Attachment 4 -- Typical Dormitory Floor Plan.pdf
PDF 208 KB Posted
- Attached to
- REPLACEMENT OF DORM SURVEILLANCE SYSTEM Federal contract opportunity
- Solicitation number
- FA480920Q0065
About this file
This document is a combined synopsis/solicitation for a replacement of dormitory surveillance systems at Seymour Johnson Air Force Base in North Carolina. The Air Force is seeking quotes to provide and install a new surveillance camera system in five dormitory buildings, with three floors each requiring work. Quotes are due by September 3rd, 2020 and will be evaluated based on price and technical acceptability. This requirement has been set aside only for small businesses. Offerors must be registered in SAM and WAWF and provide their DUNS, CAGE code, and completed representations with their quote. A site visit is scheduled for August 26th. The work must be completed per the statement of work and as-built drawings provided. The contracting agency is the 4th Contracting Squadron at Seymour Johnson AFB.
View the file
Other files for this federal contract opportunity
Show all 33
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1245 3
H
T
R
F
U
B
T
A P
P R
V D
D A
T E
I
T
S
R
O
F
U
G
D E
S C
R I P
T I O
N R
E V
F
E
H
D
C
B
P R
O J E
C T
I T
L E
D R
A W
I N
G
S
H E
E
N
A M
E
SCALE
DATE
T H
U N
I T
D
S
A
T E
S
A
R
F
O R
C
V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S E
Y M
O U
R
J O
H N
S O
N
A
R
B
S
E
N
O R
R
O L I N
A
SHEET
DRAWN BY
OF
PROJECT NUMBER
245 3
DRAWING NUMBER
A
678910
G
F
E
H
D
C
B
678910
V:\PROJECTS\FY-11\vkag 11-1084p2\VKAG 11-1084P2_E-1.dwg
P A
D
R
M
C
A M
E R
P
A
L O
P
L A
N
B
L D
G
30 JUL 12
1/8"=1'-0"
CEPT
E-1
VKAG 11-1084P2
N
MAG. VAR. 9°-22'W
JUN '11
8'
8'
1/8"=1'-0"
4' 16'
BLDG 3605, 3607, 3613, 3614, 3615
SECOND AND THIRD FLOOR
BLDG 3605, 3607, 3613,
3614, 3615 FIRST FLOOR
NEW CAMERA LOCATIONS
EXISTING CAMERA LOCATIONS
DIGITAL VIDEO RECORDER LOCATION
104102 106 108 110 112
101 103 105 107 109 111 125
126 128
130 132 134
131 133 135
202 204 206 208 210 212
201 203 205 207 209 211
224 226 228 230 232
225 227 229 231
STORAGE
LAUNDRY
C O
R R
I D
O R
MECH ROOM
STOR.
DAY ROOM
CORRIDOR
TELE
STORAGE
LAUNDRY
STORAGE MECH ROOM
C O
R R
I D
O R
STORAGE
DAY ROOM
MAIL ROOM
CORRIDOR
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
214 216
213 215
EXISTING EXTERIOR CAMERA LOCATION
EXISTING EXTERIOR CAMERA LOCATION
EXISTING INTERIOR CAMERA LOCATION
JAN.
STOR.
JAN.
116 118
ALL CONDUIT SHALL BE CONCEALED AND NOT EXPOSED
TO PUBLIC VIEW
EACH DORMITORY BUILDING HAS THREE (3) FLOORS
WHERE WORK IS TO BE COMPLETED
File details come from the government source that posted it. Updated .