Drawings PH 2.pdf
PDF 4 MB Posted
- Attached to
- REPLACEMENT OF DORM SURVEILLANCE SYSTEM Federal contract opportunity
- Solicitation number
- FA480920Q0065
About this file
This is a combined synopsis/solicitation for a small business set-aside contract to replace the dormitory surveillance system at Seymour Johnson Air Force Base in North Carolina. The solicitation requests quotes for installing new cameras and digital video recorders in multiple dorm buildings in accordance with attached drawings and statements of work. Quotes are due by September 3, 2020 and must include a price exhibit listing unit prices for line items and a technical exhibit demonstrating compliance with specifications and providing an installation plan. Evaluation will assess price and technical acceptability of offers. The awarded firm must register in required systems and accept payment by electronic funds transfer.
View the file
Other files for this federal contract opportunity
Show all 33
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
10 9
B
C
D
8 7 6
E
F
G
H
10 9 8 7 6
45 3 2 1
PROJECT NUMBER
SHEET
DRAWN BY
DRAWING NUMBER
SCALE
DATE
A
B
C
D
45 3
F
G
U
2 1
H
E
VKAG 11-1084P2
REPAIR DORM CAMERAS PHASE 2
VKAG 11-1084P2
R E
P A
I R
D
O R
M
C
A M
E R
S
P
H A
E
L O
C A
T I O
N
P
L A
N
G-1
CENME
30 JUL 12
1" = 800'
LOCATION PLAN
SCALE: 1"=800'
FINAL DETERMINATION REVEALS NO PRIME OR UNIQUE
FARMLAND ON THE BASE
NOTE
BASE CONTRACTING
BASE CIVIL ENGINEER
GATE 2 (BACK GATE)
CONTRACTOR'S
STORAGE AREA
GATE 1 (MAIN GATE)
VISITOR'S CENTER
MAG. VAR
. 9°-22'W
JUN 11
N
PROJECT LOCATION
DRAWING INDEX
DWG NO SHT NO DESCRIPTION
G-1 1 LOCATION PLAN
E-1 2
FLOOR PLAN BLDG 3605, 3607, 3613, 3614, 3615
E-2 3 FLOOR PLAN BLDG 3606
E-3 4 FLOOR PLAN BLDG 3616
HAUL ROUTE
1245 3
T
R
F
U
B
T
A P
P R
V D
D A
T E
I
T
S
R
O
F
U
G
D E
S C
R I P
T I O
N R
E V
F
E
H
D
C
B
P R
O J E
C T
T
L E
D R
A W
I N
G
S
H E
N
M
E
SCALE
DATE
T H
U N
I T
A
T E
S
A
F
R
C
V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S E
Y M
O U
R
J O
H N
S O
N
A
R
B
S
E
N
O R
R
O L I N
A
SHEET
DRAWN BY
OF
PROJECT NUMBER
245 3
DRAWING NUMBER
A
678910
G
F
E
H
D
C
B
678910
V:\PROJECTS\FY-11\vkag 11-1084p2\VKAG 11-1084P2_E-1.dwg
P A
R
M
C
A M
E R
A
L O
A
N
B
L D
G
30 JUL 12
1/8"=1'-0"
CEPT
E-1
VKAG 11-1084P2
N
MAG. VAR. 9°-22'W
JUN '11
8'
8'
1/8"=1'-0"
4' 16'
BLDG 3605, 3607, 3613, 3614, 3615
SECOND AND THIRD FLOOR
BLDG 3605, 3607, 3613,
3614, 3615 FIRST FLOOR
NEW CAMERA LOCATIONS
EXISTING CAMERA LOCATIONS
DIGITAL VIDEO RECORDER LOCATION
104102 106 108 110 112
101 103 105 107 109 111 125
126 128
130 132 134
131 133 135
202 204 206 208 210 212
201 203 205 207 209 211
224 226 228 230 232
225 227 229 231
STORAGE
LAUNDRY
C O
R R
I D
O R
MECH ROOM
STOR.
DAY ROOM
CORRIDOR
TELE
STORAGE
LAUNDRY
STORAGE MECH ROOM
C O
R R
I D
O R
STORAGE
DAY ROOM
MAIL ROOM
CORRIDOR
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
214 216
213 215
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
JAN.
STOR.
JAN.
116 118
ALL CONDUIT SHALL BE CONCEALED AND NOT EXPOSED
TO PUBLIC VIEW
EACH DORMITORY BUILDING HAS THREE (3) FLOORS
WHERE WORK IS TO BE COMPLETED
T
R
F
U
B
T
A P
P R
V D
D A
T E
I
T
S
R
O
F
U
G
D E
S C
R I P
T I O
N R
E V
F
E
H
D
C
B
P R
O J E
T
L E
D R
A W
I N
G
S
H E
M
E
SCALE
DATE
T H
U N
I T
A
T E
S
A
R
C
V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S E
Y M
O U
R
J O
H N
S O
N
A
R
S
E
N
O R
R
O L I N
A
SHEET
DRAWN BY
OF
PROJECT NUMBER
245 3
DRAWING NUMBER
A
678910
G
F
E
H
D
C
B
678910
A
P R
O J E
A
S E
C O
N T
R A o
V:\PROJECTS\FY-11\vkag 11-1084p2\VKAG 11-1084P2 E-2 3606.dwg
T A
K
D
P A
R
M
C
A M
E R
A
L D
G
F L O
A
N
30 JUL 12
1/8"=1'-0"
CENME
E-2
VKAG 11-1084P2
BLDG 3606 FLOOR PLAN
SECOND AND THIRD FLOOR
BLDG 3606 FLOOR PLAN
FIRST FLOOR
N
MAG. VAR. 9°-22'W
JUN '11
8'
8'
1/8"=1'-0"
4' 16'
LAUNDRY
OFFICE
STORAGE
MECH.
RM
DAY
ROOM
CORRIDOR
JAN.
STORAGE
STORAGE
STORAGE
CORRIDOR
TELECOM
122A
SPRINKLER
RISER RM
122B
CORRIDOR
STORAGE
LAUNDRY
DAY
ROOM
CORRIDOR
JAN.
MECH.
RM
STORAGE
TELECOM
STORAGE
NEW CAMERA LOCATIONS
EXISTING CAMERA LOCATIONS
ALL CONDUIT SHALL BE CONCEALED AND NOT EXPOSED
TO PUBLIC VIEW
EACH DORMITORY BUILDING HAS THREE (3) FLOORS
WHERE WORK IS TO BE COMPLETED
EXISTING EXTERIOR CAMERA LOCATIONEXISTING EXTERIOR CAMERA LOCATION
DIGITAL VIDEO RECORDER LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
T
R
F
U
B
T
A P
P R
V D
D A
T E
I
T
S
R
O
F
U
G
D E
S C
R I P
T I O
N R
E V
F
E
H
D
C
B
P R
O J E
T
L E
D R
A W
I N
G
S
H E
M
E
SCALE
DATE
T H
U N
I T
A
T E
S
A
R
C
V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S E
Y M
O U
R
J O
H N
S O
N
A
R
S
E
N
O R
R
O L I N
A
SHEET
DRAWN BY
OF
PROJECT NUMBER
245 3
DRAWING NUMBER
A
678910
G
F
E
H
D
C
B
678910
A
P R
O J E
A
S E
C O
N T
R A
V:\PROJECTS\FY-11\vkag 11-1084p2\VKAG 11-1084P2_E-3.dwg
T A
K
D
P A
R
M
C
A M
E R
A
L O
A
N
B
L D
G
30 JUL 12
1/8"=1'-0"
CENME
E-3
VKAG 11-1084P2
8'
8'
1/8"=1'-0"
4' 16'
MAG. VAR. 9°-22'W
JUN '11
N
BUILDING 3616
FIRST FLOOR PLAN
BUILDING 3616
SECOND AND THIRD FLOOR PLAN
OFFICE
WEIGHT ROOM
LAUNDRY
MECH. RM.
STORAGE
RISER/
SPRINKLER
COMM RM
STORAGE
DAY ROOM
LAUNDRY
MECH. RM.
COMM/
SPRINKLER
EXISTING EXTERIOR CAMERA LOCATION
DIGITAL VIDEO RECORDER LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
DIGITAL VIDEO RECORDER LOCATION
EXISTING EXTERIOR CAMERA LOCATION
NEW CAMERA LOCATIONS
EXISTING CAMERA LOCATIONS
104102 106 108 110 112
101 103 105 107 109 111
126 128
130 132 134
131 133 135
204 206 208 210 212
201 203 205 207 209 211
224 226 228 230 232
223 225 227 229
ALL CONDUIT SHALL BE CONCEALED AND NOT EXPOSED
TO PUBLIC VIEW
EACH DORMITORY BUILDING HAS THREE (3) FLOORS
WHERE WORK IS TO BE COMPLETED
| 1 VKAG 11-1084P2_G-1 - LOCATION PLAN AND DRAWING INDEX |
| 2 VKAG 11-1084P2_E-1 - TYPICAL DORMITORY FLOOR PLAN |
| 3 VKAG 11-1084P2_E-2 - TYPICAL FLOOR PLAN- BUILDING 3606 |
| 3 VKAG 11-1084P2_E-3 - TYPICAL FLOOR PLAN- BUILDING 3616 |
File details come from the government source that posted it. Updated .