FA4809-10-R-0004
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
The purpose of this amendment is to incorporate changes to subject solicitation as shown below:
A. Delete Attachment 4, entitled, "Past Performance Questionnaire, FA4809-10-R-0001", 7 pages, and incorporate the attached revised Attachment 4, entitled "Past Performance Questionnaire, FA4809-10-R-0004," 7 pages.
B. At Attachment 5, Sample Project, delete Statement of Work For Repair Bldg. 3803 (VAQ), Project # VKAG 96-1105, 2 pages, page 4 of 6 and 5 of 6, dated 16 Jul 10, and incorporate the attached revised Statement of Work For Repair Bldg. 3803 (VAQ) Project # VKAG 96-1105, 2 pages, page 4 of 6 and 5 of 6, Dated 23Jul 10.
C. Reference Section B = Supplies or Services and Prices, NOTE 4: Revise to read as follows:
NOTE 4: Offeror's attention is invited to SF1442, Block 10, item 5. The maximum contract value/program value is the MAXIMUM value of the MACC ($45,000,000.00), not the value of each resultant contract awarded. (There is no stated maximum value for each contract awarded at this time). See Note 5 below. Each resultant awarded contract will have a first task order award in the guaranteed minimum amount of $2,000.00), which will be applied to a project later in the task order process of any future projects."
D. The following is added to Section B - Supplies or Services and Prices, as NOTE 5:
"NOTE 5: A Maximum value will be established for each resultant contract awarded against the Multiple Award Construction Contract (MACC) at the time of contract(s) award, which will be dependent on the number of contracts awarded. The value of all contracts awarded shall not exceed the MACC maximum contract value/program value of $45,000,000.00."
E. SF1442, Block 13A. The time and date for receipt of proposals is changed to 4:00 PM/27 Aug 2010.
F. All other terms and conditions remain unchanged.
(End of Summary of Changes)
| FA4809-10-R-0004 | |
| Attachment 5 |
Revised Statement of Work For
REPAIR BLDG. 3803 (VAQ)
Project # VKAG 96-1105
23 Jul 10 The contractor shall prepare a proposal to renovate Bldg. 3803 (VAQ). The building houses visiting airmen (billeting) to Seymour Johnson AFB. Specific requirements are as follows:
1. Repair VAQ, General
| a. | Design shall be in accordance with the AFSDG 4-724-01, Design: Visiting Quarters, the Seymour Johnson AFB Architectural Standards, Unified Facilities Criteria (UFC), National Fire Protection Association (NFPA) regulations, North Carolina Building Code, as well as those required elsewhere this document and in the MACC general requirements. |
| b. | Final facility interior square footage shall be as required by the regulations, requirements and standards and total identified funds. |
2. General requirements Demolish existing floor plan as required to create new floor plan IAW AFSDG 4-724-01, Design: Visiting Quarters (Satellite). Currently, the room layout has two guest rooms sharing one bathroom. There are six single rooms as well. All rooms must comply with the private bathroom guidance, ADA guidance and space requirements as well incorporating the support functions. All areas listed in AFSDG 4-724-01, Table 2-1, are not required. Areas currently in the existing facility are the only areas required: Guest Rooms, Mechanical Rooms, Storage Rooms, Laundry Rooms, Janitor Rooms, and Lounge Areas.
Replace all exterior windows. Replacements shall be IAW UFC 04-010-01, DoD Minimum Antiterrorism Standards for Buildings. Ensure existing structure meets requirements and modify as required.
| Add a brick masonry veneer to the exterior of the existing facility and tie existing | standing seam roof system into it as required. | ||
| Replace the entire HVAC system, entire electrical system (include all conduit, | wiring, light fixtures, etc), entire plumbing system (include all fixtures, | enclosures, etc), all doors/ frames/ hardware, and all ceiling/wall/floor finishes. |
Pg 4 of 6 Revised, Amendment 0003 Dated 23 Jul 10
| FA4809-10-R-0004 | |
| Attachment 5 |
Interior and Exterior lighting shall be per UFC 3-530-01.
Install power outlets throughout facility.
| Design temps shall be 68 (winter) and 75 (summer) degrees. | |||
| Ventilation per ASHRAE Standard 62 | |||
| Heating calculations to include losses due to conduction2 | |||
| , infiltration, and internal | loads. | ||
| Facility (first floor only) shall be in compliance with ADA requirements. | |||
| Existing roof is standing seam metal and new exterior shall tie in properly. | |||
| Install a new fire protection / detection system per UFC and NFPA. Suppression | system is required. | ||
| Add a new mass notification system, new interior signage, and new remote | electric meters. | ||
| Fire alarm panel to be located in mechanical room (utilize Monaco M-2 system or | compatible) | ||
| Install cable TV and Comm (Telephone and Data) outlets throughout facility. This | includes backboard with ground and power, conduit (with pull strings), boxes and | blank plastic plates. Contractor shall contract with Time Warner Cable for all cable | |
| TV | wiring and pay any associated costs to provide a complete functional system. |
Base Communications will wire all Comm (Telephone and Data).
| New electrical panels shall be 3 phase, 280V/120V, 42 circuit. The panels shall be fed | from a new 3 phase transformer (if existing does not have adequate capacity) sited by | the Contractor and minimum of 25’ from the facility. |
| Install valves at water service connections to mains. |
3. Support Information:
Existing sanitary sewer (SS) is 6” and is assumed adequate.
Existing water main (W) is 8" diameter with 4” and 2” services to building.
c. NATURAL gas is in the area.
Pg 5 of 6
| Revised, Amendment 0003 |
| Dated 23 Jul 10 |