Atch_2_Conceptual_Design.pdf
PDF 30 KB Posted
- Attached to
- USAFE RAB MSA B2748-2753 IDS Federal contract opportunity
- Solicitation number
- FA5641-17-T-0010
About this file
Atch 2 Conceptual Design
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Brand_Name_J&A_Redacted.pdf | ||
| Atch_3_DD254.pdf | ||
| FA5641-17-T-0010_RAB_MSA_2748-2753_IDS_Comb_Syn_&_Sol.pdf | ||
| Atch_1_Statement_of_Work.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
October 2016
Buildings 2748, 2750, 2751, 2752, 2753
Ramstein Air Base MSA Device Layout
Conceptual IDS Installation Design Package
SIZE FSCM NO DWG NO REV
F 1
SCALE NTS SHEET 1 of 4
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
Legend
IDS Enclosure
Arming Control Unit
Curtain PIR
Power Panel
BMS
Fiber Enclosure
B B
A A
Groud Bar
Existing Wood Mounting Board
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
October 2016
Buildings 2748, 2750, 2751, 2752, 2753
Ramstein Air Base MSA Elevations
Conceptual IDS Installation Design Package
SIZE FSCM NO DWG NO REV
F 1
SCALE NTS SHEET 2 of 4
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
Elevation A-A
E xi st in g P ow er
C on du it an d
P ow er O ut le t
D oo r F ra m e
New Curtain PIR to cover Entire Entry (both doors)
E xi st in g C on du it
E xi st in g E m pt y C on du it go in g up to th e ce ili ng
Existing Copper Enclosure
Existing Fiber
Enclosure
12 SMFOC
To
B2749/B2288
IDS Enclosure Panel
ACU
Door
*No cover
Existing Empty Conduit along the ceiling
Back Exhaust Vent
Ceiling
New Curtain PIR to cover the back and the exhaust vent
Elevation B-B
Floor
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
October 2016
Buildings 2749
Ramstein Air Base MSA Device Layout
Conceptual IDS Installation Design Package
SIZE FSCM NO DWG NO REV
F 1
SCALE NTS SHEET 3 of 4
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
Legend
IDS Enclosure
Arming Control Unit
Curtain PIR
Power Panel
BMS
Fiber Enclosure
D D
C C
Groud Bar
Existing Wood Mounting Board
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
October 2016
Buildings 2749
Ramstein Air Base MSA Elevations
Conceptual IDS Installation Design Package
SIZE FSCM NO DWG NO REV
F 1
SCALE NTS SHEET 4 of 4
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
Elevation C-C
E xi st in g P ow er
C on du it an d
P ow er O ut le t
D oo r F ra m e
New Curtain PIR to cover Entire Entry (both doors)
E xi st in g C on du it
E xi st in g E m pt y C on du it go in g up to th e ce ili ng
Existing Copper Enclosure
Existing Fiber
Enclosure
72 SMFOC
to B2288
IDS Enclosure Panel
ACU
Door
*With cover
Existing Empty Conduit along the ceiling
Back Exhaust Vent
Ceiling
New Curtain PIR to cover the back and the exhaust vent
Elevation D-D
Existing Various Router / Wireless
Equipment
1-12 2288 to 2748 (1-12) 13-24 2288 to 2749 (1-12) 25-36 2288 to 2750 (1-12) 37-48 2288 to 2751 (1-12) 49-60 2288 to 2752 (1-12) 61-72 2288 to 2753 (1-12)