0"S-5
C DETAIL - MOMENT CONNECTION
1 1
2 2
3 3
_ 3" = 1'-0"
E DETAIL - SHEAR CONNECTIONS - BEAM TO BEAM
_ 3" = 1'-0"
F DETAIL - SHEAR CONNECTIONS - BEAM TO COLUMN
3" = 1'-0"S-5
D DETAIL - MOMENT CONNECTION
_ 3" = 1'-0"
4 SECTION - MOMENT CONNECTION
4 4
_ 3" = 1'-0"
5 SECTION - MOMENT CONNECTION
_ 3" = 1'-0"
G DETAIL - TYPICAL CAP PL CONNECTIONS
6 6
SECTION 6-6
ALTERNATE DETAIL
6 6
T
(2
M A
X
T /4
1/4" MAX
TOOLED OR SAW CUT JOINT,
FILL W/ BACKER ROD & SEALANT
CONC SLAB
T = SLAB THICKNESS
#4@12 DOWELS
AT PERIMETER
DIMENSIONS OF PAD AS REQD TO SUIT
EQUIP (4" MIN HEIGHT UNLESS PAD
#4@12
EW
BASE PLATE BY
EQUIP MFR
MIN 1" GROUT
GROUTED SLEEVE
ANCHOR BOLT SIZE,
NUMBER AND LOCATION
TO BE SUPPLIED
/3
L E
N G
T H
(6
M A
X
L E
N G
T H
A S
R E
Q D
B Y
E Q
U
IP
M F
R O
R M
IN
W H
IC
H
E V
E R
I S
G R
E A
T E
R
BEND AS REQD
IS CAST INTEGRALLY WITH SLAB)
12" MIN
(TYP)
C ANCHOR BOLTL
3" MIN
BY EQUIP MFR
WATERPROOFING
WHERE APPLICABLE
T/ EQUIP PAD
TOP OF SLAB OR FNDN
CONC STRUC ELEMENT
N E
W I
N F
IL
L
W A
L L
E X
IS
T
W A
L L
HOHMANN & BARNARD PTA 420 ANCHOR
(GALV) @ 32" OC, CONN TO EXIST LINTEL
BOND BM W/ 2-#4 AT TOP OF WALL
#4@16 VERT REINF IN GROUTED CORES
9 GA HOR JT REINF @ 16" OC, UNO
(ATTACH INTO EXIST CMU WALL W/
9 GA WIRE ANCHORING SYSTEM)
BOND BM W/ 1-#4
VERT DWL. MATCH SIZE & SPACING OF VERT
REINF IN WALL. EMBED 6" INTO EXIST CONC
W/ EPOXY ADHESIVE, UNO
BOND BM W/ 1-#4 AT TOP OF EACH GROUT
LIFT (TYP)
3"x3" MIN CUT MASONRY INSPECTION
& CLEANOUT HOLE AT REINF (REQD
FOR GROUT POUR HEIGHTS GREATER
THAN 4 FEET)
P R
O J
L A
P
G R
O U
T L
IF
T
G R
O U
T L
IF
T
P R
O J
L A
P
NEW CMU WALL, THICKNESS TO MATCH EXIST
END POSTAT HORIZONTAL SURFACE AT STAIR
CONTINUOUS
TOP RAIL
RAILS & POSTS
TOEBOARD
UON
GUARDRAIL POST
MOUNTING DETAIL
SEE DET J/-
WALKING
SURFACE
1.
/4
M A
X
TOEBOARD SHALL BE PROVIDED UNLESS SPECIFICALLY NOTED
OTHERWISE ON PLANS OR IN SPECS. TOEBOARD NOT REQUIRED
WHEN CONCRETE CURBS 4" OR HIGHER ARE PROVIDED.
UON
TOEBOARD
CONTINUOUS POST
AT MAX 3'-8" OC
SPACING TYP
AS SPECIFIED
RAILS & POSTS
TOP RAIL
CONTINUOUS
SURFACE
WALKING
1'-0"
(TYP)
2" (MIN)
E
Q U
A L S
P A
C E
S
1'-0" T
T = TYP TREAD LENGTH
CONTINUOUS POST
AT MAX 3'-8" OC
SPACING TYP
AS SPECIFIED
GUARDRAIL POST
MOUNTING DETAIL
SEE DET J/- (TYP)
4 1/2"
/2
C L
FIELD DRILL
HOLES IN ANGLE
FOR SST BOLTS
MOUNTING
BRACKET
1"
POST
2 1/2" (TYP)
CL
STL ANGLE
STL ANGLE
C L
2 1/2" (TYP)
/2
STL ANGLE
POST
4 1/2"
LC
MOUNTING
BRACKET -
WELDED TO PIPE
SLEEVE
WELD 1/4"
CLOSURE
PLATE TO
SLEEVE
CLOSE FITTING PIPE
SLEEVE MAX I.D. = O.D.
OF POST + 1/8"
FIELD DRILL
HOLES IN ANGLE
FOR SST BOLTS
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated0 /2
/2
:4
:2
A
M
RENOVATE FACILITY FOR AFE BUILDING 411G. HOLBROOK
B. BENNETT
J. ZANOTTI
SD-1
STANDARD DETAILS
DETAIL
1" = 1'-0"
F
TOOLED CONTROL JOINT
DETAIL
1" = 1'-0"
E
EQUIPMENT PAD
DETAIL
1/2" = 1'-0"
A
TYPICAL CMU WALL REINFORCING
DETAIL
1" = 1'-0"
B
GUARDRAIL
DETAIL
1" = 1'-0"
C
SIDE MOUNTED GUARDRAIL
DETAIL
1" = 1'-0"
D
REMOVABLE SIDE MOUNTED GUARDRAIL
1. HVAC EQUIPMENT, DUCTWORK AND PIPING SYSTEM LAYOUTS ARE DIAGRAMMATIC AND
INTENDED TO SHOW PIPING AND DUCT BASIS OF DESIGN. IF THE CONTRACTOR PROPOSES TO
FURNISH EQUIPMENT THAT REQUIRES AN ARRANGEMENT OR SPACE DIFFERING FROM THAT
INDICATED ON THE DRAWINGS OR SPECIFIED, THE CONTRACTOR SHALL PREPARE AND SUBMIT
TO THE ENGINEER FOR APPROVAL, DETAILED ARCHITECTURAL, STRUCTURAL, PLUMBING, HVAC
AND ELECTRICAL DRAWINGS AND EQUIPMENT LISTS SHOWING ALL NECESSARY CHANGES AND
EMBODYING ALL FEATURES OF THE EQUIPMENT HE PROPOSES TO FURNISH. THIS INFORMATION
SHALL INCLUDE BUT NOT BE LIMITED TO PLANS, SECTIONS, DETAILS, AND SCHEMATICS OF ALL
APPURTENANCES REQUIRED. SUCH CHANGES IF APPROVED BY THE ENGINEER SHALL BE AT
NO EXTRA COST TO THE OWNER. THE CONTRACTOR SHALL ASSUME THE COST OF, AND THE
RESPONSIBILITY FOR SATISFACTORILY ACCOMPLISHING ALL THE NECESSARY CHANGES
CORRESPONDING TO THE DIMENSIONS AND CHARACTERISTICS OF THE EQUIPMENT SUBMITTED
INCLUDING CHANGES TO ALL OTHER TRADES TO SATISFACTION OF ENGINEER. REFER TO
SPECIFICATIONS FOR FURTHER DETAILS.
2. THE CONTRACTOR SHALL PROVIDE A METHOD OF PROCEDURE PER THE REQUIREMENTS OF
SPECIFICATION SECTION 01040 AND A SCHEDULE PER THE REQUIREMENTS OF SPECIFICATION
SECTION 01050.
3. ALL WORK, INCLUDING BUILDING SERVICES AND UTILITY SHUTDOWNS, SHALL BE
COORDINATED AND SCHEDULED WITH THE OWNER PRIOR TO BEGINNING CONSTRUCTION.
4. THE CONTRACTOR SHALL REMOVE CONSTRUCTION DEBRIS AND ALL OTHER DEBRIS MADE
DURING THE WORK THEY HAVE COMPLETED, AT THE END OF EACH WORK DAY.
5. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGED EQUIPMENT, CEILING, WALLS,
ETC. WHICH HAVE BEEN DAMAGED BY THE WORK OF THIS PROJECT AT NO COST TO THE
OWNER.
6. NOTED ELEVATIONS ARE GIVEN AS REFERENCE FOR THE INTENDED ROUTING OF SYSTEMS.
THE CONTRACTOR SHALL COORDINATE THE EXACT ROUTING. ALL WORK SHALL BE INSTALLED
WITH THE PROPER PITCH. COORDINATE WITH OTHER TRADES AND FIELD CONDITIONS TO
AVOID INTERFERENCES.
7. ACCESS DOORS SHALL BE INSTALLED IN DUCTS ADJACENT TO ALL FIRE DAMPERS, SPLITTER
DAMPERS, CONTROL DEVICES, ETC. PROVIDE FIRE OR FIRE/SMOKE DAMPERS IN ALL DUCTS
WHICH PENETRATE FIRE-RATED WALLS OR FLOORS. PROVIDE AND COORDINATE ACCESS
DOORS IN DRYWALL WITH GENERAL TRADE.
8. DUCT TRANSITIONS SHALL BE A MINIMUM OF FOUR TO ONE RATIO.
9. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL DUCTS, GRILLES, DIFFUSERS, ETC.
WITH THE LIGHTS, BEAMS, PIPING, ETC. PRIOR TO FABRICATION OF DUCTWORK. COORDINATE
WORK WITH OTHER TRADES AND EXISTING CONDITIONS. CONTRACTOR SHALL PROVIDE
OFFSETS AND TRANSITIONS AS REQUIRED AT NO COST TO OWNER. EXPOSED DIFFUSERS,
DUCTWORK AND PIPING IN SHALL BE PAINTED. REFER TO SPECIFICATIONS.
10. CONTRACTOR SHALL PROVIDE ALL OPENINGS IN THE STRUCTURE REQUIRED FOR WORK.
REFER TO ROUTINGS SHOWN ON PLAN DRAWINGS.
11. EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE LOCATED OVER ELECTRICAL PANELS
OR THROUGH ELECTRICAL ROOMS.
12. COORDINATE ALL MOTOR SIZES, STARTERS, DISCONNECT SWITCHES, CONTROLS, ETC. WITH
ELECTRICAL CONTRACTOR PRIOR TO THE RELEASE OF ANY EQUIPMENT.
13. INSTALL TURNING VANES IN ALL 90° DUCT ELBOWS AND AT DUCT TEES. INSTALL AIR VOLUME
EXTRACTORS OR SPLITTER DAMPERS AT ALL BRANCHES TO MAIN DUCT CONNECTIONS.
14. ALL T-STATS SHALL BE MOUNTED IN LINE WITH CENTERLINE OF LIGHT SWITCH AT 48" A.F.F.
UNLESS OTHERWISE NOTED. VERIFY MOUNTING HEIGHT IS 48" PRIOR TO BALANCING SYSTEMS.
CONTRACTOR SHALL CALIBRATE ALL THERMOSTATS.
15. WHERE DUCTWORK AND PIPING PASS THROUGH RATED ASSEMBLIES THE CONTRACTOR
SHALL MAINTAIN INTEGRITY OF THE ASSEMBLIES USING U.L. APPROVED SEALING METHODS TO
MATCH RATING.
16. CONTRACTOR SHALL PROVIDE HIGH POINT VENTS AND LOW POINT DRAINS AS REQUIRED IN
FINAL ROUTING OF PIPING.
17. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
18. EXISTING GRADES, STRUCTURES, ELEVATIONS, PIPING AND UTILITIES ARE INDICATED IN
THEIR APPROXIMATE LOCATIONS ON THE PLANS; HOWEVER, THE INFORMATION IS NOT
GUARANTEED TO BE CORRECT AND/OR COMPLETE, HAVING BEEN PLOTTED FROM AVAILABLE
DRAWINGS, RECORDS AND SURVEYS. ALL SUCH DATA SHALL BE VERIFIED IN THE FIELD BY THE
CONTRACTOR PRIOR TO FABRICATION AND CONSTRUCTION. THE EXISTENCE OF STRUCTURES,
PIPING, ETC. WHICH ARE NOT SHOWN AND WHICH MAY BE ENCOUNTERED WILL NOT BE A BASIS
FOR A CLAIM FOR EXTRA WORK.
19. THE ELEVATIONS ARE BELIEVED TO BE REASONABLY CORRECT, BUT DO NOT PURPORT TO
BE ABSOLUTELY SO, AND ARE PRESENTED ONLY AS APPROXIMATIONS.
20. CONTRACTOR SHALL PROVIDE CONCRETE PADS FOR INSTALLED EQUIPMENT.
HVAC GENERAL NOTESHVAC SYMBOLS
MANUAL VOLUME DAMPER
COMBINATION
FIRE/SMOKE DAMPER
-1.5(1-1/2HR RATED)
MOTOR OPERATED
DAMPER
DIRECTION OF FLOW
DUCT SIZE-FIRST
NUMBER IS SIDE SHOWN
DUCT SECTION,
POSITIVE PRESS. FIRST
NUMBER IS TOP
DUCT SECTION,
NEGATIVE PRESS.
FIRST NUMBER IS TOP
ELEVATION CHANGE
(R) RISE, (D) DROP
ACCESS DOOR
FLEXIBLE CONNECTION
FLEXIBLE DUCT
DUCT LINING
TRANSITION
TURNING VANES
SIDE MOUNTED
DEVICE
BOTTOM MOUNTED
DEVICE
R
AD
12X20
20X12 16X8
20X12
20X12
12X20
VD
HUMIDISTAT
PRESS. DIFF. W/
INDICATOR LIGHT &
REMOTE ALARM @ ATC
THERMOSTAT
STATIC PRESSURE SENSOR
AIRFLOW SWITCH
TO SPACE
FROM SPACE
1" U
60 CFM
UNDERCUT DOOR
20X12 LD OR DG
200 CFM
LOUVER DOOR OR
DOOR GRILLE
U
FS
SP
T
PD
H
TYPICAL TAG
_ _ - _ _ _ - _ _ X _ _
M
SUPPLY AIR DIFFUSER
RETURN AIR GRILLE OR
EXHAUST AIR GRILLE
TRANSFER AIR GRILLE
GRILLE TYPE:
"R" = RETURN
"S" = SUPPLY
"T" = TRANSFER
"E" = EXHAUST
AIRFLOW IN CFM
SIZE
SIZE
ACCU
AD
AG
AHU
ALT
AP
ATC
AUTO
AUX
AVG
AIR COOLED CONDENSING UNIT
ACCESS DOOR
ABOVE GRADE
AIR HANDLING UNIT
ALTITUDE
ACCESS PANEL
AUTOMATIC TEMPERATURE CONTROL
AUTOMATIC
AUXILIARY
AVERAGE
A
BBD
BHP
BMS
BOT
BTU
BACK DRAFT SELF ACTING DAMPER
BRAKE HORSEPOWER
BUILDING MANAGEMENT SYSTEMS
BOTTOM
BRITISH THERMAL UNIT
B
CC CENTER TO CENTER
CENT CENTRIFUGAL
CL
CLG
COL
CTR
CENTER LINE
CEILING
COLUMN
CENTER
C
D TO DRAIN (NEAREST)
DG DOOR GRILLE
DIA DIAMETER
DISCH DISCHARGE
Ø DIAMETER
D
EUH ELECTRIC UNIT HEATER
EA EACH/EXHAUST AIR
EF EXHAUST FAN
ENT ENTERING
ELEC ELECTRICAL
ELEV ELEVATION
EMERG EMERGENCY
EXH EXHAUST
E
F FAHRENHEIT
FC FLEX CONNECTION
FD
FLR
FOB
FOT
FPVRT
FS
FIRE DAMPER/FLOOR DRAIN
FLOOR
FLAT ON BOTTOM
FLAT ON TOP
FAN POWERED VARIABLE VOLUME REHEAT
FLOW SWITCH
F
GA GAUGEG
HOA HAND OFF AUTO
HVAC HEATING VENTILATING & AIR
CONDITIONING
HZ HERTZ
H
ID INSIDE DIAMETER
IN INCHES
INSTR INSTRUMENT(ATION)
I
LAT LEAVING AIR TEMPERATURE
LBS
LWT
LVG
POUNDS
LEAVING WATER TEMPERATURE
LEAVING
L
M MOTOR
M
MBH THOUSAND BTU PER HOUR
MATL
MAX
MCA
MECH
MFR
MIN
MISC
MOCP
MATERIAL
MAXIMUM
MINIMUM CIRCUIT AMPACITY
MECHANICAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MAXIMUM OVER CURRENT PROTECTION
NC
NORMALLY CLOSED/ NOISE RATING
N NO
NORMALLY OPEN
NOM NOMINAL
NPT AMERICAN NATIONAL TAPER
PIPE THREAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OPP OPPOSITE
O
PH PHASE
PSI POUNDS PER SQUARE IN
PSIA PSI ABSOLUTE
PSIG PSI GAUGE
P
RA RETURN AIR
RF RETURN AIR FAN
REG REGISTER
RH RELATIVE HUMIDITY
RLA RUNNING LOAD AMPS
R
SA SUPPLY AIR
SD SUPPLY AIR DIFFUSER
SF SUPPLY AIR FAN
SCH SCHEDULE
SP STATIC PRESSURE
SPEC SPECIFICATION
SS STAINLESS STEEL
S
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE
TOS TOP OF STEEL
TXV THERMAL EXPANSION VALVE
T
U HEAT TRANSFER COEFFICIENT
UH UNIT HEATER
UL UNDERWRITERS LABORATORY
U
V VOLTS
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VRT VARIABLE VOLUME REHEAT
V
W/ WITH
W/O WITHOUT
WB WET BULB
W
HVAC ABBREVIATIONS
DB DRY BULB
DWG DRAWING
DX DIRECT EXPANSION COIL
CO CLEAN OUT
EAT ENTERING AIR TEMPERATURE
LV LOUVER
LRA LOCKED ROTOR AMPS
APD AIR PRESSURE DROP
ESP EXTERNAL STATIC PRESSURE
KW KILOWATTSK
OAT OUTSIDE AIR TEMERATURE
SENS SENSIBLE
WG WATER GAUGE
RPM REVOLUTIONS PER MINUTE
MCC MOTOR CONTROL CENTER
MTD MOUNTED
RG RETURN GRILLE
NOTE:
THIS IS A GENERAL LIST OF SYMBOLS AND
ABBREVIATIONS. NOT ALL ITEMS ARE SHOWN
HERE APPEAR ON THE CONTRACT DRAWINGS.
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated4 /2
/2
:4 :3
P
M
RENOVATE FACILITY FOR AFE BUILDING 411S TASCARELLA
G LUISI
H-1
HVAC SYMBOLS, ABBREVIATIONS, NOTES
AND SCHEDULES
VAV BOXES W/ REHEAT SCHEDULE
TAG AREA SERVED ACTUAL CFM MAX CFM MIN CFM
INLET SIZE
(IN) MAX APD REHEAT kW
NUMBER OF
STEPS V/PH/Hz MANUFACTURER & MODEL
VAV-1 A-115,A-116 500 700 210 8 0.36 3 2 208/1/60 TITUS DESV 300 OX 8
VAV-2 A-114 950 1200 360 10 0.43 5 2 208/1/60 TITUS DESV 300 OX 10
VAV-3 A-113 300 300 90 5 0.40 1.5 2 208/1/60 TITUS DESV 300 OX 5
VAV-4 A-112 850 1200 360 10 0.43 5 2 208/1/60 TITUS DESV 300 OX 10
VAV-5 A-110 100 200 60 4 0.39 1 2 208/1/60 TITUS DESV 300 OX 4
1. PROVIDE FACTORY WIRING TO THE CONTROLS AND REHEAT
COIL.
AIR HANDLING UNIT SCHEDULE
UNIT AREA SERVED CFM
MINIMUM OA
CFM TYPE
SUPPLY FAN COOLING SECTION HEATING SECTION ELECTRICAL
FILTER TYPE
SIZE WEIGHT (LBS)
MANUFACTURER
& MODEL REMARKSFAN TYPE ESP. IN WG
FAN SPEED
RPM BHP MOTOR HP COIL TYPE NOM. TONS
NET COOLING CAPACITY EAT (°F) LAT (°F)
OAT (°F)
NUMBER OF
COMPRESSORS
COMPRESSOR
TYPE
NUMBER OF
CONDENSER
FANS
REFRIGERANT
TYPE INPUT KW STAGES EAT (°F) LAT (°F) MCA MOCP V/PH/HzTOTAL MBH SENS MBH DB WB DB WB
RTU-1 A-111,A-112,A-113,A-114,
A-115,A-116
2700 255 ROOFTOP PLENUM 1.50 1768 1.75 2 CU/AL 6 75.5 63.8 76.9 63.4 54.7 53.6 95 1 MODULATING 1 R410A 15 2 63.4 81.0 61 70 208/3 2" MERV 8 860 AAON RN-006 1,2,3,4,5,6,7,8,9,10,11,12,13, 14,15
NOTES:
1. PROVIDE 6" HIGH ROOF CURB.
2. PROVIDE STAINLESS STEEL DRAIN PAN.
3. CONDENSING UNIT IS REMOTE OUTDOORS. DX COOLING TO 35 F.
4. PROVIDE INDEPENDENT REFRIGERATION CIRCUIT FOR EACH COMPRESSOR WITH INTERTWINED EVAPORATOR COILS IF MULTIPLE COMPRESSORS.
5. DIGITAL SCROLL COMPRESSORS.
6. PROVIDE ELECTRIC HEATING WITH 2 STAGES OR SCR CONTROLLER.
7. PROVIDE EC MOTOR OR VFD CONTROL FOR SUPPLY FAN.
8. MOUNT SUPPLY FAN ON 1 INCH DEFLECTION SPRING ISOLATORS.
9. PROVIDE SINGLE POINT POWER CONNECTION WITH FACTORY PROVIDED, INTEGRAL, NON-FUSED DISCONNECT SWITCH.
10. PROVIDE AIR SIDE ECONOMIZER CONTROL WITH DUAL ENTHALPY SENSORS.
11. DOUBLE WALL 2" THICK INSULATED CABINET.
12. PROVIDE FACTORY MOUNTED, WIRED AND TESTED DDC CONTROL PANEL, SENSORS, AND CONTROLLED DEVICES WITH GATEWAY TO INTERFACE WITH THE BUILDING'S DDC SYSTEM.
13. PROVIDE FACTORY MOUNTED AND WIRED SMOKE DETECTOR AT SUPPLY AIR AND RETURN AIR CHAMBERS WITH AUXILIARY CONTACTS FOR SIGNAL TO FIRE ALARM PANEL.
14. DX HOT GAS REHEAT COIL FOR DEHUMIDIFICATION MODE.
15. RETURN AIR TEMPERATURE/ HUMIDITY SENSOR AND DISCHARGE AIR SENSOR.
SPLIT SYSTEM AIR HANDLING UNIT SCHEDULE
TAG AREA SERVED
AIRFLOW FAN COOLING COIL HEATING COIL
V/PH/Hz BASIS OF DESIGN REMARKS
TOTAL CFM MIN OA TYPE ESP(IN WG) MOTOR
CAPACITY EAT LAT REFRIGERANT
TYPE
KW
HEAT COIL
EAT
HEAT COIL
LATTOTAL MBH SENS MBH DB(°F) WB(°F) DB(°F) WB(°F)
AHU-1 A-110 390 0 INTEGRAL 0.30 30W 12.0 10.3 75.0 62.5 55.0 54.0 R410A - - - 208/1/60 MITSIBISHI PKA-A126A
PUY-A12NHA
AIR COOLED CONDENSING UNIT SCHEDULE
Mark SERVES
TOTAL
CAPACITY
(MBH) REFRIG. TYPE
REFRIG. SAT.
COND. TEMP. (F)
CAPACITY
(MBH)
AMB. AIR TEMP.
NO. OF
CIRCUITS
COMPRESSORS COMPRESSOR FAN MOTORS ELECTRICAL
MANUFACTURER & MODEL REMARKSMAX. MIN. NO. LRA EACH RLA EACH NO.. RPM HP EACH V/PH/Hz MCA
ACCU-1 AHU-1 NOM. 1 TON R410A 50 12.0 95 35 1 1 - 12 1 - - 208/1/60 13 MITSUBISHI - PUY-A12NHA 3
ACCU-2 AHU-2 NOM. 6 TON R410A 50 65.3 95 35 1 1 - 16.9 1 1140 0.33 208/3/60 24 AAON CFA-006 1,2
DIFFUSER SCHEDULE
MARK SERVICE TYP E SIZE INLET (IN) MAX CFM MAX- APD NC MANUFACTURER MODEL #
SD-1 SUPPLY LAY-IN 24"X24" 6 100 0.1 17 TITUS TDCA
SD-2 SUPPLY LAY-IN 24"X24" 8 200 0.1 21 TITUS TDCA
SD-3 SUPPLY LAY-IN 24"X24" 10 335 0.1 22 TITUS TDCA
RG-1 RETURN LAY-IN 24"X24" 6 100 0.1 17 TITUS TDCA
RG-2 RETURN LAY-IN 24"X24" 8 200 0.1 20 TITUS TDCA
RG-3 RETURN LAY-IN 24"X24" 10 320 0.1 22 TITUS TDCA
RG-4 RETURN LAY-IN 24"X24" 12 500 0.1 24 TITUS TDCA
NOTES:
1. SINGLE POINT POWER NON-FUSED DISCONNECT.
2. 115VAC CONVEINIENCE OUTLET- FACTORY WIRED.
3. ACCU-1 PROVIDES POWER TO AHU-1.
AHU-2
NOTES:
1. AHU-1 IS POWERED FROM ACCU-1
A B C D E F
4.9
F1
MENS
E-104
MENS LOCKER
ROOM
E-105
MECHANICAL
ROOM
E-106
PARTS CLEANING
E-107
BREAK/TRAINING
E-108
Unoccupied
E-109
VEST
E-110
JC
E-111
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
R1-200-12X6
R1-200-12X6 S1-200-8
1 2
S1-200-8
1 2
E1-125-8X8
S1-100-6
U
25 CFM
U
50 CFM
1 2
E1-325-10X10
S1-250-10
R1-300-12X8
S2-300-12X8
S1-170-8
R2-0-24X24
R2-800-14X12
1 2
T2-170-18X18
S1-440-10
S1-440-10
3U
80 CFM
4 E1-50-6X6
1 2
T1-75-8X8
1 MEASURE EXISTING AIRFLOWS FOR ALL
SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR
PRIOR TO DEMOLITION AND SUBMIT TO
CONTRACTING OFFICER FOR USE AFTER NEW
WORK IS INSTALLED. THIS PLAN DOES NOT
SHOW ALL GRILLES. BALANCER SHALL LOCATE
AND RECORD ALL EXISTING FLOWS AS PART OF
ESTABLISHING EXISTING CONDITIONS.
EXISTING GRILLE TO REMAIN. AIR FLOWS
INDICATED ARE LAST KNOWN AIR FLOWS AND
SHALL BE INCLUDED ON BALANCING REPORT
FOR EXISTING CONDITIONS PRIOR TO
DEMOLITION. NOT ALL DEVICES ARE SHOWN,
HOWEVER BALANCER SHALL LOCATE AND
RECORD ALL DEVICES.
AIRFLOW SHOWN IS ASSUMED TO BALANCE
ROOM.
BALANCER SHALL LOCATE AND MEASURE
PRESUMED GRILLE IN THIS AREA AND RECORD
AIRFLOW ON BALANCING REPORT FOR
EXISTING CONDITIONS.
EXISTING PARTS CLEANING HOOD AND FAN
ASSUMED TO BE ABANDONED IN PLACE WITH
DORMANT RETURN GRILLE AT CEILING TO
REMAIN.
KEYED NOTES
DRAWING NO.BASE CIVIL ENG.CHIEF ENG. FLIGHT PLATE
SCALE:DATE:PROJECT NO:CHIEF CE OPERATIONS
USING AGENCY
COMMUNICATIONS
BIO ENVIRONMENTAL
ENVIRONMENTAL ENG.
FIRE
SAFETY
SECURITY
ANTI-TERRORISM
CDM SMITH PROJECT #
CHECK BY:
DRAWN BY:
DESIGN BY:
REV. NO. DATE DESCRIPTION BY
REVIEW
COORDINATION DATE
SHEET OF
ISSUE FOR CONSTRUCTION
FOR OFFICIAL USE ONLY
U.S. AIR FORCE
911TH AIRLIFT WING
PITTSBURGH INTERNATIONAL AIRPORT, ARS
MOON TOWNSHIP, PA 15108-5000:
54321 6
B
C
D
E
A
C
D
E
106718-223621
JLSS-16-0014 04/30/2018
GTP 210-168
503 Martindale Street, Suite 400 Pittsburgh, PA 15212-5722 Tel: (412) 201-5500
As indicated4 /2
/2
:4 :4
P
M
RENOVATE FACILITY FOR AFE BUILDING 411S TASCARELLA
G LUISI
Checker
H-2
HVAC PLAN - EXISTING
3/16" = 1'-0"
1 HVAC FLOOR PLAN - EXISTING
N
3/16" = 1'-0"
10'6'2' 4'
SCALE:
SEWING
FABRICATION
A-109
OXYGEN TESTING
A-108
BREAK ROOM
A-107
EXISTING
MECHANICAL
E-106
NVG TESTING
A-105
MEN'S
A-104
WOMEN'S
A-102
NVG HELMET
STORAGE
A-101
CLASSROOM
TRAINING
A-112
CHEM WARFARE
TESTING
A-113
PARACHUTE
ROOM
A-114
MANAGER
A-116
VESTIBULE 'B'
A-104A
VESTIBULE 'A'
A-102A
HIGH BAY
A-100
U
15 CFM
U
60 CFM
U
15 CFM
U
30 CFM
U
30 CFM
U
15 CFM
OFFICE
A-115
SKL ROOM
A-110
DATA
A-111
JANITORS
A-103
U
45 CFM
U
60 CFM
V A
V
-2 VAV-3
VAV-4
VAV-5
SD-2
8" NECK
120 CFM
TYP OF 3
SD-2
8" NECK
150 CFM
RG-2
8" NECK
135 CFM
RG-3
10" NECK
320 CFM RG-4
12" NECK
445 CFM
TYP OF 2
SD-2
8" NECK
160 CFM
TYP OF 6 RG-3
10" NECK
285 CFM
SD-2
8" NECK
150 CFM
TYP OF 2
SD-3
10 " NECK
215 CFM
TYP OF 4
SD-1
6 "
100 CFM
RG-4
12" NECK
365 CFM
TYP OF 2
RG-1
6" NECK
85 CFM
A B C
D E F
AHU-1
ACCU-1
VAV-1
10"x8"
"x
10"x8"
"x
14"x12"
10"ø
14"x14"
14"x14"14"x16"
8"ø
10"ø
10"ø
6"x6"
8"x14"
6"x12"
8"ø
14"x14" 16"x14"
"x
12"x16"
6"x12"
8"ø
8"x14"
12"ø
12"x8"
10"ø
8"ø
8"x12"
8"ø
8"ø 6"x12"
10"ø
8"ø 8"ø
8"x12" 6"x12" 8"ø
8"ø
BOTTOM TAP
5"ø
10"ø
8"ø
30" X 14" SA TO ABOVE.
TRANSITION TO AHU-2.
30" X 14" RA TO ABOVE.
TRANSITION TO AHU-2.
10"x14"
16"x12"
10"x12"
10"ø
10"ø
REQUIRED
CLEARANCE (TYP)
ACCU-2
8"ø
CONCRETE PAD WITH EQUIPMENT
RAILS. COORDINATE WITH
ARCHITECTURAL. SEE DETAIL B ON H-5.
5 4
5 5
PROVIDE EQUIPMENT
RAILS. SEE DETAIL B ON H-5.
VD
VDVD
VD
VD
VD
VD
VD
VD
VD
VDVD VD
VD
VD
VD
VD VD
VD
VD
VD
VD
VD
VD
VD
VD
VD VD
VD
VD
VD
VD
T
T
T
T
T T
SP
S1-250-10
R2-250-10
T2-170-18X18
S1-240-10
R2-240-14X12 R2-600-12X12
S1-300-10 S1-300-10
1 COORDINATE WITH ELECTRICAL DRAWINGS
FOR LOCATION OF HVAC EMERGENCY SHUT
OFF SWITCH.
RE-BALANCE EXISTING GRILLE TO MATCH
AIRFLOW PRIOR TO DEMOLITION.
GRILLE LOCATION NOT SHOWN. RE-BALANCE